S25FL032P
32-Mbit 3.0 V Flash Memory
This product family has been retired and is not recommended for designs. For new and current designs, S25FL064L supersede
S25FL032P. These are the factory-recommended migration paths. Refer to the S25FL-L Family datasheets for specifications and
ordering information.
Distinctive Characteristics
rN
ew
D
es
ig
n
Common Flash Interface (CFI) compliant: allows host system
to identify and accommodate multiple flash devices
Process technology
– Manufactured on 0.09 m MirrorBit® process technology
Package option
– Industry Standard Pinouts
– 8-pin SO package (208 mils)
– 16-pin SO package (300 mils)
– 8-contact USON package (5 6 mm)
– 8-contact WSON package (6 8 mm)
– 24-ball BGA 6 8 mm package, 5 5 pin configuration
– 24-ball BGA 6 8 mm package, 6 4 pin configuration
Performance Characteristics
Speed
– Normal READ (Serial): 40-MHz clock rate
– FAST_READ (Serial): 104-MHz clock rate (maximum)
– DUAL I/O FAST_READ: 80-MHz clock rate or
20 MB/s effective data rate
– QUAD I/O FAST_READ: 80 MHz clock rate or
40 MB/s effective data rate
Power saving standby mode
– Standby Mode 80 A (typical)
– Deep Power-Down Mode 3 A (typical)
N
ot
R
ec
om
m
en
d
ed
Single power supply operation
– Full voltage range: 2.7 V to 3.6 V read and write operations
Memory architecture
– Uniform 64-KB sectors
– Top or bottom parameter block (two 64-KB sectors (top
or bottom) broken down into 16 4-KB sub-sectors each)
– 256-byte page size
– Backward compatible with the S25FL032A device
Program
– Page Program (up to 256 bytes) in 1.5 ms (typical)
– Program operations are on a page by page basis
– Accelerated programming mode via 9-V W#/ACC pin
– Quad Page Programming
Erase
– Bulk erase function
– Sector erase (SE) command (D8h) for 64-KB sectors
– Sub-sector erase (P4E) command (20h) for 4-KB sectors
– Sub-sector erase (P8E) command (40h) for 8-KB sectors
Cycling endurance
– 100,000 cycles per sector typical
Data retention
– 20 years typical
Device ID
– JEDEC standard two-byte electronic signature
– RES command one-byte electronic signature for backward
compatibility
One time programmable (OTP) area for permanent, secure
identification; can be programmed and locked at the factory
or by the customer
fo
Architectural Advantages
Cypress Semiconductor Corporation
Document Number: 002-00650 Rev. *L
•
Memory Protection Features
Memory protection
– W#/ACC pin works in conjunction with Status Register Bits
to protect specified memory areas
– Status Register Block Protection bits (BP2, BP1, BP0) in
status register configure parts of memory as read-only
198 Champion Court
•
San Jose, CA 95134-1709
•
408-943-2600
Revised May 19, 2017
S25FL032P
General Description
The S25FL032P is a 3.0 V (2.7 V to 3.6 V), single-power-supply Flash memory device. The device consists of 64 uniform 64-KB
sectors with the two (top or bottom) 64-KB sectors further split up into thirty-two 4-KB sub sectors. The S25FL032P device is fully
backward compatible with the S25FL032A device.
The device accepts data written to Serial Input (SI) and outputs data on Serial Output (SO). The devices are designed to be
programmed in-system with the standard system 3.0-V VCC supply.
The S25FL032P device adds the following high-performance features using five new instructions:
Dual Output Read using both SI and SO pins as output pins at a clock rate of up to 80 MHz
Quad Output Read using SI, SO, W#/ACC, and HOLD# pins as output pins at a clock rate of up to 80 MHz
Dual I/O High Performance Read using both SI and SO pins as input and output pins at a clock rate of up to 80 MHz
n
Quad I/O High Performance Read using SI, SO, W#/ACC, and HOLD# pins as input and output pins at a clock rate of up to
80 MHz
es
ig
Quad Page Programming using SI, SO, W#/ACC, and HOLD# pins as input pins to program data at a clock rate of up to 80 MHz
D
The memory can be programmed 1 to 256 bytes at a time, using the Page Program command. The device supports Sector Erase
and Bulk Erase commands.
rN
ew
Each device requires only a 3.0-V power supply (2.7 V to 3.6 V) for both read and write functions. Internally generated and regulated
voltages are provided for the program operations. This device requires a high voltage supply to the W#/ACC pin to enable the
Accelerated Programming mode.
N
ot
R
ec
om
m
en
d
ed
fo
The S25FL032P device also offers a One-Time Programmable area (OTP) of up to 128 bits (16 bytes) for permanent secure
identification and an additional 490 bytes of OTP space for other use. This OTP area can be programmed or read using the OTPP or
OTPR instructions.
Document Number: 002-00650 Rev. *L
Page 2 of 60
S25FL032P
Contents
4.
Logic Symbol ............................................................... 7
5.
5.1
Ordering Information ................................................... 8
Valid Combinations ........................................................ 9
6.
SPI Modes................................................................... 10
7.
7.1
7.2
7.3
7.4
7.5
Device Operations .....................................................
Byte or Page Programming..........................................
Quad Page Programming ............................................
Dual and Quad I/O Mode .............................................
Sector Erase / Bulk Erase............................................
Monitoring Write Operations
Using the Status Register ............................................
7.6 Active Power and Standby Power Modes....................
7.7 Status Register ............................................................
7.8 Configuration Register .................................................
7.9 Data Protection Modes ................................................
7.10 Hold Mode (HOLD#) ....................................................
7.11 Accelerated Programming Operation...........................
11
11
11
11
11
11
11
12
12
13
14
15
Sector Address Table ................................................ 16
9.
9.1
9.2
Command Definitions................................................
Read Data Bytes (READ) ............................................
Read Data Bytes at Higher Speed
(FAST_READ) .............................................................
Dual Output Read Mode (DOR)...................................
Quad Output Read Mode (QOR) .................................
DUAL I/O High Performance Read
Mode (DIOR)................................................................
Quad I/O High Performance Read
Mode (QIOR) ...............................................................
Read Identification (RDID) ...........................................
Read-ID (READ_ID).....................................................
Write Enable (WREN) ..................................................
Write Disable (WRDI)...................................................
Read Status Register (RDSR) .....................................
Read Configuration Register (RCR) ............................
Write Registers (WRR) ................................................
Page Program (PP)......................................................
QUAD Page Program (QPP) .......................................
Parameter Sector Erase (P4E, P8E) ...........................
Sector Erase (SE) ........................................................
Bulk Erase (BE) ...........................................................
9.7
9.8
9.9
9.10
9.11
9.12
9.13
9.14
9.15
9.16
9.17
9.18
18
20
en
d
m
ec
om
R
ot
9.6
N
9.3
9.4
9.5
Document Number: 002-00650 Rev. *L
OTP Regions ............................................................... 41
Programming OTP Address Space............................... 41
Reading OTP Data ....................................................... 41
Locking OTP Regions................................................... 42
11.
Power-up and Power-down........................................ 44
12.
Initial Delivery State.................................................... 45
13.
Program Acceleration via W#/ACC Pin..................... 45
14. Electrical Specifications............................................. 46
14.1 Absolute Maximum Ratings .......................................... 46
15.
Operating Ranges ....................................................... 47
16.
DC Characteristics...................................................... 47
17.
Test Conditions ........................................................... 48
18. AC Characteristics...................................................... 49
18.1 Capacitance .................................................................. 50
19. Physical Dimensions .................................................. 52
19.1 SOC008 wide — 8-pin Plastic Small
Outline Package (208-mils Body Width) ....................... 52
19.2 SO3 016 — 16-pin Wide Plastic Small
Outline Package (300-mils Body Width) ....................... 53
19.3 UNE008 — USON 8-contact (5 x 6 mm)
No-Lead Package ......................................................... 54
19.4 WNF008 — WSON 8-contact (6 x 8 mm)
No-Lead Package ......................................................... 55
19.5 FAB024 — 24-ball Ball Grid Array
(6 x 8 mm) Package...................................................... 56
19.6 FAC024 — 24-ball Ball Grid Array
(6 x 8 mm) Package...................................................... 57
ed
8.
10.
10.1
10.2
10.3
n
Input/Output Descriptions........................................... 7
es
ig
3.
D
Connection Diagrams.................................................. 5
Deep Power-Down (DP) ............................................... 38
Release from Deep Power-Down (RES)....................... 39
Clear Status Register (CLSR)....................................... 40
OTP Program (OTPP)................................................... 40
Read OTP Data Bytes (OTPR) ..................................... 40
ew
2.
9.19
9.20
9.21
9.22
9.23
rN
Block Diagram.............................................................. 4
fo
1.
20
21
21
22
23
25
28
29
29
30
31
32
33
35
36
37
37
20. Revision History.......................................................... 58
Document History Page ..................................................... 58
Sales, Solutions, and Legal Information .......................... 60
Worldwide Sales and Design Support ........................... 60
Products ........................................................................ 60
PSoC® Solutions .......................................................... 60
Cypress Developer Community ..................................... 60
Technical Support ......................................................... 60
Page 3 of 60
S25FL032P
1. Block Diagram
SRAM
PS
X
D
E
C
n
Array - R
es
ig
Array - L
rN
ew
D
Logic
RD
W# / ACC / IO2
HOLD# / IO3
VCC
GND
SO / IO1
en
d
SI / IO0
m
SCK
IO
N
ot
R
ec
om
CS#
ed
fo
DATA PATH
Document Number: 002-00650 Rev. *L
Page 4 of 60
S25FL032P
2. Connection Diagrams
Figure 1. 16-pin Plastic Small Outline Package (SO)
1
16
SCK
VCC
2
15
SI/IO0
DNC
3
14
DNC
DNC
4
13
DNC
DNC
5
12
DNC
DNC
6
11
DNC
CS#
7
10
GND
SO/IO1
8
9
es
ig
n
HOLD#/IO3
W#/ACC/IO2
ew
D
Note
DNC = Do Not Connect (Reserved for future use)
2
8
VCC
7
HOLD#/IO3
fo
SO/IO1
ed
1
en
d
CS#
rN
Figure 2. 8-pin Plastic Small Outline Package (SO)
3
6
SCK
GND
4
5
SI/IO0
ec
om
m
W#/ACC/IO2
N
ot
R
Figure 3. 8-contact USON (5 x 6 mm) Package
CS#
1
SO/IO1
2
8
VCC
7
HOLD#/IO3
USON
W#/ACC/IO2
3
6
SCK
GND
4
5
SI/IO0
Note
There is an exposed central pad on the underside of the USON package. This should not be connected to any voltage or signal line on the PCB. Connecting the central
pad to GND (VSS) is possible, provided PCB routing ensures 0mV difference between voltage at the USON GND (VSS) lead and the central exposed pad.
Figure 4. 8-contact WSON Package (6 x 8 mm)
CS#
1
SO/IO1
2
8
VCC
7
HOLD#/IO3
WSON
W#/ACC/IO2
3
6
SCK
GND
4
5
SI/IO0
Note
There is an exposed central pad on the underside of the WSON package. This should not be connected to any voltage or signal line on the PCB. Connecting the central
pad to GND (VSS) is possible, provided PCB routing ensures 0mV difference between voltage at the WSON GND (VSS) lead and the central exposed pad.
Document Number: 002-00650 Rev. *L
Page 5 of 60
S25FL032P
A3
A4
A5
NC
NC
NC
NC
B1
B2
B3
B4
B5
NC
SCK
GND
VCC
NC
C1
C2
C3
C4
C5
NC
CS#
NC W#/ACC/IO2
NC
D1
D2
D3
D5
NC
SO/IO1
E1
E2
E3
E4
E5
NC
NC
NC
NC
NC
D4
NC
rN
ew
D
SI/IO0 HOLD#/IO3
es
ig
A2
n
Figure 5. 6x8 mm 24-ball BGA Package, 5x5 Pin Configuration
A1
ed
fo
Figure 6. 6x8 mm 24-ball BGA Package, 6x4 Pin Configuration
A4
NC
A2
NC
NC
B1
B2
B3
B4
NC
SCK
GND
VCC
C1
C2
C3
C4
NC
CS#
NC W#/ACC/IO2
N
ot
R
ec
om
m
en
d
A3
NC
Document Number: 002-00650 Rev. *L
D1
D2
NC
SO/IO1
D3
D4
E1
E2
E3
E4
NC
NC
NC
NC
F1
F2
F3
F4
NC
NC
NC
NC
SI/IO0 HOLD#/IO3
Page 6 of 60
S25FL032P
3. Input/Output Descriptions
Table 1. Input/Output Descriptions
I/O
Description
SO/IO1
I/O
Serial Data Output: Transfers data serially out of the device on the falling edge of SCK. Functions as an
input pin in Dual and Quad I/O, and Quad Page Program modes.
SI/IO0
I/O
Serial Data Input: Transfers data serially into the device. Device latches commands, addresses, and
program data on SI on the rising edge of SCK. Functions as an output pin in Dual and Quad I/O mode.
SCK
Input
Serial Clock: Provides serial interface timing. Latches commands, addresses, and data on SI on rising
edge of SCK. Triggers output on SO after the falling edge of SCK.
CS#
Input
Chip Select: Places device in active power mode when driven low. Deselects device and places SO at
high impedance when high. After power-up, device requires a falling edge on CS# before any command
is written. Device is in standby mode when a program, erase, or Write Status Register operation is not in
progress.
HOLD#/IO3
I/O
Hold: Pauses any serial communication with the device without deselecting it. When driven low, SO is
at high impedance, and all input at SI and SCK are ignored. Requires that CS# also be driven low.
Functions as an output pin in Quad I/O mode.
W#/ACC/IO2
I/O
Write Protect: Protects the memory area specified by Status Register bits BP2:BP0. When driven low,
prevents any program or erase command from altering the data in the protected memory area. Functions
as an output pin in Quad I/O mode.
VCC
Input
Supply voltage
GND
Input
Ground
ed
fo
rN
ew
D
es
ig
n
Signal
en
d
4. Logic Symbol
m
VCC
ec
om
SI/IO0
SO/IO1
SCK
CS#
HOLD#/IO3
N
ot
R
W#/ACC/IO2
Document Number: 002-00650 Rev. *L
GND
Page 7 of 60
S25FL032P
5.
Ordering Information
The ordering part number is formed by a valid combination of the following:
S25FL
032
P
0X
M
F
I
00
1
Packing Type
0 = Tray
1 = Tube
3 = 13” Tape and Reel
Model Number (Additional Ordering Options)
03 = 6 x 4 pin configuration BGA package
02 = 5 x 5 pin configuration BGA package
01 = 8-pin SO package / 8-contact USON package
00 = 16-pin SO package / 8-contact WSON package
D
Package Materials
F = Lead (Pb)-free
H = Low-Halogen, Lead (Pb)-free
es
ig
n
Temperature Range
I = Industrial (–40°C to +85°C)
V = Automotive In-cabin (–40°C to +105°C)
A = Automotive, AEC-Q100 Grade 3 (–40°C to +85°C)
B = Automotive, AEC-Q100 Grade 2 (–40°C to +105°C)
rN
ew
Package Type
M = 8-pin / 16-pin SO package
N = 8-contact USON / WSON package
B = 24-ball BGA 6 x 8 mm package, 1.00 mm pitch
fo
Speed
0X = 104 MHz
ed
Device Technology
P = 0.09 µm MirrorBit® Process Technology
Device Family
en
d
Density
032 = 32 Mbit
N
ot
R
ec
om
m
S25FL
Cypress Memory 3.0 V-only, Serial Peripheral Interface (SPI) Flash Memory
Document Number: 002-00650 Rev. *L
Page 8 of 60
S25FL032P
5.1
Valid Combinations
Valid Combinations — Standard
Table 2 lists the valid combinations configurations planned to be supported in volume for this device.
Table 2. S25FL032P Valid Combinations
Base Ordering
Part Number
Speed Option
Package and
Temperature
MFI, NFI
S25FL032P
MFV, NFV
0X
Model
Number
Packing Type
00, 01
0, 1, 3
Package Marking
FL032P + (Temp) + F
BHI
02, 03
BHV
0, 3
n
Valid Combinations — Automotive Grade / AEC-Q100
es
ig
Table 3 lists configurations that are Automotive Grade / AEC-Q100 qualified and are planned to be available in volume. The table
will be updated as new combinations are released. Consult your local sales representative to confirm availability of specific
combinations and to check on newly released combinations.
D
Production Part Approval Process (PPAP) support is only provided for AEC-Q100 grade products.
rN
ew
Products to be used in end-use applications that require ISO/TS-16949 compliance must be AEC-Q100 grade products in
combination with PPAP. Non–AEC-Q100 grade products are not manufactured or documented in full compliance with
ISO/TS-16949 requirements.
fo
AEC-Q100 grade products are also offered without PPAP support for end-use applications that do not require ISO/TS-16949
compliance.
Speed Option
Package and
Temperature
en
d
Base Ordering
Part Number
ed
Table 3. S25FL032P Valid Combinations — Automotive Grade / AEC-Q100
0X
MFB, NFB
ec
om
S25FL032P
m
MFA,NFA
Packing Type
00, 01
0, 1, 3
02, 03
0, 3
Package Marking
FL032P + (Temp) + F
N
ot
R
BHA, BHB
Model
Number
Document Number: 002-00650 Rev. *L
Page 9 of 60
S25FL032P
6.
SPI Modes
A microcontroller can use either of its two SPI modes to control Cypress SPI Flash memory devices:
CPOL = 0, CPHA = 0 (Mode 0)
CPOL = 1, CPHA = 1 (Mode 3)
Input data is latched in on the rising edge of SCK, and output data is available from the falling edge of SCK for both modes.
When the bus master is in standby mode, SCK is as shown in Figure 8 for each of the two modes:
SCK remains at 0 for (CPOL = 0, CPHA = 0 Mode 0)
SCK remains at 1 for (CPOL = 1, CPHA = 1 Mode 3)
Figure 7. Bus Master and Memory Devices on the SPI Bus
n
SO
SPI Interface with
(CPOL, CPHA) =
(0, 0) or (1, 1)
es
ig
SI
SCK
SCK SO SI
CS1
ew
fo
CS2
SPI Memory
Device
HOLD#
ed
CS#
CS#
HOLD#
W#/ACC
CS#
HOLD#
W#/ACC
m
en
d
W#/ACC
SPI Memory
Device
rN
SPI Memory
Device
CS3
SCK SO SI
D
SCK SO SI
Bus Master
ec
om
Note
The Write Protect/Accelerated Programming (W#/ACC) and Hold (HOLD#) signals should be driven high (logic level 1) or low (logic level 0) as appropriate.
