Automation for a Changing World Delta Hot Swappable Mid-range PLC AH Series w w w. d e l t a w w. c o m AH - Automation System for High-level Applications The new generation AH Series PLC provides automation solutions for high-level applications. The combination of modularized hardware structure, advanced functions, and the highly integrated software provides a system solution for process control applications. In addition to various function blocks, excellent performance, and an abundant selection of extension modules, the AH Series PLC also provides exceptional system expandability and full redundant solution, greatly reducing the system cost for a broad range of applications. »Highly » integrated software ISPSoft: graphical interface with 5 programming languages »Enhanced » flexibility: Max. 100m or 2 km (optical fiber) between 2 local extension racks »Redundant » and hot-swapping functions keep the system running for improved maintainability »Reliable » operations of the supported modules in severe conditions * Operating condition: -20 ~ 60°C / 5 ~ 95% (Non-condensing) * Storage condition: -40 ~ 70°C / 5 ~ 95% (Non-condensing) • Utilizes 32-bit processor and real-time operation system (RTOS) • Max. I/O points: DIO: Max. 4,352 points AIO: Max. 544 channels RIO: >100,000 points • Program capacity: Max. 1 M steps (4 MB) Data register (D+L): 512 k words • Excellent program execution speed: LD instruction execution speed: 0.02 µs • CPU built-in with fully isolated RS-232 / 422 / 485, Mini-USB, Ethernet and SDHC card slot • Abundant selection of DIO modules,AIO modules, temperature measurement modules, network modules, pulse-train modules and DMCNET / EtherCAT motion control modules 1 Contents Page 2 AH Series PLC – Automation System with Fully Integrated Hardware and Software Interfaces 3 Redundant CPU 5 Standard / Compact Motion Control System 7 Applications 9 AH System Structure 11 ISPSoft V3.0 Highly Accessible Programming Software 13 PMSoft V2.0 16 Specification Tree 17 CPU Selection Table 18 Model Name 19 Dimensions 21 Accessory Selection for High-density Modules 30 Ordering Information 36 AH Series PLC – Automation System with Fully Integrated Hardware and Software Interfaces Max. 100 m or 2 km (optical fiber) between 2 Racks Automation System elns v e o -l ti s h ca n o i ig li t a H p c p li p A p I/O Hot Swapping Advanced Hardware Structure S d n ta rd A a Highly Integrated Software Highly Integrated Software – Excellent Accessibility AH PLCs adopt the highly accessible programming software ISPSoft, integrating the main functions that include control process programming, hardware configuration, network configuration, and providing a graphical interface for these functions. In addition, users of ISPSoft can choose their most efficient programming tools from the 5 supported languages: Ladder Diagram (LD), Function Block Diagram (FBD), Sequential Function Chart (SFC), Instruction List (IL) and Structured Text (ST). LD ST FBD IL SFC 3 Enhanced Flexibility – Extends the System Freely The length of extension cables between each AH local extension rack can reach a maximum of 100 m or 2 km (optical fiber), greatly enhancing wiring flexibility. In addition, the AH provides modularized backplanes and modules applicable for not only CPU racks but also for remote I/O racks. This feature improves the flexibility of system planning and reduces the additional cost that might be generated by preparing two different types of spare backplanes and modules. System Extension Structure Remote I/O bus Extension bus (Optical Fiber) Extension bus Supports ▪▪DeviceNet ▪▪PROFIBUS ▪▪EtherNet/IP Fiber Module Local Extension Bus: ▪▪Max. Extension = 7 Racks ▪▪Max. Distance = 100 m or 2 km (Optical fiber) (Between 2 Racks) = 700 m or 14 km (Optical fiber) (Total) Local Extension Bus: ▪▪Max. Extension = 7 Racks ▪▪Max. Distance = 100 m or 2 km (Optical fiber) (Between 2 Racks) = 700 m or 14 km (Optical fiber) (Total) Fiber Module Improved Maintainability – Keeps the System Running The hot-swap function provided for AIO and DIO modules increases maintainability when I/O modules fail. Users can replace modules without stopping the operation of the CPU module, preventing a possible loss due to a pause in the system's operation. 