VGS-600-36 数据手册
Additional Resources: Product Page | 3D Model date 09/09/2022 page 1 of 7 SERIES: VGS-600 │ DESCRIPTION: INTERNAL AC-DC POWER SUPPLY FEATURES • • • • • • • • • • • • UL/EN 62368 certified active PFC temperature range -40°C to +70°C isolation up to 4000 Vac operating altitude up to 5000 m remote on/off short-circuit, over-current, over-voltage & over-temperature protection AC or DC input internal fan cooling PCB conformal coating 5 V, 1 A standby supply remote output voltage sensing MODEL output voltage output current output power ripple and noise1 efficiency2 (Vdc) range (Vdc) max (A) max (W) typ (mVp-p) typ (%) VGS-600-12 12 11.8 ~ 12.6 50.0 600 150 92 VGS-600-15 15 14.7 ~ 15.8 40.0 600 150 92 VGS-600-24 24 23.5 ~ 25.2 25.0 600 200 94 VGS-600-27 27 26.4 ~ 28.4 22.3 600 200 94 VGS-600-36 36 35.3 ~ 37.8 16.7 600 300 94 VGS-600-48 48 47.0 ~ 50.4 12.6 600 300 94 Notes: 1. Ripple & noise are measured at 20 MHz BW with 47 µF aluminum electrolytic capacitor and 0.1 µF ceramic capacitor on the output. 2. Measured at 230 Vac PART NUMBER KEY VGS-600 - XX Base Number Output Voltage cui.com Additional Resources: Product Page | 3D Model CUI Inc │ SERIES: VGS-600 │ DESCRIPTION: AC-DC POWER SUPPLY date 09/09/2022 │ page 2 of 7 INPUT parameter conditions/description min max units voltage ac input dc input 80 110 277 390 Vac Vdc 47 63 Hz 7.5 3.5 A A 0.1 mA frequency current at 115 Vac at 230 Vac inrush current at 230 Vac, cold start leakage current at 240 Vac no load power consumption at 230 Vac, 25°C, on/off add +5V signal power factor at 115 Vac, full load at 230 Vac, full load typ 40 A 0.5 W 0.98 0.95 OUTPUT parameter conditions/description capacitive load 12 24 36 48 total regulation +5 VSB output, standby, full load all other outputs, full load line regulation Vdc Vdc Vdc Vdc min typ & 15 Vdc output & 27 Vdc output output output max units 6,000 4,000 2,400 1,600 μF μF μF μF ±2 ±1 % % +5 VSB output, standby, rated load all other outputs, rated load ±0.5 ±0.3 % % load regulation +5 VSB output, standby, 0%~100% load all other outputs, 0%~100% load ±2 ±0.5 % % hold-up time at 230 Vac 15 ms PROTECTIONS parameter conditions/description over voltage protection 12 15 24 27 36 48 over current protection auto-recovery short circuit protection hiccup, continuous, auto-recovery in < 3 s after short removed over temperature protection output turns off and self recovers after temperature drops Vdc Vdc Vdc Vdc Vdc Vdc output, output, output, output, output, output, min typ latching latching latching latching latching latching 110 max units 16 20 32 35 47 60 Vdc Vdc Vdc Vdc Vdc Vdc 160 % max units SAFETY & COMPLIANCE parameter conditions/description min isolation voltage input to ground for 1 minute, 5 mA max input to output for 1 minute, 5 mA max output to ground for 1 minute, 5 mA max insulation resistance input to ground, 500 Vdc input to output, 500 Vdc output to ground, 500 Vdc safety approvals certified to i i62368: IEC/EN/UL designed to meet 61558: EN designed to meet 60335: EN safety class Class I conducted emissions CISPR32/EN55032  CLASS B radiated emissions CISPR32/EN55032  CLASS B harmonic flicker IEC/EN61000-3-2 CLASS A and CLASS D cui.com typ 1,500 4,000 1,500 Vac Vac Vac 50 50 50 MΩ MΩ MΩ Additional Resources: Product Page | 3D Model CUI Inc │ SERIES: VGS-600 │ DESCRIPTION: AC-DC POWER SUPPLY date 09/09/2022 │ page 3 of 7 SAFETY & COMPLIANCE voltage flicker IEC/EN61000-3-3 parameter conditions/description ESD IEC/EN 61000-4-2  Contact ±8KV/Air ±15KV, perf. Criteria A radiated immunity IEC/EN 61000-4-3  10V/m, perf. Criteria A EFT/burst IEC/EN 61000-4-4  ±4KV, perf. Criteria A surge IEC/EN 61000-4-5 line to line ±2KV/line to ground ±4KV, perf. Criteria A conducted immunity IEC/EN61000-4-6 10 Vr.m.s, perf. Criteria A voltage dips and interruptions IEC/EN61000-4-11 0%, 70%, perf. Criteria B MTBF as per MIL-HDBK-217F at 25°C RoHS yes min typ max 300,000 units hours ENVIRONMENTAL parameter conditions/description min operating temperature storage temperature max units -40 typ 70 °C -40 85 °C operating humidity non-condensing 20 95 % storage humidity non-condensing 10 95 % power derating operating temperature derating 50°C ~ 70°C input voltage derating 80 Vac ~ 85 Vac 85 Vac ~ 100 Vac cui.com 2.5 %/°C 2.0 1.33 %/Vac Additional Resources: Product Page | 3D Model CUI Inc │ SERIES: VGS-600 │ DESCRIPTION: AC-DC POWER SUPPLY date 09/09/2022 │ page 4 of 7 MECHANICAL parameter conditions/description dimensions 101.6 x 203.1 x 40.6 min typ max units mm weight 1,000 cooling forced air cooling case material metal (AL1100, SGCC) g MECHANICAL DRAWING units: mm [inch] adj: output adjustable resistor input connector wire range: 22 ~ 14 awg input connector tightening torque: M4, 1.2 N·m (max) output connector (-V0/+V0) tightening torque: M5, 2.4 N·m (max) tolerance: ±1.0 [±0.039] PIN CONNECTIONS PIN Function 1 2 AC (L) 3 AC (N) 4 +Vo 5 -Vo Figure Position Output connector J1 PIN Function PIN Function 1 -S 2 +S 3 NC 4 NC 5 DC_OK- 6 DC_OK+ 7 +5VSB 8 5VSB_RTN 9 RC+ 10 RC- 11 +5VSB 12 +5VSB 13 5VSB_RTN 14 5VSB_RTN Customer connector 1 - 8 MOLEX PN: 51110-1450 (without locking ramp) or 5110-1451 (with locking ramp) or equivalent cui.com Screw spec. L (max) Torque (max) M3 4 mm 0.4 N·m Note: At least one hole position, 1 ~ 8 , must be securely connected to Protective Earth (PE) Additional Resources: Product Page CUI Inc │ SERIES: VGS-600 │ DESCRIPTION: AC-DC POWER SUPPLY | 3D Model date 09/09/2022 │ page 5 of 7 TYPICAL APPLICATION REMOTE ON/OFF Figure 1 Table 1 R1 (Product inside) 2KΩ, V2 (User side) 1 W 12 5V ~ 15V 1. When the product is working normally, apply voltage (5-15V) to RC+ and RC- to trigger the remote ON/OFF function, and the output voltage will be off. Withdraw the voltage, the output voltage will be re-established. 2. 5V standby power supply is not controlled by remote ON/OFF function. DC_OK Figure 2 Table 2 R2 (Product inside) V1 (User side) 1KΩ, 1 W 12 5V ~ 15V 1. When the output voltage of the product reaches 90% of the rated value, DC_OK+ will be connected to DC_OK-. 2. It is recommended that users apply a certain voltage between DC_OK+ and DC_OK- to detect the signal. REMOTE SENSE COMPENSATION Figure 3 1. The left side represents the internal schematic diagram of the product, the right side represents the customer system. 2. Twisted pair wires are needed for S+/S-. cui.com Additional Resources: Product Page CUI Inc │ SERIES: VGS-600 │ DESCRIPTION: AC-DC POWER SUPPLY | 3D Model date 09/09/2022 │ page 6 of 7 DERATING CURVE EFFICIENCY CURVES Notes: 3. 4. 5. 6. The room temperature derating of 5°C/1000m is needed for operating altitude greater than 2000m. In order to improve the efficiency at high input voltage, there will be audible noise generated, but it does not affect product performance and reliability. The out case needs to be connected to PE ( ) of system when the terminal equipment in operating. CAUTION: Double pole, neutral fusing. Disconnect mains before servicing. ATTENTION: Double pôle/fusible sur le neutre. Débrancher lalimentation avant lentretien. cui.com Additional Resources: Product Page | 3D Model CUI Inc │ SERIES: VGS-600 │ DESCRIPTION: AC-DC POWER SUPPLY date 09/09/2022 │ page 7 of 7 REVISION HISTORY rev. 1.0 description date initial release 09/09/2022 The revision history provided is for informational purposes only and is believed to be accurate. Headquarters 20050 SW 112th Ave. Tualatin, OR 97062 800.275.4899 Fax 503.612.2383 cui.com techsupport@cui.com CUI offers a two (2) year limited warranty. Complete warranty information is listed on our website. CUI reserves the right to make changes to the product at any time without notice. Information provided by CUI is believed to be accurate and reliable. However, no responsibility is assumed by CUI for its use, nor for any infringements of patents or other rights of third parties which may result from its use. CUI products are not authorized or warranted for use as critical components in equipment that requires an extremely high level of reliability. A critical component is any component of a life support device or system whose failure to perform can be reasonably expected to cause the failure of the life support device or system, or to affect its safety or effectiveness.
VGS-600-36
物料型号: - 系列名称:VGS-600 - 型号示例:VGS-600-12, VGS-600-15, VGS-600-24, VGS-600-27, VGS-600-36, VGS-600-48