Figure 8. SPI Modes Supported
R
CS#
Mode 3
0
0
SCK
N
Mode 0
ot
CPOL CPHA
1
1
SCK
SI
SO
Document Number: 002-00650 Rev. *L
MSB
MSB
Page 10 of 60
S25FL032P
7. Device Operations
All Cypress SPI devices accept and output data in bytes (8 bits at a time). The SPI device is a slave device that supports an inactive
clock while CS# is held low.
7.1
Byte or Page Programming
Programming data requires two commands: Write Enable (WREN), which is one byte, and a Page Program (PP) sequence, which
consists of four bytes plus data. The Page Program sequence accepts from 1 byte up to 256 consecutive bytes of data (which is the
size of one page) to be programmed in one operation. Programming means that bits can either be left at 0, or programmed from 1 to
0. Changing bits from 0 to 1 requires an erase operation.
7.2
Quad Page Programming
Dual and Quad I/O Mode
es
ig
7.3
n
The Quad Page Program (QPP) instruction allows up to 256 bytes of data to be programmed using 4 pins as inputs at the same
time, thus effectively quadrupling the data transfer rate, compared to the Page Program (PP) instruction. The Write Enable Latch
(WEL) bit must be set to a 1 using the Write Enable (WREN) command prior to issuing the QPP command.
7.4
rN
ew
D
The S25FL032P device supports Dual and Quad I/O operation when using the Dual/Quad Output Read Mode and the Dual/Quad
I/O High Performance Mode instructions. Using the Dual or Quad I/O instructions allows data to be transferred to or from the device
at two to four times the rate of standard SPI devices. When operating in the Dual or Quad I/O High Performance Mode (BBh or EBh
instructions), data can be read at fast speed using two or four data bits at a time, and the 3-byte address can be input two or four
address bits at a time.
Sector Erase / Bulk Erase
Monitoring Write Operations Using the Status Register
m
7.5
en
d
ed
fo
The Sector Erase (SE) and Bulk Erase (BE) commands set all the bits in a sector or the entire memory array to 1. While bits can be
individually programmed from 1 to 0, erasing bits from 0 to 1 must be done on a sector-wide (SE) or array-wide (BE) level. In addition
to the 64-KB Sector Erase (SE), the S25FL032P device also offers 4-KB Parameter Sector Erase (P4E) and 8-KB Parameter Sector
Erase (P8E).
Active Power and Standby Power Modes
R
7.6
ec
om
The host system can determine when a Write Register, program, or erase operation is complete by monitoring the Write in Progress
(WIP) bit in the Status Register. The Read from Status Register command provides the state of the WIP bit. In addition, the
S25FL032P device offers two additional bits in the Status Register (P_ERR, E_ERR) to indicate whether a Program or Erase
operation was a success or failure.
N
ot
The device is enabled and in the Active Power mode when Chip Select (CS#) is Low. When CS# is high, the device is disabled, but
may still be in the Active Power mode until all program, erase, and Write Registers operations have completed. The device then
goes into the Standby Power mode, and power consumption drops to ISB. The Deep Power-Down (DP) command provides
additional data protection against inadvertent signals. After writing the DP command, the device ignores any further program or
erase commands, and reduces its power consumption to IDP.
Document Number: 002-00650 Rev. *L
Page 11 of 60
S25FL032P
7.7
Status Register
The Status Register contains the status and control bits that can be read or set by specific commands (see Table 10 on page 18).
These bits configure different protection configurations and supply information of operation of the device. (for details see Table 17 on
page 30):
Write In Progress (WIP): Indicates whether the device is performing a Write Registers, program or erase operation.
Write Enable Latch (WEL): Indicates the status of the internal Write Enable Latch.
Block Protect (BP2, BP1, BP0): Nonvolatile bits that define memory area to be software-protected against program and erase
commands.
Erase Error (E_ERR): The Erase Error Bit is used as an Erase operation success and failure check.
Program Error (P_ERR): The Program Error Bit is used as an program operation success and failure check.
7.8
es
ig
n
Status Register Write Disable (SRWD): Places the device in the Hardware Protected mode when this bit is set to 1 and the
W#/ACC input is driven low. In this mode, the non-volatile bits of the Status Register (SRWD, BP2, BP1, BP0) become read-only
bits.
Configuration Register
ew
D
The Configuration Register contains the control bits that can be read or set by specific commands. These bits configure different
configurations and security features of the device.
rN
The FREEZE bit locks the BP2-0 bits in Status Register and the TBPROT and TBPARM bits in the Configuration Register. Note
that once the FREEZE bit has been set to ‘1’, then it cannot be cleared to ‘0’ until a power-on-reset is executed. As long as the
FREEZE bit is set to ‘0’, then the other bits of the Configuration Register, including FREEZE bit, can be written to.
ed
fo
The QUAD bit is nonvolatile and sets the pin out of the device to Quad mode; that is, W#/ACC becomes IO2 and HOLD#
becomes IO3. The instructions for Serial, Dual Output, and Dual I/O reads function as normal. The W#/ACC and HOLD#
functionality does not work when the device is set in Quad mode.
ec
om
m
en
d
The TBPARM bit defines the logical location of the 4 KB parameter sectors. The parameter sectors consist of thirty two 4 KB
sectors. All sectors other than the parameter sectors are defined to be 64-KB uniform in size. When TBPARM is set to a ‘1’, the
4-KB parameter sectors starts at the top of the array. When TBPARM is set to a ‘0’, the 4-KB parameter sectors starts at the
bottom of the array. Note that once this bit is set to a '1', it cannot be changed back to '0'.
R
The BPNV bit defines whether or not the BP2-0 bits in the Status Register are volatile or non-volatile. When BPNV is set to a ‘1’,
the BP2-0 bits in the Status Register are volatile and will be reset to binary 111 after power on reset. When BPNV is set to a ‘0’,
the BP2-0 bits in the Status Register are non-volatile. Note that once this bit is set to a '1', it cannot be changed back to '0'.
N
ot
The TBPROT bit defines the operation of the block protection bits BP2, BP1, and BP0 in the Status Register. When TBPROT is
set to a ‘0’, then the block protection is defined to start from the top of the array. When TBPROT is set to a ‘1’, then the block
protection is defined to start from the bottom of the array. Note that once this bit is set to a '1', it cannot be changed back to '0'.
Note: It is suggested that the Block Protection and Parameter sectors not be set to the same area of the array; otherwise, the user
cannot utilize the Parameter sectors if they are protected. The following matrix shows the recommended settings.
Table 4. Suggested Cross Settings
TBPARM
TBPROT
0
0
Parameter Sectors – Bottom
BP Protection – Top
(default)
0
1
Not recommended (Parameters & BP Protection are both Bottom)
1
0
Not recommended (parameters & BP Protection are both Top)
1
1
Parameter Sectors - Top of Array (high address)
BP Protection - Bottom of Array (low address)
Document Number: 002-00650 Rev. *L
Array Overview
Page 12 of 60
S25FL032P
Table 5. Configuration Register Table
Bit
Bit Name
Bit Function
7
NA
Description
Not Used
6
NA
Not Used
5
TBPROT
4
NA
3
BPNV
2
TBPARM
1
QUAD
0
FREEZE
1 = Bottom Array (low address)
0 = Top Array (high address) (Default)
Configures start of block protection
Do not use
1 = Volatile
0 = Nonvolatile (Default)
Configures Parameter sector location
1 = Top Array (high address)
0 = Bottom Array (low address) (Default)
Puts the device into Quad I/O mode
1 = Quad I/O
0 = Dual or Serial I/O (Default)
es
ig
n
Configures BP2-0 bits in the Status Register
1 = Enabled
0 = Disabled (Default)
7.9
rN
Note
(Default) indicates the value of each Configuration Register bit set upon initial factory shipment.
ew
D
Locks BP2-0 bits in the Status Register
Data Protection Modes
fo
Cypress SPI Flash memory devices provide the following data protection methods:
en
d
ed
The Write Enable (WREN) command: Must be written prior to any command that modifies data. The WREN command sets the
Write Enable Latch (WEL) bit. The WEL bit resets (disables writes) on power-up or after the device completes the following
commands:
m
– Page Program (PP)
ec
om
– Sector Erase (SE)
– Bulk Erase (BE)
– Write Register (WRR)
R
– Write Disable (WRDI)
ot
– Parameter 4 KB Sector Erase (P4E)
N
– Parameter 8 KB Sector Erase (P8E)
– Quad Page Programming (QPP)
– OTP Byte Programming (OTPP)
Software Protected Mode (SPM): The Block Protect (BP2, BP1, BP0) bits define the section of the memory array that can be
read but not programmed or erased. Table 6 and Table 7 shows the sizes and address ranges of protected areas that are defined
by Status Register bits BP2:BP0.
Hardware Protected Mode (HPM): The Write Protect (W#/ACC) input and the Status Register Write Disable (SRWD) bit together
provide write protection.
Clock Pulse Count: The device verifies that all program, erase, and Write Register commands consist of a clock pulse count that
is a multiple of eight before executing them.
Document Number: 002-00650 Rev. *L
Page 13 of 60
S25FL032P
Table 6. TBPROT = 0 (Starts Protection from TOP of Array)
Status Register Block
Memory Array
Protected
Address Range
Protected
Sectors
Unprotected
Address Range
Unprotected
Sectors
Protected
Portion of
Total Memory
Area
BP1
BP0
0
0
0
None
0
000000h-3FFFFFh
SA63:SA0
0
0
0
1
3F0000h-3FFFFFh
(1) SA63
000000h-3EFFFFh
SA62:SA0
1/64
0
1
0
3E0000h-3FFFFFh
(2) SA63:SA62
000000h-3DFFFFh
SA61:SA0
1/32
0
1
1
3C0000h-3FFFFFh
(4) SA63:SA60
000000h-3BFFFFh
SA59:SA0
1/16
1
0
0
380000h-3FFFFFh
(8) SA63:SA56
000000h-37FFFFh
SA55:SA0
1/8
1
0
1
300000h-3FFFFFh
(16) SA63:SA48
000000h-2FFFFFh
SA47:SA0
1/4
1
1
0
200000h-3FFFFFh
(32) SA63:SA32
000000h-1FFFFFh
SA31:SA0
1/2
1
1
1
000000h-3FFFFFh
(64) SA63:SA0
None
None
All
Unprotected
Sectors
Protected
Portion of
Total Memory
Area
BP0
Protected
Address Range
Protected
Sectors
0
0
None
0
0
0
1
000000h-00FFFFh
(1) SA0
0
1
0
000000h-01FFFFh
(2) SA0:SA1
0
1
1
000000h-03FFFFh
(4) SA0:SA3
1
0
0
000000h-07FFFFh
1
0
1
000000h-0FFFFFh
1
1
0
000000h-1FFFFFh
1
1
1
000000h-3FFFFFh
SA0:SA63
0
010000h-3FFFFFh
SA1:SA63
1/64
020000h-3FFFFFh
SA2:SA63
1/32
040000h-3FFFFFh
SA4:SA63
1/16
ed
(8) SA0:SA7
SA8:SA63
1/8
100000h-3FFFFFh
SA16:SA63
1/4
(32) SA0:SA31
200000h-3FFFFFh
SA32:SA63
1/2
None
None
ALL
m
en
d
080000h-3FFFFFh
(16) SA0:SA15
(64) SA0:SA63
ec
om
7.10
000000h-3FFFFFh
fo
0
Unprotected
Address Range
ew
BP1
rN
BP2
Memory Array
D
Status Register Block
es
ig
Table 7. TBPROT=1 (Starts Protection from BOTTOM of Array)
n
BP2
Hold Mode (HOLD#)
R
The Hold input (HOLD#) stops any serial communication with the device, but does not terminate any Write Registers, program or
erase operation that is currently in progress.
N
ot
The Hold mode starts on the falling edge of HOLD# if SCK is also low (see Figure 9, standard use). If the falling edge of HOLD#
does not occur while SCK is low, the Hold mode begins after the next falling edge of SCK (non-standard use).
The Hold mode ends on the rising edge of HOLD# signal (standard use) if SCK is also low. If the rising edge of HOLD# does not
occur while SCK is low, the Hold mode ends on the next falling edge of CLK (non-standard use) See Figure 9.
The SO output is high impedance, and the SI and SCK inputs are ignored (don’t care) for the duration of the Hold mode.
CS# must remain low for the entire duration of the Hold mode to ensure that the device internal logic remains unchanged. If CS#
goes high while the device is in the Hold mode, the internal logic is reset. To prevent the device from reverting to the Hold mode
when device communication is resumed, HOLD# must be held high, followed by driving CS# low.
Note: The HOLD Mode feature is disabled during Quad I/O Mode.
Document Number: 002-00650 Rev. *L
Page 14 of 60
S25FL032P
Figure 9. Hold Mode Operation
SCK
HOLD#
Hold
Condition
(standard use)
7.11
Hold
Condition
(non-standard use)
Accelerated Programming Operation
D
es
ig
n
The device offers accelerated program operations through the ACC function. This function is primarily intended to allow faster
manufacturing throughput at the factory. If the system asserts VHH on this pin, the device uses the higher voltage on the pin to
reduce the time required for program operations. Removing VHH from the W#/ACC pin returns the device to normal operation. Note
that the W#/ACC pin must not be at VHH for operations other than accelerated programming, or device damage may result. In
addition, the W#/ACC pin must not be left floating or unconnected; inconsistent behavior of the device may result.
N
ot
R
ec
om
m
en
d
ed
fo
rN
ew
Note: The ACC function is disabled during Quad I/O Mode.
Document Number: 002-00650 Rev. *L
Page 15 of 60
S25FL032P
8. Sector Address Table
The Sector Address tables show the size of the memory array, sectors, and pages. The device uses pages to cache the program
data before the data is programmed into the memory array. Each page or byte can be individually programmed (bits are changed
from 1 to 0). The data is erased (bits are changed from 0 to 1) on a sub-sector, sector- or device-wide basis using the P4E/P8E, SE
or BE commands. Table 8 and Table 9 show the starting and ending address for each sector. The complete set of sectors comprises
the memory array of the Flash device.
Table 8. S25FL032P Sector Address Table TBPARM=0
Sector
Address range
Start address
End address
Address range
Sector
Start address
End address
Sector
Address range
Start address
End address
3F0000h
3FFFFFh
SA31
1F0000h
1FFFFFh
SS31
01F000h
01FFFFh
SA62
3E0000h
3EFFFFh
SA30
1E0000h
1EFFFFh
SS30
01E000h
01EFFFh
SA61
3D0000h
3DFFFFh
SA29
1D0000h
1DFFFFh
SS29
01D000h
01DFFFh
SA60
3C0000h
3CFFFFh
SA28
1C0000h
1CFFFFh
SS28
01C000h
01CFFFh
SA59
3B0000h
3BFFFFh
SA27
1B0000h
1BFFFFh
SS27
01B000h
01BFFFh
SA58
3A0000h
3AFFFFh
SA26
1A0000h
1AFFFFh
SS26
01A000h
01AFFFh
SA57
390000h
39FFFFh
SA25
190000h
19FFFFh
SS25
019000h
019FFFh
SA56
380000h
38FFFFh
SA24
180000h
18FFFFh
SS24
018000h
018FFFh
SA55
370000h
37FFFFh
SA23
170000h
17FFFFh
SS23
017000h
017FFFh
SA54
360000h
36FFFFh
SA22
160000h
16FFFFh
SS22
016000h
016FFFh
SA53
350000h
35FFFFh
SA21
150000h
15FFFFh
SS21
015000h
015FFFh
SA52
340000h
34FFFFh
SA20
140000h
14FFFFh
SS20
014000h
014FFFh
SA51
330000h
33FFFFh
SA19
130000h
13FFFFh
SS19
013000h
013FFFh
SA50
320000h
32FFFFh
SA18
120000h
12FFFFh
SS18
012000h
012FFFh
SA49
310000h
31FFFFh
SA17
110000h
11FFFFh
SS17
011000h
011FFFh
SA48
300000h
30FFFFh
SA16
100000h
10FFFFh
SS16
010000h
010FFFh
es
ig
D
ew
rN
fo
ed
en
d
m
n
SA63
SA47
2F0000h
2FFFFFh
0F0000h
0FFFFFh
SS15
00F000h
00FFFFh
SA46
2E0000h
2EFFFFh
SA14
0E0000h
0EFFFFh
SS14
00E000h
00EFFFh
SA45
2D0000h
2DFFFFh
SA13
0D0000h
0DFFFFh
SS13
00D000h
00DFFFh
SA44
2C0000h
2CFFFFh
SA12
0C0000h
0CFFFFh
SS12
00C000h
00CFFFh
SA43
2B0000h
2BFFFFh
SA11
0B0000h
0BFFFFh
SS11
00B000h
00BFFFh
SA42
2A0000h
2AFFFFh
SA10
0A0000h
0AFFFFh
SS10
00A000h
00AFFFh
SA41
290000h
29FFFFh
SA9
090000h
09FFFFh
SS9
009000h
009FFFh
SA40
280000h
28FFFFh
SA8
080000h
08FFFFh
SS8
008000h
008FFFh
SA39
270000h
27FFFFh
SA7
070000h
07FFFFh
SS7
007000h
007FFFh
SA38
260000h
26FFFFh
SA6
060000h
06FFFFh
SS6
006000h
006FFFh
SA37
250000h
25FFFFh
SA5
050000h
05FFFFh
SS5
005000h
005FFFh
SA36
240000h
24FFFFh
SA4
040000h
04FFFFh
SS4
004000h
004FFFh
SA35
230000h
23FFFFh
SA3
030000h
03FFFFh
SS3
003000h
003FFFh
SA34
220000h
22FFFFh
SA2
020000h
02FFFFh
SS2
002000h
002FFFh
SA33
210000h
21FFFFh
SA1
010000h
01FFFFh
SS1
001000h
001FFFh
SA32
200000h
20FFFFh
SA0
000000h
00FFFFh
SS0
000000h
000FFFh
N
ot
R
ec
om
SA15
Note
Sector SA0 is split up into sub-sectors SS0 - SS15 (dark gray shading).
Sector SA1 is split up into sub-sectors SS16 - SS31(light gray shading).
