AFB1248VHE-TP18

AFB1248VHE-TP18

  • 厂商:

    DELTA(台达)

  • 封装:

    插件

  • 描述:

    FAN AXIAL 120X38MM 48VDC WIRE

  • 详情介绍
  • 数据手册
  • 价格&库存
AFB1248VHE-TP18 数据手册
SPECIFICATION FOR APPROVAL =============================================== Customer Description DC FAN Part No. Rev. Delta Model No. AFB1248VHE-TP18 Rev. 00 Sample Issue No. Sample Issue Date. Apr 30, 09 PLEASE SEND ONE COPY OF THIS SPECIFICATION BACK AFTER YOU SIGNED APPROVAL FOR PRODUCTION PRE-ARRANGEMENT. APPROVED BY : _____________________________ DATE : _____________________________ DELTA ELECTRONICS (THAILAND) PUBLIC COMPANY LIMITED. 111 MOO 9 WELLGROW INDUSTRIAL ESTATE BANGNA-TRAD ROAD, TAMBON BANGWUA, AMPHUR BANGPAKONG, CHACHOENGSAO 24180 THAILAND TEL. +66-(0)-38522455, FAX. +66-(0)-38522477 DEL-0776A4 Descriptions: 1. Delta will not guarantee the performance of the products if the application condition falls outside the parameters set forth in the specification. 2. A written request should be submitted to Delta prior to approval if deviation from this specification is required. 3. Please exercise caution when handling fans. Damage may be caused when pressure is applied to the impeller, if the fans are handled by the lead wires, or if the fans are hard-dropped to the production floor. 4. Except as pertains to some special designs, there is no guarantee that the products will be free from any such safety problems or failures as caused by the introduction of powder, droplets of water or encroachment of insect into the hub. 5. The above-mentioned conditions are representative of some unique examples and viewed as the first point of reference prior to all other information. 6. It is very important to establish the correct polarity before connecting the fan to the power source. Positive (+) and Negative (-). Damage may be caused to the fans if connection is with reverse polarity, as there is no foolproof method to protect against such error. 7. Delta fans are not suitable where any corrosive fluids are introduced to their environment. 8. Please ensure all fans are stored according to the storage temperature limits specified. Do not store fans in a high humidity environment. We highly recommend performance testing is conducted before shipping, if the fans have been stored over 6 months. 9. Not all fans are provided with the Lock Rotor Protection feature. If you impair the rotation of the impeller for the fans that do not have this function, the performance of those fans will lead to failure. 10. Please be cautious when mounting the fan. Incorrect mounting of fans may cause excess resonance, vibration and subsequent noise. 11. It is important to consider safety when testing the fans. A suitable fan guard should be fitted to the fan to guard against any potential for personal injury. 12. Except where specifically stated, all tests are carried out at relative (ambient) temperature and humidity conditions of 25oC, 65%. The test value is only for fan performance itself. 13. Be certain to connect an “over 4.7µF” capacitor to the fan externally when the application calls for using multiple fans in parallel, to avoid any unstable power.
AFB1248VHE-TP18
物料型号:AFB1248VHE-TP18 器件简介:直流无刷轴流风扇 引脚分配:红线(+),黑线(-),蓝线(-F00),黄线(PWM) 参数特性: - 额定电压:48 VDC - 工作电压:34.0 - 56.0 VDC - 输入电流:最大0.38 A - 输入功率:最大18.24 W - 速度:4100±10% R.P.M. - 最大气流:5.394 M³/MIN - 最大风压:17.635 mmH2O - 噪音:平均55.5 dB-A,最大59.5 dB-A - 绝缘类型:UL CLASS A 功能详解:风扇具有锁定转子保护和极性保护,可在40至70摄氏度的温度范围内工作,并且能够在5至90%RH的湿度下运行。

应用信息:适用于需要直流风扇散热的场合,如计算机、服务器、通信设备等。

封装信息:开放型外部罩,尺寸和重量详细信息参见尺寸图。

产品符合RoHS标准。
AFB1248VHE-TP18 价格&库存

很抱歉,暂时无法提供与“AFB1248VHE-TP18”相匹配的价格&库存,您可以联系我们找货

免费人工找货