4 Redundant CPU The redundant CPU of the AH Series adopts a reliable redundancy structure, and integrates synchronous modules, Ethernet ports and serial communication interfaces for a more competitive control solution. AHCPU560-EN2 SD card ▪▪Micro SD (max 32 GB) Serial port ▪▪Removable terminal block ▪▪RS-232 / RS-485 Ethernet port Sync. optical port ▪▪RJ45 x 2 ▪▪Data sync. ▪▪EtherNet/IP (DLR) Redundant Backplane The redundant backplane of the AH Series provides redundant power supply and communciation interfaces for a complete control solution. Redundant main backplane: AHBP04MR1-5A (4-slot), AHBP06MR1-5A (6-slot), AHBP08MR1-5A (8-slot) Redundant Power Redundant expansion backplane: AHBP06ER1-5A (6-slot) Redundant Ext. Ports Redundant Power 5 Redundant System Full Redundancy Structure Redundant CPU Redundant main backplane Redundant power Redundant ext. ports Ring topology Modules Main backplane Expansion backplane RTU rack ▪ Ethernet module - AH10EN-5A (V3) ▪ DIO ▪ DIO ▪ Serial module - AH10SCM-5A (V3) ▪ AIO (includes temperature modules) ▪ AIO (include temperature modules) ▪ Serial modules - AH10SCM-5A, AH15SCM-5A Tasks Cyclic Timer interrupt CPU built-in sync. module CPU switch-over time: 20 ms RTU nodes to support expansion backplanes Standard backplanes available (under some conditions) 4 Modbus TCP 4 Master PLC Backup PLC 1 3 Ext. cable for backplane (DLR) 2 3 Redundant expansion backplane RTU Redundant expansion backplane RTU 1 Sync. optical fiber 3 2 Ext. cable for backplane 4 ring topology ( DLR ) Star topology 6 , Modbus TCP Standard Motion Control System ►► Provides EtherCAT, DMCNET and pulse train solutions for customers. ►► Motion modules can independently take care of both the logic and motion control. Users can write and download the programs to the motion modules. ►► All motion modules support the standard motion control system. ►► All motion modules can be installed on the local backplanes. ►► Motion control functions: »»Performance: -Pulse train module: Max. 1 MHz output -DMCNET module: Min. synchronization time at 12 axes is 1 ms -EtherCAT module: Min. synchronization time at 8 / 16 / 32 axes is 0.5 / 1 / 2  ms »»Supports UD / PD / AB / 4AB input modes »»Supports MPD inputs / E-Cam / G-code / 2 ~ 6 axes linear interpolation / 2 axes arc interpolation / 3 axes helical interpolation Note: The EtherCAT modules (AHxxEMC-5A) do not support G-code. (Modbus) PS AH-CPU Main backplane RS-232 / 422 / 485 MORE Ethernet (Modbus TCP) AH-20EMC  / AH-20MC  / AH-10PM Pulse train Total: 6 DMCNET Total: 12 EtherCAT Total: 32 Expansion backplane MORE Pulse train DMCNET EtherCAT 7 Total: 6 Total: 12 Total: 32 Compact Motion Control System ►► Provides EtherCAT, DMCNET and pulse train solutions for customers. ►► AHxxEMC-5A motion controller can be installed on the CPU slot of the specific motion backplane and works as a CPU module. ►► Compact motion control system does not support the expansion backplane. ►► Motion modules can be installed on the I/O slot of the motion backplane. ►► Motion control functions: »»Performance: -Pulse train module: Max. 1 MHz output -DMCNET module: Min. synchronization time at 12 axes is 1 ms -EtherCAT module: Min. synchronization time at 8 / 16 / 32 axes is 0.5 / 1 / 2  ms »»Supports UD / PD / AB / 4AB input modes »»Supports MPD inputs / E-Cam / G-code / 2 ~ 6 axes linear interpolation / 2 axes arc interpolation / 3 axes helical interpolation Note: The EtherCAT modules (AHxxEMC-5A) do not support G-code. PS Motion backplane (AHBP05M2-5A) (Modbus) RS-485 MORE Ethernet (Modbus TCP) AH-20EMC / AH-20MC /  AH-10PM Pulse train Total: 6 DMCNET Total: 12 EtherCAT Total: 32 8 Applications Large Scale Industrial Machines The features of the AH can easily fulfill the system requirements of large scale industrial machines. By utilizing its unique local extension capability with versatile combinations of I/O modules, the AH can simplify the complex remote I/O system structure in large scale industrial machines with a local I/O system consisting of a single CPU rack and local extension racks, maintaining a high execution speed and lowering the wiring cost. Building Material Processor AH ASDA-A2 Warp Knitting Machine AH The AH also supports excellent motion control functions including 3-axis linear interpolation, 2-axis arc interpolation, and 3-axis helical interpolation. In addition, the AH is capable of controlling up to 12 axes or 4 groups of 3-axis interpolation synchronously through Delta's high speed motion control network DMCNET. AH Z Axis Y Axis AH performing 4 groups of 3-axis interpolation through DMCNET X Axis 9 System Applications The AH is a modular system controller designed for almost all kinds of high-level automation tasks. The abundant selection of I/O modules and the flexible system structure provide the best solutions for all types of system integration requirements. Through the remote I/O expandability, you can build up the AH main station as a central control system and allocate the remote I/O systems on different floors for HVAC applications, or in different processing stations for the paper-making industry. The AH can not only fulfill the application requirements of industrial machines or devices, but it can also provide total solutions for automation systems. HVAC Papermaking Industries DeviceNet Remote I/O Mechanical Pulp Molding Technology Forestry Waste Paper Recycled Pulp Processing Remote I/O Mixed Cylinder DeviceNet Sifting and Sorting Finishing Main Station Papermaking Machines AH 10 AH System Structure – Facility Monitoring and Control System The system configuration of the AH is well demonstrated by the Facility Monitoring and Control System (FMCS). The AH in the control layer connects multiple facility systems and product processing systems and performs data exchange without programming through Delta's convenient PLC Link and Ether Link. PLC Link can be applied for data exchange between masters and slaves, and Ether Link can be applied for data exchange between AH master stations. The smart communication feature can save you time spent in programming. AH Station 11 AH Station AH Station In addition to AH PLCs, Delta's industrial automation solution includes human machine interfaces (HMI), DVS series industrial Ethernet switches, DVP series PLCs, AC motor drives, AC servo drives and temperature controllers. You can find the best solution for your industry from our product lines across the device layer, control layer and information layer. AH Station AH Station 12 ISPSoft V3.0 Highly Accessible Programming Software Fully Integrated Interface Advanced Programming Interface + Visualized Hardware Configuration + Simplified Network Configuration + Data Tracer & Logger + Motion programming Communication Management Simplified Network Configuration Advanced Programming Interface Visualized Hardware Configuration Advanced Programming Interface Project Management Window Toolbar Programming Area • New Functions: Network configuration, hardware