Additional Resources:
Product Page
|
3D Model
date
05/31/2023
page
1 of 5
SERIES: VGS-50W │ DESCRIPTION: INTERNAL AC-DC POWER SUPPLY
FEATURES
•
•
•
•
•
•
wide input range (85 ~ 305 VAC)
available with conformal coating or terminal cover options
UL/EN/IEC 62368 certified
designed to meet IEC/EN 61558 and IEC/EN 60335 system requirements
short-circuit, over-current, over-voltage protections
CISPR/EN55032 class B radiated/conducted emissions
MODEL
output
voltage
output
current
output
power
ripple
and noise1
efficiency2
(Vdc)
max
(A)
max
(W)
typ
(mVp-p)
typ
(%)
5
10
50
80
83
VGS-50W-12
12
4.2
50
120
86
VGS-50W-15
15
3.4
51
120
87
VGS-50W-24
24
2.2
52
150
88
VGS-50W-36
36
1.45
52
240
89
VGS-50W-48
48
1.1
52
240
90
VGS-50W-5
Notes:
1. Ripple & noise are measured at 20 MHz BW with 47 µF aluminum electrolytic capacitor and 0.1 µF ceramic capacitor on the output.
2. Measured at 230 Vac.
PART NUMBER KEY
VGS-50W - XX - X
Output Voltage
Base Number
cui.com
A - with terminal cover
B - with conformal coating
Additional Resources:
Product Page
|
3D Model
CUI Inc │ SERIES: VGS-50W │ DESCRIPTION: AC-DC POWER SUPPLY
date 05/31/2023 │ page 2 of 5
INPUT
parameter
conditions/description
min
max
units
voltage
ac input
dc input
85
120
305
430
Vac
Vdc
47
63
Hz
1.2
0.8
A
A
frequency
current
115 Vac
230 Vac
inrush current
115 Vac, full load, cold start
230 Vac, full load, cold start
leakage current
277 Vac
typ
30
60
no load power consumption
A
A
0.75
mA
0.5
W
max
units
8,500
2,000
1,500
1,000
470
220
μF
μF
μF
μF
μF
μF
OUTPUT
parameter
conditions/description
min
capacitive load
5 Vdc output
12 Vdc output
15 Vdc output
24 Vdc output
36 Vdc output
48 Vdc output
line regulation
full load
±0.5
%
load regulation
0% ~ 100%, 5 Vdc output
0% ~ 100%, other outputs
±1
±0.5
%
%
hold-up time
115 Vac, full load
230 Vac, full load
8
30
ms
ms
switching frequency
adjustability
built in trim pot
temperature coefficient
initial set point accuracy
5 V model
other models
typ
65
kHz
±10
%
±0.03
%
±2
±1
%
%
PROTECTIONS
parameter
conditions/description
over voltage protection
5 Vdc output, clamp, auto recovery
12 Vdc output, hiccup, auto recovery
15 Vdc output, hiccup, auto recovery
24 Vdc output, hiccup, auto recovery
36 Vdc output, hiccup, auto recovery
48 Vdc output, hiccup, auto recovery
min
over current protection
230 Vac, auto recovery
short circuit protection
continuous, auto recovery
typ
110
max
units
6.3
16.2
21.75
33.6
49.0
60.0
Vdc
Vdc
Vdc
Vdc
Vdc
Vdc
200
%
max
units
SAFETY & COMPLIANCE
parameter
conditions/description
isolation voltage
input to ground, 1 min.