EVALUATION KIT AVAILABLE
MAX44007
LE
AVAILAB
Low-Power Digital Ambient Light Sensor
with Enhanced Sensitivity
General Description
Features
The MAX44007 ambient light sensor features an I2C
S Wide 0.025 Lux to 104,448 Lux Range
digital output that is ideal for a number of portable applications such as smartphones, notebooks, and industrial
sensors. At less than 1µA operating current, it is the
lowest power ambient light sensor in the industry and
features an ultra-wide 22-bit dynamic range from 0.025
lux to 104,448 lux.
S Small, 2mm x 2mm x 0.6mm UTDFN-Opto
Low-light operation allows easy operation in dark glass
applications.
The on-chip photodiode’s spectral response is optimized
to mimic the human eye’s perception of ambient light
and incorporates IR and UV blocking capability. The
adaptive gain block automatically selects the correct lux
range to optimize the counts/lux.
The IC includes two I2C slave address options: 1011
010x and 1011 011x.
S VCC = 1.7V to 3.6V
S ICC = 0.65µA Operating Current
S -40NC to +85NC Temperature Range
S Improved Sensitivity Behind Dark Glass
Ordering Information
PART
PIN-PACKAGE
TEMP RANGE
MAX44007EDT+
6 UTDFN-Opto-EP*
-40NC to +85NC
+Denotes a lead(Pb)-free/RoHS-compliant package.
*EP = Exposed pad.
The IC is designed to operate from a 1.7V to 3.6V supply voltage range and consumes only 0.65µA in full
operation. It is available in a small, 2mm x 2mm x 0.6mm
UTDFN-Opto package.
Block Diagram
Applications
VCC
Tablet PCs/Notebook Computers
TVs/Projectors/Displays
Digital Lighting Management
Portable Devices
Functional
VISIBLE +IR
PHOTODIODE
Diagrams
Cellular Phones/Smartphones
Security Systems
MAX44007
IR
PHOTODIODE
SDA
16-BIT
ADC
6-BIT RANGE
CDR, TIM
CONTROL
SCL
I2C
AO
DIGITAL
SIGNAL
PROCESSING
INT
16-BIT
ADC
N
GND
Pin Configurations appear at end of data sheet.
Functional Diagrams continued at end of data sheet.
UCSP is a trademark of Maxim Integrated Products, Inc.
For pricing, delivery, and ordering information, please contact Maxim Direct
at 1-888-629-4642, or visit Maxim’s website at www.maximintegrated.com.
19-5492; Rev 1; 6/11
MAX44007
Low-Power Digital Ambient Light Sensor
with Enhanced Sensitivity
ABSOLUTE MAXIMUM RATINGS
INT to GND................................................ -0.3V to (VCC + 0.3V)
All Other Pins to GND..............................................-0.3V to +4V
INT Short-Circuit Current Duration......................................... 10s
All Other Pins Short-Circuit Current Duration.............Continuous
Continuous Input Current into Any Terminal.................... Q20mA
Continuous Power Dissipation
6 UTDFN-Opto (derate 11.9mW/NC above +70NC)......953mW
Operating Temperature Range........................... -40NC to +85NC
Soldering Temperature (reflow).......................................+260NC
Stresses beyond those listed under “Absolute Maximum Ratings” may cause permanent damage to the device. These are stress ratings only, and functional
operation of the device at these or any other conditions beyond those indicated in the operational sections of the specifications is not implied. Exposure to absolute
maximum rating conditions for extended periods may affect device reliability.
ELECTRICAL CHARACTERISTICS
(VCC = 1.8V, TMIN to TMAX = -40NC to +85NC, unless otherwise noted.) (Note 1)
PARAMETER
SYMBOL
CONDITIONS
MIN
TYP
MAX
UNITS
OPTICAL CHARACTERISTICS
Maximum Lux Sensitivity
Fluorescent light
Saturation Ambient Lux Level
Sunlight
Total Error
TE
Light Source Matching
0.025
Lux/LSB
104,448
Lux
Green LED 538nm response,
TA = +25NC (Note 2)
15
Fluorescent/incandescent light under dark
glass
10
%
%
Infrared Transmittance at 850nm
IRR
TA = +25NC (Note 3)
2
3
%
Ultraviolet Transmittance at
363nm
UVR
TA = +25NC (Note 3)
1.2
3
%
Dark Level Count
0LUX
0 lux, TA = +25NC, 800ms range
0
0.025
Lux
Maximum Signal Integration
Time
Minimum Signal Integration Time
ADC Conversion Time
Has 50/60Hz rejection
800
Automatic mode, has 50/60Hz rejection
100
Manual mode only
6.25
100
103
ACT
100ms range, TA = +25NC
100ms range
99.6
97
VCC
Guaranteed by TE test
1.7
ms
ms
100.4
107
ms
3.6
V
POWER SUPPLY
Power-Supply Voltage
Power-Supply Current
ICC
0.65
TA = +25NC, 100 lux, I2C inputs inactive
1.2
1.6
TA = -40NC to +85NC
FA
DIGITAL I/O CHARACTERISTICS
ISINK = 6mA
0.06
0.4
V
TA = +25NC
0.01
20
nA
IIH, IIL
TA = +25NC
0.01
20
nA
I2C Input Low Voltage
VIL_I2C
SDA, SCL
0.3 x
VCC
V
I2C Input High Voltage
VIH_I2C
SDA, SCL
Address Input Low Voltage
VIL_A0
A0
Address Input High Voltage
VIH_A0
A0
VOL
Output Low Voltage SDA, INT
INT Leakage Current
SCL, SDA, A0 Input Current
Input Capacitance
2
0.7 x
VCC
V
0.3
VCC 0.3V
V
V
3
pF
Maxim Integrated
MAX44007
Low-Power Digital Ambient Light Sensor
with Enhanced Sensitivity
ELECTRICAL CHARACTERISTICS (continued)
(VCC = 1.8V, TMIN to TMAX = -40NC to +85NC, unless otherwise noted.) (Note 1)
PARAMETER
I2C
SYMBOL
CONDITIONS
MIN
TYP
MAX
UNITS
400
kHz
TIMING
Serial-Clock Frequency
fSCL
Bus Free Time Between a STOP
and a START Condition
tBUF
1.3
Fs
tHD,STA
0.6
Fs
Low Period of the SCL Clock
tLOW
1.3
Fs
High Period of the SCL Clock
tHIGH
0.6
Fs
Setup Time for a Repeated
START Condition
tSU,STA
0.6
Fs
Data Hold Time
tHD,DAT
(Note 4)
Data Setup Time
tSU,DAT
Hold Time (Repeated) START
Condition
Fall Time of SDA Transmitting
Setup Time for STOP Condition
Pulse Width of Spike
Suppressed
tF
ISINK P 6mA, tR and tF are measured
between 0.3 x VDD and 0.7 x VDD
tSU,STO
tSP
0
0.9
100
ns
100
ns
0.6
Input filters on the SDA and SCL inputs
suppress noise spikes
0
Fs
Fs
50
ns
Note 1: All devices are 100% production tested at TA = +25NC. Temperature limits are guaranteed by design.
