FM24CL64B
64-Kbit (8K × 8) Serial (I2C) F-RAM
64-Kbit (8K × 8) Serial (I2C) F-RAM
Features
■
■
Functional Description
64-Kbit ferroelectric random access memory (F-RAM) logically
organized as 8K × 8
14
❐ High-endurance 100 trillion (10 ) read/writes
❐ 151-year data retention (See Data Retention and Endurance
on page 10)
❐ NoDelay™ writes
❐ Advanced high-reliability ferroelectric process
The FM24CL64B is a 64-Kbit nonvolatile memory employing an
advanced ferroelectric process. A ferroelectric random access
memory or F-RAM is nonvolatile and performs reads and writes
similar to a RAM. It provides reliable data retention for 151 years
while eliminating the complexities, overhead, and system-level
reliability problems caused by EEPROM and other nonvolatile
memories.
Fast 2-wire Serial interface (I2C)
❐ Up to 1-MHz frequency
2
❐ Direct hardware replacement for serial (I C) EEPROM
❐ Supports legacy timings for 100 kHz and 400 kHz
Unlike EEPROM, the FM24CL64B performs write operations at
bus speed. No write delays are incurred. Data is written to the
memory array immediately after each byte is successfully
transferred to the device. The next bus cycle can commence
without the need for data polling. In addition, the product offers
substantial write endurance compared with other nonvolatile
memories. Also, F-RAM exhibits much lower power during writes
than EEPROM since write operations do not require an internally
elevated power supply voltage for write circuits. The
FM24CL64B is capable of supporting 1014 read/write cycles, or
100 million times more write cycles than EEPROM.
■
Low power consumption
❐ 100 A (typ) active current at 100 kHz
❐ 3 A (typ) standby current
■
Voltage operation: VDD = 2.7 V to 3.65 V
■
Industrial temperature: –40 C to +85 C
■
Packages
❐ 8-pin small outline integrated circuit (SOIC) package
❐ 8-pin thin dual flat no leads (DFN) package
■
Restriction of hazardous substances (RoHS) compliant
These capabilities make the FM24CL64B ideal for nonvolatile
memory applications, requiring frequent or rapid writes.
Examples range from data logging, where the number of write
cycles may be critical, to demanding industrial controls where the
long write time of EEPROM can cause data loss. The
combination of features allows more frequent data writing with
less overhead for the system.
The FM24CL64B provides substantial benefits to users of serial
(I2C) EEPROM as a hardware drop-in replacement. The device
specifications are guaranteed over an industrial temperature
range of –40 C to +85 C.
For a complete list of related documentation, click here.
Logic Block Diagram
Address
Latch
Counter
8Kx8
F-RAM Array
13
8
SDA
Serial to Parallel
Converter
Data Latch
8
SCL
WP
Control Logic
A2-A0
Cypress Semiconductor Corporation
Document Number: 001-84458 Rev. *K
•
198 Champion Court
•
San Jose, CA 95134-1709
•
408-943-2600
Revised December 5, 2018
FM24CL64B
Contents
Pinouts .............................................................................. 3
Pin Definitions .................................................................. 3
Functional Overview ........................................................ 4
Memory Architecture ........................................................ 4
I2C Interface ...................................................................... 4
STOP Condition (P) ..................................................... 4
START Condition (S) ................................................... 4
Data/Address Transfer ................................................ 5
Acknowledge/No-acknowledge ................................... 5
Slave Device Address ................................................. 6
Addressing Overview .................................................. 6
Data Transfer .............................................................. 6
Memory Operation ............................................................ 6
Write Operation ........................................................... 6
Read Operation ........................................................... 7
Endurance ......................................................................... 8
Maximum Ratings ............................................................. 9
Operating Range ............................................................... 9
DC Electrical Characteristics .......................................... 9
Data Retention and Endurance ..................................... 10
Document Number: 001-84458 Rev. *K
Capacitance .................................................................... 10
Thermal Resistance ........................................................ 10
AC Test Loads and Waveforms ..................................... 10
AC Test Conditions ........................................................ 10
AC Switching Characteristics ....................................... 11
Power Cycle Timing ....................................................... 12
Ordering Information ...................................................... 13
Ordering Code Definitions ......................................... 13
Package Diagrams .......................................................... 14
Acronyms ........................................................................ 16
Document Conventions ................................................. 16
Units of Measure ....................................................... 16
Document History Page ................................................. 17
Sales, Solutions, and Legal Information ...................... 19
Worldwide Sales and Design Support ....................... 19
Products .................................................................... 19
PSoC® Solutions ...................................................... 19
Cypress Developer Community ................................. 19
Technical Support ..................................................... 19
Page 2 of 19
FM24CL64B
Pinouts
Figure 1. 8-pin SOIC pinout
A0
1
A1
2
A2
3
VSS
4
Top View
not to scale
8
VDD
7
WP
6
SCL
5
SDA
Figure 2. 8-pin DFN pinout
O
A0
1
A1
2
8
VDD
7
WP
EXPOSED
PAD
A2
3
6
SCL
VSS
4
5
SDA
Top View
not to scale
Pin Definitions
Pin Name
I/O Type
Description
A2–A0
Input
Device Select Address 2–0. These pins are used to select one of up to 8 devices of the same type
on the same I2C bus. To select the device, the address value on the three pins must match the
corresponding bits contained in the slave address. The address pins are pulled down internally.
