S34ML01G1
S34ML02G1, S34ML04G1
1 Gb, 2 Gb, 4 Gb, 3 V SLC
NAND Flash For Embedded
Distinctive Characteristics
Density
– 1 Gb/ 2 Gb / 4 Gb
NAND flash interface
– Open NAND Flash Interface (ONFI) 1.0 compliant
– Address, Data and Commands multiplexed
Architecture
– Input / Output Bus Width: 8-bits / 16-bits
– Page size:
Supply voltage
– 3.3-V device: Vcc = 2.7 V ~ 3.6 V
– x8 = 2112 (2048 + 64) bytes; 64 bytes is spare area
– x16 = 1056 (1024 + 32) words; 32 words is spare area
– Block size: 64 Pages
– x8 = 128 KB + 4 KB
– x16 = 64k + 2k words
Security
– One Time Programmable (OTP) area
– Hardware program/erase disabled during power transition
Additional features
– 2 Gb and 4 Gb parts support Multiplane Program and Erase
commands
– Supports Copy Back Program
– 2 Gb and 4 Gb parts support Multiplane Copy Back Program
– Supports Read Cache
– Plane size:
– 1 Gb / 2 Gb: 1024 Blocks per Plane
x8 = 128 MB + 4 MB
x16 = 64M + 2M words
– 4 Gb: 2048 Blocks per Plane
x8 = 256 MB+ 8 MB
x16 = 128M + 4M words
Electronic signature
– Manufacturer ID: 01h
Operating temperature
– Industrial: -40 °C to 85 °C
– Automotive: -40 °C to 105 °C
– Device size:
– 1 Gb: 1 Plane per Device or 128 MB
– 2 Gb: 2 Planes per Device or 256 MB
– 4 Gb: 2 Planes per Device or 512 MB
Performance
Page Read / Program
– Random access: 25 µs (Max)
– Sequential access: 25 ns (Min)
– Program time / Multiplane Program time: 200 µs (Typ)
Block Erase (S34ML01G1)
– Block Erase time: 2.0 ms (Typ)
Block Erase / Multiplane Erase (S34ML02G1, S34ML04G1)
– Block Erase time: 3.5 ms (Typ)
Reliability
– 100,000 Program / Erase cycles (Typ)
(with 1 bit ECC per 528 bytes (x8) or 264 words (x16))
– 10 Year Data retention (Typ)
– For one plane structure (1-Gb density)
– Block zero is valid and will be valid for at least 1,000 programerase cycles with ECC
– For two plane structures (2-Gb and 4-Gb densities)
– Blocks zero and one are valid and will be valid for at least
1,000 program-erase cycles with ECC
Package options
– Lead Free and Low Halogen
– 48-Pin TSOP 12 x 20 x 1.2 mm
– 63-Ball BGA 9 x 11 x 1 mm
Cypress Semiconductor Corporation
Document Number: 002-00676 Rev. *T
•
198 Champion Court
•
San Jose, CA 95134-1709
•
408-943-2600
Revised Tuesday, May 16, 2017
S34ML01G1
S34ML02G1, S34ML04G1
Contents
Distinctive Characteristics .................................................. 1
Performance.......................................................................... 1
1.
1.1
1.2
1.3
1.4
1.5
1.6
1.7
General Description..................................................... 4
Logic Diagram................................................................ 5
Connection Diagram ...................................................... 6
Pin Description............................................................... 7
Block Diagram................................................................ 8
Array Organization ......................................................... 9
Addressing ................................................................... 10
Mode Selection ............................................................ 13
2.
2.1
2.2
2.3
2.4
2.5
2.6
Bus Operation ............................................................
Command Input ...........................................................
Address Input...............................................................
Data Input ....................................................................
Data Output..................................................................
Write Protect ................................................................
Standby........................................................................
3.
3.1
3.2
3.3
3.4
3.5
3.6
3.16
3.17
3.18
3.19
3.20
Command Set............................................................. 15
Page Read ................................................................... 16
Page Program.............................................................. 16
Multiplane Program — S34ML02G1 and S34ML04G1 17
Page Reprogram — S34ML02G1 and S34ML04G1.... 18
Block Erase.................................................................. 19
Multiplane Block Erase — S34ML02G1 and S34ML04G1
20
Copy Back Program..................................................... 20
EDC Operation — S34ML02G1 and S34ML04G1....... 21
Read Status Register................................................... 23
Read Status Enhanced — S34ML02G1 and S34ML04G1
23
Read Status Register Field Definition .......................... 24
Reset............................................................................ 24
Read Cache ................................................................. 24
Cache Program............................................................ 25
Multiplane Cache Program — S34ML02G1 and
S34ML04G1................................................................. 26
Read ID........................................................................ 27
Read ID2...................................................................... 29
Read ONFI Signature .................................................. 29
Read Parameter Page ................................................. 30
One-Time Programmable (OTP) Entry ........................ 32
4.
4.1
4.2
4.3
Signal Descriptions ...................................................
Data Protection and Power On / Off Sequence ...........
Ready/Busy..................................................................
Write Protect Operation ...............................................
32
32
33
34
5.
5.1
5.2
5.3
5.4
5.5
5.6
Electrical Characteristics ..........................................
Valid Blocks .................................................................
Absolute Maximum Ratings .........................................
Recommended Operating Conditions..........................
AC Test Conditions ......................................................
AC Characteristics .......................................................
DC Characteristics .......................................................
35
35
35
35
35
36
37
3.7
3.8
3.9
3.10
3.11
3.12
3.13
3.14
3.15
Document Number: 002-00676 Rev. *T
13
13
13
14
14
14
14
5.7
5.8
Pin Capacitance............................................................ 37
Program / Erase Characteristics ................................... 38
6.
6.1
6.2
6.3
6.4
6.25
6.26
6.27
6.28
6.29
6.30
6.31
Timing Diagrams......................................................... 38
Command Latch Cycle.................................................. 38
Address Latch Cycle ..................................................... 39
Data Input Cycle Timing................................................ 39
Data Output Cycle Timing (CLE=L, WE#=H, ALE=L,
WP#=H) ........................................................................ 40
Data Output Cycle Timing (EDO Type, CLE=L, WE#=H,
ALE=L).......................................................................... 40
Page Read Operation ................................................... 41
Page Read Operation (Interrupted by CE#).................. 42
Page Read Operation Timing with CE# Don’t Care...... 43
Page Program Operation .............................................. 43
Page Program Operation Timing with CE# Don’t Care. 44
Page Program Operation with Random Data Input ...... 44
Random Data Output In a Page ................................... 45
Multiplane Page Program Operation — S34ML02G1 and
S34ML04G1.................................................................. 45
Block Erase Operation .................................................. 46
Multiplane Block Erase — S34ML02G1 and S34ML04G1
47
Copy Back Read with Optional Data Readout .............. 48
Copy Back Program Operation With Random Data Input..
48
Multiplane Copy Back Program — S34ML02G1 and
S34ML04G1.................................................................. 49
Read Status Register Timing ........................................ 50
Read Status Enhanced Timing ..................................... 51
Reset Operation Timing ................................................ 51
Read Cache .................................................................. 52
Cache Program............................................................. 54
Multiplane Cache Program — S34ML02G1 and
S34ML04G1.................................................................. 55
Read ID Operation Timing ............................................ 57
Read ID2 Operation Timing .......................................... 57
Read ONFI Signature Timing........................................ 58
Read Parameter Page Timing ...................................... 58
OTP Entry Timing ......................................................... 59
Power On and Data Protection Timing ......................... 59
WP# Handling............................................................... 60
7.
7.1
Physical Interface ....................................................... 61
Physical Diagram .......................................................... 61
8.
System Interface ......................................................... 63
9.
9.1
9.2
Error Management ...................................................... 65
System Bad Block Replacement................................... 65
Bad Block Management................................................ 66
10.
Ordering Information .................................................. 67
11.
Document History Page ............................................. 68
6.5
6.6
6.7
6.8
6.9
6.10
6.11
6.12
6.13
6.14
6.15
6.16
6.17
6.18
6.19
6.20
6.21
6.22
6.23
6.24
Page 2 of 73
S34ML01G1
S34ML02G1, S34ML04G1
1. General Description
The Cypress S34ML01G1, S34ML02G1, and S34ML04G1 series is offered with a 3.3-V VCC power supply, and with ×8 or ×16 I/O
interface. Its NAND cell provides the most cost-effective solution for the solid state mass storage market. The memory is divided into
blocks that can be erased independently so it is possible to preserve valid data while old data is erased. The page size for ×8 is
(2048 + 64 spare) bytes; for ×16 (1024 + 32) words.
Each block can be programmed and erased up to 100,000 cycles with ECC (error correction code) on. To extend the lifetime of
NAND flash devices, the implementation of an ECC is mandatory.
The chip supports CE# don't care function. This function allows the direct download of the code from the NAND flash memory device
by a microcontroller, since the CE# transitions do not stop the read operation.
The devices have a Read Cache feature that improves the read throughput for large files. During cache reading, the devices load
the data in a cache register while the previous data is transferred to the I/O buffers to be read.
Like all other 2-kB page NAND flash devices, a program operation typically writes 2112 bytes (×8), or 1056 words (×16) in 200 µs
and an erase operation can typically be performed in 2 ms (S34ML01G1) on a 128-kB block (×8) or 64-kword block (×16). In
addition, thanks to multiplane architecture, it is possible to program two pages at a time (one per plane) or to erase two blocks at a
time (again, one per plane). The multiplane architecture allows program time to be reduced by 40% and erase time to be reduced by
50%.
In multiplane operations, data in the page can be read out at 25 ns cycle time per byte. The I/O pins serve as the ports for command
and address input as well as data input/output. This interface allows a reduced pin count and easy migration towards different
densities, without any rearrangement of the footprint.
Commands, Data, and Addresses are asynchronously introduced using CE#, WE#, ALE, and CLE control pins.
The on-chip Program/Erase Controller automates all read, program, and erase functions including pulse repetition, where required,
and internal verification and margining of data. A WP# pin is available to provide hardware protection against program and erase
operations.
The output pin R/B# (open drain buffer) signals the status of the device during each operation. It identifies if the program/erase/read
controller is currently active. The use of an open-drain output allows the Ready/Busy pins from several memories to connect to a
single pull-up resistor. In a system with multiple memories the
R/B# pins can be connected all together to provide a global status signal.
The Reprogram function allows the optimization of defective block management — when a Page Program operation fails the data
can be directly programmed in another page inside the same array section without the time consuming serial data insertion phase.
The Copy Back operation automatically executes embedded error detection operation: 1-bit error out of every 528 bytes (×8) or 256
words (×16) can be detected. With this feature it is no longer necessary to use an external mechanism to detect Copy Back
operation errors.
Multiplane Copy Back is also supported. Data read out after Copy Back Read (both for single and multiplane cases) is allowed.
In addition, Cache Program and Multiplane Cache Program operations improve the programing throughput by programing data
using the cache register.
The devices provide two innovative features: Page Reprogram and Multiplane Page Reprogram. The Page Reprogram re-programs
one page. Normally, this operation is performed after a failed Page Program operation. Similarly, the Multiplane Page Reprogram reprograms two pages in parallel, one per plane. The first page must be in the first plane while the second page must be in the second
plane. The Multiplane Page Reprogram operation is performed after a failed Multiplane Page Program operation. The Page
Reprogram and Multiplane Page Reprogram guarantee improved performance, since data insertion can be omitted during reprogram operations.
Note: The S34ML01G1 device does not support EDC.
Document Number: 002-00676 Rev. *T
Page 3 of 73
S34ML01G1
S34ML02G1, S34ML04G1
The devices come with an OTP (one time programmable) area, which is a restricted access area where sensitive data/code can be
stored permanently. This security feature is subject to an NDA (non-disclosure agreement) and is, therefore, not described in the
data sheet. For more details, contact your nearest Cypress sales office.
Density (bits)
Device
Main
S34ML01G1
S34ML02G1
S34ML04G1
1.1
Number of Planes
Number of Blocks
per Plane
EDC Support
1
1024
No
2
1024
Yes
2
2048
Yes
Spare
128M x 8
4M x 8
64M x 16
2M x 16
256M x 8
8M x 8
128M x 16
4M x 16
512M x 8
16M x 8
256M x 16
8M x 16
Logic Diagram
Figure 1.1 Logic Diagram
VCC
I/O0~I/O7
CE#
WE#
R/B#
RE#
ALE
CLE
WP#
VSS
Table 1.1 Signal Names
I/O7 - I/O0 (×8)
Data Input / Outputs
I/O8 - I/O15 (×16)
CLE
Command Latch Enable
ALE
Address Latch Enable
CE#
Chip Enable
RE#
Read Enable
WE#
Write Enable
WP#
Write Protect
R/B#
Read/Busy
VCC
Power Supply
VSS
Ground
NC
Not Connected
Document Number: 002-00676 Rev. *T
Page 4 of 73
S34ML01G1
S34ML02G1, S34ML04G1
1.2
Connection Diagram
Figure 1.2 48-Pin TSOP1 Contact ×8, ×16 Devices
x16
x8
NC
NC
NC
NC
NC
NC
R/B#
RE#
CE#
NC
NC
VCC
VSS
NC
NC
CLE
ALE
WE#
WP#
NC
NC
NC
NC
NC
NC
NC
NC
NC
NC
NC
R/B#
RE#
CE#
NC
NC
VCC
VSS
NC
NC
CLE
ALE
WE#
WP#
NC
NC
NC
NC
NC
1
12
13
48
NAND Flash
TSOP1
37
36
25
24
x8
x16
VSS (1)
NC
NC
NC
I/O7
I/O6
I/O5
I/O4
NC
VCC(1)
NC
VCC
VSS
NC
VCC(1)
NC
I/O3
I/O2
I/O1
I/O0
NC
NC
NC
VSS (1)
VSS
I/O15
I/O14
I/O13
I/O7
I/O6
I/O5
I/O4
I/O12
VCC
NC
VCC
VSS
NC
VCC
I/011
I/O3
I/O2
I/O1
I/O0
I/O10
I/O9
I/O8
VSS
Note:
1. These pins should be connected to power supply or ground (as designated) following the ONFI specification, however they might not be bonded internally.
Figure 1.3 63-BGA Contact, ×8 Device (Balls Down, Top View)
A1
A2
A9
NC
NC
NC
NC
B9
B10
NC
NC
B1
NC
C3
C4
C5
C6
C7
C8
WP#
ALE
VSS
CE#
WE#
RB#
D3
D4
D5
D6
D7
D8
VCC (1)
RE#
CLE
NC
NC
NC
E3
E4
E5
E6
E7
E8
NC
NC
NC
NC
NC
NC
F3
F4
F5
F6
F7
F8
NC
NC
NC
NC
VSS (1)
NC
G3
G4
G5
G6
G7
G8
NC
VCC (1)
NC
NC
NC
NC
H3
H4
H5
H6
H7
H8
NC
I/O0
NC
NC
NC
Vcc
J3
J4
J5
J6
J7
J8
NC
I/O1
NC
VCC
I/O5
I/O7
K3
K4
K5
K6
K7
K8
VSS
I/O2
I/O3
I/O4
I/O6
VSS
A10
L1
L2
L9
L10
NC
NC
NC
NC
M1
M2
M9
M10
NC
NC
NC
NC
Note:
1. These pins should be connected to power supply or ground (as designated) following the ONFI specification, however they might not be bonded internally.
Document Number: 002-00676 Rev. *T
Page 5 of 73
S34ML01G1
S34ML02G1, S34ML04G1
Figure 1.4 63-BGA Contact, ×16 Device (Balls Down, Top View)
A1
A2
A9
NC
NC
NC
NC
B9
B10
NC
NC
B1
NC
1.3
C3
C4
C5
C6
C7
C8
WP#
ALE
VSS
CE#
WE#
RB#
D3
D4
D5
D6
D7
D8
VCC
RE#
CLE
NC
NC
NC
E3
E4
E5
E6
E7
E8
NC
NC
NC
NC
NC
NC
F3
F4
F5
F6
F7
F8
NC
NC
NC
NC
VSS
NC
G3
G4
G5
G6
G7
G8
NC
VCC
NC
I/O13
I/O15
NC
H3
H4
H5
H6
H7
H8
I/O8
I/O0
I/O10
I/O12
I/O14
Vcc
J3
J4
J5
J6
J7
J8
I/O9
I/O1
I/O11
VCC
I/O5
I/O7
K3
K4
K5
K6
K7
K8
VSS
I/O2
I/O3
I/O4
I/O6
VSS
A10
L1
L2
L9
L10
NC
NC
NC
NC
M1
M2
M9
M10
NC
NC
NC
NC
Pin Description
Table 1.2 Pin Description
Pin Name
Description
I/O0 - I/O7 (×8)
Inputs/Outputs. The I/O pins are used for command input, address input, data input, and data output. The
I/O8 - I/O15 (×16) I/O pins float to High-Z when the device is deselected or the outputs are disabled.
CLE
Command Latch Enable. This input activates the latching of the I/O inputs inside the Command Register on the rising
edge of Write Enable (WE#).
ALE
Address Latch Enable. This input activates the latching of the I/O inputs inside the Address Register on the rising
edge of Write Enable (WE#).
CE#
Chip Enable. This input controls the selection of the device. When the device is not busy CE# low selects the memory.
WE#
Write Enable. This input latches Command, Address and Data. The I/O inputs are latched on the rising edge of WE#.
RE#
Read Enable. The RE# input is the serial data-out control, and when active drives the data onto the I/O bus. Data is
valid tREA after the falling edge of RE# which also increments the internal column address counter by one.
WP#
Write Protect. The WP# pin, when low, provides hardware protection against undesired data modification
(program / erase).
R/B#
Ready Busy. The Ready/Busy output is an Open Drain pin that signals the state of the memory.
VCC
Supply Voltage. The VCC supplies the power for all the operations (Read, Program, Erase). An internal lock circuit
prevents the insertion of Commands when VCC is less than VLKO.
VSS
Ground.
NC
Not Connected.
Notes:
1. A 0.1 µF capacitor should be connected between the VCC Supply Voltage pin and the VSS Ground pin to decouple the current surges from the power supply. The PCB
track widths must be sufficient to carry the currents required during program and erase operations.
2. An internal voltage detector disables all functions whenever VCC is below 1.8V to protect the device from any involuntary program/erase during power transitions.
