AA30S/D/T Series
30W Single, Dual, and Triple Output AC-DC Power Module
FEATURES
Encapsulated compact AC-DC power supply
Single-, Dual, and Triple Output Models
Over Load and Over Voltage Protection
3 Mounting Package Versoin:
- Solder pins for direct PCB mount
- Screw terminal block for chassis mount
- DIN-Rail Mounting
Universal Input voltage range 85-264 VAC,
47-440 Hz
3kVAC Isolatoin, Protection Class ll level
UL/UL/IEC/EN 60950-1 Certified , CE Marked
UL508 Approval (Selective)
Lead free, RoHs Compliant
3 Year Product Warranty
The AA30S/D/T series , isolated fully encapsulated 30W AC/DC power module with 3,000VAC isolation. With Universal input voltage
85-264VAC and International safety approvals, these power modules are ideal for applications in commercial and industrial electronic
equipment. These isolated AC/DC converters are the latest offering from a world leader in power systems technology and
manufacturing ― Delta Electronics, Inc. With creative design technology and optimization of component placement, these converters
possess outstanding electrical and thermal performance, as well as extremely high reliability under highly stressful operating
conditions. industrial electronic equipment
Model List
Model Number
AA30S0500A
AA30S1200A
AA30S1500A
AA30S2400A
AA30S4800A
AA30D1212A
AA30D1515A
AA30D0512A
AA30T051212A
AA30T121205A
AA30T051515A
AA30T050312A
AA30T030512A
DS_AA30S_06172014
Output
Voltage
Output Current
Input Current
115VAC, 60Hz
VDC
5
12
15
24
Max.
mA
6000
2500
2000
1250
Peak
mA
---------
@Max. Load
mA(typ.)
557
543
543
543
@No Load
mA(typ.)
60
60
60
60
48
625
---
543
60
565
543
60
60
572
60
572
60
572
60
572
60
588
60
483
60
±12
±1300
--±15
±1000
--*5
3000
4500
*12
1250
1800
*5
3000
4500
12
600
900
-12
-600
900
*5
3000
4500
12
1000
1500
-12
-250
500
*5
3000
4500
15
500
750
-15
-500
750
*5
4500
6000
+3.3
1000
1500
+12
250
500
*3.3
4000
5300
+5
1500
2000
+12
250
500
* Output floating (note 6)
Max. capacitive
Load
Efficiency
(typ.)
μF
8000
3900
3900
1500
@Max. Load
%
78
80
80
80
1000
*1500
*1500
3900
1500
2200
1500
1500
2200
1500
1500
2200
1500
1500
2200
2200
1500
2200
2200
1500
* For each output
UL60950-1 UL508
Approval Approval
○
○
○
○
○
○
○
○
80
○
○
80
80
○
○
76
○
76
○
76
○
76
○
71
○
71
○
E-mail: DCDC@delta.com.tw
http://www.deltaww.com/dcdc
P1
Input Characteristics
Parameter
Input Voltage Range
Input Frequency Range
Input Voltage Range
Model
Min.
85
47
120
-----
All Models
115VAC
230VAC
Inrush Current (Cold Start at 25℃)
Typ.
-----------
Max.
264
440
370
20
40
Unit
VAC
Hz
VDC
A
A
Output Characteristics
Parameter
Conditions
Single / Dual Output
Output Voltage Accuracy
Line Regulation
Load Regulation
Cross RegulationDual / Triple Output
Models
Vo1
Vo2&Vo3
Dual Positive / Triple Output
Iout=Min. to Max.
Vo1
Vo2
Vo3
Vin=Min. to Max.
Single Output Models
Dual Output Models
Vo1
Triple Output
Models
Vo2&Vo3
Measured output Io = 20% to 100% of rated load
Other output(s) set at 50% of rated load
3.3V & 5VDC Output Models
Other Output Models
Single-,Dual-Output Models and Main Output Triple
Output Models
Auxiliary Outputs of Triple Output Models
Zener diode clamp
Ripple & Noise (20MHz)
Minimum Load
Over Voltage Protection
Temperature Coefficient
Overshoot
Min.
---------------------------
Typ.
±1.0
±1.0
±3.0
±0.2
±0.5
±2.5
±2.5
±4.0
±2.0
±5.0
±5.0
1.5
1.0
Max.
±2.0
±2.0
--±1.0
±1.0
±5.0
±5.0
--------1.8
1.3
Unit
%
%
%
%
%
%
%
%
%
%
%
%VPP of Vo
%VPP of Vo
---
10
---
%Inom.
