Présente / Presents:
DB LECTRO Inc. 3755 Place Java, Suite 140, Brossard, Québec, J4Y 0E4, Canada - T: 1-450-444-1424 / F: 1-450-444-4714 / www.dblectro.com
NT90TP (T92)
NT90TP (T92)
03001003503
R
E9930952
32.4(50)
27
20
32.4(50) 27
28.5
R2033977.07 C US E160644 Patent No.02110881.1
Features
S mall size, light weight. Low coil power consumption, heavy contact load. Strong anti-shock and anti-vibration, high reliability, long life. Suitable for automobile, machine, electronic equipment, air conditioner and household appliances applications.
Ordering Information
N90TP
1 1 2 3 4 5
H
2
L
3
AS
4 5
DC12V
6
C
7
B
8
0.9
9
Part number NT90TP T92 NT90TP 2 Load H:30A N:40A High NIL: Standard L: Low profile type Contact arrangement A:1A B:1B C:1C Enclosure S: Sealed type D: Dust cover E: Covered
6 Coil rated Voltage(V) AC:12,24, 110,120,220 DC:3,5,6,9,12,15,18,24,48,110 7 Contact material C: AgCdO S: AgSnO2 ; I: AgSnO2 In 2O 3 8 Resist heat class B:130 F:155 9 Coil power consumption 0.6:0.6W 0.9:0.9W NIL:2VA
Contact Data
Contact Arrangement Contact Material Contact Rating (resistive) 1A SPSTNO 1B SPSTNC 1C AgCdO AgSnO2 AgSnO2In 2O 3 SPDT(B-M)
NO:30A/240VAC,14VDC; NC:20A/240VAC;30A/14VDC NO:40A/250VAC,30VDC; NC:30A/250VAC,30VDC (0.9W) NO:30A/277VAC;NC:20A/277VAC Motor load 2HP 250VAC 1.5HP 250V Lamp load TV-5
Max. Switching Power Max. Switching Voltage Contact Resistance or Voltage drop Operation Electrical life Mechanical
1100W 7200VA 110VDC 250VAC 30m 105 107
Max. Switching Current:40A Item 3.12 of IEC255-7 Item 3.30 of IEC255-7 Item 3.31 of IEC255-7
C oil Parameter
AC Coil Parameter Rated voltage VAC Rated current mA Pick up voltage VAC(max) (75%of rated voltage) 9.0 18.0 82.5 90.0 165.0 Release voltage VAC(min) (30%of rated voltage) 3.6 7.2 33.0 36.0 66.0
Dash numbers
Coil resistance 10%
Coil power
Operate Time ms
Release Time ms
Rated 012AC 024AC 110AC 120AC 220AC 12 24 110 120 220
Max 15.6 31.2 143 156 286 187 95 20 16.5 6.4 27 120 2360 3040 13490
2VA
CAUTION: 1.The use of any coil voltage less than the rated coil voltage will compromise the operation of the relay.
2.Pickup and release voltage are for test purposes only and are not to be used as design criteria.
Ningbo Huaguan Relay Corporation LTD.
NHG RELAYS
C oil Parameter
DC Coil Parameter Rated voltage VDC Rated 003-900 005-900 006-900 009-900 012-900 015-900 018-900 024-900 036-900 048-900 110-900 3 5 6 9 12 15 18 24 36 48 110 Max 3.9 6.5 7.8 11.7 15.6 19.5 23.4 31.2 46.8 62.4 143 Pick up voltage VDC(max) (75%of rated voltage) 2.25 3.75 4.50 6.75 9.00 10.25 13.50 18.00 27.00 36.00 82.50 Release voltage VDC(min) (10%of rated voltage) 0.3 0.5 0.6 0.9 1.2 1.5 1.8 2.4 3.6 4.8 11.0
Dash numbers
Coil resistance 10%
Coil power W
Operate Time ms
Release Time ms
10 28 40 90 160 250 360 640 1440 2560 13445
0.9
15
10
003-600 005-600 006-600 009-600 012-600 015-600 018-600 024-600 048-600 110-600
3 5 6 9 12 15 18 24 48 110
3.9 6.5 7.8 11.7 15.6 19.5 23.4 31.2 62.4 143
15 42 60 135 240 375 540 960 3840 20167
2.25 3.75 4.50 6.75 9.00 10.25 13.50 18.00 36.00 82.50
0.3 0.5 0.6 0.9 1.2 1.5 1.8 2.4 4.8 11.0
0.6
15
10
CAUTION: 1.The use of any coil voltage less than the rated coil voltage will compromise the operation of the relay.
