date page
07/27/2011 1 of 5
SERIES: VMS-160 │ DESCRIPTION: AC-DC POWER SUPPLY
FEATURES
• • • • • • • • • • • Up to 160 W continuous power Industry standard 2” x 4” footprint 18 W/in3 power density Universal input (85-264 Vac / 125-373 Vdc) Single output from 5 to 48 V Active power correction (98%) 12 V auxiliary fan output No minimum load required Over load, over voltage, and short circuit protections Full medical and ITE safety approvals Efficiency up to 90%
RoHS
MODEL
VMS-160-5 VMS-160-12 VMS-160-15 VMS-160-24 VMS-160-48
Notes: 1. 2. 3. 4.
output voltage
(Vdc)
output current
max (A)
output power
max (W)
ripple and noise4
max (mVp-p)
efficiency
typ (%)
5 12 15 24 48
20 13.3 8 6.66 3.33
1002 160
1
50 120 50 240 480
90 90 90 90 90
1603 1601 1601
Total continuous output power will not exceed 160 W forced air (400 LFM), 100 W without fan Total continuous output power will not exceed 100 W forced air (400 LFM), 70 W without fan Total continuous output power will not exceed 120 W forced air (400 LFM), 90 W without fan Measured at 20 MHz, twisted pair with 0.47 μF ceramic and 22 μF tantalum parallel capacitors
PART NUMBER KEY
VMS-160 - XX
Base Number Output Voltage
cui.com
CUI Inc │ SERIES: VMS-160 │ DESCRIPTION: AC-DC POWER SUPPLY
date 07/27/2011 │ page 2 of 5
INPUT
parameter voltage frequency current inrush current power factor at 100 Vac, cold start at 200 Vac, cold start at 230 Vac, full load, cold start measured at full load and 115 Vac/60 Hz and 0.85 230 Vac/50 Hz input source input will be less than 0.25Ω, compliant to EN61000-3-2 for harmonic currents 0.98 conditions/description min 90 125 47 typ max 264 373 63 2.5 1.25 units Vac Vdc Hz A A
OUTPUT
parameter line regulation load regulation temperature coefficient transient response start-up time rise time hold-up time adjustability fan drive 12 Vdc / 500 mA for external fan 0.2 16 ±5 conditions/description low line to high line all other outputs 12 V aux. output min typ ±1 ±1 ±20 0.25 25% Imax to Imax , 0.1 A/μs slew rate, ±5% max. deviation, 1 ms recovery 1 20 s ms ms % max units % % % mV/°C
PROTECTION
parameter over voltage protection over current protection short circuit protection automatically recovers auto recovery with no damage from a short on any output conditions/description min typ max 130 150 units % %
SAFETY & COMPLIANCE
parameter isolation voltage safety approvals EMI/EMC conditions/description primary to secondary (for 1 second): primary to earth ground (for 1 second): min 5,656 5,656 typ max units Vdc Vdc
UL 60950-1/60601-1, NEMKO EN60950-1/EN60601-1, CE EN55022:1998 (CISPR 22 class A conducted), EN61000-3-2: 2000, EN61000-3-3: A1:2001, EN55024 (IEC61000-4-2: 1995, IEC61000-4-3: 1995, IEC61000-4-4: 1995, IEC61000-4-5: 1995, IEC61000-4-6: 1996, IEC61000-4-11: 1994) measured per IEC 60950-1, paragraph 5.1, test voltage of 120 Vac/60 Hz yes with 400 LFM forced air, MIL-HDBK-217E-1, 75% of rated full load, 25°C ambient 200,000 hrs 0.275 mA
leakage current RoHS compliant MTBF
cui.com
CUI Inc │ SERIES: VMS-160 │ DESCRIPTION: AC-DC POWER SUPPLY
date 07/27/2011 │ page 3 of 5
ENVIRONMENTAL
parameter operating temperature storage temperature operating humidity storage humidity shock vibration conditions/description see derating curve see derating curve non-condensing non-condensing min -20 -40 8 10 140 1 2 typ max 50 80 90 95 units °C °C % % G G Grms Grms
operating (11 ms, half sine, for a total of 6 shock inputs) non-operating (2 ms, half sine, for a total of 6 shock inputs) operating (10 ~ 300 Hz, 1 hour per axis, 3 hours total) non-operating (10 ~ 500 Hz, 1 hour per axis, 3 hours total)
DERATING CURVES
output power vs. ambient temperature
100
2 1 1 2 Convection Forced air (400 LFM)
Load (%)
80 60 40 20
-20
0
10
20
30
40
50
60
70
Ambient Temperature (°C)
100
2 1 1 2 Convection Forced air (400 LFM)
Load (%)
80 60 40 20
-20
0
10
20
30
40
50
60
70
Ambient Temperature (°C)
100
2 1 1 2 Convection Forced air (400 LFM)
Load (%)
80 60 40 20
-20
0
10
20
30
40
50
60
70
Ambient Temperature (°C)
cui.com
CUI Inc │ SERIES: VMS-160 │ DESCRIPTION: AC-DC POWER SUPPLY
date 07/27/2011 │ page 4 of 5
MECHANICAL DRAWING
CN3
1 2 3 4 101.6 4.000 95.3 3.752 MAX DIA OF MOUNTING HARDWARE Ø6.35 (Ø0.250) TYP 4 PLCS 1 4 8 50.8 2.000 1 2 3 4 5 6 7 8 GND GND 12V (FAN) 12V (FAN) MOLEX (22-23-2021) 4 PIN 0.10 SPACING Ø4.04 (Ø0.159) MOUNTING HOLE TYP 4 PLCS
CN2
dc dc dc dc return return return return V1 V1 V1 V1
CN1
1 2 ac neutral ac line
1 2 1
MOLEX (26-60-4030) 3 PIN, CTR PIN REMOVED 0.156 SPACING
44.5 1.752
QUICK DISCONNECT TAB 6.35 (0.250) X 0.81 (0.032) MOLEX (19705-4301)
MOLEX (26-60-4080) 8 PIN 0.156 SPACING
21.59 0.850 27.5 1.082
4.4 0.173 MAX SMT COMPONENT HEIGHT
cui.com
CUI Inc │ SERIES: VMS-160 │ DESCRIPTION: AC-DC POWER SUPPLY
date 07/27/2011 │ page 5 of 5
REVISION HISTORY
rev. 1.0 1.01 description initial release applied new spec template date 05/5/2009 06/16/2011
The revision history provided is for informational purposes only and is believed to be accurate.
Headquarters 20050 SW 112th Ave. Tualatin, OR 97062 800.275.4899
CUI offers a two (2) year limited warranty. Complete warranty information is listed on our website.
Fax 503.612.2383 cui.com techsupport@cui.com
CUI reserves the right to make changes to the product at any time without notice. Information provided by CUI is believed to be accurate and reliable. However, no responsibility is assumed by CUI for its use, nor for any infringements of patents or other rights of third parties which may result from its use. CUI products are not authorized or warranted for use as critical components in equipment that requires an extremely high level of reliability. A critical component is any component of a life support device or system whose failure to perform can be reasonably expected to cause the failure of the life support device or system, or to affect its safety or effectiveness.
很抱歉,暂时无法提供与“VMS-160-15”相匹配的价格&库存,您可以联系我们找货