Note 2: Guaranteed by design. Green 538nm LED chosen for production so that the IC responds to100 lux fluorescent light with
100 lux.
Note 3: With respect to green LED 538nm response.
Note 4: A master device must provide a hold time of at least 300ns for the SDA signal (referred to VIL of the SCL signal) to bridge
the undefined region of SCL’s falling edge.
Maxim Integrated
3
MAX44007
Low-Power Digital Ambient Light Sensor
with Enhanced Sensitivity
Typical Operating Characteristics
(VCC = 1.8V, default power-up setting; unless otherwise noted.)
RADIATION PATTERN
SPECTRUM RESPONSE
80
60
40
CIE
20
MAX44007 toc02
MAX44007 RESPONSE
90
80
70
60
50
40
30
AUTO MODE,
INCANDESCENT LAMP
20
10
0
0
400
500
600
700
800
900
-90
1000
-60
-30
SPECTRUM OF LIGHT SOURCES
FOR MEASUREMENT
MAX44007 toc03
120
SUNLIGHT
80
60
40
FLUORESCENT
1.0
400
500 600 700 800
WAVELENGTH (nm)
0.8
0.6
1.04
1.02
1.00
0.98
0.96
0.94
50 AND 300 LUX
AUTO MODE,
FLUORESCENT LAMP
0.92
0.90
1.5
1.8
2.1
2.4
2.7
3.0
SUPPLY VOLTAGE (V)
2.1
2.4
2.7
3.0
3.3
3.6
SUPPLY CURRENT vs. TEMPERATURE
1.2
VCC = 3.3V
1.0
SUPPLY CURRENT (µA)
1.06
1.8
SUPPLY VOLTAGE (V)
MAX44007 toc05
1.08
AUTO MODE,
FLUORESCENT LAMP
1.5
OUTPUT CODE ERROR vs. SUPPLY VOLTAGE
OUTPUT CODE ERROR (RATIO FROM 1.8V)
100 LUX, CONT = 0
0.4
900 1000
1.10
4
5000 LUX, CONT = 0
0
0
300
90
0 LUX AND 100 LUX, CONT = 1
0.2
20
60
1.2
SUPPLY CURRENT (µA)
NORMALIZED RESPONSE
INCANDESCENT
100
30
SUPPLY CURRENT vs. SUPPLY VOLTAGE
1.4
160
140
0
LUMINOSITY ANGLE (°)
WAVELENGTH (nm)
MAX44007 toc04
300
MAX44007 toc06
NORMALIZED RESPONSE
100
100
RELATIVE SENSITIVITY (% FROM 0°)
MAX44007 toc01
120
0.8
0.6
VCC = 2.5V
VCC = 1.8V
0.4
100 LUX
AUTO MODE,
FLUORESCENT LAMP
0.2
0
3.3
3.6
-40
-15
10
35
60
85
TEMPERATURE (°C)
Maxim Integrated
MAX44007
Low-Power Digital Ambient Light Sensor
with Enhanced Sensitivity
Typical Operating Characteristics (continued)
(VCC = 1.8V, default power-up setting; unless otherwise noted.)
2.5
2.0
1.5
1.0
INCANDESCENT
LAMP
200
150
FLUORESCENT
LAMP
100
50
0.5
SUNLIGHT
0
100
1k
10k
0
100k
0
LUX READING (LUX)
100
200
300
400
REFERENCE METER READING (lux)
500
120
110
100
90
80
70
60
50
40
30
20
10
0
MAX44007 toc09
300
VOL (mV)
SUPPLY CURRENT (µA)
3.0
350
MAX44007 READING (counts)
MAX44007 toc07
3.5
SDA INT OUTPUT LOW VOLTAGE
vs. SINK CURRENT
MAX44007 READING vs. LUX LEVEL
SUPPLY CURRENT vs. LUX READING
SDA
INT
0
1
2
3
4 5 6
ISINK (mA)
7
8
9
10
Pin Configuration
TOP VIEW
SDA
SCL
INT
6
5
4
MAX44007
+
EP
1
2
3
VCC
GND
A0
UTDFN-Opto
(2mm x 2mm)
Pin Description
PIN
NAME
1
VCC
Power Supply
2
GND
Ground
3
A0
4
Interrupt Output. Use an external pullup resistor.
5
INT
SCL
6
SDA
I2C Data Bus
—
EP
Maxim Integrated
PIN DESCRIPTION
Address Select. Pull high to select address 1011 011x or low to select address 1011 010x.