Document Number: 002-00676 Rev. *T
Page 6 of 73
S34ML01G1
S34ML02G1, S34ML04G1
1.4
Block Diagram
Figure 1.5 Functional Block Diagram
Address
Register/
Counter
Program Erase
Controller
HV Generation
1024 Mbit + 32 Mbit (1 Gb Device)
X
2048 Mbit + 64 Mbit (2 Gb Device)
D
E
C
O
D
E
R
4096 Mbit + 128 Mbit (4 Gb Device)
ALE
CLE
NAND Flash
Memory Array
WE#
CE#
WP#
Command
Interface
Logic
RE#
PAGE Buffer
Command
Register
Y Decoder
I/O Buffer
Data
Register
I/O0~I/O7 (x8)
I/O0~I/O15 (x16)
Document Number: 002-00676 Rev. *T
Page 7 of 73
S34ML01G1
S34ML02G1, S34ML04G1
1.5
Array Organization
Figure 1.6 Array Organization — ×8
1 Page = (2k + 64) bytes
Plane(s)
1024
Blocks
per
Plane
0
1 Block = (2k + 64) bytes x 64 pages
= (128k + 4k) bytes
1
1 Plane = (128k + 4k) bytes x 1024 Blocks
2
Note:
For 1 Gb and 2 Gb devices there are 1024 Blocks per Plane
For 4 Gb device there are 2048 Blocks per Plane
2 Gb and 4 Gb devices have two Planes
1022
1023
I/O
[7:0]
Page Buffer
2048 bytes
64 bytes
Array Organization (x8)
Figure 1.7 Array Organization — ×16
1 Page = (1k + 32) words
Plane(s)
1024
Blocks
per
Plane
0
1 Block = (1k + 32) words x 64 pages
= (64k + 2k) words
1
1 Plane = (64k + 2k) words x 1024 Blocks
2
Note:
For 1 Gb and 2 Gb devices there are 1024 Blocks per Plane
For 4 Gb device there are 2048 Blocks per Plane
2 Gb and 4 Gb devices have two Planes
1022
1023
I/O0~I/O15
Page Buffer
1024 words
32 words
Array Organization (x16)
Document Number: 002-00676 Rev. *T
Page 8 of 73
S34ML01G1
S34ML02G1, S34ML04G1
1.6
Addressing
1.6.1
S34ML01G1
Table 1.3 Address Cycle Map — 1 Gb Device
Bus Cycle
I/O [15:8] (5)
I/O0
I/O1
I/O2
I/O3
I/O4
I/O5
I/O6
I/O7
A4 (CA4)
A5 (CA5)
A6 (CA6)
A7 (CA7)
×8
1st / Col. Add. 1
—
A0 (CA0)
A1 (CA1)
A2 (CA2)
A3 (CA3)
2nd / Col. Add. 2
—
3rd / Row Add. 1
—
A8 (CA8)
A9 (CA9)
A10 (CA10)
A11 (CA11)
Low
Low
Low
Low
A12 (PA0)
A13 (PA1)
A14 (PA2)
A15 (PA3)
A16 (PA4)
A17 (PA5)
A18 (BA0)
A19 (BA1)
4th / Row Add. 2
—
A20 (BA2)
A21 (BA3)
A22 (BA4)
A23 (BA5)
A24 (BA6)
A25 (BA7)
A26 (BA8)
A27 (BA9)
A7 (CA7)
×16
1st / Col. Add. 1
Low
A0 (CA0)
A1 (CA1)
A2 (CA2)
A3 (CA3)
A4 (CA4)
A5 (CA5)
A6 (CA6)
2nd / Col. Add. 2
Low
A8 (CA8)
A9 (CA9)
A10 (CA10)
Low
Low
Low
Low
Low
3rd / Row Add. 1
Low
A11 (PA0)
A12 (PA1)
A13 (PA2)
A14 (PA3)
A15 (PA4)
A16 (PA5)
A17 (BA0)
A18 (BA1)
4th / Row Add. 2
Low
A19 (BA2)
A20 (BA3)
A21 (BA4)
A22 (BA5)
A23 (BA6)
A24 (BA7)
A25 (BA8)
A26 (BA9)
Notes:
1. CAx = Column Address bit.
2. PAx = Page Address bit.
3. BAx = Block Address bit.
4. Block address concatenated with page address = actual page address, also known as the row address.
5. I/O[15:8] are not used during the addressing sequence and should be driven Low.
For the ×8 address bits, the following rules apply:
A0 - A11: column address in the page
A12 - A17: page address in the block
A18 - A27: block address
For the ×16 address bits, the following rules apply:
A0 - A10: column address in the page
A11 - A16: page address in the block
A17 - A26: block address
Document Number: 002-00676 Rev. *T
Page 9 of 73
S34ML01G1
S34ML02G1, S34ML04G1
1.6.2
S34ML02G1
Table 1.4 Address Cycle Map — 2 Gb Device
Bus Cycle
I/O [15:8] (6)
I/O0
I/O1
I/O2
I/O3
I/O4
I/O5
I/O6
I/O7
×8
1st / Col. Add. 1
—
A0 (CA0)
A1 (CA1)
A2 (CA2)
A3 (CA3)
A4 (CA4)
A5 (CA5)
A6 (CA6)
A7 (CA7)
2nd / Col. Add. 2
—
A8 (CA8)
A9 (CA9)
A10 (CA10)
A11 (CA11)
Low
Low
Low
Low
A19 (BA0)
3rd / Row Add. 1
—
A12 (PA0)
A13 (PA1)
A14 (PA2)
A15 (PA3)
A16 (PA4)
A17 (PA5)
A18
(PLA0)
4th / Row Add. 2
—
A20 (BA1)
A21 (BA2)
A22 (BA3)
A23 (BA4)
A24 (BA5)
A25 (BA6)
A26 (BA7)
A27 (BA8)
5th / Row Add. 3
—
A28 (BA9)
Low
Low
Low
Low
Low
Low
Low
1st / Col. Add. 1
Low
A0 (CA0)
A1 (CA1)
A2 (CA2)
A3 (CA3)
A4 (CA4)
A5 (CA5)
A6 (CA6)
A7 (CA7)
2nd / Col. Add. 2
Low
A8 (CA8)
A9 (CA9)
A10 (CA10)
Low
Low
Low
Low
Low
A18 (BA0)
×16
3rd / Row Add. 1
Low
A11 (PA0)
A12 (PA1)
A13 (PA2)
A14 (PA3)
A15 (PA4)
A16 (PA5)
A17
(PLA0)
4th / Row Add. 2
Low
A19 (BA1)
A20 (BA2)
A21 (BA3)
A22 (BA4)
A23 (BA5)
A24 (BA6)
A25 (BA7)
A26 (BA8)
5th / Row Add. 3
Low
A27 (BA9)
Low
Low
Low
Low
Low
Low
Low
Notes:
1. CAx = Column Address bit.
2. PAx = Page Address bit.
3. PLA0 = Plane Address bit zero.
4. BAx = Block Address bit.
5. Block address concatenated with page address and plane address = actual page address, also known as the row address.
6. I/O[15:8] are not used during the addressing sequence and should be driven Low.
For the ×8 address bits, the following rules apply:
A0 - A11: column address in the page
A12 - A17: page address in the block
A18: plane address (for multiplane operations) / block address (for normal operations)
A19 - A28: block address
For the ×16 address bits, the following rules apply:
A0 - A10: column address in the page
A11 - A16: page address in the block
A17: plane address (for multiplane operations) / block address (for normal operations)
A18 - A27: block address
Document Number: 002-00676 Rev. *T
Page 10 of 73
S34ML01G1
S34ML02G1, S34ML04G1
1.6.3
S34ML04G1
Table 1.5 Address Cycle Map — 4 Gb Device
Bus Cycle
I/O [15:8] (6)
I/O0
I/O1
I/O2
I/O3
I/O4
I/O5
I/O6
I/O7
A3 (CA3)
A4 (CA4)
A5 (CA5)
A6 (CA6)
A7 (CA7)
Low
Low
Low
Low
A19 (BA0)
×8
1st / Col. Add. 1
—
A0 (CA0)
A1 (CA1)
2nd / Col. Add. 2
—
A8 (CA8)
A9 (CA9)
A2 (CA2)
A10 (CA10) A11 (CA11)
3rd / Row Add. 1
—
A12 (PA0)
A13 (PA1)
A14 (PA2)
A15 (PA3)
A16 (PA4)
A17 (PA5)
A18
(PLA0)
4th / Row Add. 2
—
A20 (BA1)
A21 (BA2)
A22 (BA3)
A23 (BA4)
A24 (BA5)
A25 (BA6)
A26 (BA7)
A27 (BA8)
Low
Low
Low
Low
Low
Low
5th / Row Add. 3
—
A28 (BA9)
A29
(BA10)
1st / Col. Add. 1
Low
A0 (CA0)
A1 (CA1)
A2 (CA2)
A3 (CA3)
A4 (CA4)
A5 (CA5)
A6 (CA6)
A7 (CA7)
2nd / Col. Add. 2
Low
A8 (CA8)
A9 (CA9)
A10 (CA10)
Low
Low
Low
Low
Low
3rd / Row Add. 1
Low
A11 (PA0)
A12 (PA1)
A13 (PA2)
A14 (PA3)
A15 (PA4)
A16 (PA5)
A17
(PLA0)
A18 (BA0)
4th / Row Add. 2
Low
A19 (BA1)
A20 (BA2)
A21 (BA3)
A22 (BA4)
A23 (BA5)
A24 (BA6)
A25 (BA7)
A26 (BA8)
A27 (BA9)
A28
(BA10)
Low
Low
Low
Low
Low
Low
×16
5th / Row Add. 3
Low
Notes:
1. CAx = Column Address bit.
2. PAx = Page Address bit.
3. PLA0 = Plane Address bit zero.
4. BAx = Block Address bit.
5. Block address concatenated with page address and plane address = actual page address, also known as the row address.
6. I/O[15:8] are not used during the addressing sequence and should be driven Low.
For the ×8 address bits, the following rules apply:
A0 - A11: column address in the page
A12 - A17: page address in the block
A18: plane address (for multiplane operations) / block address (for normal operations)
A19 - A29: block address
For the ×16 address bits, the following rules apply:
A0 - A10: column address in the page
A11 - A16: page address in the block
A17: plane address (for multiplane operations) / block address (for normal operations)
A18 - A28: block address
Document Number: 002-00676 Rev. *T
Page 11 of 73
S34ML01G1
S34ML02G1, S34ML04G1
1.7
Mode Selection
Table 1.6 Mode Selection
Mode
CLE
ALE
CE#
WE#
RE#
WP#
High
Low
Low
Rising
High
X
Address Input
Low
High
Low
Rising
High
X
Command Input
High
Low
Low
Rising
High
High
Address Input
Command Input
Read Mode
Program or Erase Mode
Low
High
Low
Rising
High
High
Data Input
Low
Low
Low
Rising
High
High
Data Output (on going)
X
Low
Low
Low
High
Falling
Data Output (suspended)
X
X
X
High
High
X
Busy Time in Read
X
X
X
High
High (3)
X
Busy Time in Program
X
X
X
X
X
High
Busy Time in Erase
X
X
X
X
X
High
Write Protect
X
X
X
X
X
Low
Stand By
X
X
High
X
X
0V / VCC (2)
Notes:
1. X can be VIL or VIH. High= Logic level high. Low = Logic level low.
2. WP# should be biased to CMOS high or CMOS low for stand-by mode.
3. During Busy Time in Read, RE# must be held high to prevent unintended data out.
2. Bus Operation
There are six standard bus operations that control the device: Command Input, Address Input, Data Input, Data Output, Write
Protect, and Standby. (See Table 1.6.)
Typically glitches less than 5 ns on Chip Enable, Write Enable, and Read Enable are ignored by the memory and do not affect bus
operations.
2.1
Command Input
The Command Input bus operation is used to give a command to the memory device. Commands are accepted with Chip Enable
low, Command Latch Enable high, Address Latch Enable low, and Read Enable high and latched on the rising edge of Write Enable.
Moreover, for commands that start a modify operation (program/erase) the Write Protect pin must be high. See Figure 6.1
on page 37 and Table 5.5 on page 35 for details of the timing requirements. Command codes are always applied on I/O7:0
regardless of the bus configuration (×8 or ×16).
2.2
Address Input
The Address Input bus operation allows the insertion of the memory address. For the S34ML02G1 and S34ML04G1 devices, five
write cycles are needed to input the addresses. For the S34ML01G1, four write cycles are needed to input the addresses. If
necessary, a 5th dummy address cycle can be issued to S34ML01G1, which will be ignored by the NAND device without causing
problems. Addresses are accepted with Chip Enable low, Address Latch Enable high, Command Latch Enable low, and Read
Enable high and latched on the rising edge of Write Enable. Moreover, for commands that start a modify operation (program/erase)
the Write Protect pin must be high. See Figure 6.2 on page 38 and Table 5.5 on page 35 for details of the timing requirements.
Addresses are always applied on I/O7:0 regardless of the bus configuration (×8 or ×16). Refer to Table 1.3 through Table 1.5
on page 11 for more detailed information.
Document Number: 002-00676 Rev. *T
Page 12 of 73
S34ML01G1
S34ML02G1, S34ML04G1
2.3
Data Input
The Data Input bus operation allows the data to be programmed to be sent to the device. The data insertion is serial and timed by
the Write Enable cycles. Data is accepted only with Chip Enable low, Address Latch Enable low, Command Latch Enable low, Read
Enable high, and Write Protect high and latched on the rising edge of Write Enable. See Figure 6.3 on page 38 and Table 5.5
on page 35 for details of the timing requirements.
2.4
Data Output
The Data Output bus operation allows data to be read from the memory array and to check the Status Register content, the EDC
register content, and the ID data. Data can be serially shifted out by toggling the Read Enable pin with Chip Enable low, Write
Enable high, Address Latch Enable low, and Command Latch Enable low. See Figure 6.4 on page 39 and Table 5.5 on page 35 for
details of the timings requirements.
2.5
Write Protect
The Hardware Write Protection is activated when the Write Protect pin is low. In this condition, modify operations do not start and the
content of the memory is not altered. The Write Protect pin is not latched by Write Enable to ensure the protection even during power
up.
2.6
Standby
In Standby, the device is deselected, outputs are disabled, and power consumption is reduced.
Document Number: 002-00676 Rev. *T
Page 13 of 73
S34ML01G1
S34ML02G1, S34ML04G1
3. Command Set
Table 3.1 Command Set
Command
Acceptable
Command
during Busy
Supported on
S34ML01G1
30h
No
Yes
10h
No
Yes
1st Cycle
2nd Cycle
Page Read
00h
Page Program
80h
Random Data Input
85h
Random Data Output
05h
E0h
Multiplane Program
80h
11h
81h
80h
ONFI Multiplane Program
80h
11h
Page Reprogram
8Bh
10h
Multiplane Page Reprogram
8Bh
11h
Block Erase
60h
D0h
3rd Cycle
8Bh
Multiplane Block Erase
60h
60h
D0h
ONFI Multiplane Block Erase
60h
D1h
60h
Copy Back Read
00h
Copy Back Program
85h
4th Cycle
No
Yes
No
Yes
10h
No
No
10h
No
No
10h
No
No
No
No
No
Yes
No
No
No
No
35h
No
Yes
10h
No
Yes
D0h
Multiplane Copy Back Program
85h
11h
81h
10h
No
No
ONFI Multiplane Copy Back Program
85h
11h
85h
10h
No
No
Special Read For Copy Back
00h
36h
No
No
Read EDC Status Register
7Bh
Yes
No
Read Status Register
70h
Yes
Yes
Read Status Enhanced
78h
Yes
No
Reset
FFh
Yes
Yes
Read Cache
31h
No
Yes
Read Cache Enhanced
00h
Read Cache End
3Fh
Cache Program (End)
80h
Cache Program (Start) / (Continue)
80h
31h
No
No
No
Yes
10h
No
Yes
15h
No
Yes
Multiplane Cache Program (Start/Continue)
80h
11h
81h
15h
No
No
ONFI Multiplane Cache Program (Start/Continue)
80h
11h
80h
15h
No
No
Multiplane Cache Program (End)
80h
11h
81h
10h
No
No
ONFI Multiplane Cache Program (End)
80h
11h
80h
10h
No
No
Read ID
90h
Read ID2
30h-65h-00h
30h
No
Yes
No
Yes
Read ONFI Signature
90h
No
Yes
Read Parameter Page
ECh
No
Yes
29h-17h-04h-19h
No
Yes
One-time Programmable (OTP) Area Entry
Document Number: 002-00676 Rev. *T
Page 14 of 73
S34ML01G1
S34ML02G1, S34ML04G1
3.1
Page Read
Page Read is initiated by writing 00h and 30h to the command register along with five address cycles (four or five cycles for
S34ML01G1). Two types of operations are available: random read and serial page read. Random read mode is enabled when the
page address is changed. All data within the selected page are transferred to the data registers. The system controller may detect
the completion of this data transfer (tR) by analyzing the output of the R/B pin. Once the data in a page is loaded into the data
registers, they may be read out in 25 ns cycle time by sequentially pulsing RE#. The repetitive high to low transitions of the RE#
signal makes the device output the data, starting from the selected column address up to the last column address.
The device may output random data in a page instead of the sequential data by writing Random Data Output command. The column
address of next data, which is going to be out, may be changed to the address that follows Random Data Output command. Random
Data Output can be performed as many times as needed.
After power up, the device is in read mode, so 00h command cycle is not necessary to start a read operation. Any operation other
than read or Random Data Output causes the device to exit read mode.
See Figure 6.6 on page 40 and Figure 6.12 on page 44 as references.
3.2
Page Program
A page program cycle consists of a serial data loading period in which up to 2112 bytes (×8) or 1056 words (×16) of data may be
loaded into the data register, followed by a non-volatile programming period where the loaded data is programmed into the
appropriate cell.
The serial data loading period begins by inputting the Serial Data Input command (80h), followed by the five cycle address inputs
(four cycles for S34ML01G1) and then serial data. The words other than those to be programmed do not need to be loaded. The
device supports Random Data Input within a page. The column address of next data, which will be entered, may be changed to the
address that follows the Random Data Input command (85h). Random Data Input may be performed as many times as needed.
The Page Program confirm command (10h) initiates the programming process. The internal write state controller automatically
executes the algorithms and controls timings necessary for program and verify, thereby freeing the system controller for other tasks.
Once the program process starts, the Read Status Register commands (70h or 78h) may be issued to read the Status Register. The
system controller can detect the completion of a program cycle by monitoring the
R/B# output, or the Status bit (I/O6) of the Status Register. Only the Read Status commands (70h or 78h) or Reset command are
valid while programming is in progress. When the Page Program is complete, the Write Status Bit (I/O0) may be checked. The
internal write verify detects only errors for 1’s that are not successfully programmed to 0’s. The command register remains in Read
Status command mode until another valid command is written to the command register. Figure 6.9 on page 42 and Figure 6.11
on page 43 detail the sequence.
The device is programmable by page, but it also allows multiple partial page programming of a word or consecutive bytes up to 2112
bytes (×8) or 1056 words (×16) in a single page program cycle.
The number of consecutive partial page programming operations (NOP) within the same page must not exceed the number
indicated in Table 5.8 on page 37. Pages may be programmed in any order within a block.
Users who use “EDC check” (for S34ML02G1 and S34ML04G1 only) in copy back must comply with some limitations related to data
handling during one page program sequence. Refer to Section 3.8 on page 20 for details.
If a Page Program operation is interrupted by hardware reset, power failure or other means, the host must ensure that the
interrupted page is not used for further reading or programming operations until the next uninterrupted block erase is complete.
Document Number: 002-00676 Rev. *T
Page 15 of 73
S34ML01G1
S34ML02G1, S34ML04G1
3.3
Multiplane Program — S34ML02G1 and S34ML04G1
The S34ML02G1 and S34ML04G1 devices support Multiplane Program, making it possible to program two pages in parallel, one
page per plane.
