0
登录后你可以
  • 下载海量资料
  • 学习在线课程
  • 观看技术视频
  • 写文章/发帖/加入社区
创作中心
发布
  • 发文章

  • 发资料

  • 发帖

  • 提问

  • 发视频

创作活动
DS26504LN+T&R

DS26504LN+T&R

  • 厂商:

    AD(亚德诺)

  • 封装:

    LQFP64

  • 描述:

    IC TELECOM INTERFACE 64LQFP

  • 数据手册
  • 价格&库存
DS26504LN+T&R 数据手册
DESIGN KIT AVAILABLE DS26504 T1/E1/J1/64KCC BITS Element www.maxim-ic.com GENERAL DESCRIPTION The DS26504 is a building-integrated timing-supply (BITS) clock-recovery element. It also functions as a basic T1/E1 transceiver. The receiver portion can recover a clock from T1, E1, 64kHz composite clock (64KCC), and 6312kHz synchronization timing interfaces. In T1 and E1 modes, the Synchronization Status Message (SSM) can also be recovered. The transmit portion can directly interface to T1, E1, or 64KCC synchronization interfaces as well as source the SSM in T1 and E1 modes. The DS26504 can translate between any of the supported inbound synchronization clock rates to any supported outbound rate. The DS26504 can also accept an 8kHz as well as a 19.44MHz reference clock. A separate output is provided to source a 6312kHz clock. The device is controlled through a parallel, serial, or hardware controller port. APPLICATIONS BITS Timing Rate Conversion FEATURES Accepts 8kHz and 19.44MHz References in Addition to T1, E1, and 64kHz Composite Clock GR378 Composite Clock Compliant G.703 2048kHz Synchronization Interface Compliant G.703 64kHz Option A & B Centralized Clock Synchronization Interface Compliant G.703 64kHz Japanese Composite Clock Synchronization Interface Compliant G.703 6312kHz Japanese Synchronization Interface Compliant Interfaces to Standard T1/J1 (1.544MHz) and E1 (2.048MHz) Interface to CMI-Coded T1/J1 and E1 T1/E1 Transmit Payload Clock Output Short- and Long-Haul Line Interface Transmit and Receive T1 BOC SSM Messages with Receive Message Change of State and Validation Indication Transmit and Receive E1 Sa(n) Bit SSM Messages with Receive Message Change of State Indication Crystal-Less Jitter Attenuator with Bypass Mode for T1 and E1 Operation Fully Independent Transmit and Receive Functionality Internal Software-Selectable Receive and Transmit Side Termination for 75Ω/100Ω/110Ω/120Ω/133Ω Monitor Mode for Bridging Applications Accepts 16.384MHz, 12.8MHz, 8.192MHz, 4.096MHz, 2.048MHz, or 1.544MHz Master Clock 64kHz, 8kHz, and 400Hz Outputs in Composite Clock Mode 8-Bit Parallel Control Port, Multiplexed or Nonmultiplexed, Intel or Motorola Serial (SPI) Control Port and Hardware Control Mode Provides LOS, AIS, and LOF Indications through Hardware Output Pins Fast Transmitter Output Disable through Device Pin for Protection Switching IEEE 1149.1 JTAG Boundary Scan 3.3V Supply with 5V Tolerant Inputs and Outputs Pin and Software Compatible with the DS26502 and DS26503 ORDERING INFORMATION PART DS26504L DS26504LN TEMP RANGE PIN-PACKAGE 0°C to +70°C 64 LQFP -40°C to +85°C 64 LQFP Note: Some revisions of this device may incorporate deviations from published specifications known as errata. Multiple revisions of any device may be simultaneously available through various sales channels. For information about device errata, click here: www.maxim-ic.com/errata. 1 of 129 REV: 072308 DS26504 T1/E1/J1/64KCC BITS Element TABLE OF CONTENTS 1. FEATURES .......................................................................................................................7 1.1 1.2 1.3 1.4 1.5 1.6 GENERAL .....................................................................................................................................7 LINE INTERFACE ...........................................................................................................................7 JITTER ATTENUATOR (T1/E1 MODES ONLY) ..................................................................................7 FRAMER/FORMATTER ...................................................................................................................8 TEST AND DIAGNOSTICS ...............................................................................................................8 CONTROL PORT ............................................................................................................................8 2. SPECIFICATIONS COMPLIANCE ...................................................................................9 3. BLOCK DIAGRAMS .......................................................................................................11 4. PIN FUNCTION DESCRIPTION .....................................................................................14 4.1 4.2 4.3 4.4 4.5 4.6 4.7 TRANSMIT PLL ...........................................................................................................................14 TRANSMIT SIDE ..........................................................................................................................14 RECEIVE SIDE ............................................................................................................................15 CONTROLLER INTERFACE ............................................................................................................16 JTAG.........................................................................................................................................20 LINE INTERFACE .........................................................................................................................21 POWER ......................................................................................................................................21 5. PINOUT...........................................................................................................................22 6. HARDWARE CONTROLLER INTERFACE....................................................................25 6.1 6.2 6.3 6.4 6.5 6.6 6.7 6.8 7. TRANSMIT CLOCK SOURCE .........................................................................................................25 INTERNAL TERMINATION ..............................................................................................................25 LINE BUILD-OUT .........................................................................................................................26 RECEIVER OPERATING MODES ....................................................................................................27 TRANSMITTER OPERATING MODES ..............................................................................................27 MCLK PRE-SCALER ...................................................................................................................28 PAYLOAD CLOCK OUTPUT ...........................................................................................................28 OTHER HARDWARE CONTROLLER MODE FEATURES ....................................................................29 PROCESSOR INTERFACE ............................................................................................30 7.1 7.2 7.2.1 7.2.2 7.2.3 7.2.4 7.2.5 7.2.6 7.3 7.3.1 7.3.2 7.3.3 7.4 7.5 7.6 7.7 PARALLEL PORT FUNCTIONAL DESCRIPTION ................................................................................30 SPI SERIAL PORT INTERFACE FUNCTIONAL DESCRIPTION ............................................................30 Clock Phase and Polarity ..................................................................................................................... 30 Bit Order............................................................................................................................................... 30 Control Byte ......................................................................................................................................... 30 Burst Mode........................................................................................................................................... 30 Register Writes..................................................................................................................................... 31 Register Reads .................................................................................................................................... 31 REGISTER MAP ...........................................................................................................................32 Power-Up Sequence ............................................................................................................................ 34 Test Reset Register ............................................................................................................................. 34 Mode Configuration Register ............................................................................................................... 35 INTERRUPT HANDLING ................................................................................................................37 STATUS REGISTERS....................................................................................................................37 INFORMATION REGISTERS ...........................................................................................................38 INTERRUPT INFORMATION REGISTERS .........................................................................................39 2 of 129 DS26504 T1/E1/J1/64KCC BITS Element 8. T1 FRAMER/FORMATTER CONTROL REGISTERS ....................................................40 8.1 9. T1 CONTROL REGISTERS............................................................................................................40 E1 FRAMER/FORMATTER CONTROL REGISTERS....................................................46 9.1 9.2 E1 CONTROL REGISTERS ...........................................................................................................46 E1 INFORMATION REGISTERS......................................................................................................49 10. I/O PIN CONFIGURATION OPTIONS ............................................................................53 11. T1 SYNCHRONIZATION STATUS MESSAGE ..............................................................56 11.1 11.2 11.3 12. T1 BIT-ORIENTED CODE (BOC) CONTROLLER ............................................................................56 TRANSMIT BOC ..........................................................................................................................56 RECEIVE BOC ............................................................................................................................57 E1 SYNCHRONIZATION STATUS MESSAGE ..............................................................65 12.1 SA/SI BIT ACCESS BASED ON CRC4 MULTIFRAME ......................................................................65 12.1.1 12.2 13. Sa Bit Change of State......................................................................................................................... 66 ALTERNATE SA/SI BIT ACCESS BASED ON DOUBLE-FRAME ..........................................................77 LINE INTERFACE UNIT (LIU) ........................................................................................80 13.1 13.2 LIU OPERATION..........................................................................................................................81 LIU RECEIVER ............................................................................................................................81 13.2.1 13.2.2 13.2.3 13.3 LIU TRANSMITTER ......................................................................................................................82 13.3.1 13.3.2 13.3.3 13.3.4 13.4 13.5 13.6 13.7 13.8 13.9 Receive Level Indicator........................................................................................................................ 81 Receive G.703 Section 13 Synchronization Signal ............................................................................. 82 Monitor Mode ....................................................................................................................................... 82 Transmit Short-Circuit Detector/Limiter................................................................................................ 83 Transmit Open-Circuit Detector ........................................................................................................... 83 Transmit BPV Error Insertion ............................................................................................................... 83 Transmit G.703 Section 13 Synchronization Signal (E1 Mode)........................................................... 83 MCLK PRE-SCALER ...................................................................................................................83 JITTER ATTENUATOR ..................................................................................................................83 CMI (CODE MARK INVERSION) OPTION .......................................................................................84 LIU CONTROL REGISTERS ..........................................................................................................85 RECOMMENDED CIRCUITS...........................................................................................................93 COMPONENT SPECIFICATIONS.....................................................................................................95 14. LOOPBACK CONFIGURATION.....................................................................................99 15. 64KHZ SYNCHRONIZATION INTERFACE..................................................................100 15.1 15.2 RECEIVE 64KHZ SYNCHRONIZATION INTERFACE OPERATION .....................................................100 TRANSMIT 64KHZ SYNCHRONIZATION INTERFACE OPERATION ...................................................101 G.703 Level A ................................................................................................................................................... 101 16. 16.1 16.2 17. 17.1 17.2 17.3 17.4 6312KHZ SYNCHRONIZATION INTERFACE..............................................................102 RECEIVE 6312KHZ SYNCHRONIZATION INTERFACE OPERATION .................................................102 TRANSMIT 6312KHZ SYNCHRONIZATION INTERFACE OPERATION ...............................................102 JTAG BOUNDARY SCAN ARCHITECTURE AND TEST ACCESS PORT .................103 INSTRUCTION REGISTER ...........................................................................................................107 TEST REGISTERS ......................................................................................................................108 BOUNDARY SCAN REGISTER .....................................................................................................108 BYPASS REGISTER ...................................................................................................................108 3 of 129 DS26504 T1/E1/J1/64KCC BITS Element 17.5 18. IDENTIFICATION REGISTER ........................................................................................................108 FUNCTIONAL TIMING DIAGRAMS .............................................................................111 18.1 PROCESSOR INTERFACE ...........................................................................................................111 18.1.1 18.1.2 Parallel Port Mode.............................................................................................................................. 111 SPI Serial Port Mode.......................................................................................................................... 111 19. OPERATING PARAMETERS .......................................................................................114 20. AC TIMING PARAMETERS AND DIAGRAMS ............................................................116 20.1 20.2 20.3 20.4 20.5 MULTIPLEXED BUS ....................................................................................................................116 NONMULTIPLEXED BUS .............................................................................................................119 SERIAL BUS ..............................................................................................................................122 RECEIVE SIDE AC CHARACTERISTICS .......................................................................................124 TRANSMIT SIDE AC CHARACTERISTICS .....................................................................................126 21. REVISION HISTORY ....................................................................................................128 22. PACKAGE INFORMATION ..........................................................................................129 22.1 64-PIN LQFP (56-G4019-001).................................................................................................129 4 of 129 DS26504 T1/E1/J1/64KCC BITS Element LIST OF FIGURES Figure 3-1. Block Diagram ......................................................................................................................................... 11 Figure 3-2. Loopback Mux Diagram (T1/E1 Modes Only) ......................................................................................... 12 Figure 3-3. Transmit PLL Clock Mux Diagram .......................................................................................................... 12 Figure 3-4. Master Clock PLL Diagram ..................................................................................................................... 13 Figure 13-1. Basic Network Connection .................................................................................................................... 80 Figure 13-2. Typical Monitor Application ................................................................................................................... 82 Figure 13-3. CMI Coding ........................................................................................................................................... 84 Figure 13-4. Software-Selected Termination, Metallic Protection ............................................................................. 93 Figure 13-5. Software-Selected Termination, Longitudinal Protection ...................................................................... 94 Figure 13-6. E1 Transmit Pulse Template ................................................................................................................. 96 Figure 13-7. T1 Transmit Pulse Template ................................................................................................................. 96 Figure 13-8. Jitter Tolerance (T1 Mode).................................................................................................................... 97 Figure 13-9. Jitter Tolerance (E1 Mode).................................................................................................................... 97 Figure 13-10. Jitter Attenuation (T1 Mode)................................................................................................................ 98 Figure 13-11. Jitter Attenuation (E1 Mode) ............................................................................................................... 98 Figure 15-1. 64kHz Composite Clock Mode Signal Format .................................................................................... 100 Figure 17-1. JTAG Functional Block Diagram ......................................................................................................... 103 Figure 17-2. TAP Controller State Diagram............................................................................................................. 106 Figure 18-1. SPI Serial Port Access, Read Mode, CPOL = 0, CPHA = 0 ............................................................... 111 Figure 18-2. SPI Serial Port Access, Read Mode, CPOL = 1, CPHA = 0 ............................................................... 111 Figure 18-3. SPI Serial Port Access, Read Mode, CPOL = 0, CPHA = 1 ............................................................... 111 Figure 18-4. SPI Serial Port Access, Read Mode, CPOL = 1, CPHA = 1 ............................................................... 112 Figure 18-5. SPI Serial Port Access, Write Mode, CPOL = 0, CPHA = 0 ............................................................... 112 Figure 18-6. SPI Serial Port Access, Write Mode, CPOL = 1, CPHA = 0 ............................................................... 112 Figure 18-7. SPI Serial Port Access, Write Mode, CPOL = 0, CPHA = 1 ............................................................... 113 Figure 18-8. SPI Serial Port Access, Write Mode, CPOL = 1, CPHA = 1 ............................................................... 113 Figure 20-1. Intel Bus Read Timing (BTS = 0 / BIS[1:0] = 00) ............................................................................... 117 Figure 20-2. Intel Bus Write Timing (BTS = 0 / BIS[1:0] = 00) ................................................................................ 117 Figure 20-3. Motorola Bus Timing (BTS = 1 / BIS[1:0] = 00)................................................................................... 118 Figure 20-4. Intel Bus Read Timing (BTS = 0 / BIS[1:0] = 01) ................................................................................ 120 Figure 20-5. Intel Bus Write Timing (BTS = 0 / BIS[1:0] = 01) ................................................................................ 120 Figure 20-6. Motorola Bus Read Timing (BTS = 1 / BIS[1:0] = 01) ......................................................................... 121 Figure 20-7. Motorola Bus Write Timing (BTS = 1 / BIS[1:0] = 01) ......................................................................... 121 Figure 20-8. SPI Interface Timing Diagram, CPHA = 0, BIS[1:0] = 10.................................................................... 123 Figure 20-9. SPI Interface Timing Diagram, CPHA = 1, BIS[1:0] = 10.................................................................... 123 Figure 20-10. Receive Timing—T1, E1, 64KCC Mode............................................................................................ 125 Figure 20-11. Transmit Timing—T1, E1, 64KCC Mode........................................................................................... 127 5 of 129 DS26504 T1/E1/J1/64KCC BITS Element LIST OF TABLES Table 2-1. T1-Related Telecommunications Specifications ........................................................................................ 9 Table 2-2. E1-Related Telecommunications Specifications ...................................................................................... 10 Table 5-1. LQFP Pinout ............................................................................................................................................. 22 Table 6-1. Transmit Clock Source ............................................................................................................................. 25 Table 6-2. Internal Termination.................................................................................................................................. 25 Table 6-3. E1 Line Build-Out ..................................................................................................................................... 26 Table 6-4. T1 Line Build-Out...................................................................................................................................... 26 Table 6-5. Receive Path Operating Mode ................................................................................................................. 27 Table 6-6.Transmit Path Operating Mode ................................................................................................................. 27 Table 6-7. MCLK Pre-Scaler for T1 Mode ................................................................................................................. 28 Table 6-8. MCLK Pre-Scaler for E1 Mode................................................................................................................. 28 Table 6-9. Other Operational Modes ......................................................................................................................... 29 Table 7-1. Port Mode Select ...................................................................................................................................... 