configuration and PLC card. • Supports 5 programming languages (LD / FBD / SFC / IL / ST) • Function Blocks: Symbols can be introduced in call-by-value or call-by-reference types. Function blocks can be called in function block for up to 32 levels. • Monitor Table: It can be stored and managed separately. Multiple monitor tables can be stored in a single project. • User Library: Users can design frequently used instructions for specific applications in different industries. • Task: Supports cyclic, I/ O interrupt, timer interrupt, external interrupt, and more. Software will provide usable tasks for different CPUs. Message Window 13 Library Management Visualized Hardware Configuration Toolbar • System hardware configuration can be monitored in On-Line mode Module Selection • Hardware configuration can be displayed by Scan function Hardware Configuration Area • Operations of Cut / Copy / Paste / Delete are available for modules and racks Module Description • Parameters of each module can be directly configured Rack Information • I/O device range can be specified by the user Simplified Network Configuration 192 . 168 . 1 . 11 Station 11 192 . 168 . 1 . 12 Station 12 192 . 168 . 1 . 13 Station 13 FMCS Ethernet RS-485 Station 21 Station 22 Station 23 Toolbar Network Device Selection Network Configuration Area Ether Link • Master device settings • Ether Link editing function • PLC Link editing function PLC Link Network Information 14 Data Tracer & Logger Data Tracer Provides high speed data log ability and the interval could be 1 CPU scan. Users can easily analyze the program logic with this function. Data Logger Provides big data log ability and adjustable intervals. Users can log critical system data and then analyze the system operation status. Tool Bar Axis y: Value Trend Chart Area Axis x: Samples No. Configuration Area Integrated Motion Programming ISPSoft V3 integrates the logic and motion program editors into one software G-code Simulation Axis Property 15 E-CAM Edit PMSoft V2.0 This programming software is for G-code editing, motion trajectory simulation, positioning route instruction and electronic cam establishment. Variable Declaration Separate from the program. The corresponding physical I/O point of the variable is defined only after the program is compiled. Users do not need to modify the program. Function Block A complicated project can be divided into many function blocks. A function block can be used repeatedly. The import / export function makes the programming more convenient. Function Block for Motion Control Provides function block features specifically for motion control, making programming more convenient Convenient Monitor Table Management Users can save and manage monitor tables independently according to their needs. Electronic Cam Electronic cam editing CFC Editor Supports CFC programming language SCMSoft V1.0 Communication Editing Software Provides SCM module with automatic data exchange setup function Toolbar ▪▪Upload /  Download setup files Project Management Interface ▪▪Supports wizards ▪▪Supports user defined protocol (UD Link) ▪▪Supports Modbus protocol ▪▪Supports data monitoring for communication ports Editing Area ▪▪Data exchange setup ▪▪Status display 16 Specification Tree RS-232 (Excludes 560) RS-232 RS-422 RS-485 COM1 COM1 Feature Ethernet Feature RS-422 COM2 Model RS-232 RS-485 Model IO-768 / FB-128 P-32K / D-16K No Extension Rack 500 500 IO-768 / FB-128 P-32K / D-16K No Extension Rack IO-768/FB-512 P-48K/D-24K No Extension Rack 501 501 IO-768/FB-512 P-48K/D-24K No Extension Rack IO-1280 / FB-256 P-64K / D-32K 1 Extension Rack 510 510 IO-1280 / FB-1024 P-96K / D-48K 1 Extension Rack IO-1280 / FB-256 P-64K / D-32K 1 Extension Rack 511 511 IO-2304 / FB-512 P-128K / D-64K 