A Multiplane Program cycle consists of a double serial data loading period in which up to 4224 bytes (×8) or 2112 words (×16) of
data may be loaded into the data register, followed by a non-volatile programming period where the loaded data is programmed into
the appropriate cell. The serial data loading period begins with inputting the Serial Data Input command (80h), followed by the five
cycle address inputs and serial data for the 1st page. The address for this page must be in the 1st plane (PLA0 = 0). The device
supports Random Data Input exactly the same as in the case of page program operation. The Dummy Page Program Confirm
command (11h) stops 1st page data input and the device becomes busy for a short time (tDBSY). Once it has become ready again,
the ‘81h’ command must be issued, followed by 2nd page address (5 cycles) and its serial data input. The address for this page
must be in the 2nd plane (PLA0 = 1). The Program Confirm command (10h) starts parallel programming of both pages.
Figure 6.13 on page 44 describes the sequences using the legacy protocol. In this case, the block address bits for the first plane are
all zero and the second address issued selects the block for both planes. Figure 6.14 on page 45 describes the sequences using the
ONFI protocol. For both addresses issued in this protocol, the block address bits must be the same except for the bit(s) that select
the plane.
The user can check operation status by monitoring R/B# pin or reading the Status Register (command 70h or 78h). The Read Status
Register command is also available during Dummy Busy time (tDBSY). In case of failure in either page program, the fail bit of the
Status Register will be set. Refer to Section 3.9 on page 22 for further info.
The number of consecutive partial page programming operations (NOP) within the same page must not exceed the number
indicated in Table 5.8 on page 37. Pages may be programmed in any order within a block.
If a Multiplane Program operation is interrupted by hardware reset, power failure or other means, the host must ensure that the
interrupted pages are not used for further reading or programming operations until the next uninterrupted block erases are complete
for the applicable blocks.
Document Number: 002-00676 Rev. *T
Page 16 of 73
S34ML01G1
S34ML02G1, S34ML04G1
3.4
Page Reprogram — S34ML02G1 and S34ML04G1
Page Program may result in a fail, which can be detected by Read Status Register. In this event, the host may call Page Reprogram.
This command allows the reprogramming of the same pattern of the last (failed) page into another memory location. The command
sequence initiates with reprogram setup (8Bh), followed by the five cycle address inputs of the target page. If the target pattern for
the destination page is not changed compared to the last page, the program confirm can be issued (10h) without any data input
cycle, as described in Figure 3.1.
Figure 3.1 Page Reprogram
As defined for Page
Program
CMD
Cycle Type
A
ADDR
ADDR
ADDR
ADDR
ADDR
Din
Din
Din
Din
CMD
D0
D1
...
Dn
10h
tADL
I/Ox
00h
C2
C1
R1
R3
R2
tWB
tPROG
SR[6]
Page N
A
Cycle Type
CMD
Dout
CMD
ADDR
ADDR
ADDR
ADDR
ADDR
CMD
I/Ox
70h
E1
8Bh
C1
C2
R1
R2
R3
10h
tWB
tPROG
SR[6]
FAIL !
Page M
On the other hand, if the pattern bound for the target page is different from that of the previous page, data in cycles can be issued
before program confirm ‘10h’, as described in Figure 3.2.
Figure 3.2 Page Reprogram with Data Manipulation
As defined for Page
Program
CMD
Cycle Type
ADDR
A
ADDR
ADDR
ADDR
ADDR
Din
Din
Din
Din
CMD
CMD
Dout
D0
D1
...
Dn
10h
70h
E1
tADL
IOx
80h
C1
C2
R1
R2
R3
tWB
tPROG
SR[6]
Cycle Type
FAIL !
Page N
A
CMD
ADDR
ADDR
ADDR
ADDR
ADDR
Din
Din
Din
Din
CMD
D0
D1
...
Dn
10h
tADL
I/Ox
8Bh
C1
C2
R1
R2
R3
tWB
tPROG
SR[6]
Page M
Document Number: 002-00676 Rev. *T
Page 17 of 73
S34ML01G1
S34ML02G1, S34ML04G1
The device supports Random Data Input within a page. The column address of next data, which will be entered, may be changed to
the address which follows the Random Data Input command (85h). Random Data Input may be operated multiple times regardless
of how many times it is done in a page.
The Program Confirm command (10h) initiates the re-programming process. The internal write state controller automatically
executes the algorithms and controls timings necessary for program and verify, thereby freeing the system controller for other tasks.
Once the program process starts, the Read Status Register command may be issued to read the Status Register. The system
controller can detect the completion of a program cycle by monitoring the R/B# output, or the Status bit (I/O6) of the Status Register.
Only the Read Status command and Reset command are valid when programming is in progress. When the Page Program is
complete, the Write Status Bit (I/O0) may be checked. The internal write verify detects only errors for 1’s that are not successfully
programmed to 0’s. The command register remains in Read Status command mode until another valid command is written to the
command register.
The Page Reprogram must be issued in the same plane as the Page Program that failed. In order to program the data to a different
plane, use the Page Program operation instead. The Multiplane Page Reprogram can re-program two pages in parallel, one per
plane. The Multiplane Page Reprogram operation is performed after a failed Multiplane Page Program operation. The command
sequence is very similar to Figure 6.13 on page 44, except that it requires the Page Reprogram Command (8Bh) instead of 80h and
81h.
If a Page Reprogram operation is interrupted by hardware reset, power failure or other means, the host must ensure that the
interrupted page is not used for further reading or programming operations until the next uninterrupted block erase is complete.
3.5
Block Erase
The Block Erase operation is done on a block basis. Block address loading is accomplished in three cycles (two cycles for
S34ML01G1) initiated by an Erase Setup command (60h). Only the block address bits are valid while the page address bits are
ignored.
The Erase Confirm command (D0h) following the block address loading initiates the internal erasing process. This two-step
sequence of setup followed by the execution command ensures that memory contents are not accidentally erased due to external
noise conditions.
At the rising edge of WE# after the erase confirm command input, the internal write controller handles erase and erase verify. Once
the erase process starts, the Read Status Register commands (70h or 78h) may be issued to read the Status Register.
The system controller can detect the completion of an erase by monitoring the R/B# output, or the Status bit
(I/O6) of the Status Register. Only the Read Status commands (70h or 78h) and Reset command are valid while erasing is in
progress. When the erase operation is completed, the Write Status Bit (I/O0) may be checked. Figure 6.15 on page 45 details the
sequence.
If a Block Erase operation is interrupted by hardware reset, power failure or other means, the host must ensure that the interrupted
block is erased under continuous power conditions before that block can be trusted for further programming and reading operations.
Document Number: 002-00676 Rev. *T
Page 18 of 73
S34ML01G1
S34ML02G1, S34ML04G1
3.6
Multiplane Block Erase — S34ML02G1 and S34ML04G1
Multiplane Block Erase allows the erase of two blocks in parallel, one block per memory plane.
The Block erase setup command (60h) must be repeated two times, followed by 1st and 2nd block address respectively (3 cycles
each). As for block erase, D0h command makes embedded operation start. In this case, multiplane erase does not need any
Dummy Busy Time between 1st and 2nd block insertion. See Table 5.8 on page 37 for performance information.
For the Multiplane Block Erase operation, the address of the first block must be within the first plane
(PLA0 = 0) and the address of the second block in the second plane (PLA0 = 1). See Figure 6.16 on page 46 for a description of the
legacy protocol. In this case, the block address bits for the first plane are all zero and the second address issued selects the block
for both planes. Figure 6.17 on page 46 describes the sequences using the ONFI protocol. For both addresses issued in this
protocol, the block address bits must be the same except for the bit(s) that select the plane.
The user can check operation status by monitoring R/B# pin or reading the Status Register (command 70h or 78h). The Read Status
Register command is also available during Dummy Busy time (tDBSY). In case of failure in either erase, the fail bit of the Status
Register will be set. Refer to Section 3.9 on page 22 for further information.
If a Multiplane Block Erase operation is interrupted by hardware reset, power failure or other means, the host must ensure that the
interrupted blocks are erased under continuous power conditions before those blocks can be trusted for further programming and
reading operations.
3.7
Copy Back Program
The copy back feature is intended to quickly and efficiently rewrite data stored in one page without utilizing an external memory.
Since the time-consuming cycles of serial access and re-loading cycles are removed, the system performance is greatly improved.
The benefit is especially obvious when a portion of a block needs to be updated and the rest of the block also needs to be copied to
the newly assigned free block. The operation for performing a copy back is a sequential execution of page-read (without mandatory
serial access) and Copy Back Program with the address of destination page. A read operation with the ‘35h’ command and the
address of the source page moves the whole page of data into the internal data register. As soon as the device returns to the Ready
state, optional data read-out is allowed by toggling RE# (see Figure 6.18 on page 47), or the Copy Back Program command (85h)
with the address cycles of the destination page may be written. The Program Confirm command (10h) is required to actually begin
programming.
The source and the destination pages in the Copy Back Program sequence must belong to the same device plane (same PLA0 for
S34ML02G1 and S34ML04G1). Copy Back Read and Copy Back Program for a given plane must be between odd address pages or
between even address pages for the device to meet the program time (tPROG) specification. Copy Back Program may not meet this
specification when copying from an odd address page (source page) to an even address page (target page) or from an even
address page (source page) to an odd address page (target page).
The data input cycle for modifying a portion or multiple distinct portions of the source page is allowed as shown in Figure 6.19
on page 47. As noted in Section 1. on page 3 the device may include an automatic EDC (for S34ML02G1 and S34ML04G1) check
during the copy back operation, to detect single bit errors in EDC units contained within the source page. More details on EDC
operation and limitations related to data input handling during one Copy Back Program sequence are available in Section 3.8
on page 20.
If a Copy Back Program operation is interrupted by hardware reset, power failure or other means, the host must ensure that the
interrupted page is not used for further reading or programming operations until the next uninterrupted block erase is complete.
Document Number: 002-00676 Rev. *T
Page 19 of 73
S34ML01G1
S34ML02G1, S34ML04G1
3.7.1
Multiplane Copy Back Program — S34ML02G1 and S34ML04G1
The device supports Multiplane Copy Back Program with exactly the same sequence and limitations as the Page Program.
Multiplane Copy Back Program must be preceded by two single page Copy Back Read command sequences (1st page must be
read from the 1st plane and 2nd page from the 2nd plane).
Multiplane Copy Back cannot cross plane boundaries — the contents of the source page of one device plane can be copied only to
a destination page of the same plane. EDC check is available also for Multiplane Copy Back Program only for S34ML02G1 and
S34ML04G1.
When “EDC check” is used in copy back, it must comply with some limitations related to data handling during one Multiplane Copy
Back Program sequence. Please refer to Section 3.8 on page 20 for details on EDC operation. The Multiplane Copy Back Program
sequence represented in Figure 6.20 on page 48 shows the legacy protocol. In this case, the block address bits for the first plane
are all zero and the second address issued selects the block for both planes. Figure 6.21 on page 49 describes the sequence using
the ONFI protocol. For both addresses issued in this protocol, the block address bits must be the same except for the bit(s) that
select the plane.
If a Multiplane Copy Back Program operation is interrupted by hardware reset, power failure or other means, the host must ensure
that the interrupted pages are not used for further reading or programming operations until the next uninterrupted block erases are
complete for the applicable blocks.
3.7.2
Special Read for Copy Back — S34ML02G1 and S34ML04G1
The S34ML02G1 and S34ML04G1 devices support Special Read for Copy Back. If Copy Back Read (described in Section 3.7 and
Section 3.7.1 on page 20) is triggered with confirm command ‘36h’ instead ‘35h’, Copy Back Read from target page(s) will be
executed with an increased internal (VPASS) voltage.
This special feature is used in order to minimize the number of read errors due to over-program or read disturb — it shall be used
only if ECC read errors have occurred in the source page using Page Read or Copy Back Read sequences.
Excluding the Copy Back Read confirm command, all other features described in Section 3.7 and Section 3.7.1 for standard copy
back remain valid (including the figures referred to in those sections).
3.8
EDC Operation — S34ML02G1 and S34ML04G1
Error Detection Code check is a feature that can be used during the copy back operation (both single and multiplane) to detect
single bit errors occurring in the source page(s).
Note: The S34ML01G1 device does not support EDC.
EDC check allows detection of up to 1 single bit error every 528 bytes, where each 528 byte group is composed of 512
bytes of main array and 16 bytes of spare area (see Table 3.3 and Table 3.4 on page 22). The described 528-byte area is
called an “EDC unit.”
In the ×16 device, EDC allows detection of up to 1 single bit error every 264 words, where each 264 word group is
composed by 256 words of main array and 8 words of spare area see Table 3.3 and Table 3.4 on page 22). The described
264-word area is called “EDC unit.”
EDC results can be checked through a specific Read EDC register command, available only after issuing a Copy Back Program or a
Multiplane Copy Back Program. The EDC register can be queried during the copy back program busy time (tPROG).
For the “EDC check” feature to operate correctly, specific conditions on data input handling apply for program operations.
For the case of Page Program, Multiplane Page Program, Page Reprogram, Multiplane Page Reprogram, Cache Program, and
Multiplane Cache Program operations:
In Section 3.2 on page 15 it was explained that a number of consecutive partial program operations (NOP) is allowed within
the same page. In case this feature is used, the number of partial program operations occurring in the same EDC unit must
not exceed 1. In other words, page program operations must be performed on the whole page, or on whole EDC unit at a
time.
“Random Data Input” in a given EDC unit can be executed several times during one page program sequence, but data
cannot be written to any column address more than once before the program is initiated.
Document Number: 002-00676 Rev. *T
Page 20 of 73
S34ML01G1
S34ML02G1, S34ML04G1
For the case of Copy Back Program or Multiplane Copy Back Program operations:
If Random Data Input is applied in a given EDC unit, the entire EDC unit must be written to the page buffer. In other words,
the EDC check is possible only if the whole EDC unit is modified during one Copy Back Program sequence.
“Random Data Input” in a given EDC unit can be executed several times during one Copy Back Program sequence, but
data insertion in each column address of the EDC unit must not exceed 1.
If you use copy back without EDC check, none of the limitations described above apply.
After a Copy Back Program operation, the host can use Read EDC Status Register to check the status of both the program
operation and the Copy Back Read. If the EDC was valid and an error was reported in the EDC (see Table 3.2 on page 21), the host
may perform Special Read For Copy Back on the source page and attempt the Copy Back Program again. If this also fails, the host
can execute a Page Read operation in order to correct a single bit error with external ECC software or hardware.
3.8.1
Read EDC Status Register — S34ML02G1 and S34ML04G1
This operation is available only after issuing a Copy Back Program and it allows the detection of errors during Copy Back Read. In
the case of multiplane copy back, it is not possible to know which of the two read operations caused the error.
After writing the Read EDC Status Register command (7Bh) to the command register, a read cycle outputs the content of the EDC
Register to the I/O pins on the falling edge of CE# or RE#, whichever occurs last.
The operation is the same as the Read Status Register command. Refer to Table 3.2 for specific EDC Register definitions:
Table 3.2 EDC Register Coding
ID
Copy Back Program
Coding
0
Pass / Fail
Pass: 0; Fail: 1
1
EDC status
No error: 0; Error: 1
2
EDC validity
Invalid: 0; Valid: 1
3
NA
—
4
NA
—
5
Ready / Busy
Busy: 0; Ready: 1
6
Ready / Busy
Busy: 0; Ready: 1
7
Write Protect
Protected: 0; Not Protected: 1
Table 3.3 Page Organization in EDC Units
Main Field (2048 Byte)
Spare Field (64 Byte)
“A” area
“B” area
“C” area
“D” area
“E” area
“F” area
“G” area
“H” area
(1st sector)
(2nd sector)
(3rd sector)
(4th sector)
(1st sector)
(2nd sector)
(3rd sector)
(4th sector)
512 byte
512 byte
512 byte
512 byte
16 byte
16 byte
16 byte
16 byte
256 words
256 words
256 words
256 words
8 words
8 words
8 words
8 words
×8
×16
Document Number: 002-00676 Rev. *T
Page 21 of 73
S34ML01G1
S34ML02G1, S34ML04G1
Table 3.4 Page Organization in EDC Units by Address
Main Field (Column 0-2047)
Spare Field (Column 2048-2111)
Sector
Area Name
Column Address
Area Name
Column Address
×8
1st 528-byte Sector
A
0-511
E
2048-2063
2nd 528-byte Sector
B
512-1023
F
2064-2079
3rd 528-byte Sector
C
1024-1535
G
2080-2095
4th 528-byte Sector
D
1536-2047
H
2096-2111
E
1024-1031
×16
1st 256-word Sector
A
0-255
2nd 256-word Sector
B
256-511
F
1032-1039
3rd 256-word Sector
C
512-767
G
1040-1047
4th 256-word Sector
D
768-1023
H
1048-1055
3.9
Read Status Register
The Status Register is used to retrieve the status value for the last operation issued. After writing 70h command to the command
register, a read cycle outputs the content of the Status Register to the I/O pins on the falling edge of CE# or RE#, whichever occurs
last. This two-line control allows the system to poll the progress of each device in multiple memory connections even when R/B#
pins are common-wired. Refer to Section 3.5 on page 23 for specific Status Register definition, and to Figure 6.22 on page 49 for
timings.
If the Read Status Register command is issued during multiplane operations then Status Register polling will return the combined
status value related to the outcome of the operation in the two planes according to the following table:
Status Register Bit
Composite Status Value
Bit 0, Pass/Fail
OR
Bit 1, Cache Pass/Fail
OR
In other words, the Status Register is dynamic; the user is not required to toggle RE# / CE# to update it.
The command register remains in Status Read mode until further commands are issued. Therefore, if the Status Register is read
during a random read cycle, the read command (00h) must be issued before starting read cycles.
Note: The Read Status Register command shall not be used for concurrent operations in multi-die stack configurations (single CE#).
“Read Status Enhanced” shall be used instead.
3.10
Read Status Enhanced — S34ML02G1 and S34ML04G1
Read Status Enhanced is used to retrieve the status value for a previous operation in the specified plane.
Figure 6.23 on page 50 defines the Read Status Enhanced behavior and timings. The plane and die address must be specified in
the command sequence in order to retrieve the status of the die and the plane of interest.
Refer to Table 3.5 for specific Status Register definitions. The command register remains in Status Read mode until further
commands are issued.
The Status Register is dynamic; the user is not required to toggle RE# / CE# to update it.
Document Number: 002-00676 Rev. *T
Page 22 of 73
S34ML01G1
S34ML02G1, S34ML04G1
3.11
Read Status Register Field Definition
Table 3.5 below lists the meaning of each bit of the Read Status Register and Read Status Enhanced (S34ML02G1 and
S34ML04G1).
Table 3.5 Status Register Coding
ID
Page
Program /
Page
Reprogram
Block Erase
Read
Read Cache
Cache
Program /
Cache
Reprogram
Coding
0
Pass / Fail
Pass / Fail
NA
NA
Pass / Fail
N Page
Pass: 0
Fail: 1
1
NA
NA
NA
NA
Pass / Fail
N - 1 Page
Pass: 0
Fail: 1
2
NA
NA
NA
NA
NA
—
3
NA
NA
NA
NA
NA
—
4
NA
NA
NA
NA
NA
—
5
Ready / Busy
Ready / Busy
Ready / Busy
Ready / Busy
Ready / Busy
Internal Data Operation
Active: 0
Idle: 1
6
Ready / Busy
Ready / Busy
Ready / Busy
Ready / Busy
Ready / Busy
Ready / Busy
Busy: 0
Ready: 1
7
Write Protect
Write Protect
NA
NA
Write Protect
Protected: 0
Not Protected: 1
3.12
Reset
The Reset feature is executed by writing FFh to the command register. If the device is in the Busy state during random read,
program, or erase mode, the Reset operation will abort these operations. The contents of memory cells being altered are no longer
valid, as the data may be partially programmed or erased. The command register is cleared to wait for the next command, and the
Status Register is cleared to value E0h when WP# is high or value 60h when WP# is low. If the device is already in reset state a new
Reset command will not be accepted by the command register. The R/B# pin transitions to low for tRST after the Reset command is
written. Refer to Figure 6.24 on page 50 for further details. The Status Register can also be read to determine the status of a Reset
operation.