30 Table 7-2. Register Map Sorted By Address ............................................................................................................. 32 Table 8-1. T1 Alarm Criterion .................................................................................................................................... 45 Table 9-1. E1 Sync/Resync Criterion......................................................................................................................... 47 Table 9-2. E1 Alarm Criterion .................................................................................................................................... 50 Table 10-1. TS_8K_4 Pin Functions.......................................................................................................................... 54 Table 10-2. RLOF_CCE Pin Functions ..................................................................................................................... 54 Table 11-1. T1 SSM Messages ................................................................................................................................. 56 Table 12-1. E1 SSM Messages ................................................................................................................................. 65 Table 13-1. Component List (Software-Selected Termination, Metallic Protection).................................................. 93 Table 13-2. Component List (Software-Selected Termination, Longitudinal Protection) .......................................... 94 Table 13-3. Transformer Specifications..................................................................................................................... 95 Table 15-1. Specification of 64kHz Clock Signal at Input Port ................................................................................ 100 Table 15-2. Specification of 64kHz Clock Signal at Output Port ............................................................................. 101 Table 16-1. Specification of 6312kHz Clock Signal at Input Port ............................................................................ 102 Table 16-2. Specification of 6312kHz Clock Signal................................................................................................. 102 Table 17-1. Instruction Codes for IEEE 1149.1 Architecture................................................................................... 107 Table 17-2. ID Code Structure................................................................................................................................. 108 Table 17-3. Device ID Codes................................................................................................................................... 108 Table 17-4. Boundary Scan Control Bits ................................................................................................................. 109 Table 19-1. Thermal Characteristics........................................................................................................................ 114 Table 19-2. Theta-JA (θJA) vs. Airflow...................................................................................................................... 114 Table 19-3. Recommended DC Operating Conditions ............................................................................................ 114 Table 19-4. Capacitance.......................................................................................................................................... 114 Table 19-5. DC Characteristics................................................................................................................................ 115 Table 20-1. AC Characteristics, Multiplexed Parallel Port....................................................................................... 116 Table 20-2. AC Characteristics, Nonmultiplexed Parallel Port ................................................................................ 119 Table 20-3. AC Characteristics, Serial Bus ............................................................................................................. 122 Table 20-4. Receive Side AC Characteristics ......................................................................................................... 124 Table 20-5. Transmit Side AC Characteristics ........................................................................................................ 126 6 of 129 DS26504 T1/E1/J1/64KCC BITS Element 1. FEATURES 1.1 General 64-pin, 10mm x 10mm LQFP package 3.3V supply with 5V tolerant inputs and outputs Evaluation kits IEEE 1149.1 JTAG Boundary Scan Driver source code available from the factory 1.2 Line Interface Requires a single master clock (MCLK) for E1, T1, or J1 operation. Master clock can be 2.048MHz, 4.096MHz, 8.192MHz, 12.8MHz (available in CPU-interface mode only), or 16.384MHz. Option to use 1.544MHz, 3.088MHz, 6.176MHz, or 12.552MHz for T1-only operation. Fully software configurable Short- and long-haul applications Automatic receive sensitivity adjustments Ranges include 0dB to -43dB or 0dB to -12dB for E1 applications; 0dB to -36dB or 0dB to -15dB for T1 applications Receive level indication in 2.5dB steps from -42.5dB to -2.5dB Internal receive termination option for 75Ω, 100Ω, 110Ω, 120Ω, and 133Ω lines Monitor application gain settings of 20dB, 26dB, and 32dB G.703 receive-synchronization signal mode Flexible transmit-waveform generation T1 DSX-1 line build-outs E1 waveforms include G.703 waveshapes for both 75Ω coax and 120Ω twisted cables AIS generation independent of loopbacks Alternating ones and zeros generation Square-wave output Open-drain output option Transmitter power-down Transmitter 50mA short-circuit limiter with exceeded indication of current limit Transmit open-circuit-detected indication 1.3 Jitter Attenuator (T1/E1 Modes Only) 32-bit or 128-bit crystal-less jitter attenuator Requires only a 2.048MHz master clock for both E1 and T1 operation with the option to use 1.544MHz for T1 operation Can be placed in either the receive or transmit path or disabled Limit trip indication 7 of 129 DS26504 T1/E1/J1/64KCC BITS Element 1.4 Framer/Formatter Fully independent transmit and receive functionality Full receive and transmit path transparency T1 framing formats include D4 and ESF Detailed alarm and status reporting with optional interrupt support RCL, RLOS, and RAIS alarms interrupt on change of state Japanese J1 support includes: − Ability to calculate and check CRC6 according to the Japanese standard − Ability to generate yellow alarm according to the Japanese standard 1.5 Test and Diagnostics Remote and local loopback 1.6 Control Port 8-bit parallel or serial control port Multiplexed or nonmultiplexed buses Intel or Motorola formats Supports polled or interrupt-driven environments Software access to device ID and silicon revision Software-reset supported Automatic clear on power-up Flexible register space resets Hardware reset pin 8 of 129 DS26504 T1/E1/J1/64KCC BITS Element 2. SPECIFICATIONS COMPLIANCE The DS26504 meets all applicable sections of the latest telecommunications specifications including those listed in the following tables. Table 2-1. T1-Related Telecommunications Specifications ANSI T1.102: Digital Hierarchy Electrical Interface ANSI T1.231: Digital Hierarchy–Layer 1 In-Service Performance Monitoring ANSI T1.403: Network and Customer Installation Interface–DS1 Electrical Interface TR62411 (ANSI) “Digital Hierarchy–Electrical Interfaces” (ANSI) “Digital Hierarchy–Formats Specification” (ANSI) “Digital Hierarchy–Layer 1 In-Service Digital Transmission Performance Monitoring” (ANSI) “Network and Customer Installation Interfaces – DS1 Electrical Interface” (AT&T) “Requirements for Interfacing Digital Terminal Equipment to Services Employing the Extended Super frame Format” (AT&T) “High Capacity Digital Service Channel Interface Specification” (TTC) “Frame Structures on Primary and Secondary Hierarchical Digital Interfaces” (TTC) “ISDN Primary Rate User-Network Interface Layer 1 Specification” 9 of 129 DS26504 T1/E1/J1/64KCC BITS Element Table 2-2. E1-Related Telecommunications Specifications ITUT G.703 Physical/Electrical Characteristics of G.703 Hierarchical Digital Interfaces ITUT G.736 Characteristics of Synchronous Digital Multiplex Equipment operating at 2048kbps ITUT G.742 Second-Order Digital Multiplex Equipment Operating at 8448kbps ITUT G.772 ITUT G.775 ITUT G.823 The control of jitter and wander within digital networks, which are based on 2.048kbps hierarchy ETSI 300 233 (ITU) “Synchronous Frame Structures used at 1544, 6312k, 2048, 8488, and 44,736kbps Hierarchical Levels” (ITU) “Frame Alignment and Cyclic Redundancy Check (CRC) Procedures Relating to Basic Frame Structures Defined in Recommendation G.704” (ITU) “Characteristics of primary PCM Multiplex Equipment Operating at 2048kbps” (ITU) Characteristics of a synchronous digital multiplex equipment operating at 2048kbps” (ITU) “Loss Of Signal (LOS) and Alarm Indication Signal (AIS) Defect Detection and Clearance Criterion” (ITU) “The Control of Jitter and Wander Within Digital Networks Which are Based on the 2048kbps Hierarchy” (ITU) “Primary Rate User-Network Interface – Layer 1 Specification” (ITU) “Error Performance Measuring Equipment Operating at the Primary Rate and Above” (ITU) “In-service code violation monitors for digital systems” (ETSI) “Integrated Services Digital Network (ISDN); Primary rate User-Network Interface (UNI); Part 1/ Layer 1 specification” (ETSI) “Transmission and multiplexing; Physical/electrical characteristics of hierarchical digital interfaces for equipment using the 2048kbps-based plesiochronous or synchronous digital hierarchies” (ETSI) “Integrated Services Digital Network (ISDN); Access digital section for ISDN primary rate” (ETSI) “Integrated Services Digital Network (ISDN); Attachment requirements for terminal equipment to connect to an ISDN using ISDN primary rate access” (ETSI) “Business Telecommunications (BT); Open Network Provision (ONP) technical requirements; 2048lkbps digital unstructured leased lines (D2048U) attachment requirements for terminal equipment interface” (ETSI) “Business Telecommunications (BTC); 2048kbps digital structured leased lines (D2048S); Attachment requirements for terminal equipment interface” (ITU) “Synchronous Frame Structures used at 1544, 6312, 2048, 8488, and 44,736kbps Hierarchical Levels” (ITU) “Frame Alignment and Cyclic Redundancy Check (CRC) Procedures Relating to Basic Frame Structures Defined in Recommendation G.704” 10 of 129 DS26504 T1/E1/J1/64KCC BITS Element 3. BLOCK DIAGRAMS Figure 3-1. Block Diagram MCLK DS26504 JA CLOCK MASTER CLOCK RTIP RRING RX RX LIU LIU RLOS TNEGO TPOSO TRING - DATA L O C A L L O O P B A C K RAIS TTIP CLOCK + DATA TX LIU M U X JA ENABLED AND IN RX PATH JITTER ATTENUATOR CAN BE ASSIGNED TO RECEIVE OR TRANSMIT PATH OR DISABLED JA ENABLED AND IN TX PATH RCLK LOF_CCE R E M O T E L O O P B A C K T1/E1 SSM FRAMER 64KCC DECODER RSER RS_8K 400HZ PLL CLOCK MUX TCLK PLL_OUT TX CLOCK M U X + DATA T1/E1 SSM FORMATTER - DATA 64KCC CODER TSER TS_8K_4 THZE TCLKO PARALLEL/SERIAL CPU I/F HARDWARE CONTROLLER JTAG JTAG PORT PORT JTMS JTRST JTCLK JTDI JTDO BIS1 PARALLEL, SERIAL, OR HARDWARE CONTROLLER 11 of 129 BIS0 TSTRST DS26504 T1/E1/J1/64KCC BITS Element Figure 3-2. Loopback Mux Diagram (T1/E1 Modes Only) CLOCK FROM RX LIU RCLK JITTER ATTENUATOR ENABLED AND IN RX PATH + DATA TO RX FRAMER + DATA - DATA - DATA LOCAL LOOPBACK (LBCR.3) TX CLOCK CLOCK TO TX LIU JITTER ATTENUATOR ENABLED AND IN TX PATH + DATA + DATA FROM TX FORMATTER - DATA - DATA REMOTE LOOPBACK (LBCR.4) Figure 3-3. Transmit PLL Clock Mux Diagram TPCR.3 TPCR.4 TPCR.6 TPCR.7 IN SEL OUT SEL TPCR.5 TPCR.2 RECOVERED CLOCK TCLK PIN PLL_OUT PIN TX PLL OUTPUT = 8kHz 19.44MHz TX CLOCK JA CLOCK TPCR.0 (TCSS0) (HARDWARE MODE PIN NAME) 12 of 129 TPCR.1 (TCSS1) DS26504 T1/E1/J1/64KCC BITS Element Figure 3-4. Master Clock PLL Diagram 13 of 129 DS26504 T1/E1/J1/64KCC BITS Element 4. PIN FUNCTION DESCRIPTION 4.1 Transmit PLL NAME TYPE PLL_OUT O TCLK I FUNCTION Transmit PLL Output. This pin can be selected to output the 1544kHz, 2048kHz, 64kHz, or 6312kHz output from the internal TX PLL or the internal signal, TX CLOCK. See Figure 3-3 and Figure 3-4. Transmit Clock Input. A 64kHz, 1.544MHz, 2.048MHz, or 6312kHz primary clock. May be selected by the TX PLL mux to either directly drive the transmit section or be converted to one of the other rates prior to driving the transmit section. See Figure 3-3 and Figure 3-4. 4.2 Transmit Side NAME TYPE TSER I FUNCTION Transmit Serial Data. Source of transmit data sampled on the falling edge of TX CLOCK (an internal signal). See Figure 3-1, Figure 3-3, and the transmit timing diagram (Figure 20-11). TSYNC, 8kHz Sync, 400Hz Sync. See Figure 3-1 and the transmit timing diagram (Figure 20-11). T1/E1 Mode: In input mode, this pin is sampled on the falling edge of TX CLOCK (an internal signal) and a pulse at this pin will establish either frame or multiframe boundaries for the transmit side. TS_8K_4 I/O In output mode, this pin is updated on the rising edge of TX CLOCK (an internal signal) and can be programmed to output a frame or multiframe sync pulse useful for aligning data. 64KCC Mode: In input mode, this pin is sampled on the falling edge of TX CLOCK (an internal signal) and will establish the boundary for the 8kHz portion of the Composite Clock or the 400Hz boundary based on the setting of IOCR1.3. In output mode, this pin is updated on the rising edge of TX CLOCK (an internal signal) and will indicate the 8kHz or 400Hz composite clock alignment. Transmit Clock Output. Buffered clock that is used to clock data through the transmit-side formatter (i.e., either TCLK or RCLK). TCLKO O TPOSO O TNEGO O Payload Mode: When payload mode is enabled, this pin outputs a gapped clock based on the signal selected for transmit clock. In T1 operation, the clock is gapped during the F-bit position. In E1 mode, the clock is gapped during time slots 0 and 16. Transmit Positive-Data Output. In T1 or E1 mode, updated on the rising edge of TCLKO with the bipolar data out of the transmit-side formatter. Can be programmed to source NRZ data via the output-data format (IOCR1.0) control bit. In 64KCC or 6312kHz mode this pin will be low. Transmit Negative-Data Output. In T1 or E1 mode, updated on the rising edge of TCLKO with the bipolar data out of the transmit-side formatter. In 64KCC or 6312kHz mode this pin is low. 14 of 129 DS26504 T1/E1/J1/64KCC BITS Element 4.3 Receive Side NAME TYPE RCLK O RS_8K O 400HZ O RSER O RLOF_CCE O RLOS O FUNCTION Receive Clock. Recovered 1.544MHz (T1), 2.048MHz (E1), 6312 kHz (G.703 Synchronization Interface), or 64kHz (Composite Clock) clock. Payload Mode: When payload mode is enabled, this pin outputs a gapped clock based on the internal RCLK. In T1 operation, the clock is gapped during the Fbit position. In E1 mode, the clock is gapped during time slots 0 and 16. Receive Sync/8kHz Clock T1/E1 Mode: An extracted pulse, one RCLK wide, is output at this pin that identifies either frame (IOCR1.5 = 0) or multiframe (IOCR1.5 = 1) boundaries. If set to output frame boundaries, then through IOCR1.6, RS_8K can also be set to output double-wide pulses on signaling frames in T1 mode. 64KCC Mode: This pin outputs the extracted 8kHz portion of the composite clock signal. 6312kHz Mode: This pin is in a high-impedance state. 400Hz Clock Output T1/E1 Mode: This pin is in a high-impedance state. 64KCC Mode: This pin outputs the 400Hz clock if enabled. 6312kHz Mode: This pin is in a high-impedance state. Receive Serial Data T1/E1 Mode: This is the received NRZ serial data updated on the rising edges of RCLK. 64KCC Mode: This pin is in a high-impedance state. 6312kHz Mode: This pin is in a high-impedance state. Receive Loss of Frame or Composite Clock Error. This output can be configured to be a Loss-of-Transmit Clock indicator via IOCR.4 when operating in T1 or E1 mode. T1/E1 Mode: Set when the receive synchronizer is searching for frame alignment (RLOF mode), or set when the signal at the TCLK pin has not transitioned for approximately 15 periods of the scaled MCLK (LOTC mode). 64KCC Mode: Active high when errors are detected in the 8kHz clock or 400Hz clock. 6312kHz Mode: This pin is in a high-impedance state. Receive Loss of Signal T1 Mode: High when 192 consecutive zeros detected. E1 Mode: High when 255 consecutive zeros detected. 64KCC Mode: High when consecutive zeros detected for a minimum of 120μs or the input signal falls below 0.3vp. 6312kHz Mode: High when consecutive zeros detected for a minimum of 60μs. 15 of 129 DS26504 T1/E1/J1/64KCC BITS Element NAME TYPE RAIS O FUNCTION Receive Alarm Indication Signal T1 Mode: Toggles high when the receive Blue Alarm is detected. E1 Mode: Toggles high when the receive AIS is detected. 64KCC Mode: This pin is in a high-impedance state. 6312kHz Mode: This pin is in a high-impedance state. 4.4 Controller Interface NAME TYPE INT/ JACKS0 I/O TMODE1 I TMODE2 I TSTRST I BIS[1:0] I AD[7]/ RITD I/O FUNCTION Active-Low Interrupt/Jitter Attenuator Clock Select 0 INT: Flags host controller during events, alarms, and conditions defined in the status registers. Active-low open-drain output. JACKS0: Hardware Mode: Jitter Attenuator Clock Select 0. Set this pin high for T1 mode operation when either a 2.048MHz, 4.096MHz, 8.192MHz, or 16.382MHz signal is applied at MCLK. Transmit Mode Select 1. In Hardware Mode (BIS[1:0] = 11), this bit is used to configure the transmit operating mode. Transmit Mode Select 2. In Hardware Mode (BIS[1:0] = 11), this bit is used to configure the transmit operating mode. Three-State Control and Device Reset. A dual-function pin. A zero-to-one transition issues a hardware reset to the DS26504 register set. Configuration register contents are set to the default state. Leaving TSTRST high three-states all output and I/O pins (including the parallel control port). Set low for normal operation. Useful for in-board level testing. Bus Interface Mode Select 1, 0. These bits select the processor interface mode of operation. BIS[1:0] : 00 = Parallel Port Mode (Multiplexed) 01 = Parallel Port Mode (Nonmultiplexed) 10 = Serial Port Mode 11 = Hardware Mode Data Bus D[7] or Address/Data Bus AD[7]/Receive Internal Termination Disable A[7]: In nonmultiplexed bus operation (BIS[1:0] = 01), it serves as the data bus D[7]. AD[7]: In multiplexed bus operation (BIS[1:0] = 00), it serves as the multiplexed address/data bus AD[7]. RITD: In Hardware Mode (BIS[1:0] = 11), internal receive termination is disabled when RITD = 1. 16 of 129 DS26504 T1/E1/J1/64KCC BITS Element NAME TYPE AD[6]/ TITD I/O AD[5]/ RMODE1 AD[4]/ RMODE0 FUNCTION Data Bus D[6] or Address/Data Bus AD[6]/Transmit Internal Termination Disable A[6]: In nonmultiplexed bus operation (BIS[1:0] = 01), it serves as the data bus D[6]. AD[6]: In multiplexed bus operation (BIS[1:0] = 00), it serves as the multiplexed address/data bus AD[6]. TITD: In Hardware Mode (BIS[1:0] = 11), internal transmit termination is disabled when TITD = 1. Data Bus D[5] or Address/Data Bus AD[5]/Receive Framing Mode Select Bit 1 A[5]: In nonmultiplexed bus operation (BIS[1:0] = 01), it serves as the data bus D[5]. I/O AD[5]: In multiplexed bus operation (BIS[1:0] = 00), it serves as the multiplexed address/data bus AD[5]. RMODE1: In Hardware Mode (BIS[1:0] = 11), it selects the receive side operating mode. Data Bus D[4] or Address/Data Bus AD[4]/Receive Framing Mode Select Bit 0 A[4]: In nonmultiplexed bus operation (BIS[1:0] = 01), it serves as the data bus D[4]. I/O AD[4]: In multiplexed bus operation (BIS[1:0] = 00), it serves as the multiplexed address/data bus AD[4]. RMODE0: In Hardware Mode (BIS[1:0] = 11), it selects the receive side operating mode. Data Bus D[3] or Address/Data Bus AD[3]/TS_8K_4 Mode Select A[3]: In nonmultiplexed bus operation (BIS[1:0] = 01), it serves as the data bus D[3]. AD[3]/ TSM I/O AD[3]: In multiplexed bus operation (BIS[1:0] = 00), it serves as the multiplexed address/data bus AD[3]. TSM: In Hardware Mode (BIS[1:0] = 11), this pin selects the function of TS_8K_4. See the register descriptions for more detailed information. Data Bus D[2] or Address/Data Bus AD[2]/RS_8K Mode Select/Serial Clock A[2]: In nonmultiplexed bus operation (BIS[1:0] = 01), it serves as the data bus D[2]. AD[2]/ RSM/SCLK I/O AD[2]: In multiplexed bus operation (BIS[1:0] = 00), it serves as the multiplexed address/data bus AD[2]. RSM: In Hardware Mode (BIS[1:0] = 11), this pin selects the function of RS_8K. See the register descriptions for more detailed information. SCLK: In Serial Port Mode, this pin is the serial clock input. 17 of 129 DS26504 T1/E1/J1/64KCC BITS Element NAME TYPE AD[1]/ RMODE3/ MOSI I/O AD[0]/ TCSS0/ MISO FUNCTION Data Bus D[1] or Address/Data Bus AD[1]/Receive Mode Select 3/Master Out-Slave In A[1]: In nonmultiplexed bus operation (BIS[1:0] = 01), it serves as the data bus D[1]. AD[1]: In multiplexed bus operation (BIS[1:0] = 00), it serves as the multiplexed address/data bus AD[1]. RMODE3: In Hardware Mode (BIS[1:0] = 11), this pin selects the receive side operating mode. MOSI: Serial data input called Master Out-Slave In for clarity of data transfer direction. Data Bus D[0] or Address/Data Bus AD[0]/Transmit Clock Source Select 0/Master In-Slave Out A[0]: In nonmultiplexed bus operation (BIS[1:0] = 01), it serves as the data bus D[0]. I/O AD[0]: In multiplexed bus operation (BIS[1:0] = 00), it serves as the multiplexed address/data bus AD[0]. TCSS0: Transmit Clock Source Select 0. MISO (output): In serial bus mode (BIS[1:0] = 10), this pin serves as the serial data output Master In-Slave Out. TCSS1 A6/ MPS0 A5/CPOL/ TMODE0 I Transmit Clock Source Select 1 I Address Bus Bit A[6]/MCLK Prescale Select 0 A6: In nonmultiplexed bus operation (BIS[1:0] = 01), this pin serves as A[6]. In multiplexed bus operation (BIS[1:0] = 00), these pins are not used and should be tied low. I MPS0: In Hardware Mode (BIS[1:0] = 11), MCLK prescale select is used to set the prescale value for the PLL. Address Bus Bit A[5]/Serial Port Clock Polarity Select/Transmit Mode Select 0 A5: In nonmultiplexed bus operation (BIS[1:0] = 01), this pin serves as A[5]. In multiplexed bus operation (BIS[1:0] = 00), these pins are not used and should be tied low. CPOL: In Serial Port Mode (BIS[1:0] = 10), this pin selects the serial port clock polarity. See the functional timing diagrams for the Serial Port Interface. TMODE0: In Hardware Mode (BIS[1:0] = 11), this pin is used to configure the transmit operating mode. 18 of 129 DS26504 T1/E1/J1/64KCC BITS Element NAME TYPE A4/CPHA/ L2 I FUNCTION Address Bus Bit A[4]/Serial Port Clock Phase Select/Line Build-Out Select 2 A4: In nonmultiplexed bus operation (BIS[1:0] = 01), this pin serves as A[4]. In multiplexed bus operation (BIS[1:0] = 00), these pins are not used and should be tied low. CPHA: In Serial Port Mode (BIS[1:0] = 10), this pin selects the serial port clock phase. See the functional timing diagrams for the Serial Port Interface. A3/ L1 A2/ L0 A1/ TAIS A0/ E1TS BTS/ HBE I I L2: In Hardware Mode (BIS[1:0] = 11), this pin selects the line build-out value. Address Bus Bit A[3]/Line Build-Out Select 1 A3: In nonmultiplexed bus operation (BIS[1:0] = 01), this pin serves as A[3]. In multiplexed bus operation (BIS[1:0] = 00), these pins are not used and should be tied low. L1: In Hardware Mode (BIS[1:0] = 11), this pin selects the line build-out value. Address Bus Bit A[2]/Line Build-Out Select 0 A2: In nonmultiplexed bus operation (BIS[1:0] = 01), this pin serves as A[2]. In multiplexed bus operation (BIS[1:0] = 00), these pins are not used and should be tied low. L0: In Hardware Mode (BIS[1:0] = 11), this pin selects the line build-out value. Address Bus Bit A[1]/Transmit AIS A1: In nonmultiplexed bus operation (BIS[1:0] = 01), this pin serves as A[1]. In multiplexed bus operation (BIS[1:0] = 00), these pins are not used and should be tied low. I I I TAIS: When set to 0 and in T1/E1 operating modes, the transmitter transmits an AIS pattern. Set to 1 for normal operation. TAIS (64KCC): When set = 0 and in any 64KCC mode, the device transmits an all-ones signal without BPVs. When set = 1, normal 64KCC transmission is enabled. Address Bus Bit A[0]/E1 Termination Select A0: In nonmultiplexed bus operation (BIS[1:0] = 01), this pin serves as A[0]. In multiplexed bus operation (BIS[1:0] = 00), these pins are not used and should be tied low. E1TS: In Hardware Mode (BIS[1:0] = 11), this pin selects the E1 internal termination value (0 = 75Ω, 1 = 120Ω). Bus Type Select/Transmit and Receive B8ZS/HDB3 Enable BTS: Strap high to select Motorola bus timing; strap low to select Intel bus timing. This pin controls the function of the RD (DS), ALE (AS), and WR (R/W) pins. If BTS = 1, then these pins assume the function listed in parentheses (). HBE: In Hardware Mode (BIS[1:0] = 11), this pin enables transmit and receive B8ZS/HDB3 when in T1/E1 operating modes. 