Document Number: 002-00650 Rev. *L
Page 16 of 60
S25FL032P
Table 9. S25FL032P Sector Address Table TBPARM=1
Sector
SS31
Address Range
Address Range
Sector
Start Address
End Address
3FF000h
3FFFFFh
SA63
Start Address
End Address
3F0000h
3FFFFFh
Sector
Address Range
Start Address
End Address
1F0000h
1FFFFFh
SA31
3FE000h
3FEFFFh
SA62
3E0000h
3EFFFFh
SA30
1E0000h
1EFFFFh
SS29
3FD000h
3FDFFFh
SA61
3D0000h
3DFFFFh
SA29
1D0000h
1DFFFFh
SS28
3FC000h
3FCFFFh
SA60
3C0000h
3CFFFFh
SA28
1C0000h
1CFFFFh
SS27
3FB000h
3FBFFFh
SA59
3B0000h
3BFFFFh
SA27
1B0000h
1BFFFFh
SS26
3FA000h
3FAFFFh
SA58
3A0000h
3AFFFFh
SA26
1A0000h
1AFFFFh
SS25
3F9000h
3F9FFFh
SA57
390000h
39FFFFh
SA25
190000h
19FFFFh
SS24
3F8000h
3F8FFFh
SA56
380000h
38FFFFh
SA24
180000h
18FFFFh
SS23
3F7000h
3F7FFFh
SA55
370000h
37FFFFh
SA23
170000h
17FFFFh
SS22
3F6000h
3F6FFFh
SA54
360000h
36FFFFh
SA22
SS21
3F5000h
3F5FFFh
SA53
350000h
35FFFFh
SS20
3F4000h
3F4FFFh
SA52
340000h
34FFFFh
SS19
3F3000h
3F3FFFh
SA51
330000h
33FFFFh
SS18
3F2000h
3F2FFFh
SA50
320000h
SS17
3F1000h
3F1FFFh
SA49
310000h
SS16
3F0000h
3F0FFFh
SA48
300000h
SS15
3EF000h
3EFFFFh
SA47
2F0000h
n
SS30
16FFFFh
150000h
15FFFFh
SA20
140000h
14FFFFh
SA19
130000h
13FFFFh
32FFFFh
SA18
120000h
12FFFFh
31FFFFh
SA17
110000h
11FFFFh
30FFFFh
SA16
100000h
10FFFFh
2FFFFFh
SA15
0F0000h
0FFFFFh
fo
rN
ew
D
es
ig
160000h
SA21
3EE000h
3EEFFFh
SA46
2E0000h
2EFFFFh
SA14
0E0000h
0EFFFFh
SS13
3ED000h
3EDFFFh
SA45
2D0000h
2DFFFFh
SA13
0D0000h
0DFFFFh
SS12
3EC000h
3ECFFFh
SA44
2C0000h
SS11
3EB000h
3EBFFFh
SA43
SS10
3EA000h
3EAFFFh
SA42
SS9
3E9000h
3E9FFFh
SA41
SS8
3E8000h
3E8FFFh
SS7
3E7000h
SS6
SS5
ed
SS14
SA12
0C0000h
0CFFFFh
2BFFFFh
SA11
0B0000h
0BFFFFh
2A0000h
2AFFFFh
SA10
0A0000h
0AFFFFh
290000h
29FFFFh
SA9
090000h
09FFFFh
SA40
280000h
28FFFFh
SA8
080000h
08FFFFh
3E7FFFh
SA39
270000h
27FFFFh
SA7
070000h
07FFFFh
3E6000h
3E6FFFh
SA38
260000h
26FFFFh
SA6
060000h
06FFFFh
3E5000h
3E5FFFh
SA37
250000h
25FFFFh
SA5
050000h
05FFFFh
SS4
3E4000h
3E4FFFh
SA36
240000h
24FFFFh
SA4
040000h
04FFFFh
SS3
3E3000h
3E3FFFh
SA35
230000h
23FFFFh
SA3
030000h
03FFFFh
SS2
3E2000h
3E2FFFh
SA34
220000h
22FFFFh
SA2
020000h
02FFFFh
SS1
3E1000h
3E1FFFh
SA33
210000h
21FFFFh
SA1
010000h
01FFFFh
SS0
3E0000h
3E0FFFh
SA32
200000h
20FFFFh
SA0
000000h
00FFFFh
N
ot
R
ec
om
m
en
d
2CFFFFh
2B0000h
Note
Sector SA62 is split up into sub-sectors SS0 - SS15 (dark gray shading).
Sector SA63 is split up into sub-sectors SS16 - SS31 (light gray shading).
Document Number: 002-00650 Rev. *L
Page 17 of 60
S25FL032P
9.
Command Definitions
The host system must shift all commands, addresses, and data in and out of the device, beginning with the most significant bit. On
the first rising edge of SCK after CS# is driven low, the device accepts the one-byte command on SI (all commands are one byte
long), most significant bit first. Each successive bit is latched on the rising edge of SCK. Table 10 lists the complete set of
commands.
Every command sequence begins with a one-byte command code. The command may be followed by address, data, both, or
nothing, depending on the command. CS# must be driven high after the last bit of the command sequence has been written.
The Read Data Bytes (READ), Read Data Bytes at Higher Speed (FAST_READ), Dual Output Read (DOR), Quad Output Read
(QOR), Dual I/O High Performance Read (DIOR), Quad I/O High Performance Read (QIOR), Read Status Register (RDSR), Read
Configuration Register (RCR), Read OTP Data (OTPR), Read Manufacturer and Device ID (READ_ID), Read Identification (RDID)
and Release from Deep Power-Down and Read Electronic Signature (RES) command sequences are followed by a data output
sequence on SO. CS# can be driven high after any bit of the sequence is output to terminate the operation.
D
es
ig
n
The Page Program (PP), Quad Page Program (QPP), 64 KB Sector Erase (SE), 4 KB Parameter Sector Erase (P4E), 8 KB
Parameter Sector Erase (P8E), Bulk Erase (BE), Write Status and Configuration Registers (WRR), Program OTP space (OTPP),
Write Enable (WREN), or Write Disable (WRDI) commands require that CS# be driven high at a byte boundary, otherwise the
command is not executed. Since a byte is composed of eight bits, CS# must therefore be driven high when the number of clock
pulses after CS# is driven low is an exact multiple of eight.
ew
The device ignores any attempt to access the memory array during a Write Registers, program, or erase operation, and continues
the operation uninterrupted. The instruction set is listed in Table 10.
READ
One Byte
Command Code
Description
fo
Command
ed
Operation
rN
Table 10. Instruction Set
(03h) 0000 0011 Read Data bytes
Erase
Program
Dummy
Byte
Cycle
Data
Byte
Cycle
3
0
0
1 to
3
0
1
1 to
(3Bh) 0011 1011 Dual Output Read
3
0
1
1 to
QOR
(6Bh) 0110 1011 Quad Output Read
3
0
1
1 to
DIOR
(BBh) 1011 1011 Dual I/O High Performance Read
3
1
0
1 to
QIOR
(EBh) 1110 1011 Quad I/O High Performance Read
3
1
2
1 to
RDID
(9Fh) 1001 1111 Read Identification
0
0
0
1 to 81
3
0
0
1 to
(06h) 0000 0110 Write Enable
0
0
0
0
(04h) 0000 0100 Write Disable
0
0
0
0
P4E
(20h) 0010 0000 4-KB Parameter Sector Erase
3
0
0
0
P8E
(40h) 0100 0000
3
0
0
0
SE
(D8h) 1101 1000 64-KB Sector Erase
3
0
0
0
BE
(60h) 0110 0000
or (C7h) 1100 Bulk Erase
0111
0
0
0
0
PP
(02h) 0000 0010 Page Programming
3
0
0
1 to 256
(32h) 0011 0010 Quad Page Programming
3
0
0
1 to 256
WRDI
QPP
en
d
m
ec
om
R
ot
WREN
(90h) 1001 0000
Read Manufacturer and Device
Identification
N
READ_ID
Write Control
Mode
Bit
Cycle
DOR
FAST_READ (0Bh) 0000 1011 Read Data bytes at Fast Speed
Read
Address
Byte Cycle
Document Number: 002-00650 Rev. *L
8-KB (two 4KB) Parameter Sector
Erase
Page 18 of 60
S25FL032P
Table 10. Instruction Set (Continued)
Address
Byte Cycle
Mode
Bit
Cycle
Dummy
Byte
Cycle
Data
Byte
Cycle
0
0
0
1 to
WRR
(01h) 0000 0001 Write (Status & Configuration) Register
0
0
0
1 to 2
RCR
(35h) 0011 0101 Read Configuration Register (CFG)
0
0
0
1 to
CLSR
Reset the Erase and Program Fail Flag
(30h) 0011 0000 (SR5 and SR6) and restore normal
operation)
0
0
0
0
(B9h) 1011 1001 Deep Power-Down
0
0
0
0
(ABh) 1010 1011 Release from Deep Power-Down Mode
0
0
0
0
Release from Deep Power-Down and
(ABh) 1010 1011
Read Electronic Signature
0
0
3
1 to
3
0
0
1
3
0
1
1 to
RES
Program one byte of data in OTP
memory space
n
(05h) 0000 0101 Read Status Register
OTPP
(42h) 0100 0010
OTPR
(4Bh) 0100 1011 Read data in the OTP memory space
N
ot
R
ec
om
m
en
d
ed
fo
rN
ew
OTP
Description
RDSR
DP
Power
Saving
One Byte
Command Code
es
ig
Status &
Configuration
Register
Command
D
Operation
Document Number: 002-00650 Rev. *L
Page 19 of 60
S25FL032P
9.1
Read Data Bytes (READ)
The Read Data Bytes (READ) command reads data from the memory array at the frequency (fR) presented at the SCK input, with a
maximum speed of 40 MHz. The host system must first select the device by driving CS# low. The READ command is then written to
SI, followed by a 3 byte address (A23-A0). Each bit is latched on the rising edge of SCK. The memory array data, at that address,
are output serially on SO at a frequency fR, on the falling edge of SCK.
Figure 10 and Table 10 on page 18 detail the READ command sequence. The first address byte specified can start at any location
of the memory array. The device automatically increments to the next higher address after each byte of data is output. The entire
memory array can therefore be read with a single READ command. When the highest address is reached, the address counter
reverts to 00000h, allowing the read sequence to continue indefinitely.
The READ command is terminated by driving CS# high at any time during data output. The device rejects any READ command
issued while it is executing a program, erase, or Write Registers operation, and continues the operation uninterrupted.
n
Figure 10. Read Data Bytes (READ) Command Sequence
0
2 3
4
5
6
7
8
28 29 30 31 32 33 34 35 36 37 38 39
9 10
Command
24 Bit Address
3 2 1 0
fo
23 22 21
SI
Hi-Z
Data Out 2
en
d
7 6 5 4 3 2
1 0 7
MSB
Read Data Bytes at Higher Speed (FAST_READ)
m
9.2
Data Out 1
ed
MSB
SO
ew
Mode 0
rN
SCK
1
D
Mode 3
es
ig
CS#
R
ec
om
The FAST_READ command reads data from the memory array at the frequency (fC) presented at the SCK input, with a maximum
speed of 104 MHz. The host system must first select the device by driving CS# low. The FAST_READ command is then written to
SI, followed by a 3 byte address (A23-A0) and a dummy byte. Each bit is latched on the rising edge of SCK. The memory array data,
at that address, are output serially on SO at a frequency fC, on the falling edge of SCK.
N
ot
The FAST_READ command sequence is shown in Figure 11 and Table 10 on page 18. The first address byte specified can start at
any location of the memory array. The device automatically increments to the next higher address after each byte of data is output.
The entire memory array can therefore be read with a single FAST_READ command. When the highest address is reached, the
address counter reverts to 000000h, allowing the read sequence to continue indefinitely.
The FAST_READ command is terminated by driving CS# high at any time during data output. The device rejects any FAST_READ
command issued while it is executing a program, erase, or Write Registers operation, and continues the operation uninterrupted.
Figure 11. Read Data Bytes at Higher Speed (FAST_READ) Command Sequence
CS#
Mode 3
SCK
0
1
2
3
4
5
Command
7
8
9
10
28 29 30
31 32 33
24 Bit Address
23 22 21
SI
SO
6
34 35 36 37 38
39
40 41
42 43 44 45
46
47
Mode 0
Hi-Z
3
2
Dummy Byte
1
0
7
6
5
4
3
2
1
0
7
MSB
Document Number: 002-00650 Rev. *L
6
5
4
3
DATA OUT 1
2
1
0
7
MSB
DATA OUT 2
Page 20 of 60
S25FL032P
9.3
Dual Output Read Mode (DOR)
The Dual Output Read instruction is similar to the FAST_READ instruction, except that the data is shifted out 2 bits at a time using 2
pins (SI/IO0 and SO/IO1) instead of 1 bit, at a maximum frequency of 80 MHz. The Dual Output Read mode effectively doubles the
data transfer rate compared to the FAST_READ instruction.
The host system must first select the device by driving CS# low. The Dual Output Read command is then written to SI, followed by a
3-byte address (A23-A0) and a dummy byte. Each bit is latched on the rising edge of SCK. Then the memory contents, at the
address that is given, are shifted out two bits at a time through the IO0 (SI) and IO1 (SO) pins at a frequency fC on the falling edge of
SCK.
The Dual Output Read command sequence is shown in Figure 12 and Table 10 on page 18. The first address byte specified can
start at any location of the memory array. The device automatically increments to the next higher address after each byte of data is
output. The entire memory array can therefore be read with a single Dual Output Read command. When the highest address is
reached, the address counter reverts to 00000h, allowing the read sequence to continue indefinitely.
n
It is important that the I/O pins be set to high-impedance prior to the falling edge of the first data out clock.
D
es
ig
The Dual Output Read command is terminated by driving CS# high at any time during data output. The device rejects any Dual
Output Read command issued while it is executing a program, erase, or Write Registers operation, and continues the operation
uninterrupted.
ew
Figure 12. Dual Output Read Instruction Sequence
CS#
1
2
3
5
4
6
7
8
9 10
28 29 30 31 32 33 34 35 36 37 38 39 40 41 42 43 44 45 46 47
rN
0
SCK
Hi-Z
2
1
0
7
6
5
4
3
2
SI Switches from Input to Output
1
0
6
4
2
0
6
4
2
0
6
7
5
3
1
7
5
3
1
7
*
*
Byte 1
*
Byte 2
m
SO/IO1
*MSB
Quad Output Read Mode (QOR)
ec
om
9.4
3
en
d
23 22 21
*
Dummy Byte
ed
SI/IO0
fo
24 Bit
Address
Instruction
ot
R
The Quad Output Read instruction is similar to the FAST_READ instruction, except that the data is shifted out 4 bits at a time using
4 pins (SI/IO0, SO/IO1, W#/ACC/IO2 and HOLD#/IO3) instead of 1 bit, at a maximum frequency of 80 MHz. The Quad Output Read
mode effectively doubles the data transfer rate compared to the Dual Output Read instruction, and is four times the data transfer rate
of the FAST_READ instruction.
N
The host system must first select the device by driving CS# low. The Quad Output Read command is then written to SI, followed by
a 3-byte address (A23-A0) and a dummy byte. Each bit is latched on the rising edge of SCK. Then the memory contents, at the
address that are given, are shifted out four bits at a time through IO0 (SI), IO1 (SO), IO2 (W#/ACC), and IO3 (HOLD#) pins at a
frequency fC on the falling edge of SCK.
The Quad Output Read command sequence is shown in Figure 13 and Table 10 on page 18. The first address byte specified can
start at any location of the memory array. The device automatically increments to the next higher address after each byte of data is
output. The entire memory array can therefore be read with a single Quad Output Read command. When the highest address is
reached, the address counter reverts to 00000h, allowing the read sequence to continue indefinitely.
It is important that the I/O pins be set to high-impedance prior to the falling edge of the first data out clock.
The Quad Output Read command is terminated by driving CS# high at any time during data output. The device rejects any Quad
Output Read command issued while it is executing a program, erase, or Write Registers operation, and continues the operation
uninterrupted.
The Quad bit of Configuration Register must be set (CR Bit1 = 1) to enable the Quad mode capability of the S25FL device.
Document Number: 002-00650 Rev. *L
Page 21 of 60
S25FL032P
Figure 13. Quad Output Read Instruction Sequence
CS#
0
1
2
3
4
5
6
7
8
9 10
28 29 30 31 32 33 34 35 36 37 38 39 40 41 42 43 44 45 46 47
SCK
24 Bit
Address
Instruction
SI/IO0
Hi-Z
SO/IO1
23 22 21
*
3 2 1
Dummy Byte
0
7 6 5
4 3
SI Switches from Input to Output
2 1 0
*
Hi-Z
W#/ACC/IO2
Hi-Z
HOLD#/IO3
4 0
4 0
4 0
4 0
4
5
1
5
1
5
5
1 5
6
2
6
2 6
2
6
2
6
7
3
7
3 7
3
7
3
7
1
9.5
DUAL I/O High Performance Read Mode (DIOR)
es
ig
n
*
*
*
*
*
DATA DATA DATA DATA
OUT 1 OUT 2 OUT 3 OUT 4
*MSB
ew
D
The Dual I/O High Performance Read instruction is similar to the Dual Output Read instruction, except that it improves throughput by
allowing input of the address bits (A23-A0) using 2 bits per SCK via two input pins (SI/IO2 and SO/IO1), at a maximum frequency of
80 MHz.
fo
rN
The host system must first select the device by driving CS# low. The Dual I/O High Performance Read command is then written to
SI, followed by a 3-byte address (A23-A0) and a 1-byte Mode instruction, with two bits latched on the rising edge of SCK. Then the
memory contents, at the address that is given, are shifted out two bits at a time through IO0 (SI) and IO1 (SO).
en
d
ed
The DUAL I/O High Performance Read command sequence is shown in Figure 14 and Table 10 on page 18. The first address byte
specified can start at any location of the memory array. The device automatically increments to the next higher address after each
byte of data is output. The entire memory array can therefore be read with a single DUAL I/O High Performance Read command.
When the highest address is reached, the address counter reverts to 00000h, allowing the read sequence to continue indefinitely.