I2C Clock Bus
Exposed Pad. Connect EP to ground.
5
MAX44007
Low-Power Digital Ambient Light Sensor
with Enhanced Sensitivity
Detailed Description
IR component of incoming light. By allowing the user to
adjust the internal gain settings to compensate for the
dark glass’ profile, the IC excels in challenging low-light
level applications. contact the factory for more details.
The MAX44007 is an ambient light sensor with integrated
photodiode and ADC with an I2C digital interface. To
measure ambient light, the die is placed inside an optically transparent (UTDFN-Opto) package. A photodiode inside the IC converts the light to a current that is
then processed by low-power circuitry into a digital bit
stream. This is digitally processed and stored in an output register that is read by an I2C interface. An on-chip
programmable interrupt function eliminates the need for
continually polling the device for data and results in significant power saving.
The default integration time of the ADC is 100ms, giving
it inherent rejection of 50Hz and 60Hz ripple common in
certain line-powered light sources.
Human Eye CIE Curve and
Different Light Sources
The IC is designed to detect brightness in the same way
as human eyes do. To achieve this, the sensor needs to
have a spectral sensitivity that is similar to that of human
eyes. Figure 1 shows the spectral sensitivity of the IC
and the human eye (CIE curve).
As can be seen, the human eye has its peak sensitivity
at 555nm (green), while that of blue (~470nm) and red
(~630nm) is much lower. The human eye also is blind to
infrared (> 700nm) and ultraviolet (< 400nm) radiation.
Light sources can have similar visible brightness (lux), but
different IR radiation content (because the human eye is
blind to it). The differences in the light spectra affect brightness measurement because some of this infrared radiation
is picked up by silicon photodiodes. For example, light
sources with high IR content, such as an incandescent
bulb or sunlight, would suggest a much brighter environment than our eyes would perceive them to be. Other light
sources, such as fluorescent and LED-based systems,
have very little infrared content. The IC exhibits good IR
rejection and internal IR compensation scheme to minimize
these effects and give an accurate lux response.
A package-level optical filter prevents ultraviolet
and infrared from reaching the photodiode. Its optical response is also designed to match the spectral
response of the human eye. A second photodiode array,
sensitive primarily to the infrared spectrum, is then used
to match flourescent and incandescent light response
from the part.
Two key features of the IC analog design are its ultra-low
current consumption (typically 0.65µA) and an extremely
wide dynamic light range that extends from 0.025 lux to
104,448 lux—more than a 4,000,000 to 1 range. The onchip autoranging scheme requires no user intervention
for the gain-range setting.
As darkened glass or translucent materials can be transparent to IR wavelengths while attenuating visible light
by 20–50 times or more, the IC dual-photodiode architecture can be utilized to compensate for the increased
120
NORMALIZED RESPONSE
100
MAX44007 RESPONSE
80
60
40
CIE
20
0
300
400
500
600
700
800
900
1000
WAVELENGTH (nm)
Figure 1. Spectral Sensitivity of the MAX44007 and Human Eye
6
Maxim Integrated
MAX44007
Low-Power Digital Ambient Light Sensor
with Enhanced Sensitivity
Register and Bit Descriptions
Table 1. Register Map
BIT
REGISTER
REGISTER
ADDRESS
POWER-ON
RESET
STATE
R/W
7
6
5
4
3
2
1
0
Interrupt Status
—
—
—
—
—
—
—
INTS
0x00
0x00
R
Interrupt Enable
—
—
—
—
—
—
—
INTE
0x01
0x00
R/W
CONT
MANUAL
—
—
CDR
0x02
0x03
R/W
Lux High Byte
E3
E2
E1
E0
M7
M6
M5
M4
0x03
0x00
R
Lux Low Byte
—
—
—
—
M3
M2
M1
M0
0x04
0x00
R
Upper Threshold
High Byte
UE3
UE2
UE1
UE0
UM7
UM6
UM5
UM4
0x05
0xFF
R/W
Lower Threshold
High Byte
LE3
LE2
LE1
LE0
LM7
LM6
LM5
LM4
0x06
0x00
R/W
Threshold Timer
T7
T6
T5
T4
T3
T2
T1
T0
0x07
0xFF
R/W
Adv1 Register
X
X
X
X
X
X
X
X
0x09
0xXX
R/SW
Adv2 Register
X
X
X
X
X
X
X
X
0xA
0xXX
R/SW
Visible Gain
Register
X
X
X
X
X
X
X
X
0xB
0xXX
R/SW
IR Gain Register
X
X
X
X
X
X
X
X
0xC
0xXX
R/SW
Trim Enable
Register
1
0
0
0
0
0
0
ADV
OxD
0x80
R/W
STATUS
CONFIGURATION
Configuration
TIM[2:0]
LUX READING
THRESHOLD SET
THRESHOLD SET
Maxim Integrated
7
MAX44007
Low-Power Digital Ambient Light Sensor
with Enhanced Sensitivity
Interrupt Status 0x00
BIT 7
BIT 6
BIT 5
BIT 4
BIT 3
BIT 2
BIT 1
BIT 0
REGISTER
ADDRESS
—
—
—
—
—
—
—
INTS
0x00
If the INTE bit is set to 1, then the INTS status bit is asserted if the light intensity exceeds either upper or lower threshold
limits (as specified by registers 0x05 and 0x06, respectively) for a period longer than that defined by the Threshold
Timer register (0x07). This bit resets to 0 after the host reads this register. See Table 2.
This bit is also reflected on the INT pin. When the INTS bit is set, the INT pin is asserted low, and when the INTS bit is
set to 0, the INT pin is pulled high by an external resistor.
Once this bit is set, it can be cleared either by reading the Interrupt Status register 0x00 or by writing a 0 to the Interrupt
Enable register 0x01.