19 of 129 DS26504 T1/E1/J1/64KCC BITS Element NAME TYPE RD(DS)/ RMODE2 I CS/ RLB I ALE (AS)/ A7/MPS1 I WR (R/W)/ TMODE3 FUNCTION Active-Low Read Input-Data Strobe/Receive Mode Select Bit 2 RD (DS): DS is active high when BIS[1:0] = 01. See the bus timing diagrams. RMODE2: In Hardware Mode (BIS[1:0] = 11), this pin selects the receive side operating mode. Active-Low Chip Select/Remote Loopback Enable CS: This active-low signal must be low to read or write to the device. This signal is used for both the parallel port and the serial port modes. RLB: In Hardware Mode (BIS[1:0] = 11), when high, remote loopback is enabled. This function is only valid when the transmit side and receive side are in the same operating mode. Address Latch Enable (Address Strobe)/Address Bus Bit 7/MCLK Prescale Select 1 ALE (AS): In multiplexed bus operation (BIS[1:0] = 00), this pin serves to demultiplex the bus on a positive-going edge. A7: In nonmultiplexed bus operation (BIS[1:0] = 01), this pin serves as A[7]. I MPS1: In Hardware Mode (BIS[1:0] = 11), MCLK prescale select is used to set the prescale value for the PLL. Active-Low Write Input (Read/Write)/Transmit Mode Select 3 WR: In Processor Mode, this pin is the active-low write signal. TMODE3: In Hardware Mode, this pin selects the transmit-side operating mode. 4.5 JTAG NAME TYPE JTCLK I JTMS I JTDI I JTDO O JTRST I FUNCTION JTAG Clock. This clock input is typically a low frequency (less than 10MHz) 50% duty cycle clock signal. JTAG Mode Select (with pullup). This input signal is used to control the JTAG controller state machine and is sampled on the rising edge of JTCLK. JTAG Data Input (with pullup). This input signal is used to input data into the register that is enabled by the JTAG controller state machine and is sampled on the rising edge of JTCLK. JTAG Data Output. This output signal is the output of an internal scan shift register enabled by the JTAG controller state machine and is updated on the falling edge of JTCLK. The pin is in the high-impedance mode when a register is not selected or when the JTRST signal is high. The pin goes into and exits the high-impedance mode after the falling edge of JTCLK. Active-Low JTAG Reset. This input forces the JTAG controller logic into the reset state and forces the JTDO pin into high impedance when low. This pin should be low while power is applied and set high after the power is stable. The pin can be driven high or low for normal operation, but must be high for JTAG operation. 20 of 129 DS26504 T1/E1/J1/64KCC BITS Element 4.6 Line Interface NAME TYPE MCLK I RTIP I RRING I TTIP O TRING O THZE I FUNCTION Master Clock Input. A (50ppm) clock source. This clock is used internally for both clock/data recovery and the jitter attenuator for both T1 and E1 modes. A quartz crystal can be applied across MCLK and XTALD rather than the clock source. The clock rate can be 16.384MHz, 8.192MHz, 4.096MHz, or 2.048MHz. When using the DS26504 in T1-only operation, a 1.544MHz (50ppm) clock source can be used. Receive Tip. Analog input for clock recovery circuitry. This pin connects via a 1:1 transformer to the network. See the Line Interface Unit section for details. Receive Ring. Analog input for clock recovery circuitry. This pin connects via a 1:1 transformer to the network. See the Line Interface Unit section for details. Transmit Tip. Analog line-driver output. This pin connects via a 1:2 step-up transformer to the network. See the Line Interface Unit section for details. Transmit Ring. Analog line-driver output. This pin connects via a 1:2 step-up transformer to the network. See the Line Interface Unit section for details. Transmit High-Impedance Enable. When high, TTIP and TRING will be placed into a high-impedance state. 4.7 Power NAME TYPE DVDD — RVDD — TVDD — DVSS — RVSS — TVSS — FUNCTION Digital Positive Supply. 3.3V ±5%. Should be tied to the RVDD and TVDD pins. Receive Analog Positive Supply. 3.3V ±5%. Should be tied to the DVDD and TVDD pins. Transmit Analog Positive Supply. 3.3V ±5%. Should be tied to the DVDD and RVDD pins. Digital Signal Ground. 0.0V. Should be tied to the RVSS and TVSS pins. Receive Analog Signal Ground. 0.0V. Should be tied to the DVSS and TVSS pins. Transmit Analog Signal Ground. 0.0V. Should be tied to the DVSS and RVSS pins. 21 of 129 DS26504 T1/E1/J1/64KCC BITS Element 5. PINOUT Table 5-1. LQFP Pinout PIN TYPE PARALLEL PORT MODE SERIAL PORT 1 I/O AD2 SCLK RSM 2 I/O AD3 — TSM 3 I/O AD4 — RMODE0 4 I/O AD5 — RMODE1 5 I/O AD6 — TITD 6 I/O AD7 — RITD I DVDD DVDD DVDD Digital Positive Supply I DVSS DVSS DVSS Digital Signal Ground 9 I A0 — E1TS 10 I A1 — TAIS 11 I A2 — L0 12 I A3 — L1 13 I A4 CPHA L2 14 I A5 CPOL TMODE0 15 I A6 — MPS0 16 I ALE (AS)/A7 — MPS1 17 I TCLK TCLK TCLK 7, 24, 58 8, 22, 56 HARDWARE 22 of 129 FUNCTION Parallel Port Mode: Address/Data Bus Bit 2 Serial Port Mode: Serial Clock Hardware Mode: RS_8K Mode Select Parallel Port Mode: Address/Data Bus Bit 3 Serial Port Mode: Unused, should be connected to VSS. Hardware Mode: TS_8K_4 Mode Select Parallel Port Mode: Address/Data Bus Bit 4 Serial Port Mode: Unused, should be connected to VSS. Hardware Mode: Receive Mode Select 0 Parallel Port Mode: Address/Data Bus Bit 5 Serial Port Mode: Unused, should be connected to VSS. Hardware Mode: Receive Mode Select 1 Parallel Port Mode: Address/Data Bus Bit 6 Serial Port Mode: Unused, should be connected to VSS. Hardware Mode: Transmit Internal Termination Disable Parallel Port Mode: Address/Data Bus Bit 7 Serial Port Mode: Unused, should be connected to VSS. Hardware Mode: Receive Internal Termination Disable Parallel Port Mode: Address Bus Bit 0 Serial Port Mode: Unused, should be connected to VSS. Hardware Mode: E1 Internal Termination Select Parallel Port Mode: Address Bus Bit 1 Serial Port Mode: Unused, should be connected to VSS. Hardware Mode: Transmit AIS Parallel Port Mode: Address Bus Bit 2 Serial Port Mode: Unused, should be connected to VSS. Hardware Mode: Line Build-Out Select 0 Parallel Port Mode: Address Bus Bit 3 Serial Port Mode: Unused, should be connected to VSS. Hardware Mode: Line Build-Out Select 1 Parallel Port Mode: Address Bus Bit 4 Serial Port Mode: Serial Port Clock Phase Select Hardware Mode: Line Build-Out Select 2 Parallel Port Mode: Address Bus Bit 5 Serial Port Mode: Serial Port Clock Polarity Select Hardware Mode: Transmit Mode Select 0 Parallel Port Mode: Address Bus Bit 6 Serial Port Mode: Unused, should be connected to VSS. Hardware Mode: MCLK Prescaler Select 0 Parallel Port Mode: Address Latch Enable/Address Bus Bit 7 Serial Port Mode: Unused, should be connected to VSS. Hardware Mode: MCLK Prescaler Select 1 External Transmit Clock Input DS26504 T1/E1/J1/64KCC BITS Element O O O I PARALLEL PORT TCLKO TNEGO TPOSO TSER MODE SERIAL PORT TCLKO TNEGO TPOSO TSER 23 I/O TS_8K_4 TS_8K_4 TS_8K_4 25 O RCLK RCLK RCLK 26 O RS_8K RS_8K RS_8K 27 28 29 30 O O O O 400HZ RSER RAIS RLOF_CCE 400HZ RSER RAIS RLOF_CCE 400HZ RSER RAIS RLOF_CCE 31 I — — TCSS1 32 33 34 35 36 37 38 39 40, 43, 45 41 42 44 O I I I I O I I RLOS JTMS JTCLK JTRST JTDI JTDO RVDD TSTRST RLOS JTMS JTCLK JTRST JTDI JTDO RVDD TSTRST RLOS JTMS JTCLK JTRST JTDI JTDO RVDD TSTRST I RVSS RVSS RVSS I I I RTIP RRING MCLK RTIP RRING MCLK RTIP RRING MCLK 46 I/O INT INT JACKS0 47 O PLL_OUT PLL_OUT PLL_OUT 48 I — — TMODE2 49 I — — TMODE1 50 51 52 53 54 I O I I O THZE TTIP TVSS TVDD TRING THZE TTIP TVSS TVDD TRING THZE TTIP TVSS TVDD TRING 55 I BTS — HBE 57 I BIS0 BIS0 BIS0 PIN TYPE 18 19 20 21 HARDWARE TCLKO TNEGO TPOSO TSER 23 of 129 FUNCTION Transmit Clock Output Transmit Negative-Data Output Transmit Positive-Data Output Transmit Serial Data T1/E1 Mode: Transmit Frame/Multiframe Sync 64KCC Mode: Transmit 8kHz or 400Hz Sync Receive Clock T1/E1 Mode: Receive Frame/Multiframe Boundary 64KCC Mode: Receive 8kHz Output 400Hz Output in Composite Clock Mode Receive Serial Data Receive Alarm Indication Signal Receive Loss of Frame_Composite Clock Error Parallel Port Mode: Unused, should be connected to VSS. Serial Port Mode: Unused, should be connected to VSS. Hardware Mode: Transmit Clock Source Select 1 Receive Loss of Signal IEEE 1149.1 Test Mode Select IEEE 1149.1 Test Clock Signal IEEE 1149.1 Test Reset IEEE 1149.1 Test Data Input IEEE 1149.1 Test Data Output Receive Analog Positive Supply Test/Reset Receive Analog Signal Ground Receive Analog Tip Input Receive Analog Ring Input Master Clock Input Parallel Port Mode: Interrupt Serial Port Mode: Interrupt Hardware Mode: Jitter Attenuator Clock Select 0 Transmit PLL (TX PLL) Clock Output Parallel Port Mode: Unused, should be connected to VSS. Serial Port Mode: Unused, should be connected to VSS. Hardware Mode: Transmit Mode Select 2 Parallel Port Mode: Unused, should be connected to VSS. Serial Port Mode: Unused, should be connected to VSS. Hardware Mode: Transmit Mode Select 1 Transmit High-Impedance Enable Transmit Analog Tip Output Transmit Analog Signal Ground Transmit Analog Positive Supply Transmit Analog Ring Output Parallel Port Mode: Bus Type Select (Motorola/Intel) Serial Port Mode: Unused, should be connected to VSS. Hardware Mode: Receive and Transmit HDB3/B8ZS Enable Bus Interface Select Mode 0 DS26504 T1/E1/J1/64KCC BITS Element MODE SERIAL PORT BIS1 HARDWARE I PARALLEL PORT BIS1 60 I CS CS RLB 61 I RD (DS) — RMODE2 62 I WR (R/W) — TMODE3 63 I/O AD0 MISO TCSS0 64 I/O AD1 MOSI RMODE3 PIN TYPE 59 BIS1 24 of 129 FUNCTION Bus Interface Select Mode 1 Parallel Port Mode: Chip Select (Active Low) Serial Port Mode: Chip Select (Active Low) Hardware Mode: Remote Loopback Enable Parallel Port Mode: Read Input (Data Strobe), Active Low Serial Port Mode: Unused, should be connected to VSS. Hardware Mode: Receive Mode Select 2 Parallel Port Mode: Write Input (Read/Write), Active Low Serial Port Mode: Unused, should be connected to VSS. Hardware Mode: Transmit Mode Select 3 Parallel Port Mode: Address/Data Bus Bit 0 Serial Port Mode: Serial Data Out (Master In-Slave Out) Hardware Mode: Transmit Clock Source Select 0 Parallel Port Mode: Address/Data Bus Bit 1 Serial Port Mode: Serial Data In (Master Out-Slave In) Hardware Mode: Receive Mode Select 3 DS26504 T1/E1/J1/64KCC BITS Element 6. HARDWARE CONTROLLER INTERFACE In Hardware Controller mode, the parallel and serial port pins are reconfigured to provide direct access to certain functions in the port. Only a subset of the device’s functionality is available in hardware mode. Each register description throughout the data sheet indicates the functions that may be controlled in hardware mode and several alarm indicators that are available in both hardware and processor mode. Also indicated are the fixed states of the functions not controllable in hardware mode. 6.1 Transmit Clock Source Refer to Figure 3-3. In Hardware Controller mode, the input to the TX PLL is always TCLK PIN. TX CLOCK is selected by the TCSS0 and TCSS1 pins, as shown in Table 6-1. The PLL_OUT pin is always the same signal as select for TX CLOCK. If the user wants to slave the transmitter to the recovered clock, then the RCLK pin must be tied to the TCLK pin externally. Table 6-1. Transmit Clock Source TCSS1 PIN 31 TCSS0 PIN 63 0 0 The TCLK pin is the source of transmit clock. 0 1 The PLL_CLK is the source of transmit clock. 1 0 The scaled signal present at MCLK as the transmit clock. 1 1 The signal present at RCLK is the transmit clock. TRANSMIT CLOCK SOURCE 6.2 Internal Termination In Hardware Controller mode, the internal termination is automatically set according to the receive or transmit mode selected. It can be disabled via the TITD and RITD pins. If internal termination is enabled in E1 mode, the E1TS pin is use to select 75Ω or 120Ω termination. The E1TS pin applies to both transmit and receive. Table 6-2. Internal Termination PIN TITD PIN 5 RITD PIN 6 E1TS PIN 9 FUNCTION Transmit Internal Termination Disable. Disables the internal transmit termination. The internal transmit termination value is dependent on the state of the TMODEx pins. 0 = internal transmit termination enabled 1 = internal transmit termination disabled Receive Internal Termination Disable. Disables the internal receive termination. The internal receive termination value is dependent on the state of the RMODEx pins. 0 = internal receive termination enabled 1 = internal receive termination disabled E1 Termination Select. Selects 120Ω or 75Ω internal termination when one of the E1 modes is selected and internal termination is enabled. If E1 is selected for both transmit and receive, then both terminations will be the same. 0 = 75Ω 1 = 120Ω 25 of 129 DS26504 T1/E1/J1/64KCC BITS Element 6.3 Line Build-Out Table 6-3. E1 Line Build-Out L2 PIN 13 0 0 1 1 L1 PIN 12 0 0 0 0 L0 PIN 11 0 1 0 1 1 1 0 1 1 1 APPLICATION 75Ω normal 120Ω normal 75Ω with high return loss (Note 2) 120Ω with high return loss (Note 2) 75Ω normal + enable transmit and receive gapped clock 120Ω normal + enable transmit and receive gapped clock N (Note 1) 1:2 1:2 1:2 1:2 RETURN LOSS N.M. N.M. 21dB 21dB Rt (Note 1) 0 0 6.2Ω 11.6Ω 1:2 N.M 0 1:2 N.M 0 N (Note 1) 1:2 1:2 1:2 1:2 1:2 — — RETURN LOSS N.M. N.M. N.M. N.M. N.M. — — Rt (Note 1) 0 0 0 0 0 — — 1:2 N.M. 0 Table 6-4. T1 Line Build-Out L2 PIN 13 0 0 0 0 1 1 1 L1 PIN 12 0 0 1 1 0 0 1 L0 PIN 11 0 1 0 1 0 1 0 1 1 1 APPLICATION DSX-1 (0 to 133 feet)/0dB CSU DSX-1 (133 to 266 feet) DSX-1 (266 to 399 feet) DSX-1 (399 to 533 feet) DSX-1 (533 to 655 feet) Reserved Reserved DSX-1 (0 to 133ft)/0dB CSU + enable transmit and receive gapped clock N.M. = not meaningful Note 1: Transformer turns ratio. Note 2: TTD pin must be connected high in this mode. 26 of 129 DS26504 T1/E1/J1/64KCC BITS Element 6.4 Receiver Operating Modes Table 6-5. Receive Path Operating Mode RMODE3 PIN 64 0 0 0 0 0 0 0 0 1 1 RMODE2 PIN 61 0 0 0 0 1 1 1 1 0 0 RMODE1 PIN 4 0 0 1 1 0 0 1 1 0 0 RMODE0 PIN 3 0 1 0 1 0 1 0 1 0 1 1 0 1 0 1 1 1 1 1 0 1 1 1 1 1 0 0 1 1 1 0 1 0 1 RECEIVE PATH OPERATING MODE T1 D4 Framing Mode T1 ESF Framing Mode J1 D4 Framing Mode J1 ESF Framing Mode E1 FAS Framing Mode E1 CAS Framing Mode E1 CRC4 Framing Mode E1 CAS and CRC4 Framing Mode E1 G.703 2048kHz Synchronization Interface Mode 64kHz + 8kHz Synchronization Interface Mode 64kHz + 8kHz + 400Hz Synchronization Interface Mode 6312kHz Synchronization Interface Mode GR378 64kHz Composite Clock G.703 Level B 64kHz + 8kHz Synchronization Interface Reserved Reserved 6.5 Transmitter Operating Modes Table 6-6.Transmit Path Operating Mode TMODE3 PIN 62 0 0 0 0 0 0 0 0 1 1 TMODE2 PIN 48 0 0 0 0 1 1 1 1 0 0 TMODE1 PIN 49 0 0 1 1 0 0 1 1 0 0 TMODE0 PIN 14 0 1 0 1 0 1 0 1 0 1 1 0 1 0 1 1 0 1 1 0 1 0 1 1 0 1 1 1 1 1 1 1 0 1 TRANSMIT PATH OPERATING MODE T1 D4 Framing Mode T1 ESF Framing Mode J1 D4 Framing Mode J1 ESF Framing Mode E1 FAS Framing Mode E1 CAS Framing Mode E1 CRC4 Framing Mode E1 CAS and CRC4 E1 G.703 2048 kHz Synchronization Interface Mode 64kHz + 8kHz Synchronization Interface Mode 64kHz + 8kHz + 400Hz Synchronization Interface Mode 6312kHz Synchronization Interface Mode GR378 64kHz Composite Clock G.703 Level B 64kHz + 8kHz Synchronization Interface Reserved Reserved 27 of 129 DS26504 T1/E1/J1/64KCC BITS Element 6.6 MCLK Pre-Scaler Table 6-7. MCLK Pre-Scaler for T1 Mode MPS1 PIN 16 0 0 1 1 0 0 1 1 MPS0 PIN 15 0 1 0 1 0 1 0 1 JACKS0 PIN 46 0 0 0 0 1 1 1 1 MCLK (MHz) 1.544 3.088 6.176 12.352 2.048 4.096 8.192 16.384 Table 6-8. MCLK Pre-Scaler for E1 Mode MPS1 PIN 16 0 0 1 1 MPS0 PIN 15 0 1 0 1 JACKS0 PIN 46 0 0 0 0 MCLK (MHz) 2.048 4.096 8.192 16.384 6.7 Payload Clock Output The TCLKO and RCLK pins can output a clock with the F-Bit (T1) or the TS0 and TS16 (E1) bit position gapped out. This function is only available in T1 or E1 mode. This is useful in basic transceiver applications where a payload or “demand” clock is needed. In Hardware Mode, the payload clock output is selected by the L0, L1, and L2 line build-out pins. In Hardware Mode, this function is only available in certain build-out modes. See the line build-out tables in Section 6.3 for selecting the payload clock mode. 28 of 129 DS26504 T1/E1/J1/64KCC BITS Element 6.8 Other Hardware Controller Mode Features Table 6-9. Other Operational Modes PIN RSM PIN 1 TSM PIN 2 RLB PIN 60 TAIS PIN 10 HBE PIN 55 DESCRIPTION RS_8K Mode Select: Selects frame or multiframe pulse at RS_8K pin. 0 = frame mode 1 = multiframe mode TS_8K_4 Mode Select: In T1 or E1 operation, selects frame or multiframe mode for the TS_8K_4 pin. 0 = frame mode 1 = multiframe mode Remote Loopback Enable: In this loopback, data input to the framer portion of the DS26504 will be transmitted back to the transmit portion of the LIU. Data will continue to pass through the receive side framer of the DS26504 as it would normally and the data from the transmit side formatter will be ignored. 0 = loopback disabled 1 = loopback enabled Transmit AIS. In T1, E1, and J1 modes, this pin transmits an unframed all-ones pattern. 0 = transmit AIS alarm 1 = normal transmission In any 64KCC mode, this pin transmits all ones without any sub-rate encoding (no BPVs). 0 = transmit all-ones pattern without BPVs (sub-rates) 1 = normal transmission Receive and Transmit HDB3/B8ZS Enable 0 = HDB3/B8ZS disabled 1 = HDB3/B8ZS enabled 29 of 129 DS26504 T1/E1/J1/64KCC BITS Element 7. PROCESSOR INTERFACE The DS26504 is controlled via a nonmultiplexed (BIS[1:0] = 01) or a multiplexed (BIS[1:0] = 00) parallel bus. There is also a serial bus mode option, as well as a hardware mode of operation. The bus interface type is selected by BIS1 and BIS0 as shown in Table 7-1. Table 7-1. Port Mode Select BIS1 0 0 1 1 BIS0 0 1 0 1 PORT MODE Parallel Port Mode (Multiplexed) Parallel Port Mode (Nonmultiplexed) Serial Port Mode (SPI) Hardware Mode 7.1 Parallel Port Functional Description In parallel mode, the DS26504 can operate with either Intel or Motorola bus timing configurations. If the BTS pin is tied low, Intel timing will be selected; if tied high, Motorola timing will be selected. All Motorola bus signals are listed in parentheses (). See the timing diagrams in the AC Electrical Characteristics section for more details. 7.2 SPI Serial Port Interface Functional Description A serial SPI bus interface is selected when the bus select is 10 (BIS[1:0] = 10). In this mode, a master/slave relationship is enabled on the serial port with three signal lines (SCK, MOSI, and MISO) and a chip select (CS), with the DS26504 acting as the slave. Port read/write timing is not related to the system read/write timing, thus allowing asynchronous, half-duplex operation. See the AC Electrical Characteristics section for the AC timing characteristics of the serial port. 7.2.1 Clock Phase and Polarity Clock Phase and Polarity are selected by the CPHA and CPOL pins. The slave device should always be configured to match the bus master. See the SPI Serial Port Mode section for detailed functional timing diagrams. 7.2.2 Bit Order The most significant bit (MSB) of each byte is transmitted first. 7.2.3 Control Byte The bus master will transmit two control bytes following a chip select to a slave device. The MSB will be a R/W bit (1 = read, 0 = write). The next 6 bits will be padded with zeros. The LSB of the first byte will be A[7]. The second control byte will be the address bits (A[6:0]) of the target register, followed by a Burst bit in the LSB position (1 = Burst, 0 = Nonburst). 7.2.4 Burst Mode The last bit of the second control byte (LSB) is the Burst Mode bit. When the Burst bit is enabled (set to 1) and a read operation is performed, the register address is automatically incremented after the LSB of the previous byte read to the next register address. Data will be available on the next clock edge following the LSB of the previous byte read. When the Burst bit is enabled (set to 1) and a write operation is performed, the register address will be automatically incremented to the next byte boundary following the LSB of the previous register write, and 8 more data bits will be expected on the serial bus. Burst accesses 30 of 129 DS26504 T1/E1/J1/64KCC BITS Element are terminated when CS is removed. If CS is removed before all 8 bits of the data are read, the remaining data will be lost. If CS is removed before all 8 bits of data are written to the part, no write access will occur and the target register will not be updated. Note: During a Burst-Read access, data must be fetched internally to the part as the LSB of the previous byte is transmitted out. If this pre-fetch read access occurs to a Clear-On-Read register or a FIFO register address, and the Burst access is terminated without reading this byte out of the port, the data will be lost and/or the register cleared. Users should not terminate their Burst Read accesses at the address byte proceeding a Clear-On-Read register or a FIFO register. Data loss could occur due to the internal prefetch operation performed by the interface. 7.2.5 Register Writes The register write sequence is shown in the functional timing diagrams in Section 18. After a CS, the bus master transmits a write control byte containing the R/W bit, the target register address, and the Burst bit. These two control bytes will be followed by the data byte to be written. After the first data byte, if the Burst bit is set, the DS26504 auto-increments its address counter and writes each byte received to the next higher address location. After writing address FFh, the address counter rolls over to 00h and continues to auto-increment. 7.2.6 Register Reads The register read sequence is shown in Section 18. After a CS, the bus master transmits a read control byte containing the R/W bit, the target register address, and the Burst bit. After these two control bytes, the DS26504 responds with the requested data byte. After the first data byte, if the Burst bit is set, the DS26504 auto-increments its address counter and transmits the byte stored in the next higher address location. Note the warning mentioned above, as data loss could potentially occur due to the data pre-fetch that is required to support this mode. After reading address FFh, the address counter rolls over to 00h and continues to auto-increment. 31 of 129 DS26504 T1/E1/J1/64KCC BITS Element 7.3 Register Map Table 7-2. Register Map Sorted By Address ADDRESS TYPE 00 01 02 03 04 05 06 07 08 09 0A 0B 0C 0D 0E 0F 10 11 12 13 14 15 16 17 18 19 1A 1B 1C 1D 1E 1F 20 21 22 23-2F 30 31 32 33 34 35-3F 40 41 R/W R/W R/W R/W R/W R/W R/W R/W R/W R/W R/W — — — — — R R R R R R/W R R/W R R/W R R/W R R/W R/W R/W R/W R R/W — R/W R/W R/W R/W R/W — R/W R/W REGISTER NAME Test Reset Register I/O Configuration Register 1 I/O Configuration Register 2 T1 Receive Control Register 1 T1 Receive Control Register 2 T1 Transmit Control Register 1 T1 Transmit Control Register 2 T1 Common Control Register Mode Configuration Register Transmit PLL Control Register 1 Transmit PLL Control Register 2 Reserved Reserved Reserved Reserved Reserved Device Identification Register Information Register 1 Information Register 2 Interrupt Information Register Status Register 1 Interrupt Mask Register 1 Status Register 2 Interrupt Mask Register 2 Status Register 3 Interrupt Mask Register 3 Status Register 4 Interrupt Mask Register 4 Information Register 3 E1 Receive Control Register E1 Transmit Control Register BOC Control Register Loopback Control Register Status Register 5 Internal Mask Register 5 Reserved Line Interface Control 1 Line Interface Control 2 Line Interface Control 3 Line Interface Control 4 Transmit Line Build-Out Control Reserved Transmit Align Frame Register Transmit Non-Align Frame Register 32 of 129 REGISTER ABBREVIATION TSTRREG IOCR1 IOCR2 T1RCR1 T1RCR2 T1TCR1 T1TCR2 T1CCR MCREG TPCR1 — (Note 1) (Note 1) (Note 1) (Note 1) (Note 1) IDR INFO1 INFO2 IIR SR1 IMR1 SR2 IMR2 SR3 IMR3 SR4 IMR4 INFO3 E1RCR E1TCR BOCC LBCR SR5 IMR5 (Note 1) LIC1 LIC2 LIC3 LIC4 TLBC (Note 1) TAF TNAF DS26504 T1/E1/J1/64KCC BITS Element ADDRESS TYPE 42 43 44 45 46 47 48 49 4A 4B-4F 50 51 52 53 54-55 56 57 58 59 5A 5B 5C 5D 5E 5F 60-EF F0 F1 F2 F3 F4 F5 F6 F7 F8 F9 FA FB FC FD FE FF R/W R/W R/W R/W R/W R/W R/W R/W R/W — R R/W R/W R/W — R R R R R R R R R R — R/W R/W R/W R/W R/W R/W R/W R/W R/W R/W R/W R/W R/W R/W R/W R/W REGISTER NAME Transmit Si Align Frame Transmit Si Non-Align Frame Transmit Remote Alarm Bits Transmit Sa4 Bits Transmit Sa5 Bits Transmit Sa6 Bits Transmit Sa7 Bits Transmit Sa8 Bits Transmit Sa Bit Control Register Reserved Receive FDL Register Transmit FDL Register Receive Facility Data Link Match Register 1 Receive Facility Data Link Match Register 2 Reserved Receive Align Frame Register Receive Non-Align Frame Register Receive Si Align Frame Receive Si Non-Align Frame Receive Remote Alarm Bits Receive Sa4 Bits Receive Sa5 Bits Receive Sa6 Bits Receive Sa7 Bits Receive Sa8 Bits Reserved Test Register 1 Test Register 2 Test Register 3 Test Register 4 Test Register 5 Test Register 6 Test Register 7 Test Register 8 Test Register 9 Test Register 10 Test Register 11 Test Register 12 Test Register 13 Test Register 14 Test Register 15 Test Register 16 Note 1: Register reserved for future use and must remain = 0. Note 2: TEST1 to TEST16 registers are used only by the factory and must remain = 0. 