器件简介: - 这是一个内部AC-DC电源,具有以下特点: - UL/EN 62368认证 - 有源功率因数校正(active PFC) - 工作温度范围:-40°C至+70°C - 隔离电压高达4000Vac - 工作海拔高达5000米 - 远程开关功能 - 具有短路、过流、过压和过温保护 - 支持AC或DC输入 - 内部风扇冷却 - PCB涂层

引脚分配: - 输入端子:AC(L)、AC(N)、+Vo、-Vo - 输出端子:包括+5VSB、DC_OK+、DC_OK-、RC+、RC-等

参数特性: - 输入电压:AC 80Vac至277Vac,DC 110Vdc至390Vdc - 输出电压:12V至48V,具体取决于型号 - 输出功率:最高600W - 效率:最高94% - 纹波和噪声:在20MHz带宽下测量,输出端有47µF铝电解电容和0.1µF陶瓷电容

功能详解: - 远程开/关功能:通过RC+和RC-端子实现 - 输出电压感应:远程输出电压感应功能 - 保护功能:包括过压、过流、短路和过温保护

应用信息: - 典型应用包括远程开/关和远程感应补偿 - 提供了应用电路图和表格,说明如何实现这些功能

封装信息: - 尺寸:101.6x203.1x40.6毫米 - 重量:约1000克 - 冷却方式:强制空气冷却 - 外壳材料:金属(AL1100, SGCC)
VGS-600-36 价格&库存