2.Pickup and release voltage are for test purposes only and are not to be used as design criteria.
Operation condition
Insulation Resistance Dielectric Strength Between contacts Between contact and coil Shock resistance Vibration resistance Terminals strength Solderability Ambient Temperature Relative Humidity Mass 1000M min (at 500VDC) Item 7 of IEC255-5 Item 6 of IEC255-5 Item 6 of IEC255-5 IEC68-2-27 Test Ea IEC68-2-6 Test Fc IEC68-2-21 Test Ua2 IEC68-2-20 Test Ta method 1 IEC68-2-3 Test Ca
50Hz 1500V 50Hz 2500V 200m/s 11ms 10~55Hz double amplitude 1.5mm 10N 235 2 3 0.5s -55~100 -55~125 85% (at 40 ) 35g Low profile type 37g
2
Qualification inspection:
Perform the qualification test as specified in the table of IEC255-19-1 and minimum sample size 24.
Safety approvals
Safety approval UL&CUR NO:40A/240VAC 30A/277VAC NC:30A/240VAC 20A/277VAC 2HP 250VAC TV-5 1 1 HP 250VAC 2 HP:A 1HP/16AFLA/120VAC 2HP/12AFLA/240VAC B 30LRA/10AFLA/120VAC 30LRA/10AFLA/240VAC Insulation B-class F-class TV NO:40A/240VAC 14VDC NC:30A/240VAC 14VDC Insulation B-class F-class CQC NO:30A/240VAC NC:20A/240VAC
Load
NT90TP (T92)
D imensions
43.5
1.713
mm /inch
2-0.5x2.8
0.020 0.110
43.5
1.713
15.4 2-R1.8
R0.071 0.401 0.606
2-0.5x2.8
0.020 0.110
15.4 2-R1.8
R0.071 0.606
10.2
7.8
0.142
3.6
0.150 0.008
3.8 0.2
0.252
0.142
0.110
3.8 0.2
0.150
0.704
0.110
0.303
17.9
0.704
2.8
0.110
2.8
6.4
7.7
0.110
17.9
2.8
0.252
0.303
0.008
2.8
6.4
7.7
3.6
COM
7.8
NO
NC
0.307
COM
0.401
NO
NC
0.307
10.2
32.5Max. 1.280max.
27.5 Max. 1.063max.
32.5Max. 1.280max.
0.787max. 0.307
27.5Max. 1.063max. 20Max. 7.8
0.079 28 Max.
1.102max.
50.2
1.976max.
NT90TP
0.007
50.2Max. 1.976max.
43.5
1.713
10.2 0.2
NC
2-0.5X4.8
0.020 0.315 R0.071
12.3 0.2
0.484 0.007
0.401
N0 COM
3-6.4X0.8
15.4 0.2
0.606 0.007 0.303
3.6
0.142
15.4 0.2
0.007
0.189
NT90TP 2
NC NC
2.8
0.110
7.7 0.2
0.007
N0 COM COM
N0 COM
32.5Max. 1.280max.
0.252
0.031
2-R1.8
0.087
2.2
2
27.5 Max. 1.083max.
28.2 Max.
NT90TP Wiring diagram NOTES 1). Dimensions are in millimeters. 2). Inch equivalents are given for general information only.
50.2Max. 1.976max.
NT90TP2 Dimensions
Reference Data
12 10 8 6 4
Time (m sec)
Ningbo Huaguan R elay Corporation LTD.
0.087
2.2
1.110max.