SDA
Input/Output Serial Data/Address. This is a bi-directional pin for the I2C interface. It is open-drain and is intended
to be wire-AND’d with other devices on the I2C bus. The input buffer incorporates a Schmitt trigger for
noise immunity and the output driver includes slope control for falling edges. An external pull-up resistor
is required.
SCL
Input
Serial Clock. The serial clock pin for the I2C interface. Data is clocked out of the device on the falling
edge, and into the device on the rising edge. The SCL input also incorporates a Schmitt trigger input
for noise immunity.
WP
Input
Write Protect. When tied to VDD, addresses in the entire memory map will be write-protected. When
WP is connected to ground, all addresses are write enabled. This pin is pulled down internally.
VSS
Power supply Ground for the device. Must be connected to the ground of the system.
VDD
Power supply Power supply input to the device.
EXPOSED
PAD
No connect
The EXPOSED PAD on the bottom of 8-pin DFN package is not connected to the die. The EXPOSED
PAD should not be soldered on the PCB.
Document Number: 001-84458 Rev. *K
Page 3 of 19
FM24CL64B
Functional Overview
a new bus transaction can be shifted into the device, a write
operation is complete. This is explained in more detail in the
interface section.
The FM24CL64B is a serial F-RAM memory. The memory array
is logically organized as 8,192 × 8 bits and is accessed using an
industry-standard I2C interface. The functional operation of the
F-RAM is similar to serial (I2C) EEPROM. The major difference
between the FM24CL64B and a serial (I2C) EEPROM with the
same pinout is the F-RAM’s superior write performance, high
endurance, and low power consumption.
I2C Interface
The FM24CL64B employs a bi-directional I2C bus protocol using
few pins or board space. Figure 3 illustrates a typical system
configuration using the FM24CL64B in a microcontroller-based
system. The industry standard I2C bus is familiar to many users
but is described in this section.
Memory Architecture
By convention, any device that is sending data onto the bus is
the transmitter while the target device for this data is the receiver.
The device that is controlling the bus is the master. The master
is responsible for generating the clock signal for all operations.
Any device on the bus that is being controlled is a slave. The
FM24CL64B is always a slave device.
When accessing the FM24CL64B, the user addresses 8K
locations of eight data bits each. These eight data bits are shifted
in or out serially. The addresses are accessed using the I2C
protocol, which includes a slave address (to distinguish other
non-memory devices) and a two-byte address. The upper 3 bits
of the address range are 'don't care' values. The complete
address of 13 bits specifies each byte address uniquely.
The bus protocol is controlled by transition states in the SDA and
SCL signals. There are four conditions including START, STOP,
data bit, or acknowledge. Figure 4 on page 5 and Figure 5 on
page 5 illustrates the signal conditions that specify the four
states. Detailed timing diagrams are shown in the electrical
specifications section.
The access time for the memory operation is essentially zero,
beyond the time needed for the serial protocol. That is, the
memory is read or written at the speed of the I2C bus. Unlike a
serial (I2C) EEPROM, it is not necessary to poll the device for a
ready condition because writes occur at bus speed. By the time
Figure 3. System Configuration using Serial (I2C) nvSRAM
RPmin = (VDD - VOLmax) / IOL
V DD
RPmax = tr / (0.8473 * Cb)
SDA
Microcontroller
SCL
V DD
V DD
A0
A1
A2
SCL
A0
SCL
A0
SCL
SDA
A1
SDA
A1
SDA
WP
A2
WP
#0
#1
A2
WP
#7
STOP Condition (P)
START Condition (S)
A STOP condition is indicated when the bus master drives SDA
from LOW to HIGH while the SCL signal is HIGH. All operations
using the FM24CL64B should end with a STOP condition. If an
operation is in progress when a STOP is asserted, the operation
will be aborted. The master must have control of SDA in order to
assert a STOP condition.
A START condition is indicated when the bus master drives SDA
from HIGH to LOW while the SCL signal is HIGH. All commands
should be preceded by a START condition. An operation in
progress can be aborted by asserting a START condition at any
time. Aborting an operation using the START condition will ready
the FM24CL64B for a new operation.
If during operation the power supply drops below the specified
VDD minimum, the system should issue a START condition prior
to performing another operation.
