OLS5 Series
Optical liquid level sensor M10 mount
Low cost sensors for general liquid sensing
High reliability optical sensing
Internal mount via M10x1 thread
Standard temperature range -25ºC to +80ºC
Extended temperature range -40ºC to +125ºC
High and Low output versions
Technical Specification
The OLS5 series is a liquid level sensor for
single point liquid level detection.
The sensor has an infra-red emitter and
detector aligned within an accurately
shaped cone to give good optical coupling
when the sensor is in air. This coupling is
greatly reduced, when the sensor is
immersed in liquid, as the infra-red light
escapes through the liquid rather than
being reflected back to the detector.
The sensor has a transistor output, so can
be configured by the user for particular
applications.
Output is via TTL compatible push pull
output.
Mounting style
Internal
Mounting thread
M10x1
Body material
Polysulfone UDEL 1700
Temperature Range
-25 to +80ºC/-40º to +125ºC
Maximum pressure
20 bar
Tightening torque for fixing1.5Nm/13.26lbs in
Electrical Specification
Supply Voltage (Vs)
Vdc
Supply Current Max (Is) mA
Output type
Output Voltage (Vout) @ Iout=100mA
Output Sink & Source Current Iout
Cable length - standard
25cm
Wire size
24AWG
Cable conductor material Tinned copper
Wire sheath material
PTFE
Wire temperature rating
125ºC
Sealing gasket Not supplied
4.5 to 15.4
2.5 (Vs = 15.4Vdc)
Voltage High or Low
Output High Vout = Vs-1V max Output Low Vout = 0.5Vmax
100mA max
Sensor connections
Red= supply +ve, Blue= common(0V), Green= Output
Standard Parts
OLS500D3
OLS500D3L
OLS510D3
OLS510D3L
Mount
M10x1
M10x1
M10x1
M10x1
Temp Range ºC
-25 to +80
-25 to +80
-40 to +125
-40 to +125
Supply Volts V
5 to 15dc
5 to 15dc
5 to 15dc
5 to 15dc
Output
High in air
Low in air
High in air
Low in air
Custom versions can be made for particular applications. Please contact Cynergy3 with your requirements.
Mechanical Dimensions
M10x1 Thread
Ø 12
Ø 10
22.70
Cynergy3 Components Ltd.
7 Cobham Road
Ferndown Industrial Estate
Wimborne, Dorset BH21 7PE
Telephone +44 (0) 1202 897969
Email:sales@cynergy3.com
ISO9001 C E R T I F I E D
www.cynergy3.com
© 2012 Cynergy3 Components, All Rights Reserved. Specifications are subject to change without prior notice. Cynergy3 Components and the Cynergy3 Components logo are trademarks of Cynergy3 Components Limited.
OLS5 Series
Optical liquid level sensor M10 mount
Installation
The sensor can be mounted in either the side or the bottom of a tank. It must not be mounted in the top of a tank with
the cone downwards.
This sensor requires a hole of 10mm minimum or an M10x1 thread socket connection. The hole should be in a flat
surface and be free of burrs.
The sensor with suitable gasket should be inserted into the hole and a fixing nut fitted on the M10 thread on the outside
of the tank. Alternatively the sensor can be screwed into a M10x1 socket. The sensor should not be overtightened.
Cleaning
Proper fluids should be selected based on the type of contamination to be removed. It is recommended that freon or
alcohol based solvents are used.
DO NOT USE chlorinated solvents such as trichloroethylene as these are likely to attack the sensor housing material.
Liquid Media Compatibility
Check that the fluid in which you wish to use the sensor is compatible with Polysulfone.
Installation in M10x1 socket
Installation with back nut
“O” ring gasket
Fixing nut M10x1
M10x1 socket
Red wire =Vs
Green wire =Output
Blue wire = 0V
Cynergy3 Components Ltd.
7 Cobham Road
Ferndown Industrial Estate
Wimborne, Dorset BH21 7PE
Telephone +44 (0) 1202 897969
Email:sales@cynergy3.com
ISO9001 C E R T I F I E D
www.cynergy3.com
© 2012 Cynergy3 Components, All Rights Reserved. Specifications are subject to change without prior notice. Cynergy3 Components and the Cynergy3 Components logo are trademarks of Cynergy3 Components Limited.
很抱歉,暂时无法提供与“OLS510D3”相匹配的价格&库存,您可以联系我们找货
免费人工找货