Additional Resources:
Product Page
|
3D Model
date
09/09/2022
page
1 of 7
SERIES: VGS-600 │ DESCRIPTION: INTERNAL AC-DC POWER SUPPLY
FEATURES
•
•
•
•
•
•
•
•
•
•
•
•
UL/EN 62368 certified
active PFC
temperature range -40°C to +70°C
isolation up to 4000 Vac
operating altitude up to 5000 m
remote on/off
short-circuit, over-current, over-voltage & over-temperature protection
AC or DC input
internal fan cooling
PCB conformal coating
5 V, 1 A standby supply
remote output voltage sensing
MODEL
output
voltage
output
current
output
power
ripple
and noise1
efficiency2
(Vdc)
range
(Vdc)
max
(A)
max
(W)
typ
(mVp-p)
typ
(%)
VGS-600-12
12
11.8 ~ 12.6
50.0
600
150
92
VGS-600-15
15
14.7 ~ 15.8
40.0
600
150
92
VGS-600-24
24
23.5 ~ 25.2
25.0
600
200
94
VGS-600-27
27
26.4 ~ 28.4
22.3
600
200
94
VGS-600-36
36
35.3 ~ 37.8
16.7
600
300
94
VGS-600-48
48
47.0 ~ 50.4
12.6
600
300
94
Notes:
1. Ripple & noise are measured at 20 MHz BW with 47 µF aluminum electrolytic capacitor and 0.1 µF ceramic capacitor on the output.
2. Measured at 230 Vac
PART NUMBER KEY
VGS-600 - XX
Base Number
Output Voltage
cui.com
Additional Resources:
Product Page
|
3D Model
CUI Inc │ SERIES: VGS-600 │ DESCRIPTION: AC-DC POWER SUPPLY
date 09/09/2022 │ page 2 of 7
INPUT
parameter
conditions/description
min
max
units
voltage
ac input
dc input
80
110
277
390
Vac
Vdc
47
63
Hz
7.5
3.5
A
A
0.1
mA
frequency
current
at 115 Vac
at 230 Vac
inrush current
at 230 Vac, cold start
leakage current
at 240 Vac
no load power consumption
at 230 Vac, 25°C, on/off add +5V signal
power factor
at 115 Vac, full load
at 230 Vac, full load
typ
40
A
0.5
W
0.98
0.95
OUTPUT
parameter
conditions/description
capacitive load
12
24
36
48
total regulation
+5 VSB output, standby, full load
all other outputs, full load
line regulation
Vdc
Vdc
Vdc
Vdc
min
typ
& 15 Vdc output
& 27 Vdc output
output
output
max
units
6,000
4,000
2,400
1,600
μF
μF
μF
μF
±2
±1
%
%
+5 VSB output, standby, rated load
all other outputs, rated load
±0.5
±0.3
%
%
load regulation
+5 VSB output, standby, 0%~100% load
all other outputs, 0%~100% load
±2
±0.5
%
%
hold-up time
at 230 Vac
15
ms
PROTECTIONS
parameter
conditions/description
over voltage protection
12
15
24
27
36
48
over current protection
auto-recovery
short circuit protection
hiccup, continuous, auto-recovery in < 3 s after short removed
over temperature protection
output turns off and self recovers after temperature drops
Vdc
Vdc
Vdc
Vdc
Vdc
Vdc
output,
output,
output,
output,
output,
output,
min
typ
latching
latching
latching
latching
latching
latching
110
max
units
16
20
32
35
47
60
Vdc
Vdc
Vdc
Vdc
Vdc
Vdc
160
%
max
units
SAFETY & COMPLIANCE
parameter
conditions/description
min
isolation voltage
input to ground for 1 minute, 5 mA max
input to output for 1 minute, 5 mA max
output to ground for 1 minute, 5 mA max
insulation resistance
input to ground, 500 Vdc
input to output, 500 Vdc
output to ground, 500 Vdc
safety approvals
certified to
i i62368: IEC/EN/UL
designed to meet 61558: EN
designed to meet 60335: EN
safety class
Class I
conducted emissions
CISPR32/EN55032 CLASS B
radiated emissions
CISPR32/EN55032 CLASS B
harmonic flicker
IEC/EN61000-3-2 CLASS A and CLASS D
cui.com
typ
1,500
4,000
1,500
Vac
Vac
Vac
50
50
50
MΩ
MΩ
MΩ
Additional Resources:
Product Page
|
3D Model
CUI Inc │ SERIES: VGS-600 │ DESCRIPTION: AC-DC POWER SUPPLY
date 09/09/2022 │ page 3 of 7
SAFETY & COMPLIANCE
voltage flicker
IEC/EN61000-3-3
parameter
conditions/description
ESD
IEC/EN 61000-4-2 Contact ±8KV/Air ±15KV, perf. Criteria A
radiated immunity
IEC/EN 61000-4-3 10V/m, perf. Criteria A
EFT/burst
IEC/EN 61000-4-4 ±4KV, perf. Criteria A
surge
IEC/EN 61000-4-5 line to line ±2KV/line to ground ±4KV, perf. Criteria A
conducted immunity
IEC/EN61000-4-6 10 Vr.m.s, perf. Criteria A
voltage dips and interruptions
IEC/EN61000-4-11 0%, 70%, perf. Criteria B
MTBF
as per MIL-HDBK-217F at 25°C
RoHS
yes
min
typ
max
300,000
units
hours
ENVIRONMENTAL
parameter
conditions/description
min
operating temperature
storage temperature
max
units
-40
typ
70
°C
-40
85
°C
operating humidity
non-condensing
20
95
%
storage humidity
non-condensing
10
95
%
power derating