Table 2. Interrupt Status Register
BIT 0
OPERATION
0
No interrupt trigger event has occurred.
1
Ambient light intensity is outside the threshold window range for a longer than specified time.
Interrupt Enable 0x01
BIT 7
BIT 6
BIT 5
BIT 4
BIT 3
BIT 2
BIT 1
BIT 0
REGISTER
ADDRESS
—
—
—
—
—
—
—
INTE
0x01
Interrupt events set the INTS bit (register 0x00, bit 0) and the INT pin only if the INTE bit is set to 1. If the INTE bit is set
(interrupt is enabled) and the interrupt condition is triggered, then the INT pin is pulled low (asserted) and the INTS bit
in the Interrupt Status register is set to 1. See Table 3.
Table 3. Interrupt Enable Register
BIT 0
OPERATION
0
The INT pin and the INTS bit are not asserted even if an interrupt event has occurred.
1
Detection of an interrupt event triggers a hardware interrupt (INT pin is pulled low) and sets the INTS bit
(register 0x00, bit 0).
Configuration 0x02
8
BIT 7
BIT 6
BIT 5
BIT 4
BIT 3
CONT
MANUAL
—
—
CDR
BIT 2
BIT 1
TIM[2:0]
BIT 0
REGISTER
ADDRESS
0x02
Maxim Integrated
MAX44007
Low-Power Digital Ambient Light Sensor
with Enhanced Sensitivity
Continuous Mode
Table 4. Continuous Mode Register
BIT 7
OPERATION
0
Default mode. The IC measures lux intensity only once every 800ms regardless of integration time. This mode
allows the part to operate at its lowest possible supply current.
1
Continuous mode. The IC continuously measures lux intensity. That is, as soon as one reading is finished, a
new one begins. If integration time is 6.25ms, readings are taken every 6.25ms. If integration time is 800ms,
readings are taken every 800ms. In this mode, the part consumes slightly higher power than in the default
mode.
Note: Continuous mode is independent of the manual configuration mode setting.
Manual Configuration Mode
In automatic mode (MANUAL = 0), reading the contents of TIM[2:0] and CDR bits reflects the automatically generated
values from an internal timing register and are read-only. In manual mode (MANUAL = 1), the contents of TIM[2:0] and
CDR bits can be modified by the users through the I2C bus.
Table 5. Manual Configuration Register
BIT 6
OPERATION
0
Default mode of configuration is used for the IC. In this mode, CDR, TIM[2:0] bits are automatically
determined by the internal autoranging circuitry of the IC.
1
Manual mode of configuration is used for the IC. In this mode, CDR, and TIM[2:0] bits can be programmed by
the user.
Current Division Ratio (CDR)
The CDR bit controls the current division ratio. The photodiode current is divided as shown in Table 6.
Table 6. Current Division Ratio Register
BIT 3
OPERATION
0
Current not divided. All of the photodiode current goes to the ADC.
1
Current divided by 8. Only 1/8 of the photodiode current goes to the ADC. This mode is used in
high-brightness situations.
Maxim Integrated
9
MAX44007
Low-Power Digital Ambient Light Sensor
with Enhanced Sensitivity
Integration Timer Bits (TIM[2:0])
The TIM[2:0] bits can be used to program the signal integration time.
In automatic mode (MANUAL = 0), integration time is automatically selected by the on-chip algorithm to be either
100ms/200ms/400ms/800ms. In manual mode, integration time can be varied by the user all the way from 6.25ms to
800ms. See Table 7.
Table 7. Integration Time
TIM[2:0]
INTREGRATION
TIME (ms)
COMMENTS
000
800
This is a preferred mode for boosting low-light sensitivity.
001
400
—
010
200
—
011
100
This is a preferred mode for high-brightness applications.
100
50
Manual mode only.
101
25
Manual mode only.
110
12.5
Manual mode only.
111
6.25
Manual mode only.
Lux High-Byte Register 0x03
BIT 7
BIT 6
BIT 5
BIT 4
BIT 3
BIT 2
BIT 1
BIT 0
REGISTER
ADDRESS
E3
E2
E1
E0
M7
M6
M5
M4
0x03
Bits in Lux High-Byte register 0x03 give the 4 bits of exponent E3:E0 and 4 most significant bits of the mantissa byte
M7:M4, and represent the lux reading of ambient light. The remaining 4 bits of the mantissa byte M3:M0 are in the Lux
Low-Byte register 0x04 and enhance resolution of the lux reading from the IC.
Exponent (E[3:0]): Exponent bits of the lux reading (0000 to 1110). Note: A reading of 1111 represents an overrange
condition.
Mantissa (M[7:4]): Four most significant bits of mantissa byte of the lux reading (0000 to 1111).
Lux = 2(exponent) x mantissa x 0.4
Exponent = 8xE3 + 4xE2 + 2xE1 + E0
Mantissa = 8xM7 + 4xM6 + 2xM5 + M4
A code of 0000 0001 calculates to be 0.4 lux.
A code of 1110 1111 calculates to be 98,304 lux.
A code of 1110 1110 calculates to be 91,751 lux.
Update of the contents of this register is internally disabled during I2C read operations to ensure proper data transfer
between internal ADC and I2C registers. Update of I2C registers is resumed when the master sends a STOP command.
If user wants to read both the Lux High-Byte register 0x03 and Lux Low-Byte register 0x04, then the master should
not send a STOP command between the reads of the two registers. Instead a REPEATED START command should
be used. This ensures accurate data is obtained from the I2C registers (by disabling internal updates during the read
process).