Document Number: 001-84458 Rev. *K
Page 4 of 19
FM24CL64B
Figure 4. START and STOP Conditions
full pagewidth
SDA
SDA
SCL
SCL
S
P
STOP Condition
START Condition
Figure 5. Data Transfer on the I2C Bus
handbook, full pagewidth
P
SDA
Acknowledgement
signal from slave
MSB
SCL
S
1
2
7
9
8
1
Acknowledgement
signal from receiver
2
3
4-8
ACK
START
condition
9
ACK
All data transfers (including addresses) take place while the SCL
signal is HIGH. Except under the three conditions described
above, the SDA signal should not change while SCL is HIGH.
Acknowledge/No-acknowledge
The acknowledge takes place after the 8th data bit has been
transferred in any transaction. During this state the transmitter
should release the SDA bus to allow the receiver to drive it. The
receiver drives the SDA signal LOW to acknowledge receipt of
the byte. If the receiver does not drive SDA LOW, the condition
is a no-acknowledge and the operation is aborted.
S
or
P
STOP or
START
condition
Byte complete
Data/Address Transfer
S
The receiver would fail to acknowledge for two distinct reasons.
First is that a byte transfer fails. In this case, the no-acknowledge
ceases the current operation so that the device can be
addressed again. This allows the last byte to be recovered in the
event of a communication error.
Second and most common, the receiver does not acknowledge
to deliberately end an operation. For example, during a read
operation, the FM24CL64B will continue to place data onto the
bus as long as the receiver sends acknowledges (and clocks).
When a read operation is complete and no more data is needed,
the receiver must not acknowledge the last byte. If the receiver
acknowledges the last byte, this will cause the FM24CL64B to
attempt to drive the bus on the next clock while the master is
sending a new command such as STOP.
Figure 6. Acknowledge on the I2C Bus
handbook, full pagewidth
DATA OUTPUT
BY MASTER
No Acknowledge
DATA OUTPUT
BY SLAVE
Acknowledge
SCL FROM
MASTER
1
2
8
9
S
START
Condition
Document Number: 001-84458 Rev. *K
Clock pulse for
acknowledgement
Page 5 of 19
FM24CL64B
Slave Device Address
acknowledge occurs, the FM24CL64B will transfer the next
sequential byte. If the acknowledge is not sent, the FM24CL64B
will end the read operation. For a write operation, the
FM24CL64B will accept 8 data bits from the master then send an
acknowledge. All data transfer occurs MSB (most significant bit)
first.
The first byte that the FM24CL64B expects after a START
condition is the slave address. As shown in Figure 7, the slave
address contains the device type or slave ID, the device select
address bits, and a bit that specifies if the transaction is a read
or a write.
Memory Operation
Bits 7-4 are the device type (slave ID) and should be set to 1010b
for the FM24CL64B. These bits allow other function types to
reside on the I2C bus within an identical address range. Bits 3-1
are the device select address bits. They must match the corresponding value on the external address pins to select the device.
Up to eight FM24CL64B devices can reside on the same I2C bus
by assigning a different address to each. Bit 0 is the read/write
bit (R/W). R/W = ‘1’ indicates a read operation and R/W = ‘0’
indicates a write operation.
The FM24CL64B is designed to operate in a manner very similar
to other I2C interface memory products. The major differences
result from the higher performance write capability of F-RAM
technology. These improvements result in some differences
between the FM24CL64B and a similar configuration EEPROM
during writes. The complete operation for both writes and reads
is explained below.
Write Operation
Figure 7. Memory Slave Device Address
MSB
handbook, halfpage
1
All writes begin with a slave address, then a memory address.
The bus master indicates a write operation by setting the LSB of
the slave address (R/W bit) to a ‘0’. After addressing, the bus
master sends each byte of data to the memory and the memory
generates an acknowledge condition. Any number of sequential
bytes may be written. If the end of the address range is reached
internally, the address counter will wrap from 1FFFh to 0000h.
LSB
0
1
Slave ID
0
A2
A1
A0 R/W
Device Select
Addressing Overview
Unlike other nonvolatile memory technologies, there is no
effective write delay with F-RAM. Since the read and write
access times of the underlying memory are the same, the user
experiences no delay through the bus. The entire memory cycle
occurs in less time than a single bus clock. Therefore, any
operation including read or write can occur immediately following
a write. Acknowledge polling, a technique used with EEPROMs
to determine if a write is complete is unnecessary and will always
return a ready condition.
After the FM24CL64B (as receiver) acknowledges the slave
address, the master can place the memory address on the bus
for a write operation. The address requires two bytes. The
complete 13-bit address is latched internally. Each access
causes the latched address value to be incremented automatically. The current address is the value that is held in the latch;
either a newly written value or the address following the last
access. The current address will be held for as long as power
remains or until a new value is written. Reads always use the
current address. A random read address can be loaded by
beginning a write operation as explained below.
Internally, an actual memory write occurs after the 8th data bit is
transferred. It will be complete before the acknowledge is sent.
Therefore, if the user desires to abort a write without altering the
memory contents, this should be done using START or STOP
condition prior to the 8th data bit. The FM24CL64B uses no page
buffering.
