SERIES: VGS-25W │ DESCRIPTION: AC-DC POWER SUPPLY
FEATURES
•
•
•
•
•
•
•
wide input range (85 ~ 305 Vac)
available with conformal coating or terminal cover options
UL/EN/IEC 62368 certified
designed to meet IEC/EN 61558 system requirements
short-circuit, over-current, over-voltage protections
input over voltage category III design
CISPR/EN55032 Class B radiated/conducted emissions
RoHS
MODEL
output
voltage
output
current
output
power
ripple
and noise�
efficiency2
max
(A)
max
(W)
max
(mVp-p)
typ
(%)
typ
(Vdc)
range
(Vdc)
VGS-25W-3
3.3
2.85~3.6
6.0
19.8
100
78
VGS-25W-5
5
4.5~5.5
5.0
25.0
100
81
VGS-25W-12
12
10.8~13.2
2.1
25.2
100
85
VGS-25W-15
15
13.5~16.5
1.7
25.2
100
86
VGS-25W-24
24
22.0~27.6
1.1
26.4
100
87
VGS-25W-48
48
42.0~54.0
0.57
27.36
120
88
Notes:
1. Ripple & noise are measured at 20 MHz BW with 47 uF electrolytic and 0.1 uf ceramic capacitors on the output.
2. Measured at 230 Vac.
PART NUMBER KEY
VGS-25W - XX - X
Base Number
Output Voltage
cui.com
A - with terminal cover
B - with conformal coating
Additional Resources:
Product Page
|
3D Model
CUI Inc │ SERIES: VGS-25W │ DESCRIPTION: AC-DC POWER SUPPLY
date 09/09/2021 │ page 2 of 7
INPUT
parameter
conditions/description
min
max
units
voltage range
ac input
dc input
85
100
305
430
Vac
Vdc
47
63
Hz
0.6
0.34
A
A
frequency range
typ
current
at 115 Vac
at 230 Vac
inrush current
at 115 Vac, cold start
at 230 Vac, cold start
leakage current
at 277 Vac
0.5
mA
no load power consumption
48 V models, at 230 Vac
all other models, at 230 Vac
0.5
0.3
W
W
max
units
5,000
4,000
3,000
2,000
1,000
500
μF
μF
μF
μF
μF
μF
20
40
A
A
OUTPUT
parameter
conditions/description
min
typ
capacitive load
3.3 V models
5 V models
12 V models
15 V models
24 V models
48 V models
initial set point acuracy
3.3 V models, full load range
5 V models, full load range
all other models, full load range
line regulation
3.3 & 5 V models, rated load
all other models, rated load
±0.5
±0.5
±1
%
%
load regulation
3.3 & 5 V models, 0~100% load
all other models, 0~100% load
±1
±0.5
±2
±1
%
%
±3
±2
±1
%
%
%
switching frequency
65
kHz
start-up time
0.3
s
8
60
ms
ms
hold-up time
at 115 Vac
at 230 Vac
PROTECTIONS
parameter
conditions/description
min
over current protection
auto recovery
110
over voltage protection
3.3 V models, auto recovery, hiccup
5 V models, auto recovery, hiccup
12 V models, auto recovery, hiccup
15 V models, auto recovery, hiccup
24 V models, auto recovery, hiccup
48 V models, auto recovery, hiccup
short circuit protection
continuous, auto recovery, hiccup
typ
max
units
300
%
6.75
7.75
16.2
20.25
32.4
60.0
Vdc
Vdc
Vdc
Vdc
Vdc
Vdc
max
units
SAFETY & COMPLIANCE
parameter
conditions/description
isolation voltage