SERIES: VHS1-SIP │ DESCRIPTION: DC-DC CONVERTER
FEATURES
•
•
•
•
•
•
•
•
1 W isolated output
industry standard 7 pin SIP package
single unregulated outputs
6,000 V isolation
short circuit protection
UL safety approvals
wide temperature (-40~105°C)
efficiency up to 82%
RoHS
MODEL
input
voltage
output
voltage
output
current
output
power
ripple
and noise1
efficiency
typ
(Vdc)
range
(Vdc)
(Vdc)
min
(mA)
max
(mA)
max
(W)
max
(mVp-p)
typ
(%)
VHS1-S5-S5-SIP
5
4.5~5.5
5
20
200
1
200
78
VHS1-S5-S9-SIP
5
4.5~5.5
9
12
111
1
200
79
VHS1-S5-S12-SIP
5
4.5~5.5
12
9
84
1
200
79
VHS1-S5-S15-SIP
5
4.5~5.5
15
7
67
1
200
79
VHS1-S12-S5-SIP
12
10.8~13.2
5
20
200
1
200
80
VHS1-S12-S9-SIP
12
10.8~13.2
9
12
111
1
200
82
VHS1-S12-S12-SIP
12
10.8~13.2
12
9
84
1
200
81
VHS1-S12-S15-SIP
12
10.8~13.2
15
7
67
1
200
82
Notes:
1. ripple and noise are measured at 20 MHz BW
PART NUMBER KEY
VHS1 - SXX - SXX -SIP
Base Number
Input Voltage
Output Voltage
cui.com
Packaging Style
Additional Resources:
Product Page
|
3D Model
|
PCB Footprint
CUI Inc │ SERIES: VHS1-SIP │ DESCRIPTION: DC-DC CONVERTER
date 07/09/2021 │ page 2 of 5
INPUT
parameter
conditions/description
min
typ
max
units
operating input voltage
5 V model
12 V model
4.5
10.8
5
12
5.5
13.2
Vdc
Vdc
parameter
conditions/description
min
typ
line regulation
for Vin change of 1%
load regulation
measured from 10%
load to full load
voltage accuracy
see derating curves
switching frequency
100% load, input
voltage range
OUTPUT
5 V model
9 V model
12 V model
15 V model
5 V input models
12 V input models
35
35
temperature coefficient
max
units
±1.2
%
12.8
8.3
6.8
6.3
15
15
15
15
%
%
%
%
40
50
65
65
kHz
kHz
±0.03
%/°C
PROTECTIONS
parameter
conditions/description
short circuit protection
continuous
min
typ
max
units
1
s
max
units
SAFETY AND COMPLIANCE
parameter
conditions/description
isolation voltage
for 1 minute at 1 mA max.
6,000
min
Vdc
isolation resistance
at 500 Vdc
1,000
MΩ
safety approvals
UL 60950-1
3,500,000
hours
MTBF
RoHS
typ
2011/65/EU
ENVIRONMENTAL
parameter
conditions/description
min
max
units
operating temperature
see derating curve
-40
105
°C
-55
125
°C
95
%
25
°C
300
°C
storage temperature
storage humidity
non-condensing
temperature rise
at full load
lead temperature
1.5 mm from case for 10 seconds
typ
15
cui.com
Additional Resources:
Product Page
|
3D Model
|
PCB Footprint
CUI Inc │ SERIES: VHS1-SIP │ DESCRIPTION: DC-DC CONVERTER
date 07/09/2021 │ page 3 of 5
DERATING CURVES
MECHANICAL
parameter
conditions/description
dimensions
19.50 x 9.80 x 12.50 (0.768 x 0.386 x 0.492 inch)
min
case material
plastic (UL94-V0)
typ
max
mm
weight
4.2
g
MECHANICAL DRAWING
units: mm [inches]
tolerance: ±0.25 [±0.010]
pin section tolerance: ±0.10 mm [±0.004]
19.50 [0.768]
9.80 [0.386]
(Side View)
12.50 [0.492]
4.10 [0.161]
0.50 [0.020]
7.62 [0.300]
2.54 [0.100]
(Bottom View)
1
2
5 6
7
0.30 [0.012]
3.20 [0.126]
2.00 [0.079]
0.50 [0.020]
cui.com
units
1
2
5
7
PIN CONNECTIONS
PIN
FUNCTION
1
+Vin
2
GND
5
0V
6
No PIN
7
+Vo
Additional Resources:
Product Page
|
3D Model
|
PCB Footprint
CUI Inc │ SERIES: VHS1-SIP │ DESCRIPTION: DC-DC CONVERTER
date 07/09/2021 │ page 4 of 5
APPLICATION NOTES
1. Requirement on Output Load
In order to ensure the product operates efficiently and reliably, make sure the specified range of input voltage is not exceeded and the
minimum output load is not less than 10% load. If the actual load is less than the specified minimum load, the output ripple may
increase sharply while its efficiency and reliability will reduce greatly. If the actual output power is very small, please add an
appropriate resistor as extra loading.
2. Overload Protection
Under normal operating conditions, the output circuit of these products has no protection against over-current and short-circuits. The
simplest method is to connect a self-recovery fuse in series at the input end or add a circuit breaker to the circuit.
3. Filtering
In some circuits which are sensitive to noise and ripple, a filtering capacitor may be added to the DC/DC output end and input end to
reduce the noise and ripple. However, the capacitance of the output filter capacitor must be proper. If the capacitance is too big, a
startup problem might arise. For every channel of output, provided the safe and reliable operation is ensured, the greatest
capacitance of its filter capacitor sees the external capacitor table. To get an extremely low ripple, an “LC” filtering network may be
connected to the input and output ends of the DC/DC converter, which may produce a more significant filtering effect. It should also
be noted that the inductance and the frequency of the “LC” filtering network should be staggered with the DC/DC frequency to avoid
mutual interference (Figure 1).
Figure 1
4. Output Voltage Regulation and Over-voltage Protection Circuit
The simplest device for output voltage regulation, over-voltage and over-current protection is a linear voltage regulator with overheat
protection that is connected to the input or output end in series (Figure 2).
Figure 2
5. External Capacitor Table
It is not recommended to connect any external capacitor in the application field with less than 0.5 W output.
Table 1
Note:
Vin
(Vdc)
Cout
(µF)
Vout
(Vdc)
Cout
(µF)
5
4.7
5
10
12
2.2
9
4.7
--
--
12
2.2
--
--
15
1
All specifications measured at 25°C, humidity