3.13
Read Cache
Read Cache can be used to increase the read operation speed, as defined in Section 3.1 on page 15, and it cannot cross a block
boundary. As soon as the user starts to read one page, the device automatically loads the next page into the cache register. Serial
data output may be executed while data in the memory is read into the cache register. Read Cache is initiated by the Page Read
sequence (00-30h) on a page M.
After random access to the first page is complete (R/B# returned to high, or Read Status Register I/O6 switches to high), two
command sequences can be used to continue read cache:
Read Cache (command ‘31h’ only): once the command is latched into the command register (see Figure 6.26 on page 51),
device goes busy for a short time (tCBSYR), during which data of the first page is transferred from the data register to the
cache register. At the end of this phase, the cache register data can be output by toggling RE# while the next page (page
address M+1) is read from the memory array into the data register.
Read Cache Enhanced (sequence ‘00h’ ‘31’): once the command is latched into the command register
(see Figure 6.27 on page 52), device goes busy for a short time (tCBSYR), during which data of the first page is transferred
from the data register to the cache register. At the end of this phase, cache register data can be output by toggling RE#
while page N is read from the memory array into the data register.
Note: The S34ML01G1 device does not support Read Cache Enhanced.
Document Number: 002-00676 Rev. *T
Page 23 of 73
S34ML01G1
S34ML02G1, S34ML04G1
Subsequent pages are read by issuing additional Read Cache or Read Cache Enhanced command sequences. If serial data output
time of one page exceeds random access time (tR), the random access time of the next page is hidden by data downloading of the
previous page.
On the other hand, if 31h is issued prior to completing the random access to the next page, the device will stay busy as long as
needed to complete random access to this page, transfer its contents into the cache register, and trigger the random access to the
following page.
To terminate the Read Cache operation, 3Fh command should be issued (see Figure 6.28 on page 52). This command transfers
data from the data register to the cache register without issuing next page read.
During the Read Cache operation, the device doesn't allow any other command except for 00h, 31h, 3Fh, Read SR, or Reset (FFh).
To carry out other operations, Read Cache must be terminated by the Read Cache End command (3Fh) or the device must be reset
by issuing FFh.
Read Status command (70h) may be issued to check the status of the different registers and the busy/ready status of the cached
read operations.
The Cache-Busy status bit I/O6 indicates when the cache register is ready to output new data.
The status bit I/O5 can be used to determine when the cell reading of the current data register contents is complete.
Note: The Read Cache and Read Cache End commands reset the column counter, thus, when RE# is toggled to output the data of
a given page, the first output data is related to the first byte of the page (column address 00h). Random Data Output command can
be used to switch column address.
3.14
Cache Program
Cache Program can improve the program throughput by using the cache register. The Cache Program operation cannot cross a
block boundary. The cache register allows new data to be input while the previous data that was transferred to the data register is
programmed into the memory array.
After the serial data input command (80h) is loaded to the command register, followed by five cycles of address, a full or partial page
of data is latched into the cache register.
Once the cache write command (15h) is loaded to the command register, the data in the cache register is transferred into the data
register for cell programming. At this time the device remains in the Busy state for a short time (tCBSYW). After all data of the cache
register is transferred into the data register, the device returns to the Ready state and allows loading the next data into the cache
register through another Cache Program command sequence (80h-15h).
The Busy time following the first sequence 80h - 15h equals the time needed to transfer the data from the cache register to the data
register. Cell programming the data of the data register and loading of the next data into the cache register is consequently
processed through a pipeline model.
In case of any subsequent sequence 80h - 15h, transfer from the cache register to the data register is held off until cell programming
of current data register contents is complete; till this moment the device will stay in a busy state (tCBSYW).
Read Status commands (70h or 78h) may be issued to check the status of the different registers, and the pass/fail status of the
cached program operations.
The Cache-Busy status bit I/O6 indicates when the cache register is ready to accept new data.
The status bit I/O5 can be used to determine when the cell programming of the current data register contents is complete.
The Cache Program error bit I/O1 can be used to identify if the previous page (page N-1) has been successfully
programmed or not in a Cache Program operation. The status bit is valid upon I/O6 status bit changing to 1.
The error bit I/O0 is used to identify if any error has been detected by the program/erase controller while programming page
N. The status bit is valid upon I/O5 status bit changing to 1.
I/O1 may be read together with I/O0.
If the system monitors the progress of the operation only with R/B#, the last page of the target program sequence must be
programmed with Page Program Confirm command (10h). If the Cache Program command (15h) is used instead, the status bit I/O5
Document Number: 002-00676 Rev. *T
Page 24 of 73
S34ML01G1
S34ML02G1, S34ML04G1
must be polled to find out if the last programming is finished before starting any other operation. See Table 3.5 on page 23 and
Figure 6.29 on page 53 for more details.
If a Cache Program operation is interrupted by hardware reset, power failure or other means, the host must ensure that the
interrupted pages are not used for further reading or programming operations until the next uninterrupted block erases are complete
for the applicable blocks.
3.15
Multiplane Cache Program — S34ML02G1 and S34ML04G1
The Multiplane Cache Program enables high program throughput by programming two pages in parallel, while exploiting the data
and cache registers of both planes to implement cache.
The command sequence can be summarized as follows:
Serial Data Input command (80h), followed by the five cycle address inputs and then serial data for the 1st page. Address
for this page must be within 1st plane (PLA0 = 0). The data of 1st page other than those to be programmed do not need to
be loaded. The device supports Random Data Input exactly like Page Program operation.
The Dummy Page Program Confirm command (11h) stops 1st page data input and the device becomes busy for a short
time (tDBSY).
Once device returns to ready again, 81h command must be issued, followed by 2nd page address
(5 cycles) and its serial data input. Address for this page must be within 2nd plane (PLA0 = 1). The data of 2nd page other
than those to be programmed do not need to be loaded.
Cache Program confirm command (15h). Once the cache write command (15h) is loaded to the command register, the data
in the cache registers is transferred into the data registers for cell programming. At this time the device remains in the Busy
state for a short time (tCBSYW). After all data from the cache registers are transferred into the data registers, the device
returns to the Ready state, and allows loading the next data into the cache register through another Cache Program
command sequence.
The sequence 80h-...- 11h...-...81h...-...15h can be iterated, and each time the device will be busy for the tCBSYW time needed to
complete programming the current data register contents, and transferring the new data from the cache registers. The sequence to
end Multiplane Cache Program is 80h-...- 11h...-...81h...-...10h.
The Multiplane Cache Program is available only within two paired blocks in separate planes. Figure 6.30 on page 54 shows the
legacy protocol for the Multiplane Cache Program operation. In this case, the block address bits for the first plane are all zero and
the second address issued selects the block for both planes. Figure 6.31 on page 55 shows the ONFI protocol for the Multiplane
Cache Program operation. For both addresses issued in this protocol, the block address bits must be the same except for the bit(s)
that select the plane.
The user can check operation status by R/B# pin or Read Status Register commands (70h or 78h). If the user opts for 70h, Read
Status Register will provide “global” information about the operation in the two planes.
I/O6 indicates when both cache registers are ready to accept new data.
I/O5 indicates when the cell programming of the current data registers is complete.
I/O1 identifies if the previous pages in both planes (pages N-1) have been successfully programmed or not. This status bit
is valid upon I/O6 status bit changing to 1.
I/O0 identifies if any error has been detected by the program/erase controller while programming the two pages N. This
status bit is valid upon I/O5 status bit changing to 1.
See Table 3.5 on page 23 for more details.
If the system monitors the progress of the operation only with R/B#, the last pages of the target program sequence must be
programmed with Page Program Confirm command (10h). If the Cache Program command (15h) is used instead, the status bit I/O5
must be polled to find out if the last programming is finished before starting any other operation. Refer to Section 3.9 on page 22 for
further information.
If a Multiplane Cache Program operation is interrupted by hardware reset, power failure or other means, the host must ensure that
the interrupted pages are not used for further reading or programming operations until the next uninterrupted block erases are
complete for the applicable blocks.
Document Number: 002-00676 Rev. *T
Page 25 of 73
S34ML01G1
S34ML02G1, S34ML04G1
3.16
Read ID
The device contains a product identification mode, initiated by writing 90h to the command register, followed by an address input of
00h.
Note: If you want to execute Read Status command (0x70) after Read ID sequence, you should input dummy command (0x00)
before Read Status command (0x70).
For the S34ML02G1 and S34ML04G1 devices, five read cycles sequentially output the manufacturer code (01h), and the device
code and 3rd, 4th, and 5th cycle ID, respectively. For the S34ML01G1 device, four read cycles sequentially output the manufacturer
code (01h), device id (F1h), 3rd cycle (00h), and 4th cycle ID of 1Dh respectively. The command register remains in Read ID mode
until further commands are issued to it. Figure 6.32 on page 56 shows the operation sequence, while Table 3.6 to Table 3.11 explain
the byte meaning.
Table 3.6 Read ID for Supported Configurations
Density
Org
VCC
1 Gb
2 Gb
×8
4 Gb
1st
2nd
3rd
4th
01h
F1h
00h
1Dh
5th
—
01h
DAh
90h
95h
44h
01h
DCh
90h
95h
54h
3.3V
1 Gb
2 Gb
×16
4 Gb
01h
C1h
00h
5Dh
—
01h
CAh
90h
D5h
44h
01h
CCh
90h
D5h
54h
Table 3.7 Read ID Bytes
Device Identifier Byte
Description
1st
Manufacturer Code
2nd
Device Identifier
3rd
Internal chip number, cell type, etc.
4th
Page Size, Block Size, Spare Size, Serial Access Time, Organization
5th (S34ML02G1, S34ML04G1)
ECC, Multiplane information
Document Number: 002-00676 Rev. *T
Page 26 of 73
S34ML01G1
S34ML02G1, S34ML04G1
3rd ID Data
Table 3.8 Read ID Byte 3 Description
Description
Internal Chip Number
I/O7
I/O6
I/O5 I/O4
I/O3 I/O2
00
2
01
4
10
8
Cell type
11
2-level cell
00
4-level cell
01
8-level cell
10
16-level cell
Number of simultaneously
programmed pages
Interleave program
Between multiple chips
Cache Program
I/O1 I/O0
1
11
1
00
2
01
4
10
8
11
Not supported
0
Supported
1
Not supported
0
Supported
1
4th ID Data
Table 3.9 Read ID Byte 4 Description — S34ML01G1
Description
Page Size
(without spare area)
I/O7
I/O6
I/O5 I/O4
I/O3
I/O2
00
2 kB
01
4 kB
10
8 kB
Block Size
(without spare area)
Spare Area Size
(byte / 512 byte)
Serial Access Time
I/O1 I/O0
1 kB
11
64 kB
00
128 kB
01
256 kB
10
512 kB
11
8
0
16
1
45 ns
0
0
25 ns
0
1
Reserved
1
0
Reserved
1
1
×8
0
×16
1
Organization
Document Number: 002-00676 Rev. *T
Page 27 of 73
S34ML01G1
S34ML02G1, S34ML04G1
Table 3.10 Read ID Byte 4 Description — S34ML02G1 and S34ML04G1
Description
Page Size
(without spare area)
I/O7
I/O6
I/O5 I/O4
I/O3
I/O2
00
2 kB
01
4 kB
10
8 kB
Block Size
(without spare area)
Spare Area Size
(byte / 512 byte)
Serial Access Time
I/O1 I/O0
1 kB
11
64 kB
00
128 kB
01
256 kB
10
512 kB
11
8
0
16
1
50 ns / 30 ns
0
0
25 ns
1
0
Reserved
0
1
Reserved
1
1
×8
0
×16
1
Organization
5th ID Data
Table 3.11 Read ID Byte 5 Description — S34ML02G1 and S34ML04G1
Description
Plane Number
Plane Size
(without spare area)
I/O7
I/O3 I/O2
00
2
01
4
10
8
11
64 Mb
000
128 Mb
001
256 Mb
010
512 Mb
011
1 Gb
100
2 Gb
101
4 Gb
Reserved
3.17
I/O6 I/O5 I/O4
1
I/O1
I/O0
0
0
110
0
Read ID2
The device contains an alternate identification mode, initiated by writing 30h-65h-00h to the command register, followed by address
inputs, followed by command 30h. The address for S34ML01G1 will be
00h-02h-02h-00h. The address for S34ML02G1 and S34ML04G1 will be 00h-02h-02h-00h-00h. The ID2 data can then be read from
the device by pulsing RE#. The command register remains in Read ID2 mode until further commands are issued to it. Figure 6.33
on page 56 shows the Read ID2 command sequence. Read ID2 values are all 0xFs, unless specific values are requested when
ordering from Cypress.
3.18
Read ONFI Signature
To retrieve the ONFI signature, the command 90h together with an address of 20h shall be entered (i.e. it is not valid to enter an
address of 00h and read 36 bytes to get the ONFI signature). The ONFI signature is the ASCII encoding of 'ONFI' where 'O' = 4Fh,
'N' = 4Eh, 'F' = 46h, and 'I' = 49h. Reading beyond four bytes yields indeterminate values. Figure 6.34 on page 57 shows the
operation sequence.
Document Number: 002-00676 Rev. *T
Page 28 of 73
S34ML01G1
S34ML02G1, S34ML04G1
3.19
Read Parameter Page
The device supports the ONFI Read Parameter Page operation, initiated by writing ECh to the command register, followed by an
address input of 00h. The host may monitor the R/B# pin or wait for the maximum data transfer time (tR) before reading the
Parameter Page data. The command register remains in Parameter Page mode until further commands are issued to it. If the Status
Register is read to determine when the data is ready, the Read Command (00h) must be issued before starting read cycles.
Figure 6.35 on page 57 shows the operation sequence, while Table 3.12 explains the parameter fields.
For ×16 devices, the upper eight I/Os are not used and are 0xFF.
Note: For 41nm 2Gb/4Gb Cypress NAND, for a particular condition, the Read Parameter Page command does not give the correct
values. To overcome this issue, the host must issue a Reset command before the Read Parameter Page command. Issuance of
Reset before the Read Parameter Page command will provide the correct values and will not output 00h values. This does not apply
to 48nm 1Gb.
Table 3.12 Parameter Page Description (Sheet 1 of 3)
Byte
O/M
Description
Values
Revision Information and Features Block
0-3
4-5
6-7
8-9
M
Parameter page signature
Byte 0: 4Fh, “O”
Byte 1: 4Eh, “N”
Byte 2: 46h, “F”
Byte 3: 49h, “I”
4Fh, 4Eh, 46h, 49h
M
Revision number
2-15
Reserved (0)
1
1 = supports ONFI version 1.0
0
Reserved (0)
02h, 00h
M
Features supported
5-15
Reserved (0)
4
1 = supports odd to even page Copyback
3
1 = supports interleaved operations
2
1 = supports non-sequential page programming
1
1 = supports multiple LUN operations
0
1 = supports 16-bit data bus width
S34ML01G100 (×8): 14h, 00h
S34ML02G100 (×8): 1Ch, 00h
S34ML04G100 (×8): 1Ch, 00h
S34ML01G104 (×16): 15h, 00h
S34ML02G104 (×16): 1Dh, 00h
S34ML04G104 (×16): 1Dh, 00h
M
Optional commands supported
6-15
Reserved (0)
5
1 = supports Read Unique ID
4
1 = supports Copyback
3
1 = supports Read Status Enhanced
2
1 = supports Get Features and Set Features
1
1 = supports Read Cache commands
0
1 = supports Page Cache Program command
S34ML01G1: 13h, 00h
S34ML02G1: 1Bh, 00h
S34ML04G1: 1Bh, 00h
Reserved (0)
00h
10-31
Manufacturer Information Block
32-43
M
Device manufacturer (12 ASCII characters)
53h, 50h, 41h, 4Eh, 53h, 49h,
4Fh, 4Eh, 20h, 20h, 20h, 20h
S34ML01G1: 53h, 33h, 34h,
4Dh, 4Ch, 30h, 31h, 47h, 31h,
20h, 20h, 20h, 20h, 20h, 20h,
20h, 20h, 20h, 20h, 20h
44-63
M
Device model (20 ASCII characters)
S34ML02G1: 53h, 33h, 34h,
4Dh, 4Ch, 30h, 32h, 47h, 31h,
20h, 20h, 20h, 20h, 20h, 20h,
20h, 20h, 20h, 20h, 20h
S34ML04G1: 53h, 33h, 34h,
4Dh, 4Ch, 30h, 34h, 47h, 31h,
20h, 20h, 20h, 20h, 20h, 20h,
20h, 20h, 20h, 20h, 20h
64
M
JEDEC manufacturer ID
01h
65-66
O
Date code
00h
Document Number: 002-00676 Rev. *T
Page 29 of 73
S34ML01G1
S34ML02G1, S34ML04G1
Table 3.12 Parameter Page Description (Sheet 2 of 3)
Byte
O/M
67-79
Description
Reserved (0)
Values
00h
Memory Organization Block
80-83
M
Number of data bytes per page
00h, 08h, 00h, 00h
84-85
M
Number of spare bytes per page
40h, 00h
86-89
M
Number of data bytes per partial page
00h, 02h, 00h, 00h
90-91
M
Number of spare bytes per partial page
10h, 00h
92-95
M
Number of pages per block
40h, 00h, 00h, 00h
96-99
M
Number of blocks per logical unit (LUN)
S34ML01G1: 00h, 04h, 00h, 00h
S34ML02G1: 00h, 08h, 00h, 00h
S34ML04G1: 00h, 10h, 00h, 00h
100
M
Number of logical units (LUNs)
01h
101
M
Number of address cycles
4-7
Column address cycles
0-3
Row address cycles
S34ML01G1: 22h
S34ML02G1: 23h
S34ML04G1: 23h
102
M
Number of bits per cell
01h
103-104
M
Bad blocks maximum per LUN
S34ML01G1: 14h, 00h
S34ML02G1: 28h, 00h
S34ML04G1: 50h, 00h
105-106
M
Block endurance
01h, 05h
107
M
Guaranteed valid blocks at beginning of target
01h
108-109
M
Block endurance for guaranteed valid blocks
01h, 03h
110
M
Number of programs per page
04h
111
M
Partial programming attributes
5-7
Reserved
4
1 = partial page layout is partial page data followed by
partial page spare
1-3
Reserved
0
1 = partial page programming has constraints
00h
112
M
Number of bits ECC correctability
01h
113
M
Number of interleaved address bits
4-7
Reserved (0)
0-3
Number of interleaved address bits
S34ML01G1: 00h
S34ML02G1: 01h
S34ML04G1: 01h
O
Interleaved operation attributes
4-7
Reserved (0)
3
Address restrictions for program cache
2
1 = program cache supported
1
1 = no block address restrictions
0
Overlapped / concurrent interleaving support
S34ML01G1: 00h
S34ML02G1: 04h
S34ML04G1: 04h
Reserved (0)
00h
114
115-127
Electrical Parameters Block
128
129-130
M
I/O pin capacitance
0Ah
M
Timing mode support
6-15
Reserved (0)
5
1 = supports timing mode 5
4
1 = supports timing mode 4
3
1 = supports timing mode 3
2
1 = supports timing mode 2
1
1 = supports timing mode 1
0
1 = supports timing mode 0, shall be 1
1Fh, 00h
Document Number: 002-00676 Rev. *T
Page 30 of 73
S34ML01G1
S34ML02G1, S34ML04G1
Table 3.12 Parameter Page Description (Sheet 3 of 3)
Byte
O/M
Description
Values
131-132
O
Program cache timing mode support
6-15
Reserved (0)
5
1 = supports timing mode 5
4
1 = supports timing mode 4
3
1 = supports timing mode 3
2
1 = supports timing mode 2
1
1 = supports timing mode 1
0
1 = supports timing mode 0
133-134
M
tPROG Maximum page program time (µs)
BCh, 02h
135-136
M
tBERS Maximum block erase time (µs)
S34ML01G1: B8h, 0Bh
S34ML02G1: 10h, 27h
S34ML04G1: 10h, 27h
137-138
M
tR Maximum page read time (µs)
19h, 00h
139-140
M
tCCS Minimum Change Column setup time (ns)
64h, 00h
Reserved (0)
00h
141-163
1Fh, 00h
Vendor Block
164-165
M
166-253
254-255
M
Vendor specific Revision number
00h
Vendor specific
00h
Integrity CRC
S34ML01G100 (×8): FFh, 63h
S34ML02G100 (×8): 3Bh, C5h
S34ML04G100 (×8): 45h, 8Eh
S34ML01G104 (×16): 8Dh, 15h
S34ML02G104 (×16): 49h, B3h
S34ML04G104 (×16): 37h, F8h
Redundant Parameter Pages
256-511
M
Value of bytes 0-255
512-767
M
Value of bytes 0-255
Repeat Value of bytes 0-255
Repeat Value of bytes 0-255
768+
O
Additional redundant parameter pages
FFh
Note:
1. O” Stands for Optional, “M” for Mandatory.
3.20
One-Time Programmable (OTP) Entry
The device contains a one-time programmable (OTP) area, which is accessed by writing 29h-17h-04h-19h to the command register.