10
Maxim Integrated
MAX44007
Low-Power Digital Ambient Light Sensor
with Enhanced Sensitivity
Lux Low-Byte Register 0x04
BIT 7
BIT 6
BIT 5
BIT 4
BIT 3
BIT 2
BIT 1
BIT 0
REGISTER
ADDRESS
—
—
—
—
M3
M2
M1
M0
0x04
Bits in Lux Low-Byte register 0x04 give the 4 least significant bits of the mantissa byte representing the lux reading
of ambient light. Combined with the Lux High-Byte register 0x03, it extends the resolution and dynamic range of lux
measurements of the IC.
E3–E0: Exponent bits of lux reading
M7–M0: Mantissa byte of lux reading
Lux = 2(exponent) x mantissa x 0.025
Exponent = 8xE3 + 4xE2 + 2xE1 + E0
Mantissa = 128xM7 + 64xM6 + 32xM5 + 16xM4 + 8xM3 + 4xM2 + 2xM1 + M0
Combining contents of register 0x03 and 0x04:
A code of 0000 0000 0001 calculates to be 0.025 lux.
A code of 0000 0001 0000 calculates to be 0.4 lux.
A code of 0001 0001 0001 calculates to be 0.425 lux.
A code of 1110 1111 1111 calculates to be 104,448 lux.
A code of 1110 1111 1110 calculates to be 104,038 lux.
The Lux High-Byte 0x03 and Lux Low-Byte 0x04 register updates are internally disabled at the start of a valid address
transmission from the master. Updating reinitiates at the next valid STOP condition. This prevents erroneous readings,
in the event an update occurs between readings of registers 0x03 and 0x04.
Update of the contents of this register is internally disabled during I2C read operations to ensure proper data transfer
between internal ADC and I2C registers. Update of I2C registers is resumed when the master sends a STOP command.
If the user wants to read both the Lux High-Byte register 0x03 and Lux Low-Byte register 0x04, then the master should
not send a STOP command between the reads of the two registers. Instead a REPEATED START command should
be used. This ensures accurate data is obtained from the I2C registers (by disabling internal updates during the read
process).
Upper Threshold High-Byte Register 0x05
BIT 7
BIT 6
BIT 5
BIT 4
BIT 3
BIT 2
BIT 1
BIT 0
REGISTER
ADDRESS
UE3
UE2
UE1
UE0
UM7
UM6
UM5
UM4
0x05
The Upper Threshold High-Byte register exponent with the four most significant bits of the mantissa sets the upper trip
level for interrupt functionality. This upper limit is relevant only if the INTE bit in the interrupt enable register is set. If the
lux level is greater than this light level for a time greater than that specified in the Threshold Timer register, the INTS
bit in the Interrupt Status register is set and the INT pin is pulled low.
Mantissa (UM[7:4]): Four most significant bits of mantissa upper threshold
Exponent (UE[3:0]): Exponent bits upper threshold
Upper lux threshold = 2(exponent) x mantissa x 0.025
Exponent = 8xUE3 + 4xUE2 + 2xUE1 + UE0
Mantissa = 128xUM7+ 64xUM6+ 32xUM5 + 16xUM4 +15
Maxim Integrated
11
MAX44007
Low-Power Digital Ambient Light Sensor
with Enhanced Sensitivity
Lower Threshold High-Byte Register 0x06
BIT 7
BIT 6
BIT 5
BIT 4
BIT 3
BIT 2
BIT 1
BIT 0
REGISTER
ADDRESS
LE3
LE2
LE1
LE0
LM7
LM6
LM5
LM4
0x06
The Lower Threshold High-Byte register exponent with the four most significant bits of the mantissa sets the lower trip
level for interrupt functionality. This lower limit is relevant only if the INTE bit in the Interrupt Enable register is set. If the
lux level is below this light level for a time greater than that specified in the Threshold Timer register, the INTS bit in the
Interrupt Status register is set and the INT pin is pulled low.
Mantissa (LM[7:4]): Four most significant bits of mantissa lower threshold
Exponent (LE[3:0]): Exponent bits lower threshold
Lower lux threshold = 2(exponent) x mantissa x 0.025
Exponent = 8xLE3 + 4xLE2 + 2xLE1 + LE0
Mantissa = 128xLM7 + 64xLM6 + 32xLM5 + 16xLM4
Threshold Timer Register 0x07
BIT 7
BIT 6
BIT 5
BIT 4
BIT 3
BIT 2
BIT 1
BIT 0
REGISTER
ADDRESS
T7
T6
T5
T4
T3
T2
T1
T0
0x07
If the INTE bit = 1 and the ambient light level exceeds either threshold limit for a time longer than that specified by the
Threshold Timer register, then the INTS bit is set to 1 and the INT pin is pulled low.
The value in this register sets the time used to control this delay. A value of 0x00 in this register (with INTE bit = 1 in the
Interrupt Enable register) configures the IC to assert the interrupt pin as soon as the light level exceeds either threshold.
Time delay = (128xT7 + 64xT6 + 32xT5 + 16xT4 + 8xT3 + 4xT2 + 2xT1 + T0) x 100ms.
Applications Information
Auto and Manual Modes
In auto mode configuration (default setting), CDR and
TIM bits are internally generated. The autoranging circuit
uses two different methods to change its sensitivity. For
light intensities greater than 700 lux, a current divider
reduces the photodiode’s current by a factor of 8. The
default, as in the previous example, is a division of 1:
current goes directly into the I to F converter. As light
intensity decreases, the autoranging circuit increases
the integration time from 100ms to 200ms to 400ms, or
to 800ms. The combination of the current divider and the
different integration times give the A/D a range 8 times
higher, as well as 8 times lower, than its nominal 16-bit
range. This gives a dynamic range of 22 bits or slightly
over 4,000,000 to 1.
In manual mode, the user has access to 4 bits (CDR and
TIM[2:0]) to override the autoranging circuitry. These
affect the integration time of the A/D and the current
division ratio. See the register description for manual
configuration mode (0x02, bit 6).