After transmission of each data byte, just prior to the
acknowledge, the FM24CL64B increments the internal address
latch. This allows the next sequential byte to be accessed with
no additional addressing. After the last address (1FFFh) is
reached, the address latch will roll over to 0000h. There is no
limit to the number of bytes that can be accessed with a single
read or write operation.
The memory array can be write-protected using the WP pin.
Setting the WP pin to a HIGH condition (VDD) will write-protect
all addresses. The FM24CL64B will not acknowledge data bytes
that are written to protected addresses. In addition, the address
counter will not increment if writes are attempted to these
addresses. Setting WP to a LOW state (VSS) will disable the write
protect. WP is pulled down internally.
Data Transfer
After the address bytes have been transmitted, data transfer
between the bus master and the FM24CL64B can begin. For a
read operation the FM24CL64B will place 8 data bits on the bus
then wait for an acknowledge from the master. If the
Figure 8 and Figure 9 on page 7 below illustrate a single-byte
and multiple-byte write cycles.
Figure 8. Single-Byte Write
By Master
Start
S
Stop
Address & Data
Slave Address
By F-RAM
Document Number: 001-84458 Rev. *K
0 A
Address MSB
A
Address LSB
A
Data Byte
A
P
Acknowledge
Page 6 of 19
FM24CL64B
Figure 9. Multi-Byte Write
Start
Stop
Address & Data
By Master
S
Slave Address
0 A
Address MSB
By F-RAM
A
Address LSB
A
Data Byte
A
Data Byte
A
P
Acknowledge
Read Operation
There are two basic types of read operations. They are current
address read and selective address read. In a current address
read, the FM24CL64B uses the internal address latch to supply
the address. In a selective read, the user performs a procedure
to set the address to a specific value.
Current Address & Sequential Read
As mentioned above the FM24CL64B uses an internal latch to
supply the address for a read operation. A current address read
uses the existing value in the address latch as a starting place
for the read operation. The system reads from the address
immediately following that of the last operation.
To perform a current address read, the bus master supplies a
slave address with the LSB set to a ‘1’. This indicates that a read
operation is requested. After receiving the complete slave
address, the FM24CL64B will begin shifting out data from the
current address on the next clock. The current address is the
value held in the internal address latch.
Beginning with the current address, the bus master can read any
number of bytes. Thus, a sequential read is simply a current
address read with multiple byte transfers. After each byte the
internal address counter will be incremented.
Note Each time the bus master acknowledges a byte, this
indicates that the FM24CL64B should read out the next
sequential byte.
There are four ways to properly terminate a read operation.
Failing to properly terminate the read will most likely create a bus
contention as the FM24CL64B attempts to read out additional
data onto the bus. The four valid methods are:
1. The bus master issues a no-acknowledge in the 9th clock
cycle and a STOP in the 10th clock cycle. This is illustrated in
the diagrams below. This is preferred.
2. The bus master issues a no-acknowledge in the 9th clock
cycle and a START in the 10th.
3. The bus master issues a STOP in the 9th clock cycle.
4. The bus master issues a START in the 9th clock cycle.
If the internal address reaches 1FFFh, it will wrap around to
0000h on the next read cycle. Figure 10 and Figure 11 below
show the proper operation for current address reads.
Figure 10. Current Address Read
By Master
Start
No
Acknowledge
Address
Stop
S
Slave Address
By F-RAM
1 A
Acknowledge
Data Byte
1
P
Data
Figure 11. Sequential Read
By Master
Start
No
Acknowledge
Acknowledge
Address
Stop
S
Slave Address
By F-RAM
Document Number: 001-84458 Rev. *K
1 A
Acknowledge
Data Byte
A
Data Byte
1 P
Data
Page 7 of 19
FM24CL64B
Selective (Random) Read
There is a simple technique that allows a user to select a random
address location as the starting point for a read operation. This
involves using the first three bytes of a write operation to set the
internal address followed by subsequent read operations.
To perform a selective read, the bus master sends out the slave
address with the LSB (R/W) set to 0. This specifies a write
operation. According to the write protocol, the bus master then
sends the address bytes that are loaded into the internal address
latch. After the FM24CL64B acknowledges the address, the bus
master issues a START condition. This simultaneously aborts
the write operation and allows the read command to be issued
with the slave address LSB set to a ‘1’. The operation is now a
current address read.
Figure 12. Selective (Random) Read
Start
Address
By Master
Start
No
Acknowledge
Address
Stop
S
Slave Address
0 A
By F-RAM
Address MSB
A
Address LSB
Acknowledge
Endurance
The FM24C64B internally operates with a read and restore
mechanism. Therefore, endurance cycles are applied for each
read or write cycle. The memory architecture is based on an
array of rows and columns. Each read or write access causes an
endurance cycle for an entire row. In the FM24C64B, a row is 64
bits wide. Every 8-byte boundary marks the beginning of a new
Document Number: 001-84458 Rev. *K
A
S
Slave Address
1 A
Data Byte
1 P
Data
row. Endurance can be optimized by ensuring frequently
accessed data is located in different rows. Regardless, FRAM
read and write endurance is effectively unlimited at the 1MHz I2C
speed. Even at 3000 accesses per second to the same segment,
10 years time will elapse before 1 trillion endurance cycles occur.