The device is then ready to accept Page Read and Page Program commands (refer to Page Read and Page Program on page 15).
The OTP area is of a single erase block size (64 pages), and hence only row addresses between 00h and 3Fh are allowed. The host
must issue the Reset command (refer to Reset on page 23) to exit the OTP area and access the normal flash array. The Block Erase
command is not allowed in the OTP area. Refer to Figure 6.36 on page 58 for more detail on the OTP Entry command sequence.
Note: The OTP feature in the S34ML01G1 does not have non-volatile protection.
4. Signal Descriptions
4.1
Data Protection and Power On / Off Sequence
The device is designed to offer protection from any involuntary program/erase during power-transitions. An internal voltage detector
disables all functions whenever VCC is below about 1.8V.
The power-up and power-down sequence is shown in Figure 6.37 on page 58.
The Ready/Busy signal shall be valid within 100 µs after the power supplies have reached the minimum values (as specified on),
and shall return to one within 5 ms (max).
Document Number: 002-00676 Rev. *T
Page 31 of 73
S34ML01G1
S34ML02G1, S34ML04G1
During this busy time, the device executes the initialization process (cam reading), and dissipates a current ICC0 (30 mA max), in
addition, it disregards all commands excluding Read Status Register (70h).
At the end of this busy time, the device defaults into “read setup”, thus if the user decides to issue a page read command, the 00h
command may be skipped.
The WP# pin provides hardware protection and is recommended to be kept at VIL during power-up and power-down. A recovery time
of minimum 100 µs is required before the internal circuit gets ready for any command sequences as shown in Figure 6.37
on page 58. The two-step command sequence for
program/erase provides additional software protection.
4.2
Ready/Busy
The Ready/Busy output provides a method of indicating the completion of a page program, erase, copyback, or read completion.
The R/B# pin is normally high and goes to low when the device is busy (after a reset, read, program, or erase operation). It returns to
high when the internal controller has finished the operation. The pin is an open-drain driver thereby allowing two or more R/B#
outputs to be Or-tied. Because the pull-up resistor value is related to tr (R/B#) and the current drain during busy (ibusy), and output
load capacitance is related to tf an appropriate value can be obtained with the reference chart shown in Figure 4.1.
For example, for a particular system with 20 pF of output load, tf from VCC to VOL at 10% to 90% will be 10 ns, whereas for a
particular load of 50 pF, Cypress measured it to be 20 ns as shown in Figure 4.1.
Figure 4.1 Ready/Busy Pin Electrical Application
Rp
Vcc
ibusy
Ready
VCC
R/B#
open drain output
VOH
VOL : 0.4V, VOH : 2.4V
CL
VOL
Busy
tf
tr
GND
Device
Rp vs. tr, tf and Rp vs. ibusy
@ Vcc = 3.3V, Ta = 25°C, CL=50 pF
ibusy [A]
300n
3m
200
200n
2m
1.2
100n
Legend
= tr (ns)
2.4
100
= ibusy (mA)
= tf (ns)
150
0.8
50
1m
0.6
20
20
1k
2k
20
20
tr,tf [s]
3k
4k
Rp (ohm)
Rp value guidence
Rp (min.) =
Vcc (Max.) - VOL (Max.)
I OL + ∑I
L
=
3.2V
8mA + ∑I L
where I L is the sum of the input currents of all devices tied to the R/B# pin.
Rp(max) is determined by maximum permissible limit of tr.
Document Number: 002-00676 Rev. *T
Page 32 of 73
S34ML01G1
S34ML02G1, S34ML04G1
4.3
Write Protect Operation
Erase and program operations are aborted if WP# is driven low during busy time, and kept low for about
100 ns. Switching WP# low during this time is equivalent to issuing a Reset command (FFh). The contents of memory cells being
altered are no longer valid, as the data will be partially programmed or erased. The
R/B# pin will stay low for tRST (similarly to Figure 6.24 on page 50). At the end of this time, the command register is ready to process
the next command, and the Status Register bit I/O6 will be cleared to 1, while I/O7 value will be related to the WP# value. Refer to
Table 3.5 on page 23 for more information on device status.
Erase and program operations are enabled or disabled by setting WP# to high or low respectively, prior to issuing the setup
commands (80h or 60h). The level of WP# shall be set tWW ns prior to raising the WE# pin for the set up command, as explained in
Figure 6.38 and Figure 6.39 on page 59.
Figure 4.2 WP# Low Timing Requirements during Program/Erase Command Sequence
WE#
I/O[7:0]
Valid
WP#
> 100 ns
Document Number: 002-00676 Rev. *T
Sequence
Aborted
Page 33 of 73
S34ML01G1
S34ML02G1, S34ML04G1
5. Electrical Characteristics
5.1
Valid Blocks
Table 5.1 Valid Blocks
Symbol
Min
Typ
Max
Unit
S34ML01G1
Device
NVB
1004
—
1024
Blocks
S34ML02G1
NVB
2008
—
2048
Blocks
S34ML04G1
NVB
4016
—
4096
Blocks
5.2
Absolute Maximum Ratings
Table 5.2 Absolute Maximum Ratings
Parameter
Symbol
Value
Unit
TA
-40 to +85
°C
Temperature under Bias
TBIAS
-50 to +125
°C
Storage Temperature
TSTG
-65 to +150
°C
Ambient Operating Temperature (Industrial Temperature Range)
Input or Output Voltage
Supply Voltage
VIO (2)
-0.6 to +4.6
V
VCC
-0.6 to +4.6
V
Notes:
1. Except for the rating “Operating Temperature Range”, stresses above those listed in the table Absolute Maximum Ratings “Absolute Maximum Ratings” may cause
permanent damage to the device. These are stress ratings only and operation of the device at these or any other conditions above those indicated in the Operating
sections of this specification is not implied. Exposure to Absolute Maximum Rating conditions for extended periods may affect device reliability.
2. Minimum Voltage may undershoot to -2V during transition and for less than 20 ns during transitions.
3. Maximum Voltage may overshoot to VCC+2.0V during transition and for less than 20 ns during transitions.
5.3
Recommended Operating Conditions
Table 5.3 Recommended Operating Conditions
Parameter
Symbol
Min
Typ
Max
Units
Vcc Supply Voltage
Vcc
2.7
3.3
3.6
V
Ground Supply Voltage
Vss
0
0
0
V
5.4
AC Test Conditions
Table 5.4 AC Test Conditions
Parameter
Input Pulse Levels
Input Rise And Fall Times
Input And Output Timing Levels
Output Load (2.7V - 3.6V)
Document Number: 002-00676 Rev. *T
Value
0.0V to VCC
5 ns
VCC / 2
1 TTL Gate and CL = 50 pF
Page 34 of 73
S34ML01G1
S34ML02G1, S34ML04G1
5.5
AC Characteristics
Table 5.5 AC Characteristics
Symbol
Min
Max
Unit
ALE to RE# delay
Parameter
tAR
10
—
ns
ALE hold time
tALH
5
—
ns
ALE setup time
tALS
10
—
ns
Address to data loading time
tADL
70
—
ns
CE# low to RE# low
tCR
10
—
ns
CE# hold time
tCH
5
—
ns
CE# high to output High-Z
tCHZ
—
30
ns
CLE hold time
tCLH
5
—
ns
CLE to RE# delay
tCLR
10
—
ns
tCLS
10
—
ns
CE# access time
tCEA (4)
—
25
ns
CE# high to output hold
tCOH (3)
15
—
ns
tCSD
10
—
ns
CE# setup time
tCS
20
—
ns
Data hold time
tDH
5
—
ns
Data setup time
tDS
10
—
ns
Data transfer from cell to register
tR
—
25
µs
CLE setup time
CE# high to ALE or CLE don't care
Output High-Z to RE# low
tIR
0
—
ns
Read cycle time
tRC
25
—
ns
RE# access time
tREA
—
20
ns
RE# high hold time
tREH
10
—
ns
tRHOH (3)
15
—
ns
tRHW
100
—
ns
RE# high to output High-Z
tRHZ
—
100
ns
RE# low to output hold
tRLOH
5
—
ns
RE# pulse width
tRP
12
—
ns
Ready to RE# low
tRR
20
—
ns
Device resetting time (Read/Program/Erase)
tRST
—
5/10/500
µs
WE# high to busy
tWB
—
100
ns
RE# high to output hold
RE# high to WE# low
Write cycle time
tWC
25
—
ns
WE# high hold time
tWH
10
—
ns
WE# high to RE# low
tWHR
60
—
ns
WE# pulse width
tWP
12
—
ns
Write protect time
tWW
100
—
ns
Notes:
1. The time to Ready depends on the value of the pull-up resistor tied to R/B# pin.
2. If Reset Command (FFh) is written at Ready state, the device goes into Busy for maximum 5 µs.
3. CE# low to high or RE# low to high can be at different times and produce three cases. Depending on which signal comes high first, either tCOH or tRHOH will be met.
4. During data output, tCEA depends partly on tCR (CE# low to RE# low). If tCR exceeds the minimum value specified, then the maximum time for tCEA may also be
exceeded (tCEA = tCR + tREA).
Document Number: 002-00676 Rev. *T
Page 35 of 73
S34ML01G1
S34ML02G1, S34ML04G1
5.6
DC Characteristics
Table 5.6 DC Characteristics and Operating Conditions
Parameter
Symbol
Power-On Current
(S34ML02G1, S34ML04G1)
ICC0
Sequential
Read
ICC1
Program
ICC2
Operating Current
Erase
ICC3
Standby Current, (TTL)
ICC4
Standby Current, (CMOS)
ICC5
Test Conditions
Min
Typ
Max
Units
—
15
30
mA
—
15
30
mA
Normal (S34ML01G1)
—
15
30
mA
Normal (S34ML02G1)
—
15
30
mA
Normal (S34ML04G1)
—
—
30
mA
Cache (S34ML02G1)
—
20
40
mA
Cache (S34ML04G1)
—
—
40
mA
— (S34ML01G1)
—
15
30
mA
— (S34ML02G1)
—
—
30
mA
— (S34ML04G1)
—
15
30
mA
—
—
1
mA
—
10
50
µA
Power-Up Current
(Refer to Section 4.1)
tRC = see Table 5.5
CE#=VIL, IOUT = 0 mA
CE# = VIH,
WP# = 0V/Vcc
CE# = VCC –0.2,
WP# = 0/VCC
Input Leakage Current
ILI
VIN = 0 to 3.6V
—
—
±10
µA
Output Leakage Current
ILO
VOUT = 0 to 3.6V
—
—
±10
µA
Input High Voltage
VIH
—
VCC x 0.8
—
VCC + 0.3
V
Input Low Voltage
VIL
—
-0.3
—
VCC x 0.2
V
Output High Voltage
VOH
IOH = –400 µA
2.4
—
—
V
Output Low Voltage
VOL
IOL = 2.1 mA
—
—
0.4
V
IOL(R/B#)
VOL = 0.4V
8
10
—
mA
VLKO
—
—
1.8
—
V
Output Low Current (R/B#)
Erase and Program Lockout Voltage
Notes:
1. All VCC pins, and VSS pins respectively, are shorted together.
2. Values listed in this table refer to the complete voltage range for VCC and to a single device in case of device stacking.
3. All current measurements are performed with a 0.1 µF capacitor connected between the VCC Supply Voltage pin and the VSS Ground pin.
4. Standby current measurement can be performed after the device has completed the initialization process at power up. Refer to Section 4.1 for more details.
5.7
Pin Capacitance
Table 5.7 Pin Capacitance (TA = 25°C, f=1.0 MHz)
Parameter
Symbol
Test Condition
Min
Max
Unit
Input
CIN
VIN = 0V
—
10
pF
Input / Output
CIO
VIL = 0V
—
10
pF
Note:
1. For the stacked devices version the Input is 10 pF x [number of stacked chips] and the Input/Output is 10 pF x [number of stacked chips].
Document Number: 002-00676 Rev. *T
Page 36 of 73
S34ML01G1
S34ML02G1, S34ML04G1
5.8
Program / Erase Characteristics
Table 5.8 Program / Erase Characteristics
Parameter
Description
Min
Typ
Max
Unit
tPROG
—
200
700
µs
µs
Program Time / Multiplane Program Time (2)
tDBSY
—
0.5
1
tCBSYW
—
5
tPROG
µs
NOP
—
—
4
Cycle
tBERS
—
3.5
10
ms
Block Erase Time (S34ML01G1)
tBERS
—
2
3
ms
Read Cache busy time
tCBSYR
—
3
tR
µs
Dummy Busy Time for Multiplane Program (S34ML02G1, S34ML04G1)
Cache Program short busy time (S34ML02G1, S34ML04G1)
Number of partial Program Cycles in the same page
Main + Spare
Block Erase Time / Multiplane Erase Time (S34ML02G1, S34ML04G1)
Notes:
1. Typical program time is defined as the time within which more than 50% of the whole pages are programmed (VCC = 3.3V, 25°C).
2. Copy Back Read and Copy Back Program for a given plane must be between odd address pages or between even address pages for the device to meet the program
time (tPROG) specification. Copy Back Program may not meet this specification when copying from an odd address page (source page) to an even address page
(target page) or from an even address page (source page) to an odd address page (target page).
6. Timing Diagrams
6.1
Command Latch Cycle
Command Input bus operation is used to give a command to the memory device. Commands are accepted with Chip Enable low,
Command Latch Enable High, Address Latch Enable low, and Read Enable High and latched on the rising edge of Write Enable.
Moreover for commands that starts a modify operation (write/ erase) the Write Protect pin must be high.
Figure 6.1 Command Latch Cycle
CLE
tCLS
tCLH
tCS
tCH
CE#
tWP
WE#
tALS
tALH
ALE
tDS
I/Ox
tDH
Command
= Don’t Care
Document Number: 002-00676 Rev. *T
Page 37 of 73
S34ML01G1
S34ML02G1, S34ML04G1
6.2
Address Latch Cycle
Address Input bus operation allows the insertion of the memory address. To insert the 27 (×8 Device) addresses needed to access
the 1 Gb, four write cycles are needed. Addresses are accepted with Chip Enable low, Address Latch Enable High, Command Latch
Enable low, and Read Enable High and latched on the rising edge of Write Enable. Moreover, for commands that start a modify
operation (write/ erase) the Write Protect pin must be high.
Figure 6.2 Address Latch Cycle
tCLS
CLE
tCS
tWC
tWC
tWC
tWC
CE#
tWP
tWP
tWP
tWP
WE#
tWH
tALH
tALS
tALS
tWH
tALH
tALS
tWH
tALS tALH
tWH
tALH
tALS
tALH
ALE
tDH
tDH
tDH
tDS
Col.
Add2
Col.
Add1
I/Ox
tDH
tDS
tDS
tDS
Row.
Add2
Row.
Add1
tDH
tDS
Row.
Add3
= Don’t Care
6.3
Data Input Cycle Timing
Data Input bus operation allows the data to be programmed to be sent to the device. The data insertion is serially, and timed by the
Write Enable cycles. Data is accepted only with Chip Enable low, Address Latch Enable low, Command Latch Enable low, Read
Enable High, and Write Protect High and latched on the rising edge of Write Enable.
Figure 6.3 Input Data Latch Cycle
tCLH
CLE
tCH
CE#
tWC
tALS
ALE
tWP
tWP
WE#
tWH
tDS
I/Ox
tDH
Din 0
tWP
tWH
tDS
Din
tDH
tDS
tDH
Din final
= Don’t Care
Document Number: 002-00676 Rev. *T
Page 38 of 73
S34ML01G1
S34ML02G1, S34ML04G1
6.4
Data Output Cycle Timing (CLE=L, WE#=H, ALE=L, WP#=H)
Figure 6.4 Data Output Cycle Timing
tRC
tCHZ
CE#
tREH
tREA
RE#
tREA
tREA
tCOH
tRHZ
tRHZ
tRHOH
I/Ox
Dout
Dout
Dout
tRR
R/B#
Notes:
1. Transition is measured at ± 200 mV from steady state voltage with load.
2. This parameter is sampled and not 100% tested.
3. tRHOH starts to be valid when frequency is lower than 33 MHz.
6.5
Data Output Cycle Timing (EDO Type, CLE=L, WE#=H, ALE=L)
Figure 6.5 Data Output Cycle Timing (EDO)
CE#
tCR
tRC
RE#
tRP
tCHZ
tCOH
tREH
tREA
I/Ox
tREA
tRLOH
Dout
tRHZ
tRHOH
Dout
tRR
R/B#
= Don’t Care
Notes:
1. Transition is measured at ± 200 mV from steady state voltage with load.
2. This parameter is sampled and not 100% tested.
3. tRLOH is valid when frequency is higher than 33 MHz.
4. tRHOH starts to be valid when frequency is lower than 33 MHz.
