Additional Resources:
Product Page
|
3D Model
date
05/13/2021
page
1 of 5
SERIES: VOF-50B │ DESCRIPTION: AC-DC POWER SUPPLY
FEATURES
•
•
•
•
•
safety Class II design
industry standard 2” x 4” footprint
no-load power consumption < 0.3 W
EN 55032 Class B radiated emissions
5k meters high altitude operation
MODEL
output
voltage
output
current
output
power
ripple
and noise1
efficiency2
(Vdc)
max
(A)
max
(W)
max
(mVp-p)
typ
(%)
VOF-50B-12
12
4.2
50.4
120
87
VOF-50B-15
15
3.4
51.0
150
88
VOF-50B-24
24
2.1
50.4
240
89
Notes:
1. Measured at output within 20 MHz BW, at rated line voltage and output load, with a 10 µF tantalum and a 0.1 µF ceramic capacitor across the output.
2. At 230 Vac.
PART NUMBER KEY
VOF-50B - XX
Base Number
Output Voltage
cui.com
Additional Resources:
Product Page
|
3D Model
CUI Inc │ SERIES: VOF-50B │ DESCRIPTION: AC-DC POWER SUPPLY
date 05/13/2021 │ page 2 of 5
INPUT
parameter
conditions/description
min
voltage
typ
90
frequency
47
max
units
264
Vac
63
Hz
current
at 115 Vac
at 230 Vac
1.7
0.8
A
A
inrush current
at 230 Vac, cold start, 25 °C
90
A
leakage current
at 264 Vac, 63 Hz
0.25
mA
no load power consumption
at 110 Vac
at 230 Vac
0.19
0.3
W
W
max
units
OUTPUT
parameter
conditions/description
min
initial set point accuracy
typ
±3
line regulation
at full load
load regulation
at 10% to full load
±1
adjustability
built in trim pot
±5
start-up time
at 100 Vac, full load
rise time
at 100 Vac, full load
hold-up time
at 115 Vac, full load
10
switching frequency
at full load
62
%
±0.5
%
%
%
1
50
s
ms
ms
temperature coefficient
87
kHz
±0.04
%/°C
max
units
130
%
max
units
PROTECTIONS
parameter
conditions/description
min
over voltage protection
latch off
110
over current protection
auto recovery
short circuit protection
auto recovery
over temperature protection
auto recovery
typ
SAFETY & COMPLIANCE
parameter
conditions/description
isolation voltage
input to output
safety approvals
UL 62368-1, EN 62368-1, IEC 62368-1
safety class
Class II
conducted emissions
EN 55032 Class B, FCC Class B
radiated emissions
EN 55032 Class B, FCC Class B
input current harmonics
EN 61000-3-2 Class A
voltage fluctuation and flicker
EN 61000-3-3
ESD immunity
EN 61000-4-2, air: ±8 kV; contact: ±4 kV contact
radiated field immunity
EN 61000-4-3, 3 V/m
electrical fast transient
immunity
EN 61000-4-4, ±2 kV
Notes:
min
typ
3,000
Vac
3. The power supply is considered a component which will be installed into final equipment. The final equipment still must be tested to meet the necessary EMC directives.
cui.com
Additional Resources:
Product Page
|
3D Model
CUI Inc │ SERIES: VOF-50B │ DESCRIPTION: AC-DC POWER SUPPLY
date 05/13/2021 │ page 3 of 5
SAFETY & COMPLIANCE (CONTINUED)
parameter
conditions/description
surge immunity
EN 61000-4-5, ±2 kV diff, ±4 kV com
conducted immunity
EN 61000-4-6, 3 Vrms
magnetic field immunity
EN 61000-4-8, 50 Hz, 1 A/m (rms), Class A
voltage dips, interruptions
EN 61000-4-11:
voltage dips 30% reduction for 500 ms, Class A
voltage dips >95% reduction for 10 ms, Class A
voltage dips >95% reduction for 5000 ms, Class B
MTBF
as per MIL-HDBK-217F, 25°C, full load
RoHS
yes
Notes:
min
typ
max
350,000
units
hours
4. The power supply is considered a component which will be installed into final equipment. The final equipment still must be tested to meet the necessary EMC directives.
ENVIRONMENTAL
parameter
conditions/description
min
operating temperature
see derating curves
storage temperature
operating humidity
non-condensing
max
units
-20
70
°C
-40
85
°C
95
%
5,000
m
5
altitude
DERATING CURVES
EFFICIENCY CURVES
cui.com
typ
Additional Resources:
Product Page
|
3D Model
CUI Inc │ SERIES: VOF-50B │ DESCRIPTION: AC-DC POWER SUPPLY
date 05/13/2021 │ page 4 of 5
EFFICIENCY CURVES (CONTINUED)
MECHANICAL
parameter
conditions/description
dimensions
101.6 x 50.8 x 26.6 (4.0 x 2.0 x 1.17 inch)
min
typ
112
cooling
natural convection
CN100 input connector
CN100 mates with Jowle A3961H02-3P, crimp pin A3961T2P-2C,
or Molex 09-50-3031, crimp pin 2478 series
CN200 output connector
CN200 mates with Jowle A3961H02-4P, crimp pin A3961T2P-2C,
or Molex 09-50-3041, crimp pin 2478 series
MECHANICAL DRAWING
M A IN LA BE L
CN100 Connector
PIN
Function
1
AC(L)
2
NP
3
AC(N)
Trim Pot
CN200 Connector
PIN
Function
1
+V
2
+V
3
RTN
4
RTN
cui.com
units
mm
weight
units: mm
tolerance:
X≤30: ±0.25 mm
30
很抱歉,暂时无法提供与“VOF-50B-12”相匹配的价格&库存,您可以联系我们找货
免费人工找货- 国内价格 香港价格
- 1+294.217561+35.33539