0
登录后你可以
  • 下载海量资料
  • 学习在线课程
  • 观看技术视频
  • 写文章/发帖/加入社区
会员中心
创作中心
发布
  • 发文章

  • 发资料

  • 发帖

  • 提问

  • 发视频

创作活动
06AR2D

06AR2D

  • 厂商:

    DELTA(台达)

  • 封装:

    Module

  • 描述:

    PWR ENT MOD RCPT IEC320-C14 PNL

  • 数据手册
  • 价格&库存
06AR2D 数据手册
V D E SERIES POWER ENTRY MODULE EMI FILTERS INTRODUCTIONS SPECIFICATIONS 1. AR series is designed as a high performance, two-stage filter for low impedance load with better noise attenuation than AK series in low frequency applications such as switching power supplies. 2. Fuse holder designed for one IEC 5x20mm fuse. Safety interlock prevents fuse removal with line plug inserted (Use only with 250V fuse). 3. All part numbers are UL recognized, CSA certified and VDE approved. 4. Switch electrical lifetime: 10,000 cycles. 1. Maximum leakage current each line-to-ground @ 115VAC 60Hz: 0.25mA @ 250VAC 50Hz: 0.45mA 2. Hipot rating (one minute) line-to-ground: 2250VDC line-to-line: 1450VDC 3. Operating frequency: 50/60Hz 4. Rated voltage: 115/250VAC Maximum inrush current: 50A. COMPONENTS PART NO. 03AR1/2/3 03AR2D/3D 06AR1/2/3 06AR2D/3D 06AR4 MINIMUM INSERTION LOSS IN dB C1 (uF) L1 (mH) L2 (mH) Cy (pF) 0.1 1.5 9 2200 0.033 9 1.5 0.1 0.7 2.5 0.015 2.5 0.7 3300 0.1 0.7 2.5 COMMON MODE (L-G) IN 50 OHM SYSTEM CURRENT FREQUENCY-MHz RATING .15 .50 1.0 5.0 10 03AR 40 60 60 45 40 06AR 34 55 56 40 35 06AR2D,3D 34 60 60 45 40 DIFFERENTIAL MODE (L-L) IN 50 OHM SYSTEM 03AR 6 45 55 50 45 06AR 5 25 60 50 45 06AR2D,3D 10 10 50 50 45 R( ) 1M 2.2M 30 30 25 30 40 35 40 ELECTRICAL SCHEMATIC AR3/4 ONLY AR3D ONLY L' L L F SW1 Cy C1 R C2 C3 I L' L L L F SW1 O L1 E N G A E G' FIG. B C3:0.1uF TYPE & RATED CURRENT DELTA PART NO. 115VAC RATED CURRENT 250VAC IEC CONNECTOR FUSE HOLDER POWER SWITCH VOLTAGE SELECTOR SW ELECTRICAL SCHEMATIC AR1 6A 6A FIG. A C3 L2 Cy N G FIG. A C2:0.1uF R C2 AR2 6A 6A AR2D 6A 4A AR3 6A 6A AR3D 6A 4A AR4 6A 6A SP1 DP2 FIG. A FIG. B SP1 REAR3 FIG. A DP2 REAR3 FIG. B REAR3 FIG. A 1. Single-pole UL, CSA & VDE approved, VDE-6A at 250VAC. 2. Double-pole UL, CSA & VDE approved, VDE-4A at 250VAC. Electrical lifetime: 10,000 cycles. Maximum inrush current: 50A. 3. Voltage selector SW -UL, CSA & VDE approved Current rating: 10A at 125VAC; 5A at 250VAC. 4-3 L O L1 N N' D Cy C1 I L2 N Cy A N' D G' POWER ENTRY MODULE FILTERS AR1/4 WITHOUT POWER SW Suggested thickness of mounting panel is from 0.04 to 0.07 inch suggest mounting cutout 27.0 1.063 0.003 R0.04Max. 1.0 2.6 0.003 66.0 2.65 67.3 O G N I L 2.17 55.1 2.38 60.5 1.15 29.2 MECHANICAL CONSTRUCTION 2.57 65.3 1.059 26.9 N G L AR2, AR2D O G N I L AR3, AR3D AR4(without power switch) 0.65 16.5 115V G 1.059 26.9 29.2 1.15 2.65 67.3 G N L 2.17 55.1 2.24 56.9 POWER ENTRY MODULE FILTERS 2.60 66.0 1.15 29.2 2.65 67.3 G AR1 2.57 65.3 4-4 1.059 26.9 UNIT: INCH mm
06AR2D 价格&库存

很抱歉,暂时无法提供与“06AR2D”相匹配的价格&库存,您可以联系我们找货

免费人工找货