3 Extension Racks IO-1280 / FB-1024 P-96K / D-48K 1 Extension Rack 520 520 IO-2304 / FB-2048 P-192K / D-96K 3 Extension Racks IO-2304 / FB-512 P-128K / D-64K 3 Extension Racks 521 IO-4352 / FB-1024 P-256K / D-64K 7 Extension Racks 521 530 IO-2304 / FB-2048 P-192K / D-96K 3 Extension Racks IO-4352 / FB-4096 P-384K / D-128K 7 Extension Racks 530 531 IO-4352 / FB-1024 P-256K / D-64K 7 Extension Racks IO-4352 / FB-4096 P-1M / D-256K 7 Extension Racks Supports redundancy 531 IO-4352 / FB-4096 P-384K / D-128K 7 Extension Racks 560 EN RS2 COM USB Trans. Trans. Ethernet Backup / Restore Error log / Recipt SD SD 17 COM USB Backup / Restore Error log / Recipt CPU Selection Table CPU Model Item Specifications Check AH500 AH510 AH520 AH530 AH501 AH511 AH521 AH531 RS2 EN RS2 EN RS2 EN RS2 EN RS2 EN RS2 EN RS2 EN DNP RS2 EN • Local I/O points < 768 • • < 1280 • < 2304 • Program capacity • • • • < 96k steps • < 128 k steps • < 192 k steps • < 256k steps • < 384 k steps • Built-in communication Expansion capacity < 1M steps • • < 1 expansion rack • < 3 expansion racks • < 7 expansion racks • 1 COM port 2 COM ports • Ethernet Mini-USB Modbus Protocol supported • None • • Modbus TCP • • • • • • • • • • • • • • • • • • • • • • • • • EtherNet/IP • • • • • • • • • • • SD card Redundancy • • • • V 2.0 (SDHC) • • • • • • • • DNP3 V 1.0 EN2 • < 48k steps < 64k steps • • < 4352 < 32 k steps • AH560 • • • • • • • • • • • • • • • • • • • V 2.0 (Micro SDHC) • CPU • 18 Model Name AH CPU AHCPU500-RS2 AH CPU 5 0 0 Series Classification Model Function Version CPU - RS2 Type 0: No expansion rack 1: 1 expansion rack 2: 3 expansion racks 3: 7 expansion racks 6: Redundant CPU RS2: 2 COM ports EN: 1 COM & 1 Ethernet ports EN2: 1 COM & 2 Ethernet ports DNP: 1 COM & 1 Ethernet ports, supports DNP3 AH Power Supply Module AH RTU Module AHPS05-5A AHRTU-DNET-5A AH Series PS 05 Classification Power supply - Function 5A AH Type Series 05: AC input (100 ~ 240 V) 15: DC input (24 V) RTU - DNET Classification Remote terminal unit - Function 5A Type DNET: DeviceNet PFBS: PROFIBUS ETHN: EtherNet/IP AH Digital I/O Module AH16 AM10N-5A AH 16 Series I/O points AM 1 0 N Classification Function Function Function 16: 16 points AM: Digital input 0: No input 0: No output 32: 32 points AN: Digital output 1: DC input (24 V) 1: 0.5A transistor / TRIAC output or 2 A relay output 64: 64 points AP: Digital input / output 3: AC input (120 ~ 240 V) 2: 0.1 A transistor output AR: Digital input with interrupt AH Analog I/O Module AH04 AD-5A AH Series 04 I/O Channels 04: 4-channel 06: 6-channel 08: 8-channel AD - 5A Classification AD: Analog input DA: Analog output XA: Analog input / output Type 5A: Voltage / Current 5B: Voltage 5C: Current 19 N: No output R: Relay output T: NPN output P: PNP output S: TRIAC output - 5A Type 5A: Removable terminal 5B: DB37 connector 5C: MIL AH Backplane AHBP04M1-5A AH BP 04 M1 Series Classification Function Function Backplane 00: No slot 03: 3-slot 04: 4-slot 05: 5-slot 06: 6-slot 07: 7-slot 08: 8-slot 12: 12-slot - 5A Type M1: Main backplane M2: Main backplane for motion E1: Expansion backplane MR1: Redundant main backplane ER1: Redundant expansion backplane AH Network Module AH10EN-5A AH 10 EN Series Function Classification 10: Basic 15: Advanced EN: Ethernet SCM: Serial communication DNET: DeviceNet - 5A Type PFBM: PROFIBUS master PFBS: PROFIBUS slave COPM: CANopen AH Motion Module AH02HC-5A AH 02 Series HC Function 02: 2-channel 04: 4-channel 05: Simple type (PM) 10: Standard type (PM) 15: Advanced type (PM) - Classification 20: DMCNET 08E: EtherCAT (8-axis) 10E: EtherCAT (16-axis) 20E: EtherCAT (32-axis) Type HC: High speed counter PM: Motion controller (Pulse train) MC: Motion controller (Network) AH Temperature Module