0
登录后你可以
  • 下载海量资料
  • 学习在线课程
  • 观看技术视频
  • 写文章/发帖/加入社区
创作中心
发布
  • 发文章

  • 发资料

  • 发帖

  • 提问

  • 发视频

创作活动
ES51992

ES51992

  • 厂商:

    CYRUSTEK

  • 封装:

  • 描述:

    ES51992 - 11,000 Counts ADC - Cyrustek corporation

  • 数据手册
  • 价格&库存
ES51992 数据手册
ES51992 11,000 Counts ADC Features • Max. 11,000 counts resolution • Conversion rate selectable by MPU command: 1.6/s 128/s • Input signal full scale: 110mV • 50/60Hz line noise rejection selectable by MPU command • Low battery detection • Multiple input channels for ADC • 3-wire serial bus and EOC signal for MPU I/O port • -3V power operation with internal charge pumping circuit • MPU I/O power level selectable by external control pin • Zero calibration for eliminating offset error • On-chip buzzer driving and frequency selectable by MPU command • Support sleep mode by external CS(chipselect) pin Description ES51992 is an 11000-count dual-slope analogto-digital converter (ADC). The conversion rate and buzzer frequency can be selected or decided by an external microprocessor. The conversion rate can be varied from 1.6 time/sec to 128 times/sec under 4MHz/12MHz crystal oscillation clock. Besides, ES51992 also provides multi-channels input, low battery detection, power-down mode, 50/60Hz line noise rejection selection, and I/O port level selection for flexible design. Application Clamp meter Thermometer Portable instrumentation 1 06/09/20 ES51992 11,000 Counts ADC Pin Assignment LQFP-32L CAZ CINT CREF+ CREFREF+ REFBUF RAZ 1 32 31 30 29 28 27 26 25 24 2 23 3 4 5 6 7 8 22 IO_control CS V12 AGND V- V+ DGND LBAT C+ COSC1 OSC2 uP_VCC BUZOUT EOC SCLK ES51992 21 20 19 18 9 10 11 12 13 14 15 16 17 VINSDATA VIN1+ VIN2+ NC NC NC VIN0 2 06/09/20 ES51992 11,000 Counts ADC Pin Description Pin No 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 Symbol CAZ CINT CREF+ CREFREF+ REFBUF RAZ NC NC NC VIN+ VIN1+ VIN2+ VINSDATA SCLK EOC BUZout uP_VCC OSC2 OSC1 CC+ CS I/O_control LBAT Type I O I/O I/O I I O O Description 28 29 30 31 32 DGND V+ VAGND V12 Auto-zero capacitor connection. Integrator output. Connect to integral capacitor Positive connection for reference capacitor. Negative connection for reference capacitor. Differential reference high voltage input. Differential reference low voltage input. Buffer output pin. Connect to integral resistor Buffer output pin in high-speed mode. Connect to high-speed integral resistor. Not connected Not connected Not connected I Analog differential high signal input. I Analog signal high input1 I Analog signal high input2 I Analog differential low signal input. I/O Serial data I/O pin. Nch open-drain output. I Serial clock input pin. O An indicator for ADC conversion ending. O Buzzer frequency output I MPU I/O port power level selection O Crystal oscillation connection I Crystal oscillation connection O Negative capacitor connection for on-chip DC-DC converter. O Positive capacitor connection for on-chip DC-DC converter. I Chip select input pin. Pull to Low to enter power down mode. I MPU I/O port ground level selection I Low battery configuration. If 3V battery is used, connect it to AGND. The default low-battery threshold voltage is –2.3V. If 9V or other battery voltage is used, the low battery annunciator is displayed when the voltage of this pin is less than V12 G Digital ground O/P Output of on-chip DC-DC converter. P Negative supply voltage. Connecting to 3V battery negative terminal. G Analog ground O Output of band-gap voltage reference. Typically –1.23V 3 06/09/20 ES51992 11,000 Counts ADC Function description 1. Dual Slope A/D-Four Phases Timing ES51992 is a dual-slope analog-to-digital converter (ADC). Figure 