Page 8 of 19
FM24CL64B
Maximum Ratings
Exceeding maximum ratings may shorten the useful life of the
device. These user guidelines are not tested.
Storage temperature ................................ –65 °C to +125 °C
Maximum accumulated storage time
At 125 °C ambient temperature ................................. 1000 h
At 85 °C ambient temperature ................................ 10 Years
Ambient temperature
with power applied ................................... –55 °C to +125 °C
Supply voltage on VDD relative to VSS .........–1.0 V to +5.0 V
Input voltage .......... –1.0 V to + 5.0 V and VIN < VDD + 1.0 V
Package power dissipation capability
(TA = 25 °C) ................................................................. 1.0 W
Surface mount lead soldering temperature
(10 seconds) ............................................................ +260 °C
Electrostatic Discharge Voltage [1]
Human Body Model (AEC-Q100-002 Rev. E) ..................... 2 kV
Charged Device Model (AEC-Q100-011 Rev. B) ................ 500 V
Latch-up current .................................................... > 140 mA
* Exception: The “VIN < VDD + 1.0 V” restriction does not apply
to the SCL and SDA inputs.
Operating Range
DC voltage applied to outputs
in High-Z state .................................... –0.5 V to VDD + 0.5 V
Range
Ambient Temperature (TA)
VDD
Industrial
–40 C to +85 C
2.7 V to 3.65 V
Transient voltage (< 20 ns)
on any pin to ground potential ............ –2.0 V to VDD + 2.0 V
DC Electrical Characteristics
Over the Operating Range
Parameter
Description
VDD
Power supply
IDD
Average VDD current
Test Conditions
SCL toggling
between
VDD – 0.3 V and VSS,
other inputs VSS or
VDD – 0.3 V.
Min
Typ [2]
Max
Unit
2.7
3.3
3.65
V
fSCL = 100 kHz
–
–
100
A
fSCL = 400 kHz
–
–
170
A
fSCL = 1 MHz
–
–
300
A
ISB
Standby current
SCL = SDA = VDD. All
other inputs VSS or
VDD. Stop command
issued.
–
3
6
A
ILI
Input leakage current
(Except WP and A2–A0)
VSS < VIN < VDD
–1
–
+1
A
Input leakage current
(for WP and A2–A0)
VSS < VIN < VDD
–1
–
+100
A
ILO
Output leakage current
VSS < VIN < VDD
–1
–
+1
A
VIH
Input HIGH voltage
0.7 × VDD
–
VDD + 0.3
V
VIL
Input LOW voltage
–0.3
–
0.3 × VDD
V
V
VOL
Rin
[3]
VHYS[4]
Output LOW voltage
IOL = 3 mA
–
–
0.4
Input resistance (WP, A2–A0)
For VIN = VIL (Max)
40
–
–
k
For VIN = VIH (Min)
1
–
–
M
0.05 × VDD
–
–
V
Input hysteresis
Notes
1. Electrostatic Discharge voltages specified in the datasheet are the JEDEC standard limits used for qualifying the device. To know the maximum value device passes
for, please refer to the device qualification report available on the website.
2. Typical values are at 25 °C, VDD = VDD (typ). Not 100% tested.
3. The input pull-down circuit is strong (40 k) when the input voltage is below VIL and weak (1 M) when the input voltage is above VIH.
4. This parameter is guaranteed by design and is not tested.
Document Number: 001-84458 Rev. *K
Page 9 of 19
FM24CL64B
Data Retention and Endurance
Parameter
TDR
NVC
Description
Test condition
Data retention
Endurance
Min
Max
Unit
TA = 85 C
10
–
Years
TA = 75 C
38
–
TA = 65 C
151
–
14
–
Over operating temperature
10
Cycles
Capacitance
Parameter [5]
Description
Test Conditions
CO
Output pin capacitance (SDA)
CI
Input pin capacitance
TA = 25 C, f = 1 MHz, VDD = VDD(typ)
Max
Unit
8
pF
6
pF
Thermal Resistance
Parameter [5]
Description
JA
Thermal resistance
(junction to ambient)
JC
Thermal resistance
(junction to case)
Test Conditions
8-pin SOIC
8-pin DFN
Unit
Test conditions follow standard test
methods and procedures for measuring
thermal impedance, per EIA/JESD51.
147
28
C/W
47
30
C/W
AC Test Loads and Waveforms
Figure 13. AC Test Loads and Waveforms
3.6 V
1.1 k
OUTPUT
100 pF
AC Test Conditions
Input pulse levels .................................10% and 90% of VDD
Input rise and fall times .................................................10 ns
Input and output timing reference levels ................0.5 × VDD
Output load capacitance ............................................ 100 pF
Note
5. This parameter is periodically sampled and not 100% tested.
Document Number: 001-84458 Rev. *K
Page 10 of 19
FM24CL64B
AC Switching Characteristics
Over the Operating Range
Parameter [6]
Description
Cypress
Alt.