Document Number: 002-00676 Rev. *T
Page 39 of 73
S34ML01G1
S34ML02G1, S34ML04G1
6.6
Page Read Operation
Figure 6.6 Page Read Operation (Read One Page)
CLE
tCLR
CE#
tWC
WE#
tCSD
tWB
ALE
tR
RE#
I/Ox
tAR
tRC
tRHZ
tRR
00h
Col.
Add. 1
Col.
Add. 2
Column Address
Row
Add. 1
Row
Add. 2
Row
Add. 3
30h
Dout N
Dout
N +1
Dout
M
Row Address
R/B#
Busy
= Don’t Care
Note:
1. If Status Register polling is used to determine completion of the read operation, the Read Command (00h) must be issued before data can be read from the page
buffer.
Document Number: 002-00676 Rev. *T
Page 40 of 73
S34ML01G1
S34ML02G1, S34ML04G1
6.7
Page Read Operation (Interrupted by CE#)
Figure 6.7 Page Read Operation Interrupted by CE#
CLE
tCLR
CE#
tCSD
tCHZ
WE#
tCOH
tWB
tAR
ALE
tRC
tR
RE#
tRR
I/Ox
00h
Col.
Col.
Add. 1 Add. 2
Column Address
Row
Add. 1
Row
Add. 2
Row
Add. 3
Dout N
30h
Dout
N +1
Dout
N +2
Row Address
R/B#
Busy
Document Number: 002-00676 Rev. *T
= Don’t Care
Page 41 of 73
S34ML01G1
S34ML02G1, S34ML04G1
6.8
Page Read Operation Timing with CE# Don’t Care
Figure 6.8 Page Read Operation Timing with CE# Don’t Care
CE# don’t care
CE#
CLE
ALE
WE#
tRC
RE#
tRR
00h
I/Ox
Col.
Add. 1
Col.
Add. 2
Row
Add. 1
Row
Add. 2
Row
Add. 3
Dout
N
30h
Dout
N+1
Dout
N+2
Dout
N+3
Dout
N+4
Dout
N+5
Dout
M
Dout
M+1
Dout
M+2
tR
R/B#
: Don’t Care (VIH or VIL)
tCR
CE#
tREA
RE#
I/Ox
6.9
Dout
Page Program Operation
Figure 6.9 Page Program Operation
CLE
CE#
tWC
tWC
tWC
WE#
tADL
tWB
tPROG
tWHR
ALE
RE#
I/Ox
Col.
Row.
Col.
Row.
Row.
80h
Add2
Add3
Add1
Add2
Add1
Serial Data
Row Address
Input Command Column Address
Din
N
1 up to m byte
Serial Input
Din
M
10h
Program
Command
70h
I/O0
Read Status
Command
R/B#
I/O0=0 Successful Program
I/O0=1 Error in Program
= Don’t Care
Note:
1. tADL is the time from the WE# rising edge of final address cycle to the WE# rising edge of first data cycle.
Document Number: 002-00676 Rev. *T
Page 42 of 73
S34ML01G1
S34ML02G1, S34ML04G1
6.10
Page Program Operation Timing with CE# Don’t Care
Figure 6.10 Page Program Operation Timing with CE# Don’t Care
CE# don’t care
CE#
CLE
ALE
WE#
RE#
I/Ox
80h
Col.
Add. 1
Col.
Add. 2
Row
Add. 1
Row
Add. 2
Row
Add. 3
Din
N
Din
M
Din
N+1
Din
P
Din
R
Din
P+1
10h
: Don’t Care
tWP
WE#
6.11
tCH
tCS
CE#
Page Program Operation with Random Data Input
Figure 6.11 Random Data Input
CLE
CE#
tWC
tWC
tWC
WE#
tADL
tADL
tWB
tPROG
tWHR
ALE
RE#
I/Ox
80h
Serial Data
Input Command
Col.
Add1
Col.
Add2
Row
Add1
Column Address
Row
Add2
Row Address
Row
Add3
Din
N
Din
M
85h
Random Data
Input Command
Col.
Add1
Col.
Add2
Column Address
Din
J
Din
K
Serial Input
10h
Program
Command
70h
IO0
Read Status
Command
R/B#
= Don’t Care
Notes:
1. tADL is the time from the WE# rising edge of final address cycle to the WE# rising edge of first data cycle.
2. For EDC operation only one Random Data Input is allowed at each EDC Unit.
Document Number: 002-00676 Rev. *T
Page 43 of 73
S34ML01G1
S34ML02G1, S34ML04G1
6.12
Random Data Output In a Page
Figure 6.12 Random Data Output
CLE
tCLR
CE#
WE#
tWB
tAR
tWHR
tRHW
ALE
tRC
tR
tREA
RE#
tRR
00h
I/Ox
Col.
Col.
Add. 2
Add. 1
Column Address
Row
Row
Row
Add. 2 Add. 3
Add. 1
Row Address
Dout N
30h
Dout
N +1
Col.
Col.
Add. 2
Add. 1
Column Address
05h
E0h
Dout M
Dout
M +1
R/B#
= Don’t Care
Busy
6.13
Multiplane Page Program Operation — S34ML02G1 and S34ML04G1
Figure 6.13 Multiplane Page Program
CLE
CE#
tWC
WE#
tWB
tDBSY
tWB
tPROG
tWHR
ALE
RE#
I/Ox
tADL
tADL
80h
Col.
Add1
Col.
Add2
Row
Add1
Row Row
Add2 Add3
Serial Data
Column Address Page Row Address
Input Command
Din
N
Din
M
1 up to 2112 byte
Data Serial Input
81h
11h
Program
Command
(Dummy)
Col.
Add1
Col.
Add2
Row
Add1
Row
Add2
Row
Add3
Din
M
Din
N
10h
Program Confirm
Command (True)
70h
IO
Read Staus
Command
R/B#
Ex.) Address Restriction for Multiplane Page Program
I/O0~7
tPROG
tDBSY
R/B#
80h
Address & Data Input
Col Add 1,2 and Row Add 1,2,3
(2112 byte data)
11h
81h
(Note 1)
A0 ~ A11: Valid
A12 ~ A17: Fixed ‘Low’
A18: Fixed ‘Low’
A19 ~ A28: Fixed ‘Low’
Address & Data Input
10h
70h
Col Add 1,2 and Row Add 1,2,3
(2112 byte data)
A0 ~ A11: Valid
A12 ~ A17: Valid
A18: Fixed ‘High’
A19 ~ A28: Valid
Notes:
1. Any command between 11h and 81h is prohibited except 70h, 78h, and FFh.
2. A18 is the plane address bit for ×8 devices. A17 is the plane address bit for ×16 devices.
Document Number: 002-00676 Rev. *T
Page 44 of 73
S34ML01G1
S34ML02G1, S34ML04G1
Figure 6.14 Multiplane Page Program (ONFI 1.0 Protocol)
Cycle Type
CMD ADDR ADDR ADDR ADDR ADDR
DIN
DIN
DIN
DIN
CMD
D0A
D1A
...
DnA
11h
tADL
DQx
80h
C1A
C2A
R2A
R1A
R3A
tADL
tIPBSY
SR[6]
A
Cycle Type
CMD ADDR ADDR ADDR ADDR ADDR
DIN
DIN
DIN
DIN
CMD
D0B
D1B
...
DnB
10h
tADL
80h
DQx
C1B
C2B
R1B
R2B
R3B
tADL
tPROG
SR[6]
Notes:
1. C1A-C2A Column address for page A. C1A is the least significant byte.
2. R1A-R3A Row address for page A. R1A is the least significant byte.
3. D0A-DnA Data to program for page A.
4. C1B-C2B Column address for page B. C1B is the least significant byte.
5. R1B-R3B Row address for page B. R1B is the least significant byte.
6. D0B-DnB Data to program for page B.
7. The block address bits must be the same except for the bit(s) that select the plane.
6.14
Block Erase Operation
Figure 6.15 Block Erase Operation (Erase One Block)
CLE
CE#
tWC
WE#
tWB
tBERS
tWHR
ALE
RE#
I/Ox
60h
Row Add1 Row Add2 Row Add3
70h
D0h
I/O0
Row Address
BUSY
R/B#
Auto Block Erase
Setup Command
Erase Command
Read Status
Command
I/O0=0 Successful Erase
I/O0=1 Error in Erase
= Don’t Care
Document Number: 002-00676 Rev. *T
Page 45 of 73
S34ML01G1
S34ML02G1, S34ML04G1
6.15
Multiplane Block Erase — S34ML02G1 and S34ML04G1
Figure 6.16 Multiplane Block Erase
CLE
CE#
tWC
tWC
WE#
tWB
tWHR
tBERS
ALE
RE#
60h
I/Ox
60h
Row Add1 Row Add2 Row Add3
Row Add1 Row Add2 Row Add3
D0h
I/O0
70h
Row Address
Row Address
Busy
R/B#
Block Erase Setup Command1
Block Erase Setup Command2
Erase Confirm Command
Read Status Command
I/O 1 = 0 Successful Erase
I/O 1 = 1 Error in plane
Ex.) Address Restriction for Multiplane Block Erase Operation
R/B#
I/O0~7
tBERS
Address
60h
Address
60h
Row Add1,2,3
Row Add1,2,3
A12 ~ A17 : Fixed ‘Low’
A18
: Fixed ‘Low’
A19 ~ A28 : Fixed ‘Low’
A12 ~ A17 : Fixed ‘Low’
A18
: Fixed ‘High’
A19 ~ A28 : Valid
D0h
70h
Note:
1. A18 is the plane address bit for ×8 devices. A17 is the plane address bit for ×16 devices.
Figure 6.17 Multiplane Block Erase (ONFI 1.0 Protocol)
CLE
WE#
ALE
RE#
IOx
60h
R1 A
R2A
SR[6]
R3A D1h
60h
t
R1B
IEBSY
R2B
R3B
D0h
t
BERS
Notes:
1. R1A-R3A Row address for block on plane 0. R1A is the least significant byte.
2. R1B-R3B Row address for block on plane 1. R1B is the least significant byte.
3. The block address bits must be the same except for the bit(s) that select the plane.
Document Number: 002-00676 Rev. *T
Page 46 of 73
S34ML01G1
S34ML02G1, S34ML04G1
6.16
Copy Back Read with Optional Data Readout
Figure 6.18 Copy Back Read with Optional Data Readout
I/O
00h
Source
Add Inputs
35h
Data Outputs
Target
Add Inputs
85h
SR0/
EDC Reg
70h/
7Bh
10h
Read Status Register/
EDC Register
tR
(Read Busy time)
tPROG
(Program Busy time)
R/B#
Busy
6.17
Busy
Copy Back Program Operation With Random Data Input
Figure 6.19 Copy Back Program with Random Data Input
I/O
00h
Source
Add Inputs
35h
85h
Target
Add Inputs
Data
85h
2 Cycle
Add Inputs
Data
70h
10h
SR0
Read Status Register
Unlimited number of repetitions
R/B#
tR
(Read Busy time)
tPROG
(Program Busy time)
Busy
Document Number: 002-00676 Rev. *T
Busy
Page 47 of 73
S34ML01G1
S34ML02G1, S34ML04G1
6.18
Multiplane Copy Back Program — S34ML02G1 and S34ML04G1
Figure 6.20 Multiplane Copy Back Program
tR
tR
R/B#
I/Ox
00h
Add. (5 cycles)
35h
00h
Col. Add. 1, 2 and Row Add. 1, 2, 3
Source Address on Plane 0
Add. (5 cycles)
35h
Col. Add. 1, 2 and Row Add. 1, 2, 3
Source Address on Plane 1
1
tDBSY
tPROG
R/B#
I/Ox
85h
Add. (5 cycles)
81h
11h
Add. (5 cycles)
10h
70h
(Note 2)
1
Col. Add. 1, 2 and Row Add. 1, 2, 3
Destination Address
Col. Add. 1, 2 and Row Add. 1, 2, 3
Destination Address
A0 ~ A11 : Fixed ‘Low’
A12 ~ A17 : Fixed ‘Low’
A18
: Fixed ‘Low’
A19 ~ A28 : Fixed ‘Low’
A0 ~ A11 : Fixed ‘Low’
A12 ~ A17 : Valid
A18
: Fixed ‘High’
A19 ~ A28 : Valid
Plane 0
Plane 1
Source Page
Source Page
Target Page
(1)
Data Field
(1) : Copy Back Read on Plane 0
(2) : Copy Back Read on Plane 1
(3) : Multiplane Copy Back Program
Target Page
(2)
(3)
Spare Field
(3)
Data Field
Spare Field
Notes:
1. Copy Back Program operation is allowed only within the same memory plane.
2. Any command between 11h and 81h is prohibited except 70h, 78h, and FFh.
3. A18 is the plane address bit for ×8 devices. A17 is the plane address bit for ×16 devices.
Document Number: 002-00676 Rev. *T
Page 48 of 73
S34ML01G1
S34ML02G1, S34ML04G1
Figure 6.21 Multiplane Copy Back Program (ONFI 1.0 Protocol)
CLE
WE#
ALE
RE#
IOx
85h
C1 A
C2 A
R1A R2A R3A
85h
11h
C1B
C2B
R1B
R2B
R3B
10h
t IPBSY
SR[6]
t PROG
A
Notes:
1. C1A-C2A Column address for page A. C1A is the least significant byte.
2. R1A-R3A Row address for page A. R1A is the least significant byte.
3. C1B-C2B Column address for page B. C1B is the least significant byte.
4. R1B-R3B Row address for page B. R1B is the least significant byte.
5. The block address bits must be the same except for the bit(s) that select the plane.
6.19
Read Status Register Timing
Figure 6.22 Status / EDC Read Cycle
tCLR
CLE
tCLS
tCLH
tCS
CE#
tCH
tWP
WE#
tCEA
tWHR
tCHZ
tCOH
RE#
tRHZ
tDS
I/Ox
tDH
70h or 7Bh
tIR
tREA
tRHOH
Status Output
= Don’t Care
Document Number: 002-00676 Rev. *T
Page 49 of 73
S34ML01G1
S34ML02G1, S34ML04G1
6.20
Read Status Enhanced Timing
Figure 6.23 Read Status Enhanced Timing
CLE
tWHR
WE#
ALE
RE#
tAR
I/O0-7
6.21
78h
R1
R3
R2
SR
Reset Operation Timing
Figure 6.24 Reset Operation Timing
WE#
ALE
CLE
RE#
I/O7:0
FF
t RST
R/B#
Document Number: 002-00676 Rev. *T
Page 50 of 73
S34ML01G1
S34ML02G1, S34ML04G1
6.22
Read Cache
Figure 6.25 Read Cache Operation Timing
A
CE#
CLE
tWC
ALE
WE#
tWB
tWB
tWB
tRC
RE#
tRC
tRR
tRR
I/Ox
Col.
Add 1
00h
Col.
Add 2
Row
Add 1
Column Address 00h
Row
Add 2
Row
Add 3
30h
Dout
1
Dout
0
31h
Col. Add. 0
Page Address N
Dout
1
Page N + 1
Col. Add. 0
Page N
tCBSYR
tCBSYR
tR
R/B#
Dout
0
31h
Dout
5
1
2
3
A
4
CE#
CLE
ALE
WE#
tWB
tWB
tRC
tRC
RE#
tRR
I/Ox
Dout
tRR
Dout
0
31h
Dout
1
Dout
Page N + 2
tCBSYR
tCBSYR
6
5
8
7
9
Page N
Data Cache
2
1
Page Buffer
Dout
Page N + 3
Col. Add. 0
Col. Add. 0
R/B#
Dout
1
Dout
0
3Fh
Page N + 1
4
3
Page N + 2
6
5
3
5
Page N + 3
8
7
9
Page N + 3
Page N + 2
Page N + 1
Page N
1
= Don’t Care
7
Cell Array
Page N
Page N + 1
Page N + 2
Page N + 3
Figure 6.26 “Sequential” Read Cache Timing, Start (and Continuation) of Cache Operation
As defined for
Read
Cycle Type
CMD
CMD
Dout
Dout
Dout
CMD
I/Ox
30h
31h
D0
...
Dn
31h
tWB
SR[6]
Document Number: 002-00676 Rev. *T
tWB
tR
tRR
tCBSYR
Dout
D0
tWB
tRR
tCBSYR
Page 51 of 73
S34ML01G1
S34ML02G1, S34ML04G1
Figure 6.27 “Random” Read Cache Timing, Start (and Continuation) of Cache Operation
As defined
for Read
A
Cycle Type
CMD
CMD
ADDR
ADDR
I/Ox
30h
00h
C1
C2
ADDR
ADDR
ADDR
CMD
R3
31h
Dout
Dout
Dout
D0
...
Dn
Page N
R1
R2
tRR
tR
tWB
SR[6]
tRR
tWB
tCBSYR
A
Cycle Type
CMD
ADDR
ADDR
I/Ox
00h
C1
C2
ADDR
ADDR
ADDR
CMD
R3
31h
Dout
Page R
R1
R2
D0
tWB
SR[6]
tRR
tCBSYR
Figure 6.28 Read Cache Timing, End Of Cache Operation
As defined for
Read Cache
(Sequential or Random)
Cycle Type
CMD
I/Ox
31h
tRR
tWB
SR[6]
tCBSYR
Document Number: 002-00676 Rev. *T
Dout
Dout
Dout
CMD
D0
...
Dn
3Fh
tWB
Dout
Dout
Dout
D0
...
Dn
tRR
tCBSYR
Page 52 of 73
S34ML01G1
S34ML02G1, S34ML04G1
6.23
Cache Program
Figure 6.29 Cache Program
CLE
CE#
tWC
tWC
WE#
tWB
ALE
RE#
80h
I/Ox
Col.
Add1
Col.
Add2
Row.
Add1
Column Address
Row.
Add2
Row.
Add3
Din
N
Din
M
15h
80h
Row Address
Col.
Add1
Col.
Add2
Row.
Add1
Column Address
Row.
Add2
Row.
Add3
Din
N
Din
M
15h
Row Address
R/B#
tCBSYW
tCBSYW
1
CLE
CE#
tWC
WE#
ALE
RE#
tADL
I/Ox
80h
Col.
Add1
Col.
Add2
Column Address
Row.
Add1
Row.
Add2
Row.
Add3
Din
N
Din
M
10h
70h
Status
Row Address
R/B#
1
Document Number: 002-00676 Rev. *T
tPROG
Page 53 of 73
S34ML01G1
S34ML02G1, S34ML04G1
6.24
Multiplane Cache Program — S34ML02G1 and S34ML04G1
Figure 6.30 Multiplane Cache Program
Command Input
Address Input
80h
11h
Data Input
A13~A17: Fixed ‘Low’
A18: Fixed ‘Low’
A19~A31: Fixed ‘Low’
RY/BY#
Data Input
Address Input
81h
15h
A13~A17: Valid
A18: Fixed ‘High’
A19~A31: Valid
tDBSY
tCBSYW
1
Return to 1
Repeat a max of 63 times
Command Input
Address Input
80h
11h
Data Input
A13~A17: Fixed ‘Low’
A18: Fixed ‘Low’
A19~A31: Fixed ‘Low’
RY/BY#
Data Input
Address Input
81h
10h
A13~A17: Valid
A18: Fixed ‘High’
A19~A31: Valid
tDBSY
tPROG
1
CLE
CE#
tWC
tWB
WE#
ALE
tWB
RE#
tADL
I/Ox
80h
Col.
Add1
Col.