N
ot
R
ec
om
m
In addition, address jumps can be done without exiting the Dual I/O High Performance Mode through the setting of the Mode bits
(after the Address (A23-0) sequence, as shown in Figure 14). This added feature removes the need for the instruction sequence and
greatly improves code execution (XIP). The upper nibble (bits 7-4) of the Mode bits control the length of the next Dual I/O High
Performance instruction through the inclusion or exclusion of the first byte instruction code. The lower nibble (bits 3-0) of the Mode
bits are DON’T CARE (“x”). If the Mode bits equal Axh, then the device remains in Dual I/O High Performance Read Mode and the
next address can be entered (after CS# is raised high and then asserted low) without requiring the BBh instruction opcode, as
shown in Figure 15, thus eliminating eight cycles for the instruction sequence. However, if the Mode bits are any value other than
Axh, then the next instruction (after CS# is raised high and then asserted low) requires the instruction sequence, which is normal
operation. The following sequences will release the device from Dual I/O High Performance Read mode; after which, the device can
accept standard SPI instructions:
1. During the Dual I/O High Performance Instruction Sequence, if the Mode bits are any value other than Axh, then the next
time CS# is raised high and then asserted low, the device will be released from Dual I/O High Performance Read mode.
2. Furthermore, during any operation, if CS# toggles high to low to high for eight cycles (or less) and data input (IO0 and
IO1) are not set for a valid instruction sequence, then the device will be released from Dual I/O High Performance Read
mode.
It is important that the I/O pins be set to high-impedance prior to the falling edge of the first data out clock.
The read instruction can be terminated by driving the CS# pin to the logic high state. The CS# pin can be driven high at any time
during data output to terminate a read operation.
Document Number: 002-00650 Rev. *L
Page 22 of 60
S25FL032P
Figure 14. DUAL I/O High Performance Read Instruction Sequence
CS#
0
1
2
3
4
5
6
7
8
9
10
18
19
20
21
22
23
24
25
26
27
28
29
30
31
SCK
24 Bit
Address
Instruction
SI/IO0
IO0 & IO1 Switches from Input to Output
22 20
2
0
6
4
2
0
6
4
2
0
6
4
2
0
6
23 21
*
3
1
7
5
3
1
7
5
3
1
7
5
3
1
7
Hi-Z
SO/IO1
*
*
*
*
Byte 1
Byte 2
*MSB
n
Mode Bits
es
ig
Figure 15. Continuous Dual I/O High Performance Read Instruction Sequence
D
CS#
1
9
10
11
12
13
14
15
16
17
24 Bit
Address
0
6
4
23
3
1
7
5
21
2
3
*
21
22
23
0
6
1
7
4
2
0
6
4
2
0
6
5
3
1
7
5
3
1
7
*
*
Byte 1
*
Byte 2
*MSB
m
Mode Bits
Quad I/O High Performance Read Mode (QIOR)
ec
om
9.6
fo
2
ed
22 20
*
20
IO0 & IO1 Switches from Input to Output
en
d
SO/IO1
19
rN
SCK
SI/IO0
18
ew
0
R
The Quad I/O High Performance Read instruction is similar to the Quad Output Read instruction, except that it further improves
throughput by allowing input of the address bits (A23-A0) using 4 bits per SCK via four input pins (SI/IO0, SO/IO1, W#/ACC/IO2, and
HOLD#/IO3), at a maximum frequency of 80 MHz.
N
ot
The host system must first select the device by driving CS# low. The Quad I/O High Performance Read command is then written to
SI, followed by a 3-byte address (A23-A0) and a 1-byte Mode instruction, with four bits latched on the rising edge of SCK. Note that
four dummy clocks are required prior to the data input. Then the memory contents, at the address that is given, are shifted out four
bits at a time through IO0 (SI), IO1 (SO), IO2 (W#/ACC), and IO3 (HOLD#).
The Quad I/O High Performance Read command sequence is shown in Figure 16 and Table 10 on page 18. The first address byte
specified can start at any location of the memory array. The device automatically increments to the next higher address after each
byte of data is output. The entire memory array can therefore be read with a single Quad I/O High Performance Read command.
When the highest address is reached, the address counter reverts to 00000h, allowing the read sequence to continue indefinitely.
In addition, address jumps can be done without exiting the Quad I/O High Performance Mode through the setting of the Mode bits
(after the Address (A23-0) sequence, as shown in Figure 16). This added feature the removes the need for the instruction sequence
and greatly improves code execution (XIP). The upper nibble (bits 7-4) of the Mode bits control the length of the next Quad I/O High
Performance instruction through the inclusion or exclusion of the first byte instruction code. The lower nibble (bits 3-0) of the Mode
bits are DON'T CARE (“x”). If the Mode bits equal Axh, then the device remains in Quad I/O High Performance Read Mode and the
next address can be entered (after CS# is raised high and then asserted low) without requiring the EBh instruction opcode, as
shown in Figure 17, thus eliminating eight cycles for the instruction sequence.
Document Number: 002-00650 Rev. *L
Page 23 of 60
S25FL032P
The following sequences will release the device from Quad I/O High Performance Read mode; after which, the device can accept
standard SPI instructions:
1. During the Quad I/O High Performance Instruction Sequence, if the Mode bits are any value other than Axh, then the next
time CS# is raised high and then asserted low the device will be released from Quad I/O High Performance Read mode.
2. Furthermore, during any operation, if CS# toggles high to low to high for eight cycles (or less) and data input (IO0, IO1,
IO2, & IO3) are not set for a valid instruction sequence, then the device will be released from Quad I/O High Performance
Read mode.
It is important that the I/O pins be set to high-impedance prior to the falling edge of the first data out clock.
The read instruction can be terminated by driving the CS# pin to the logic high state. The CS# pin can be driven high at any time
during data output to terminate a read operation.
Figure 16. QUAD I/O High Performance Instruction Sequence
0
1
2
3
4
5
6
7
8
es
ig
n
CS#
9
13 14 15 16 17 18 19 20 21 22 23 24 25 26
D
SCK
Hi-Z
SO/IO1
20 16
0
4
21 17
1
5
22 18
2
23 19
*
3
W#/ACC/IO2
Hi-Z
4
0
4
0
4
5
1
5
1
5
6
2
6
3
7
2
6
2
7
3
7
3
*
en
d
IO’s Switches from Input to Output
6
ed
HOLD#/IO3
1
fo
Hi-Z
0
rN
SI/IO0
ew
24 Bit
Address
Instruction
Mode Bits DUMMY DUMMY
7
*
*
Byte 1
Byte 2
*
*MSB
ec
om
m
Figure 17. Continuous QUAD I/O High Performance Instruction Sequence
CS#
N
ot
SCK
1
4
5
6
7
8
9
10
11
12
13
14
15
16
R
0
24 Bit
Address
IO’s Switches from Input to Output
20
16
0
4
0
4
0
4
0
4
SO/IO1
21
17
1
5
1
5
1
5
1
5
W#/ACC/IO2
22
18
2
6
2
6
2
6
2
6
HOLD#/IO3
23
*
19
3
7
3
7
3
7
*
Byte 2
*
SI/IO0
* Bits DUMMY
Mode
7
DUMMY
3
*
Byte 1
*MSB
Document Number: 002-00650 Rev. *L
Page 24 of 60
S25FL032P
9.7
Read Identification (RDID)
The Read Identification (RDID) command outputs the one-byte manufacturer identification, followed by the two-byte device
identification and the bytes for the Common Flash Interface (CFI) tables. The manufacturer identification is assigned by JEDEC; for
Cypress devices, it is 01h. The device identification (2 bytes) and CFI bytes are assigned by the device manufacturer.
See Table 11 on page 25 for device ID data.
The Common Flash Interface (CFI) specification outlines device and host system software interrogation handshake, which allows
vendor-specified software algorithms to be used for entire families of devices. Software support can then be device-independent,
JEDEC ID-independent, and forward- and backward-compatible for the specified flash device families. Flash vendors can
standardize their existing interfaces for long-term compatibility. The system can read CFI information at the addresses given in
Table 12.
D
The RDID command sequence is shown in Figure 18 and Table 10 on page 18.
es
ig
n
The host system must first select the device by driving CS# low. The RDID command is then written to SI, and each bit is latched on
the rising edge of SCK. One byte of manufacture identification, two bytes of device identification and sixty-six bytes of extended
device identification are then output from the memory array on SO at a frequency fR, on the falling edge of SCK. The maximum clock
frequency for the RDID (9Fh) command is 50 MHz (Normal Read). The manufacturer ID and Device ID can be read repeatedly by
applying multiples of 648 clock cycles. The manufacturer ID, Device ID and CFI table can be continuously read as long as CS# is
held low with a clock input.
ew
Driving CS# high after the device identification data has been read at least once terminates the RDID command. Driving CS# high at
any time during data output (for example, while reading the extended CFI bytes), also terminates the RDID operation.
fo
rN
The device rejects any RDID command issued while it is executing a program, erase, or Write Registers operation, and continues
the operation uninterrupted.
N
ot
R
ec
om
m
en
d
ed
Figure 18. Read Identification (RDID) Command Sequence and Data-Out Sequence
Table 11. Manufacturer & Device ID - RDID (JEDEC 9Fh)
Device
S25FL032P SPI Flash
Manuf. ID
# Extended
bytes
Device Id
Byte 0
Byte 1
Byte 2
Byte 3
01h
02h
15h
4Dh
Notes
1. Byte 0 is Manufacturer ID of Cypress.
2. Byte 1 & 2 is Device Id.
3. Byte 3 is Extended Device Information String Length, to indicate how many Extended Device Information bytes will follow.
4. Bytes 4, 5 and 6 are Cypress reserved (do not use).
5. For Bytes 07h-0Fh and 3Dh-3Fh, the data will be read as 0xFF.
6. Bytes 10h-50h are factory programmed per JEDEC standard.
Document Number: 002-00650 Rev. *L
Page 25 of 60
S25FL032P
Table 12. Product Group CFI Query Identification String
51h
52h
59h
Description
Query Unique ASCII string “QRY”
13h
14h
02h
00h
Primary OEM Command Set
15h
16h
40h
00h
Address for Primary Extended Table
17h
18h
00h
00h
Alternate OEM Command Set
(00h = none exists)
19h
1Ah
00h
00h
Address for Alternate OEM Extended Table
(00h = none exists)
D
Table 13. Product Group CFI System Interface String
Description
ew
Data
27h
VCC Min. (erase/program): (D7-D4: Volt, D3-D0: 100 mV)
36h
VCC Max. (erase/program): (D7-D4: Volt, D3-D0: 100 mV)
1Dh
00h
VPP Min. voltage (00h = no VPP pin present)
1Eh
00h
VPP Max. voltage (00h = no VPP pin present)
1Fh
0Bh
Typical timeout per single byte program 2N µs
20h
0Bh
Typical timeout for Min. size Page program 2N µs
(00h = not supported)
21h
09h
Typical timeout per individual sector erase 2N ms
22h
0Fh
23h
01h
24h
01h
25h
02h
26h
m
en
d
ed
fo
rN
1Bh
1Ch
ot
Byte
n
Data
10h
11h
12h
es
ig
Byte
ec
om
Typical timeout for full chip erase 2N ms (00h = not supported)
Max. timeout for byte program 2N times typical
R
Max. timeout for page program 2N times typical
N
01h
Max. timeout per individual sector erase 2N times typical
Max. timeout for full chip erase 2N times typical
(00h = not supported)
Table 14. Product Group CFI Device Geometry Definition
Byte
Data
Description
N
byte;
27h
16h
Device Size = 2
28h
05h
29h
05h
Flash Device Interface Description;
00h = x8 only
01h = x16 only
02h = x8/x16 capable
03h = x32 only
04h = Single I/O SPI, 3-byte address
05h = Multi I/O SPI, 3-byte address
2Ah
08h
2Bh
00h
Max. number of bytes in multi-byte write = 2N
(00 = not supported)
2Ch
02h
Number of Erase Block Regions within device
1 = Uniform Device, 2 = Parameter Block
Document Number: 002-00650 Rev. *L
Page 26 of 60
S25FL032P
Table 14. Product Group CFI Device Geometry Definition (Continued)
2Fh
10h
30h
00h
31h
3Dh
32h
00h
33h
00h
34h
01h
35h
00h
36h
00h
37h
00h
38h
00h
39h
00h
3Ah
00h
3Bh
00h
3Ch
00h
Erase Block Region 1 Information (refer to CFI publication 100)
Erase Block Region 2 Information (refer to CFI publication 100)
Erase Block Region 3 Information (refer to CFI publication 100)
n
00h
es
ig
1Fh
2Eh
D
2Dh
Description
Erase Block Region 4 Information (refer to CFI publication 100)
ew
Data
rN
Byte
Data
40h
50h
41h
52h
42h
49h
43h
31h
44h
33h
en
d
m
Query-unique ASCII string “PRI”
R
ec
om
Major version number, ASCII
ot
15h
N
45h
Description
ed
Byte
fo
Table 15. Product Group CFI Primary Vendor-Specific Extended Query
Minor version number, ASCII
Address Sensitive Unlock (Bits 1-0)
00b = Required, 01b = Not Required
Process Technology (Bits 5-2)
0000b = 0.23 µm Floating Gate
0001b = 0.17 µm Floating Gate
0010b = 0.23 µm MirrorBit
0010b = 0.20 µm MirrorBit
0011b = 0.11 µm Floating Gate
0100b = 0.11 µm MirrorBit
0101b = 0.09 µm MirrorBit
1000b = 0.065 µm MirrorBit
46h
00h
Erase Suspend
0 = Not Supported, 1 = Read Only, 2 = Read & Write
47h
01h
Sector Protect
00 = Not Supported, X = Number of sectors in per smallest group
48h
00h
Temporary Sector Unprotect
00 = Not Supported, 01 = Supported
49h
05h
Sector Protect/Unprotect Scheme
04 = High Voltage Method
05 = Software Command Locking Method
08 = Advanced Sector Protection Method
4Ah
00h
Simultaneous Operation
00 = Not Supported, X = Number of Sectors outside Bank 1
4Bh
01h
Burst Mode Type
00 = Not Supported, 01 = Supported
Document Number: 002-00650 Rev. *L
Page 27 of 60
S25FL032P
Table 15. Product Group CFI Primary Vendor-Specific Extended Query (Continued)
Byte
Data
Description
4Ch
03h
Page Mode Type
00 = Not Supported, 01 = 4 Word Page, 02 = 8 Word Page,
03 = 256 Byte Page
4Dh
85h
ACC (Acceleration) Supply Minimum
00 = Not Supported, (D7-D4: Volt, D3-D0: 100 mV)
4Eh
95h
ACC (Acceleration) Supply Maximum
00 = Not Supported, (D7-D4: Volt, D3-D0: 100 mV)
4Fh
07h
W# Protection
07 = Uniform Device with Top or Bottom Write Protect (user select)
50h
00h
Program Suspend
00 = Not Supported, 01 = Supported
Read-ID (READ_ID)
D
9.8
es
ig
n
Note
CFI data related to VCC and time-outs may differ from actual VCC and time-outs of the product. Please consult the Ordering Information tables to obtain the VCC range for
particular part numbers. Refer to Section 18., AC Characteristics on page 49 for typical timeout specifications.
ew
The READ_ID instruction provides the S25FL032P manufacturer and device information and is provided as an alternative to the
Release from Deep Power-Down and Read Electronic Signature (RES), and the JEDEC Read Identification (RDID) commands.
m
en
d
ed
fo
rN
The instruction is initiated by driving the CS# pin low and shifting in (via the SI input pin) the instruction code “90h” followed by a
24-bit address (which is either 00000h or 00001h). Following this, the Manufacturer ID and the Device ID are shifted out on the SO
output pin starting after the falling edge of the SCK serial clock input signal. If the 24-bit address is set to 000000h, the Manufacturer
ID is read out first followed by the Device ID. If the 24-bit address is set to 000001h, then the Device ID is read out first followed by
the Manufacturer ID. The Manufacturer ID and Device ID are always shifted out on the SO output pin with the MSB first, as shown in
Figure 10-14. Once the device is in Read-ID mode, the Manufacturer ID and Device ID output data toggle between address
000000H and 000001H until terminated by a low to high transition on the CS# input pin. The maximum clock frequency for the
Read-ID (90h) command is at 104 MHz (FAST_READ). The Manufacturer ID and Device ID are output continuously until terminated
by a low to high transition on CS# chip select input pin.
CS#
1
2
3
4
5
6
7
8
9
10
28 29 30 31 32 33 34 35 36 37 38 39 40 41 42 43 44 45 46 47
R
0
ec
om
Figure 19. Read-ID (RDID) Command Timing Diagram
ot
SCK
24-Bit Address
N
Instruction
SI
23 22 21
MSB
3
2
1
0
Manufacture Identification
Device Identification
High Impedance
7
SO
6
5
4
3
2
1
0
Table 16. READ_ID Data-Out Sequence
Address
Uniform
Manufacturer Identification
00000h
01h
Device Identification
00001h
15h
Document Number: 002-00650 Rev. *L
Page 28 of 60
S25FL032P
9.9
Write Enable (WREN)
The Write Enable (WREN) command (see Figure 20) sets the Write Enable Latch (WEL) bit to a 1, which enables the device to
accept a Write Status Register, program, or erase command. The WEL bit must be set prior to every Page Program (PP), Quad
Page Program (QPP), Parameter Sector Erase (P4E, P8E), Erase (SE or BE), Write Registers (WRR), and OTP Program (OTPP)
command. The host system must first drive CS# low, write the WREN command, and then drive CS# high.
Figure 20. Write Enable (WREN) Command Sequence
CS#
0
Mode 3
SCK
1
2
3
4
5
6
7
Mode 0
Command
es
ig
n
SI
Hi-Z
Write Disable (WRDI)
ew
9.10
D
SO
fo
rN
The Write Disable (WRDI) command (see Figure 21) resets the Write Enable Latch (WEL) bit to a 0, which disables the device from
accepting a Page Program (PP), Quad Page Program (QPP), Parameter Sector Erase (P4E, P8E), Erase (SE, BE), Write Registers
(WRR), and OTP Program (OTPP) command. The host system must first drive CS# low, write the WRDI command, and then drive
CS# high.
ed
Any of following conditions resets the WEL bit:
en
d
Power-up
Write Disable (WRDI) command completion
ec
om
Page Program (PP) command completion
m
Write Registers (WRR) command completion
Quad Page Program (QPP) completion
Parameter Sector Erase (P4E, P8E) completion
R
Sector Erase (SE) command completion
ot
Bulk Erase (BE) command completion
N
OTP Program (OTPP) completion
Figure 21. Write Disable (WRDI) Command Sequence
CS#
Mode 3
0 1 2 3 4 5 6 7
SCK Mode 0
Command
SI
Hi-Z
SO
Document Number: 002-00650 Rev. *L
Page 29 of 60
S25FL032P
9.11
Read Status Register (RDSR)
The Read Status Register (RDSR) command outputs the state of the Status Register bits. Table 17 shows the status register bits
and their functions. The RDSR command may be written at any time, even while a program, erase, or Write Registers operation is in
progress. The host system should check the Write In Progress (WIP) bit before sending a new command to the device if an
operation is already in progress. Figure 22 shows the RDSR command sequence, which also shows that it is possible to read the
Status Register continuously until CS# is driven high. The maximum clock frequency for the RDSR command is
104 MHz.
Table 17. S25FL032P Status Register
Status Register Bit
Bit Function
Description
7
SRWD
Status Register Write Disable
1 = Protects when W#/ACC is low
0 = No protection, even when W#/ACC is low
6
P_ERR
Programming Error Occurred
0 = No Error
1 = Error occurred
5
E_ERR
Erase Error Occurred
0 = No Error
1 = Error occurred
4
BP2
3
BP1
2
BP0
1
WEL
Write Enable Latch
1 = Device accepts Write Registers, program or erase commands
0 = Ignores Write Registers, program or erase commands
0
WIP
Write in Progress
1 = Device Busy a Write Registers, program or erase operation
is in progress
0 = Ready. Device is in standby mode and can accept commands.
