Additional Resources:
Product Page
|
3D Model
date
04/06/2022
page
1 of 10
SERIES: VOF-450C │ DESCRIPTION: AC-DC POWER SUPPLY
FEATURES
•
•
•
•
•
•
•
•
90~264 Vac and 127~370 Vdc input voltage range
3” x 5” open-frame footprint
250 W under natural convection, 450 W with airflow
-40 ~ 70 °C temperature range
active PFC
5 Vsby, 12 Vfan, power good, remote sense
certified to 62368 safety standard
designed to meet 60335 & 61558 safety requirements
MODEL
output
voltage
output
current
output
power2
ripple
and noise3
efficiency4
(Vdc)
range¹
(Vdc)
max
(A)
max
(W)
max
(mVp-p)
typ
(%)
VOF-450C-12
12
11.4~12.6
33.3
400
200
91.0
VOF-450C-15
15
14.25~15.75
26.70
400
200
92.0
VOF-450C-24
24
22.8~25.2
18.75
450
200
93.0
VOF-450C-27
27
25.65~28.35
16.70
450
200
93.5
VOF-450C-36
36
34.2~37.8
12.50
450
200
93.0
VOF-450C-48
48
45.6~50.4
9.40
450
200
94.0
Notes:
1.
2.
3.
4.
When adjusting the output voltage care should be taken never to exceed the stated output power or output current of the unit.
With 25 CFM of forced air cooling.
At full load, nominal input, 20 MHz bandwidth oscilloscope, tip & barrel method, output terminated with 47 uF electrolytic and 0.1 uF ceramic capacitors.
At 230 Vac.
PART NUMBER KEY
VOF-450C - XX - XXX
Base Number
Output Voltage
cui.com
Chassis:
“blank” = open-frame
CNF = covered
CFS = enclosed with rear fan
Additional Resources:
Product Page
|
3D Model
CUI Inc │ SERIES: VOF-450C │ DESCRIPTION: AC-DC POWER SUPPLY
date 04/06/2022 │ page 2 of 10
INPUT
parameter
conditions/description
min
max
units
voltage
ac input
dc input
90
127
264
370
Vac
Vdc
47
63
Hz
5.2
2.6
A
A
frequency
current
at 90/115 Vac
at 230 Vac
inrush current
at 115 Vac, cold start
at 230 Vac, cold start
leakage current
at 264 Vac
contact leakage current
earth leakage current
power factor correction
at 115 Vac, full load
at 230 Vac, full load
no load power consumption
at 230 Vac, PS-ON signal held low (output disabled)
PS_ON input signal
typ
40
80
A
A
0.1
0.5
mA
mA
0.98
0.95
0.5
W
power ON
PS_ON high
2
5
V
power OFF
PS_ON low
0
0.5
V
max
units
6,000
4,000
3,000
2,000
μF
μF
μF
μF
OUTPUT
parameter
conditions/description
output capacitance
12, 15, 24 Vdc output models
27 Vdc output model
36 Vdc output model
48 Vdc output model
initial set point accuracy
full load
12,15, 24 Vdc output models
all other output models
line regulation
rated load
load regulation
0 ~ 100% load
hold-up time
at 115 Vac, 25°C, full load
at 230 Vac, 25°C, full load
min
±0.5
%
±1
%
ms
ms
±0.03
%/°C
6
VSTBY
Note:
%
%
output power of 12 Vdc/0.5A
5
5
PG signal
±2
±1
12
16
temperature coefficient
fan power
typ
power ON
The PG signal goes high
with 10ms~500ms
delay after power set up.
power OFF/power FAIL
W
V
10
500
ms
The TTL signal goes low
at least 1ms before
output below 90% at
rated value.
1
-
ms
HIGH level
high
2
6
V
LOW level
low
0
6
V
5. The load capacity is 0.6A without fan; the load capacity is 1A with fan 25CFM, tolerance2%, ripple: 120mVp-p(max.)
cui.com
Additional Resources:
Product Page
|
3D Model
CUI Inc │ SERIES: VOF-450C │ DESCRIPTION: AC-DC POWER SUPPLY
date 04/06/2022 │ page 3 of 10
PROTECTIONS
parameter
conditions/description
over voltage protection
output shutdown, latching
12 Vdc output model
15 Vdc output model
24 Vdc output model
27 Vdc output model
36 Vdc output model
48 Vdc output model
min
over current protection
auto recovery, hiccup
short circuit protection
continuous, auto recovery, hiccup, recovery time