SPECIFICATION FOR APPROVAL
Customer : Digikey
Description : DC FAN
Customer Part No.
Delta Model No. : AFB0624EHDC9
Sample Issue No. :
Sample Issue Date : DEC.12 2017
REV. :
REV. :
1
00
PLEASE SEND ONE COPY OF THIS SPECIFICAITON BACK AFTER
YOU SIGNED APPROVAL FOR PRODUCTION PRE-ARRANGMENT.
APPROVED BY:
DATE
:
DELTA ELECTRONICS, INC.
TAOYUAN PLANT
252, SHANG YING ROAD, KUEI SAN INDUSTRIAL ZONE
TAOYUAN SHIEN, TAIWAN, R.O.C.
TEL:886-(0)3-3591968
FAX:886-(0)3-3591991
*** SAMPLE HISTORY***
CUSTOMER:
CUSTOMER P/N:
DELTA MODEL:
REV.
Digikey
AFB0624EHDC9
DESCRIPTION
00 ISSUE SPEC
DRAWN
CHECKED
ME
EE
李宜霖
黃嵩哲
李宜霖
11/17'17 11/17'17 11/17'17
CE
---
APPROVED
ISSUE
DATE
吳俊男
12/12'17
11/17'17
Delta Electronics, Inc.
No.252, Shanying Rd., Guishan Dist.,
Taoyuan City 333, Taiwan (R.O.C.)
TEL : 886-(0)3-3591968
FAX : 886-(0)3-3591991
STATEMENT OF DEVIATION
■ NONE
□ DESCRIPTION:
Delta Electronics, Inc.
No.252, Shanying Rd., Guishan Dist.,
Taoyuan City 333, Taiwan (R.O.C.)
TEL : 886-(0)3-3591968
FAX : 886-(0)3-3591991
Specification For Approval
Customer :
Digikey
Description : DC FAN
Customer P/N :
rev. :
Delta model no. : AFB0624EHDC9
Delta Safety Model No.: AFB0624EH
Sample revision. :
00
Sample issue date : DEC.12 2017
Issue no.:
Quantity :
1. SCOPE:
THIS SPECIFICATION DEFINES THE ELECTRICAL AND MECHANICAL
CHARACTERISTICS OF THE DC BRUSHLESS AXIAL FLOW FAN.
2. CHARACTERS:
ITEM
RATED VOLTAGE
OPERATION VOLTAGE
INPUT CURRENT(AVG.)
DESCRIPTION
24V
14.0 - 27.6 VDC
0.24(MAX. 0.32) A
SAFETY CURRENT ON LABEL : 0.36A
INPUT POWER(AVG.)
SPEED (AT RATED VOLTAGE)
5.76 (MAX.7.68) W
6800±10% R.P.M.
MAX. AIR FLOW
(AT ZERO STATIC PRESSURE)
1.086 (MIN. 0.977) M3 /MIN.
38.35(MIN. 34.50) CFM
MAX. AIR PRESSURE
(AT ZERO AIRFLOW)
13.81(MIN. 11.18) mmH2O
0.544 (MIN. 0.441) inchH2O
ACOUSTICAL NOISE (AVG.)
INGRESS PROTECTION
INSULATION TYPE
INSULATION STRENGTH
DIELECTRIC STRENGTH
46.5 (MAX. 50.5) dB-A
IP55 (IEC60529)
UL: CLASS A
10 MEG OHM MIN. AT 500 VDC
(BETWEEN FRAME AND (+) TERMINAL)
5 mA MAX. AT 500 VAC 50/60 Hz ONE MINUTE,
(BETWEEN FRAME AND (+) TERMINAL)
(continued)
PAGE 1
PART NO:
DELTA MODEL:
AFB0624EHDC9
LIFE EXPECTANCE (L10)
(AT LABEL VOLTAGE)
70,000 HOURS CONTINUOUS OPERATION AT 40 °
C WITH 15 ~ 65 %RH.
ROTATION
CLOCKWISE VIEW FROM NAME PLAT SIDE
LOCKED PROTECTION
THE CURRENT WILL SHUT DOWN, WHEN ROTOR
LOCKED AND FIXED.
NOTES:
1. ALL READINGS ARE MEASURED AFTER STABLY WARMING UP
THROUGH 10 MINUTES.
2. STANDARD AIR PROPERTY IS AIR AT (Td) 25°C TEMPERATURE, (RH) 65%
RELATIVE HUMIDITY , AND (Pb) 760 mmHg BAROMETRIC PRESSURE.
3. THE VALUES WRITTEN IN PARENS , ( ), ARE LIMITED SPEC.
4. ACOUSTICAL NOISE MEASURING CONDITION:
NOISE IS MEASURED AT RATED VOLTAGE IN FREE AIR IN ANECHOIC
CHAMBER WITH B & K SOUND LEVEL METER WITH MICROPHONE AT A
DISTANCE OF ONE METER FROM THE FAN INTAKE.