D
es
ig
n
Bit
Protects selected Block from Program or Erase
en
d
ed
fo
rN
ew
Block Protect
m
Figure 22. Read Status Register (RDSR) Command Sequence
Mode 3
SCK
0 1
2
3
Mode 0
ec
om
CS#
4
5
6
7
8
9 10 11 12 13 14 15
R
Command
N
ot
SI
SO
Hi-Z
7 6 5 4 3 2 1 0 7 6 5 4 3 2 1 0 7
MSB
Status Register Out
MSB
Status Register Out
The following describes the status and control bits of the Status Register.
Write In Progress (WIP) bit: Indicates whether the device is busy performing a Write Registers, program, or erase operation. This
bit is read-only, and is controlled internally by the device. If WIP is 1, one of these operations is in progress; if WIP is 0, no such
operation is in progress. This bit is a Read-only bit.
Write Enable Latch (WEL) bit: Determines whether the device will accept and execute a Write Registers, program, or erase
command. When set to 1, the device accepts these commands; when set to 0, the device rejects the commands. This bit is set to 1
by writing the WREN command, and set to 0 by the WRDI command, and is also automatically reset to 0 after the completion of a
Write Registers, program, or erase operation, and after a power down/power up sequence. WEL cannot be directly set by the WRR
command.
Document Number: 002-00650 Rev. *L
Page 30 of 60
S25FL032P
Block Protect (BP2, BP1, BP0) bits: Define the portion of the memory area that will be protected against any changes to the stored
data. The Block Protection (BP2, BP1, BP0) bits are either volatile or non-volatile, depending on the state of the nonvolatile bit BPNV
in the Configuration register. The Block Protection (BP2, BP1, BP0) bits are written with the Write Registers (WRR) instruction.
When one or more of the Block Protect (BP2, BP1, BP0) bits is set to 1’s, the relevant memory area is protected against Page
Program (PP), Parameter Sector Erase (P4E, P8E), Sector Erase (SE), Quad Page Programming (QPP) and Bulk Erase (BE)
instructions. If the Hardware Protected mode is enabled, BP2:BP0 cannot be changed.
The Bulk Erase (BE) instruction can be executed only when the Block Protection (BP2, BP1, BP0) bits are set to 0s. The default
condition of the BP2-0 bits is binary 000 (all 0s).
Erase Error bit (E_ERR): The Erase Error Bit is used as a Erase operation success and failure check. When the Erase Error bit is
set to a “1”, it indicates that there was an error which occurred in the last erase operation. With the Erase Error bit set to a “1”, this bit
is reset with the Clear Status Register (CLSR) command.
n
Program Error bit (P_ERR): The Program Error Bit is used as a Program operation success and failure check. When the Program
Error bit is set to a “1”, it indicates that there was an error which occurred in the last program operation. With the Program Error bit
set to a “1”, this bit is reset with the Clear Status Register (CLSR) command.
rN
ew
D
es
ig
Status Register Write Disable (SRWD) bit: Provides data protection when used together with the Write Protect (W#/ACC) signal.
The Status Register Write Disable (SRWD) bit is operated in conjunction with the Write Protect (W#/ACC) input pin. The Status
Register Write Disable (SRWD) bit and the Write Protect (W#/ACC) signal allow the device to be put in the Hardware Protected
mode. With the Status Register Write Disable (SRWD) bit set to a “1” and the W#/ACC driven to the logic low state, the device enters
the Hardware Protected mode; the non-volatile bits of the Status Register (SRWD, BP2, BP1, BP0) and the nonvolatile bits of the
Configuration Register (TBPARM, TBPROT, BPNV and QUAD) become read-only bits and the Write Registers (WRR) instruction
opcode is no longer accepted for execution.
Read Configuration Register (RCR)
ed
9.12
fo
Note: The P_ERR and E_ERR bits will not be set to a 1 if the application writes to a protected memory area.
ec
om
m
en
d
The Read Configuration Register (RCR) instruction opcode allows the Configuration Register contents to be read out of the SO
serial output pin. The Configuration Register contents may be read at any time, even while a program, erase, or write cycle is in
progress. When one of these cycles is in progress, it is recommended to the user to check the Write In Progress (WIP) bit of the
Status Register before issuing a new instruction opcode to the device. The Configuration Register originally shows 00h when the
device is first shipped from the factory to the customer. Refer to Section 7.8 on page 12 for more details.
Figure 23. Read Configuration Register (RCR) Instruction Sequence
R
CS#
2
3
ot
1
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20
21
22
23
1
0
N
0
SCK
In st r u ct i o n
SI
Configuration Register Out
Configuration Register Out
SO
High Impedance
7
MSB
Document Number: 002-00650 Rev. *L
6
5
4
3
2
1
0
7
MSB
6
5
4
3
2
7
MSB
Page 31 of 60
S25FL032P
9.13
Write Registers (WRR)
The Write Registers (WRR) command allows changing the bits in the Status and Configuration Registers. A Write Enable (WREN)
command, which itself sets the Write Enable Latch (WEL) in the Status Register, is required prior to writing the WRR command.
Table 17 shows the status register bits and their functions.
The host system must drive CS# low, then write the WRR command and the appropriate data byte on SI Figure 24.
The WRR command cannot change the state of the Write Enable Latch (bit 1). The WREN command must be used for that purpose.
The Status Register consists of one data byte in length; similarly, the Configuration Register is also one data byte in length. The CS#
pin must be driven to the logic low state during the entire duration of the sequence.
The WRR command also controls the value of the Status Register Write Disable (SRWD) bit. The SRWD bit and W#/ACC pin
together place the device in the Hardware Protected Mode (HPM). The device ignores all WRR commands once it enters the
Hardware Protected Mode (HPM). Table 18 shows that W#/ACC must be driven low and the SRWD bit must be 1 for this to occur.
es
ig
n
The Write Registers (WRR) instruction has no effect on the P/E Error and the WIP bits of the Status & Configuration Registers. Any
bit reserved for the future is always read as a ‘0’
fo
rN
ew
D
The CS# chip select input pin must be driven to the logic high state after the eighth (see Figure 24) or sixteenth (see Figure 25) bit of
data has been latched in. If not, the Write Registers (WRR) instruction is not executed. If CS# is driven high after the eighth cycle
then only the Status Register is written to; otherwise, after the sixteenth cycle both the Status and Configuration Registers are
written to. As soon as the CS# chip select input pin is driven to the logic high state, the self-timed Write Registers cycle is initiated.
While the Write Registers cycle is in progress, the Status Register may still be read to check the value of the Write In Progress (WIP)
bit. The Write In Progress (WIP) bit is a ‘1’ during the self-timed Write Registers cycle, and is a ‘0’ when it is completed. When the
Write Registers cycle is completed, the Write Enable Latch (WEL) is set to a ‘0’. The WRR command can operate at a maximum
clock frequency of 104 MHz.
ed
Figure 24. Write Registers (WRR) Instruction Sequence – 8 data bits
1
2
3
4
5
6
7
8
9
ec
om
0
m
en
d
CS#
SCK
11
12
13
14
15
St at u s Regi st er In
ot
R
In st r u ct i o n
10
7
N
SI
6
5
4
3
2
1
0
MSB
High Impedance
SO
Figure 25. Write Registers (WRR) Instruction Sequence – 16 data bits
CS
S#
0
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20
21
22
23
SCK
Instruction
SI
Status Register In
7
MSB
SO
6
5
4
3
2
Configuration Register In
1
0
7
6
5
4
3
2
1
0
MSB
High Impedance
Document Number: 002-00650 Rev. *L
Page 32 of 60
S25FL032P
Table 18. Protection Modes
W#/ACC SRWD
Bit
1
Write Protection of Registers
Software
Protected
(SPM)
Hardware
Protected
(HPM)
1
1
0
0
0
0
Mode
1
Memory Content
Protected Area
Unprotected Area
Status & Configuration Registers are
Writable (if WREN instruction has set the
WEL bit). The values in the SRWD, BP2,
BP1, & BP0 bits & those in the Configuration
Register can be changed
Protected against Page
Program, Parameter
Sector Erase, Sector
Erase, and Bulk Erase
Ready to accept Page
Program, Parameter
Sector Erase, & Sector
Erase instructions
Status & Configuration Registers are
Hardware Write Protected. The values in the
SRWD, BP2, BP1, & BP0 bits & those in the
Configuration Register cannot be changed
Protected against Page
Program, Parameter
Sector Erase, Sector
Erase, and Bulk Erase
Ready to accept Page
Program, Parameter
Sector Erase, Sector
Erase instructions
es
ig
n
Note
As defined by the values in the Block Protect (BP2, BP1, BP0) bits of the Status Register, as shown in Table 6 on page 14.
D
Table 18 shows that neither W#/ACC or SRWD bit by themselves can enable HPM. The device can enter HPM either by setting the
SRWD bit after driving W#/ACC low, or by driving W#/ACC low after setting the SRWD bit. However, the device disables HPM only
when W#/ACC is driven high.
rN
ew
Note that HPM only protects against changes to the status register. Since BP2:BP0 cannot be changed in HPM, the size of the
protected area of the memory array cannot be changed. Note that HPM provides no protection to the memory array area outside that
specified by BP2:BP0 (Software Protected Mode, or SPM).
ed
fo
If W#/ACC is permanently tied high, HPM can never be activated, and only the SPM (BP2:BP0 bits of the Status Register) can be
used. The Status and Configuration registers originally default to 00h, when the device is first shipped from the factory to the
customer.
Page Program (PP)
m
9.14
en
d
Note: HPM is disabled when the Quad I/O Mode is enabled (Quad bit = 1 in the Configuration Register).
W# becomes IO2; therefore, HPM cannot be utilized.
ec
om
The Page Program (PP) command changes specified bytes in the memory array (from 1 to 0 only). A WREN command is required
prior to writing the PP command.
ot
R
The host system must drive CS# low, and then write the PP command, three address bytes, and at least one data byte on SI. If the
8 least significant address bits (A7-A0) are not all zero, all transmitted data that goes beyond the end of the currently selected page
are programmed from the starting address of the same page (from the address whose 8 least significant bits are all zero). CS# must
be driven low for the entire duration of the PP sequence. The command sequence is shown in Figure 26 and Table 10 on page 18.
N
The device programs only the last 256 data bytes sent to the device. If the 8 least significant address bits (A7-A0) are not all zero, all
transmitted data that goes beyond the end of the currently selected page are programmed from the starting address of the same
page (from the address whose 8 least significant bits are all zero). If fewer than 256 data bytes are sent to device, they are correctly
programmed at the requested addresses without having any effect on the other bytes in the same page.
The host system must drive CS# high after the device has latched the 8th bit of the data byte, otherwise the device does not execute
the PP command. The PP operation begins as soon as CS# is driven high. The device internally controls the timing of the operation,
which requires a period of tPP. The Status Register may be read to check the value of the Write In Progress (WIP) bit while the PP
operation is in progress. The WIP bit is 1 during the PP operation, and is 0 when the operation is completed. The device internally
resets the Write Enable Latch to 0 before the operation completes (the exact timing is not specified).
The device does not execute a Page Program (PP) command that specifies a page that is protected by the Block Protect bits
(BP2:BP0) (see Table 6 on page 14).
Document Number: 002-00650 Rev. *L
Page 33 of 60
S25FL032P
Figure 26. Page Program (PP) Command Sequence
CS#
0
Mode 3
5
4
3
6
8
7
28 29 30 31 32 33 34 35 36 37 38
9 10
24 Bit Address
3
23 22 21
2
1
0
MSB
5
4
3
2
0
7
6
5
4
2
1
0
3
2
n
2079
2078
2076
D
1
0
7
6
Data Byte 256
5
4
3
2
1
0
MSB
MSB
N
ot
R
ec
om
m
en
d
ed
fo
MSB
Data Byte 3
1
3
2077
55
ew
6
4
rN
7
5
2075
2072
51 52 53 54
SCK
Data Byte 2
6
MSB
CS#
40 41 42 43 44 45 46 47 48 49 50
7
es
ig
SI
Data Byte 1
2074
Command
SI
39
Mode 0
2073
SCK
2
1
Document Number: 002-00650 Rev. *L
Page 34 of 60
S25FL032P
9.15
QUAD Page Program (QPP)
The Quad Page Program instruction is similar to the Page Program instruction, except that the Quad Page Program (QPP)
instruction allows up to 256 bytes of data to be programmed at previously erased (FFh) memory locations using four pins: IO0 (SI),
IO1 (SO), IO2 (W#/ACC), and IO3 (HOLD#), instead of just one pin (SI) as in the case of the Page Program (PP) instruction. This
effectively increases the data transfer rate by up to four times, as compared to the Page Program (PP) instruction. The QPP feature
can improve performance for PROM Programmer and applications that have slow clock speeds < 5 MHz. Systems with faster clock
speed will not realize much benefit for the QPP instruction since the inherent page program time is much greater than the time it take
to clock-in the data.
To use QPP, the Quad Enable Bit in the Configuration Register must be set (QUAD = 1). A Write Enable instruction must be
executed before the device will accept the Quad Page Program instruction (Status Register-1, WEL = 1). The instruction is initiated
by driving the CS# pin low then shifting the instruction code “32h” followed by a 24 bit address (A23-A0) and at least one data byte,
into the IO pins. The CS# pin must be held low for the entire length of the instruction while data is being sent to the device. All other
functions of Quad Input Page Program are identical to standard Page Program. The QPP instruction sequence is shown below.
es
ig
n
Figure 27. QUAD Page Program Instruction Sequence
CS#
1
2
4
3
5
6
7
8
9
28
10
29
30
23 22
*
W#/ACC/IO2
HOLD#/IO3
32
33
34
35
36
37
38
39
4
0
4
0
4
0
4
0
5
1
5
1
6
2
7
3
ew
1
0
5
5
1
6
7
1
2
6
2
6
2
3
7
3
7
3
*
Byte 1
*
Byte 2
*
Byte 3
*
Byte 4
ot
4
1
N
5
6
7
2
0
50
51
52
53
54
55
4
0
4
0
4
0
4
0
4
0
4
0
4
0
4
1
5
1
5
1
5
1
5
1
2
6
2
6
2
6
2
6
2
5
1
5
1
5
6
2
6
2
6
2
6
3
*
Byte 6
7
3
*
Byte 7
7
3
*
Byte 8
7
3
*
Byte 9
7
3
*
Byte 10
7
3
*
Byte 11
7
3
*
Byte 12
7
3
543
49
542
48
541
47
540
46
539
45
1
7
538
44
5
3
*
Byte 5
43
537
4
0
42
536
m
41
SCK
SO/IO1
ec
om
40
R
CS#
W#/ACC/IO2
2
en
d
HOLD#/IO3
SI/IO0
3
ed
SO/IO1
21
fo
SI/IO0
rN
24 Bit
Address
Instruction
31
D
0
SCK
0
4
0
4
0
5
1
5
1
5
1
6
2
6
2
6
7
3
7
3
7
2
3
*
*
*
*
Byte 253 Byte 254 Byte 255 Byte 256
*MSB
Document Number: 002-00650 Rev. *L
Page 35 of 60
S25FL032P
9.16
Parameter Sector Erase (P4E, P8E)
The Parameter Sector Erase (P4E, P8E) command sets all bits at all addresses within a specified sector to a logic 1 (FFh). A WREN
command is required prior to writing the Parameter Sector Erase commands.
The host system must drive CS# low, and then write the P4E or P8E command, plus three address bytes on SI. Any address within
the sector (see Table 8 on page 16 and Table 9 on page 17) is a valid address for the P4E or P8E command. CS# must be driven
low for the entire duration of the P4E/P8E sequence. The command sequence is shown in Figure 28 and Table 10 on page 18.
The host system must drive CS# high after the device has latched the 24th bit of the P4E/P8E address, otherwise the device does
not execute the command. The parameter sector erase operation begins as soon as CS# is driven high. The device internally
controls the timing of the operation, which requires a period of tSE. The Status Register may be read to check the value of the Write
In Progress (WIP) bit while the parameter sector erase operation is in progress. The WIP bit is 1 during the P4E/P8E operation, and
is 0 when the operation is completed. The device internally resets the Write Enable Latch to 0 before the operation completes (the
exact timing is not specified).
es
ig
n
A Parameter Sector Erase (P4E, P8E) instruction applied to a sector that has been Write Protected through the Block Protect Bits
will not be executed.
rN
ew
D
The Parameter Sector Erase Command (P8E) erases two of the 4 KB Sectors in selected address space. The Parameter Sector
Erase Command (P8E) erases two sequential 4 KB Parameter Sectors in the selected address space. The address LSB is
disregarded so that two sequential 4 KB Parameter Sectors are erased. The 24 Bit Address is any location within the first Sector to
be erased (n), and the next sequential 4 KB Parameter Sector will also be erased (n+1). The 4 KB parameter Sector will only be
erased properly if n or n+1 is a valid 4 KB parameter Sector; that is, if n is not a valid 4K parameter Sector, then it will not be erased.