12
Data Format of Lux Reading
The IC has a user-friendly digital output format. It consists of a 4-bit exponent followed by an 8-bit mantissa.
In its highest sensitivity mode, 1 count represents 0.025
lux. The mantissa has a maximum value of 255, and the
exponent has a maximum value of 14. This gives a maximum range: 255 x 214 = 4,177,920. At 0.025 lux/LSB, the
maximum lux reading is 104,448 lux. Any reading greater
than that (i.e., exponent = 15) is considered to be an
overload. No conversion formulas are needed as in the
case of dual-diode ambient light sensors.
The IC’s output (registers 0x03 and 0x04) comprises a
12-bit result that represents the ambient light expressed
in units of lux.
Here is how lux is calculated:
Lux = (2(exponent) x mantissa) x 0.025
The exponent is a 4-bit number ranging from 0000 to
1110 (zero to 14).
The mantissa is an 8-bit number ranging from 0000 0000
to 1111 1111 (zero to 255).
Maxim Integrated
MAX44007
Low-Power Digital Ambient Light Sensor
with Enhanced Sensitivity
The mantissa is an 8-bit number ranging from 0000 0000
to 1111 0000 (zero to 240).
The count is multiplied by 0.025, which is the LSB.
Because of the logarithmic nature of autoranging circuitry implemented on the IC, resolution of ambient lux
readings scale with the absolute measurement. Table 8
lists the lux resolution and the lux ranges obtained from
the IC.
Upper lux threshold = (2(exponent) x mantissa) x 0.025
The exponent is a 4-bit number ranging from 0000 to
1110 (zero to 14).
The mantissa is an 8-bit number ranging from 0000 1111
to 1111 1111 (15 to 255).
Interrupt Settings
In the auto range mode (MANUAL = 0), the upper threshold and lower threshold bytes must be in a format that
matches the format used in register 0x03, the lux high
byte. There are only two rules to follow:
Interrupt is enabled by setting bit 0 of register 0x01 to
1 (see Table 1). INT, an open-drain output, pulls low
when an interrupt condition occurs (lux readings that
exceed threshold limits for a period greater than that set
by the Threshold Timer register). The interrupt status bit
is cleared automatically if register 0x00 is read or if the
interrupt is disabled (INTE = 0).
• For very low lux levels (light levels below 6.4 lux),
set the exponent to zero, the code is merely: 0000
MMMM where the 4 zeroes are the exponent, and the
MMMM represent the 4 most significant bits of the
mantissa.
Threshold Register Data Format
The IC’s interrupt circuit requires the upper and lower
limit thresholds to be in a specific format to be properly
interpreted. The upper and lower limits, from registers
0x05 and 0x06 must match the lux high-byte format. This
consists of the 4 bits of the exponent and the 4 most significant bits of the mantissa (E3 E2 E1 E0 M7 M6 M5 M4).
• For all other conditions (light levels above 6.4 lux)
where the exponent is not zero, the format is: EEEE
1MMM. Notice that bit M7 (most significant bit) must
always be a 1. The other bits do not matter. EEEE is
limited to a maximum value of 1110. The maximum
usable setting is a code of 1110 1111.
In this case, there is the following formula:
Lower lux threshold = (2(exponent) x mantissa) x 0.025
The exponent is a 4-bit number ranging from 0000 to
1110 (zero to 14).
In manual mode (MANUAL = 1), Table 9 gives the range
of exponent (E3 E2 E1 E0) that can be used for each
TIM[2:0] and CDR bit setting.
Table 8. Lux per LSB in Automatic Mode
LUX (MAX)
LUX PER LSB IN
AUTOMATIC MODE
0
6.4
0.025
0
256
6.4
12.8
0.05
256
512
LUX (MIN)
COUNTS (MIN)
COUNTS (MAX)
12.8
25.6
0.1
512
1024
25.6
51.2
0.2
1024
2048
51.2
102.4
0.4
2048
4096
102.4
204.8
0.8
4096
8192
204.8
409.6
1.6
8192
16,384
409.6
819.2
3.2
16,384
32,768
819.2
1638.4
6.4
32,768
65,536
1638.4
3276.8
12.8
65,536
131,072
3276.8
6553.6
25.6
131,072
262,144
6553.6
13,107.2
51.2
262,144
524,288
13,107.2
26,214.9
102.4
524,288
1,048,576
26,214.4
54,428.8
204.8
1,048,576
2,097,152
52,428.8
104,448.0
409.6
2,097,152
4,177,920
Maxim Integrated
13
MAX44007
Low-Power Digital Ambient Light Sensor
with Enhanced Sensitivity
Table 9. Recommended Manual Mode Settings for Configuration Register (0x02) and
Threshold Registers (0x05, 0x06)
RECOMMENDED SETTINGS
FOR CONFIGURATION
REGISTER (0x03)
APPLICATION CONDITIONS
RANGE OF EXPONENTS FOR
UPPER AND LOWER REGISTERS
(0x05 AND 0x06)
LUX LSB
(MIN)
LUX
(MAX)
LUX LSB
(MAX)
INTEGRATION
TIME (ms)
TIM
CDR
EXPONENT
(MIN)
EXPONENT
(MAX)
0.025
1632
6.4
800
000
0
0000
1000
0.05
3264
12.8
400
001
0
0001
1001
0.1
6528
25.6
200
010
0
0010
1010
100
011
0
800
000
1
0011
1011
0100
1100
0101
1101
0110
1110
0111
1110
0.2
13,056
51.2
0.4
26,112
102.4
0.8
52,224
204.8
1.6
104,448
409.6
3.2
104,448
409.6
50
100
0
400
001
1
25
101
0
200
010
1
12.5
110
0
100
011
1
6.25
111
0
50
100
1
6.4
104,448
409.6
25
101
1
1000
1110
12.8
104,448
409.6
12.5
110
1
1001
1110
25.6
104,448
409.6
6.25
111
1
1010
1110
Note: In manual mode, exceeding the lux (max) causes an overload error (exponent = 1111).