Parameter Parameter
Min
Max
Min
Max
Min
Max
Unit
–
0.1
–
0.4
–
1.0
MHz
fSCL[7]
SCL clock frequency
tSU; STA
Start condition setup for repeated Start
4.7
–
0.6
–
0.25
–
s
tHD;STA
Start condition hold time
4.0
–
0.6
–
0.25
–
s
tLOW
Clock LOW period
4.7
–
1.3
–
0.6
–
s
tHIGH
Clock HIGH period
4.0
–
0.6
–
0.4
–
s
tSU;DAT
tSU;DATA
Data in setup
250
–
100
–
100
–
ns
tHD;DAT
tHD;DATA
Data in hold
0
–
0
–
0
–
ns
Data output hold (from SCL @ VIL)
0
–
0
–
0
–
ns
–
1000
–
300
–
300
ns
tDH
[8]
tr
Input rise time
tF[8]
tf
Input fall time
tR
–
300
–
300
–
100
ns
4.0
–
0.6
–
0.25
–
s
SCL LOW to SDA Data Out Valid
–
3
–
0.9
–
0.55
s
tBUF
Bus free before new transmission
4.7
–
1.3
–
0.5
–
s
tSP
Noise suppression time constant on SCL, SDA
–
50
–
50
–
50
ns
tSU;STO
tAA
STOP condition setup
tVD;DATA
Figure 14. Read Bus Timing Diagram
tR
`
tF
tHIGH
tSP
tLOW
tSP
SCL
tSU:SDA
1/fSCL
tBUF
tHD:DAT
tSU:DAT
SDA
tDH
tAA
Stop Start
Start
Acknowledge
Figure 15. Write Bus Timing Diagram
tHD:DAT
SCL
tHD:STA
tSU:STO
tSU:DAT
tAA
SDA
Start
Stop Start
Acknowledge
Notes
6. Test conditions assume signal transition time of 10 ns or less, timing reference levels of VDD/2, input pulse levels of 0 to VDD(typ), and output loading of the specified
IOL and load capacitance shown in Figure 13.
7. The speed-related specifications are guaranteed characteristic points along a continuous curve of operation from DC to fSCL (max).
8. These parameters are guaranteed by design and are not tested.
Document Number: 001-84458 Rev. *K
Page 11 of 19
FM24CL64B
Power Cycle Timing
Over the Operating Range
Parameter
Description
Min
Max
Unit
tPU
Power-up VDD(min) to first access (START condition)
1
–
ms
tPD
Last access (STOP condition) to power-down (VDD(min))
0
–
µs
tVR [9, 10]
VDD power-up ramp rate
30
–
µs/V
tVF [9, 10]
VDD power-down ramp rate
30
–
µs/V
VDD
~
~
Figure 16. Power Cycle Timing
VDD(min)
tVR
SDA
I2 C START
tVF
tPD
~
~
tPU
VDD(min)
I2 C STOP
Note
9. Slope measured at any point on the VDD waveform.
10. Guaranteed by design.
Document Number: 001-84458 Rev. *K
Page 12 of 19
FM24CL64B
Ordering Information
Package
Diagram
Ordering Code
FM24CL64B-G
51-85066
Package Type
8-pin SOIC
Operating
Range
Industrial
FM24CL64B-GTR
FM24CL64B-DG
001-85260 8-pin DFN
FM24CL64B-DGTR
All these parts are Pb-free. Contact your local Cypress sales representative for availability of these parts.
Ordering Code Definitions
FM 24 CL
64
B - G
X
Option: X = blank or TR
blank = Standard; TR = Tape and Reel
Package Type: X = G or DG
G = 8-pin SOIC; DG = 8-pin DFN
Die Revision
Density: 64 = 64-kbit
Voltage: CL = 2.7 V to 3.65 V
I2C F-RAM
Cypress
Document Number: 001-84458 Rev. *K
Page 13 of 19
FM24CL64B
Package Diagrams
Figure 17. 8-pin SOIC (150 Mils) Package Outline, 51-85066
51-85066 *I
Document Number: 001-84458 Rev. *K
Page 14 of 19
FM24CL64B
Package Diagrams (continued)
Figure 18. 8-pin DFN (4.0 × 4.5 × 0.8 mm) Package Outline, 001-85260
001-85260 *B
Document Number: 001-84458 Rev. *K
Page 15 of 19
FM24CL64B
Acronyms
Acronym
Document Conventions
Description
Units of Measure
ACK
Acknowledge
CMOS
Complementary Metal Oxide Semiconductor
°C
degree Celsius
EIA
Electronic Industries Alliance
Hz
hertz
I2C
Inter-Integrated Circuit
Kb
1024 bit
I/O
Input/Output
kHz
kilohertz
JEDEC
Joint Electron Devices Engineering Council
k
kilohm
LSB
Least Significant Bit
MHz
megahertz
MSB
Most Significant Bit
M
megaohm
NACK
No Acknowledge
A
microampere
RoHS
Restriction of Hazardous Substances
s
microsecond
R/W
Read/Write
mA
milliampere
SCL
Serial Clock Line
ms
millisecond
ns
nanosecond
SDA
Serial Data Access
ohm
SOIC
Small Outline Integrated Circuit
%
percent
WP
Write Protect
pF
picofarad
DFN
Dual Flat No-lead
V
volt
W
watt
Document Number: 001-84458 Rev. *K
Symbol
Unit of Measure
Page 16 of 19
FM24CL64B
Document History Page
Document Title: FM24CL64B, 64-Kbit (8K × 8) Serial (I2C) F-RAM
Document Number: 001-84458
Rev.
