Additional Resources:
Product Page
|
3D Model
date
11/08/2021
page
1 of 7
SERIES: VOF-130 │ DESCRIPTION: AC-DC POWER SUPPLY
FEATURES
•
•
•
•
•
•
•
80 ~ 264 Vac input voltage range
2” x 3” open frame chassis
100 W power output with natural convection
130 W power output with forced air cooling
active PFC
IEC 62368-1 approved
IEC Class I & Class II safety approved
MODEL
output
voltage
output
current1
output
power2
ripple
and noise3
efficiency4
(Vdc)
max
(A)
max
(W)
max
(mVp-p)
typ
(%)
VOF-130-12
12
10.8
130
120
93
VOF-130-24
24
5.4
130
240
93
VOF-130-36
36
3.6
130
360
94
VOF-130-48
48
2.7
130
480
94
Notes:
1.
2.
3.
4.
Maximum output power of 130 W with 10 CFM forced air cooling, and 100 W with natural convection. See derating curves.
With forced air (10 CFM).
At full load, nominal input, 20 MHz bandwidth oscilloscope with 10 µF electrolytic and 0.1 µF ceramic capacitors.
At 230 Vac, 25°C, 75% load.
PART NUMBER KEY
VOF-130 - XX - XXX
Base Number
Output Voltage
cui.com
Chassis:
“blank” = open-frame
BP = base plate
CNF = covered
Additional Resources:
Product Page
|
3D Model
CUI Inc │ SERIES: VOF-130 │ DESCRIPTION: AC-DC POWER SUPPLY
date 11/08/2021 │ page 2 of 7
INPUT
parameter
conditions/description
min
voltage
typ
80
frequency
max
units
264
Vac
60
Hz
current
at 100 Vac, full load
47
1.8
A
inrush current
at 240 Vac, cold start
100
A
0.1
mA
leakage current
OUTPUT
parameter
conditions/description
output capacitance
12
24
36
48
initial set point accuracy
at full load
line regulation
100 ~ 240 Vac, full load
load regulation
10 ~ 100% load
hold-up time
at 115 Vac, 25°C
Vdc
Vdc
Vdc
Vdc
output
output
output
output
min
typ
model
model
model
model
max
units
8,400
4,200
2,720
2,040
µF
µF
µF
µF
±2
%
±0.5
%
±1
switching frequency
%
20
ms
105
kHz
PROTECTIONS
parameter
conditions/description
over voltage protection
auto recovery
12 Vdc output
24 Vdc output
36 Vdc output
48 Vdc output
over current protection
auto recovery
short circuit protection
auto recovery
min
model
model
model
model
typ
max
13.5
30
42
54
units
Vdc
Vdc
Vdc
Vdc
115
130
145
%
min
typ
max
units
SAFETY & COMPLIANCE
parameter
conditions/description
isolation voltage
input to output, for 1 minute
input to ground, for 1 minute
output to ground, for 1 minute
safety approvals
certified to 62368: IEC/EN/UL
safety class
class I, class II
conducted emissions
EN 55032, 47 CFR FCC Part 15 (Class I & Class II meets Class B)
radiated emissions
EN 55032, 47 CFR FCC Part 15 (Class I Meet Class B; Class II Meet Class A)
harmonic current
EN 61000-3-2:2014
voltage fluctuations and flicker
3,000
1,500
500
Vac
Vac
Vac
EN 61000-3-3:2013
ESD
IEC 61000-4-2:2008 Air Discharge: ±8kV, Contact Discharge: ±4kV, perf. Criteria A
radiated immunity
IEC 61000-4-3:2010, perf. Criteria A
EFT/burst
IEC 61000-4-4:2012, ±1kV, ±2kV, perf. Criteria A
surge
IEC 61000-4-5:2014, L-N: ±0.5kV, ±1kV, L-E(Ground): ±0.5kV, ±1kV, ±2kV, perf. Criteria A
conducted immunity
IEC 61000-4-6:2013
voltage dips and interruptions
IEC 61000-4-11:2004, Dip: 30% Reduction, Dip >95% Reduction, perf. Criteria A