Typical Operating Sequence
To utilize the ultra-low power consumption of the IC in
end applications, an interrupt pin is provided to eliminate
the need for the system to poll the device continuously.
Since every clock and data bit transmitted on I2C can
consume up to 1mA (assuming 1.8kI pullup resistor to
a 1.8V rail), minimizing the number of I2C transactions
on the data bus can save a lot of power. In addition,
eliminating the need to poll the device frees up processing resources for the master, improving overall system
performance.
The typical sequence of communication with the IC is
as follows:
1) Master reads lux reading from registers 0x03 and
0x04.
14
2) Master sets the upper lux threshold and lower lux
threshold in registers 0x05 and 0x06 so that a userprogrammed window is defined around the current
lux readings.
3) Master sets suitable threshold timer data in register
0x07.
4) Master works on other tasks until alerted by the INT
pin going low. This is where the master spends much
of its time.
5) When alerted by the INT pin going low, the master
reads the Interrupt Status register 0x00 to confirm
the source of interrupt was the IC. The master takes
appropriate action.
6) Repeat from Step 1.
Maxim Integrated
MAX44007
Low-Power Digital Ambient Light Sensor
with Enhanced Sensitivity
START
READ MAX44007 AMBIENT LUX,
SET APPROPRIATE BACKLIGHT STRENGTH
WRITE TO UPPER LUX THRESHOLD,
LOWER LUX THRESHOLD AND
LUX THRESHOLD TIMER REGISTERS
WORK ON TASKS/SLEEP UNTIL WOKEN BY
HARDWARE INTERRUPT
WOKEN BY
INTERRUPT?
N
Y
CHECK OTHER INTERRUPT
SOURCES
READ INTS BIT TO CONFIRM
Y
MAX44007 CAUSED
INTERRUPT?
N
Figure 2. Typical Operating Sequence
Maxim Integrated
15
MAX44007
Low-Power Digital Ambient Light Sensor
with Enhanced Sensitivity
I2C Serial Interface
The IC features an I2C/SMBus™-compatible, 2-wire
serial interface consisting of a serial-data line (SDA) and
a serial-clock line (SCL). SDA and SCL facilitate communication between the IC and the master at clock rates
up to 400kHz. Figure 3 shows the 2-wire interface timing
diagram. The master generates SCL and initiates data
transfer on the bus. A master device writes data to the
IC by transmitting the proper slave address followed by
the register address and then the data word. Each transmit sequence is framed by a START (S) or REPEATED
START (Sr) condition and a STOP (P) condition. Each
word transmitted to the IC is 8 bits long and is followed
by an acknowledge clock pulse. A master reading data
from the IC transmits the proper slave address followed
by a series of nine SCL pulses. The IC transmits data on
SDA in sync with the master-generated SCL pulses. The
master acknowledges receipt of each byte of data. Each
read sequence is framed by a START or REPEATED
START condition, a not acknowledge, and a STOP condition. SDA operates as both an input and an open-drain
output. A pullup resistor, typically greater than 500I, is
required on the SDA bus. SCL operates as only an input.
A pullup resistor, typically greater than 500I, is required
on SCL if there are multiple masters on the bus, or if the
master in a single-master system has an open-drain SCL
output. Series resistors in line with SDA and SCL are
optional. Series resistors protect the digital inputs of the
IC from high-voltage spikes on the bus lines, and minimize crosstalk and undershoot of the bus signals.
Bit Transfer
One data bit is transferred during each SCL cycle. The
data on SDA must remain stable during the high period
of the SCL pulse. Changes in SDA while SCL is high are
control signals (see the START and STOP Conditions
section). SDA and SCL idle high when the I2C bus is not
busy.
START and STOP Conditions
SDA and SCL idle high when the bus is not in use. A
master initiates communication by issuing a START condition. A START condition is a high-to-low transition on
SDA with SCL high. A STOP condition is a low-to-high
transition on SDA while SCL is high (Figure 4). A START
condition from the master signals the beginning of a
transmission to the IC. The master terminates transmission, and frees the bus, by issuing a STOP condition. The
bus remains active if a REPEATED START condition is
generated instead of a STOP condition.
Early STOP Conditions
The IC recognizes a STOP condition at any point during
data transmission except if the STOP condition occurs in
the same high pulse as a START condition. For proper
operation, do not send a STOP condition during the
same SCL high pulse as the START condition.
SDA
tSU,STA
tSU,DAT
tHD,DAT
tLOW
tBUF
tHD,STA
tSP
tSU,STO
SCL
tHIGH
tHD,STA
START
CONDITION
tR
tF
REPEATED
START CONDITION
STOP
CONDITION
START
CONDITION
Figure 3. 2-Wire Interface Timing Diagram
SMBus is a trademark of Intel Corp.
16
Maxim Integrated
MAX44007
Low-Power Digital Ambient Light Sensor
with Enhanced Sensitivity
S
SR
P
CLOCK PULSE FOR
ACKNOWLEDGMENT
START
CONDITION
SCL
SCL
1
2
8
9
NOT ACKNOWLEDGE
SDA
SDA
ACKNOWLEDGE
Figure 4. START, STOP, and REPEATED START Conditions
Figure 5. Acknowledge
Slave Address
The slave address with the R/W bit set to 0 indicates
that the master intends to write data to the IC. The IC
acknowledges receipt of the address byte during the
master-generated ninth SCL pulse.
Acknowledge
The second byte transmitted from the master configures
the IC’s internal register address pointer. The pointer
tells the IC where to write the next byte of data. An
acknowledge pulse is sent by the IC upon receipt of the
address pointer data.