ECN No.
Orig. of
Change
Submission
Date
**
3902082
GVCH
02/25/2013
New spec.
*A
3924523
GVCH
03/07/2013
Updated Power Cycle Timing:
Changed minimum value of tPU parameter from 10 ms to 1 ms.
Description of Change
*B
3996669
GVCH
05/13/2013
Added Appendix A - Errata for FM24CL64B.
*C
4045469
GVCH
06/30/2013
Removed Errata (All errata items are fixed).
*D
4283420
GVCH
02/19/2014
Updated Pinouts:
Updated Figure 2 (Added EXPOSED PAD details).
Updated Pin Definitions:
Added EXPOSED PAD pin and its corresponding details.
Updated Maximum Ratings:
Added “Maximum Junction Temperature” and its corresponding details.
Added “DC voltage applied to outputs in High-Z state” and its corresponding
details.
Added “Transient voltage (< 20 ns) on any pin to ground potential” and its
corresponding details.
Added “Package power dissipation capability (TA = 25 °C)” and its
corresponding details.
Added “Latch-up Current” and its corresponding details.
Removed “Package Moisture Sensitivity Level” and its corresponding details.
Updated DC Electrical Characteristics:
Removed existing details of ILI parameter and splitted ILI parameter into two
rows namely “Input leakage current (Except WP and A2–A0)” and “Input
leakage current (for WP and A2–A0)” and added corresponding values.
Updated Data Retention and Endurance:
Removed details of TDR parameter corresponding to “TA = +80 °C”.
Added details of TDR parameter corresponding to “TA = 65 °C”.
Added NVC parameter and its details.
Added Thermal Resistance.
Updated Package Diagrams:
Removed SOIC Package Marking Scheme.
Removed “Ramtron Revision History”.
Updated to Cypress template.
Completing Sunset Review.
*E
4564960
GVCH
11/10/2014
Updated Functional Description:
Added “For a complete list of related documentation, click here.” at the end.
*F
4771539
GVCH
05/20/2015
Replaced “TDFN” with “DFN” in all instances across the document.
Updated Pin Definitions:
Updated details in “Description” column corresponding to “EXPOSED PAD”.
Updated Ordering Information:
Fixed Typo (Replaced “001-85066” with “51-85066” in “Package Diagram”
column).
Updated part numbers (Added part numbers namely FM24CL64B-DG, and
FM24CL64B-DGTR).
Updated Package Diagrams:
spec 51-85066 – Changed revision from *F to *G.
spec 001-85260 – Changed revision from *A to *B.
Updated to new template.
Document Number: 001-84458 Rev. *K
Page 17 of 19
FM24CL64B
Document History Page (continued)
Document Title: FM24CL64B, 64-Kbit (8K × 8) Serial (I2C) F-RAM
Document Number: 001-84458
Rev.
ECN No.
Orig. of
Change
Submission
Date
Description of Change
*G
4874624
ZSK / PSR
08/06/2015
Updated Maximum Ratings:
Removed “Maximum junction temperature” and its corresponding details.
Added “Maximum accumulated storage time” and its corresponding details.
Added “Ambient temperature with power applied” and its corresponding
details.
*H
5606521
GVCH
01/27/2017
Updated Maximum Ratings:
Updated Electrostatic Discharge Voltage (in compliance with AEC-Q100
standard):
Changed value of “Human Body Model” from 4 kV to 2 kV.
Changed value of “Charged Device Model” from 1.25 kV to 500 V.
Removed “Machine Model” related information.
Updated Package Diagrams:
spec 51-85066 – Changed revision from *G to *H.
Updated to new template.
Completing Sunset Review.
*I
5703890
GVCH
04/20/2017
Updated Maximum Ratings:
Added Note 1 and referred the same note in “Electrostatic Discharge Voltage”.
Updated to new template.
*J
6105573
GVCH
03/21/2018
Updated Package Diagrams:
spec 51-85066 – Changed revision from *H to *I.
Updated to new template.
