NB SB SERIES
SPECIFICATIONS
INTRODUCTIONS
1. Maximum leakage current each
line-to-ground @ 115VAC 60Hz: 2uA
@ 250VAC 50Hz: 5uA
2. Hipot rating (one minute)
line-to-ground: 2250VDC
line-to-line: 1450VDC
3. Operating frequency: 50/60Hz
4. Rated voltage: 115/250VAC
1. Applications for UL 544 & UL 2601 health care equipment.
2. Power module incorporates an IEC connector, single or doublefuse (IEC 5x20mm) holder, and double-pole power switch, plus
an EMI filter all-in-one easy-to-install unit.
COMPONENTS
PART NO. C1 (uF) L (mH) R (Ohm)
03NB3M
2.5
03NB4M
04NB3M
2.0
04NB4M
06NB3M
1.05
06NB4M
ELECTRICAL SCHEMATIC
F
SW
R
L
I
N
E
L
O
A
D
Cx
L
B
0.1
110V-120V
2
A
CUSTOMER
TRANSFORMER
PRIMARIES
D
C
3
N
0.2
1
L
10NB3M
10NB4M
03SB3M
03SB4M
V
D E
POWER ENTRY MODULE FILTERS
1.0
G
G
4
110V-120V
1
110V-120V
FIG. A
NB3,SB3
2.5
04SB3M
04SB4M
2.0
06SB3M
06SB4M
10SB3M
10SB4M
F
L
R
L
I
N
E
1.05
L
O
A
D
Cx
L
B
2
A
CUSTOMER
TRANSFORMER
PRIMARIES
D
C
3
N
G
0.2
G
4
110V-120V
FIG. B
VDE approved 6A to 250VAC
NB4,SB4
TYPE & RATED CURRENT
DELTA PART NO.
RATED CURRENT
03NB3M/SB3M 04NB3M/SB3M 06NB3M/SB3M 10NB3M/SB3M 03NB4M/SB4M 04NB4M/SB4M 06NB4M/SB4M 10NB4M/SB4M
115VAC
3A
4A
6A
10A
3A
4A
6A
10A
250VAC
3A
4A
6A
6A
3A
4A
6A
6A
DOUBLE
DOUBLE
DOUBLE
DOUBLE
DOUBLE
DOUBLE
DOUBLE
DOUBLE
-
-
-
FIG. B
FIG. B
FIG. B
IEC CONNECTOR
FUSE
*DOUBLE-POLE POWER SWITCH
ELECTRICAL SCHEMATIC
FIG. A
FIG. A
FIG. A
FIG. A
FIG. B
3S,4S Fuse single
NB4,SB4 W/O Switch
* UL,CSA,VDE approved current rating: UL/CSA-10A
Electrical lifetime: 10,000 cycles.
Maximum inrush current: 51A
MINIMUM INSERTION LOSS IN dB
COMMON MODE (L-G) IN 50 OHM SYSTEM
CURRENT
FREQUENCY-MHz
RATING
.15
.50
1.0
5.0
10
03NB3M/SB3M
20
25
25
25
20
03NB4M/SB4M
20
25
25
25
20
04NB3M/SB3M
20
22
25
25
20
04NB4M/SB4M
20
22
25
25
20
06NB3M/SB3M
12
15
15
20
20
06NB4M/SB4M
12
15
15
20
20
10NB3M/SB3M
5
10
10
10
10
10NB4M/SB4M
5
10
10
10
10
30
10
10
10
10
12
12
7
7
COMMON MODE (L- L) IN 50 OHM SYSTEM
CURRENT
FREQUENCY-MHz
RATING
.15
.50
1.0
5.0
10
03NB3M/SB3M
4
12
15
25
25
03NB4M/SB4M
4
12
15
25
25
04NB3M/SB3M
5
10
18
25
25
04NB4M/SB4M
5
10
18
25
25
06NB3M/SB3M
3
10
15
20
25
06NB4M/SB4M
3
10
15
20
25
10NB3M/SB3M
4
10
15
22
22
10NB4M/SB4M
4
10
15
22
22
7-8
30
20
20
20
20
20
20
20
20
32.0
4.0
28.0
46.0
MECHANICAL CONSTRUCTION
54.0
58.0
220 -240V
USE ONLY WITH 250V
FUSE/EMPLOYER
UNIQUEMENT AVEC
DES FUSIBLES DE 250V
110 - 120V
41.0
2.0
51.3
3.0
+0.2
28.5-0
.0
55.0
+0.2
L -0
R2
R0.5
(2X)
28.4 MAX.
SUGGESTED MOUNTING CUTOUT
(MOUNTING FROM FRONT)
According to panel thickness:
0.8~2.0mm L=55.9
2.1~3.2mm L=56.2
NB3
32.0
46.0
28.0
54.0
58.0
220 -240V
USE ONLY WITH 250V
FUSE/EMPLOYER
UNIQUEMENT AVEC
DES FUSIBLES DE 250V
110 - 120V
41.0
2.0
51.3
3.0
28.5+0.2
-0
R2
55.0
+0.2
L -0
.0
R0.5
(2X)
28.4 MAX.
SUGGESTED MOUNTING CUTOUT
(MOUNTING FROM FRONT)
NB4
According to panel thickness:
0.8~2.0mm L=55.9
2.1~3.2mm L=56.2
50.0
40.01 0.5
28.0
4.0
46.0
54.0
58.0
220 -240V
USE ONLY WITH 250V
FUSE/EMPLOYER
UNIQUEMENT AVEC
DES FUSIBLES DE 250V
110 - 120V
2.0
41.0
51.3
40.01 0.1
3.0
+0.2
28.5-0
55.9+0.2
-0
55.0
R2
.0
M3
28.4 MAX.
SB3, 3S
SUGGESTED MOUNTING CUTOUT
(MOUNTING FROM FRONT)
50.0
40.01
0.5
28.0
46.0
54.0
58.0
220 -240V
USE ONLY WITH 250V
FUSE/EMPLOYER
UNIQUEMENT AVEC
DES FUSIBLES DE 250V
110 - 120V
2.0
41.0
51.3
40.01 0.1
3.0
28.5+0.2
-0
SB4
.0
UNIT: INCH
mm
55.9+0.2
-0
55.0
R2
M3
28.4 MAX.
7-9
SUGGESTED MOUNTING CUTOUT
(MOUNTING FROM FRONT)
很抱歉,暂时无法提供与“10NB4M”相匹配的价格&库存,您可以联系我们找货
免费人工找货- 国内价格
- 1+244.79280
- 192+97.67520
- 480+94.41360
- 960+92.80440