VSKM-S10-15U

VSKM-S10-15U

  • 厂商:

    CUI

  • 封装:

    -

  • 描述:

    Enclosed AC DC Converter 1 Output 15V 700mA 85 ~ 264 VAC Input

  • 数据手册
  • 价格&库存
VSKM-S10-15U 数据手册
date page 01/19/2012 1 of 4 SERIES: VSKM-S10 Series │ DESCRIPTION: MEDICAL SWITCHING POWER SUPPLY FEATURES • • • • • • • Up to 10 W continuous power Compact board mount design Universal input (85~264 Vac / 120~370 Vdc) Single output from 3.3 to 24 V Over current and short circuit protections Full medical approvals Efficiency up to 80% RoHS MODEL VSKM-S10-3R3U VSKM-S10-5U VSKM-S10-9U VSKM-S10-12U VSKM-S10-15U VSKM-S10-24U Notes: output voltage (Vdc) output current max (A) output power max (W) ripple and noise1 typ (mVp-p) efficiency typ (%) 3.3 5 9 12 15 24 2 2 1.1 0.9 0.7 0.45 6.6 10 10 10 10 10 50 50 50 50 50 50 70 74 76 76 78 80 1. Ripple and noise measured at 20 MHz bandwidth PART NUMBER KEY VSKM-S10 - XXU Base Number Output Voltage cui.com CUI Inc │ SERIES: VSKM-S10 Series │ DESCRIPTION: MEDICAL SWITCHING POWER SUPPLY date 01/19/2012 │ page 2 of 4 INPUT parameter voltage frequency input current inrush current external input fuse (recommended) leakage current at 110 Vac at 230 Vac at 110 Vac at 230 Vac slow blow, 250 V 230 V ac, 50 Hz conditions/description min 85 120 47 230 150 10 20 2 0.1 typ max 264 370 63 units Vac Vdc Hz mA mA A A A mA OUTPUT parameter line regulation load regulation temperature coefficient hold-up time voltage set point accuracy switching frequency at 230 Vac 3.3 V output all other models 10 ~ 100% conditions/description min typ ±0.5 ±1 0.02 50 ±3 ±2 60 max units % % %/°C ms % % kHz PROTECTIONS parameter over current protection short circuit protection auto recovery with no damage from a short on any output conditions/description min typ max 110 units % SAFETY & COMPLIANCE parameter isolation voltage safety approvals safety class EMI/EMC1 RoHS compliant MTBF conditions/description primary to secondary (for 1 minute) IEC 60601-1, EN 60601-1, UL 60601-1 class II EN 55011 (level B), IEC/EN 61000-4-2 level 4 (8kV/15kV), IEC/EN 61000-4-3, IEC/EN 61000-4-4 level 4 (4kV), IEC/EN 61000-4-5 level 4 (2kV/4kV) yes 25°C 300,000 hrs min 4,000 typ max units Vac Notes: 1. external EMC application circuit is required ENVIRONMENTAL parameter operating temperature storage temperature case temperature operating humidity non-condensing conditions/description min -25 -40 typ max 70 105 95 95 units °C °C °C % cui.com CUI Inc │ SERIES: VSKM-S10 Series │ DESCRIPTION: MEDICAL SWITCHING POWER SUPPLY date 01/19/2012 │ page 3 of 4 DERATING CURVES 1. output power vs. ambient temperature 2. output power vs. input voltage ≈ 100 80 60 50 40 20 100 80 60 50 40 20 Load (%) ≈ Load (%) -40 -30 -25 -20 -10 0 10 50 60 70 70 85 110 125 ≈ 210 ≈ 225 240 264 Ambient Temperature (°C) Input Voltage (Vac) MECHANICAL parameter dimensions case material weight conditions/description 2.1 x 1.12 x 0.75 inch (53.5 x 28.5 x 19.0 mm) UL94V-0 47 50 53 g min typ max units MECHANICAL DRAWING units: mm [inches] tolerance: ±0.5 [±0.02] pin section tolerance: ±0.10 mm [±0.004] 53.50 2.106 1.20[0.047] 1 19.00 0.748 3 4 6.00 0.236 (TYP) 1.00 0.039 (TYP) 2 53.50 2.106 2 4 1 45.72 1.800 3 recommended PCB footprint (top view) grid: 2.54 mm (0.10 inch) 10.16 0.400 10.16 0.400 10.16 0.400 28.5 1.122 14.25 0.561 PIN CONNECTIONS PIN FUNCTION 1 AC(N) AC(L) 2 3 +Vo 4 -Vo cui.com CUI Inc │ SERIES: VSKM-S10 Series │ DESCRIPTION: MEDICAL SWITCHING POWER SUPPLY date 01/19/2012 │ page 4 of 4 TYPICAL APPLICATION CIRCUIT *Fuse *NTC L NF *MOV C6 L C7 +Vo C1 C2 TVS + C8 RL -Vo N N EXTERNAL CAPACITORS TYPICAL VALUE (Unit: μF) MODEL VSKM-S10-3R3U VSKM-S10-5U VSKM-S10-9U VSKM-S10-12U VSKM-S10-15U VSKM-S10-24U Notes: C1 220 μF/10 V 220 μF/10 V 120 μF/25 V 120 μF/25 V 120 μF/25 V 68 μF/35 V C2 0.1 μF/50 V 0.1 μF/50 V 0.1 μF/50 V 0.1 μF/50 V 0.1 μF/50 V 0.1 μF/50 V TVS P6KE6.8A P6KE6.8A P6KE12A P6KE20A P6KE20A P6KE30A 1. Output filtering capacitor C1 is an electrolytic capacitor. It is recommended to use high frequency and low impedance electrolytic capacitors. For capacitance and current of capacitor please refer to manufacture’s datasheet. Voltage derating of capacitor should be 80% or above. C2 is ceramic capacitor, it is used to filter high frequency noise. TVS is a recommended component to protect post-circuits (if converter fails). 2. MOV is required to protect the device under surge. 2. It is recommended to use a 2A/250V slow blow FUSE. External input NTC is recommended to use 5D-9. 3. If EMC performance is required, it is recommended to add “EMC filter” at the input end (see EMC Application Figure). C6: X capacitor, recommended parameter 0.1μF/275V; C7,C8: Y capacitor, recommended parameter 2200pF/400V; NF: common model choke, recommended inductance is about 10mH-30mH. REVISION HISTORY rev. 1.0 description initial release date 01/16/2012 The revision history provided is for informational purposes only and is believed to be accurate. Headquarters 20050 SW 112th Ave. Tualatin, OR 97062 800.275.4899 CUI offers a two (2) year limited warranty. Complete warranty information is listed on our website. Fax 503.612.2383 cui.com techsupport@cui.com CUI reserves the right to make changes to the product at any time without notice. Information provided by CUI is believed to be accurate and reliable. However, no responsibility is assumed by CUI for its use, nor for any infringements of patents or other rights of third parties which may result from its use. CUI products are not authorized or warranted for use as critical components in equipment that requires an extremely high level of reliability. A critical component is any component of a life support device or system whose failure to perform can be reasonably expected to cause the failure of the life support device or system, or to affect its safety or effectiveness.
VSKM-S10-15U 价格&库存

很抱歉,暂时无法提供与“VSKM-S10-15U”相匹配的价格&库存,您可以联系我们找货

免费人工找货