If n+1 is not a valid 4 KB parameter Sector, then it will not be erased.
fo
Figure 28. Parameter Sector Erase (P4E, P8E) Instruction Sequence
0
1
2
3
4
5
6
7
8
m
SCK
en
d
ed
CS#
ec
om
Instruction
SI
10
28 29 30 31
24 Bit Address
23 22 21
3
2
1
0
MSB
N
ot
R
20h or 40h
9
Document Number: 002-00650 Rev. *L
Page 36 of 60
S25FL032P
9.17
Sector Erase (SE)
The Sector Erase (SE) command sets all bits at all addresses within a specified sector to a logic 1. A WREN command is required
prior to writing the SE command.
The host system must drive CS# low, and then write the SE command plus three address bytes on SI. Any address within the sector
(see Table 6 on page 14) is a valid address for the SE command. CS# must be driven low for the entire duration of the SE sequence.
The command sequence is shown in Figure 29 and Table 10 on page 18.
The host system must drive CS# high after the device has latched the 24th bit of the SE address, otherwise the device does not
execute the command. The SE operation begins as soon as CS# is driven high. The device internally controls the timing of the
operation, which requires a period of tSE. The Status Register may be read to check the value of the Write In Progress (WIP) bit
while the SE operation is in progress. The WIP bit is 1 during the SE operation, and is 0 when the operation is completed. The
device internally resets the Write Enable Latch to 0 before the operation completes (the exact timing is not specified).
n
The device only executes a SE command if all Block Protect bits (BP2:BP0) are 0 (see Table 6 on page 14). Otherwise, the device
ignores the command.
es
ig
Figure 29. Sector Erase (SE) Command Sequence
1
2
3
4
5
6
7
8
9
10
28
29
30
31
1
0
ew
0
Mode 3
SCK
D
CS#
Mode 0
24 bit Address
rN
Command
SI
22
21
3
2
fo
23
9.18
Hi-Z
en
d
SO
ed
MSB
Bulk Erase (BE)
ec
om
m
The Bulk Erase (BE) command sets all the bits within the entire memory array to logic 1s. A WREN command is required prior to
writing the BE command.
The host system must drive CS# low, and then write the BE command on SI. CS# must be driven low for the entire duration of the
BE sequence. The command sequence is shown in Figure 30 and Table 10 on page 18.
N
ot
R
The host system must drive CS# high after the device has latched the 8th bit of the CE command, otherwise the device does not
execute the command. The BE operation begins as soon as CS# is driven high. The device internally controls the timing of the
operation, which requires a period of tBE. The Status Register may be read to check the value of the Write In Progress (WIP) bit
while the BE operation is in progress. The WIP bit is 1 during the BE operation, and is 0 when the operation is completed. The
device internally resets the Write Enable Latch to 0 before the operation completes (the exact timing is not specified).
The device only executes a BE command if all Block Protect bits (BP2:BP0) are 0 (see Table 6 on page 14). Otherwise, the device
ignores the command.
Figure 30. Bulk Erase (BE) Command Sequence
CS#
Mode 3
SCK
0
1
2
3
4
5
6
7
Mode 0
Command
SI
SO
Document Number: 002-00650 Rev. *L
Hi-Z
Page 37 of 60
S25FL032P
9.19
Deep Power-Down (DP)
The Deep Power-Down (DP) command provides the lowest power consumption mode of the device. It is intended for periods when
the device is not in active use, and ignores all commands except for the Release from Deep Power-Down (RES) command. The DP
mode therefore provides the maximum data protection against unintended write operations. The standard standby mode, which the
device goes into automatically when CS# is high (and all operations in progress are complete), should generally be used for the
lowest power consumption when the quickest return to device activity is required.
The host system must drive CS# low, and then write the DP command on SI. CS# must be driven low for the entire duration of the
DP sequence. The command sequence is shown in Figure 31 and Table 10 on page 18.
The host system must drive CS# high after the device has latched the 8th bit of the DP command, otherwise the device does not
execute the command. After a delay of tDP, the device enters the DP mode and current reduces from ISB to IDP (see Table 23 on
page 47).
es
ig
n
Once the device has entered the DP mode, all commands are ignored except the RES command (which releases the device from
the DP mode). The RES command also provides the Electronic Signature of the device to be output on SO, if desired (see
Section 9.20 and Section 9.21).
D
DP mode automatically terminates when power is removed, and the device always powers up in the standard standby mode. The
device rejects any DP command issued while it is executing a program, erase, or Write Registers operation, and continues the
operation uninterrupted.
ew
Figure 31. Deep Power-Down (DP) Command Sequence
Mode 0
2
3
4
5
6
tDP
7
en
d
SCK
1
ed
0
Mode 3
fo
rN
CS#
ec
om
m
Command
Hi-Z
N
ot
SO
R
SI
Document Number: 002-00650 Rev. *L
Standby Mode
Deep Power-down Mode
Page 38 of 60
S25FL032P
9.20
Release from Deep Power-Down (RES)
The device requires the Release from Deep Power-Down (RES) command to exit the Deep Power-Down mode. When the device is
in the Deep Power-Down mode, all commands except RES are ignored.
The host system must drive CS# low and write the RES command to SI. CS# must be driven low for the entire duration of the
sequence. The command sequence is shown in Figure 32 and Table 10 on page 18.
The host system must drive CS# high tRES(max) after the 8-bit RES command byte. The device transitions from DP mode to the
standby mode after a delay of tRES (see Figure 25). In the standby mode, the device can execute any read or write command.
Note: The RES command does not reset the Write Enable Latch (WEL) bit.
Figure 32. Release from Deep Power-Down (RES) Command Sequence
CS#
0
2
1
3
5
4
7
6
n
Mode 3
SCK
es
ig
Mode 0
tRES
D
Command
ew
SI
Hi-Z
rN
SO
Deep Power-down Mode
Release from Deep Power-Down and Read Electronic Signature (RES)
en
d
9.20.1
ed
fo
Standby Mode
ec
om
m
The device features an 8-bit Electronic Signature, which can be read using the RES command. See Figure 33 and Table 10 on page
18 for the command sequence and signature value. The Electronic Signature is not to be confused with the identification data
obtained using the RDID command. The device offers the Electronic Signature so that it can be used with previous devices that
offered it; however, the Electronic Signature should not be used for new designs, which should read the RDID data instead.
R
After the host system drives CS# low, it must write the RES command followed by 3 dummy bytes to SI (each bit is latched on SI
during the rising edge of SCK). The Electronic Signature is then output on SO; each bit is shifted out on the falling edge of SCK. The
RES operation is terminated by driving CS# high after the Electronic Signature is read at least once. Additional clock cycles on SCK
with CS# low cause the device to output the Electronic Signature repeatedly.
N
ot
When CS# is driven high, the device transitions from DP mode to the standby mode after a delay of tRES, as previously described.
The RES command always provides access to the Electronic Signature of the device and can be applied even if DP mode has not
been entered. Any RES command issued while an erase, program, or Write Registers operation is in progress not executed, and the
operation continues uninterrupted.
Figure 33. Release from Deep Power-Down and RES Command Sequence
CS#
0
1
2
3
4
5
6
7
8
9
10
28 29 30 31 32 33 34 35 36 37 38 39
SCK
SI
tRES
3 Dummy Bytes
Command
23 22 21
3
2
1
0
MSB
SO
Hi-Z
Electronic ID
7
6
5
4
3
2
1
0
MSB
Deep Power-Down Mode
Document Number: 002-00650 Rev. *L
Standby Mode
Page 39 of 60
S25FL032P
9.21
Clear Status Register (CLSR)
The Clear Status Register command resets bit SR5 (Erase Fail Flag) and bit SR6 (Program Fail Flag). It is not necessary to set the
WEL bit before the Clear SR Fail Flags command is executed. The WEL bit will be unchanged after this command is executed. This
command also resets the State machine and loads latches
Figure 34. Clear Status Register (CLSR) Instruction Sequence
CS
S#
0
1
2
3
4
5
6
7
SCK
Instruction
es
ig
9.22
n
SI
OTP Program (OTPP)
rN
ew
D
The OTP Program command programs data in the OTP region, which is in a different address space from the main array data. Refer
to, Section 10., OTP Regions on page 41 for details on the OTP region. The protocol of the OTP Program command is the same as
the Page Program command, except that the OTP Program command requires exactly one byte of data; otherwise, the command
will be ignored. To program the OTP in bit granularity, the rest of the bits within the data byte can be set to “1”.
fo
The OTP memory space can be programmed one or more times, provided that the OTP memory space is not locked (as described
in “Locking OTP Regions”). Subsequent OTP programming can be performed only on the unprogrammed bits (that is, “1” data).
ed
Note: The Write Enable (WREN) command must precede the OTPP command before programming of the OTP can occur.
en
d
Figure 35. OTP Program Instruction Sequence
1
2
3
4
5
6
7
ec
om
0
m
CS#
SCK
8
9
10
24 Bit
Address
Instruction
Data Byte 1
3
2
1
0
7
6
5
4
3
2
1
0
MSB
ot
MSB
Read OTP Data Bytes (OTPR)
N
9.23
23 22 21
R
SI
28 29 30 31 32 33 34 35 36 37 38 39
The Read OTP Data Bytes command reads data from the OTP region. Refer to Section 10. for details on the OTP region. The
protocol of the Read OTP Data Bytes command is the same as the Fast Read Data Bytes command except that it will not wrap to
the starting address after the OTP address is at its maximum; instead, the data will be indeterminate.
Figure 36. Read OTP Instruction Sequence
CS
0
1
2
3
4
5
6
7
8
9
10
28 29 30 31 32 33 34 35 36 37 38 39 40 41 42 43 44 45 46 47
SCK
24 Bit
Address
Instruction
23 22 21
SI
3
Dummy Byte
2
1
0
7
6
5
4
3
2
1
0
DATA OUT 1
SO
High Impedance
7
MSB
Document Number: 002-00650 Rev. *L
6
5
4
3
2
DATA OUT 2
1
0
7
MSB
Page 40 of 60
S25FL032P
10. OTP Regions
The OTP Regions are separately addressable from the main array and consists of two 8-byte (ESN), thirty 16-byte, and one 10-byte
regions that can be individually locked.
The two 8-byte ESN region is a special order part (please contact your local Cypress sales representative for further details). The
two 8-byte regions enable permanent part identification through an Electronic Serial Number (ESN). The customer can utilize the
ESN to pair a Flash device with the system CPU/ASIC to prevent system cloning. The Cypress factory programs and locks the
lower 8-byte ESN with a 64-bit randomly generated, unique number. The upper 8-byte ESN is left blank for customer use or, if
special ordered, Cypress can program (and lock) in a unique customer ID.
Table 19. ESN1 and ESN2
Lock register ESN1 (Bit 0) Lock register ESN2 (Bit 1) ESN1 region contains
1h
1h
0h
Special order part
1h
1h/0h
Unique random pattern
The thirty 16-byte and one 10-byte OTP regions are open for the customer usage.
ESN2 region contains
0h
Factory/Customer
programmed pattern
es
ig
n
Standard part
ew
D
The thirty 16-byte, one 10-byte, and upper 8-byte ESN OTP regions can be individually locked by the end user. Once locked, the
data cannot changed. The locking process is permanent and cannot be undone.
The following general conditions should be noted with respect to the OTP Regions:
fo
rN
On power-up, or following a hardware reset, or at the end of an OTPP or an OTPR command, the device reverts to sending
commands to the normal address space.
Reads or Programs outside of the OTP Regions will be ignored
ed
The OTP Region is not accessible when the device is executing an Embedded Program or Embedded Erase algorithm.
en
d
The ACC function is not available when accessing the OTP Regions.
10.1
ec
om
m
The thirty 16-byte and one 10-byte OTP regions are left open for customer usage, but special care of the OTP locking must be
maintained, or else a malevolent user can permanently lock the OTP regions. This is not a concern, if the OTP regions are not
used.
Programming OTP Address Space
N
ot
R
The protocol of the OTP Program command (42h) is the same as the Page Program command. Refer to Table 10 for the command
description and protocol. The OTP Program command can be issued multiple times to any given OTP address, but this address
space can never be erased. After a given OTP region is programmed, it can be locked to prevent further programming with the OTP
lock registers (refer to Section 10.3). The valid address range for OTP Program is depicted in the figure below. OTP Program
operations outside the valid OTP address range will be ignored.
10.2
Reading OTP Data
The protocol of the OTP Read command (4Bh) is the same as that of the Fast Read command. Refer to Table 10 for the command
description and protocol. The valid address range for OTP Reads is depicted in the figure below. OTP Read operations outside the
valid OTP address range will yield indeterminate data.
Document Number: 002-00650 Rev. *L
Page 41 of 60
S25FL032P
10.3
Locking OTP Regions
In order to permanently lock the ESN and OTP regions, individual bits at the specified addresses can be set to lock specific regions
of OTP memory, as highlighted in Figure 37 and Figure 38.
Figure 37. OTP Memory Map - Part 1
OT P R EGION
ADDRESS
0x213h
16 bytes (OTP16)
0x204h
0x203h
16 bytes (OTP15)
0x1F4h
0x1F3h
16 bytes (OTP14)
0x1E4h
0x1E3
16 bytes (OTP13)
es
ig
n
0x1D4h
0x1D3h
16 bytes (OTP12)
0x1C4h
0x1C3h
D
16 bytes (OTP11)
ew
0x1B4h
0x1B3h
16 bytes (OTP10)
rN
0x1A4h
0x1A3h
16 bytes (OTP9)
fo
0x194h
0x193h
16 bytes (OTP7)
en
d
0x174h
0x173h
ed
16 bytes (OTP8)
0x184h
0x183h
16 bytes (OTP6)
m
0x164h
0x163h
ec
om
16 bytes (OTP5)
0x154h
0x153h
16 bytes (OTP4)
0x144h
0x143h
Address
0x112h
R
16 bytes (OTP3)
ot
0x134h
0x133h
N
16 bytes (OTP2)
0x124h
0x123h
16 bytes (OTP1)
0x114h
0x113h
0x112h
0x111h
0x113h
Bit 7 Bit 6 Bit 5 Bit 4 Bit 3 Bit 2 Bit 1 Bit 0
Bit 7 Bit 6 Bit 5 Bit 4 Bit 3 Bit 2 Bit 1 Bit 0
8 bytes (ES N2)
0x10Ah
0x109h
8 bytes (ES N1)
0x102h
0x101h
0x100h
0x100h
Reserved
X
X
X
X
X
X
Bit 1 Bit 0
B it
0
1
2
3
4
5
6
7
0
1
2
3
4
5
6
7
0
1
2- 7
Locks R egion…
OTP1
OTP2
OTP3
OTP4
OTP5
OTP6
OTP7
OTP8
OTP9
OTP10
OTP11
OTP12
OTP13
OTP14
OTP15
OTP16
ESN1
ES N2
R eserved
Notes
1. Bit 0 at address 0x100h locks ESN1 region.
2. Bit 1 at address 0x100h locks ESN2 region.
3. Bits 2-7 (“X”) are NOT programmable and will be ignored.
Document Number: 002-00650 Rev. *L
Page 42 of 60
S25FL032P
Figure 38. OTP Memory Map - Part 2
OT P R EGION
ADDRESS
0x2FFh
10 bytes (OTP31)
0x2F6h
0x2F5h
16 bytes (OTP30)
0x2E6h
0x2E5
16 bytes (OTP29)
0x2D6h
0x2D5h
16 bytes (OTP28)
0x2C6h
0x2C5h
16 bytes (OTP27)
n
0x2B6h
0x2B5h
es
ig
16 bytes (OTP26)
0x2A6h
0x2A5h
16 bytes (OTP25)
D
0x296h
0x295h
ew
16 bytes (OTP24)
rN
0x286h
0x285h
16 bytes (OTP23)
fo
0x276h
0x275h
en
d
16 bytes (OTP21)
ed
16 bytes (OTP22)
0x266h
0x265h
0x256h
0x255h
Address
0x214h
m
16 bytes (OTP20)
ec
om
0x246h
0x245h
16 bytes (OTP19)
0x236h
0x235h
0x226h
0x225h
R
16 bytes (OTP18)
ot
16 bytes (OTP17)
X
Bit 6 Bit 5 Bit 4 Bit 3 Bit 2 Bit 1 Bit 0
Bit 7 Bit 6 Bit 5 Bit 4 Bit 3 Bit 2 Bit 1 Bit 0
N
0x216h
0x215h
0x214h
0x215h
B it
0
1
2
3
4
5
6
7
0
1
2
3
4
5
6
7
Locks Region…
OTP17
OTP18
OTP19
OTP20
OTP21
OTP22
OTP23
OTP24
OTP25
OTP26
OTP27
OTP28
OTP29
OTP30
OTP31
R eserved
Note
1. Bit 7 (“X”) at address 0x215h is NOT programmable and will be ignored.
Document Number: 002-00650 Rev. *L
Page 43 of 60
S25FL032P
11. Power-up and Power-down
During power-up and power-down, certain conditions must be observed. CS# must follow the voltage applied on VCC, and must not
be driven low to select the device until VCC reaches the allowable values as follows (see Figure 39 and Table 20 on page 45):
At power-up, VCC (min.) plus a period of tPU
At power-down, GND
A pull-up resistor on Chip Select (CS#) typically meets proper power-up and power-down requirements.
No Read, Write Registers, program, or erase command should be sent to the device until VCC rises to the VCC min., plus a delay of
tPU. At power-up, the device is in standby mode (not Deep Power-Down mode) and the WEL bit is reset (0).
Each device in the host system should have the VCC rail decoupled by a suitable capacitor close to the package pins (this capacitor
is generally of the order of 0.1 µF), as a precaution to stabilizing the VCC feed.
es
ig
n
When VCC drops from the operating voltage to below the minimum VCC threshold at power-down, all operations are disabled and the
device does not respond to any commands. Note that data corruption may result if a power-down occurs while a Write Registers,
program, or erase operation is in progress.
Figure 39. Power-Up Timing Diagram
ew
D
Vcc
(max)
fo
rN
Vcc
(min)
ed
Vcc
Full Device Access
ec
om
m
en
d
t PU
N
ot
R
Time
Figure 40. Power-Down and Voltage Drop
Vcc
VCC (max)
No Device Access Allowed
VCC (min)
tPU
VCC (cut-off)
Device Access
Allowed
VCC (low)
tPD
Time
Document Number: 002-00650 Rev. *L
Page 44 of 60
S25FL032P
Table 20. Power-Up / Power-Down Voltage and Timing
Symbol
VCC(min)
VCC(cut-off)
VCC(low)
Parameter
Min
Max
Unit
VCC (minimum operation voltage)
2.7
V
VCC (Cut off where re-initialization is needed)
2.4
V
VCC (Low voltage for initialization to occur at read/standby)
VCC (Low voltage for initialization to occur at embedded)
0.2
2.3
V
tPU
VCC(min.) to device operation
tPD
VCC (low duration time)
300
µs
1.0
µs
12. Initial Delivery State
es
ig
n
The device is delivered with the memory array erased, that is, all bits are set to 1 (FFh) upon initial factory shipment. The Status
Register and Configuration Register contains 00h (all bits are set to 0).