*K
6306327
GVCH
12/05/2018
Updated Maximum Ratings:
Replaced “–55 °C to +125 °C” with “–65 °C to +125 °C” in ratings corresponding
to “Storage temperature”.
Updated to new template.
Document Number: 001-84458 Rev. *K
Page 18 of 19
FM24CL64B
Sales, Solutions, and Legal Information
Worldwide Sales and Design Support
Cypress maintains a worldwide network of offices, solution centers, manufacturer’s representatives, and distributors. To find the office
closest to you, visit us at Cypress Locations.
PSoC® Solutions
Products
Arm® Cortex® Microcontrollers
Automotive
cypress.com/arm
cypress.com/automotive
Clocks & Buffers
Interface
cypress.com/clocks
cypress.com/interface
Internet of Things
Memory
cypress.com/iot
cypress.com/memory
Microcontrollers
cypress.com/mcu
PSoC
cypress.com/psoc
Power Management ICs
Cypress Developer Community
Community | Projects | Video | Blogs | Training | Components
Technical Support
cypress.com/support
cypress.com/pmic
Touch Sensing
cypress.com/touch
USB Controllers
Wireless Connectivity
PSoC 1 | PSoC 3 | PSoC 4 | PSoC 5LP | PSoC 6 MCU
cypress.com/usb
cypress.com/wireless
© Cypress Semiconductor Corporation, 2013–2018. This document is the property of Cypress Semiconductor Corporation and its subsidiaries, including Spansion LLC (“Cypress”). This document,
including any software or firmware included or referenced in this document (“Software”), is owned by Cypress under the intellectual property laws and treaties of the United States and other countries
worldwide. Cypress reserves all rights under such laws and treaties and does not, except as specifically stated in this paragraph, grant any license under its patents, copyrights, trademarks, or other
intellectual property rights. If the Software is not accompanied by a license agreement and you do not otherwise have a written agreement with Cypress governing the use of the Software, then Cypress
hereby grants you a personal, non-exclusive, nontransferable license (without the right to sublicense) (1) under its copyright rights in the Software (a) for Software provided in source code form, to
modify and reproduce the Software solely for use with Cypress hardware products, only internally within your organization, and (b) to distribute the Software in binary code form externally to end users
(either directly or indirectly through resellers and distributors), solely for use on Cypress hardware product units, and (2) under those claims of Cypress’s patents that are infringed by the Software (as
provided by Cypress, unmodified) to make, use, distribute, and import the Software solely for use with Cypress hardware products. Any other use, reproduction, modification, translation, or compilation
of the Software is prohibited.
TO THE EXTENT PERMITTED BY APPLICABLE LAW, CYPRESS MAKES NO WARRANTY OF ANY KIND, EXPRESS OR IMPLIED, WITH REGARD TO THIS DOCUMENT OR ANY SOFTWARE
OR ACCOMPANYING HARDWARE, INCLUDING, BUT NOT LIMITED TO, THE IMPLIED WARRANTIES OF MERCHANTABILITY AND FITNESS FOR A PARTICULAR PURPOSE. No computing
device can be absolutely secure. Therefore, despite security measures implemented in Cypress hardware or software products, Cypress does not assume any liability arising out of any security breach,
such as unauthorized access to or use of a Cypress product. In addition, the products described in these materials may contain design defects or errors known as errata which may cause the product
to deviate from published specifications. To the extent permitted by applicable law, Cypress reserves the right to make changes to this document without further notice. Cypress does not assume any
liability arising out of the application or use of any product or circuit described in this document. Any information provided in this document, including any sample design information or programming
code, is provided only for reference purposes. It is the responsibility of the user of this document to properly design, program, and test the functionality and safety of any application made of this
information and any resulting product. Cypress products are not designed, intended, or authorized for use as critical components in systems designed or intended for the operation of weapons, weapons
systems, nuclear installations, life-support devices or systems, other medical devices or systems (including resuscitation equipment and surgical implants), pollution control or hazardous substances
management, or other uses where the failure of the device or system could cause personal injury, death, or property damage (“Unintended Uses”). A critical component is any component of a device
or system whose failure to perform can be reasonably expected to cause the failure of the device or system, or to affect its safety or effectiveness. Cypress is not liable, in whole or in part, and you
shall and hereby do release Cypress from any claim, damage, or other liability arising from or related to all Unintended Uses of Cypress products. You shall indemnify and hold Cypress harmless from
and against all claims, costs, damages, and other liabilities, including claims for personal injury or death, arising from or related to any Unintended Uses of Cypress products.
Cypress, the Cypress logo, Spansion, the Spansion logo, and combinations thereof, WICED, PSoC, CapSense, EZ-USB, F-RAM, and Traveo are trademarks or registered trademarks of Cypress in
the United States and other countries. For a more complete list of Cypress trademarks, visit cypress.com. Other names and brands may be claimed as property of their respective owners.
Document Number: 001-84458 Rev. *K
Revised December 5, 2018
Page 19 of 19