33 of 129 REGISTER ABBREVIATION TsiAF TSiNAF TRA Tsa4 Tsa5 Tsa6 Tsa7 Tsa8 TSACR (Note 1) RFDL TFDL RFDLM1 RFDLM2 (Note 1) RAF RNAF RsiAF RSiNAF RRA Rsa4 Rsa5 Rsa6 Rsa7 Rsa8 (Note 1) TEST1 (Note 2) TEST2 (Note 2) TEST3 (Note 2) TEST4 (Note 2) TEST5 (Note 2) TEST6 (Note 2) TEST7 (Note 2) TEST8 (Note 2) TEST9 (Note 2) TEST10 (Note 2) TEST11 (Note 2) TEST12 (Note 2) TEST13 (Note 2) TEST14 (Note 2) TEST15 (Note 2) TEST16 (Note 2) DS26504 T1/E1/J1/64KCC BITS Element 7.3.1 Power-Up Sequence The DS26504 contains an on-chip power-up reset function that automatically clears the writeable register space immediately after power is supplied to the device. The user can issue a chip reset at any time. Issuing a reset will disrupt signals flowing through the DS26504 until the device is reprogrammed. The reset can be issued through hardware using the TSTRST pin or through software using the SFTRST function in the master mode register. The LIRST (LIC2.6) should be toggled from zero to one to reset the line interface circuitry. (It will take the DS26504 about 40ms to recover from the LIRST bit being toggled.) 7.3.2 Test Reset Register Register Name: Register Description: Register Address: TSTRREG Test Reset Register 00h Bit # Name Default HW Mode 7 — 0 6 — 0 5 TEST1 0 4 TEST0 0 3 — 0 2 — 0 1 — 0 0 SFTRST 0 X X X X X X X X Bit 0: Software-Issued Reset (SFTRST). A zero-to-one transition causes the register space in the DS26504 to be cleared. A reset clears all configuration and status registers. The bit automatically clears itself when the reset has completed. Bits 1, 2, 3, 6, 7: Unused, must be set = 0 for proper operation. Bits 4 and 5: Test Mode Bits (TEST0 and TEST1). Test modes are used to force the output pins of the DS26504 into known states. This can facilitate the checkout of assemblies during the manufacturing process and also be used to isolate devices from shared buses. TEST1 0 0 1 1 TEST0 0 1 0 1 EFFECT ON OUTPUT PINS Operate normally Force all output pins into three-state (including all I/O pins and parallel port pins) Force all output pins low (including all I/O pins except parallel port pins) Force all output pins high (including all I/O pins except parallel port pins) 34 of 129 DS26504 T1/E1/J1/64KCC BITS Element 7.3.3 Mode Configuration Register Register Name: Register Description: Register Address: Bit # Name Default HW Mode 7 TMODE3 0 TMODE3 PIN 62 MCREG Mode Configuration Register 08h 6 TMODE2 0 TMODE2 PIN 48 5 TMODE1 0 TMODE1 PIN 49 4 TMODE0 0 TMODE0 PIN 14 3 RMODE3 0 RMODE3 PIN 64 2 RMODE2 0 RMODE2 PIN 61 1 RMODE1 0 RMODE1 PIN 4 0 RMODE0 0 RMODE0 PIN 3 Bits 0 to 3: Receive Mode Configuration (RMODE[0:3]). Used to select the operating mode of the receive path for the DS26504. RMODE3 0 0 0 0 0 0 0 0 1 1 1 1 1 1 1 1 RMODE2 0 0 0 0 1 1 1 1 0 0 0 0 1 1 1 1 RMODE1 0 0 1 1 0 0 1 1 0 0 1 1 0 0 1 1 RMODE0 0 1 0 1 0 1 0 1 0 1 0 1 0 1 0 1 RECEIVE PATH OPERATING MODE T1 D4 Framing Mode T1 ESF Framing Mode J1 D4 Framing Mode J1 ESF Framing Mode E1 FAS Framing Mode E1 CAS Framing Mode E1 CRC4 Framing Mode E1 CAS and CRC4 Framing Mode E1 G.703 2048 kHz Synchronization Interface Mode 64kHz + 8kHz Synchronization Interface Mode 64kHz + 8kHz + 400Hz Synchronization Interface Mode 6312kHz Synchronization Interface Mode GR378 64kHz Composite Clock G.703 Level B 64kHz + 8kHz Synchronization Interface Reserved Reserved Bits 4 to 7: Transmit Mode Configuration (TMODE[4:7]). Used to select the operating mode of the transmit path for the DS26504. TMODE3 0 TMODE2 0 TMODE1 0 TMODE0 0 0 0 0 1 0 0 0 0 0 0 1 1 1 1 1 1 1 1 0 0 1 1 1 1 0 0 0 0 1 1 1 1 1 1 0 0 1 1 0 0 1 1 0 0 1 1 0 1 0 1 0 1 0 1 0 1 0 1 0 1 TRANSMIT PATH OPERATING MODE T1 D4 Framing Mode T1 ESF Framing Mode (Note: In this mode, the TFSE (T1TCR2.6) bit should be set = 0.) J1 D4 Framing Mode J1 ESF Framing Mode E1 FAS Framing Mode E1 CAS Framing Mode E1 CRC4 Framing Mode E1 CAS and CRC4 E1 G.703 2048 kHz Synchronization Interface Mode 64kHz + 8kHz Synchronization Interface Mode 64kHz + 8kHz + 400Hz Synchronization Interface Mode 6312kHz Synchronization Interface Mode GR378 64kHz Composite Clock G.703 Level B 64kHz + 8kHz Synchronization Interface Reserved Reserved 35 of 129 DS26504 T1/E1/J1/64KCC BITS Element Register Name: Register Description: Register Address: Bit # Name Default HW Mode TPCR1 Transmit PLL Control Register 1 09h 7 TPLLOFS1 0 6 TPLLOFS0 0 5 PLLOS 0 4 TPLLIFS1 0 3 TPLLIFS0 0 2 TPLLSS 0 0 0 0 0 0 0 1 TCSS1 0 TCSS1 PIN 31 0 TCSS0 0 TCSS0 PIN 63 For more information on all the bits in the Transmit PLL control register, refer to Figure 3-3. Bits 0 and 1: Transmit Clock (TX CLOCK) Source Select (TCSS[0:1]). These bits control the output of the TX PLL Clock Mux function. See Figure 3-3. TCSS1 TCSS0 0 0 1 1 0 1 0 1 TRANSMIT CLOCK (TX CLOCK) SOURCE (See Figure 3-3) The TCLK pin is the source of transmit clock. The PLL_CLK is the source of transmit clock. The scaled signal present at MCLK as the transmit clock. The signal present at RCLK is the transmit clock. Bit 2: Transmit PLL_CLK Source Select (TPLLSS). Selects the reference signal for the TX PLL. 0 = Use the recovered network clock. This is the same clock available at the RCLK pin (output). 1 = Use the externally provided clock present at the TCLK pin. Bit 3 and 4: Transmit PLL Input Frequency Select (TPLLIFS[0:1]). These bits, along with TPLLIFS2 (TPCR2.0), are used to indicate the reference frequency being input to the TX PLL. TPLLIFS2 (TPCR2.0) 0 0 0 0 1 1 TPLLIFS1 TPLLIFS0 0 0 1 1 0 0 0 1 0 1 0 1 TX PLL INPUT FREQUENCY 1.544MHz 2.048MHz 64kHz 6312kHz 8kHz 19.44MHz Bit 5: PLL_OUT Select (PLLOS). This bit selects the source for the PLL_OUT pin. See Figure 3-3. 0 = PLL_OUT is sourced directly from the TX PLL. 1 = PLL_OUT is the output of the TX PLL mux. Bits 6 and 7: Transmit PLL Output Frequency Select (TPLLOFS[0:1]). These bits, along with TPLLOFS1 (TPCR2.1), are used to select the TX PLL output frequency. TPLLOFS2 (TPCR2.1) 0 0 0 0 1 1 TPLLOFS1 TPLLOFS0 0 0 1 1 0 0 0 1 0 1 0 1 TX PLL OUTPUT FREQUENCY 1.544MHz 2.048MHz 64kHz 6312kHz 8kHz 19.44MHz 36 of 129 DS26504 T1/E1/J1/64KCC BITS Element Register Name: TPCR2 Register Description: Register Address: Transmit PLL Control Register 2 0Ah Bit # Name Default 7 — 6 — 5 — 4 — 3 — 2 — 1 TPLLOFS2 0 0 TPLLIFS2 0 Bit 0: Transmit Clock Source Select (TPLLOFS2). This bit, along with TPLLOFS0 (TPCR1.7) and TPLLOFS1 (TPCR1.6), is used to indicate the reference frequency being input to the TX PLL. See the table in TPCR1 register description. Bit 1: Transmit Clock Source Select (TPLLIFS2). This bit, along with TPLLIFS0 (TPCR1.4) and TPLLIFS1 (TPCR1.3), is used to the frequency being output from the TX PLL. See the table in TPCR1 register description. Bits 2 to 7: Unused 7.4 Interrupt Handling Various alarms, conditions, and events in the DS26504 can cause interrupts. For simplicity, these are all referred to as events in this explanation. All STATUS registers can be programmed to produce interrupts. Each status register has an associated interrupt mask register. For example, SR1 (Status Register 1) has an interrupt control register called IMR1 (Interrupt Mask Register 1). Status registers are the only sources of interrupts in the DS26504. On power-up, all writeable registers are automatically cleared. Because bits in the IMRx registers must be set = 1 to allow a particular event to cause an interrupt, no interrupts can occur until the host selects which events are to product interrupts. As there are potentially many sources of interrupts on the DS26504, several features are available to help sort out and identify which event is causing an interrupt. When an interrupt occurs, the host should first read the IIR register (interrupt information register) to identify which status register(s) is producing the interrupt. Once that is determined, the individual status register or registers can be examined to determine the exact source. Once an interrupt has occurred, the interrupt handler routine should clear the IMRx registers to stop further activity on the interrupt pin. After all interrupts have been determined and processed, the interrupt hander routine should restore the state of the IMRx registers. 7.5 Status Registers When a particular event or condition has occurred (or is still occurring in the case of conditions), the appropriate bit in a status register will be set to a one. All the status registers operate in a latched fashion, which means that if an event or condition occurs, a bit is set to a one. It remains set until the user reads that bit. An event bit is cleared when it is read and it is not set again until the event has occurred again. Condition bits such as RLOS remain set if the alarm is still present. The user always precedes a read of any of the status registers with a write. The byte written to the register informs the DS26504 which bits the user wishes to read and have cleared. The user writes a byte to one of these registers, with a one in the bit positions he or she wishes to read, and a zero in the bit positions he or she does not wish to obtain the latest information on. When a one is written to a bit location, the read register is updated with the latest information. When a zero is written to a bit position, the read register is not updated and the previous value is held. A write to the status registers is immediately followed by a read of the same register. This write-read scheme allows an external microcontroller or microprocessor to 37 of 129 DS26504 T1/E1/J1/64KCC BITS Element individually poll certain bits without disturbing the other bits in the register. This operation is key in controlling the DS26504 with higher-order languages. Status register bits are divided into two groups: condition bits and event bits. Condition bits are typically network conditions such as loss of frame or all-ones detect. Event bits are typically markers such as the one-second timer. Each status register bit is labeled as a condition or event bit. Some of the status registers have bits for both the detection of a condition and the clearance of the condition. For example, SR2 has a bit that is set when the device goes into a loss-of-frame state (SR2.0, a condition bit) and a bit that is set (SR2.4, an event bit) when the loss-of-frame condition clears (goes in sync). Some of the status register bits (condition bits) do not have a separate bit for the “condition clear” event but rather the status bit can produce interrupts on both edges, setting, and clearing. These bits are marked as “double interrupt bits.” An interrupt is produced when the condition occurs and when it clears. 7.6 Information Registers Information registers operate the same as status registers except they cannot cause interrupts. INFO3 register is a read-only register and it reports the status of the E1 synchronizer in real time. INFO3 information bits are not latched, and it is not necessary to precede a read of these bits with a write. 38 of 129 DS26504 T1/E1/J1/64KCC BITS Element 7.7 Interrupt Information Registers The Interrupt Information Registers (IIRs) provide an indication of which Status Registers (SR1 to SR4) are generating an interrupt. When an interrupt occurs, the host can read IIR to quickly identify which of the four status registers are causing the interrupt. Register Name: Register Description: Register Address: IIR Interrupt Information Register 13h Bit # Name Default HW Mode 7 — 0 6 — 0 5 — 0 4 SR5 0 3 SR4 0 2 SR3 0 1 SR2 0 0 SR1 0 X X X X X X X X Bit 0: Status Register 1 (SR1) 0 = Status Register 1 interrupt not active. 1 = Status Register 1 interrupt active. Bit 1: Status Register 2 (SR2) 0 = Status Register 2 interrupt not active. 1 = Status Register 2 interrupt active. Bit 2: Status Register 3 (SR3) 0 = Status Register 3 interrupt not active. 1 = Status Register 3 interrupt active. Bit 3: Status Register 4 (SR4) 0 = Status Register 4 interrupt not active. 1 = Status Register 4 interrupt active. Bit 4: Status Register 5 (SR5) 0 = Status Register 5 interrupt not active. 1 = Status Register 5 interrupt active. Bits 5 to 7: Unused 39 of 129 DS26504 T1/E1/J1/64KCC BITS Element 8. T1 FRAMER/FORMATTER CONTROL REGISTERS The T1 framer portion of the DS26504 is configured via a set of five control registers. Typically, the control registers are only accessed when the system is first powered up. Once the DS26504 has been initialized, the control registers only need to be accessed when there is a change in the system configuration. There are two receive control registers (T1RCR1 and T1RCR2), two transmit control registers (T1TCR1 and T1TCR2), and a common control register (T1CCR). Each of these registers is described in this section. 8.1 T1 Control Registers Register Name: Register Description: Register Address: Bit # Name Default HW Mode T1RCR1 T1 Receive Control Register 1 03h 7 — 0 6 ARC 0 5 OOF1 0 4 OOF2 0 3 SYNCC 0 2 SYNCT 0 1 SYNCE 0 0 RESYNC 0 0 0 0 0 0 0 0 0 Bit 0: Resynchronize (RESYNC). When toggled from low to high, a resynchronization of the receive side framer is initiated. Must be cleared and set again for a subsequent resync. Bit 1: Sync Enable (SYNCE) 0 = auto resync enabled 1 = auto resync disabled Bit 2: Sync Time (SYNCT) 0 = qualify 10 bits 1 = qualify 24 bits Bit 3: Sync Criterion (SYNCC) In D4 Framing Mode: 0 = search for Ft pattern, then search for Fs pattern 1 = cross-couple Ft and Fs pattern In ESF Framing Mode: 0 = search for FPS pattern only 1 = search for FPS and verify with CRC6 Bits 4 and 5: Out-of-Frame Select Bits (OOF2, OOF1) OOF2 OOF1 0 0 1 1 0 1 0 1 OUT-OF-FRAME CRITERION 2/4 frame bits in error 2/5 frame bits in error 2/6 frame bits in error 2/6 frame bits in error Bit 6: Auto Resync Criterion (ARC) 0 = resync on OOF or RLOS event 1 = resync on OOF only Bit 7: Unused, must be set = 0 for proper operation. 40 of 129 DS26504 T1/E1/J1/64KCC BITS Element Register Name: Register Description: Register Address: T1RCR2 T1 Receive Control Register 2 04h Bit # Name Default HW Mode 7 — 0 6 — 0 0 0 5 RB8ZS 0 HBE PIN 55 4 — 0 3 — 0 2 — 0 1 RJC 0 0 RD4YM 0 0 0 0 0 0 Bit 0: Receive Side D4 Yellow Alarm Select (RD4YM) 0 = zeros in bit 2 of all channels 1 = a one in the S-bit position of frame 12 (J1 Yellow Alarm Mode) Bit 1: Receive Japanese CRC6 Enable (RJC) 0 = use ANSI/AT&T/ITU CRC6 calculation (normal operation) 1 = use Japanese standard JT–G704 CRC6 calculation Bits 2, 3, 4, 6, 7: Unused, must be set = 0 for proper operation. Bit 5: Receive B8ZS Enable (RB8ZS) 0 = B8ZS disabled 1 = B8ZS enabled 41 of 129 DS26504 T1/E1/J1/64KCC BITS Element Register Name: Register Description: Register Address: Bit # Name Default HW Mode 7 TJC 0 RMODEx PINS T1TCR1 T1 Transmit Control Register 1 05h 6 TFPT 0 5 TCPT 0 4 — 0 3 — 0 2 — 0 1 — 0 0 TYEL 0 0 0 0 0 0 0 0 Bit 0:Transmit Yellow Alarm (TYEL) 0 = do not transmit yellow alarm 1 = transmit yellow alarm Bits 1 to 4: Unused, must be set = 0 for proper operation. Bit 5: Transmit CRC Pass-Through (TCPT) 0 = source CRC6 bits internally 1 = CRC6 bits sampled at TSER during F-bit time Bit 6: Transmit F-Bit Pass-Through (TFPT) 0 = F bits sourced internally 1 = F bits sampled at TSER Bit 7: Transmit Japanese CRC6 Enable (TJC) 0 = use ANSI/AT&T/ITU CRC6 calculation (normal operation) 1 = use Japanese standard JT–G704 CRC6 calculation 42 of 129 DS26504 T1/E1/J1/64KCC BITS Element Register Name: Register Description: Register Address: Bit # Name Default HW Mode 7 TB8ZS 0 HBE PIN 55 T1TCR2 T1 Transmit Control Register 2 06h 6 TFSE 1 5 — 0 4 FBCT2 0 3 FBCT1 0 2 TD4YM 0 1 — 0 0 TB7ZS 0 1 0 0 0 0 0 0 Bit 0: Transmit-Side Bit 7 Zero-Suppression Enable (TB7ZS) 0 = no stuffing occurs 1 = bit 7 forced to a 1 in channels with all 0s Bits 1 and 5: Unused, must be set = 0 for proper operation. Bit 2: Transmit-Side D4 Yellow Alarm Select (TD4YM) 0 = 0s in bit 2 of all channels 1 = a 1 in the S-bit position of frame 12 Bit 3: F-Bit Corruption Type 1 (FBCT1). A low-to-high transition of this bit causes the next three consecutive Ft (D4 framing mode) or FPS (ESF framing mode) bits to be corrupted causing the remote end to experience a loss of frame (loss of synchronization). Bit 4: F-Bit Corruption Type 2 (FBCT2). Setting this bit high enables the corruption of one Ft (D4 framing mode) or FPS (ESF framing mode) bit in every 128 Ft or FPS bits as long as the bit remains set. Bit 6: Transmit Fs-Bit Insertion Enable (TFSE). Only set this bit to a 1 in D4 framing applications. Must be set to 1 to source the Fs pattern from the TFDL register. In all other modes this bit must be set = 0. 0 = Fs-bit insertion disabled 1 = Fs-bit insertion enabled Bit 7: Transmit B8ZS Enable (TB8ZS) 0 = B8ZS disabled 1 = B8ZS enabled 43 of 129 DS26504 T1/E1/J1/64KCC BITS Element Register Name: Register Description: Register Address: Bit # Name Default HW Mode T1CCR T1 Common Control Register 07h 7 — 0 6 — 0 5 — 0 4 TRAI-CI 0 3 TAIS-CI 0 2 — 0 1 PDE 0 0 — 0 0 0 0 0 0 0 0 0 Bits 0, 2, 5, 6, 7: Unused, must be set = 0 for proper operation. Bit 1: Pulse-Density Enforcer Enable (PDE). The framer always examines the transmit and receive data streams for violations of these, which are required by ANSI T1.403. No more than 15 consecutive zeros and at least N ones in each and every time window of 8 x (N + 1) bits, where N = 1 through 23. When this bit is set to one, the DS26504 forces the transmitted stream to meet this requirement no matter the content of the transmitted stream. When running B8ZS, this bit should be set to zero, as B8ZS encoded data streams cannot violate the pulse-density requirements. 0 = disable transmit pulse-density enforcer 1 = enable transmit pulse-density enforcer Bit 3: Transmit AIS-CI Enable (TAIS-CI). Setting this bit causes the AIS-CI code to be transmitted from the framer to the LIU, as defined in ANSI T1.403. 0 = do not transmit the AIS-CI code 1 = transmit the AIS-CI code Bit 4: Transmit RAI-CI Enable (TRAI-CI). Setting this bit causes the ESF RAI-CI code to be transmitted in the FDL bit position. 0 = do not transmit the ESF RAI-CI code 1 = transmit the ESF RAI-CI code 44 of 129 DS26504 T1/E1/J1/64KCC BITS Element Table 8-1. T1 Alarm Criterion ALARM SET CRITERION CLEAR CRITERION Blue Alarm (AIS) (Note 1) Over a 3ms window, five or fewer zeros are received Over a 3ms window, six or more zeros are received D4 Yellow Alarm (RAI) (T1RCR2.0 = 0) Bit 2 of 256 consecutive channels is set to zero for at least 254 occurrences Bit 2 of 256 consecutive channels is set to zero for less than 254 occurrences Japanese Yellow Alarm (T1RCR2.0 = 1) 12th framing bit is set to one for two consecutive occurrences 12th framing bit is set to zero for two consecutive occurrences ESF Yellow Alarm (RAI) 16 consecutive patterns of 00FF appear in the FDL 14 or fewer patterns of 00FF hex out of 16 possible appear in the FDL Red Alarm (RLOS) (Also known as Loss of Signal) 192 consecutive zeros are received 14 or more ones out of 112 possible bit positions are received, starting with the first one received Note 1: The definition of Blue Alarm (or Alarm Indication Signal) is an unframed, all-ones signal. Blue Alarm detectors should be able to operate properly in the presence of a 10E-3 error rate, and they should not falsely trigger on a framed, all-ones signal. The Blue Alarm criterion in the DS26504 has been set to achieve this performance. 45 of 129 DS26504 T1/E1/J1/64KCC BITS Element 9. E1 FRAMER/FORMATTER CONTROL REGISTERS The E1 framer portion of the DS26504 is configured via a set of two control registers. Typically, the control registers are only accessed when the system is first powered up. Once the DS26504 has been initialized, the control registers only need to be accessed when there is a change in the system configuration. There is one receive control register (E1RCR) and one transmit control register (E1TCR). There are also two information registers and a status register, as well as an interrupt mask register. Each of these registers is described in this section. 9.1 E1 Control Registers Register Name: Register Description: Register Address: Bit # Name Default HW Mode E1RCR E1 Receive Control Register 1Dh 7 — 0 6 RLOSA 0 0 0 5 RHDB3 0 HBE PIN 55 4 — 0 3 — 0 2 FRC 0 1 SYNCE 0 0 RESYNC 0 0 0 0 0 0 Bit 0: Resync (RESYNC). When toggled from low to high, a resync is initiated. Must be cleared and set again for a subsequent resync. Bit 1: Sync Enable (SYNCE) 0 = auto resync enabled 1 = auto resync disabled Bit 2: Frame Resync Criterion (FRC) 0 = resync if FAS received in error three consecutive times 1 = resync if FAS or bit 2 of non-FAS is received in error three consecutive times Bits 3, 4, 7: Unused, must be set = 0 for proper operation. Bit 5: Receive HDB3 Enable (RHDB3) 0 = HDB3 disabled 1 = HDB3 enabled Bit 6: Receive Loss-of-Signal Alternate Criterion (RLOSA). Defines the criterion for a Receive Loss-of-Signal condition. 