1 is a structure of dual-slope integrator. Its measurement cycle has two distinct phases: input signal integration (INT) phase and reference voltage integration (DINT) phase. In INT phase, the input signal is integrated for a fixed time period, then A/D enters DINT phase in which an opposite polarity constant reference voltage is integrated until the integrator output voltage becomes to zero. Since both the time period for input signal integration and the amount of reference voltage are fixed, thus the de-integration time is proportional to the input signal. Hence, we can define the mathematical equation about input signal, reference voltage integration (see Figure 1.): TINT 1 1 ∫0 V IN (t )dt = Buf × C int × VREF × TDINT Buf × C int where, V IN (t ) = input signal V REF = reference voltage T INT = integration time (fixed) TDINT = de-integration time (proportional to V IN (t ) ) input signal reference voltage Cint Buf RAZ BufX10 RAZ input signal > 0 integrator output integrator output input signal < 0 different input fixed slope integration time fixed slope different input integrator output Fixed Variable integration deintegration time time Fixed Variable integration deintegration time time integration time Figure 1. the structure of dual-slope integrator and its output waveform. If V IN (t ) is a constant, we can rewrite above equation: TDINT = T INT × V IN V REF 4 06/09/20 ES51992 11,000 Counts ADC Besides the INT phase and DINT phase, ES51992 exploits auto zero (AZ) phase and zero integration (ZI) phase to achieve accurate measurement. In AZ phase, the system offset is stored. The offset error will be eliminated in DINT phase. Thus a higher accuracy could be obtained. In ZI phase, the internal status will be recovered quickly to that of zero input. Thus the succeeding measurements won’t be disturbed by current measurement especially in case of overload. As mentioned above, the measurement cycle of ES51992 contains four phases: (1) auto zero phase (AZ) (2) input signal integration phase (INT) (3) reference voltage integration phase (DINT) (4) zero integration phase (ZI) The time ratios of these four phases, AZ, INT, DINT and ZI to the entire measurement cycle are 8.8%, 32%, 35.2% and 24% respectively. However the actual duration of each phase depends on conversion rate. An example is shown in the table below. A user can easily deduce other cases based on the table. Voltage: CR (times/sec) ZI (ms) AZ (ms) INT (ms) DINT (ms) 8 Voltge+PEAK: CR (times/sec) 30 11 40 44 Note: reference voltage = -100 mV. ZI (ms) AZ (ms) INT (ms) DINT (ms) 8 30 11 40 60 Note: reference voltage = -100 mV. 5 06/09/20 ES51992 11,000 Counts ADC 2. Component Value Selection for ADC For various application requirements on conversion rate and input full range, we suggest nominal values for external components of ADC in Figure 1 to obtain better performance. Under default condition with operating clock = 12 MHz: (1) conversion rate = 8 times/sec (2) reference voltage = -100 mV (3) input signal full scale = 110 mV (sensitivity = 10 uV) We suggest that Cint = 68 nF, Buf = 56 kΩ If a user selects a different conversion rate rather than default, the integration capacitor Cint value must be changed according to the following rule for better performance: Cint × (conversion rate) = (68 nF) × (8 times/sec). A smaller Cint reduces the input full range. However a larger Cint might have weaker noise immunity than the suggested one. A user could enlarge the input full range by changing reference voltage (Vref) and the amount of integration resistor (Buf). For example, if Vref & Buf are enlarged as twice than the default values