NG5N
20.5×7.2×15.3 Features Small size, light weight. Switching capacity up to 5A. Low coil power consumption 0.2W.
Suitable for household electrical appliance, automation system, electronic equipment, instrument, meter, telecommunication facilities and remote control facilities.
Ordering Information
NG5N A DC12V
1 2 3 1 Part number:NG5N 2 Contact Arrangement:A:1A 3 Coil rated Voltage(V):DC:3,5,6,9,12,18,24
Contact Data
Contact Arrangement Contact Material Contact Rating (resistive) Max. Switching Power Max. Switching Voltage Contact Resistance or Voltage drop Operation Electrical life Mechanical 1A SPSTNO Silver Alloy 5A/30VDC,250VAC 150W 1250VA 30VDC 250VAC 100m 105 107
min Switching load:10mA/5V Max. Switching Current:5A Item 3.12 of IEC255-7 Item 3.30 of IEC255-7 Item 3.31 of IEC255-7
CAUTION:
Relays previously tested or used above 10mA resistive at 6VDC maximum or peak AC open circuit are not recommended for subsequent use in low level applications.
Coil Parameter
Coil voltage VDC Coil resistance ±10% Max. 3.9 6.5 7.8 11.7 15.6 23.4 31.2 45 125 180 405 720 1620 2880 Pickup voltage VDC(max) (75%of rated voltage ) 2.25 3.75 4.50 6.75 9.00 13.5 18.0 release voltage VDC(min) (10% of rated voltage) 0.3 0.5 0.6 0.9 1.2 1.8 2.4 0.2
10
4 Coil power consumption W Operate Time ms Release Time ms
Dash Numbers
Rated 003-200 005-200 006-200 009-200 012-200 018-200 024-200 3 5 6 9 12 18 24
CAUTION: 1.The use of any coil voltage less than the rated coil voltage will compromise the operation of the relay.
2.Pickup and release voltage are for test purposes only and are not to be used as design criteria.
41
www.dblectro.com
NG5N
Operation condition
Insulation Resistance Dielectric Strength Between contacts Between contact and coil Shock resistance Vibration resistance Terminals strength Solderability Ambient Temperature Relative Humidity Mass 1000M min (at 500VDC) Item 7 of IEC255-5 Item 6 of IEC255-5 Item 6 and 8 of IEC255-5 IEC68-2-27 Test Ea IEC68-2-6 Test Fc IEC68-2-21 Test Ua1 IEC68-2-20 Test Ta method 1 IEC68-2-3Test Ca
50Hz 750V 50Hz 4000V surge voltage:7kV Functional:100m/s2 11ms Survival:1000m/s2 6ms 10~50Hz Functional & Survival double amplitude 1.5mm 5N 235x2 3x0.5s -30~70 20%~85% (at 40) 4g
Qualification inspection:
Perform the qualification test as specified in the table of IEC255-19-1 and minimum sample size 24.
Dimensions (Unit: mm)
mm 0.27 0.52 0.8 1.05 1.1 1.2 3.4 4.7 7 7.2 11.5 15.3 20.5
>àçÇá
Mounting (Bottom views)
Dimensions
0.011 0.020 0.031 0.041 0.043 0.047 0.134 0.185 0.275 0.283 0.453 0.602 0.807
Wiring diagram (Bottom views)
NOTES 1).Dimensions are in millimeter.
2).Inch equivalents are given for general information only.
www.dblectro.com
很抱歉,暂时无法提供与“NG5NADC5V”相匹配的价格&库存,您可以联系我们找货
免费人工找货