0 = RLOS declared upon 255 consecutive zeros (125µs) 1 = RLOS declared upon 2048 consecutive zeros (1ms) 46 of 129 DS26504 T1/E1/J1/64KCC BITS Element Table 9-1. E1 Sync/Resync Criterion FRAME OR MULTIFRAME LEVEL FAS CRC4 CAS SYNC CRITERION RESYNC CRITERION FAS present in frame N and N + 2, and FAS not present in frame N + 1 Two valid MF alignment words found within 8ms Valid MF alignment word found and previous time slot 16 contains code other than all zeros Three consecutive incorrect FAS received Alternate: (E1RCR.2 = 1) The above criterion is met or three consecutive incorrect bit 2 of non-FAS received 915 or more CRC4 code words out of 1000 received in error Two consecutive MF alignment words received in error 47 of 129 ITU SPEC. G.706 4.1.1 4.1.2 G.706 4.2 and 4.3.2 G.732 5.2 DS26504 T1/E1/J1/64KCC BITS Element Register Name: Register Description: Register Address: E1TCR E1 Transmit Control Register 1Eh Bit # Name Default HW Mode 7 TFPT 0 6 — 0 5 ARA 0 4 TsiS 0 3 AEBE 0 2 TUA1 0 0 0 0 0 0 0 1 THDB3 0 HBE PIN 55 0 AAIS 0 Bit 0: Automatic AIS Generation (AAIS) 0 = disabled 1 = enabled Bit 1: Transmit HDB3 Enable (THDB3) 0 = HDB3 disabled 1 = HDB3 enabled Bit 2: Transmit Unframed All Ones (TUA1) 0 = transmit data normally 1 = transmit an unframed all-ones code to LIU Bit 3: Automatic E-Bit Enable (AEBE) 0 = E bits not automatically set in the transmit direction 1 = E bits automatically set in the transmit direction Bit 4: Transmit International Bit Select (TsiS) 0 = sample Si bits at TSER pin 1 = source Si bits from TAF and TNAF registers (in this mode, E1TCR1.7 must be set to 0) Bit 5: Automatic Remote Alarm Generation (ARA) 0 = disabled 1 = enabled Bit 6:Unused, must be set = 0 for proper operation. Bit 7: Transmit Time Slot 0 Pass-Through (TFPT) 0 = FAS bits/Sa bits/remote alarm sourced internally from the TAF and TNAF registers 1 = FAS bits/Sa bits/remote alarm sourced from TSER 48 of 129 0 DS26504 T1/E1/J1/64KCC BITS Element 9.2 E1 Information Registers Register Name: Register Description: Register Address: INFO2 Information Register 2 12h Bit # Name Default HW Mode 7 — 0 6 — 0 5 — 0 4 — 0 3 — 0 2 CRCRC 0 1 FASRC 0 0 CASRC 0 X X X X X X X X Bit 0: CAS Resync Criterion Met Event (CASRC). Set when two consecutive CAS MF alignment words are received in error. Bit 1: FAS Resync Criterion Met Event (FASRC). Set when three consecutive FAS words are received in error. Bit 2: CRC Resync Criterion Met Event (CRCRC). Set when 915/1000 codewords are received in error. Bits 3 to 7: Unused Register Name: Register Description: Register Address: Bit # Name Default HW Mode INFO3 Information Register 3 (Real Time) 1Ch 7 CSC5 0 6 CSC4 0 5 CSC3 0 4 CSC2 0 3 CSC0 0 2 FASSA 0 1 CASSA 0 0 CRC4SA 0 X X X X X X X X Bit 0: CRC4 MF Sync Active (CRC4SA). Set while the synchronizer is searching for the CRC4 MF alignment word. Bit 1: CAS MF Sync Active (CASSA). Set while the synchronizer is searching for the CAS MF alignment word. Bit 2: FAS Sync Active (FASSA). Set while the synchronizer is searching for alignment at the FAS level. Bits 3 to 7: CRC4 Sync Counter Bits (CSC0, CSC2 to CSC5). The CRC4 sync counter increments each time the 8ms-CRC4 multiframe search times out. The counter is cleared when the framer has successfully obtained synchronization at the CRC4 level. The counter can also be cleared by disabling CRC4 mode. This counter is useful for determining the amount of time the framer has been searching for synchronization at the CRC4 level. ITU G.706 suggests that if synchronization at the CRC4 level cannot be obtained within 400ms, then the search should be abandoned and proper action taken. The CRC4 sync counter will roll over. CSC0 is the LSB of the 6-bit counter. (Note: The second LSB, CSC1, is not accessible. CSC1 is omitted to allow resolution to >400ms using 5 bits.) 49 of 129 DS26504 T1/E1/J1/64KCC BITS Element Table 9-2. E1 Alarm Criterion ALARM SET CRITERION RLOF An RLOF condition exists on power-up prior to initial synchronization, when a resync criterion has been met, or when a manual resync has been initiated via E1RCR.0 255 or 2048 consecutive zeros received as determined by E1RCR.0 Bit 3 of non-align frame set to one for three consecutive occasions RLOS RRA RUA1 RDMA V52LNK Fewer than three zeros in two frames (512 bits) Bit 6 of time slot 16 in frame 0 has been set for two consecutive multiframes Two out of three Sa7 bits are zero Register Name: Register Description: Register Address: Bit # Name Default HW Mode ITU SPEC. — CLEAR CRITERION — In 255-bit times, at least 32 ones are received Bit 3 of non-align frame set to zero for three consecutive occasions More than two zeros in two frames (512 bits) — G.775/G.962 O.162 2.1.4 O.162 1.6.1.2 — G.965 IDR Device Identification Register 10h 7 ID7 0 6 ID6 0 5 ID5 0 4 ID4 0 3 ID3 N 2 ID2 N 1 ID1 N 0 ID0 N X X X X X X X X Bits 0 to 3: Chip Revision Bits (ID0 to ID3). The lower four bits of the IDR are used to display the die revision of the chip. ID0 is the LSB of a decimal code that represents the chip revision. Bits 4 to 7: Device ID (ID4 to ID7). The upper four bits of the IDR are used to display the DS26504 ID. The DS26504 ID is 0010. DS26502 = 0000 DS26503 = 0001 DS26504 = 0010 50 of 129 DS26504 T1/E1/J1/64KCC BITS Element Register Name: Register Description: Register Address: Bit # Name Default HW Mode SR2 Status Register 2 16h 7 RYELC 0 6 RAISC 0 5 RLOSC 0 4 RLOFC 0 3 RYEL 0 X X X X X 2 RAIS 0 RAIS PIN 29 1 RLOS 0 RLOS PIN 32 0 RLOF 0 LOF PIN 30 Bit 0: Receive Loss-of-Frame Condition (RLOF). Set when the DS26504 is not synchronized to the received data stream. Bit 1: Receive Loss-of-Signal Condition (RLOS). Set when 255 (or 2048 if E1RCR.6 = 1) E1 mode or 192 T1 mode consecutive zeros have been detected. In 6312kHz Synchronization Interface Mode, this bit will be set when the signal received is out of range as defined by the G.703 Appendix II specification. Bit 2: Receive Alarm Indication Signal (T1= Blue Alarm, E1= AIS) Condition (RAIS). Set when an unframed all-ones code is received. Bit 3: Receive Yellow Alarm Condition (RYEL) (T1 only). Set when a yellow alarm is received. Bit 4: Receive Loss-of-Frame Clear Event (RLOFC). Set when the framer achieves synchronization; will remain set until read. Bit 5: Receive Loss-of-Signal Clear Event (RLOSC). Set when loss-of-signal condition is no longer detected. Bit 6: Receive Alarm Indication Signal Clear Event (RAISC). Set when the unframed all-ones condition is no longer detected. Bit 7: Receive Yellow Alarm Clear Event (RYELC) (T1 only). Set when the yellow alarm condition is no longer detected. 51 of 129 DS26504 T1/E1/J1/64KCC BITS Element Register Name: Register Description: Register Address: Bit # Name Default HW Mode IMR2 Interrupt Mask Register 2 17h 7 RYELC 0 6 RAISC 0 5 RLOSC 0 4 RLOFC 0 3 RYEL 0 2 RAIS 0 1 RLOS 0 0 RLOF 0 X X X X X X X X Bit 0: Receive Loss-of-Frame Condition (RLOF) 0 = interrupt masked 1 = interrupt enabled–interrupts on rising edge only Bit 1: Receive Loss-of-Signal Condition (RLOS) 0 = interrupt masked 1 = interrupt enabled–interrupts on rising edge only Bit 2: Receive Alarm Indication Signal Condition (RAIS) 0 = interrupt masked 1 = interrupt enabled–interrupts on rising edge only Bit 3: Receive Yellow Alarm Condition (RYEL) 0 = interrupt masked 1 = interrupt enabled–interrupts on rising edge only Bit 4: Receive Loss-of-Frame Clear Event (RLOFC) 0 = interrupt masked 1 = interrupt enabled Bit 5: Receive Loss-of-Signal Condition Clear (RLOSC) 0 = interrupt masked 1 = interrupt enabled Bit 6: Receive Alarm Indication Signal Clear Event (RAISC) 0 = interrupt masked 1 = interrupt enabled Bit 7: Receive Yellow Alarm Clear Event (RYELC) 0 = interrupt masked 1 = interrupt enabled 52 of 129 DS26504 T1/E1/J1/64KCC BITS Element 10. I/O PIN CONFIGURATION OPTIONS Register Name: Register Description: Register Address: IOCR1 I/O Configuration Register 1 01h Bit # Name Default HW Mode 7 G703TE 0 6 RSMS2 0 0 0 5 RSMS1 0 RSM PIN 1 4 RLOFF 0 CSM_TSDW 3 0 0 0 2 TSM 0 TSM PIN 2 1 TSIO 0 0 ODF 0 0 0 Bit 0: Output Data Format (ODF) 0 = bipolar data at TPOS and TNEG 1 = NRZ data at TPOS; TNEG = 0 Bit 1: TS_8K_4 I/O Select (TSIO). This bit determines whether the TS_8K_4 pin is an input or and output. See Table 10-1. 0 = TS_8K_4 is an input 1 = TS_8K_4 is an output Bit 2: TS_8K_4 Mode Select (TSM). In T1 or E1 operation, selects frame or multiframe mode for the TS_8K_4 pin. In 6312kHz or 64KCC mode, this bit should be set = 0. See Table 10-1. 0 = frame mode 1 = multiframe mode Bit 3: Composite Clock Sync Mode_Transmit Signaling Double-Wide Sync (CSM_TSDW). In 64kHz Composite Clock mode, this bit determines whether the TS_8K_4 pin is an 8kHz or a 400Hz reference input (TS_8K_4 pin in input mode, IOCR1 = 0), or an 8kHz or 400Hz reference output (TS_8K_4 pin in output mode, IOCR1 = 1). In T1 mode, setting this bit = 1 and setting TSIO = 1 will cause the sync pulse output on TS_8K_4 to be two clocks wide during signaling frames. In E1 or 6312kHz mode, this bit should be set = 0. See Table 10-1. 0 = (CC64K) 8kHz reference, (T1) normal sync pulses 1 = (CC64K) 400Hz reference, (T1) double-wide sync pulses during signaling frames Bit 4: RLOF_CCE Output Function (RLOFF). In T1 or E1 receive mode, this bit determines the function of the RLOF_CCE pin. In 64KCC or 6312kHz receive mode, this bit should be set = 0. 0 = receive loss of frame (RLOF) 1 = loss-of-transmit clock (LOTC) Bit 5: RS_8K Mode Select 1(RSMS1). In T1 or E1 receive mode, this bit selects a frame or multiframe output pulse at RS_8K pin. IOCR.6 may be used to select other functions for the RS_8K pin. 0 = frame mode 1 = multiframe mode Bit 6: RS_8K Mode Select 2 (RSMS2). In T1 and E1 receive mode, this bit along with IOCR.5 selects the function of the RS_8K pin. T1 Mode: (when IOCR.5 set = 0) 0 = do not pulse double-wide in signaling frames 1 = do pulse double-wide in signaling frames E1 Mode: (when IOCR.5 set = 1) 0 = RS_8K outputs CAS multiframe boundaries 1 = RS_8K outputs CRC4 multiframe boundaries Bit 7: G.703 Timing Enable (G703TE). Setting this bit causes the 8kHz and 400Hz outputs to have timing relationships to the 64kHz composite clock signal as specified in G.703. This bit allows backward compatibility with earlier devices in the DS2650x family. Note: This applies to 64KCC modes only. 0 = legacy timing mode 1 = G.703 timing mode 53 of 129 DS26504 T1/E1/J1/64KCC BITS Element Table 10-1. TS_8K_4 Pin Functions TRANSMIT MODE T1/E1 T1/E1 T1/E1 T1/E1 64KCC 64KCC 64KCC 64KCC IOCR1.3 IOCR1.2 IOCR1.1 TS_8K_4 FUNCTION 0 0 0 0 0 0 1 1 0 0 1 1 0 0 0 0 0 1 0 1 0 1 0 1 Frame sync input Frame sync output Multiframe sync input Multiframe sync output 8kHz input reference 8kHz output reference 400Hz input reference 400Hz output reference Table 10-2. RLOF_CCE Pin Functions RECEIVE MODE T1/E1 T1/E1 64KCC IOCR1.4 RLOF_CCE PIN FUNCTION 0 1 0 Indicate Loss of Frame Indicates Loss-of-Transmit Clock Indicates Composite Clock Error 54 of 129 DS26504 T1/E1/J1/64KCC BITS Element Register Name: Register Description: Register Address: Bit # Name Default HW Mode IOCR2 I/O Configuration Register 2 02h 7 RCLKINV 6 TCLKINV 5 RS_8KINV 0 0 0 0 4 TS_8K_4INV 3 — 2 — 1 TPCOE 0 RPCOE 0 0 0 0 0 0 0 0 0 0 0 0 Bit 0: Receive Payload Clock Output Enable (RPCOE). Setting this bit enables a gapped receive clock at the RCLK pin. In E1 mode, the clock is gapped during TS0 and TS16. In T1 mode, the clock is gapped during the F-Bit. Note: This function is only available in T1 or E1 mode. Bit 1: Transmit Payload Clock Output Enable (TPCOE). Setting this bit enables a gapped transmit clock at the TCLKO pin. In E1 mode, the clock is gapped during TS0 and TS16. In T1 mode, the clock is gapped during the F-Bit. Note: This function is only available in T1 or E1 mode. Bits 2 and 3: Unused, must be set = 0 for proper operation. Bit 4: TS_8K_4 Invert (TS_8K_4INV) 0 = no inversion 1 = invert Bit 5: RS_8K Invert (RS_8KINV) 0 = no inversion 1 = invert Bit 6: TCLK Invert (TCLKINV) 0 = no inversion 1 = invert Bit 7: RCLK Invert (RCLKINV) 0 = no inversion 1 = invert 55 of 129 DS26504 T1/E1/J1/64KCC BITS Element 11. T1 SYNCHRONIZATION STATUS MESSAGE The DS26504 has a BOC controller to handle SSM services in T1 mode. Table 11-1. T1 SSM Messages QUALITY LEVEL 1 2 3 4 5 6 7 User Assignable DESCRIPTION BOC CODE Stratum 1 Traceable Synchronized Traceablity Unknown Stratum 2 Traceable Stratum 3 Traceable SONET Minimum Clock Traceable Stratum 4 Traceable Do Not Use for Synchronization Reserved for Network Synchronization Use 0000010011111111 0000100011111111 0000110011111111 0001000011111111 0010001011111111 0010100011111111 0011000011111111 0100000011111111 11.1 T1 Bit-Oriented Code (BOC) Controller The DS26504 contains a BOC generator on the transmit side and a BOC detector on the receive side. The BOC function is available only in T1 mode. In typical BITS applications, the BOC controller would be used to transmit and receive Synchronization Status Messages in T1 mode over the data link. 11.2 Transmit BOC Bits 0 through 5 in the TFDL register contain the BOC or synchronization status message to be transmitted. Setting BOCC.0 = 1 causes the transmit BOC controller to immediately begin inserting the BOC sequence into the FDL bit position. The transmit BOC controller automatically provides the abort sequence. BOC messages will be transmitted as long as BOCC.0 is set. TFSE (T1TCR2.6) must be set = 0 when using the transmit BOC function. To transmit a BOC, use the following: 1) Write 6-bit code into the TFDL register. 2) Set SBOC bit in BOCC register = 1. 56 of 129 DS26504 T1/E1/J1/64KCC BITS Element 11.3 Receive BOC The receive BOC function is enabled by setting BOCC.4 = 1. The RFDL register will now operate as the receive BOC message and information register. The lower six bits of the RFDL register (BOC message bits) are preset to all ones. When the BOC bits change state, the BOC change of state indicator, SR3.0, alerts the host. The host then reads the RFDL register to get the BOC message. A change of state occurs when either a new BOC code has been present for time determined by the receive BOC filter bits, RBF0 and RBF1, in the BOCC register. To receive a BOC, use the following: 1) 2) 3) 4) 5) 6) Set integration time via BOCC.1 and BOCC.2. Enable the receive BOC function (BOCC.4 = 1). Enable interrupt (IMR3.0 = 1). Wait for interrupt to occur. Read the RFDL register. The lower six bits of the RFDL register is the message. 57 of 129 DS26504 T1/E1/J1/64KCC BITS Element Register Name: Register Description: Register Address: BOCC BOC Control Register 1Fh Bit # Name Default HW Mode 7 — 0 6 — 0 5 — 0 4 RBOCE 0 3 RBR 0 2 RBF1 0 1 RBF0 0 0 SBOC 0 0 0 0 0 0 0 0 0 Bit 0: Send BOC (SBOC). Set = 1 to transmit the BOC code placed in bits 0 to 5 of the TFDL register. Bits 1 and 2: Receive BOC Filter Bits (RBF0, RBF1). The BOC filter sets the number of consecutive patterns that must be received without error prior to an indication of a valid message. RBF1 RBF0 0 0 1 1 0 1 0 1 CONSECUTIVE BOC CODES FOR VALID SEQUENCE IDENTIFICATION None 3 5 7 Bit 3: Receive BOC Reset (RBR). A zero-to-one transition resets the BOC circuitry. Must be cleared and set again for a subsequent reset. Bit 4: Receive BOC Enable (RBOCE). Enables the receive BOC function. The RFDL register reports the received BOC code. 0 = receive BOC function disabled 1 = receive BOC function enabled. The RFDL register reports BOC messages. Bits 5, 6, 7: Unused, must be set = 0 for proper operation. 58 of 129 DS26504 T1/E1/J1/64KCC BITS Element Register Name: Register Description: Register Address: RFDL (RFDL register bit usage when BOCC.4 = 1) Receive FDL Register 50h Bit # Name Default HW Mode 7 — 0 6 — 0 5 RBOC5 0 4 RBOC4 0 3 RBOC3 0 2 RBOC2 0 1 RBOC1 0 0 RBOC0 0 0 0 0 0 0 0 0 0 Bit 0: BOC Bit 0 (RBOC0) Bit 1: BOC Bit 1 (RBOC1) Bit 2: BOC Bit 2 (RBOC2) Bit 3: BOC Bit 3 (RBOC3) Bit 4: BOC Bit 4 (RBOC4) Bit 5: BOC Bit 5 (RBOC5) Bits 6 and 7: This bit position is unused when BOCC.4 = 1. Register Name: Register Description: Register Address: Bit # Name Default HW Mode RFDLM1, RFDLM2 Receive FDL Match Register 1, Receive FDL Match Register 2 52h, 53h 7 RFDLM7 0 6 RFDLM6 0 5 RFDLM5 0 4 RFDLM4 0 3 RFDLM3 0 2 RFDLM2 0 1 RFDLM1 0 0 RFDLM0 0 0 0 0 0 0 0 0 0 Bit 0: Receive FDL Match Bit 0 (RFDLM0). LSB of the FDL Match Code. Bit 1: Receive FDL Match Bit 1 (RFDLM1) Bit 2: Receive FDL Match Bit 2 (RFDLM2) Bit 3: Receive FDL Match Bit 3 (RFDLM3) Bit 4: Receive FDL Match Bit 4 (RFDLM4) Bit 5: Receive FDL Match Bit 5 (RFDLM5) Bit 6: Receive FDL Match Bit 6 (RFDLM6) Bit 7: Receive FDL Match Bit 7 (RFDLM7). MSB of the FDL Match Code. 59 of 129 DS26504 T1/E1/J1/64KCC BITS Element Register Name: Register Description: Register Address: Bit # Name Default HW Mode SR3 Status Register 3 18h 7 — 0 6 LOTC 0 5 BOCC 0 4 RFDLAD 0 3 RFDLF 0 2 TFDLE 0 1 RMTCH 0 0 RBOC 0 X X X X X X X X Bit 0: Receive BOC Detector Change-of-State Event (RBOC). Set whenever the BOC detector sees a change of state to a valid BOC. The setting of this bit prompts the user to read the RFDL register. Bit 1: Receive FDL Match Event (RMTCH). Set whenever the contents of the RFDL register matches RFDLM1 or RFDLM2. Bit 2: TFDL Register Empty Event (TFDLE). Set when the transmit FDL buffer (TFDL) empties. Bit 3: RFDL Register Full Event (RFDLF). Set when the receive FDL buffer (RFDL) fills to capacity. Bit 4: RFDL Abort Detect Event (RFDLAD). Set when eight consecutive ones are received on the FDL. Bit 5: BOC Clear Event (BOCC). Set when 30 FDL bits occur without an abort sequence. Bit 6: Loss-of-Transmit Clock Event (LOTC). Set when the signal at the TCLK pin has not transitioned for approximately 15 periods of the scaled MCLK. Bit 7: Unused 60 of 129 DS26504 T1/E1/J1/64KCC BITS Element Register Name: Register Description: Register Address: Bit # Name Default HW Mode IMR3 Interrupt Mask Register 3 19h 7 — 0 6 LOTC 0 5 BOCC 0 4 RFDLAD 0 3 RFDLF 0 2 TFDLE 0 1 RMTCH 0 0 RBOC 0 X X X X X X X X Bit 0: Receive BOC Detector Change-of-State Event (RBOC) 0 = interrupt masked 1 = interrupt enabled Bit 1: Receive FDL Match Event (RMTCH) 0 = interrupt masked 1 = interrupt enabled Bit 2: TFDL Register Empty Event (TFDLE) 0 = interrupt masked 1 = interrupt enabled Bit 3: RFDL Register Full Event (RFDLF) 0 = interrupt masked 1 = interrupt enabled Bit 4: RFDL Abort Detect Event (RFDLAD) 0 = interrupt masked 1 = interrupt enabled Bit 5: BOC Clear Event (BOCC) 0 = interrupt masked 1 = interrupt enabled Bit 6: Loss-of-Transmit Clock Event (LOTC) 0 = interrupt masked 1 = interrupt enabled Bit 7: Unused, must be set = 0 for proper operation. 61 of 129 DS26504 T1/E1/J1/64KCC BITS Element Register Name: Register Description: Register Address: Bit # Name Default HW Mode SR4 Status Register 4 1Ah 7 — 0 6 RSA1 0 5 RSA0 0 4 TMF 0 3 TAF 0 2 RMF 0 1 RCMF 0 0 RAF 0 X X X X X X X X Bit 0: Receive Align Frame Event (RAF). (E1 only) Set every 250µs at the beginning of align frames. Used to alert the host that Si and Sa bits are available in the RAF and RNAF registers. Bit 1: Receive CRC4 Multiframe Event (RCMF). (E1 only) Set on CRC4 multiframe boundaries; will continue to be set every 2ms on an arbitrary boundary if CRC4 is disabled. Bit 2: Receive Multiframe Event (RMF) E1 Mode: Set every 2ms (regardless if CAS signaling is enabled or not) on receive multiframe boundaries. Used to alert the host that signaling data is available. T1 Mode: Set every 1.5ms on D4 MF boundaries or every 3ms on ESF MF boundaries. Bit 3: Transmit Align Frame Event (TAF). (E1 only) Set every 250µs at the beginning of align frames. Used to alert the host that the TAF and TNAF registers need to be updated. Bit 4: Transmit Multiframe Event (TMF) E1 Mode: Set every 2ms (regardless if CRC4 is enabled) on transmit multiframe boundaries. Used to alert the host that signaling data needs to be updated. T1 Mode: Set every 1.5ms on D4 MF boundaries or every 3ms on ESF MF boundaries. Bit 5: Receive Signaling All Zeros Event (RSA0). (E1 only) Set when over a full MF, time slot 16 contains all zeros. Bit 6: Receive Signaling All Ones Event (RSA1). (E1 only) Set when the contents of time slot 16 contains fewer than three zeros over 16 consecutive frames. This alarm is not disabled in the CCS signaling mode. Bit 7: Unused 62 of 129 DS26504 T1/E1/J1/64KCC BITS Element Register Name: Register Description: Register Address: Bit # Name Default HW Mode IMR4 Interrupt Mask Register 4 1Bh 7 — 0 6 RSA1 0 5 RSA0 0 4 TMF 0 3 TAF 0 2 RMF 0 1 RCMF 0 0 RAF 0 X X X X X X X X Bit 0: Receive Align Frame Event (RAF) 0 = interrupt masked 1 = interrupt enabled Bit 1: Receive CRC4 Multiframe Event (RCMF) 0 = interrupt masked 1 = interrupt enabled Bit 2: Receive Multiframe Event (RMF) 0 = interrupt masked 1 = interrupt enabled Bit 3: Transmit Align Frame Event (TAF) 0 = interrupt masked 1 = interrupt enabled Bit 4: Transmit Multiframe Event (TMF) 0 = interrupt masked 1 = interrupt enabled Bit 5: Receive Signaling All-Zeros Event (RSA0) 0 = interrupt masked 1 = interrupt enabled Bit 6: Receive Signaling All-Ones Event (RSA1) 0 = interrupt masked 1 = interrupt enabled Bit 7: Unused, must be set = 0 for proper operation. 63 of 129 DS26504 T1/E1/J1/64KCC BITS Element Register Name: Register Description: Register Address: Bit # Name Default HW Mode TFDL Transmit FDL Register 51h 7 TFDL7 0 6 TFDL6 0 5 TFDL5 0 4 TFDL4 0 3 TFDL3 0 2 TFDL2 0 1 TFDL1 0 0 TFDL0 0 0 0 0 1 1 1 0 0 Note: Also used to insert Fs framing pattern in D4 framing mode. The transmit FDL register (TFDL) contains the FDL information that is to be inserted on a byte-basis into the outgoing T1 data stream. The LSB is transmitted first. Bit 0: Transmit FDL Bit 0 (TFDL0). LSB of the transmit FDL code. Bit 1: Transmit FDL Bit 1 (TFDL1) Bit 2: Transmit FDL Bit 2 (TFDL2) Bit 3: Transmit FDL Bit 3 (TFDL3) Bit 4: Transmit FDL Bit 4 (TFDL4) Bit 5: Transmit FDL Bit 5 (TFDL5) Bit 6: Transmit FDL Bit 6 (TFDL6) Bit 7: Transmit FDL Bit 7 (TFDL7). MSB of the transmit FDL code. 64 of 129 DS26504 T1/E1/J1/64KCC BITS Element 12. E1 SYNCHRONIZATION STATUS MESSAGE The DS26504 provides access to both the transmit and receive Sa/Si bits. In E1, the Sa bits are used to transmit and receive the SSM. The primary method to access the Sa (and Si) bits is based on CRC4 multiframe access. An alternate method is based on double-frame access. The DS26504 provides an interrupt on a change of state for the Sa-bit-based messages. Table 12-1. E1 SSM Messages QUALITY LEVEL 0 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 DESCRIPTION Quality unknown (existing sync network) Reserved Rec. G.811 (Traceable to PRS) Reserved SSU-A (Traceable to SSU type A, see G.812) Reserved Reserved Reserved SSU-B (Traceable to SSU type B, see G.812) Reserved Reserved Synchronous Equipment Timing Source Reserved Reserved Reserved Do not use for synchronization Sa BIT MESSAGE 0000 0001 0010 0011 0100 0101 0110 0111 1000 1001 1010 1011 1100 1101 1110 1111 In E1 operation, SSMs are transmitted using one of the Sa bits—Sa4, Sa5, Sa6, Sa7, or Sa8. The SSM is transmitted MSB first in the first frame of the multiframe. Each multiframe will contain two SSMs, one in each sub-multiframe. An SSM is declared valid when the message in three sub-multiframes are alike. 12.1 Sa/Si Bit Access Based on CRC4 Multiframe On the receive side, there is a set of eight registers (RsiAF, RSiNAF, RRA, Rsa4 to Rsa8) that report the Si and Sa bits as they are received. These registers are updated on CRC4 multiframes. A bit in Status Register 4 (SR4.1) indicates the multiframe boundary. The host can use the SR4.1 bit to know when to read these registers. The user has 2ms to retrieve the data before it is lost. The MSB of each register is the first received. See the following register descriptions for more details. On the transmit side, there is also a set of eight registers (TsiAF, TSiNAF, TRA, Tsa4 to Tsa8) that, via the transmit Sa bit control register (TsaCR), can be programmed to insert both Si and Sa data. Data is sampled from these registers with the setting of the transmit multiframe bit in status register 2 (SR4.4). The host can use the SR4.4 bit to know when to update these registers. It has 2ms to update the data or else the old data will be retransmitted. The MSB of each register is the first bit transmitted. See the following register descriptions for details. 65 of 129 DS26504 T1/E1/J1/64KCC BITS Element 12.1.1 Sa Bit Change of State The DS26504 can provide an interrupt whenever one of the multiframe based Sa bit patterns changes. Using the SR5 and IMR5 registers, the user can enable interrupts on a change of state for Sa4, Sa5, Sa6, Sa7 and Sa8 multiframe bit patterns. This function is useful for monitoring the Sa6-based SSM message. Register Name: Register Description: Register Address: SR5 Status Register 5 21h Bit # Name Default HW Mode 7 — 0 6 — 0 5 — 0 4 Sa8COS 0 3 Sa7COS 0 2 Sa6COS 0 1 Sa5COS 0 0 Sa4COS 0 X X X X X X X X Bit 0: Sa4 Change of State (Sa4COS). Set when any Sa4 bit in the 16-frame multiframe has changed state. Bit 1: Sa5 Change of State (Sa5COS). Set when any Sa5 bit in the 16-frame multiframe has changed state. Bit 2: Sa6 Change of State (Sa6COS). Set when any Sa6 bit in the 16-frame multiframe has changed state. Bit 3: Sa7 Change of State (Sa7COS). Set when any Sa7 bit in the 16-frame multiframe has changed state. Bit 4: Sa8 Change of State (Sa8COS). Set when any Sa8 bit in the 16-frame multiframe has changed state. Bits 5, 6, 7: Unused 66 of 129 DS26504 T1/E1/J1/64KCC BITS Element Register Name: Register Description: Register Address: IMR5 Interrupt Mask Register 5 22h Bit # Name Default HW Mode 7 — 0 6 — 0 5 — 0 4 Sa8COS 0 3 Sa7COS 0 2 Sa6COS 0 1 Sa5COS 0 0 Sa4COS 0 X X X X X X X X Bit 0: Sa4 Change of State (Sa4COS) 0 = interrupt masked 1 = interrupt enabled Bit 1: Sa5 Change of State (Sa5COS) 0 = interrupt masked 1 = interrupt enabled Bit 2: Sa6 Change of State (Sa6COS) 0 = interrupt masked 1 = interrupt enabled Bit 3: Sa7 Change of State (Sa7COS) 0 = interrupt masked 1 = interrupt enabled Bit 4: Sa8 Change of State (Sa8COS) 0 = interrupt masked 1 = interrupt enabled Bits 5, 6, 7: Unused, must be set = 0 for proper operation. 