then the input full range becomes 220 mV. The input full range can be enlarged up to 1.1V (10 times than the default case). We list general rules in below which might be helpful in determining component values. Buf / (reference voltage) = 56 kΩ / (-100 mV) 6 06/09/20 ES51992 11,000 Counts ADC 3. Multi Channel Input ES51992 provides VIN+, VIN1+, VIN2+ and Vin- pins to achieve the multi channel input (multiplexer) feature. Because ES51992 is a single core A-to-D converter, it can only process one pack of data per conversion period. Although it has four input pins, it would take only one pair as input channel from the four pins. The actual input channel is determined by the bits CH1/CH0 of STATUS Byte1 as the following table: Input Channel CH1 CH0 ch1 0 0 ch2 0 1 ch3 1 0 ch4 1 1 High Input VIN+ VIN1+ VIN2+ VIN2+ Low Input VINVINVINVIN1+ ES51992 also configures an input channel rotation (polling) feature. The rotation feature can be activated by setting the ROT bit of STATUS Byte2 to high. In the rotation mode, the actual input channel will be changed by ES51992 sequentially and automatically. The rotation feature has two types, one is for three input channel rotation with the same low input, another one is for two independent differential channel rotation. The following table presents the configuration of the rotation type. Rotation Type Table: ROT CH1,CH0 0,0 0,1 H 1,0 1,1 L - Rotation Type ch1 → ch2 → ch3 → ch1 … ch1 → ch4 → ch1 … Not Rotating 7 06/09/20 ES51992 11,000 Counts ADC 4. Special function 4.1 Zero and RZero Calibration The Zero and RZero calibration are designed for removing the error rise from the propagation delay of internal component. In Zero or RZero calibration mode, ES51992 outputs a calibration value. The normal measurement value must minus the calibration value to cancel the error and obtain a more accurate value. The following block diagram performs the difference between basic structures of normal mode, Zero calibration and RZero Calibration. We suggest users to do zero-calibration in most applications. IN + V IN + (a ) N o rm a l m o d e V IN - D u a l S lo p e ADC IN - IN + V IN + (b ) Z ero m o d e V IN - D u a l S lo p e ADC IN - IN + V IN + (c ) R Z ero m o d e V IN - D u a l S lo p e ADC IN - 8 06/09/20 ES51992 11,000 Counts ADC 4.2 Buzzer Setup When the bit BUZ of ID Byte is set to “H”, the BUZOUT will output a square signal of MPU I/O swing level to drive a external buzzer. The buzzer frequency is determined by the bits B0/B1/B2 of STATUS Byte3. The configuration of buzzer frequency is listed at the following table. B2/B1/B0 111 110 101 100 011 010 001 000 BUZout (kHz) 4.00 3.33 3.08 2.67 2.22 2.00 1.33 1.00 4.3 Low Battery Detection In a case of 3V battery power, the pin LBAT must be shorted to AGND. And the system will have low battery detection level about 2.3V. In another case of 9V or other battery power, the low battery detection happens when the voltage of LBAT is less than –1.23V below GND. And the bit LBAT of STATUS Byte3 will be set to high. A recommended application is shown as following: Low battery test (9V) 9V BA TT 230K 0V 680K LBAT 0.1u AGND V- The low battery detection level is around 7V 4.4 Sleep Mode When the pin CS is connected to V- or GND (depended on I/O_control level), the ES51992 will enter sleep mode. In Sleep mode, the chip draws a little supply current. It could extend the battery life. To leave sleep mode or stay in normal mode, the pin CS must be connected to AGND or floating. 