IEC 61000-4-11:2004, >95% Reduction, perf. Criteria B
MTBF
as per MIL-HDBK-217F at 25°C
RoHS
yes
400,000
cui.com
hours
Additional Resources:
Product Page
|
3D Model
CUI Inc │ SERIES: VOF-130 │ DESCRIPTION: AC-DC POWER SUPPLY
date 11/08/2021 │ page 3 of 7
ENVIRONMENTAL
parameter
conditions/description
min
operating temperature
see derating curve
storage temperature
operating humidity
non-condensing
DERATING CURVES
EFFICIENCY CURVES
cui.com
typ
max
units
-30
70
°C
-40
85
°C
93
%
Additional Resources:
Product Page
|
3D Model
CUI Inc │ SERIES: VOF-130 │ DESCRIPTION: AC-DC POWER SUPPLY
date 11/08/2021 │ page 4 of 7
MECHANICAL
parameter
conditions/description
dimensions
open frame models: 3.000 x 2.000 x 1.201 [76.2 x 50.8 x 30.5 mm]
base plate models: 3.598 x 2.000 x 1.299 [91.4 x 50.8 x 33.0 mm]
covered models: 3.598 × 2.520 × 1.358 [91.4 x 64.0 x 34.5 mm]
min
weight
open frame models
base plate models
covered models
135
170
218
g
g
g
cooling
natural convection (no integrated fan), see derating curve
10 CFM
100
130
W
W
MECHANICAL DRAWING
Open-frame
units: inch [mm]
general tolerance: ±0.02 [±0.5]
PIN-OUT
PIN
Function
1
AC (L)
2
AC (N)
3
-Vo
4
-Vo
5
+Vo
6
+Vo
cui.com
typ
max
units
inches
inches
inches
Additional Resources:
Product Page
CUI Inc │ SERIES: VOF-130 │ DESCRIPTION: AC-DC POWER SUPPLY
Base plate
units: inch [mm]
general tolerance: ±0.02 [±0.5]
PIN-OUT
Function
1
AC (L)
2
AC (N)
3
-Vo
4
-Vo
5
+Vo
6
+Vo
3D Model
date 11/08/2021 │ page 5 of 7
MECHANICAL DRAWING (CONTINUED)
PIN
|
cui.com
Additional Resources:
Product Page
CUI Inc │ SERIES: VOF-130 │ DESCRIPTION: AC-DC POWER SUPPLY
Covered
units: inch [mm]
general tolerance: ±0.02 [±0.5]
PIN-OUT
Function
1
AC (L)
2
AC (N)
3
-Vo
4
-Vo
5
+Vo
6
+Vo
3D Model
date 11/08/2021 │ page 6 of 7
MECHANICAL DRAWING (CONTINUED)
PIN
|
cui.com
Additional Resources:
Product Page
|
3D Model
CUI Inc │ SERIES: VOF-130 │ DESCRIPTION: AC-DC POWER SUPPLY
date 11/08/2021 │ page 7 of 7
REVISION HISTORY
rev.
1.0
description
date
initial release
11/08/2021
The revision history provided is for informational purposes only and is believed to be accurate.
Headquarters
20050 SW 112th Ave.
Tualatin, OR 97062
800.275.4899
Fax 503.612.2383
cui.com
techsupport@cui.com
CUI offers a two (2) year limited warranty. Complete warranty information is listed on our website.
CUI reserves the right to make changes to the product at any time without notice. Information provided by CUI is believed to be accurate and reliable. However, no responsibility is
assumed by CUI for its use, nor for any infringements of patents or other rights of third parties which may result from its use.
CUI products are not authorized or warranted for use as critical components in equipment that requires an extremely high level of reliability. A critical component is any component of a
life support device or system whose failure to perform can be reasonably expected to cause the failure of the life support device or system, or to affect its safety or effectiveness.
很抱歉,暂时无法提供与“VOF-130-24”相匹配的价格&库存,您可以联系我们找货
免费人工找货