67 of 129 DS26504 T1/E1/J1/64KCC BITS Element Register Name: Register Description: Register Address: Bit # Name Default HW Mode RsiAF Receive Si Bits of the Align Frame 58h 7 SiF0 0 6 SiF2 0 5 SiF4 0 4 SiF6 0 3 SiF8 0 2 SiF10 0 1 SiF12 0 0 SiF14 0 X X X X X X X X Bit 0: Si Bit of Frame 14(SiF14) Bit 1: Si Bit of Frame 12(SiF12) Bit 2: Si Bit of Frame 10(SiF10) Bit 3: Si Bit of Frame 8(SiF8) Bit 4: Si Bit of Frame 6(SiF6) Bit 5: Si Bit of Frame 4(SiF4) Bit 6: Si Bit of Frame 2(SiF2) Bit 7: Si Bit of Frame 0(SiF0) Register Name: Register Description: Register Address: Bit # Name Default HW Mode RSiNAF Receive Si Bits of the Non-Align Frame 59h 7 SiF1 0 6 SiF3 0 5 SiF5 0 4 SiF7 0 3 SiF9 0 2 SiF11 0 1 SiF13 0 0 SiF15 0 X X X X X X X X Bit 0: Si Bit of Frame 15(SiF15) Bit 1: Si Bit of Frame 13(SiF13) Bit 2: Si Bit of Frame 11(SiF11) Bit 3: Si Bit of Frame 9(SiF9) Bit 4: Si Bit of Frame 7(SiF7) Bit 5: Si Bit of Frame 5(SiF5) Bit 6: Si Bit of Frame 3(SiF3) Bit 7: Si Bit of Frame 1(SiF1) 68 of 129 DS26504 T1/E1/J1/64KCC BITS Element Register Name: Register Description: Register Address: Bit # Name Default HW Mode RRA Receive Remote Alarm 5Ah 7 RRAF1 0 6 RRAF3 0 5 RRAF5 0 4 RRAF7 0 3 RRAF9 0 2 RRAF11 0 1 RRAF13 0 0 RRAF15 0 X X X X X X X X Bit 0: Remote Alarm Bit of Frame 15(RRAF15) Bit 1: Remote Alarm Bit of Frame 13(RRAF13) Bit 2: Remote Alarm Bit of Frame 11(RRAF11) Bit 3: Remote Alarm Bit of Frame 9(RRAF9) Bit 4: Remote Alarm Bit of Frame 7(RRAF7) Bit 5: Remote Alarm Bit of Frame 5(RRAF5) Bit 6: Remote Alarm Bit of Frame 3(RRAF3) Bit 7: Remote Alarm Bit of Frame 1(RRAF1) Register Name: Register Description: Register Address: Bit # Name Default HW Mode Rsa4 Receive Sa4 Bits 5Bh 7 Rsa4F1 0 6 Rsa4F3 0 5 Rsa4F5 0 4 Rsa4F7 0 3 Rsa4F9 0 2 Rsa4F11 0 1 Rsa4F13 0 0 Rsa4F15 0 X X X X X X X X Bit 0: Sa4 Bit of Frame 15(Rsa4F15) Bit 1: Sa4 Bit of Frame 13(Rsa4F13) Bit 2: Sa4 Bit of Frame 11(Rsa4F11) Bit 3: Sa4 Bit of Frame 9(Rsa4F9) Bit 4: Sa4 Bit of Frame 7(Rsa4F7) Bit 5: Sa4 Bit of Frame 5(Rsa4F5) Bit 6: Sa4 Bit of Frame 3(Rsa4F3) Bit 7: Sa4 Bit of Frame 1(Rsa4F1) 69 of 129 DS26504 T1/E1/J1/64KCC BITS Element Register Name: Register Description: Register Address: Bit # Name Default HW Mode Rsa5 Receive Sa5 Bits 5Ch 7 Rsa5F1 0 6 Rsa5F3 0 5 Rsa5F5 0 4 Rsa5F7 0 3 Rsa5F9 0 2 Rsa5F11 0 1 Rsa5F13 0 0 Rsa5F15 0 X X X X X X X X Bit 0: Sa5 Bit of Frame 15(Rsa5F15) Bit 1: Sa5 Bit of Frame 13(Rsa5F13) Bit 2: Sa5 Bit of Frame 11(Rsa5F11) Bit 3: Sa5 Bit of Frame 9(Rsa5F9) Bit 4: Sa5 Bit of Frame 7(Rsa5F7) Bit 5: Sa5 Bit of Frame 5(Rsa5F5) Bit 6: Sa5 Bit of Frame 3(Rsa5F3) Bit 7: Sa5 Bit of Frame 1(Rsa5F1) Register Name: Register Description: Register Address: Bit # Name Default HW Mode Rsa6 Receive Sa6 Bits 5Dh 7 Rsa6F1 0 6 Rsa6F3 0 5 Rsa6F5 0 4 Rsa6F7 0 3 Rsa6F9 0 2 Rsa6F11 0 1 Rsa6F13 0 0 Rsa6F15 0 X X X X X X X X Bit 0: Sa6 Bit of Frame 15(Rsa6F15) Bit 1: Sa6 Bit of Frame 13(Rsa6F13) Bit 2: Sa6 Bit of Frame 11(Rsa6F11) Bit 3: Sa6 Bit of Frame 9(Rsa6F9) Bit 4: Sa6 Bit of Frame 7(Rsa6F7) Bit 5: Sa6 Bit of Frame 5(Rsa6F5) Bit 6: Sa6 Bit of Frame 3(Rsa6F3) Bit 7: Sa6 Bit of Frame 1(Rsa6F1) 70 of 129 DS26504 T1/E1/J1/64KCC BITS Element Register Name: Register Description: Register Address: Bit # Name Default HW Mode Rsa7 Receive Sa7 Bits 5Eh 7 Rsa7F1 0 6 Rsa7F3 0 5 Rsa7F5 0 4 Rsa7F7 0 3 Rsa7F9 0 2 Rsa7F11 0 1 Rsa7F13 0 0 Rsa7F15 0 X X X X X X X X Bit 0: Sa7 Bit of Frame 15(Rsa7F15) Bit 1: Sa7 Bit of Frame 13(Rsa7F13) Bit 2: Sa7 Bit of Frame 11(Rsa7F11) Bit 3: Sa7 Bit of Frame 9(Rsa7F9) Bit 4: Sa7 Bit of Frame 7(Rsa7F7) Bit 5: Sa7 Bit of Frame 5(Rsa7F5) Bit 6: Sa7 Bit of Frame 3(Rsa7F3) Bit 7: Sa7 Bit of Frame 1(Rsa4F1) Register Name: Register Description: Register Address: Bit # Name Default HW Mode Rsa8 Receive Sa8 Bits 5Fh 7 Rsa8F1 0 6 Rsa8F3 0 5 Rsa8F5 0 4 Rsa8F7 0 3 Rsa8F9 0 2 Rsa8F11 0 1 Rsa8F13 0 0 Rsa8F15 0 X X X X X X X X Bit 0: Sa8 Bit of Frame 15(Rsa8F15) Bit 1: Sa8 Bit of Frame 13(Rsa8F13) Bit 2: Sa8 Bit of Frame 11(Rsa8F11) Bit 3: Sa8 Bit of Frame 9(Rsa8F9) Bit 4: Sa8 Bit of Frame 7(Rsa8F7) Bit 5: Sa8 Bit of Frame 5(Rsa8F5) Bit 6: Sa8 Bit of Frame 3(Rsa8F3) Bit 7: Sa8 Bit of Frame 1(Rsa8F1) 71 of 129 DS26504 T1/E1/J1/64KCC BITS Element Register Name: Register Description: Register Address: Bit # Name Default HW Mode TsiAF Transmit Si Bits of the Align Frame 42h 7 TsiF0 0 6 TsiF2 0 5 TsiF4 0 4 TsiF6 0 3 TsiF8 0 2 TsiF10 0 1 TsiF12 0 0 TsiF14 0 0 0 0 0 0 0 0 0 Bit 0: Si Bit of Frame 14(TsiF14) Bit 1: Si Bit of Frame 12(TsiF12) Bit 2: Si Bit of Frame 10(TsiF10) Bit 3: Si Bit of Frame 8(TsiF8) Bit 4: Si Bit of Frame 6(TsiF6) Bit 5: Si Bit of Frame 4(TsiF4) Bit 6: Si Bit of Frame 2(TsiF2) Bit 7: Si Bit of Frame 0(TsiF0) Register Name: Register Description: Register Address: Bit # Name Default HW Mode TSiNAF Transmit Si Bits of the Non-Align Frame 43h 7 TsiF1 0 6 TsiF3 0 5 TsiF5 0 4 TsiF7 0 3 TsiF9 0 2 TsiF11 0 1 TsiF13 0 0 TsiF15 0 0 0 0 0 0 0 0 0 Bit 0: Si Bit of Frame 15(TsiF15) Bit 1: Si Bit of Frame 13(TsiF13) Bit 2: Si Bit of Frame 11(TsiF11) Bit 3: Si Bit of Frame 9(TsiF9) Bit 4: Si Bit of Frame 7(TsiF7) Bit 5: Si Bit of Frame 5(TsiF5) Bit 6: Si Bit of Frame 3(TsiF3) Bit 7: Si Bit of Frame 1(TsiF1) 72 of 129 DS26504 T1/E1/J1/64KCC BITS Element Register Name: Register Description: Register Address: Bit # Name Default HW Mode TRA Transmit Remote Alarm 44h 7 TRAF1 0 6 TRAF3 0 5 TRAF5 0 4 TRAF7 0 3 TRAF9 0 2 TRAF11 0 1 TRAF13 0 0 TRAF15 0 0 0 0 0 0 0 0 0 Bit 0: Remote Alarm Bit of Frame 15(TRAF15) Bit 1: Remote Alarm Bit of Frame 13(TRAF13) Bit 2: Remote Alarm Bit of Frame 11(TRAF11) Bit 3: Remote Alarm Bit of Frame 9(TRAF9) Bit 4: Remote Alarm Bit of Frame 7(TRAF7) Bit 5: Remote Alarm Bit of Frame 5(TRAF5) Bit 6: Remote Alarm Bit of Frame 3(TRAF3) Bit 7: Remote Alarm Bit of Frame 1(TRAF1) Register Name: Register Description: Register Address: Bit # Name Default HW Mode Tsa4 Transmit Sa4 Bits 45h 7 Tsa4F1 0 6 Tsa4F3 0 5 Tsa4F5 0 4 Tsa4F7 0 3 Tsa4F9 0 2 Tsa4F11 0 1 Tsa4F13 0 0 Tsa4F15 0 0 0 0 0 0 0 0 0 Bit 0: Sa4 Bit of Frame 15(Tsa4F15) Bit 1: Sa4 Bit of Frame 13(Tsa4F13) Bit 2: Sa4 Bit of Frame 11(Tsa4F11) Bit 3: Sa4 Bit of Frame 9(Tsa4F9) Bit 4: Sa4 Bit of Frame 7(Tsa4F7) Bit 5: Sa4 Bit of Frame 5(Tsa4F5) Bit 6: Sa4 Bit of Frame 3(Tsa4F3) Bit 7: Sa4 Bit of Frame 1(Tsa4F1) 73 of 129 DS26504 T1/E1/J1/64KCC BITS Element Register Name: Register Description: Register Address: Bit # Name Default HW Mode Tsa5 Transmit Sa5 Bits 46h 7 Tsa5F1 0 6 Tsa5F3 0 5 Tsa5F5 0 4 Tsa5F7 0 3 Tsa5F9 0 2 Tsa5F11 0 1 Tsa5F13 0 0 Tsa5F15 0 0 0 0 0 0 0 0 0 Bit 0: Sa5 Bit of Frame 15(Tsa5F15) Bit 1: Sa5 Bit of Frame 13(Tsa5F13) Bit 2: Sa5 Bit of Frame 11(Tsa5F11) Bit 3: Sa5 Bit of Frame 9(Tsa5F9) Bit 4: Sa5 Bit of Frame 7(Tsa5F7) Bit 5: Sa5 Bit of Frame 5(Tsa5F5) Bit 6: Sa5 Bit of Frame 3(Tsa5F3) Bit 7: Sa5 Bit of Frame 1(Tsa5F1) Register Name: Register Description: Register Address: Bit # Name Default HW Mode Tsa6 Transmit Sa6 Bits 47h 7 Tsa6F1 0 6 Tsa6F3 0 5 Tsa6F5 0 4 Tsa6F7 0 3 Tsa6F9 0 2 Tsa6F11 0 1 Tsa6F13 0 0 Tsa6F15 0 0 0 0 0 0 0 0 0 Bit 0: Sa6 Bit of Frame 15(Tsa6F15) Bit 1: Sa6 Bit of Frame 13(Tsa6F13) Bit 2: Sa6 Bit of Frame 11(Tsa6F11) Bit 3: Sa6 Bit of Frame 9(Tsa6F9) Bit 4: Sa6 Bit of Frame 7(Tsa6F7) Bit 5: Sa6 Bit of Frame 5(Tsa6F5) Bit 6: Sa6 Bit of Frame 3(Tsa6F3) Bit 7: Sa6 Bit of Frame 1(Tsa6F1) 74 of 129 DS26504 T1/E1/J1/64KCC BITS Element Register Name: Register Description: Register Address: Bit # Name Default HW Mode Tsa7 Transmit Sa7 Bits 48h 7 Tsa7F1 0 6 Tsa7F3 0 5 Tsa7F5 0 4 Tsa7F7 0 3 Tsa7F9 0 2 Tsa7F11 0 1 Tsa7F13 0 0 Tsa7F15 0 0 0 0 0 0 0 0 0 Bit 0: Sa7 Bit of Frame 15(Tsa7F15) Bit 1: Sa7 Bit of Frame 13(Tsa7F13) Bit 2: Sa7 Bit of Frame 11(Tsa7F11) Bit 3: Sa7 Bit of Frame 9(Tsa7F9) Bit 4: Sa7 Bit of Frame 7(Tsa7F7) Bit 5: Sa7 Bit of Frame 5(Tsa7F5) Bit 6: Sa7 Bit of Frame 3(Tsa7F3) Bit 7: Sa7 Bit of Frame 1(Tsa4F1) Register Name: Register Description: Register Address: Bit # Name Default HW Mode Tsa8 Transmit Sa8 Bits 49h 7 Tsa8F1 0 6 Tsa8F3 0 5 Tsa8F5 0 4 Tsa8F7 0 3 Tsa8F9 0 2 Tsa8F11 0 1 Tsa8F13 0 0 Tsa8F15 0 0 0 0 0 0 0 0 0 Bit 0: Sa8 Bit of Frame 15(Tsa8F15) Bit 1: Sa8 Bit of Frame 13(Tsa8F13) Bit 2: Sa8 Bit of Frame 11(Tsa8F11) Bit 3: Sa8 Bit of Frame 9(Tsa8F9) Bit 4: Sa8 Bit of Frame 7(Tsa8F7) Bit 5: Sa8 Bit of Frame 5(Tsa8F5) Bit 6: Sa8 Bit of Frame 3(Tsa8F3) Bit 7: Sa8 Bit of Frame 1(Tsa8F1) 75 of 129 DS26504 T1/E1/J1/64KCC BITS Element Register Name: Register Description: Register Address: Bit # Name Default HW Mode TSACR Transmit Sa Bit Control Register 4Ah 7 SiAF 0 6 SiNAF 0 5 RA 0 4 Sa4 0 3 Sa5 0 2 Sa6 0 1 Sa7 0 0 Sa8 0 0 0 0 0 0 0 0 0 Bit 0: Additional Bit 8 Insertion Control Bit (Sa8) 0 = do not insert data from the Tsa8 register into the transmit data stream 1 = insert data from the Tsa8 register into the transmit data stream Bit 1: Additional Bit 7 Insertion Control Bit (Sa7) 0 = do not insert data from the Tsa7 register into the transmit data stream 1 = insert data from the Tsa7 register into the transmit data stream Bit 2: Additional Bit 6 Insertion Control Bit (Sa6) 0 = do not insert data from the Tsa6 register into the transmit data stream 1 = insert data from the Tsa6 register into the transmit data stream Bit 3: Additional Bit 5 Insertion Control Bit (Sa5) 0 = do not insert data from the Tsa5 register into the transmit data stream 1 = insert data from the Tsa5 register into the transmit data stream Bit 4: Additional Bit 4 Insertion Control Bit (Sa4) 0 = do not insert data from the Tsa4 register into the transmit data stream 1 = insert data from the Tsa4 register into the transmit data stream Bit 5: Remote Alarm Insertion Control Bit (RA) 0 = do not insert data from the TRA register into the transmit data stream 1 = insert data from the TRA register into the transmit data stream Bit 6: International Bit in Non-Align Frame Insertion Control Bit (SiNAF) 0 = do not insert data from the TSiNAF register into the transmit data stream 1 = insert data from the TSiNAF register into the transmit data stream Bit 7: International Bit in Align Frame Insertion Control Bit (SiAF) 0 = do not insert data from the TsiAF register into the transmit data stream 1 = insert data from the TsiAF register into the transmit data stream 76 of 129 DS26504 T1/E1/J1/64KCC BITS Element 12.2 Alternate Sa/Si Bit Access Based on Double-Frame On the receive side, the RAF and RNAF registers will always report the data as it received in the Sa and Si bit locations. The RAF and RNAF registers are updated on align frame boundaries. The setting of the receive align frame bit in status register 4 (SR4.0) will indicate that the contents of the RAF and RNAF have been updated. The host can use the SR4.0 bit to know when to read the RAF and RNAF registers. The host has 250μs to retrieve the data before it is lost. On the transmit side, data is sampled from the TAF and TNAF registers with the setting of the transmit align frame bit in status register 4 (SR4.3). The host can use the SR4.3 bit to know when to update the TAF and TNAF registers. It has 250μs to update the data or else the old data will be retransmitted. If the TAF and TNAF registers are only being used to source the align frame and non-align frame-sync patterns, then the host need only write once to these registers. Data for the Si bit can come from the Si bits of the RAF and TNAF registers, the TsiAF and TSiNAF registers, or passed through from the TSER pin. Register Name: Register Description: Register Address: Bit # Name Default HW Mode RAF Receive Align Frame Register 56h 7 Si 0 6 FAS6 0 5 FAS5 0 4 FAS4 0 3 FAS3 0 2 FAS2 0 1 FAS1 0 0 FAS0 0 X X X X X X X X Bit 0: Frame Alignment Signal Bit 0 (FAS0). In normal operation this bit will be = 1. Bit 1: Frame Alignment Signal Bit 1 (FAS1). In normal operation this bit will be = 1. Bit 2: Frame Alignment Signal Bit 2 (FAS2). In normal operation this bit will be = 0. Bit 3: Frame Alignment Signal Bit 3 (FAS3). In normal operation this bit will be = 1. Bit 4: Frame Alignment Signal Bit 4 (FAS4). In normal operation this bit will be = 1. Bit 5: Frame Alignment Signal Bit 5 (FAS5). In normal operation this bit will be = 0. Bit 6: Frame Alignment Signal Bit 6 (FAS6). In normal operation this bit will be = 0. Bit 7: International Bit (Si) 77 of 129 DS26504 T1/E1/J1/64KCC BITS Element Register Name: Register Description: Register Address: RNAF Receive Non-Align Frame Register 57h Bit # Name Default HW Mode 7 Si 0 6 1 0 5 A 0 4 Sa4 0 3 Sa5 0 2 Sa6 0 1 Sa7 0 0 Sa8 0 X X X X X X X X Bit 0: Additional Bit 8 (Sa8) Bit 1: Additional Bit 7 (Sa7) Bit 2: Additional Bit 6 (Sa6) Bit 3: Additional Bit 5 (Sa5) Bit 4: Additional Bit 4 (Sa4) Bit 5: Remote Alarm (A) Bit 6: Frame Nonalignment Signal Bit (1). In normal operation this bit will be = 1. Bit 7: International Bit (Si) Register Name: Register Description: Register Address: TAF Transmit Align Frame Register 40h Bit # Name Default HW Mode 7 Si 0 6 0 0 5 0 0 4 1 1 3 1 1 2 0 0 1 1 1 0 1 1 0 0 0 1 1 0 1 1 Bit 0: Frame Alignment Signal Bit (1) Bit 1: Frame Alignment Signal Bit (1) Bit 2: Frame Alignment Signal Bit (0) Bit 3: Frame Alignment Signal Bit (1) Bit 4: Frame Alignment Signal Bit (1) Bit 5: Frame Alignment Signal Bit (0) Bit 6: Frame Alignment Signal Bit (0) Bit 7: International Bit (Si) 78 of 129 DS26504 T1/E1/J1/64KCC BITS Element Register Name: Register Description: Register Address: TNAF Transmit Non-Align Frame Register 41h Bit # Name Default 6 1 1 7 Si 0 5 A 0 4 Sa4 0 3 Sa5 0 Bit 0: Additional Bit 8 (Sa8) Bit 1: Additional Bit 7 (Sa7) Bit 2: Additional Bit 6 (Sa6) Bit 3: Additional Bit 5 (Sa5) Bit 4: Additional Bit 4 (Sa4) Bit 5: Remote Alarm (used to transmit the alarm A) Bit 6: Frame Nonalignment Signal Bit (1) Bit 7: International Bit (Si) 79 of 129 2 Sa6 0 1 Sa7 0 0 Sa8 0 DS26504 T1/E1/J1/64KCC BITS Element 13. LINE INTERFACE UNIT (LIU) The LIU in the DS26504 contains three sections: the receiver, which handles clock and data recovery; the transmitter, which generates waveshapes and drives the network line; and the jitter attenuator. These three sections are controlled by the line interface control registers (LIC1–LIC4), which are described below. The DS26504 can switch among T1, J1, E1, and 6312kHz without changing any external circuits. A different transformer is used for 64KCC networks. For a list of recommended transformer part numbers, go to www.maxim-ic.com/support. Figure 13-1 shows a network connection using minimal components. In this configuration the DS26504, using a fixed 120Ω external termination, can connect to T1, J1, E1, 64KCC, or 6312kHz. The receiver can adjust the 120Ω termination to 100Ω, 110Ω, or 75Ω. The transmitter can adjust its output impedance to provide high return loss characteristics for 75Ω, 100Ω, 110Ω, and 120Ω lines. Other components may be added to this configuration to meet safety and network protection requirements. This is covered in the Recommended Circuits section (Section 13.8). Figure 13-1. Basic Network Connection TTIP 10μF TRANSMIT LINE BACKPLANE CONNECTIONS TRING 2:1 DS26504 RTIP RECEIVE LINE RRING 1:1 60Ω 60Ω 0.01μF 80 of 129 DS26504 T1/E1/J1/64KCC BITS Element 13.1 LIU Operation The LIU interfaces the T1, E1, 64KCC, and 6312kHz signals to the various types of network media through coupling transformers. The LIU transmit and receive functions are independent. For example, the receiver can be in T1 mode while the transmitter is in E1 mode. The 6312kHz transmission is an exception to the other modes. For transmission, 6312kHz is only available as a 0 to 3.3V signal on the TCLKO pin. It is not output to the TTIP and TRING pins for coupling to twisted pair. Because the G.703 specifications of the transmit pulse shape for Japanese 6312kHz are unclear, the user can externally filter this signal to generate a sine-wave type of signal. However, on the receive side, 6312kHz can be input through the receive transformer to the RTIP and RRING pins. 13.2 LIU Receiver The analog AMI/HDB3 E1 waveform, AMI/B8ZS T1 waveform, or AMI 64KCC waveform is transformer-coupled into the RTIP and RRING pins of the DS26504. The user has the option to use internal termination, software-selectable for 75/100/110/120Ω applications, or external termination. The LIU recovers clock and data from the analog signal and passes it through the jitter attenuation mux. (Note: The jitter attenuator is only available in T1 or E1 mode.) The DS26504 contains an active filter that reconstructs the analog-received signal for the nonlinear losses that occur in long-haul T1 and E1 transmission. The receiver is configurable for various T1 and E1 monitor applications. The device has a usable receive sensitivity of 0dB to –43dB for E1 and 0dB to –36dB for T1, which allows the device to operate on 0.63mm (22AWG) cables up to 2.5km (E1) and 6000ft (T1) in length. The DS26504’s LIU is designed to be fully software selectable for E1 and T1 without the need to change any external resistors for the receive-side. The receiver will allow the user to configure the DS26504 for 75Ω, 100Ω, 110Ω, 120Ω, or 133Ω receive termination by setting the RT0(LIC4.0), RT1(LIC4.1), and RT2(LIC4.2). When using the internal termination feature, the resistors labeled R in Figure 13-4 should be 60Ω each. If external termination is used, RT0, RT1, and RT2 should be set to zero and the resistors labeled R in Figure 13-4 need to be 37.5Ω, 50Ω, 55Ω, 60Ω, or 66.5Ω each, depending on the required termination. There are two ranges of receive sensitivity for T1 and E1, which is selectable by the user. The EGL bit of LIC1 (LIC1.4) selects the full or limited sensitivity. Normally, the clock that is output at the RCLK pin is the recovered clock from the waveform presented at the RTIP and RRING inputs. If the jitter attenuator is placed in the receive path (as is the case in most applications), the jitter attenuator restores the RCLK to an approximate 50% duty cycle. If the jitter attenuator is either placed in the transmit path or is disabled, the RCLK output can exhibit slightly shorter high cycles of the clock. This is due to the highly over-sampled digital clock-recovery circuitry. See the Receive AC Timing Characteristics section for more details. When no signal is present at RTIP and RRING, a receive loss-of-signal (RLOS) condition will occur and the signal at RCLK will be derived from the scaled signal present on the MCLK pin. 13.2.1 Receive Level Indicator The DS26504 reports the signal strength at RTIP and RRING in 2.5dB increments via RL3–RL0 located in the Information Register 1 (INFO1). This feature is helpful when trouble-shooting line performance problems. 81 of 129 DS26504 T1/E1/J1/64KCC BITS Element 13.2.2 Receive G.703 Section 13 Synchronization Signal The DS26504 can receive a 2.048MHz square-wave synchronization clock as specified in Section 13 of ITU G.703. To use the DS26504 in this mode, set the mode configuration bits in the Mode Configuration Register (MCREG). 13.2.3 Monitor Mode Monitor applications in both E1 and T1 require various flat-gain settings for the receive-side circuitry. The DS26504 can be programmed to support these applications via the monitor mode control bits MM1 and MM0 in the LIC3 register. Figure 13-2. Typical Monitor Application PRIMARY T1/E1 TERMINATING DEVICE T1/E1 LINE Rm Rm MONITOR PORT JACK X F M R Rt DS26504 SECONDARY T1/E1 TERMINATING DEVICE 13.3 LIU Transmitter The DS26504 uses a phase-lock loop along with a precision digital-to-analog converter (DAC) to create the waveforms that are transmitted onto the E1 or T1 line. The waveforms created by the DS26504 meet the latest ETSI, ITU, ANSI, and AT&T specifications. The waveform that is to be generated is set by the transmit mode bits (TMODE[3:0]) in the MCREG register, as well as the L2/L1/L0 bits in register LIC1 if applicable. ITU specification G.703 requires an accuracy of ±50ppm for both T1 and E1. TR62411 and ANSI specs require an accuracy of ±32ppm for T1 interfaces. The transmit clock can be sourced from the recovered clock (RCLK), the pre-scaled MCLK, the TCLK pin, or the TX PLL. See the TX PLL clock mux diagram in Figure 3-3. Due to the nature of the design of the transmitter in the DS26504, very little jitter (less than 0.005UIP-P broadband from 10Hz to 100kHz) is added to the jitter present on the selected transmit clock source. Also, the waveforms created are independent of the duty cycle of TCLK. The transmitter in the DS26504 couples to the transmit twisted pair (or coaxial cable in some applications) via a 1:2 step-up transformer. For the device to create the proper waveforms, the transformer used must meet the specifications listed in Table 13-3. The DS26504 has the option of using software-selectable transmit termination. 82 of 129 DS26504 T1/E1/J1/64KCC BITS Element The transmit line drive has two modes of operation: fixed gain or automatic gain. In the fixed gain mode, the transmitter outputs a fixed current into the network load to achieve a nominal pulse amplitude. In the automatic gain mode, the transmitter adjusts its output level to compensate for slight variances in the network load. See the Transmit Line Build-Out Control (TLBC) register for details. 13.3.1 Transmit Short-Circuit Detector/Limiter The DS26504 has an automatic short-circuit limiter that limits the source current to approximately 50mA (RMS) on the network side of the transformer in E1 modes of operations and 70mA (RMS) on the network side of the transformer in T1 modes of operation. These values are approximate and are not guaranteed by production testing. This feature can be disabled by setting the SCLD bit (LIC2.1) = 1. TCLE (SR1.2) provides a real-time indication of when the current limiter is activated. If the current limiter is disabled, TCLE will indicate that a short-circuit condition exists. Status Register SR1.2 provides a latched version of the information, which can be used to activate an interrupt when enable via the IMR1 register. When set low, the TPD bit (LIC1.0) will power-down the transmit line driver and three-state the TTIP and TRING pins. 13.3.2 Transmit Open-Circuit Detector The DS26504 can also detect when the TTIP or TRING outputs are open circuited. TOCD (SR1.1) will provide a real-time indication of when an open circuit is detected. SR1 provides a latched version of the information (SR1.1), which can be used to activate an interrupt when enabled via the IMR1 register. The functionality of these bits is not guaranteed by production testing. 13.3.3 Transmit BPV Error Insertion When IBPV (LIC2.5) is transitioned from a zero to a one, the device waits for the next occurrence of three consecutive ones to insert a BPV. IBPV must be cleared and set again for another BPV error insertion. 13.3.4 Transmit G.703 Section 13 Synchronization Signal (E1 Mode) The DS26504 can transmit the 2.048MHz square-wave synchronization clock. To transmit the 2.048MHz clock, when in E1 mode, set the mode configuration bits in the Mode Configuration Register (MCREG). 13.4 MCLK Pre-Scaler A 2.048MHz x 2N (where N = 0 to 3), 1.544MHz x 2N (where N = 0 to 3), or 12.8MHz (available in CPU interface mode only) clock must be applied to MCLK. A pre-scaler (divide by 2, 4, or 8) and PLLs are selected to product an internal 2.048MHz or 1.544MHz clock. ITU specification G.703 requires an accuracy of ±50ppm for both T1 and E1. TR62411 and ANSI specs require an accuracy of ±32ppm for T1 interfaces. A pre-scaler divides the 16.384MHz, 12.8MHz, 8.192MHz, or 4.096MHz clock down to 2.048MHz. An on-board PLL for the jitter attenuator converts the 2.048MHz clock to a 1.544MHz rate for T1 applications. Setting JACKS0 (LIC2.3) to logic 0 bypasses this PLL. 13.5 Jitter Attenuator The DS26504’s jitter attenuator can be set to a depth of either 32 bits or 128 bits via the JABDS bit (LIC1.2). The 128-bit mode is used in applications where large excursions of wander are expected. The 32-bit mode is used in delay-sensitive applications. The characteristics of the attenuation are shown in Figure 13-10 and Figure 13-11. The jitter attenuator can be placed in either the receive path or the transmit path by appropriately setting or clearing the JAS bit (LIC1.3). The jitter attenuator can also be disabled (in effect, removed) by setting the DJA bit (LIC1.1). Either the recovered clock from the 83 of 129 DS26504 T1/E1/J1/64KCC BITS Element clock/data recovery block or the clock applied at the TCLK pin is adjusted to create a smooth jitter-free clock that is used to clock data out of the jitter attenuator FIFO. It is acceptable to provide a gapped/bursty clock at the TCLK pin if the jitter attenuator is placed on the transmit side. If the incoming jitter exceeds either 120UIP-P (buffer depth is 128 bits) or 28UIP-P (buffer depth is 32 bits), then the DS26504 will divide the internal nominal 32.768MHz (E1) or 24.704MHz (T1) clock by either 15 or 17 instead of the normal 16 to keep the buffer from overflowing. When the device divides by either 15 or 17, it also sets the Jitter Attenuator Limit Trip (JALT) bit in Status Register 1 (SR1.4). 