9 06/09/20 ES51992 11,000 Counts ADC 5. MPU I/O function definition Write command: ID byte, Status byte1, Status byte2, Status byte3 START BIT B U Z0 A C K A C K A C K A C K STOP BIT 1 1 000 1 WRITE Read command: ID byte, Status byte1, Status byte2, Status byte3, Data byte1, Data byte2 START BIT 1 1 000 B U 1Z1 A C K A C K A C K A C K READ A C K N A K STOP BIT ID byte: 1 1 0 Status byte1: CH0 CH1 C0 Status byte2: S60 RZERO ZERO Status byte3: 0 0 B0 Data byte1: D0 D1 D2 Data byte2: D8 D9 D10 0 C1 ROT B1 D3 D11 0 C2 X B2 D4 D12 10 1 SIGN X LBAT D5 D13 BUZ SEL4M X X D6 X R/W X X X D7 X 06/09/20 ES51992 11,000 Counts ADC R/W: set to “H” is in read mode, set to “L” is in write mode CH1/CH0: ADC input channel selection, the default is [00]. Code VIN(+) VIN(-) 00 VIN0 channel VIN- channel 01 VIN1 channel VIN- channel 10 VIN2 channel VIN- channel 11 VIN2 channel VIN1 channel C2/C1/C0/S60: Conversion rate selection, the default is [0000] S60 C2/C1/C0 L H 101 128/s 128/s 100 96/s 96/s 011 64/s 76.8/s 010 32/s 38.4/s 001 16/s! 19.2/s* 000 8/s! 9.6/s* !* 110 3.2/s 3.84/s* 111 1.6/s!* 1.92/s* Crystal: 12MHz !: 50Hz line noise rejection, *: 60Hz line noise rejection SEL4M: “H” is XTAL is 4MHz version, “L” is default 12MHz XTAL S60 C2/C1/C0 X 101 128/s 100 64/s 011 64/s 010 32/s 001 16/s! 000 8/s! 110 3.2/s!* 111 1.6/s!* Crystal :4MHz SIGN: “H” is negative, “L” is positive LBAT: “H” is low battery detection flag active, the default is “L” RZERO: “H” is RZero calibration mode “ON”, the default is “L” ZERO: “H” is Zero calibration mode “ON”, the default is “L” ROT: Set to ”H” to enable multi channel rotating feature B2/B1/B0: Buzzer frequency selection (independent with conversion rate) BUZ: “H” is buzzer turn on and “L” is turn off, the default is turn off. 11 06/09/20 ES51992 11,000 Counts ADC Buzzer ON START BIT A C K STOP BIT 1 1 000 1 1 Buzzer OFF START BIT A C K STOP BIT 1 1 000 1 0 D13-D0: ADC output data according channel multiplex [CH1/CH0]. Binary code format. 6. Power and I/O output level selection Power Charge pump output for positive supply voltage(V+) External DC source to V+ is available by floating the charge pump capacitor I/O output level selectable uP_VCC provided by external DC source (the same high level with MPU) A control pin (I/O_control) selects the low level to –3V(V-) or 0V(DGND) I/O level uP_VCC I/O_control Example H L 3 H +3V 0V Ex.1 3 L +3V -3V Ex.2 0 L 0V -3V Ex.3 12 06/09/20 ES51992 11,000 Counts ADC ES5199X CC+ I/O_control SCLK SDATA EOC BUZOUT CS GND VV+ uP_VCC +3V +3V 0V -3V Ex.1 ES5199X CC+ V+ uP_VCC +3V I/O_control SCLK SDATA EOC BUZOUT CS GND V- +3V -3V -3V Ex.2 ES5199X CC+ I/O_control SCLK SDATA EOC BUZOUT CS GND VV+ uP_VCC 0V -3V -3V Ex.3 13 06/09/20 ES51992 11,000 Counts ADC Absolute Maximum Ratings Characteristic Supply Voltage (V- to AGND) Analog Input Voltage V+ AGND/DGND Digital Input Power Dissipation. Flat Package Operating Temperature Storage Temperature Rating -3.6V V- -0.6 to V+ +0.6 V+ ≥ (AGND/DGND+0.5V) AGND/DGND ≥ (V- -0.5V) V- -0.6 to DGND +0.6 or V+ +0.6 500mW 0℃ to 70℃ -25℃ to 125℃ DC Electrical Characteristics TA=25℃, VCM=0V, V- = -3V Parameter Power supply Operating supply current Conversion rate = 8/sec Voltage roll-over error Voltage nonlinearity Input Leakage Low battery flag voltage Internal pull-high to uP_Vcc current Internal pull-low to V- current Zero input reading Reference voltage and open circuit voltage for 110Ω measurement Reference voltage temperature coefficient VREF TCRF Symbol Test Condition VIDD Normal operation (XTAL=12MHz) ISS In sleep mode REV NLV Best case straight line V- to AGND CS (uP_Vcc=3V) CS(uP_Vcc=0V) I/O_control (V-=-3V) 10MΩ input resistor zero cal. by MPU 100KΩ resistor between VRH and AGND 100KΩ resister Between VRH 0℃
ES51992 价格&库存

很抱歉,暂时无法提供与“ES51992”相匹配的价格&库存,您可以联系我们找货

免费人工找货