SERIES: VGS-250B │ DESCRIPTION: AC-DC POWER SUPPLY
FEATURES
•
•
•
•
•
•
•
•
built-in cooling with temperature-controlled fan
+70°C operation
output trim
current/voltage/temperature protections
screw terminal interface
switch-selectable AC input range
low standby power consumption
30 mm height
MODEL
output
voltage
output
current
output
power
ripple
and noise1
efficiency2
(Vdc)
max
(A)
max
(W)
max
(mVp-p)
typ
(%)
VGS-250B-12
12
20.8
249.6
150
86.5
VGS-250B-24
24
10.5
252
150
89
VGS-250B-48
48
5.2
249.6
200
89.5
Notes:
1. 20 MHz bandwidth oscilloscope, 12” of twisted load cables paralleled with 0.1 µF ceramic and 47 µF electrolytic capacitors placed across the terminals at the load.
2. At 230 Vac, 50 Hz, full load.
3. All specifications are measured at Ta=25°C, nominal input voltage, and rated output load unless otherwise specified.
PART NUMBER KEY
VGS-250B - XX
Base Number
Output Voltage
cui.com
Additional Resources:
Product Page
|
3D Model
CUI Inc │ SERIES: VGS-250B │ DESCRIPTION: AC-DC POWER SUPPLY
date 05/02/2023 │ page 2 of 5
INPUT
parameter
voltage
conditions/description
min
typ
max
units
via input selector switch1
90
180
115
230
132
264
Vac
Vac
63
Hz
5
3
A
A
frequency
47
current
at 115 Vac, full load
at 230 Vac, full load
inrush current
at 230 Vac, cold start, full load
60
A
leakage current
at 240 Vac
2
mA
no load power consumption
at 230 Vac
0.75
W
Notes:
1. Input selector must be set to match input voltage or damage could occur.
OUTPUT
parameter
conditions/description
min
typ
line regulation
max
units
±0.5
%
±1
±0.5
%
%
load regulation
12 Vdc output model
all other models
adjustability
built in trim pot
start-up time
at 115/230 Vac, full load
1.5
s
rise time
at 115/230 Vac, full load
30
ms
hold-up time
at 115 Vac, full load
at 230 Vac, full load
±10
%
12
16
switching frequency
ms
ms
65
kHz
PROTECTIONS
parameter
conditions/description
min
max
units
over voltage protection
output shutdown, auto recovery
115
typ
150
%
over current protection
output shutdown, auto recovery
105
150
%
short circuit protection
output shutdown, auto recovery
over temperture protection
output shutdown, auto recovery
max
units
SAFETY & COMPLIANCE
parameter
conditions/description
isolation voltage
input to output for 1 minute, 10 mA
input to ground for 1 minute, 10 mA
output to ground for 1 minute, 10 mA
isolation resistance
input to output at 500 Vdc
input to ground at 500 Vdc
output to ground 500 Vdc
safety approvals
certified to 62368: EN
certified to 60950: IEC/UL
safety class
class I
conducted emissions
EN 55032:2015, Class A
radiated emissions
EN 55032:2015, Class A
voltage fluctuation and flicker
EN 61000-3-3:2013, Class A
ESD immunity
IEC 61000-4-2, air: ±8 kV; contact: ±4 kV, Class A
radiated field immunity
IEC 61000-4-3, 3 V/m, Class A
electrical fast transient
immunity
IEC 61000-4-4, Ac power port: 1 kV;
signal & telecommunication ports: 0.5 kV, Class B
Notes:
min
typ
1,500
1,500
500
100
100
100
Vac
Vac
Vac
MΩ
MΩ
MΩ
2. The power supply is considered a component which will be installed into final equipment. The final equipment still must be tested to meet the necessary EMC directives.
cui.com
Additional Resources:
Product Page
|
3D Model
CUI Inc │ SERIES: VGS-250B │ DESCRIPTION: AC-DC POWER SUPPLY
date 05/02/2023 │ page 3 of 5
SAFETY & COMPLIANCE (CONTINUED)
parameter
conditions/description
surge immunity
IEC 61000-4-5, input L to input N: 1 kV;
input L to FG: 2 kV; input N to FG: 2 kV, Class C
conducted immunity
IEC 61000-4-6, frequency range: 0.15~80 MHz;
field strength: 3 Vms, Class A
magnetic field immunity
IEC 61000-4-8, 1 A/m, Class A
voltage dips, interruptions
IEC 61000-4-11:
voltage dips >95% reduction, 0.5 period, Class A
voltage dips 30% reduction, 25 period, Class B
voltage dips >95% reduction, 250 period, Class C
MTBF
as per MIL-HDBK-217F, 25°C
RoHS
Notes:
min
typ
max
200,000
units
hours
yes
1. The power supply is considered a component which will be installed into final equipment. The final equipment still must be tested to meet the necessary EMC directives.
ENVIRONMENTAL
parameter
conditions/description
min
operating temperature
see derating curves
storage temperature
typ
max
units
-20
70
°C
-40
85
°C
operating humidity
non-condensing
20
90
%
storage humidity
non-condensing
10
95
%
DERATING CURVES
cui.com
Additional Resources:
Product Page
|
3D Model
CUI Inc │ SERIES: VGS-250B │ DESCRIPTION: AC-DC POWER SUPPLY
date 05/02/2023 │ page 4 of 5
MECHANICAL
parameter
conditions/description
dimensions
215 x 115 x 30
min
typ
max
units
mm
weight
1000
cooling
cooling fan
input/output connector
screw terminals accept 22~12 AWG wire, 1.2 N-m torque
g
MECHANICAL DRAWING
units: mm
tolerance: ±0.3 mm
I/P & O /P Connector
Input/Output Connector
1
+V
2
+V
3
+V
4
-V
5
-V
6
-V
7
FG
8
AC(N)
9
AC(L)
f
T r im
POT
+V
+V
+V
f
Function
PIN
-V
-V
-V
(F G )
AC(N)
A C (L)
Max Depth
Torque
M3X0.5