13.6 CMI (Code Mark Inversion) Option The DS26504 provides a CMI interface for connection to optical transports. This interface is a unipolar 1T2B type of signal. Ones are encoded as either a logical one or zero level for the full duration of the clock period. Zeros are encoded as a zero-to-one transition at the middle of the clock period. Figure 13-3. CMI Coding CLOCK DATA 1 1 0 1 0 0 1 CMI Transmit and receive CMI is enabled via LIC4.7. When this register bit is set, the TTIP pin outputs CMIcoded data at normal levels. This signal can be used to directly drive an optical interface. When CMI is enabled, the user can also use HDB3/B8ZS coding. When this register bit is set, the RTIP pin becomes a unipolar CMI input. The CMI signal is processed to extract and align the clock with data. 84 of 129 DS26504 T1/E1/J1/64KCC BITS Element 13.7 LIU Control Registers Register Name: Register Description: Register Address: Bit # Name Default HW Mode 7 L2 0 L2 PIN 13 LIC1 Line Interface Control 1 30h 6 L1 0 L1 PIN 12 5 L0 0 L0 PIN 11 4 EGL 0 3 JAS 0 2 JABDS 0 1 DJA 0 0 TPD 0 0 0 0 0 1 Bit 0: Transmit Power-Down (TPD) 0 = powers down the transmitter and three-states the TTIP and TRING pins 1 = normal transmitter operation Bit 1: Disable Jitter Attenuator (DJA) 0 = jitter attenuator enabled 1 = jitter attenuator disabled Bit 2/Jitter Attenuator Buffer Depth Select (JABDS) 0 = 128 bits 1 = 32 bits (use for delay-sensitive applications) Bit 3: Jitter Attenuator Select (JAS) 0 = place the jitter attenuator on the receive side 1 = place the jitter attenuator on the transmit side Bit 4: Receive Equalizer Gain Limit (EGL). This bit controls the sensitivity of the receive equalizer. T1 Mode: 0 = -36dB (long haul) 1 = -15dB (limited long haul) E1 Mode: 0 = -43dB (long haul) 1 = -12dB (short haul) Bits 5, 6, 7: Line Build-Out Select (L0 to L2). When using the internal termination, the user needs only to select 000 for 75Ω operation or 001 for 120Ω operation. This selects the proper voltage levels for 75Ω or 120Ω operation. Using TT0, TT1, and TT2 of the LICR4 register, users can then select the proper internal source termination. Line build-outs 100 and 101 are for backwards compatibility with older products only. E1 Mode L2 L1 0 0 0 0 1 0 1 0 L0 0 1 0 1 APPLICATION 75Ω normal 120Ω normal 75Ω with high return loss (Note 2) 120Ω with high return loss (Note 2) N (Note 1) 1:2 1:2 1:2 1:2 N.M. = Not meaningful Note 1: Transformer turns ratio. Note 2: TT0, TT1, and TT2 of the LIC4 register must be set to zero in this configuration. 85 of 129 RETURN LOSS N.M. N.M. 21dB 21dB Rt (Note 1) 0 0 6.2Ω 11.6Ω DS26504 T1/E1/J1/64KCC BITS Element T1 Mode L2 L1 0 0 0 0 0 1 0 1 1 0 1 0 1 1 1 1 L0 0 1 0 1 0 1 0 1 APPLICATION DSX-1 (0 to 133 feet)/0dB CSU DSX-1 (133 to 266 feet) DSX-1 (266 to 399 feet) DSX-1 (399 to 533 feet) DSX-1 (533 to 655 feet) Reserved Reserved Reserved N (Note 1) 1:2 1:2 1:2 1:2 1:2 — — — RETURN LOSS N.M. N.M. N.M. N.M. N.M. — — — Rt (Note 1) 0 0 0 0 0 — — — N.M. = Not meaningful Note 1: Transformer turns ratio. Register Name: Register Description: Register Address: Bit # Name Default HW Mode TLBC Transmit Line Build-Out Control 34h 7 — 0 6 AGCE 0 5 GC5 0 4 GC4 0 3 GC3 0 2 GC2 0 1 GC1 0 0 GC0 0 0 0 0 0 0 0 0 0 Bits 0 to 5: Gain Control Bits 0 to 5 (GC0 toGC5). The GC0 through GC5 bits control the gain setting for the nonautomatic gain mode. Use the tables below for setting the recommended values. The LBO (line build-out) column refers to the value in the L0–L2 bits in LIC1 (Line Interface Control 1) register. NETWORK MODE T1, Impedance Match Off T1, Impedance Match On E1, Impedance Match Off E1, Impedance Match On LBO 0 1 2 3 4 5 6 7 0 1 2 3 4 5 6 7 0 1 4 5 0 1 GC5 1 0 0 1 1 1 0 1 0 0 0 0 1 1 0 1 1 1 1 1 0 0 GC4 0 1 1 0 0 0 1 1 1 1 1 1 0 0 0 1 0 0 0 0 1 1 GC3 0 1 1 0 0 0 0 1 1 0 0 1 0 0 1 1 0 0 1 1 1 1 GC2 1 0 0 0 1 1 0 1 1 1 1 0 0 0 1 1 0 0 0 0 0 0 Bit 6: Automatic Gain Control Enable (AGCE) 0 = use Transmit AGC, TLBC bits 0–5 are “don’t care” 1 = do not use Transmit AGC, TLBC bits 0–5 set nominal level Bit 7: Unused, must be set = 0 for proper operation. 86 of 129 GC1 1 1 1 0 1 1 1 1 1 0 0 1 1 0 0 1 0 0 1 0 1 1 GC0 0 1 0 0 1 1 1 1 0 1 1 0 0 0 0 1 1 1 0 0 0 0 DS26504 T1/E1/J1/64KCC BITS Element Register Name: Register Description: Register Address: Bit # Name Default HW Mode LIC2 Line Interface Control 2 31h 7 JACKS1 0 6 LIRST 0 5 IBPV 0 0 0 0 4 TAIS 0 TAIS PIN 10 3 JACKS0 0 JACKS0 PIN 46 2 RCCFE 0 1 SCLD 0 0 CLDS 0 0 0 0 Bit 0: Custom Line-Driver Select (CLDS). Setting this bit to a one redefines the operation of the transmit line driver. When this bit is set to a one and LIC1.5 = LIC1.6 = LIC1.7 = 0, the device generates a square wave at the TTIP and TRING outputs instead of a normal waveform. When this bit is set to a one and LIC1.5 = LIC1.6 = LIC1.7 ≠ 0, the device forces TTIP and TRING outputs to become open-drain drivers instead of their normal push-pull operation. This bit should be set to zero for normal operation of the device. Bit 1: Short Circuit Limit Disable (in E1 mode) (SCLD). Controls the 50mA (RMS) current limiter. 0 = enable 50mA current limiter 1 = disable 50mA current limiter Bit 2: Receive Composite Clock Filter Enable (RCCFE) (64KCC mode only). Setting this bit enables the PLL filter on the received 64kHz composite clock. Note: The 8kHz and 400Hz output are not filtered. 0 = Receive Composite Clock Filter disabled 1 = Receive Composite Clock Filter enabled Bit 3: Jitter Attenuator Clock Select 0 (JACKS0). This bit, along with JACKS1 (LIC2.7), MPS0 (LIC4.6), and MPS1 (LIC4.7), controls the source for JA CLOCK from the MCLK pin. Note: This bit must be configured even if the jitter attenuator is disabled. The clock and data recovery engine also uses the JA CLOCK. Setting this bit enables the 2.048MHz to 1.544MHz conversion PLL for T1 applications. See the table in the LIC4 register description for more details on setting up the JA CLOCK source. 0 = 2.048MHz to 1.544MHz PLL bypassed 1 = 2.048MHz to 1.544MHz PLL enabled Bit 4: Transmit Alarm Indication Signal (TAIS). In T1, E1, or J1 modes, this bit causes an all-ones pattern to be transmitted. 0 = transmit an unframed all-ones code 1 = transmit data normally In all 64KCC modes, this bit disables the BPV-encoded sub-rates. 0 = transmit all ones without BPVs 1 = transmit normal 64KCC Bit 5: Insert BPV (IBPV). A zero-to-one transition on this bit causes a single BPV to be inserted into the transmit data stream. Once this bit has been toggled from a zero to a one, the device waits for the next occurrence of three consecutive ones to insert the BPV. This bit must be cleared and set again for a subsequent error to be inserted. Bit 6: Line Interface Reset (LIRST). Setting this bit from a zero to a one initiates an internal reset that resets the clock recovery state machine and recenters the jitter attenuator. Normally this bit is only toggled on power-up. Must be cleared and set again for a subsequent reset. Bit 7: Jitter Attenuator Clock Select 1 (JACKS1). This bit, along with JACKS0 (LIC2.3), MPS0 (LIC4.6), and MPS1 (LIC4.7), controls the source for JA CLOCK from the MCLK pin. Note: This bit must be configured even if the jitter attenuator is disabled. The clock and data recovery engine also uses the JA CLOCK. Setting this bit enables the 12.8MHz to 2.048MHz conversion PLL. See the table in the LIC4 register description for more details on setting up the JA CLOCK source. 0 = 12.8MHz to 2.048MHz PLL bypassed 1 = 12.8MHz to 2.048MHz PLL enabled 87 of 129 DS26504 T1/E1/J1/64KCC BITS Element Register Name: Register Description: Register Address: Bit # Name Default HW Mode LIC3 Line Interface Control 3 32h 7 CMIE 0 6 CMII 0 5 EX133 0 4 MM1 0 3 MM0 0 2 — 0 1 — 0 0 TAOZ 0 0 0 0 0 0 0 0 0 Bit 0: Transmit Alternate Ones and Zeros (TAOZ). Transmit a …101010… pattern at TTIP and TRING. 0 = disabled 1 = enabled Bits 1 and 2: Unused, must be set = 0 for proper operation. Bits 3 and 4: Monitor Mode (MM0 and MM1). Note: This function is only available in T1 or E1 mode. MM1 0 0 1 1 MM0 0 1 0 1 INTERNAL LINEAR GAIN BOOST (dB) Normal operation (no boost) 20 26 32 Bit 5: Eternal 133Ω Resistor Select (EX133). This bit is used to indicate to the device’s internal receive termination control circuitry that either a 120Ω or 133Ω external resistor is used. Used in conjunction with the RT0, RT1, and RT2 bits in the LIC4 register. Note: A fixed 133Ω external resistor allows the internal termination to create all other termination values. A fixed 120Ω external resistor allows the internal termination to create all other termination values except 133Ω. 0 = indicates a 120Ω external resistor is connected 1 = indicates a 133Ω external resistor is connected Bit 6: CMI Invert (CMII) 0 = CMI normal at TTIP and RTIP 1 = invert CMI signal at TTIP and RTIP Bit 7: CMI Enable (CMIE) 0 = disable CMI mode 1 = enable CMI mode 88 of 129 DS26504 T1/E1/J1/64KCC BITS Element Register Name: Register Description: Register Address: Bit # Name Default HW Mode 7 MPS1 0 MPS1 PIN 16 LIC4 Line Interface Control 4 33h 6 MPS0 0 MPS0 PIN 15 5 TT2 0 4 TT1 0 3 TT0 0 2 RT2 0 1 RT1 0 0 RT0 0 — — — — — — Bits 0 to 2: Receive Termination Select (RT0 to RT2) EX133 EXTERNAL RT2 RT1 RT0 (LIC3.5) RESISTOR VALUE 0 0 0 X — 0 0 1 0 120Ω 0 0 1 1 133Ω 0 1 0 0 120Ω 0 1 0 1 133Ω 0 1 1 0 120Ω 0 1 1 1 133Ω 1 0 0 0 120Ω 1 0 0 1 133Ω 1 0 1 1 133Ω 1 1 0 X — 1 1 1 X — RECEIVE TERMINATION External Resistor Value 75Ω 75Ω 100Ω 100Ω 120Ω (External Resistor Value) 120Ω 110Ω 110Ω 133Ω (External Resistor Value) External Resistor Value External Resistor Value Note: A fixed 133Ω external resistor allows the internal termination to create all other termination values. A fixed 120Ω external resistor allows the internal termination to create all other termination values except 133Ω. Bits 3, 4, 5: Transmit Termination Select (TT0 to TT2) INTERNAL TRANSMIT TT2 TT1 TT0 TERMINATION CONFIGURATION 0 0 0 Termination Disabled 0 0 1 75Ω Enabled 0 1 0 100Ω Enabled 0 1 1 120Ω Enabled 1 0 0 110Ω Enabled 1 0 1 133Ω Enabled 1 1 0 Disabled 1 1 1 Disabled Bits 6 and 7: MCLK Prescaler (MPS0 and MPS1) (T1 Mode) JACKS0 MCLK MPS1 MPS0 (LIC2.3) (MHz) 1.544 0 0 0 3.088 0 1 0 6.176 1 0 0 12.352 1 1 0 12.80 0 0 1 2.048 0 0 1 4.096 0 1 1 8.192 1 0 1 16.384 1 1 1 89 of 129 JACKS1 (LIC2.7) 0 0 0 0 1 0 0 0 0 DS26504 T1/E1/J1/64KCC BITS Element Bits 6 and 7: MCLK Prescaler (MPS0 and MPS1) (E1 Mode) MCLK JACKS0 MPS1 MPS0 (MHz) (LIC2.3) 2.048 0 0 0 4.096 0 1 0 8.192 1 0 0 12.8 0 0 0 16.384 1 1 0 JACKS1 (LIC2.7) 0 0 0 1 0 Register Name: Register Description: Register Address: INFO1 Information Register 1 11h Bit # Name Default HW Mode 7 — 0 6 — 0 5 — 0 4 — 0 3 RL3 0 2 RL2 0 1 RL1 0 0 RL0 0 X X X X X X X X Bits 0 to 3: Receive Level Bits (RL0 to RL3). Real-time bits. RL3 0 0 0 0 0 0 0 0 1 1 1 1 1 1 1 1 RL2 0 0 0 0 1 1 1 1 0 0 0 0 1 1 1 1 RL1 0 0 1 1 0 0 1 1 0 0 1 1 0 0 1 1 RL0 0 1 0 1 0 1 0 1 0 1 0 1 0 1 0 1 RECEIVE LEVEL (dB) Greater than -2.5 -2.5 to -5.0 -5.0 to -7.5 -7.5 to -10.0 -10.0 to -12.5 -12.5 to -15.0 -15.0 to -17.5 -17.5 to -20.0 -20.0 to -22.5 -22.5 to -25.0 -25.0 to -27.5 -27.5 to -30.0 -30.0 to –32.5 -32.5 to -35.0 -35.0 to -37.5 Less than -37.5 Bits 4 to 7: Unused 90 of 129 DS26504 T1/E1/J1/64KCC BITS Element Register Name: Register Description: Register Address: SR1 Status Register 1 14h Bit # Name Default HW Mode 7 — 0 6 — 0 5 — 0 4 JALT 0 3 — 0 2 TCLE 0 1 TOCD 0 0 — 0 X X X X X X X X Bits 0, 3, 5, 6, 7: Unused, must be set = 0 for proper operation. Bit 1: Transmit Open-Circuit-Detect Condition (TOCD). Set when the device detects that the TTIP and TRING outputs are open-circuited. Note: This function is not support in transmit 6312kHz mode and is not guaranteed by production testing. Bit 2: Transmit Current-Limit-Exceeded Condition (TCLE). Set when the current limiter is activated whether the current limiter is enabled or not. This is set at approximately 50mA (RMS) on the network side of the transformer in E1 operating modes and 70mA (RMS) on the network side of the transformer in T1 operating modes. These values are approximate and are not guaranteed by production testing. Note: This function is not supported in transmit CMI, 64kHz, or 6312kHz mode. Bit 4: Jitter Attenuator Limit Trip Event (JALT). Set when the jitter attenuator FIFO reaches to within 4 bits of its useful limit. This bit is cleared when read. Useful for debugging jitter-attenuation operation. 91 of 129 DS26504 T1/E1/J1/64KCC BITS Element Register Name: Register Description: Register Address: IMR1 Interrupt Mask Register 1 15h Bit # Name Default HW Mode 7 — 0 6 — 0 5 — 0 4 JALT 0 3 — 0 2 TCLE 0 1 TOCD 0 0 — 0 X X X X X X X X Bits 0, 3, 5, 6, 7: Unused, must be set = 0 for proper operation. Bit 1: Transmit Open-Circuit-Detect Condition (TOCD) 0 = interrupt masked 1 = interrupt enabled–generates interrupts on rising and falling edges Bit 2: Transmit Current-Limit-Exceeded Condition (TCLE) 0 = interrupt masked 1 = interrupt enabled–generates interrupts on rising and falling edges Bit 4: Jitter Attenuator Limit Trip Event (JALT) 0 = interrupt masked 1 = interrupt enabled 92 of 129 DS26504 T1/E1/J1/64KCC BITS Element 13.8 Recommended Circuits Figure 13-4. Software-Selected Termination, Metallic Protection 3.3 V 10uF T1 F1 TX TIP T3 DVDD TTIP 0.01 uF S1 S3 TRING TX RING 2:1 DS26504 68 uF 3.3 V T2 F2 RX TIP RTIP T4 TVDD 0.1 uF TVSS S2 S4 RVDD RX RING RRING 1:1 60 0.1 uF RVSS 60 0.1 uF Table 13-1. Component List (Software-Selected Termination, Metallic Protection) NAME F1 and F2 S1 and S2 S3 andS4 T1 and T2 T3 and T4 Note 1: Note 2: Note 3: Note 4: 0.1 uF DVSS DESCRIPTION 1.25A slow blow fuse 25V (max) transient suppressor 77V (max) transient suppressor Transformer 1:1CT and 1:136CT (5.0V, SMT) (Note 1) Transformer 1:1CT and 1:2CT (3.3V, SMT) (Note 1) Dual common-mode choke (SMT) T3 and T4 are optional. For more information, contact the Telecom Support Group at www.maxim-ic.com/support. The layout from the transformers to the network interface is critical. Traces should be at least 25 mils wide and separated from other circuit lines by at least 150 mils. The area under this portion of the circuit should not contain power planes. Some T1 (never in E1) applications source or sink power from the network-side center taps of the Rx/Tx transformers. A list of transformer part numbers and manufacturers is available by contacting www.maxim-ic.com/support. 93 of 129 DS26504 T1/E1/J1/64KCC BITS Element Figure 13-5. Software-Selected Termination, Longitudinal Protection F1 TX TIP 3.3 V 10uF T1 T3 DVDD TTIP S3 0.01 uF S1 0.1 uF DVSS S7 S4 TX RING TRING 2:1 F2 DS26504 68 uF 3.3 V F3 RX TIP T2 RTIP T4 S5 RVDD S6 RX RING RRING F4 0.1 uF TVSS S2 S8 TVDD 1:1 60 0.1 uF RVSS 60 0.1 uF Table 13-2. Component List (Software-Selected Termination, Longitudinal Protection) NAME F1 to F4 S1 and S2 S3, S4, S5, S6 S7 and S8 T1 and T2 T3 and T4 DESCRIPTION 1.25A slow blow fuse 25V (max) transient suppressor (Note 1) 180V (max) transient suppressor (Note 1) 40V (max) transient suppressor Transformer 1:1CT and 1:136CT (5.0V, SMT) (Note 2) Transformer 1:1CT and 1:2CT (3.3V, SMT) (Note 2) Dual common-mode choke (SMT) Note 1: T3 and T4 are optional. For more information, contact the Telecom Support Group at www.maxim-ic.com/support. Note 2: A list of alternate transformer part numbers and manufacturers is available at www.maxim-ic.com/support. Note 3: The layout from the transformers to the network interface is critical. Traces should be at least 25 mils wide and separated from other circuit lines by at least 150 mils. The area under this portion of the circuit should not contain power planes. Some T1 (never in E1) applications source or sink power from the network-side center taps of the Rx/Tx transformers. The ground trace connected to the S2/S3 pair and the S4/S5 pair should be at least 50 mils wide to conduct the extra current from a longitudinal power-cross event. Note 4: Note 5: 94 of 129 DS26504 T1/E1/J1/64KCC BITS Element 13.9 Component Specifications Table 13-3. Transformer Specifications SPECIFICATION Turns Ratio 3.3V Applications Primary Inductance Leakage Inductance Intertwining Capacitance Transmit Transformer DC Resistance Primary (Device Side) Secondary Receive Transformer DC Resistance Primary (Device Side) Secondary RECOMMENDED VALUE 1:1 (receive) and 1:2 (transmit) ±2% 600μH minimum 1.0μH maximum 40pF maximum 1.0Ω maximum 2.0Ω maximum 1.2Ω maximum 1.2Ω maximum 95 of 129 DS26504 T1/E1/J1/64KCC BITS Element Figure 13-6. E1 Transmit Pulse Template 1.2 1.1 269ns SCALED AMPLITUDE (in 75 ohm systems, 1.0 on the scale = 2.37Vpeak in 120 ohm systems, 1.0 on the scale = 3.00Vpeak) 1.0 0.9 0.8 0.7 G.703 Template 194ns 0.6 0.5 219ns 0.4 0.3 0.2 0.1 0 -0.1 -0.2 -250 -200 -150 -100 -50 0 50 100 150 200 250 TIME (ns) Figure 13-7. T1 Transmit Pulse Template 1.2 1.0 -0.77 -0.39 -0.27 -0.27 -0.12 0.00 0.27 0.35 0.93 1.16 0.9 0.8 0.7 NORMALIZED AMPLITUDE MINIMUM CURVE UI Time Amp. MAXIMUM CURVE UI Time Amp. 1.1 0.6 -500 -255 -175 -175 -75 0 175 225 600 750 0.05 0.05 0.80 1.15 1.15 1.05 1.05 -0.07 0.05 0.05 0.5 -0.77 -0.23 -0.23 -0.15 0.00 0.15 0.23 0.23 0.46 0.66 0.93 1.16 -500 -150 -150 -100 0 100 150 150 300 430 600 750 -0.05 -0.05 0.50 0.95 0.95 0.90 0.50 -0.45 -0.45 -0.20 -0.05 -0.05 0.4 0.3 0.2 0.1 0 -0.1 -0.2 -0.3 T1.102/87, T1.403, CB 119 (Oct. 79), & I.431 Template -0.4 -0.5 -500 -400 -300 -200 -100 0 100 200 TIME (ns) 96 of 129 300 400 500 600 700 DS26504 T1/E1/J1/64KCC BITS Element Figure 13-8. Jitter Tolerance (T1 Mode) 1K UNIT INTERVALS (UIpp) DS26504 DS26502 TOLERANCE Tolerance 100 TR 62411 (Dec. 90) 10 ITU-T G.823 1 0.1 1 10 100 1K 10K 100K FREQUENCY (Hz) Figure 13-9. Jitter Tolerance (E1 Mode) UNIT INTERVALS (UIpp) 1k DS26504 DS26502 TOLERANCE Tolerance 100 40 10 1.5 1 0.1 Minimum Tolerance Level as per ITU G.823 1 10 20 100 1k FREQUENCY (Hz) 97 of 129 0.2 2.4k 10k 18k 100k DS26504 T1/E1/J1/64KCC BITS Element Figure 13-10. Jitter Attenuation (T1 Mode) -20dB C ve ur A TR 62411 (Dec. 90) Prohibited Area -40dB rve Cu JITTER ATTENUATION (dB) 0dB B DS26502 DS26504 T1 T1MODE MODE -60dB 1 10 100 1K FREQUENCY (Hz) 10K 100K JITTER ATTENUATION (dB) Figure 13-11. Jitter Attenuation (E1 Mode) 0dB ITU G.7XX Prohibited Area TBR12 Prohibited Area -20dB DS26502 DS26504 E1 E1MODE MODE -40dB -60dB 1 10 100 1K FREQUENCY (Hz) 98 of 129 10K 100K DS26504 T1/E1/J1/64KCC BITS Element 14. LOOPBACK CONFIGURATION Register Name: Register Description: Register Address: LBCR Loopback Control Register 20h Bit # Name Default HW Mode 7 — 0 6 — 0 5 — 0 4 — 0 3 LLB 0 0 0 0 0 0 2 RLB 0 RLB PIN 60 1 — 0 0 — 0 0 0 Bits 0, 1, 4 to 7: Unused, must be set = 0 for proper operation. Bit 2: Remote Loopback (RLB). In this loopback, data received at RTIP and RRING will be looped back to the transmit LIU. Received data will continue to pass through the receive side framer of the DS26504 as it would normally and the data from the transmit side formatter will be ignored. 0 = loopback disabled 1 = loopback enabled Bit 3: Local Loopback (LLB). In this loopback, data will continue to be transmitted as normal through the transmit side of the DS26504. Data being received at RTIP and RRING will be replaced with the data being transmitted. Data in this loopback will pass through the jitter attenuator if enabled. 0 = loopback disabled 1 = loopback enabled 99 of 129 DS26504 T1/E1/J1/64KCC BITS Element 15. 64KHZ SYNCHRONIZATION INTERFACE The 64kHz synchronization interface conforms to Appendix II of G.703. It consists of a composite clock, where a 64kHz clock signal is generated or decoded, along with embedded frequencies of 8kHz and 400Hz. Those signals consist of AMI code with an 8kHz bipolar violation removed at every 400Hz. There are two separate modes referred to in the specification, one with both the 64kHz clock and the 8kHz clock, and the second with the 64kHz clock, the 8kHz clock, and the 400Hz clock. Figure 15-1. 64kHz Composite Clock Mode Signal Format No Violation Violation 125 us Violation Violation 125 us No Violation Violation 125 us 125 us 8 kHz 400 Hz 15.1 Receive 64kHz Synchronization Interface Operation In the receive path, the three clock frequencies are decoded from the AMI waveform with bipolar violations that is received at the LIU interface. The 8kHz frequency and the 400Hz frequency are decoded from the presence or absence of bipolar violations as described in G.703. Table 15-1. Specification of 64kHz Clock Signal at Input Port Frequency a) 64kHz + 8kHz, or b) 64kHz + 8kHz + 400Hz Signal format a) AMI with 8kHz bipolar violation, b) AMI with 8kHz bipolar violation removed at every 400Hz Alarm condition Alarm should not be occurred against the amplitude ranged 0.63-1.1 V0-P 100 of 129 DS26504 T1/E1/J1/64KCC BITS Element 15.2 Transmit 64kHz Synchronization Interface Operation In the transmit path, the framer generateS the appropriate AMI waveform with the correct bipolar violations as described by G.703 and GR.378. If an 8kHz signal is present on the TS_8K_4 pin, the bipolar violations are generated synchronously with this signal. If it is absent, the part arbitrarily generates the bipolar violation at an 8kHz frequency. Table 15-2. Specification of 64kHz Clock Signal at Output Port BPV G.703 Level A G.703 Level B G.703 Japanese GR.378 SUBRATES 8kHz 8kHz 8kHz + 400Hz LOAD 110Ω 110Ω 110Ω 8kHz 133Ω PULSE WIDTH ≤ 7.8 ± 0.78μs 9.8 to 10.9μs ≤ 7.8 ± 0.78μs 5/8 period (9.7μs) 101 of 129 AMPLITUDE ≤1V0-P ± 0.1V 3.0V ± 0.5V ≤1 V0-P ± 0.1V 2.7V – 5.5V DS26504 T1/E1/J1/64KCC BITS Element 16. 6312KHZ SYNCHRONIZATION INTERFACE The DS26504 has a 6312kHz Synchronization Interface mode of operation that conforms with Appendix II.2 of G.703, with the exception that the DS26504 transmits a square wave as opposed to the sine wave that is defined in the G.703 specification. 16.1 Receive 6312kHz Synchronization Interface Operation On the receive interface, a 6312kHz sine wave is accepted conforming to the input port requirements of G.703 Appendix II. Alternatively, a 6312kHz square wave will also be accepted. A 6312kHz square wave is output on RCLK in the receive direction. RS_8K and 400Hz are not driven in this mode and will be three-stated. Table 16-1. Specification of 6312kHz Clock Signal at Input Port Frequency 6312kHz Signal format Sinusoidal wave Alarm condition Alarm should not be occurred against the amplitude ranged -16dBm to +3dBm 16.2 Transmit 6312kHz Synchronization Interface Operation On the transmit interface, a nominally 50% duty cycle, 6312kHz square wave at standard logic levels is available from the PLL_OUT pin. In normal operation, the TCLKO pin will output the same signal. However, if remote loopback is enabled then TCLKO will be replaced with the recovered receive clock. See Figure 3-1. The G.703 requirements for the 6312kHz transmitted signal are shown in Table 16-2. The user must provide an external circuit to convert the TCLKO or PLL_OUT signal to the level and impedance required by G.703. The RSER and TS_8K-4 pins are ignored in this mode. TTIP and TRING will be three-stated in this mode. Table 16-2. Specification of 6312kHz Clock Signal Frequency 6312kHz Load impedance 75Ω resistive Transmission media Coaxial pair cable Amplitude 0dBm ± 3dBm 102 of 129 DS26504 T1/E1/J1/64KCC BITS Element 17. JTAG BOUNDARY SCAN ARCHITECTURE AND TEST ACCESS PORT The DS26504 supports the standard IEEE 1149.1 instruction codes SAMPLE/PRELOAD, BYPASS, and EXTEST. Optional public instructions included are HIGHZ, CLAMP, and IDCODE. The DS26504 contains the following as required by IEEE 1149.1 Standard Test Access Port and Boundary Scan Architecture: Test Access Port (TAP) TAP Controller Instruction Register Bypass Register Boundary Scan Register Device Identification Register Details on Boundary Scan Architecture and the Test Access Port can be found in IEEE 1149.1-1990, IEEE 1149.1a-1993, and IEEE 1149.1b-1994. The Test Access Port has the necessary interface pins: JTRST, JTCLK, JTMS, JTDI, and JTDO. See the pin descriptions for details. Figure 17-1. JTAG Functional Block Diagram BOUNDRY SCAN REGISTER IDENTIFICATION REGISTER MUX BYPASS REGISTER INSTRUCTION REGISTER TEST ACCESS PORT CONTROLLER VDD 10kΩ VDD OUTPUT ENABLE VDD 10kΩ JTDI SELECT 10kΩ JTMS JTCLK JTRST 103 of 129 JTDO DS26504 T1/E1/J1/64KCC BITS Element TAP Controller State Machine The TAP controller is a finite state machine that responds to the logic level at JTMS on the rising edge of JTCLK. See Figure 17-2. Test-Logic-Reset Upon power-up, the TAP controller is in the Test-Logic-Reset state. The instruction register contains the IDCODE instruction. All system logic of the device operates normally. Run-Test-Idle The Run-Test-Idle is used between scan operations or during specific tests. The instruction register and test registers remain idle. Select-DR-Scan All test registers retain their previous state. With JTMS LOW, a rising edge of JTCLK moves the controller into the Capture-DR state and initiates a scan sequence. JTMS HIGH during a rising edge on JTCLK moves the controller to the Select-IR-Scan state. Capture-DR Data can be parallel-loaded into the test-data registers selected by the current instruction. If the instruction does not call for a parallel load or the selected register does not allow parallel loads, the test register remains at its current value. On the rising edge of JTCLK, the controller goes to the Shift-DR state if JTMS is LOW, or it goes to the Exit1-DR state if JTMS is HIGH. Shift-DR The test-data register selected by the current instruction is connected between JTDI and JTDO and shifts data one stage toward its serial output on each rising edge of JTCLK. If a test register selected by the current instruction is not placed in the serial path, it maintains its previous state. Exit1-DR While in this state, a rising edge on JTCLK puts the controller in the Update-DR state, which terminates the scanning process, if JTMS is HIGH. A rising edge on JTCLK with JTMS LOW puts the controller in the Pause-DR state. Pause-DR Shifting of the test registers is halted while in this state. All test registers selected by the current instruction retain their previous state. The controller remains in this state while JTMS is LOW. A rising edge on JTCLK with JTMS HIGH puts the controller in the Exit2-DR state. Exit2-DR A rising edge on JTCLK with JTMS HIGH while in this state puts the controller in the Update-DR state and terminates the scanning process. A rising edge on JTCLK with JTMS LOW enters the Shift-DR state. Update-DR A falling edge on JTCLK while in the Update-DR state latches the data from the shift register path of the test registers into the data output latches. This prevents changes at the parallel output due to changes in the shift register. 