Add2
Row
Add1
Column Address
Row
Add2
Row
Add3
Din
N
tADL
Din
M
11h
81h
Row Address
Col.
Add1
Col.
Add2
Row
Add1
Column Address
Row
Add2
Row
Add3
Din
N
Din
M
15h
Row Address
R/B#
tDBSY
tCBSYW
1
CLE
CE#
tWC
tWB
WE#
ALE
RE#
I/Ox
80h
Col.
Add1
Col.
Add2
Row
Add1
Column Address
Row
Add2
Row
Add3
Din
N
Din
M
81h
11h
Row Address
Col.
Add1
Col.
Add2
Row
Add1
Column Address
Row
Add2
Row
Add3
Din
N
Din
M
10h
70h
Status
Row Address
R/B#
1
tDBSY
tPROG
Notes:
1. Read Status Register (70h) is used in the figure. Read Status Enhanced (78h) can be also used.
2. A18 is the plane address bit for ×8 devices. A17 is the plane address bit for ×16 devices.
Document Number: 002-00676 Rev. *T
Page 54 of 73
S34ML01G1
S34ML02G1, S34ML04G1
Figure 6.31 Multiplane Cache Program (ONFI 1.0 Protocol)
Command Input
Address Input
80h
11h
Data Input
Data Input
Address Input
80h
15h
tDBSY
RY/BY#
tCBSYW
1
Return to 1
Repeat a max of 63 times
Command Input
Address Input
80h
11h
Data Input
Data Input
Address Input
80h
10h
tPROG
tDBSY
RY/BY#
1
CLE
CE#
tWC
tWB
WE#
ALE
tWB
RE#
tADL
IOx
80h
Col.
Add1
Col.
Add2
Row
Add1
Column Address
Row
Add2
Row
Add3
tADL
Din
N
Din
M
11h
80h
Row Address
Col.
Add1
Col.
Add2
Row
Add1
Column Address
Row
Add2
Row
Add3
Din
N
Din
M
15h
Row Address
R/B#
tDBSY
tCBSYW
1
CLE
CE#
tWC
tWB
WE#
ALE
RE#
80h
IOx
Col.
Add1
Col.
Add2
Row
Add1
Column Address
Row
Add2
Row
Add3
Din
N
Din
M
80h
11h
Row Address
Col.
Add1
Col.
Add2
Row
Add1
Column Address
Row
Add2
Row
Add3
Din
N
Din
M
10h
70h
Status
Row Address
R/B#
1
tDBSY
tPROG
Notes:
1. The block address bits must be the same except for the bit(s) that select the plane.
2. Read Status register (70h) is used in the figure. Read Status Enhanced (78h) can be also used.
Document Number: 002-00676 Rev. *T
Page 55 of 73
S34ML01G1
S34ML02G1, S34ML04G1
6.25
Read ID Operation Timing
Figure 6.32 Read ID Operation Timing
CLE
CE#
WE#
tWHR
tAR
ALE
tREA
RE#
1 Gb Device
I/Ox
2 Gb Device
I/Ox
I/Ox
4 Gb Device
90h
00h
01h
F1h
00h
1Dh
90h
00h
01h
DAh
90h
95h
44h
90h
09h
00h
01h
DCh
90h
95h
54h
Maker
Code
Device
Code
4th Cycle
5th Cycle
ID2 Data
ID2 Data
4th Cycle
5th Cycle
Read ID
Command
6.26
Address 1
Cycle
3rd Cycle
Read ID2 Operation Timing
Figure 6.33 Read ID2 Operation Timing
CLE
CE#
WE#
tR
ALE
RE#
I/Ox
30h 65h 00h 00h 02h 02h 00h 30h
Read ID2
Commands
4 Cycle Address
Read ID2
Confirm
Command
ID2 Data
ID2 Data
ID2 Data
1st Cycle
2nd Cycle
3rd Cycle
R/B#
(Note 1)
Busy
Notes:
1. 4-cycle address is shown for the S34ML01G1. For S34ML02G1 and S34ML04G1, insert an additional address cycle of 00h.
2. If Status Register polling is used to determine completion of the Read ID2 operation, the Read Command (00h) must be issued before ID2 data can be read from the
flash.
Document Number: 002-00676 Rev. *T
Page 56 of 73
S34ML01G1
S34ML02G1, S34ML04G1
6.27
Read ONFI Signature Timing
Figure 6.34 ONFI Signature Timing
CLE
WE#
ALE
RE#
IO0~7
t WHR
90h
20h
4Fh
4Eh
46h
49h
tREA
6.28
Read Parameter Page Timing
Figure 6.35 Read Parameter Page Timing
CLE
WE#
ALE
RE#
IO0-7
ECh
R/B#
00h
P00
P10
...
P01
P11
...
tR
Note:
1. If Status Register polling is used to determine completion of the read operation, the Read Command (00h) must be issued before data can be read from the page
buffer.
Document Number: 002-00676 Rev. *T
Page 57 of 73
S34ML01G1
S34ML02G1, S34ML04G1
6.29
OTP Entry Timing
Figure 6.36 OTP Entry Timing
CLE
WE#
ALE
I/O0-7
6.30
29h 17h
04h
19h
Power On and Data Protection Timing
Figure 6.37 Power On and Data Protection Timing
Vcc(min)
Vcc(min)
VTH
VTH
VCC
0V
don’t
care
don’t
care
CE
WP
VIH
VIL
100 µs max
Invalid
5 ms max
Operation
VIL
don’t
care
Ready/Busy
Note:
1. VTH = 1.8 Volts.
Document Number: 002-00676 Rev. *T
Page 58 of 73
S34ML01G1
S34ML02G1, S34ML04G1
6.31
WP# Handling
Figure 6.38 Program Enabling / Disabling Through WP# Handling
WE#
WE#
tWW
I/Ox
tWW
80h
10h
I/Ox
WP#
WP#
R/B#
R/B#
80h
10h
Figure 6.39 Erase Enabling / Disabling Through WP# Handling
WE#
WE#
tWW
I/Ox
tWW
60h
D0h
I/Ox
WP#
WP#
R/B#
R/B#
Document Number: 002-00676 Rev. *T
60h
D0h
Page 59 of 73
S34ML01G1
S34ML02G1, S34ML04G1
7. Physical Interface
7.1
7.1.1
Physical Diagram
48-Pin Thin Small Outline Package (TSOP1)
Figure 7.1 TS/TSR 48 — 48-lead Plastic Thin Small Outline, 12 x 20 mm, Package Outline
PACKAGE
NOTES:
TS/TSR 48
JEDEC
MO-142 (D) DD
SYMBOL
MIN
NOM
MAX
A
---
---
1.20
A1
0.05
---
0.15
A2
0.95
1.00
1.05
b1
0.17
0.20
0.23
b
0.17
0.22
0.27
c1
0.10
---
0.16
c
0.10
---
0.21
D
19.80
20.00
20.20
D1
18.30
18.40
18.50
E
11.90
12.00
12.10
e
L
0.50 BASIC
0.50
0.60
0˚
---
8
R
0.08
---
0.20
48
Document Number: 002-00676 Rev. *T
DIMENSIONS ARE IN MILLIMETERS (mm).
(DIMENSIONING AND TOLERANCING CONFORM TO ANSI Y14.5M-1994).
2.
PIN 1 IDENTIFIER FOR STANDARD PIN OUT (DIE UP).
3.
PIN 1 IDENTIFIER FOR REVERSE PIN OUT (DIE DOWN): INK OR LASER MARK.
4.
TO BE DETERMINED AT THE SEATING PLANE -C- . THE SEATING PLANE IS
DEFINED AS THE PLANE OF CONTACT THAT IS MADE WHEN THE PACKAGE LEADS
ARE ALLOWED TO REST FREELY ON A FLAT HORIZONTAL SURFACE.
5.
DIMENSIONS D1 AND E DO NOT INCLUDE MOLD PROTRUSION. ALLOWABLE MOLD
PROTRUSION ON E IS 0.15mm PER SIDE AND ON D1 IS 0.25mm PER SIDE.
6.
DIMENSION b DOES NOT INCLUDE DAMBAR PROTRUSION. ALLOWABLE DAMBAR
PROTRUSION SHALL BE 0.08mm TOTAL IN EXCESS OF b DIMENSION AT MAX.
MATERIAL CONDITION. DAMBAR CANNOT BE LOCATED ON LOWER RADIUS OR THE
FOOT. MINIMUM SPACE BETWEEN PROTRUSION AND AN ADJACENT LEAD TO BE 0.07mm.
7.
THESE DIMENSIONS APPLY TO THE FLAT SECTION OF THE LEAD BETWEEN
0.10mm AND 0.25mm FROM THE LEAD TIP.
8.
LEAD COPLANARITY SHALL BE WITHIN 0.10mm AS MEASURED FROM
THE SEATING PLANE.
9.
DIMENSION "e" IS MEASURED AT THE CENTERLINE OF THE LEADS.
0.70
O
N
1.
5006 \ f16-038 \ 6.5.13
Page 60 of 73
S34ML01G1
S34ML02G1, S34ML04G1
7.1.2
63-Pin Ball Grid Array (BGA)
Figure 7.2 VBM063 — 63-Pin BGA, 11 mm x 9 mm Package
NOTES:
PACKAGE
VBM 063
JEDEC
1. DIMENSIONING AND TOLERANCING METHODS PER
ASME Y14.5M-1994.
M0-207(M)
2. ALL DIMENSIONS ARE IN MILLIMETERS.
11.00 mm x 9.00 mm NOM
PACKAGE
SYMBOL
MIN
NOM
MAX
A
---
---
1.00
A1
0.25
---
---
NOTE
PROFILE
4.
BALL HEIGHT
5. SYMBOL "MD" IS THE BALL MATRIX SIZE IN THE
"D" DIRECTION.
D
11.00 BSC.
E
9.00 BSC.
BODY SIZE
D1
8.80 BSC.
MATRIX FOOTPRINT
E1
7.20 BSC.
MATRIX FOOTPRINT
MD
12
MATRIX SIZE D DIRECTION
ME
10
MATRIX SIZE E DIRECTION
n
b
BODY SIZE
63
0.40
0.45
BALL COUNT
0.50
eE
0.80 BSC.
BALL PITCH
0.80 BSC.
BALL PITCH
SD
0.40 BSC.
SOLDER BALL PLACEMENT
SE
0.40 BSC.
SOLDER BALL PLACEMENT
DEPOPULATED SOLDER BALLS
e REPRESENTS THE SOLDER BALL GRID PITCH.
SYMBOL "ME" IS THE BALL MATRIX SIZE IN THE
"E" DIRECTION.
n IS THE TOTAL NUMBER OF POPULATED SOLDER
BALL POSITIONS FOR MATRIX SIZE MD X ME.
6
DIMENSION "b" IS MEASURED AT THE MAXIMUM BALL
DIAMETER IN A PLANE PARALLEL TO DATUM C.
7
“SD” AND “SE” ARE MEASURED WITH RESPECT TO DATUMS
A AND B AND DEFINE THE POSITION OF THE CENTER
SOLDER BALL IN THE OUTER ROW.
BALL DIAMETER
eD
A3-A8,B2-B8,C1,C2,C9,C10
D1,D2,D9,D10,E1,E2,E9,E10
F1,F2,F9,F10,G1,G2,G9,G10
H1,H2,H9,H10,J1,J2,J9,J10
K1,K2,K9,K10
L3-L8,M3-M8
3. BALL POSITION DESIGNATION PER JEP95, SECTION
3, SPP-020.
WHEN THERE IS AN ODD NUMBER OF SOLDER BALLS IN
THE OUTER ROW “SD” OR “SE” = 0.
WHEN THERE IS AN EVEN NUMBER OF SOLDER BALLS IN
THE OUTER ROW, “SD” = eD/2 AND “SE” = eE/2.
8. "+" INDICATES THE THEORETICAL CENTER OF
DEPOPULATED BALLS.
9
A1 CORNER TO BE IDENTIFIED BY CHAMFER, LASER OR INK
MARK, METALLIZED MARK INDENTATION OR OTHER MEANS.
g5011\ 16-038.25 \ 6.5.13
Document Number: 002-00676 Rev. *T
Page 61 of 73
S34ML01G1
S34ML02G1, S34ML04G1
8. System Interface
To simplify system interface, CE# may be unasserted during data loading or sequential data reading as shown in Figure 8.1. By
operating in this way, it is possible to connect NAND flash to a microprocessor.
Figure 8.1 Program Operation with CE# Don't Care
CLE
CE# don’t care
CE#
WE#
ALE
I/Ox
80h
St art Add. (5 Cycle)
Dat a I nput
Data Input
10h
Figure 8.2 Read Operation with CE# Don't Care
CLE
CE# don’t care
CE#
RE#
ALE
R/B#
tR
WE#
I/Ox
00h
Document Number: 002-00676 Rev. *T
St art Add. (5 Cycle)
30h
Dat a Out put ( sequent ial)
Page 62 of 73
S34ML01G1
S34ML02G1, S34ML04G1
Figure 8.3 Page Programming Within a Block
Page 63
(64)
Page 63
(64)
Page 31
(32)
Page 31
(1)
Page 2
(3)
Page 2
(3)
Page 1
Page 0
(2)
(1)
Page 1
Page 0
(32)
(1)
Data Register
Data Register
From the LSB page to MSB page
DATA IN : Data (1)
Document Number: 002-00676 Rev. *T
Data (64)
Ex.) Random page program (Optional)
DATA IN : Data (1)
Data (64)
Page 63 of 73
S34ML01G1
S34ML02G1, S34ML04G1
9. Error Management
9.1
System Bad Block Replacement
Over the lifetime of the device, additional Bad Blocks may develop. In this case, each bad block has to be replaced by copying any
valid data to a new block. These additional Bad Blocks can be identified whenever a program or erase operation reports “Fail” in the
Status Register.
The failure of a page program operation does not affect the data in other pages in the same block, thus the block can be replaced by
re-programming the current data and copying the rest of the replaced block to an available valid block. Refer to Table 9.1 and
Figure 9.1 for the recommended procedure to follow if an error occurs during an operation.
Table 9.1 Block Failure
Operation
Recommended Procedure
Erase
Block Replacement
Program
Block Replacement
Read
ECC (1 bit / 512+16 byte)
Figure 9.1 Bad Block Replacement
Block A
Block B
(2)
Data
th
N page
Data
th
Failure (1)
N page
(3)
FFh
FFh
buffer memory of the controller
Notes:
1. An error occurs on the Nth page of Block A during a program operation.
2. Data in Block A is copied to the same location in Block B, which is a valid block.
3. The Nth page of block A, which is in controller buffer memory, is copied into the Nth page of Block B.
4. Bad block table should be updated to prevent from erasing or programming Block A.
Document Number: 002-00676 Rev. *T
Page 64 of 73
S34ML01G1
S34ML02G1, S34ML04G1
9.2
Bad Block Management
Devices with Bad Blocks have the same quality level and the same AC and DC characteristics as devices where all the blocks are
valid. A Bad Block does not affect the performance of valid blocks because it is isolated from the bit line and common source line by
a select transistor. The devices are supplied with all the locations inside valid blocks erased (FFh). The Bad Block Information is
written prior to shipping. Any block where the 1st byte in the spare area of the 1st or 2nd or last page does not contain FFh is a Bad
Block. That is, if the first page has an FF value and should have been a non-FF value, then the non-FF value in the second page or
the last page will indicate a bad block.The Bad Block Information must be read before any erase is attempted, as the Bad Block
Information may be erased. For the system to be able to recognize the Bad Blocks based on the original information, it is
recommended to create a Bad Block table following the flowchart shown in Figure 9.2. The host is responsible to detect and track
bad blocks, both factory bad blocks and blocks that may go bad during operation. Once a block is found to be bad, data should not
be written to that block.The 1st block, which is placed on 00h block address is guaranteed to be a valid block.
Figure 9.2 Bad Block Management Flowchart
Start
Block Address=
Block 0
Increment
Block Address
(1)
No
Last
Block?
No
Data
=FFh?
Update
Bad Block Table
Yes
Yes
End
Note:
1. Check for FFh at the 1st byte in the spare area of the 1st, 2nd, and last pages.
Document Number: 002-00676 Rev. *T
Page 65 of 73
S34ML01G1
S34ML02G1, S34ML04G1
10. Ordering Information
The ordering part number is formed by a valid combination of the following:
S34ML
04G
1
00
T
F
I
00
0
Packing Type
0 = Tray
3 = 13” Tape and Reel
Model Number
00 = Standard Interface / ONFI (×8)
00 = Standard Interface (×16)
01 = ONFI (×16)
Temperature Range
I = Industrial (–40°C to + 85°C)
A = Industrial with AECQ-100 and GT Grade (-40˚C to +85˚C)
V = Industrial Plus (–40°C to + 105°C)
B = Industrial Plus with AECQ-100 and GT Grade (-40˚C to +105˚C)
Materials Set
F = Lead (Pb)-free
H = Lead (Pb)-free and Low Halogen
Package
B = BGA
T = TSOP
Bus Width
00 = ×8 NAND, single die
04 = ×16 NAND, single die
Technology
1 = Cypress NAND Revision 1 (4x nm)
Density
01G= 1 Gb
02G= 2 Gb
04G= 4 Gb
Device Family
S34ML - 3V
Cypress SLC NAND Flash Memory for Embedded
Valid Combinations
Valid Combinations list configurations planned to be supported in volume for this device. Consult your local sales office to confirm
availability of specific valid combinations and to check on newly released combinations.
Valid Combinations
Device
Family
Density
Technology
Bus
Width
Package
Type
1
00, 04
TF, BH
Temperature
Range
Additional
Ordering Options
Packing
Type
Package
Description
00, 01
0, 3
TSOP, BGA (1)
01G
S34ML
02G
I
A, V, B (2)
04G
Notes:
1. BGA package marking omits the leading “S34” and the Packing Type designator from the ordering part number.
2. A, V, B: 4G ×16 (04 in bus width) available, but for other ×16 versions contact factory.
Document Number: 002-00676 Rev. *T
Page 66 of 73
S34ML01G1
S34ML02G1, S34ML04G1
11. Document History Page
Document Title: S34ML01G1, S34ML02G1, S34ML04G1 1 Gb, 2 Gb, 4 Gb, 3 V SLC NAND Flash for Embedded
Document Number: 002-00676
Rev.
ECN No.