operating temperature
derating
50°C ~ 70°C
input voltage derating
80 Vac ~ 85 Vac
85 Vac ~ 100 Vac
cui.com
2.5
%/°C
2.0
1.33
%/Vac
Additional Resources:
Product Page
|
3D Model
CUI Inc │ SERIES: VGS-600 │ DESCRIPTION: AC-DC POWER SUPPLY
date 09/09/2022 │ page 4 of 7
MECHANICAL
parameter
conditions/description
dimensions
101.6 x 203.1 x 40.6
min
typ
max
units
mm
weight
1,000
cooling
forced air cooling
case material
metal (AL1100, SGCC)
g
MECHANICAL DRAWING
units: mm [inch]
adj: output adjustable resistor
input connector wire range: 22 ~ 14 awg
input connector tightening torque: M4, 1.2 N·m (max)
output connector (-V0/+V0) tightening torque: M5, 2.4 N·m (max)
tolerance: ±1.0 [±0.039]
PIN CONNECTIONS
PIN
Function
1
2
AC (L)
3
AC (N)
4
+Vo
5
-Vo
Figure
Position
Output connector J1
PIN
Function
PIN
Function
1
-S
2
+S
3
NC
4
NC
5
DC_OK-
6
DC_OK+
7
+5VSB
8
5VSB_RTN
9
RC+
10
RC-
11
+5VSB
12
+5VSB
13
5VSB_RTN
14
5VSB_RTN
Customer connector
1 - 8
MOLEX PN:
51110-1450
(without locking ramp)
or
5110-1451
(with locking ramp)
or equivalent
cui.com
Screw
spec.
L (max)
Torque
(max)
M3
4 mm
0.4 N·m
Note: At least one hole position, 1 ~ 8 , must be securely connected
to Protective Earth (PE)
Additional Resources:
Product Page
CUI Inc │ SERIES: VGS-600 │ DESCRIPTION: AC-DC POWER SUPPLY
|
3D Model
date 09/09/2022 │ page 5 of 7
TYPICAL APPLICATION
REMOTE ON/OFF
Figure 1
Table 1
R1
(Product inside)
2KΩ,
V2
(User side)
1
W
12
5V ~ 15V
1. When the product is working normally, apply voltage (5-15V) to RC+ and RC- to trigger the remote ON/OFF function,
and the output voltage will be off. Withdraw the voltage, the output voltage will be re-established.
2. 5V standby power supply is not controlled by remote ON/OFF function.
DC_OK
Figure 2
Table 2
R2
(Product inside)
V1
(User side)
1KΩ,
1
W
12
5V ~ 15V
1. When the output voltage of the product reaches 90% of the rated value, DC_OK+ will be connected to DC_OK-.
2. It is recommended that users apply a certain voltage between DC_OK+ and DC_OK- to detect the signal.
REMOTE SENSE COMPENSATION
Figure 3
1. The left side represents the internal schematic diagram of the product, the right side represents the customer system.
2. Twisted pair wires are needed for S+/S-.
cui.com
Additional Resources:
Product Page
CUI Inc │ SERIES: VGS-600 │ DESCRIPTION: AC-DC POWER SUPPLY
|
3D Model
date 09/09/2022 │ page 6 of 7
DERATING CURVE
EFFICIENCY CURVES
Notes:
3.
4.
5.
6.
The room temperature derating of 5°C/1000m is needed for operating altitude greater than 2000m.
In order to improve the efficiency at high input voltage, there will be audible noise generated, but it does not affect product performance and reliability.
The out case needs to be connected to PE ( ) of system when the terminal equipment in operating.
CAUTION: Double pole, neutral fusing. Disconnect mains before servicing.
ATTENTION: Double pôle/fusible sur le neutre. Débrancher lalimentation avant lentretien.
cui.com
Additional Resources:
Product Page
|
3D Model
CUI Inc │ SERIES: VGS-600 │ DESCRIPTION: AC-DC POWER SUPPLY
date 09/09/2022 │ page 7 of 7
REVISION HISTORY
rev.
1.0
description
date
initial release
09/09/2022
The revision history provided is for informational purposes only and is believed to be accurate.
Headquarters
20050 SW 112th Ave.
Tualatin, OR 97062
800.275.4899
Fax 503.612.2383
cui.com
techsupport@cui.com
CUI offers a two (2) year limited warranty. Complete warranty information is listed on our website.
CUI reserves the right to make changes to the product at any time without notice. Information provided by CUI is believed to be accurate and reliable. However, no responsibility is
assumed by CUI for its use, nor for any infringements of patents or other rights of third parties which may result from its use.
CUI products are not authorized or warranted for use as critical components in equipment that requires an extremely high level of reliability. A critical component is any component of a
life support device or system whose failure to perform can be reasonably expected to cause the failure of the life support device or system, or to affect its safety or effectiveness.