D
13. Program Acceleration via W#/ACC Pin
rN
ew
The program acceleration function requires applying VHH to the W#/ACC input, and then waiting a period of tWC. Minimum tVHH rise
and fall times is required for W#/ACC to change to VHH from VIL or VIH. Removing VHH from the W#/ACC pin returns the device to
normal operation after a period of tWC.
fo
Figure 41. ACC Program Acceleration Timing Requirements
tWC
VIL or VIH
ec
om
tVHH
m
ACC
en
d
ed
VHH
tWC
VIL or VIH
Command OK
tVHH
ot
R
Note
Only Read Status Register (RDSR) and Page Program (PP) operation are allow when ACC is at (VHH).
The W#/ACC pin is disabled during Quad I/O mode.
Symbol
N
Table 21. ACC Program Acceleration Specifications
Parameter
Min.
Max
Unit
9.5
V
VHH
ACC Pin Voltage High
8.5
tVHH
ACC Voltage Rise and Fall time
2.2
µs
tWC
ACC at VHH and VIL or VIH to First command
5
µs
Document Number: 002-00650 Rev. *L
Page 45 of 60
S25FL032P
14. Electrical Specifications
14.1
Absolute Maximum Ratings
Description
Rating
65 °C to +150 °C
0.5 V to VCC+0.5 V
Ambient Storage Temperature
Voltage with Respect to Ground: All Inputs and I/Os
Output Short Circuit Current (Note 2)
200 mA
Notes
1. Minimum DC voltage on input or I/Os is -0.5 V. During voltage transitions, inputs or I/Os may undershoot GND to -2.0 V for periods of up to 20 ns. See Figure 42.
Maximum DC voltage on input or I/Os is VCC + 0.5 V. During voltage transitions inputs or I/Os may overshoot to VCC + 2.0 V for periods up to 20 ns. See Figure 43.
2. No more than one output may be shorted to ground at a time. Duration of the short circuit should not be greater than one second.
es
ig
n
3. Stresses above those listed under “Absolute Maximum Ratings” may cause permanent damage to the device. This is a stress rating only; functional operation of the
device at these or any other conditions above those indicated in the operational sections of this data sheet is not implied. Exposure of the device to absolute maximum
rating conditions for extended periods may affect device reliability.
D
Figure 42. Maximum Negative Overshoot Waveform
20 ns
ew
20 ns
rN
+0.8V
fo
–0.5V
ed
–2.0V
en
d
20 ns
m
Figure 43. Maximum Positive Overshoot Waveform
ec
om
20 ns
VCC
+2.0V
R
VCC
+0.5V
N
ot
2.0V
Document Number: 002-00650 Rev. *L
20 ns
20 ns
Page 46 of 60
S25FL032P
15. Operating Ranges
Table 22. Operating Ranges
Description
Rating
Ambient Operating Temperature (TA)
Positive Power Supply
Industrial
–40 °C to +85 °C
Automotive In-Cabin
–40 °C to +105 °C
Voltage Range
2.7 V to 3.6 V
Note
Operating ranges define those limits between which functionality of the device is guaranteed.
n
16. DC Characteristics
es
ig
This section summarizes the DC Characteristics of the device. Designers should check that the operating conditions in their circuit
match the measurement conditions specified in the Test Specifications in Table 24 on page 48, when relying on the quoted
parameters.
Supply voltage
VHH
ACC Program Acceleration
Voltage
VIL
Input Low Voltage**
**
VCC = 2.7 V to 3.6 V
Input High Voltage
Output Low Voltage
IOL = 1.6 mA, VCC = VCC min.
VOH
Output High Voltage
en
d
VIH
VOL
m
ed
VCC
ew
Test Conditions
rN
Parameter
fo
Symbol
D
Table 23. DC Characteristics (CMOS Compatible)
Input Leakage Current
ILO
Output Leakage Current
ot
R
ILI
ec
om
IOH = -0.1 mA
Min.
Limits
Typ*
Max
Unit
2.7
3.6
V
8.5
9.5
V
–0.3
0.3 x VCC
V
0.7 x VCC
VCC +0.5
V
0.4
V
VCC-0.6
V
VCC = VCC Max,
VIN = VCC or GND
2
µA
VCC = VCC Max,
VIN = VCC or GND
2
µA
At 80 MHz
(Dual or Quad)
38
At 104 MHz (Serial)
25
At 40 MHz (Serial)
12
ICC2
Active Power Supply Current
(Page Program)
CS# = VCC
26
mA
ICC3
Active Power Supply Current
(WRR)
CS# = VCC
15
mA
ICC4
Active Power Supply Current (SE)
CS# = VCC
26
mA
ICC5
Active Power Supply Current (BE)
CS# = VCC
26
mA
ISB1
Standby Current
CS# = VCC;
SO + VIN = GND or VCC
80
200
µA
IPD
Deep Power-down Current
CS# = VCC;
SO + VIN = GND or VCC
3
10
µA
N
ICC1
Active Power Supply Current READ (SO = Open)
mA
*Typical values are at TAI = 25 °C and VCC = 3 V
Document Number: 002-00650 Rev. *L
Page 47 of 60
S25FL032P
17. Test Conditions
Figure 44. AC Measurements I/O Waveform
0.8 VCC
0.7 VCC
0.5 VCC
0.3 VCC
Input Levels
0.2 VCC
Input and Output
Timing Reference levels
Table 24. Test Specifications
Parameter
CL
Load Capacitance
Min
Max
30
n
Symbol
Input Pulse Voltage
D
Input Timing Reference Voltage
5
ns
V
0.3 VCC to 0.7 VCC
V
0.5 VCC
V
N
ot
R
ec
om
m
en
d
ed
fo
rN
ew
Output Timing Reference Voltage
pF
0.2 VCC to 0.8 VCC
es
ig
Input Rise and Fall Times
Unit
Document Number: 002-00650 Rev. *L
Page 48 of 60
S25FL032P
18. AC Characteristics
Table 25. AC Characteristics
Symbol (Notes)
Min.
(Notes)
Parameter (Notes)
Typ (Notes)
Max (Notes)
Unit
MHz
SCK Clock Frequency for READ command
DC
40
SCK Clock Frequency for RDID command
DC
50
SCK Clock Frequency for all others:
FAST_READ, PP, QPP, P4E, P8E, SE, BE, DP,
RES, WREN, WRDI, RDSR, WRR, READ_ID
DC
104 (serial)
80 (dual/quad)
tWH, tCH
Clock High Time (5)
4.5
ns
tWL, tCL
Clock Low Time (5)
4.5
ns
tCRT, tCLCH
Clock Rise Time (slew rate)
0.1
V/ns
tCFT, tCHCL
Clock Fall Time (slew rate)
0.1
tCS
CS# High Time (Read Instructions)
CS# High Time (Program/Erase)
10
50
tCSS
CS# Active Setup Time
(relative to SCK)
3
ns
tCSH
CS# Active Hold Time
(relative to SCK)
3
ns
3
ns
Data in Setup Time
tHD:DAT
Data in Hold Time
R
Output Hold Time
tDIS
Output Disable Time
N
n
es
ig
ns
9.5 (Dual/Quad)
0
6.5 (Serial)
7 (Dual/Quad)
2
8 (Dual/Quad)
ns
ns
ot
tHO
ns
D
m
Clock Low to Output Valid
V/ns
8 (Serial)
ec
om
tV
MHz
ew
2
en
d
ed
tSU:DAT
rN
fC
fo
fR
8
ns
tHLCH
HOLD# Active Setup Time
(relative to SCK)
3
ns
tCHHH
HOLD# Active Hold Time
(relative to SCK)
3
ns
tHHCH
HOLD# Non Active Setup Time
(relative to SCK)
3
ns
tCHHL
HOLD# Non Active Hold Time
(relative to SCK)
3
ns
tHZ
HOLD# enable to Output Invalid
tLZ
HOLD# disable to Output Valid
8
8
ns
ns
tWPS
W#/ACC Setup Time (4)
20
ns
tWPH
W#/ACC Hold Time (4)
100
ns
tW
WRR Cycle Time
tPP
Page Programming (1)(2)
tEP
Page Programming (ACC = 9 V) (1)(2)(3)
Document Number: 002-00650 Rev. *L
50
ms
1.5
3
ms
1.2
2.4
ms
Page 49 of 60
S25FL032P
Table 25. AC Characteristics (Continued)
Symbol (Notes)
Min.
(Notes)
Parameter (Notes)
Typ (Notes)
Max (Notes)
Unit
tSE
Sector Erase Time (64 KB) (1)(2)
0.5
2
sec
tPE
Parameter Sector Erase Time (1)(2)
(4 KB or 8 KB)
200
800
ms
32
tBE
Bulk Erase Time (1)(2)
64
sec
tRES
Deep Power-down to Standby Mode
30
µs
tDP
Time to enter Deep Power-down Mode
10
µs
tVHH
ACC Voltage Rise and Fall time
tWC
ACC at VHH and VIL or VIH to first command
2.2
µs
5
µs
es
ig
n
Notes
1. Typical program and erase times assume the following conditions: 25°C, VCC = 3.0 V; 10,000 cycles; checkerboard data pattern.
2. Under worst-case conditions of 85°C; VCC = 2.7 V; 100,000 cycles.
3. Acceleration mode (9 V ACC) only in Program mode, not Erase.
D
4. Only applicable as a constraint for WRR instruction when SRWD is set to a ‘1’.
5. tWH + tWL must be less than or equal to 1/fC.
6.
Full Vcc range (2.7 – 3.6 V) & CL = 30 pF.
ew
rN
fo
Capacitance
Parameter
CIN
Input Capacitance
(applies to SCK, PO7-PO0, SI, CS#)
COUT
Test Conditions
Output Capacitance
(applies to PO7-PO0, SO)
Typ
Max
Unit
VOUT = 0 V
9.0
12.0
pF
VIN = 0 V
12.0
16.0
pF
R
Notes
1. Sampled, not 100% tested.
2. Test conditions TA = 25°C, f = 1.0 MHz.
Min
en
d
Symbol
ed
18.1
m
8.
Regulated Vcc range (3.0 – 3.6 V) & CL = 30 pF.
Regulated Vcc range (3.0 – 3.6 V) & CL = 15 pF.
ec
om
7.
ot
3. For more information on pin capacitance, please consult the IBIS models.
N
Figure 45. SPI Mode 0 (0,0) Input Timing
tCS
CS#
tCSH
tCSS
tCSH
tCSS
SCK
tSU:DAT tHD:DAT
SI
MSB IN
SO
tCFT
tCRT
LSB IN
Hi-Z
Document Number: 002-00650 Rev. *L
Page 50 of 60
S25FL032P
Figure 46. SPI Mode 0 (0,0) Output Timing
CS#
tWH
SCK
tV
tWL
tV
tHO
tDIS
tHO
SO
LSB OUT
n
Figure 47. HOLD# Timing
tHHCH
tHLCH
D
tCHHL
es
ig
CS#
ew
SCK
tHZ
tLZ
en
d
ed
fo
SO
rN
tCHHH
ec
om
m
SI
ot
R
HOLD#
N
Figure 48. Write Protect Setup and Hold Timing during WRR when SRWD = 1
W#
tWPS
tWPH
CS#
SCK
SI
SO
Hi-Z
Document Number: 002-00650 Rev. *L
Page 51 of 60
S25FL032P
19. Physical Dimensions
SOC008 wide — 8-pin Plastic Small Outline Package (208-mils Body Width)
en
d
ed
fo
rN
ew
D
es
ig
n
19.1
NOTES:
MAX.
ec
om
1.75
NOM.
-
2.16
-
0.25
-
1.90
-
0.48
0.05
A2
1.70
b
0.36
b1
0.33
-
0.46
c
0.19
-
0.24
0.15
-
0.20
D
N
c1
ot
A1
R
A
MIN.
m
DIMENSIONS
SYMBOL
5.28 BSC
E
8.00 BSC
E1
5.28 BSC
e
L
1.27 BSC
-
0.51
L1
1.36 REF
L2
0.25 BSC
0.76
8
N
0
0°
-
8°
01
5°
-
15°
02
Document Number: 002-00650 Rev. *L
0-8° REF
1. ALL DIMENSIONS ARE IN MILLIMETERS.
2. DIMENSIONING AND TOLERANCING PER ASME Y14.5M - 1994.
3. DIMENSION D DOES NOT INCLUDE MOLD FLASH, PROTRUSIONS OR GATE BURRS.
MOLD FLASH, PROTRUSIONS OR GATE BURRS SHALL NOT EXCEED 0.15 mm PER
END. DIMENSION E1 DOES NOT INCLUDE INTERLEAD FLASH OR PROTRUSION.
INTERLEAD FLASH OR PROTRUSION SHALL NOT EXCEED 0.25 mm PER SIDE.
D AND E1 DIMENSIONS ARE DETERMINED AT DATUM H.
4. THE PACKAGE TOP MAY BE SMALLER THAN THE PACKAGE BOTTOM. DIMENSIONS
D AND E1 ARE DETERMINED AT THE OUTMOST EXTREMES OF THE PLASTIC BODY
EXCLUSIVE OF MOLD FLASH, TIE BAR BURRS, GATE BURRS AND INTERLEAD
FLASH, BUT INCLUSIVE OF ANY MISMATCH BETWEEN THE TOP AND BOTTOM OF
THE PLASTIC BODY.
5. DATUMS A AND B TO BE DETERMINED AT DATUM H.
6. "N" IS THE MAXIMUM NUMBER OF TERMINAL POSITIONS FOR THE SPECIFIED
PACKAGE LENGTH.
7. THE DIMENSIONS APPLY TO THE FLAT SECTION OF THE LEAD BETWEEN 0.10 TO
0.25 mm FROM THE LEAD TIP.
8. DIMENSION "b" DOES NOT INCLUDE DAMBAR PROTRUSION. ALLOWABLE DAMBAR
PROTRUSION SHALL BE 0.10 mm TOTAL IN EXCESS OF THE "b" DIMENSION AT
MAXIMUM MATERIAL CONDITION. THE DAMBAR CANNOT BE LOCATED ON THE
LOWER RADIUS OF THE LEAD FOOT.
9. THIS CHAMFER FEATURE IS OPTIONAL. IF IT IS NOT PRESENT, THEN A PIN 1
IDENTIFIER MUST BE LOCATED WITHIN THE INDEX AREA INDICATED.
10. LEAD COPLANARITY SHALL BE WITHIN 0.10 mm AS MEASURED FROM THE
SEATING PLANE.
002-15548 **
Page 52 of 60
S25FL032P
19.2
SO3 016 — 16-pin Wide Plastic Small Outline Package (300-mils Body Width)
0.20 C A-B
0.10 C D
2X
0.33 C
0.25 M
C A-B D
0.10 C
ed
fo
rN
ew
D
es
ig
n
0.10 C
DIMENSIONS
NOTES:
NOM.
MAX.
1. ALL DIMENSIONS ARE IN MILLIMETERS.
2.35
-
2.65
A1
0.10
-
0.30
A2
2.05
b
0.31
b1
c
0.27
c1
0.20
D
ec
om
2.55
0.51
0.48
-
0.33
-
0.30
R
-
10.30 BSC
10.30 BSC
7.50 BSC
e
L
-
N
E
E1
-
8. DIMENSION "b" DOES NOT INCLUDE DAMBAR PROTRUSION. ALLOWABLE DAMBAR
PROTRUSION SHALL BE 0.10 mm TOTAL IN EXCESS OF THE "b" DIMENSION AT
1.27 BSC
-
0.40
L1
1.40 REF
L2
0.25 BSC
1.27
16
N
h
0.25
-
0
0°
-
8°
01
5°
-
15°
02
0°
-
-
Document Number: 002-00650 Rev. *L
2. DIMENSIONING AND TOLERANCING PER ASME Y14.5M - 1994.
3. DIMENSION D DOES NOT INCLUDE MOLD FLASH, PROTRUSIONS OR GATE BURRS.
MOLD FLASH, PROTRUSIONS OR GATE BURRS SHALL NOT EXCEED 0.15 mm PER
END. DIMENSION E1 DOES NOT INCLUDE INTERLEAD FLASH OR PROTRUSION.
INTERLEAD FLASH OR PROTRUSION SHALL NOT EXCEED 0.25 mm PER SIDE.
D AND E1 DIMENSIONS ARE DETERMINED AT DATUM H.
4. THE PACKAGE TOP MAY BE SMALLER THAN THE PACKAGE BOTTOM. DIMENSIONS
D AND E1 ARE DETERMINED AT THE OUTMOST EXTREMES OF THE PLASTIC BODY
EXCLUSIVE OF MOLD FLASH, TIE BAR BURRS, GATE BURRS AND INTERLEAD
FLASH, BUT INCLUSIVE OF ANY MISMATCH BETWEEN THE TOP AND BOTTOM OF
THE PLASTIC BODY.
5. DATUMS A AND B TO BE DETERMINED AT DATUM H.
6. "N" IS THE MAXIMUM NUMBER OF TERMINAL POSITIONS FOR THE SPECIFIED
PACKAGE LENGTH.
7. THE DIMENSIONS APPLY TO THE FLAT SECTION OF THE LEAD BETWEEN 0.10 TO
0.25 mm FROM THE LEAD TIP.
m
A
0.20
en
d
MIN.
ot
SYMBOL
MAXIMUM MATERIAL CONDITION. THE DAMBAR CANNOT BE LOCATED ON THE
LOWER RADIUS OF THE LEAD FOOT.
9. THIS CHAMFER FEATURE IS OPTIONAL. IF IT IS NOT PRESENT, THEN A PIN 1
IDENTIFIER MUST BE LOCATED WITHIN THE INDEX AREA INDICATED.
10. LEAD COPLANARITY SHALL BE WITHIN 0.10 mm AS MEASURED FROM THE
SEATING PLANE.
0.75
002-15547 *A
Page 53 of 60
S25FL032P
UNE008 — USON 8-contact (5 × 6 mm) No-Lead Package
ec
om
m
en
d
ed
fo
rN
ew
D
es
ig
n
19.3
MIN.
e
NOM.