Orig. of
Change
Submission
Date
**
-
XILA
04/16/2012
Initial release
05/04/2012
Global: Removed Spansion Confidential designation
Read Status Enhanced: Updated text
Command Set: Updated table: Command Set
Read IDUpdated table: Read ID for Supported Configurations
Legacy Read ID: Removed section heading: Legacy Read ID
Valid BlocksUpdated table: Valid Blocks
05/23/2012
Global: Changed Cache Read to Read Cache
General Description: Updated text
Block Diagram: Combined three block diagrams into one
Addressing: Updated Address Cycle Map tables
Mode Selection: Updated table: Busy Time in Read; updated note
Command Set: Updated table
Added ‘Supported in S34ML01G1’ column
Copy Back Program: Updated text
Multiplane Copy Back Program: Updated text
Special Read for Copy Back: Updated text
Read EDC Status Register: Updated text
Read ID: Read ID Byte 4 Description — S34ML01G1 table: changed Number
of I/O to Spare Area Size (byte / 512 byte)
Absolute Maximum Ratings: Updated Input or Output Voltage and Supply Voltage rows
Program / Erase Characteristics: Updated table
05/24/2012
Performance: Updated Performance section
Read ID: Updated Read ID for Supported Configurations table
Modified tables: Read ID Byte 3 Description, Read ID Byte 4 Description –
S34ML01G1, Read ID Byte 4 Description – S34ML02G1 and S34ML04G1,
Read ID Byte 5 Description – S34ML02G1 and S34ML04G1
AC Test Conditions: Updated table
05/31/2012
Global: Data Sheet designation updated from Advance Information to Preliminary
Distinctive Characteristics/PerformanceUpdated Distinctive Characteristics and
Performance section
Pin Description: Updated Pin Description table
Addressing: Updated Address Cycle Map — 1 Gb Device table
Updated Address Cycle Map — 2 Gb Device table
Updated Address Cycle Map — 4 Gb Device table
Command Se: Updated Command Set table
*A
*B
*C
*D
-
-
-
-
XILA
XILA
XILA
XILA
Document Number: 002-00676 Rev. *T
Description of Change
Page 67 of 73
S34ML01G1
S34ML02G1, S34ML04G1
11. Document History Page (Continued)
Document Title: S34ML01G1, S34ML02G1, S34ML04G1 1 Gb, 2 Gb, 4 Gb, 3 V SLC NAND Flash for Embedded
Document Number: 002-00676
Rev.
*E
*F
*G
ECN No.
-
-
-
Orig. of
Change
Submission
Date
Description of Change
07/13/2012
Performance: Corrected Page Read/Program - Sequential access: from 25ns
(Max) to 25 ns (Min)
Connection DiagramCorrected figure: 48-Pin TSOP1 Contact x8 Device
Mode Selection: Mode selection table: corrected Busy Time in Read, WE# from
High to X; corrected Notes
Command Set: Command Set table: added ONFI, Extended Read Status, and
Read ID2 commands
Note that all ONFI information is in the Advanced Information designation
Copy Back Program: Updated section
Multiplane Copy Back Program — S34ML02G1 and S34ML04G1Updated section
Read ID2: Added section
Read ONFI Signature: Added Section
Note that all ONFI information is in the Advanced Information designation
Read Parameter Page: Added section
Note that all ONFI information is in the Advanced Information designation
One-Time Programmable (OTP) Entry: Added section
Note that all ONFI information is in the Advanced Information designation
Program/Erase Characteristics: Added note to table
Timing DiagramsRearranged section
Added timing diagrams: Multiplane Block Erase (ONFI 1.0 Protocol), Multiplane
Cache Program (ONFI 1.0 Protocol), Read ID2 Operation Timing, ONFI Signature Timing, Read Parameter Page Timing, Read ID2 Operation Timing, OTP
Entry Timing
Updated timing diagrams: Page Read Operation (Read One Page), Page Read
Operation Intercepted by CE#, Page Read Operation Timing with CE# Don’t
Care, Page Program Operation, Page Program Operation Timing with CE#
Don’t Care, Random Data Input, Random Data Output, Multiplane Page Program, Block Erase Operation (Erase One Block), Reset Operation Timing, Read
Cache Operation Timing, Cache Program, Multiplane Cache Program, Read ID
Operation Timing
Note that all ONFI information is in the Advanced Information designation
07/23/2012
Command Set: Command Set table: changed Read ONFI Signature to ‘Yes’ for
Supported on S34ML01G1
Read Parameter Page: Parameter Page Description table: changed Byte 254255 Values
Valid Blocks: Valid Blocks table: removed Note 1 and Note 3
DC Characteristics: DC Characteristics and Operating Conditions table:
corrected Output low voltage Test Conditions
corrected Output low current (R/B#) Typ and Max values
08/02/2012
Global: Note that all ONFI information is now in the Preliminary designation
Read Parameter Page: Parameter Page Description table: updated values for
bytes 6-7, 108-109, 254-255
Physical Interface: Added TSOP (2 CE 8 Gb) diagram
Added BGA diagram
Ordering Information: Updated data
Appendix A: Added Errata
XILA
XILA
XILA
Document Number: 002-00676 Rev. *T
Page 68 of 73
S34ML01G1
S34ML02G1, S34ML04G1
11. Document History Page (Continued)
Document Title: S34ML01G1, S34ML02G1, S34ML04G1 1 Gb, 2 Gb, 4 Gb, 3 V SLC NAND Flash for Embedded
Document Number: 002-00676
Rev.
*H
*I
*J
*K
ECN No.
-
-
-
-
Orig. of
Change
Submission
Date
Description of Change
08/29/2012
Global: Removed 8 Gb data
Added x16 I/O bus width data
Revision 10 (September 6, 2012)
Connection Diagram: 48-Pin TSOP1 Contact x8, x16 Devices figure: corrected
pinouts
63-VFBGA Contact, x16 Device (Balls Down, Top View) figure: corrected pinouts, removed note
Command Set: Reorganized section
AC Characteristics: Corrected TALS Min and TDS Min
XILA
XILA
XILA
XILA
Document Number: 002-00676 Rev. *T
09/06/2012
10/01/2012
11/02/2012
AddressingAddress Cycle Map -1 Gb Device: corrected data
Address Cycle Map -2 Gb Device: corrected data
Address Cycle Map -4 Gb Device: corrected data
Multiplane Program -S34ML02G1 and S34ML04G: Added text
Block EraseAdded text
Multiplane Block Erase -S34ML02G1 and S34ML04G1: Added text
Copy Back Program: Added text
Multiplane Copy Back Program — S34ML02G1 and S34ML04G: Added text
Multiplane Cache Program — S34ML02G1 and S34ML04G1: Added text
Read Parameter Page: Parameter Page Description table:
corrected Electrical Parameters Block values for bytes 129-130 and bytes 131132
corrected Vendor Block values for bytes 254-255
Multiplane Page Program Operation — S34ML02G1 and S34ML04G1Added
note to Multiplane Page Program figure
Added note to Multiplane Page Program (ONFI 1.0 Protocol) figure
Multiplane Block Erase — S34ML02G1 and S34ML04G1: Added note to Multiplane Block Erase figure
Updated note to Multiplane Block Erase (ONFI 1.0 Protocol) figure
Multiplane Copy Back Program — S34ML02G1 and S34ML04G1: Added note
to Multiplane Copy Back Program figure
Multiplane Copy Back Program (ONFI 1.0 Protocol) figure: corrected IOx values
Updated note
Multiplane Cache Program — S34ML02G1 and S34ML04G1Added note to Multiplane Cache Program figure
Multiplane Cache Program (ONFI 1.0 Protocol) figure:
removed address values from RY/BY#
changed IOx value from F1h to 70h
updated note
AC Characteristics: AC Characteristics table: added CE# access time
Connection Diagram: 48-Pin TSOP1 Contact x8, x16 Devices figure: corrected
pinouts
63-VFBGA Contact, x16 Device (Balls Down, Top View) figure: corrected pinouts, removed note
Global: Data Sheet designation updated from Preliminary to Full Production
Absolute Maximum Ratings: Added note
Ordering Information: Valid Combinations table: added to Additional Ordering
Options
Page 69 of 73
S34ML01G1
S34ML02G1, S34ML04G1
11. Document History Page (Continued)
Document Title: S34ML01G1, S34ML02G1, S34ML04G1 1 Gb, 2 Gb, 4 Gb, 3 V SLC NAND Flash for Embedded
Document Number: 002-00676
Rev.
*L
ECN No.
-
Orig. of
Change
Submission
Date
Description of Change
12/19/2012
Command Set: Added Page Reprogram command
Changed ReadID2 to be “Supported on S34ML01G1”
Page Reprogram: Moved section
Added paragraph
Copy Back ProgramAdded paragraph
Reset: Updated paragraph
ReadID2: Updated paragraph
Read Parameter Page: Parameter Page Description table:
fixed Values of Bytes 6-7 and 254-255
fixed Description of Bytes 129-130 and 131-132
DC CharacteristicsDC Characteristics and Operating Conditions table:
Power-On Reset Current (S34ML01G1): removed row
Operating Current: removed ICC1: tRC = tRC (min); ICC2: removed Cache
(S34ML01G1)
Input Leakage Current: removed VIN = 0 to VCC (max)
Output Leakage Current: removed VOUT = 0 to VCC (max)
Output High Voltage: removed IOH = -100 µA, IOH = 100 µA, and IOH = 400
µA rows
Output Low Voltage: removed IOL = -100 µA row
Output Low Current (R/B#): removed VOL = 0.1V row
AC Characteristics: AC Characteristics table: added note
Page Read Operation: Page Read Operation (Read One Page) figure: added
note
Read ID2 Operation Timin: Read ID2 Operation Timing figure:
replaced tWHR with tR and added R/B# timing signal
added note
Bad Block Management: Added text
Bad Block Management Flowchart: updated note
XILA
*M
-
XILA
02/28/2013
Command Set: Command Set table: removed ‘Nth Page’ entries
Page Program: Added paragraph
Multiplane Program — S34ML02G1 and S34ML04G1: Added paragraph
Page Reprogram — S34ML02G1 and S34ML04G1: Added paragraph
Block Eras: Added paragraph
Multiplane Block Erase — S34ML02G1 and S34ML04G1: Added paragraph
Copy Back Program: Added paragraph
Multiplane Copy Back Program — S34ML02G1 and S34ML04G1: Added paragraph
Cache Program — S34ML02G1 and S34ML04G: Added paragraph
Multiplane Cache Program — S34ML02G1 and S34ML04G1Added paragraph
Read Parameter Page: Added paragraph
Electrical Characteristics: Valid Blocks table: updated table
AC Characteristics: AC Characteristics table: corrected Min value for tCLS and
Max value for tCEA
Read Status Cycle Timing: status / EDC Read Cycle figure: removed Note
*N
-
XILA
03/07/2013
Ready/Busy: Updated section
Corrected Ready/Busy Pin Electrical Application figure
Document Number: 002-00676 Rev. *T
Page 70 of 73
S34ML01G1
S34ML02G1, S34ML04G1
11. Document History Page (Continued)
Document Title: S34ML01G1, S34ML02G1, S34ML04G1 1 Gb, 2 Gb, 4 Gb, 3 V SLC NAND Flash for Embedded
Document Number: 002-00676
Rev.
*O
ECN No.
-
Orig. of
Change
Submission
Date
Description of Change
08/09/2013
Distinctive Characteristics: Security -removed Serial number (unique ID)
Operating Temperature: removed Commercial and Extended temperatures
Performance: Updated Reliability
General Description: Updated section
Removed bullet: Serial number (unique identifier)
Addressing: Appended Note in all Address Cycle Map tables
Added text to Bus Cycle column in all Address Cycle Map tables
Mode Selection: Updated Mode Selection table
Command Set: Command Set table:
updated Acceptable Command during Busy column
Changed status of Cache Program (End) and Cache Program (Start) / (Continue) to ‘Supported on S34ML01G1’
Page Read: Updated section
Page Program: Changed sentence “In addition, pages must be sequentially
programmed within a block.” to “Pages may be programmed in any order within
a block.”
Multiplane Program — S34ML02G1 and S34ML04G1: Changed sentence “In
addition, pages must be programmed sequentially within a block.” to “Pages
may be programmed in any order within a block.”
Page Reprogram — S34ML02G1 and S34ML04G1: Corrected Page Reprogram figure
Corrected Page Reprogram with Data Manipulation figure
Copy Back Program: Updated section
Read Status Enhanced — S34ML02G1 and S34ML04G1: Updated section
Read Status Register Field Definition: Updated Status Register Coding table
Cache Program: Removed S34ML02G1 and S34ML04G1 from heading
Read ID: Read ID Bytes: updated Description
Read Parameter Page: Parameter Page Description table: corrected Values for
Bytes 8-9 and 254-255
Absolute Maximum Ratings: Updated Absolute Maximum Ratings table
Multiplane Page Program Operation — S34ML02G1 and S34ML04G1: Updated
Multiplane Page Program figure
Updated Multiplane Page Program (ONFI 1.0 Protocol)
Copy Back Read with Optional Data Readout: Corrected Copy Back Read with
Optional Data Readout figure
Copy Back Program Operation With Random Data Input: Updated Copy Back
Program Operation With Random Data Input figure
Read Status Register Timing: Removed Read Status Enhanced Cycle figure
Read Status Enhanced Timing: Removed Read Status Timing figure
Read Cache: Updated Read Cache Operation Timing figure
Removed Cache Timing heading
Cache Program:Updated Cache Program figure
Multiplane Cache Program — S34ML02G1 and S34ML04G1Updated Multiplane Cache Program figure
Updated Multiplane Cache Program (ONFI 1.0 Protocol) figure
Read Parameter Page Timing: Added Note to Read Parameter Page Timing
figure
One-Time Programmable (OTP) Entry: Added Note stating that the OTP feature
in the S34ML01G1 does not have non-volatile protection
XILA
Document Number: 002-00676 Rev. *T
Page 71 of 73
S34ML01G1
S34ML02G1, S34ML04G1
11. Document History Page (Continued)
Document Title: S34ML01G1, S34ML02G1, S34ML04G1 1 Gb, 2 Gb, 4 Gb, 3 V SLC NAND Flash for Embedded
Document Number: 002-00676
Rev.
*O (Cont’d)
ECN No.
-
Orig. of
Change
Submission
Date
Description of Change
08/09/2013
Operating Temperature (Commercial Temperature Range) and Ambient Operating Temperature (Extended Temperature Range)
Physical Interface: Updated figures:
TS/TSR 48 — 48-lead Plastic Thin Small Outline, 12 x 20 mm, Package Outline
VBM063 — 63-Pin BGA, 11 mm x 9 mm Package
System Interface: Updated Read Operation with CE# Don't Care figure
Ordering Information: Updated Materials Set: H = Low Halogen to H = Lead
(Pb)-free and Low Halogen
Added Note to Valid Combinations table
XILA
*P
-
XILA
02/10/2014
Distinctive Characteristic: Operating Temperature: Added Automotive
Read ID: Updated section
Ordering Information: Temperature Range: Added A, V, B
Valid Combinations: Temperature Range: Added A, V, B
*Q
4963050
XILA
11/02/2015
Updated to Cypress template
*R
5160512
XILA
04/25/2016
Added Recommended Operating Conditions section.
Updated DC Characteristics section - updated “VCC supply Voltage (erase and
program lockout)” to "Erase and Program Lockout voltage”.
Updated “Read Parameter Page” section.
Updated “Ordering Information”.
Updated copyright information at the end of the document.
*S
5409174
XILA
08/30/2016
Updated Reliability features in Performance.
*T
5738855
GNKK
05/16/2017
Updated the Cypress logo and copyright information.
Document Number: 002-00676 Rev. *T
Page 72 of 73
S34ML01G1
S34ML02G1, S34ML04G1
Sales, Solutions, and Legal Information
Worldwide Sales and Design Support
Cypress maintains a worldwide network of offices, solution centers, manufacturer’s representatives, and distributors. To find the office
closest to you, visit us at Cypress Locations.
PSoC® Solutions
Products
ARM® Cortex® Microcontrollers
Automotive
cypress.com/arm
cypress.com/automotive
Clocks & Buffers
cypress.com/clocks
Interface
cypress.com/interface
Internet of Things
cypress.com/iot
Memory
cypress.com/memory
Microcontrollers
cypress.com/mcu
PSoC
cypress.com/psoc
Power Management ICs
cypress.com/pmic
Touch Sensing
PSoC 1 | PSoC 3 | PSoC 4 | PSoC 5LP | PSoC 6
Cypress Developer Community
Forums | WICED IOT Forums | Projects | Video | Blogs |
Training | Components
Technical Support
cypress.com/support
cypress.com/touch
USB Controllers
cypress.com/usb
Wireless Connectivity
cypress.com/wireless
© Cypress Semiconductor Corporation 2012-2017. This document is the property of Cypress Semiconductor Corporation and its subsidiaries, including Spansion LLC ("Cypress"). This document,
including any software or firmware included or referenced in this document ("Software"), is owned by Cypress under the intellectual property laws and treaties of the United States and other countries
worldwide. Cypress reserves all rights under such laws and treaties and does not, except as specifically stated in this paragraph, grant any license under its patents, copyrights, trademarks, or other
intellectual property rights. If the Software is not accompanied by a license agreement and you do not otherwise have a written agreement with Cypress governing the use of the Software, then Cypress
hereby grants you under its copyright rights in the Software, a personal, non-exclusive, nontransferable license (without the right to sublicense) (a) for Software provided in source code form, to modify
and reproduce the Software solely for use with Cypress hardware products, only internally within your organization, and (b) to distribute the Software in binary code form externally to end users (either
directly or indirectly through resellers and distributors), solely for use on Cypress hardware product units. Cypress also grants you a personal, non-exclusive, nontransferable, license (without the right
to sublicense) under those claims of Cypress's patents that are infringed by the Software (as provided by Cypress, unmodified) to make, use, distribute, and import the Software solely to the minimum
extent that is necessary for you to exercise your rights under the copyright license granted in the previous sentence. Any other use, reproduction, modification, translation, or compilation of the Software
is prohibited.
CYPRESS MAKES NO WARRANTY OF ANY KIND, EXPRESS OR IMPLIED, WITH REGARD TO THIS DOCUMENT OR ANY SOFTWARE, INCLUDING, BUT NOT LIMITED TO, THE IMPLIED
WARRANTIES OF MERCHANTABILITY AND FITNESS FOR A PARTICULAR PURPOSE. Cypress reserves the right to make changes to this document without further notice. Cypress does not
assume any liability arising out of the application or use of any product or circuit described in this document. Any information provided in this document, including any sample design information or
programming code, is provided only for reference purposes. It is the responsibility of the user of this document to properly design, program, and test the functionality and safety of any application
made of this information and any resulting product. Cypress products are not designed, intended, or authorized for use as critical components in systems designed or intended for the operation of
weapons, weapons systems, nuclear installations, life-support devices or systems, other medical devices or systems (including resuscitation equipment and surgical implants), pollution control or
hazardous substances management, or other uses where the failure of the device or system could cause personal injury, death, or property damage ("Unintended Uses"). A critical component is any
component of a device or system whose failure to perform can be reasonably expected to cause the failure of the device or system, or to affect its safety or effectiveness. Cypress is not liable, in whole
or in part, and Company shall and hereby does release Cypress from any claim, damage, or other liability arising from or related to all Unintended Uses of Cypress products. Company shall indemnify
and hold Cypress harmless from and against all claims, costs, damages, and other liabilities, including claims for personal injury or death, arising from or related to any Unintended Uses of Cypress
products.
Cypress, the Cypress logo, Spansion, the Spansion logo, and combinations thereof, WICED, PSoC, CapSense, EZ-USB, F-RAM, and Traveo are trademarks or registered trademarks of Cypress in
the United States and other countries. For a more complete list of Cypress trademarks, visit cypress.com. Other names and brands may be claimed as property of their respective owners.
Document Number: 002-00676 Rev. *T
®
®
®
®
Revised Tuesday, May 16, 2017
Page 73 of 73
Cypress , Spansion , MirrorBit , MirrorBit Eclipse™, ORNAND™, HyperBus™, HyperFlash™, and combinations thereof, are trademarks and registered trademarks of Cypress Semiconductor Corp.