The slave address is controlled by the A0 pin. Connect
A0 to either ground or VCC to set the address. Table 10
shows the two possible addresses for the IC.
The acknowledge bit (ACK) is a clocked 9th bit that the
IC uses to handshake receipt each byte of data when in
write mode (see Figure 5). The IC pulls down SDA during the entire master-generated ninth clock pulse if the
previous byte is successfully received. Monitoring ACK
allows for detection of unsuccessful data transfers. An
unsuccessful data transfer occurs if a receiving device
is busy or if a system fault has occurred. In the event of
an unsuccessful data transfer, the bus master can retry
communication. The master pulls down SDA during the
ninth clock cycle to acknowledge receipt of data when
the IC is in read mode. An acknowledge is sent by the
master after each read byte to allow data transfer to
continue. A not acknowledge is sent when the master
reads the final byte of data from the IC, followed by a
STOP condition.
Write Data Format
A write to the IC includes transmission of a START condition, the slave address with the R/W bit set to 0, one byte
of data to configure the internal register address pointer,
one or more bytes of data, and a STOP condition. Figure
6 illustrates the proper frame format for writing one byte
of data to the IC.
The third byte sent to the IC contains the data that is written to the chosen register. The master signals the end of
transmission by issuing a STOP condition.
Read Data Format
To read a byte of data, the register pointer must first be
set through a write operation (Figure 7). Send the slave
address with the R/W set to 0, followed by the address
of the register that needs to be read. After a repeated
start condition, send the slave address with the R/W bit
set to 1 to initiate a read operation. The IC then sends
an acknowledge pulse followed by the contents of the
register to be read. Transmitted data is valid on the rising
edge of the master-generated serial clock (SCL).
Sensor Position
The photo sensitive area of the IC is 0.37mm x 0.37mm
and much smaller than the device itself. When placing
the part behind a light guide, only this sensitive area has
to be taken into account. Figure 8 shows the position and
size of the photo sensitive area within the package.
Table 10. Slave Address
A0
SLAVE ADDRESS FOR WRITING
GND
1011 0100
1011 0101
VCC
1011 0110
1011 0111
Maxim Integrated
SLAVE ADDRESS FOR READING
17
MAX44007
Low-Power Digital Ambient Light Sensor
with Enhanced Sensitivity
ACKNOWLEDGE FROM MAX44007
B7
ACKNOWLEDGE FROM MAX44007
SLAVE ADDRESS
S
B6
B5
B4
B3
B2
B1
B0
ACKNOWLEDGE FROM MAX44007
0
REGISTER ADDRESS
A
A
DATA BYTE
A
R/W
P
1 BYTE
Figure 6. Writing 1 Byte of Data to the IC
NOT ACKNOWLEDGE FROM MASTER
ACKNOWLEDGE FROM MAX44007
S
SLAVE ADDRESS
0
ACKNOWLEDGE FROM MAX44007
A
REGISTER ADDRESS
ACKNOWLEDGE FROM MAX44007
A
Sr
SLAVE ADDRESS
A
R/W
REPEATED START
R/W
1
DATA BYTE
A
P
1 BYTE
Figure 7. Reading One Indexed Byte of Data from the IC
VCC
0.76mm
2mm
1
MAX44007
6
SDA
5
SCL
4
INT
TOP VIEW
AO
2
3
CENTER OF
MAX44007
0.24mm
0.13mm
0.88mm
0.87mm
GND
2mm
0.75mm
0.12mm
0.25mm
Figure 8. Sensor Position
18
Maxim Integrated
MAX44007
Low-Power Digital Ambient Light Sensor
with Enhanced Sensitivity
Typical Application Circuit
VCC TO 3.6V
1.7V TO 3.6V
0V TO VCC
1µF
10kI
10kI
10kI
VCC
SDA
SDA
GND
SCL
SCL
A0*
INT
INT
MAX44007
*DEVICE ADDRESS IS 1011 010x. CONNECT
A0 TO VCC FOR SLAVE ADDRESS 1011 011x.
SEE THE PIN DESCRIPTION.
SDA
SDA
SCL
SCL
I2C SLAVE_1
I2C SLAVE_n
MICROCONTROLLER
(I2CMASTER)
Chip Information
PROCESS: BiCMOS
Maxim Integrated
19
MAX44007
Low-Power Digital Ambient Light Sensor
with Enhanced Sensitivity
Package Information
For the latest package outline information and land patterns (footprints), go to www.maxim-ic.com/packages. Note that a “+”, “#”,
or “-” in the package code indicates RoHS status only. Package drawings may show a different suffix character, but the drawing
pertains to the package regardless of RoHS status.
20
PACKAGE TYPE
PACKAGE CODE
OUTLINE NO.
LAND PATTERN NO.
6 UTDFN-Opto
D622N+1
21-0490
90-0344
Maxim Integrated
MAX44007
Low-Power Digital Ambient Light Sensor
with Enhanced Sensitivity
Revision History
REVISION
NUMBER
REVISION
DATE
0
11/10
Initial release
1
6/11
Added Guaranteed by design note and changed lux level specs in Electrical
Characteristics; Table7.
DESCRIPTION
PAGES
CHANGED
—
1, 2, 3, 6,
10, 11, 12
Maxim cannot assume responsibility for use of any circuitry other than circuitry entirely embodied in a Maxim product. No circuit patent licenses are implied.
Maxim reserves the right to change the circuitry and specifications without notice at any time. The parametric values (min and max limits) shown in the Electrical
Characteristics table are guaranteed. Other parametric values quoted in this data sheet are provided for guidance.
Maxim Integrated 160 Rio Robles, San Jose, CA 95134 USA 1-408-601-1000
© Maxim Integrated
21