---------
20
120
±0.02
---
------5
%Inom.
% of Vo
%/℃
% Vout
---
% Inom.
Foldback, auto-recovery
105
--(long term overload condition may cause damage)
Hiccup mode, indefinite (automatic recovery)
Current Limitation
Short Circuit Protection
General Characteristics
Parameter
I/O Isolation Voltage
I/O Isolation Resistance
Switching Frequency
Hold-up Time
MTBF (calculated)
EMC Emission
Conditions
Input to Output, 60 Seconds
500 VDC
MIL-HDBK-217F@25℃, Ground Benign
Conducted and radiated
Standard
EN61000-4-2
EN61000-4-3
EN61000-4-4
EMC Immunity according
EN61000-6-1
EN61000-4-5
EN61000-4-6
EN61000-4-8
EN61000-4-11
Protection Class II
Safety Approvals
Min.
Typ.
Max.
Unit
3000
----VACrms
100
----MΩ
--100
--KHz
--20
--ms
200,000
----Hours
EN 55011 class B, EN 55022 class B, FCC part 15 class B
Specification Requirement
Performance Criteria
B
Air ±8KV Cont. ±4KV
80~1000MHz, 10V/m 80% AM, 1KHz
A
modulation
AC port ±2KV DC, SL, TL ±2KV not less than
B
1 min.
B
1.2/50uS(8/20μS) AC dif. ±1KV DC ±0.5KV
0.15~80MHz, 10Vrms (functional earth ports
included)
B
80% AM, 1KHz modulation
A
50Hz/60Hz, 30A/m
B
30%, 10ms
C
60%, 100ms, 95%, 5000ms
According IEC/EN 60536
cUL/UL 60950-1,IEC/EN 60950-1
UL508 for selective models
Recommended Input Fuse
All Models
Built-in Fuse
External Fuse (Recommended)
DS_AA30S_06172014
3.5A / 250VAC
1.5A Slow – Blow Type
E-mail: DCDC@delta.com.tw
http://www.deltaww.com/dcdc
P2
Environmental Specifications
Parameter
Temperature Range (operational)
Storage Temperature Range
Over Temperature Protection
Cooling
Humidity (non condensing)
Ambient
Conditions
-25℃
-40℃
at 90℃ (automatic recovery at 67℃)
Free-Air convection
---
+70℃
+85℃
95 % rel. H
Power Derating Curve
Notes
1
2
3
4
5
6
7
All specifications typical at Ta=+25℃, resistive load, 115VAC, 60Hz input voltage and after warm-up time rated output current unless
otherwise noted.
Ripple & Noise measurement bandwidth is 0~20 MHz
These power modules require a minimum output loading to maintain specified regulation, operation under no-load conditions will not
damage the power supplies however they may not meet all listed specifications.
Other input and output voltage may be available, please contact us for custom solution
Peak current can't be drawn from all output at the same time.
Floating (or isolated) output of a power supply that is not connected to any other output.
Specifications are subject to change anytime without notice
DS_AA30S_06172014
E-mail: DCDC@delta.com.tw
http://www.deltaww.com/dcdc
P3
Mechancial Drawing PCB Mounting
Mechanical Dimensions
Pin Connections
21.7 [0.85]
6.0 [0.24]
15.24
[0.60]
15.24
[0.60]
12.7
[0.50]
12.7
[0.50]
Pin
Dual
(±12, ±
15)
Single
0.7 [0.03]
Dual
(0512)
5
6
4
1.0 [ 0.04]
1
7
3
26.75 [1.05]
AC(L) – AC Line
+Vo
ut
3
5
88.9 [3.50]
81.3 [3.20]
27.5 [1.08]
No Pin
6
Commo
n
No Pin
NC
+Vout2
+Vout2
+Vout2
+Vout1
+Vout1
+Vout1
-Vout2
Com.
