VOF-25-9

VOF-25-9

  • 厂商:

    CUI

  • 封装:

    -

  • 描述:

    AC/DC CONVERTER 9V 25W

  • 详情介绍
  • 数据手册
  • 价格&库存
VOF-25-9 数据手册
1/3 VOF-25 Switching Power Supply Rev. 07-2007 Features • • • • • • • • RoHS Compliant Universal input 85~264 Vac Output over-current protected Output over-voltage protected Industry standard foot-print Efficiency up to 82% Safety approved to TUV, CE; UL/cUL Conducted EMI meets EN55022 class B and FCC class B Model VOF-25-3.3 VOF-25-5 VOF-25-7.5 VOF-25-9 VOF-25-12 VOF-25-15 VOF-25-24 Notes: Voltage (V) 3.3 5 7.5 9 12 15 24 C urrent (A) 4.4 4.4 3.0 2.7 2.0 1.6 1.0 Total 1 ,2 Regulation ±5% ±5% ±5% ±5% ±5% ±5% ±5% Ripple & Noise 3 (mVp-p max) 50 50 75 90 120 150 240 Efficiency (%) 70 73 73 77 80 80 82 1. Measured from High Line to Low Line at Full load. 2. Measured from Full load to 10% load at 110 VAC. 3. Ripple & Noise measured at 20 MHz BW, with a 0.1 µF ceramic cap and a 10 µF electrolytic cap on the output and two earth ground pads are connected to input earth ground. Derating Curves 1. Output Power vs. Ambient temperature a. 3.3 V and 5 V models b. All other models (%) (%) (18 CFM) 2. Output Power vs. Input Voltage All Models (%) Input Voltage (VAC) V-INFINITY LLC, 9615 SW Allen Blvd., Suite 103, Beaverton, OR 97005 1-866-372-1258 www.v-infinity.com (%) 2/3 VOF-25 Switching Power Supply Rev. 07-2007 Input Parameter Input Frequency Input Voltage Input Current Inrush Current Input fuse Conditions/Description Output power derated from 85-90 VAC AC Input of 110 VAC AC Input of 210 VAC Measured at 110 VAC at full load, cold start Measured at 220 VAC at full load, cold start Built-in, non-user serviceable. Min 47 85 700 350 20 40 Nom Max 63 264 Units Hz VAC mA mA A A Output Parameter Efficiency Hold up time Adjustability Temp. Coefficient Conditions/Description Min Nom See table above. Typical values measured at 115 VAC, full load. At 115 VAC, full load 16 Adjustable with built-in trim pot. -5 -0.05 Max Units mS % %/ºC +5 +0.05 Protection Circuit Parameter Overload Output Over-voltage Short Circuit Conditions/Description Current limiting starts at 105% of the rated output current and recovers automatically. Output voltage is limited to 115% by TVS clamping. Protected. Long term short circuit may reduce reliability. General and Safety Parameter Operating temp. Storage temp. Operating humid. Storage humid. Operating altitude Storage altitude EMI Safety RoHS Leakage Current Isolation Voltage (HI-POT) Conducted emissions comply with FCC class B, EN55022 class B Approved to TUV EN60950, CE, CB; UL/cUL 60950-1 2002/95/EC Per EN60950, 264 VAC Applied for 1 minute. Primary to secondary: Primary to transformer core: Primary to earth ground: Measured at 500 VDC, at room temp. MIL-HDBK-217F Standard Warranty Length 1.5 3000 1500 1500 50 250K 2 mA VAC VAC VAC MΩ hours years Conditions/Description See derating curves. Non-condensing Non-condensing Min 0 -20 20% 20% Nom Max 50 85 90% 95% 3,000 10,000 9,000 30,000 Units ºC ºC RH RH m ft m ft Insulation Resistance MTBF ( @ 25ºC) Warranty V-INFINITY LLC, 9615 SW Allen Blvd., Suite 103, Beaverton, OR 97005 1-866-372-1258 www.v-infinity.com 3/3 VOF-25 Switching Power Supply Rev. 07-2007 Mechanical P arameter Dimensions Weight Cooling method Conditions/Description 3.5”(88.9mm) x 2”(51mm) x 0.8”(20.32mm) 0.09 free air convection (see derating curve on p. 1) kg Min Nom Max Units Mating Connectors Parameter AC Input (CN1) DC Output (CN2) Conditions/Description Mates with Molex housing 09-50-3031 with Molex 2878 series crimp contact. Mates with Molex housing 09-50-3041 with Molex 2878 series crimp contact. Outline Drawing 90.0 3.54 81.9±0.1 3.22 51.0 2.01 3 2 1 CN2 42.8±0.1 1.68 4 3 CN2 2 1 CN1(0411-3P) 1 N 2 no pin 3 L CN2(0411-4P) VADJ 3.5 (4 PLCS) MOUNTING HOLE 1 -V 2 -V 3 +V 4 +V *Tolerance: ±1 *Dimensions in mm 20.32 0.80 3.0 MAX (LEAD) *V-Infinity reserves the right to make changes to its products or to discontinue any product or service without notice, and to advise customers to verify the most up-to-date product information before placing orders. V-Infinity assumes no liability or responsibility for customer’s applications using V-Infinity products other than repair or replacing (at V-I’s option) V-Infinity products not meeting V-I’s published specifications. Nothing will be covered outside of standard product warranty. V-INFINITY LLC, 9615 SW Allen Blvd., Suite 103, Beaverton, OR 97005 1-866-372-1258 www.v-infinity.com
VOF-25-9
1. 物料型号: - 型号为VOF-25系列,具体型号包括VOF-25-3.3、VOF-25-5、VOF-25-7.5、VOF-25-9、VOF-25-12、VOF-25-15和VOF-25-24。

2. 器件简介: - VOF-25系列是符合RoHS标准的开关电源模块,具有85~264Vac的通用输入电压范围,输出过流和过压保护,效率高达82%,并通过了TUV、CE、UL/cUL等安全认证。

3. 引脚分配: - 输入端(CN1):1号脚为N(中性线),2号脚为空脚,3号脚为L(火线)。 - 输出端(CN2):1号脚和2号脚为-V(负电压),3号脚和4号脚为+V(正电压)。

4. 参数特性: - 输入频率:47Hz至63Hz。 - 输入电压:85至264Vac。 - 输入电流:在110Vac时为700mA,在210Vac时为350mA。 - 效率:根据不同型号,效率从70%至82%不等。 - 保持时间:16ms。 - 调整性:通过内置微调电位器可调,范围为-5%至+5%。

5. 功能详解: - 过载保护:电流限制从额定输出电流的105%开始,并可自动恢复。 - 输出过电压保护:通过TVS钳位限制输出电压至115%。 - 短路保护:具有短路保护,但长期短路可能会降低可靠性。

6. 应用信息: - 该模块适用于需要高效率和高可靠性的电源应用场合,具体应用需参考其电气参数和安全认证。

7. 封装信息: - 尺寸:3.5英寸(88.9mm)x 2英寸(51mm)x 0.8英寸(20.32mm)。 - 重量:0.09kg。 - 冷却方式:自由空气对流。
VOF-25-9 价格&库存

很抱歉,暂时无法提供与“VOF-25-9”相匹配的价格&库存,您可以联系我们找货

免费人工找货