MAX.
ot
1.27 BSC.
8
N
N
ND
L
R
DIMENSIONS
SYMBOL
4
0.55
0.60
NOTES:
1.
DIMENSIONING AND TOLERANCING CONFORMS TO ASME Y14.5M-1994.
2.
ALL DIMENSIONS ARE IN MILLIMETERS.
3.
4
DIMENSION "b" APPLIES TO METALLIZED TERMINAL AND IS MEASURED
N IS THE TOTAL NUMBER OF TERMINALS.
BETWEEN 0.15 AND 0.30mm FROM TERMINAL TIP. IF THE TERMINAL HAS
0.65
THE OPTIONAL RADIUS ON THE OTHER END OF THE TERMINAL, THE
b
0.35
0.40
0.45
D2
3.90
4.00
4.10
5
ND REFERS TO THE NUMBER OF TERMINALS ON D SIDE.
E2
3.30
3.40
3.50
MAX. PACKAGE WARPAGE IS 0.05mm.
PIN #1 ID ON TOP WILL BE LOCATED WITHIN THE INDICATED ZONE.
DIMENSION "b" SHOULD NOT BE MEASURED IN THAT RADIUS AREA.
D
5.00 BSC
6.
7.
E
6.00 BSC
0.50
0.02
8
9
A
A1
0.45
0.00
A3
0.20 REF
K
0.20 MIN.
Document Number: 002-00650 Rev. *L
0.55
0.05
MAXIMUM ALLOWABLE BURR IS 0.076mm IN ALL DIRECTIONS.
BILATERAL COPLANARITY ZONE APPLIES TO THE EXPOSED HEAT SINK
SLUG AS WELL AS THE TERMINALS.
002-18903 **
Page 54 of 60
S25FL032P
WNF008 — WSON 8-contact (6 × 8 mm) No-Lead Package
ec
om
m
en
d
ed
fo
rN
ew
D
es
ig
n
19.4
e
MAX.
1.27 BSC.
8
N
N
ND
L
NOM.
ot
MIN.
R
DIMENSIONS
SYMBOL
0.45
4
0.50
NOTES:
1.
DIMENSIONING AND TOLERANCING CONFORMS TO ASME Y14.5M-1994.
2.
ALL DIMENSIONS ARE IN MILLIMETERS.
3.
4
DIMENSION "b" APPLIES TO METALLIZED TERMINAL AND IS MEASURED
N IS THE TOTAL NUMBER OF TERMINALS.
BETWEEN 0.15 AND 0.30mm FROM TERMINAL TIP. IF THE TERMINAL HAS
0.55
THE OPTIONAL RADIUS ON THE OTHER END OF THE TERMINAL, THE
b
0.35
0.40
0.45
D2
4.70
4.80
4.90
5
ND REFERS TO THE NUMBER OF TERMINALS ON D SIDE.
E2
5.70
5.80
5.90
6.
7.
MAX. PACKAGE WARPAGE IS 0.05mm.
8
9
PIN #1 ID ON TOP WILL BE LOCATED WITHIN THE INDICATED ZONE.
D
6.00 BSC
E
8.00 BSC
0.75
0.02
0.20 MIN.
0.80
0.05
-
0.15
A
A1
0.70
0.00
K
L1
0.00
DIMENSION "b" SHOULD NOT BE MEASURED IN THAT RADIUS AREA.
MAXIMUM ALLOWABLE BURR IS 0.076mm IN ALL DIRECTIONS.
BILATERAL COPLANARITY ZONE APPLIES TO THE EXPOSED HEAT SINK
SLUG AS WELL AS THE TERMINALS.
10
A MAXIMUM 0.15mm PULL BACK (L1) MAY BE PRESENT.
002-18902 **
Document Number: 002-00650 Rev. *L
Page 55 of 60
S25FL032P
FAB024 — 24-ball Ball Grid Array (6 x 8 mm) Package
ed
fo
rN
ew
D
es
ig
n
19.5
NOTES:
-
A1
0.20
MAX.
-
1.20
-
-
D
8.00 BSC
6.00 BSC
4.00 BSC
E1
4.00 BSC
MD
5
ME
5
N
R
E
D1
ot
0.40
N
eE
0.35
DIMENSIONING AND TOLERANCING METHODS PER ASME Y14.5M-1994.
2.
ALL DIMENSIONS ARE IN MILLIMETERS.
3.
BALL POSITION DESIGNATION PER JEP95, SECTION 3, SPP-020.
4.
e REPRESENTS THE SOLDER BALL GRID PITCH.
5.
SYMBOL "MD" IS THE BALL MATRIX SIZE IN THE "D" DIRECTION.
1.00 BSC
SYMBOL "ME" IS THE BALL MATRIX SIZE IN THE "E" DIRECTION.
N IS THE NUMBER OF POPULATED SOLDER BALL POSITIONS FOR MATRIX SIZE MD X ME.
6
24
b
1.
m
A
NOM.
ec
om
MIN.
en
d
DIMENSIONS
SYMBOL
DIMENSION "b" IS MEASURED AT THE MAXIMUM BALL DIAMETER IN A PLANE
PARALLEL TO DATUM C.
0.45
7
"SD" AND "SE" ARE MEASURED WITH RESPECT TO DATUMS A AND B AND DEFINE THE
eD
1.00 BSC
POSITION OF THE CENTER SOLDER BALL IN THE OUTER ROW.
SD
0.00 BSC
WHEN THERE IS AN ODD NUMBER OF SOLDER BALLS IN THE OUTER ROW, "SD" OR "SE" = 0.
SE
0.00 BSC
WHEN THERE IS AN EVEN NUMBER OF SOLDER BALLS IN THE OUTER ROW, "SD" = eD/2 AND
"SE" = eE/2.
8.
"+" INDICATES THE THEORETICAL CENTER OF DEPOPULATED BALLS.
9.
A1 CORNER TO BE IDENTIFIED BY CHAMFER, LASER OR INK MARK,
METALLIZED MARK INDENTATION OR OTHER MEANS.
002-15534 **
Document Number: 002-00650 Rev. *L
Page 56 of 60
S25FL032P
FAC024 — 24-ball Ball Grid Array (6 x 8 mm) Package
MAX.
-
-
1.20
A1
0.25
-
-
D
8.00 BSC
E
6.00 BSC
D1
5.00 BSC
3.00 BSC
6
ME
4
ot
N
R
E1
MD
1.
2.
m
MIN.
ec
om
NOM.
A
en
d
NOTES:
DIMENSIONS
SYMBOL
0.40
N
eE
0.35
1.00 BSC
DIMENSIONING AND TOLERANCING METHODS PER ASME Y14.5M-1994.
ALL DIMENSIONS ARE IN MILLIMETERS.
3.
BALL POSITION DESIGNATION PER JEP95, SECTION 3, SPP-020.
4.
e
5.
SYMBOL "MD" IS THE BALL MATRIX SIZE IN THE "D" DIRECTION.
REPRESENTS THE SOLDER BALL GRID PITCH.
SYMBOL "ME" IS THE BALL MATRIX SIZE IN THE "E" DIRECTION.
N IS THE NUMBER OF POPULATED SOLDER BALL POSITIONS FOR MATRIX SIZE MD X ME.
6
24
b
ed
fo
rN
ew
D
es
ig
n
19.6
DIMENSION "b" IS MEASURED AT THE MAXIMUM BALL DIAMETER IN A PLANE
PARALLEL TO DATUM C.
0.45
7
"SD" AND "SE" ARE MEASURED WITH RESPECT TO DATUMS A AND B AND DEFINE THE
POSITION OF THE CENTER SOLDER BALL IN THE OUTER ROW.
eD
1.00 BSC
SD
0.50 BSC
WHEN THERE IS AN ODD NUMBER OF SOLDER BALLS IN THE OUTER ROW, "SD" OR "SE" = 0.
SE
0.50 BSC
WHEN THERE IS AN EVEN NUMBER OF SOLDER BALLS IN THE OUTER ROW, "SD" = eD/2 AND
"SE" = eE/2.
8.
"+" INDICATES THE THEORETICAL CENTER OF DEPOPULATED BALLS.
9.
A1 CORNER TO BE IDENTIFIED BY CHAMFER, LASER OR INK MARK,
METALLIZED MARK INDENTATION OR OTHER MEANS.
002-15535 **
Document Number: 002-00650 Rev. *L
Page 57 of 60
S25FL032P
20. Revision History
Document History Page
Document Title: S25FL032P, 32-Mbit 3.0 V Flash Memory
Document Number: 002-00650
Rev.
ECN No.
Orig. of
Change
Submission
Date
**
BWHA
06/09/2008 Initial release
BWHA
Connection Diagrams: Added USON package
Valid Combinations Table: Added Tray packing type
Configuration Register: Added OTP description for BPNV bit
Configuration Register Table: Corrected TBPARM description. Added “Default”
setting information upon initial factory shipment.
Instruction Set: Separated Mode bit and Dummy bytes
Product Group CFI Primary Vendor-Specific Extended Query: Corrected data
of 45h bytes
Read-ID (READ_ID): Removed statement of 8-cycle buffer for Manufacturer
ID and the Device ID
Read Status Register: Corrected description for SRWD bit in the Status
02/12/2009 Register Table. Modified E_ERR and P_ERR descriptions
Read Configuration Register: Updated figure
Parameter Sector Erase (P4E, P8E): Updated figure
Release from Deep Power-Down and Read Electronic Signature (RES):
Updated figure
OTP Regions: Modified description for the ACC function
Power-up and Power-down: Changed specification for tPU
Absolute Maximum Ratings: Corrected the Table
DC Characteristics: Changed maximum specifications for ICC1 and ICC3.
Modified Test Conditions for ISB1 and IPD
AC Characteristics: Changed maximum specifications for tW. Added note for
max values assume 100k cycles. Changed Clock High/Low time.
BWHA
Connection Diagrams: Corrected package name
Dual Output Read Mode (DOR): Added statement for Dual Output Read
command
Quad Output Read Mode (QOR): Added statement for Quad Output Read
command
05/26/2009
Power Up & Power Down: Updated VCC(low) Min in Table: Power-Up /
Power-Down Voltage and Timing
AC Characteristics: Updated tWH, tCH and tWL, tCL
Revision History: Corrected “Revision 02 (February 12, 2009)” for AC
Characteristics
ew
R
N
ot
*B
ec
om
m
en
d
ed
fo
rN
*A
D
es
ig
n
Description of Change
*C
BWHA
Document Number: 002-00650 Rev. *L
Distinctive Characteristics: Added BGA package information
Connection Diagrams: Added BGA package
Ordering Information: Added Automotive In-cabin information. Added BGA
package information.
Valid Combinations: Corrected Valid Combinations Table
Configuration Register: Added Suggested Cross Settings Table
Accelerated Programming Operation: Added note for ACC function
07/22/2009
Read Identification (RDID): Updated Read Identification description. Updated
figure for RDID. Updated CFI table for 29h.
Write Registers (WRR): Added note for HPM
Parameter Sector Erase (P4E, P8E): Updated description for P4E/P8E
command.
Sector Erase (SE): Updated description for SE command
Release from Deep Power-Down (RES): Added note for RES command
Page 58 of 60
S25FL032P
Document History Page (Continued)
Document Title: S25FL032P, 32-Mbit 3.0 V Flash Memory
Document Number: 002-00650
Rev.
Orig. of
Change
Submission
Date
Description of Change
BWHA
Operating Ranges: Updated descriptions. Added ESN1 and ESN2 Table.
AC Characteristics: Added Automotive In-cabin spec for fC. Updated tWH, tCH
07/22/2009
and tWL, tCL.
Physical Dimensions: Added BGA 6 x 8 mm package
BWHA
Global: Changed all references to RDID clock rate from 40 to 50 MHz
Connection Diagrams: Added “5 x 5 pin configuration” to Figure 2.5 title.
Added 6 x 4 pin configuration BGA connection diagram. Added note regarding
exposed central pad on bottom of package to the WSON and USON
connection diagram.
Ordering Information: Added Automotive In-Cabin temperature valid
combinations for BGA packages. Added 02 and 03 model numbers for BGA
10/05/2009 packages. Removed BGA from 00 model number description. Added
Low-Halogen material option.
Valid Combinations: Changed valid BGA model number combinations to 02
and 03. Changed valid BGA material option to Low-Halogen.
Removed Note 1.
Physical Dimensions: Added FAC024 BGA package
AC Characteristics: Removed 76 MHz Automotive in-cabin spec from fC and
Note 9.
fo
rN
ew
D
*D
es
ig
n
*C (Cont.)
ECN No.
BWHA
*F
BWHA
09/21/2012 AC Characteristics: Changed Output Hold Time (tHO) to 2 ns (min).
ec
om
m
en
d
ed
*E
Instruction Set Table: Updated QIOR command
Power-Up / Power-Down Voltage and Timing Table: Updated tPU (max)
Initial Delivery State: Modified section
12/07/2011
Capacitance: Added notes to table
Physical Dimensions: Updated the package outline drawing for SOIC, WSON,
USON, and BGA 5x5 packages.
Command Definitions: Instruction Set table: Corrected the value of CLSR
command
10/30/2012 Write Registers (WRR): Protection Modes table: Added Parameter Sector
Erase to Memory Content columns for clarification
Parameter Sector Erase (P4E, P8E): Updated the table reference.
BWHA
*H
BWHA
01/29/2013
*I
4904072
BWHA
09/18/2015 Updated to Cypress template.
*J
5615358
ECAO
03/24/2017
N
ot
R
*G
Capacitance: Added “Typical” values column. Corrected “Max” values for CIN /
COUT (Input / Output Capacitance).
Corrected tCFT and tCRT positions in Figure 45 on page 50.
Updated Cypress logo and Sales page.
*K
5711277
ECAO
Added Valid Automotive Ordering Combinations in Section 5.1, Valid
Combinations on page 9
04/25/2017
Updated all package outline drawings in Section 19., Physical Dimensions
on page 52
*L
5742306
ECAO
Added Valid Automotive Ordering Combinations in Section 5.1, Valid
05/19/2017 Combinations on page 9.
Added “Not Recommended for New Design (NRND)” status.
Document Number: 002-00650 Rev. *L
Page 59 of 60
S25FL032P
Sales, Solutions, and Legal Information
Worldwide Sales and Design Support
Cypress maintains a worldwide network of offices, solution centers, manufacturer’s representatives, and distributors. To find the office
closest to you, visit us at Cypress Locations.
PSoC® Solutions
Products
ARM® Cortex® Microcontrollers
cypress.com/arm
Automotive
PSoC 1 | PSoC 3 | PSoC 4 | PSoC 5LP | PSoC 6
cypress.com/automotive
Clocks & Buffers
Cypress Developer Community
cypress.com/clocks
Interface
Forums | WICED IOT Forums | Projects | Video | Blogs |
Training | Components
cypress.com/interface
Internet of Things
cypress.com/iot
Technical Support
cypress.com/memory
cypress.com/mcu
PSoC
cypress.com/psoc
Power Management ICs
cypress.com/support
n
Microcontrollers
es
ig
Memory
cypress.com/pmic
cypress.com/touch
cypress.com/usb
cypress.com/wireless
N
ot
R
ec
om
m
en
d
ed
fo
rN
Wireless Connectivity
ew
USB Controllers
D
Touch Sensing
© Cypress Semiconductor Corporation, 2008-2017. This document is the property of Cypress Semiconductor Corporation and its subsidiaries, including Spansion LLC ("Cypress"). This document,
including any software or firmware included or referenced in this document ("Software"), is owned by Cypress under the intellectual property laws and treaties of the United States and other countries
worldwide. Cypress reserves all rights under such laws and treaties and does not, except as specifically stated in this paragraph, grant any license under its patents, copyrights, trademarks, or other
intellectual property rights. If the Software is not accompanied by a license agreement and you do not otherwise have a written agreement with Cypress governing the use of the Software, then Cypress
hereby grants you a personal, non-exclusive, nontransferable license (without the right to sublicense) (1) under its copyright rights in the Software (a) for Software provided in source code form, to
modify and reproduce the Software solely for use with Cypress hardware products, only internally within your organization, and (b) to distribute the Software in binary code form externally to end users
(either directly or indirectly through resellers and distributors), solely for use on Cypress hardware product units, and (2) under those claims of Cypress's patents that are infringed by the Software (as
provided by Cypress, unmodified) to make, use, distribute, and import the Software solely for use with Cypress hardware products. Any other use, reproduction, modification, translation, or compilation
of the Software is prohibited.
TO THE EXTENT PERMITTED BY APPLICABLE LAW, CYPRESS MAKES NO WARRANTY OF ANY KIND, EXPRESS OR IMPLIED, WITH REGARD TO THIS DOCUMENT OR ANY SOFTWARE
OR ACCOMPANYING HARDWARE, INCLUDING, BUT NOT LIMITED TO, THE IMPLIED WARRANTIES OF MERCHANTABILITY AND FITNESS FOR A PARTICULAR PURPOSE. To the extent
permitted by applicable law, Cypress reserves the right to make changes to this document without further notice. Cypress does not assume any liability arising out of the application or use of any
product or circuit described in this document. Any information provided in this document, including any sample design information or programming code, is provided only for reference purposes. It is
the responsibility of the user of this document to properly design, program, and test the functionality and safety of any application made of this information and any resulting product. Cypress products
are not designed, intended, or authorized for use as critical components in systems designed or intended for the operation of weapons, weapons systems, nuclear installations, life-support devices or
systems, other medical devices or systems (including resuscitation equipment and surgical implants), pollution control or hazardous substances management, or other uses where the failure of the
device or system could cause personal injury, death, or property damage ("Unintended Uses"). A critical component is any component of a device or system whose failure to perform can be reasonably
expected to cause the failure of the device or system, or to affect its safety or effectiveness. Cypress is not liable, in whole or in part, and you shall and hereby do release Cypress from any claim,
damage, or other liability arising from or related to all Unintended Uses of Cypress products. You shall indemnify and hold Cypress harmless from and against all claims, costs, damages, and other
liabilities, including claims for personal injury or death, arising from or related to any Unintended Uses of Cypress products.
Cypress, the Cypress logo, Spansion, the Spansion logo, and combinations thereof, WICED, PSoC, CapSense, EZ-USB, F-RAM, and Traveo are trademarks or registered trademarks of Cypress in
the United States and other countries. For a more complete list of Cypress trademarks, visit cypress.com. Other names and brands may be claimed as property of their respective owners.
Document Number: 002-00650 Rev. *L
Revised May 19, 2017
Page 60 of 60