104 of 129 DS26504 T1/E1/J1/64KCC BITS Element Select-IR-Scan All test registers retain their previous state. The instruction register remains unchanged during this state. With JTMS LOW, a rising edge on JTCLK moves the controller into the Capture-IR state and initiates a scan sequence for the instruction register. JTMS HIGH during a rising edge on JTCLK puts the controller back into the Test-Logic-Reset state. Capture-IR The Capture-IR state is used to load the shift register in the instruction register with a fixed value. This value is loaded on the rising edge of JTCLK. If JTMS is HIGH on the rising edge of JTCLK, the controller enters the Exit1-IR state. If JTMS is LOW on the rising edge of JTCLK, the controller enters the Shift-IR state. Shift-IR In this state, the shift register in the instruction register is connected between JTDI and JTDO and shifts data one stage for every rising edge of JTCLK toward the serial output. The parallel register and all test registers remain at their previous states. A rising edge on JTCLK with JTMS HIGH moves the controller to the Exit1-IR state. A rising edge on JTCLK with JTMS LOW keeps the controller in the Shift-IR state while moving data one stage thorough the instruction shift register. Exit1-IR A rising edge on JTCLK with JTMS LOW puts the controller in the Pause-IR state. If JTMS is HIGH on the rising edge of JTCLK, the controller enters the Update-IR state and terminates the scanning process. Pause-IR Shifting of the instruction shift register is halted temporarily. With JTMS HIGH, a rising edge on JTCLK puts the controller in the Exit2-IR state. The controller remains in the Pause-IR state if JTMS is LOW during a rising edge on JTCLK. Exit2-IR A rising edge on JTCLK with JTMS LOW puts the controller in the Update-IR state. The controller loops back to Shift-IR if JTMS is HIGH during a rising edge of JTCLK in this state. Update-IR The instruction code shifted into the instruction shift register is latched into the parallel output on the falling edge of JTCLK as the controller enters this state. Once latched, this instruction becomes the current instruction. A rising edge on JTCLK with JTMS LOW puts the controller in the Run-Test-Idle state. With JTMS HIGH, the controller enters the Select-DR-Scan state. 105 of 129 DS26504 T1/E1/J1/64KCC BITS Element Figure 17-2. TAP Controller State Diagram 1 Test Logic Reset 0 0 Run Test/ Idle 1 Select DR-Scan 1 Select IR-Scan 0 1 0 1 Capture DR Capture IR 0 Shift DR 0 Shift IR 0 1 Exit DR Exit IR Pause IR 0 Exit2 DR 1 0 Exit2 IR 1 Update DR 1 1 0 1 0 0 1 1 0 Pause DR 1 0 106 of 129 1 Update IR 1 0 0 DS26504 T1/E1/J1/64KCC BITS Element 17.1 Instruction Register The instruction register contains a shift register as well as a latched parallel output and is 3 bits in length. When the TAP controller enters the Shift-IR state, the instruction shift register is connected between JTDI and JTDO. While in the Shift-IR state, a rising edge on JTCLK with JTMS LOW shifts the data one stage toward the serial output at JTDO. A rising edge on JTCLK in the Exit1-IR state or the Exit2-IR state with JTMS HIGH moves the controller to the Update-IR state. The falling edge of that same JTCLK will latch the data in the instruction shift register to the instruction parallel output. Table 17-1. Instruction Codes for IEEE 1149.1 Architecture INSTRUCTION SAMPLE/PRELOAD BYPASS EXTEST CLAMP HIGHZ IDCODE SELECTED REGISTER Boundary Scan Bypass Boundary Scan Bypass Bypass Device Identification INSTRUCTION CODES 010 111 000 011 100 001 SAMPLE/PRELOAD This is a mandatory instruction for the IEEE 1149.1 specification that supports two functions. The digital I/Os of the device can be sampled at the boundary scan register without interfering with the normal operation of the device by using the Capture-DR state. SAMPLE/PRELOAD also allows the device to shift data into the boundary scan register via JTDI using the Shift-DR state. BYPASS When the BYPASS instruction is latched into the parallel instruction register, JTDI connects to JTDO through the one-bit bypass test register. This allows data to pass from JTDI to JTDO not affecting the device’s normal operation. EXTEST This allows testing of all interconnections to the device. When the EXTEST instruction is latched in the instruction register, the following actions occur. Once enabled via the Update-IR state, the parallel outputs of all digital output pins are driven. The boundary scan register is connected between JTDI and JTDO. The Capture-DR samples all digital inputs into the boundary scan register. CLAMP All digital outputs of the device will output data from the boundary scan parallel output while connecting the bypass register between JTDI and JTDO. The outputs will not change during the CLAMP instruction. HIGHZ All digital outputs of the device will be placed in a high-impedance state. The BYPASS register is connected between JTDI and JTDO. 107 of 129 DS26504 T1/E1/J1/64KCC BITS Element IDCODE When the IDCODE instruction is latched into the parallel instruction register, the identification test register is selected. The device identification code will be loaded into the identification register on the rising edge of JTCLK following entry into the capture-DR state. Shift-DR can be used to shift the identification code out serially via JTDO. During Test-Logic-Reset, the identification code is forced into the instruction register’s parallel output. The ID code will always have a 1 in the LSB position. The next 11 bits identify the manufacturer’s JEDEC number and number of continuation bytes followed by 16 bits for the device and 4 bits for the version Table 17-2. Table 17-3 lists the device ID codes. Table 17-2. ID Code Structure MSB Version Contact Factory 4 bits LSB Device ID JEDEC 1 16 bits 00010100001 1 Table 17-3. Device ID Codes DEVICE DS26502 DS26503 DS26504 16-BIT ID 0035h 0036h 0034h 17.2 Test Registers IEEE 1149.1 requires a minimum of two test registers: the bypass register and the boundary scan register. An optional test register has been included with the DS26504 design. This test register is the identification register and is used with the IDCODE instruction and the Test-Logic-Reset state of the TAP controller. 17.3 Boundary Scan Register This register contains both a shift register path and a latched parallel output for all control cells and digital I/O cells and is n bits in length. See Table 17-4 for the cell bit locations and definitions. 17.4 Bypass Register This is a single 1-bit shift register used with the BYPASS, CLAMP, and HIGHZ instructions that provides a short path between JTDI and JTDO. 17.5 Identification Register The identification register contains a 32-bit shift register and a 32-bit latched parallel output. This register is selected during the IDCODE instruction and when the TAP controller is in the Test-Logic-Reset state. 108 of 129 DS26504 T1/E1/J1/64KCC BITS Element Table 17-4. Boundary Scan Control Bits CELL # NAME TYPE 0 AD1 Output3 1 AD1_7_CTRL Controlr 2 AD0 Output3 3 AD0_CTRL Controlr 4 WR_RW observe_only 5 RD_DS observe_only 6 CS observe_only 7 BIS1 observe_only 8 BIS0 observe_only 9 BTS observe_only 10 THZE observe_only 11 TMODE1 observe_only 12 TMODE2 observe_only 13 PLL_CLK observe_only 14 INT Output3 15 INT_CTRL Controlr 16 TSTRST observe_only 17 RLOS observe_only 18 TCSS1 observe_only 19 RLOF_CCE observe_only 20 RAIS observe_only 21 RSER observe_only 22 OUT_400HZ observe_only 23 RS_8K observe_only 24 RCLK observe_only 25 TS_8K_4 Output3 26 TS_8K_4_CTRL Controlr 27 TSER observe_only 28 TPOSO observe_only CONTROL CELL 1 3 15 26 109 of 129 DS26504 T1/E1/J1/64KCC BITS Element CONTROL CELL CELL # NAME TYPE 29 TNEGO observe_only 30 TCLKO observe_only 31 TCLK observe_only 32 ALE_A7 observe_only 33 A6 observe_only 34 A5 observe_only 35 A4 observe_only 36 A3 observe_only 37 A2 observe_only 38 A1 observe_only 39 A0 observe_only 40 AD7 Output3 1 41 AD6 Output3 1 42 AD5 Output3 1 43 AD4 Output3 1 44 AD3 Output3 1 45 AD2 Output3 1 110 of 129 DS26504 T1/E1/J1/64KCC BITS Element 18. FUNCTIONAL TIMING DIAGRAMS 18.1 Processor Interface 18.1.1 Parallel Port Mode See the AC Timing section. 18.1.2 SPI Serial Port Mode Figure 18-1. SPI Serial Port Access, Read Mode, CPOL = 0, CPHA = 0 SCK CS MOSI 1 0 0 0 0 0 0 MSB A7 A6 LSB MSB A5 A4 A3 A2 A1 A0 B LSB MISO D7 D6 D5 D4 D3 D2 D1 MSB D0 LSB Figure 18-2. SPI Serial Port Access, Read Mode, CPOL = 1, CPHA = 0 SCK CS MOSI 1 0 0 0 0 0 0 MSB A7 A6 LSB MSB A5 A4 A3 A2 A1 A0 B LSB MISO D7 D6 D5 D4 D3 D2 D1 MSB D0 LSB Figure 18-3. SPI Serial Port Access, Read Mode, CPOL = 0, CPHA = 1 SCK CS MOSI 1 MSB 0 0 0 0 0 0 A7 A6 LSB MSB A5 A4 A3 A2 A1 A0 B LSB MISO D7 MSB 111 of 129 D6 D5 D4 D3 D2 D1 D0 LSB DS26504 T1/E1/J1/64KCC BITS Element Figure 18-4. SPI Serial Port Access, Read Mode, CPOL = 1, CPHA = 1 SCK CS MOSI 1 0 0 0 0 0 0 MSB A7 A6 LSB MSB A5 A4 A3 A2 A1 A0 B LSB MISO D7 D6 D5 D4 D3 D2 D1 MSB D0 LSB Figure 18-5. SPI Serial Port Access, Write Mode, CPOL = 0, CPHA = 0 SCK CS MOSI 0 0 0 0 0 0 0 MSB A7 A6 LSB MSB A5 A4 A3 A2 A1 A0 B D7 LSB MSB D6 D5 D4 D3 D2 D1 MISO Figure 18-6. SPI Serial Port Access, Write Mode, CPOL = 1, CPHA = 0 SCK CS MOSI 0 MSB 0 0 0 0 0 0 A7 A6 LSB MSB A5 A4 A3 A2 MISO 112 of 129 A1 A0 B D7 LSB MSB D6 D0 LSB D5 D4 D3 D2 D1 D0 LSB DS26504 T1/E1/J1/64KCC BITS Element Figure 18-7. SPI Serial Port Access, Write Mode, CPOL = 0, CPHA = 1 SCK CS MOSI 0 0 0 0 0 0 0 A7 MSB A6 A5 A4 A3 A2 A1 A0 D7 B D6 D5 D4 D3 D2 D1 LSB MSB LSB MSB D0 LSB MISO Figure 18-8. SPI Serial Port Access, Write Mode, CPOL = 1, CPHA = 1 SCK CS MOSI 0 MSB 0 0 0 0 0 0 A7 A6 A5 A4 A3 A2 A1 A0 B D7 LSB MSB LSB MSB MISO 113 of 129 D6 D5 D4 D3 D2 D1 D0 LSB DS26504 T1/E1/J1/64KCC BITS Element 19. OPERATING PARAMETERS ABSOLUTE MAXIMUM RATINGS Voltage Range on Any Pin Relative to Ground………………………………………………………-1.0V to +6.0V Operating Temperature Range for DS26504L…………………………………………………………0°C to +70°C Operating Temperature Range for DS26504LN……………………………………………-40°C to +85°C (Note 1) Storage Temperature Range………………………………………………………………………...-55°C to +125°C Soldering Temperature………………………………………………….….See IPC/JEDEC J-STD-20 Specification This is a stress rating only and functional operation of the device at these or any other conditions above those indicated in the operation sections of this specification is not implied. Exposure to absolute maximum rating conditions for extended periods of time can affect reliability. Note 1: Specifications to -40°C are guaranteed by design (GBD) and not production tested. Table 19-1. Thermal Characteristics PARAMETER Ambient Temperature MIN TYP MAX 85°C Junction Temperature NOTES 2 125°C 45.3°C/W Theta-JA (θJA) in Still Air 3 Table 19-2. Theta-JA (θJA) vs. Airflow FORCED AIR (meters per second) 0 1 2.5 Note 2: Note 3: THETA-JA (θJA) 45.3°C/W 37.2°C/W 34.4°C/W The package is mounted on a four-layer JEDEC standard test board. Theta-JA (θJA) is the junction-to-ambient thermal resistance, when the package is mounted on a four-layer JEDEC standard test board. Table 19-3. Recommended DC Operating Conditions (TA = 0°C to +70°C for DS26504L; TA = -40°C to +85°C for DS26504LN.) PARAMETER SYMBOL MIN Logic 1 VIH Logic 0 Supply Note 3: Note 4: TYP MAX UNITS NOTES 2.0 5.5 V 4 VIL -0.3 +0.8 V 4 VDD 3.135 3.3 3.465 V 5 MIN TYP MAX UNITS NOTES Guaranteed by design (GBD). Applies to RVDD, TVDD, and DVDD. Table 19-4. Capacitance (TA = +25°C) PARAMETER Input Capacitance Output Capacitance SYMBOL CIN 5 pF COUT 7 pF 114 of 129 DS26504 T1/E1/J1/64KCC BITS Element Table 19-5. DC Characteristics (VDD = 3.3V ±5%, TA = 0°C to +70°C for DS26504L; VDD = 3.3V ±5%, TA = -40°C to +85°C for DS26504LN.) PARAMETER SYMBOL MIN TYP MAX UNITS 150 mA +1.0 μA 6 1.0 μA 7 Supply Current IDD Input Leakage IIL Output Leakage ILO Output Current (2.4V) IOH -1.0 mA Output Current (0.4V) IOL +4.0 mA Note 6: Note 7: -1.0 0.0V < VIN < VDD Applied to INT when three-stated. 115 of 129 NOTES DS26504 T1/E1/J1/64KCC BITS Element 20. AC TIMING PARAMETERS AND DIAGRAMS Capacitive test loads are 40pF for bus signals and 20pF for all others. 20.1 Multiplexed Bus Table 20-1. AC Characteristics, Multiplexed Parallel Port (VDD = 3.3V ±5%, TA = 0°C to +70°C for DS26504L; VDD = 3.3V ±5%, TA = -40°C to +85°C for DS26504LN.) (Note 1) (Figure 20-1, Figure 20-2, and Figure 20-3) PARAMETER SYMBOL MIN Cycle Time Pulse Width, DS Low or RD High tCYC PWEL 200 100 Pulse Width, DS High or RD Low Input Rise/Fall Times R/W Hold Time PWEH tR, tF tRWH 100 10 ns ns ns R/W Setup Time Before DS High tRWS 50 ns CS Setup Time Before DS, WR, or RD Active tCS 20 ns CS Hold Time tCH 0 ns Read Data Hold Time tDHR 10 Write Data Hold Time Muxed Address Valid to AS or ALE Fall Muxed Address Hold Time tDHW 5 ns tASL 15 ns tAHL 10 ns tASD 20 ns PWASH 30 ns Delay Time, AS or ALE to DS, WR, or RD tASED 10 ns Output Data Delay Time from DS or RD tDDR Data Setup Time tDSW Delay Time DS, WR, or RD to AS or ALE Rise Pulse Width AS or ALE High Note 1: TYP MAX ns ns 20 50 80 50 The timing parameters in this table are guaranteed by design (GBD). 116 of 129 UNITS ns ns ns NOTES DS26504 T1/E1/J1/64KCC BITS Element Figure 20-1. Intel Bus Read Timing (BTS = 0 / BIS[1:0] = 00) t CYC ALE WR PWASH t ASD t ASD t ASED RD PWEL PWEH t CH t CS CS t ASL t DHR t DDR AD0-AD7 t AHL Figure 20-2. Intel Bus Write Timing (BTS = 0 / BIS[1:0] = 00) t CYC ALE RD PWASH t ASD t ASED t ASD WR PWEL PWEH t CH t CS CS t ASL t DHW AD0-AD7 t AHL 117 of 129 t DSW DS26504 T1/E1/J1/64KCC BITS Element Figure 20-3. Motorola Bus Timing (BTS = 1 / BIS[1:0] = 00) PWASH AS DS PWEH t ASED t ASD PWEL t CYC t RWS t RWH R/W AD0-AD7 (read) t DDR t ASL t AHL t DHR t CH t CS CS AD0-AD7 (write) t DSW t ASL t AHL A8 & A9 118 of 129 t DHW DS26504 T1/E1/J1/64KCC BITS Element 20.2 Nonmultiplexed Bus Table 20-2. AC Characteristics, Nonmultiplexed Parallel Port (VDD = 3.3V ±5%, TA = 0°C to +70°C for DS26504L; VDD = 3.3V ±5%, TA = -40°C to +85°C for DS26504LN.) (Note 1) (Figure 20-4, Figure 20-5, Figure 20-6, and Figure 20-7) PARAMETER Setup Time for A0 to A7, Valid to CS Active Setup Time for CS Active to Either RD, WR, or DS Active Delay Time from Either RD or DS Active to Data Valid Hold Time from Either RD, WR, or DS Inactive to CS Inactive SYMBOL MIN t1 0 ns t2 0 ns t3 TYP MAX 75 UNITS ns t4 0 Hold Time from CS Inactive to Data Bus Three-State t5 5 Wait Time from Either WR or DS Activate to Latch Data t6 75 ns Data Setup Time to Either WR or DS Inactive t7 10 ns Data Hold Time from Either WR or DS Inactive t8 10 ns Address Hold from Either WR or DS Inactive t9 10 ns Note 1: The timing parameters in this table are guaranteed by design (GBD). 119 of 129 ns 20 ns NOTES DS26504 T1/E1/J1/64KCC BITS Element Figure 20-4. Intel Bus Read Timing (BTS = 0 / BIS[1:0] = 01) A0 to A7 Address Valid D0 to D7 Data Valid t5 5ns min/20ns max WR t1 0ns min 0ns min t2 CS t3 t4 75ns max RD 0ns min Figure 20-5. Intel Bus Write Timing (BTS = 0 / BIS[1:0] = 01) A0 to A7 Address Valid D0 to D7 t7 10ns min RD t1 CS 0ns min WR t8 10ns min 0ns min t2 t6 75ns min 120 of 129 t4 0ns min DS26504 T1/E1/J1/64KCC BITS Element Figure 20-6. Motorola Bus Read Timing (BTS = 1 / BIS[1:0] = 01) A0 to A7 Address Valid D0 to D7 Data Valid 5ns min. / 20ns max. t5 R/W t1 CS 0ns min. 0ns min. t2 t3 t4 0ns min. 75ns max. DS Figure 20-7. Motorola Bus Write Timing (BTS = 1 / BIS[1:0] = 01) A0 to A7 Address Valid D0 to D7 10ns min. R/W t1 t7 t8 10ns min. 0ns min. CS 0ns min. DS t2 t6 75ns min. 121 of 129 t4 0ns min. DS26504 T1/E1/J1/64KCC BITS Element 20.3 Serial Bus Table 20-3. AC Characteristics, Serial Bus (VDD = 3.3V ±5%, TA = 0°C to +70°C for DS26504L; VDD = 3.3V ±5%, TA = -40°C to +85°C for DS26504LN.) (Note 1) (Figure 20-8 and Figure 20-9) DIAGRAM NUMBER (Note 2) 1 2 3 4 5 6 7 8 9 10 11 CHARACTERISTIC (Note 3) Operating Frequency Slave Cycle Time: Slave Enable Lead Time Enable Lag Time Clock (CLK) High Time Slave Clock (CLK) Low Time Slave Data Setup Time (inputs) Slave Data Hold Time (inputs) Slave Access Time, Slave (Note 4) SYMBOL MIN MAX fBUS(S) UNITS 10 MHz tCYC(S) tLEAD(S) tLAG(S) 100 15 15 — — — ns ns ns tCLKH(S) 50 — ns tCLKL(S) 50 — ns tSU(S) 5 — ns tH(S) 15 — ns CPHA = 0 tA(CP0) 0 40 CPHA = 1 tA(CP1) 0 20 tDIS(S) — 25 ns tV(S) — 40 ns tHD(S) 5 — ns Disable Time, Slave (Note 5) Data Valid Time, After Enable Edge Slave (Note 6) Data Hold Time, Outputs, After Enable Edge Slave Note 1: The timing parameters in this table are guaranteed by design (GBD). Note 2: Numbers refer to dimensions in Figure 20-8 and Figure 20-9. Note 3: All timing is shown with respect to 20% VDD and 70% VDD, unless otherwise noted. 100pF load on all SPI pins. Note 4: Time to data active from high-impedance state. Note 5: Hold time to high-impedance state. Note 6: With 100pF on all SPI pins. 122 of 129 ns DS26504 T1/E1/J1/64KCC BITS Element Figure 20-8. SPI Interface Timing Diagram, CPHA = 0, BIS[1:0] = 10 CS INPUT 1 3 5 CLK INPUT CPOL = 0 4 2 CLK INPUT CPOL = 1 5 4 8 9 MISO INPUT SLAVE MSB 6 MOSI OUTPUT BITS 6-1 BITS 6-1 MSB NOTE 11 10 7 SLAVE LSB 11 LSB NOTE: NOT DEFINED, BUT USUALLY MSB OF CHARACTER JUST RECEIVED. Figure 20-9. SPI Interface Timing Diagram, CPHA = 1, BIS[1:0] = 10 CS INPUT 1 5 CLK INPUT CPOL = 0 4 2 3 CLK INPUT CPOL = 1 5 4 8 9 10 MISO OUTPUT NOTE 6 MOSI INPUT BITS 6-1 SLAVE MSB SLAVE LSB 11 7 10 BITS 6-1 MSB NOTE: NOT DEFINED, BUT USUALLY LSB OF CHARACTER PREVIOUSLY TRANSMITTED 123 of 129 LSB DS26504 T1/E1/J1/64KCC BITS Element 20.4 Receive Side AC Characteristics Table 20-4. Receive Side AC Characteristics (VDD = 3.3V ±5%, TA = 0°C to +70°C for DS26504L; VDD = 3.3V ±5%, TA = -40°C to +85°C for DS26504LN.) (Note 1) (Figure 20-10) PARAMETER RCLK Period SYMBOL RCLK to RSER Delay RCLK to RS_8K, 400Hz Delay tD2 RCLK Pulse Width UNITS NOTES TYP MAX 200 200 ns ns μs ns ns ns 150 150 ns ns 2 3 4 5 6 6 4 4 7 7 4 4 488 648 15.6 158.4 tCP tCH tCL tCH tCL tCH tCL tCH tCL tD1 RCLK Pulse Width MIN Note 1: The timing parameters in this table are guaranteed by design (GBD). Note 2: E1 mode. Note 3: T1 or J1 mode. Note 4: 64KCC mode. Note 5: 6312kHz mode. Note 6: Jitter attenuator enabled in the receive path. Note 7: Jitter attenuator disabled or enabled in the transmit path. 124 of 129 20 ns 50 ns 2, 3, 4 DS26504 T1/E1/J1/64KCC BITS Element Figure 20-10. Receive Timing—T1, E1, 64KCC Mode RCLK t D1 RSER t D2 E1 = MSB of Channel 1 T1 = F-Bit RS_8K1 t D2 RS_8K2 t D2 400HZ3 NOTES: 1) RS_8K OUTPUT IN T1 OR E1 MODE. 2) RS_8K OUTPUT IN 64KCC MODE. 3) 400Hz OUTPUT ACTIVE ONLY IN 64KCC MODE, HIGH IMPEDANCE IN ALL OTHER MODES. 125 of 129 DS26504 T1/E1/J1/64KCC BITS Element 20.5 Transmit Side AC Characteristics Table 20-5. Transmit Side AC Characteristics (VDD = 3.3V ±5%, TA = -40°C to +85°C.) (Note 1) (Figure 20-11) PARAMETER SYMBOL TCLK Period tCP TCLK Pulse Width tCH tCL TCLK Rise and Fall Times tR, tF TX CLOCK Setup to TSER, TS_8K_4 tSU Delay TX CLOCK to TS_8K_4 tD2 Delay TCLK to PLL_OUT, TX CLOCK Delay TCLKO to TPOSO and TNEGO MIN TYP MAX UNITS NOTES ns ns μs ns ns ns 2 3 4 5 488 648 15.6 158.4 75 75 25 20 ns ns 6, 7 50 ns 7, 8 tD3 20 ns 7, 9 tDD 50 ns Note 1: The timing parameters in this table are guaranteed by design (GBD). Note 2: E1 mode. Note 3: T1 or J1 mode. Note 4: 64KCC mode. Note 5: 6312kHz mode. Note 6: TS_8K_4 in input mode. Note 7: TX CLOCK is an internal signal. Note 8: TS_8K_4 in output mode. Note 9: TX CLOCK is an internal signal that samples TSER and TS_8K_4 when TS_8K_4 is in input mode. 126 of 129 DS26504 T1/E1/J1/64KCC BITS Element Figure 20-11. Transmit Timing—T1, E1, 64KCC Mode t CP t CL tF tR t CH TCLK RCLK, JA CLOCK4 PLL_OUT t D3 TX CLOCK3 t SU TSER t HD t D2 TS_8K_41 t SU TS_8K_42 (REFER TO THE TRANSMIT PLL BLOCK DIAGRAM, 3-3.) NOTE 1: TS_8K_4 IN OUTPUT MODE. NOTE 2: TS_8K_4 IN INPUT MODE. NOTE 3: TX CLOCK IS THE INTERNAL CLOCK THAT DRIVES THE TRANSMIT SECTION. THE SOURCE OF THIS SIGNAL DEPENDS ON THE CONFIGURATION OF THE TRANSMIT PLL. IF TX CLOCK IS GENERATED BY THE TRANSMIT PLL (CONVERSION FROM ANOTHER CLOCK RATE) THEN THE USER SHOULD OUTPUT THAT SIGNAL ON THE PLL_OUT PIN AND USE THAT SIGNAL TO REFERENCE TSER AND TS_8K_4 IF TS_8K_4 IS IN THE INPUT MODE. NOTE 4: RCLK (THE RECOVERED LINE CLOCK) AND JA CLOCK (AN INTERNAL CLOCK DERIVED FROM MCLK) MAY BE SELECTED AS THE SOURCE FOR THE TRANSMIT PLL OR USED UNCONVERTED FOR TX CLOCK. 127 of 129 DS26504 T1/E1/J1/64KCC BITS Element 21. REVISION HISTORY REVISION DATE DESCRIPTION 070105 New product release. 081105 Corrected the polarity of the TAIS pin when operating in Hardware mode. 101805 020906 053107 100507 121707 042208 072308 PAGES CHANGED — 19, 29 N Changed Section 13.4 to read “2.048 x 2 (where N = 1 to 3)” instead of “2.048 x N (where N = 1 to 4).” Section 13.3.1, Section 13.3.2, SR1 Bits 1 and 2: Clarified the open circuit and short circuit wording. Figure 13-1: Corrected the capacitor value from 1μF to 10μF. Replaced Figure 13-4 and 13-5 (added Table 13-1 and Table 13-2) to show two different types of recommended protection circuit interfaces. Added package drawing link to Package Information section, along with updated package drawing. Removed reference to E1RCR and E1TCR bit 3 (this bit functionality has been moved to the MCREG). Replaced Figure 13-4 and Figure 13-5 to show 10μF cap on TTIP. In the Absolute Maximum Ratings (Section 19), added Note 1: Specifications at -40°C are guaranteed by design GBD and not production tested. to Operating Temp Range for DS26504LN. Renumbered notes for Table 19-1 to Table 19-5. Clarified RITD and TITD descriptions. For E1TS description, changed 0 = 120Ω and 1 = 75Ω to 0 = 75Ω and 1 = 120Ω. Corrected Note 2 in the LIC1[7:5] register description to include TT2 along with TT0 and TT1. In Section 13, corrected the wording to clearly indicate that different transformers are required for T1, J1, E1, and 6312kHz modes and for 64KCC mode. In Table 7-2, changed address 21 and 22 from “—” to “SR5” and “IMR5”; added bit 4 (SR5) to IIR. 128 of 129 48 92, 93 113, 114 16, 17 19 84 79 32, 39 DS26504 T1/E1/J1/64KCC BITS Element 22. PACKAGE INFORMATION (The package drawing(s) in this data sheet may not reflect the most current specifications. The package number provided for each package is a link to the latest package outline information.) 22.1 64-Pin LQFP (56-G4019-001) 129 of 129 Maxim/Dallas Semiconductor cannot assume responsibility for use of any circuitry other than circuitry entirely embodied in a Maxim/Dallas Semiconductor product. No circuit patent licenses are implied. Maxim/Dallas Semiconductor reserves the right to change the circuitry and specifications without notice at any time. Maxim Integrated Products, 120 San Gabriel Drive, Sunnyvale, CA 94086 408-737-7600 © 2008 Maxim Integrated Products The Maxim logo is a registered trademark of Maxim Integrated Products, Inc. The Dallas logo is a registered trademark of Dallas Semiconductor.
DS26504LN+T&R 价格&库存

很抱歉,暂时无法提供与“DS26504LN+T&R”相匹配的价格&库存,您可以联系我们找货

免费人工找货