Additional Resources:
Product Page
|
3D Model
date
02/23/2022
page
1 of 4
SERIES: VSBU-120C │ DESCRIPTION: AC-DC POWER SUPPLY
FEATURES
•
•
•
•
•
•
universal input (90 ~ 264 Vac)
up to 120 W continuous power
industry standard 3” x 5” footprint
active power factor correction
IEC/EN/UL 62368 certified
over voltage, over current, short circuit protection
RoHS
MODEL
output
voltage1
output
current
output
power
ripple and
noise
efficiency
(Vdc)
max
(A)
max
(W)
max
(mVp-p)
typ
(%)
5
22.0
110
60
70
VSBU-120C-12
12
10.0
120
130
75
VSBU-120C-15
15
8.0
120
150
78
VSBU-120C-24
24
5.0
120
200
82
VSBU-120C-30
30
4.0
120
250
82
VSBU-120C-36
36
3.33
120
250
82
VSBU-120C-48
48
2.5
120
300
82
VSBU-120C-5
Note:
1. Factory adjustable.
PART NUMBER KEY
VSBU-120C - XXX
Output Voltage
Base Number
cui.com
Additional Resources:
Product Page
|
3D Model
CUI Inc │ SERIES: VSBU-120C │ DESCRIPTION: AC-DC POWER SUPPLY
date 02/23/2022 │ page 2 of 4
INPUT
parameter
conditions/description
min
voltage
typ
90
frequency
47
current
at 100 Vac, full load
at 240 Vac, full load
inrush current
at 100 Vac, 25°C, full load, cold start
at 240 Vac, 25°C, full load, cold start
power factor correction
at 240 Vac, full load
0.95
parameter
conditions/description
min
line regulation
full load
load regulation
at 230 Vac, 10 ~ 90% load
temperature coefficient
all output models, full load, 100 ~ 240 Vac
transient response
start-up
hold-up
full load at 100 Vac
max
units
264
Vac
63
Hz
1.75
0.72
A
A
37
88
A
A
1.0
OUTPUT
typ
max
units
1
%
5
%
0.04
%/°C
full load to half load at 110 Vac
4
ms
full load at 100~240 Vac
3
s
-0.04
16
ms
PROTECTIONS
parameter
conditions/description
min
over voltage protection
over current protection
auto recovery
short circuit protection
auto recovery
max
units
112
typ
132
%
110
150
%
max
units
SAFETY & COMPLIANCE
parameter
conditions/description
isolation voltage
input to output
input to earth ground
min
safety approvals
certified to
UKCA
EMI/EMC
CISPR-32/EN 55032:2012/AC:2013 Class B
EN 61000-3-2:2014
EN 61000-3-3:2013
leakage current
full load at 240 Vac
RoHS compliant
yes
MTBF
as per MIL-HDSK-217F, 25°C
typ
4,242
2,121
Vdc
Vdc
62368: IEC/EN/UL
0.75
100,000
mA
hrs
ENVIRONMENTAL
parameter
conditions/description
operating temperature
see derating curve
min
storage temperature
operating humidity
non-condensing
storage humidity
cui.com
typ
max
units
0
70
°C
-40
85
°C
0
95
%
0
95
%
Additional Resources:
Product Page
CUI Inc │ SERIES: VSBU-120C │ DESCRIPTION: AC-DC POWER SUPPLY
MECHANICAL DRAWING
units: mm[inches]
tolerance: ±0.5mm
Function
1
OUT
2
OUT
3
OUT
4
OUT
5
OUT
6
OUT
7
RTN
8
RTN
9
RTN
10
RTN
11
RTN
12
RTN
13
no connect
3D Model
date 02/23/2022 │ page 3 of 4
DERATING CURVES
PIN
|
Note:
1. Input connector mates with Molex housing 09-52-4054 and
Molex 2478 series crimp terminal.
2. Output connector mates with Molex housing 09-52-4134 and
Molex 2478 series crimp terminal.
cui.com
Additional Resources:
Product Page
|
3D Model
CUI Inc │ SERIES: VSBU-120C │ DESCRIPTION: AC-DC POWER SUPPLY
date 02/23/2022 │ page 4 of 4
REVISION HISTORY
rev.
description
date
1.0
initial release
12/08/2020
1.01
mechanical drawing updated
08/16/2021
1.02
derating curves updated
02/07/2022
UKCA added to specification
02/23/2022
1.03
The revision history provided is for informational purposes only and is believed to be accurate.
Headquarters
20050 SW 112th Ave.
Tualatin, OR 97062
800.275.4899
Fax 503.612.2383
cui.com
techsupport@cui.com
CUI offers a two (2) year limited warranty. Complete warranty information is listed on our website.
CUI reserves the right to make changes to the product at any time without notice. Information provided by CUI is believed to be accurate and reliable. However, no responsibility is
assumed by CUI for its use, nor for any infringements of patents or other rights of third parties which may result from its use.
CUI products are not authorized or warranted for use as critical components in equipment that requires an extremely high level of reliability. A critical
component is any component of a life support device or system whose failure to perform can be reasonably expected to cause the failure of the life support device or system, or to
affect its safety or effectiveness.
很抱歉,暂时无法提供与“VSBU-120C-36”相匹配的价格&库存,您可以联系我们找货
免费人工找货