2/3
Com. 2/3
-Vout1
-Vout1
-Vout1
NC
-Vout3
+Vout3
-Vout
1
5.0 [0.20]
NC: No Connection
31.45 [1.24]
2
+Vout
-Vou
t
7
Bottom View
Triple
(050312, 030512)
AC(N) – AC Neutral
2
4
Mounting M4.0 Thread
Triple
55.88 [2.20]
►All
63.5 [2.50]
dimensions in mm (inches)
►Tolerance:
►Pin
±0.5 (±0.02)
diameter ⇔ 1.0 ±0.1 (0.04±0.004)
Physical Outline
Case Size
Case Material
Pin Material
Weight
:
:
:
:
88.9x63.5x21.7mm (3.50x2.50x0.85 inches)
Plastic resin + Fiberglass (flammability to UL 94V-0 rated)
Copper Alloy with Gold Plate Over Nickel Subplate
177g
Mechancial Drawing Chassis Mounting (Option code, suffix C)
Mechanical Dimensions
Connections
4 x 3.5
Indication LED
Top view
2
1
63.8 [2.51]
7
6
5
4
3
50.0 [1.97]
Terminal
Dual
(0512)
AC(N) – AC Neutral
2
AC(L) – AC Line
+Vout
4
+Vout
NC
5
-Vout
+Vout2
+Vout2
+Vout1
+Vout1
+Vout1
-Vout2
Com.
2/3
Com. 2/3
-Vout1
-Vout1
-Vout1
NC
-Vout3
+Vout3
Common
100.0 [3.94]
6
NC
7
-Vout
10.0 [0.39]
NC: No Connection
5.0 [0.20]
16.8 [0.66]
25.6 [1.01]
92.0 [3.62]
NC
Triple
(050312, 030512)
+Vout2
POWER"GOOD"INDICATOR
112.0 [4.41]
Triple
1
3
DCON
Dual
(±12,
±15)
Single
►All
dimensions in mm (inches)
►Tolerance:
X.X±0.5 (X.XX±0.02)
X.XX±0.25 ( X.XXX±0.01)
►Pin
DS_AA30S_06172014
pitch tolerance: ±0.25 (0.01)
E-mail: DCDC@delta.com.tw
http://www.deltaww.com/dcdc
P4
Physical Outline
Case Size
:
112.0x63.8x25.6mm (4.41x2.51x1.01 inches)
Case Material
:
Plastic resin + Fiberglass (flammability to UL 94V-0 rated)
Weight
:
191g
Mechancial Drawing Chassis Mounting with DIN Rail Kit (Option code, suffix D)
Mechanical Dimensions
Indication LED
Top view
2
1
63.8 [2.51]
7
6
5
4
3
50.0 [1.97]
4 x 3.5
DCON
POWER"GOOD"INDICATOR
100.0 [3.94]
112.0 [4.41]
25.6 [1.01]
11.0 [0.43]
3.0 [0.12]
5.0
[0.20]
10.0 [0.39]
16.8 [0.66]
92.0 [3.62]
Physical Outline
Case Size
:
112.0x63.8x25.6mm (4.41x2.51x1.01 inches)
Case Material
:
Plastic resin + Fiberglass (flammability to UL 94V-0 rated)
Weight
:
245g
DIN-Rail Mounting Kit
DS_AA30S_06172014
E-mail: DCDC@delta.com.tw
http://www.deltaww.com/dcdc
P5
Part Numbering System
A
A
30
T
05
03
12
Product typ
Family
series
Watt
Number of
Outputs
Output
Voltage I
Output
Voltage II
Output
Voltage III
Option Code
AC/DC Power
Module
Industrial
application
30 - 30W
S - Single
05 - 5V
00 - not
applicable
05 – 5V
A - PCB Mount
D - Dual
12 - 12V
12 - 12V
12 - 12V
T - Triple
15 - 15V
15 - 15V
15 - 15V
24 - 24V
48 - 48V
03 – 3.3V
03 – 3.3V
05 - 5V
A
C - Chassis
Mount
D - Din Rail
Mount
CONTACT: www.deltaww.com/dcdc
USA:
Telephone:
East Coast: 978-656-3993
West Coast: 510-668-5100
Fax: (978) 656 3964
Email: DCDC@delta-corp.com
Europe:
Phone: +31-20-655-0967
Fax: +31-20-655-0999
Email: DCDC@delta-es.com
Asia & the rest of world:
Telephone: +886 3 4526107
ext 6220~6224
Fax: +886 3 4513485
Email: DCDC@delta.com.tw
WARRANTY
Delta offers a three(3) years limited warranty. Complete warranty information is listed on our web site or is available upon request
from Delta.
Information furnished by Delta is believed to be accurate and reliable. However, no responsibility is assumed by Delta for its use, nor
for any infringements of patents or other rights of third parties, which may result from its use. No license is granted by implication or
otherwise under any patent or patent rights of Delta. Delta reserves the right to revise these specifications at any time, without notice
DS_AA30S_06172014
E-mail: DCDC@delta.com.tw
http://www.deltaww.com/dcdc
P6