PAGE 2
PART NO:
DELTA MODEL:
AFB0624EHDC9
3.MECHANICAL:
3-1. DIMENSIONS-------------------------------------------- SEE DIMENSIONS DRAWING
3-2. FRAME------------------------------------------------------------------- PLASTIC UL: 94V-0
3-3. IMPELLER--------------------------------------------------------------- PLASTIC UL: 94V-0
3-4. BEARING SYSTEM---------------------------------------------- TWO BALL BEARINGS
3-5. WEIGHT---------------------------------------------------------------------- 80 GRAMS(REF.)
4. ENVIRONMENTAL:
4-1. OPERATING TEMPERATURE------------------------------ -10 TO +70 DEGREE C
4-2. STORAGE TEMPERATURE--------------------------------- -40 TO +75 DEGREE C
4-3. OPERATING HUMIDITY----------------------------------------------------- 5 TO 90 % RH
4-4. STORAGE HUMIDITY-------------------------------------------------------- 5 TO 95 % RH
5. PROTECTION:
5-1. LOCKED ROTOR PROTECTION
IMPEDANCE OF MOTOR WINDING PROTECTS MOTOR FROM FIRE IN
96 HOURS OF LOCKED ROTOR CONDITION AT THE RATED VOLTAGE.
5-2. POLARITY PROTECTION
BE CAPABLE OF WITHSTANDING IF REVERSE CONNECTION FOR
POSITIVEAND NEGATIVE LEADS.
6. RE OZONE DEPLETING SUBSTANCES:
6-1. NO CONTAINING PBBs, PBBOs, CFCs, PBBEs, PBDPEs AND HCFCs.
7. PRODUCTION LOCATION
7-1. PRODUCTS WILL BE PRODUCED IN CHINA OR THAILAND.
PAGE 3
PART NO:
DELTA MODEL:
AFB0624EHDC9
8. P & Q CURVE:
*TEST CONDITION: INPUT VOLTAGE-----OPERATION VOLTAGE
TEMPERATURE-----ROOM TEMPERATURE
HUMIDITY-----65%RH
PAGE 4
PART NO:
DELTA MODEL:
AFB0624EHDC9
9. DIMENSION DRAWING:
LABEL:
Digikey
NOTES:
1.THIS PRODUCT IS ROHS COMPLIANT.
2. CABLE WIRE: UL1007 AWG#24.
RED WIRE-----(+)
BLACK WIRE-----(-)
BLUE WIRE------(R00)
PAGE 5
PART NO:
DELTA MODEL:
AFB0624EHDC9
10. ROTATION DEFECT (RD) SIGNAL:
10-1. OUTPUT CIRCUIT - OPEN COLLECTOR MODE:
VRD
Ic
MOTOR
DRIVER
R
VCE
RD SIGNAL
CAUTION:
THE LEAD WIRE OF RD SIGNAL CAN NOT TOUCH
THE LEAD WIRE OF POSITIVE OR NEGATIVE.
10-2. SPECIFICATION:
VRD= 5.0 TYP.(Vcc MAX.) Ic = 5mA MAX.
R ≧ VRD /Ic
VCE= 0.5V MAX.
10-3. ROTATION DEFECT WAVEFORM:
VRD
0.5V
MAX.
RUNNING
LOCKED
PAGE 6
RUNNING
Application Notice
1. Delta will not guarantee the performance of the products if the application condition
falls outside the parameters set forth in the specification.
2. A written request should be submitted to Delta prior to approval if deviation from
this specification is required.
3. Please exercise caution when handling fans. Damage may be caused when pressure is
applied to the impeller, if the fans are handled by the lead wires, or if the fan was
hard-dropped to the production floor.
4. Except as pertains to some special designs, there is no guarantee that the products will
be free from any such safety problems or failures as caused by the introduction of
powder, droplets of water or encroachment of insect into the hub.
5. The above-mentioned conditions are representative of some unique examples and viewed
as the first point of reference prior to all other information.
6. It is very important to establish the correct polarity before connecting the fan to the
power source. Positive (+) and Negative (-). Damage may be caused to the fans if
connection is with reverse polarity, if there is no foolproof method to protect against
such error specifically mentioned in this spec.
7. Delta fans without special protection are not suitable where any corrosive fluids are
introduced to their environment.
8. Please ensure all fans are stored according to the storage temperature limits specified.
Do not store fans in a high humidity environment. We highly recommend performance
testing is conducted before shipping, if the fans have been stored over 6 months.
9. Not all fans are provided with the Lock Rotor Protection feature. If you impair the
rotation of the impeller for the fans that do not have this function, the performance
of those fans will lead to failure.
10. Please be cautious when mounting the fan. Incorrect mounting of fans may cause
excess resonance, vibration and subsequent noise.
11. It is important to consider safety when testing the fans. A suitable fan guard should be
fitted to the fan to guard against any potential for personal injury.
12. Except where specifically stated, all tests are carried out at room (ambient) temperature
and relative humidity conditions of 25oC, 65% RH. The test value is only for fan
performance itself.
13. Be certain to connect an “ 4.7µF or greater” capacitor to the fan externally when
the application calls for using multiple fans in parallel, to avoid any unstable power.
很抱歉,暂时无法提供与“AFB0624EHDC9”相匹配的价格&库存,您可以联系我们找货