AH04PT-5A AH 04 PT Series I/O channels Classification 04: 4-channel 08: 8-channel - PT: Platinum resistance thermometer TC: Thermocouple PTG: Platinum resistance thermometer (channel isolation) 20 5A 5A Type Dimensions Dimensions are in mm CPU Modules Model Name H W D AHCPU500-RS2 110 40 103 AHCPU501-RS2 110 40 103 AHCPU510-RS2 110 40 103 AHCPU511-RS2 110 40 103 AHCPU520-RS2 110 40 103 AHCPU521-RS2 110 40 103 AHCPU530-RS2 110 40 103 AHCPU531-RS2 110 40 103 W Backplanes D Model Name H W W1 AHBP04M1-5A 110 298 272.5 AHBP06M1-5A 110 369 343.5 AHBP08M1-5A 110 440 414.5 AHBP12M1-5A 110 582 556.5 AHBP03M2-5A 110 257 232.4 AHBP05M2-5A 110 328 303 AHBP07M2-5A 110 399 374 AHBP06E1-5A 110 328 303 AHBP08E1-5A 110 399 374 H H W1 W Model Name H W D AHCPU500-EN 110 40 103 AHCPU501-EN 110 40 103 AHCPU510-EN 110 40 103 AHCPU511-EN 110 40 103 AHCPU520-EN 110 40 103 AHCPU521-EN 110 40 103 AHCPU521-DNP 110 40 103 AHCPU530-EN 110 40 103 AHCPU531-EN 110 40 103 W Model Name H W W1 AHBP04MR1-5A 110 348 323 AHBP06MR1-5A 110 419 394 AHBP08MR1-5A 110 490 465 AHBP06ER1-5A 110 398 373 AHBP08ER1-5A 110 469 444 H D W1 W H Model Name H W D AHCPU560-EN2 110 40 103 CLR RUN ERROR BUS FAULT 110 RST SYSTEM COM MST. SYNC MASTER SYNC USB RUN 110 STOP DD+ DD+ SG SG RX RX TX TX Ethernet Ethernet SYNC SYNC 16.0 H W D AHBP00M2-5A 110 65 92.1 65 103 40 CPU560-EN2 RUN ERR. B FLT SYS. COM Model Name 6 21 92.1 Power Supply Modules Model Name H 32-point Digital I/O Modules W D Model Name H W D AHPS05-5A 110 50 103 AH32 AM10N-5B 110 35 103 AHPS15-5A 110 50 103 AH32 AN02T-5B 110 35 103 AH32 AN02P-5B 110 35 103 D W W D H H 16-point Digital I/O Modules 32-point Digital I/O Modules Model Name H W D Model Name H W D AH16 AM10N-5A 110 35 103 AH32 AM10N-5C 110 35 103 AH16 AM30N-5A 110 35 103 AH32 AN02T-5C 110 35 103 AH16 AN01R-5A 110 35 103 AH32 AN02P-5C 110 35 103 AH16 AN01T-5A 110 35 103 AH16 AN01P-5A 110 35 103 AH16 AN01S-5A 110 35 103 AH16 AP11R-5A 110 35 103 AH16 AP11T-5A 110 35 103 AH16 AP11P-5A 110 35 103 AH16 AR10N-5A 110 35 103 W W D H D 64-point Digital I/O Modules H Model Name H W D AH64 AM10N-5C 110 35 103 AH64 AN02T-5C 110 35 103 AH64 AN02P-5C 110 35 103 W 32-point Digital I/O Modules Model Name H W D AH32 AM10N-5A 110 35 103 AH32 AN02T-5A 110 35 103 AH32 AN02P-5A 110 35 103 W H D H 22 D Dimensions Dimensions are in mm Analog I/O Modules Model Name Temperature Measurement Modules H W D Model Name H W D AH04AD-5A 110 35 103 AH04PT-5A 110 35 103 AH08AD-5B 110 35 103 AH04TC-5A 110 35 103 AH08AD-5C 110 35 103 AH08TC-5A 110 35 103 AH04DA-5A 110 35 103 AH08DA-5B 110 35 103 AH08DA-5C 110 35 103 AH06XA-5A 110 35 103 W W D H D H Analog I/O Modules Temperature Measurement Module Model Name H W D Model Name H W D AH08AD-5A 110 35 103 AH08PTG-5A 110 35 103 AH08DA-5A 110 35 103 D W 08PT W RUN D ERROR 08AD RUN ERROR O0+ I0+ O0- I0- O1+ I1+ O1- I1FG FG H I0+ I4+ V0+ V4+ H VI0- VI4- O2+ I2+ O2- I2O3+ I3+ O3- I3- O4+ I4+ O4- I4- I1+ I5+ V1+ V5+ O5+ I5+ VI1- VI5- O5- I5FG FG I2+ I6+ O6+ I6+ V2+ V6+ O6- I6- VI2- VI6- O7+ I7+ O7- I7- I3+ I7+ V3+ V7+ ZP UP VI3- VI7- RTD 2/3/4-WIRE SG SG 6 123.4 Network Module Model Name H W D AH10EN-5A 110 35 103 AH15EN-5A 110 35 103 W H 23 D Network Module Network Module Model Name H W D Model Name H W D AH10SCM-5A 110 35 103 AH15SCM-5A 110 35 103 W 35 D 103 15SCM RUN 110 ERROR H COM1 COM2 6 Network Module Network Module Model Name H W D Model Name H W D AH10PFBM-5A 110 35 103 AH10PFBS-5A 110 35 103 D W W D 10PFBM RUN SYS DP H CONF H Profibus Network Module Network Module Model Name H W D Model Name H W D AH10DNET-5A 110 35 103 AH10COPM-5A 110 35 103 W D W D 10COPM RUN ERROR 1 x16 Node Address 0 x16 H H DR 2 DR 1 DR 0 IN 0 CAN+ SHLD CANGND 24 Dimensions Dimensions are in mm RTU Module RTU Module Model Name H W D Model Name H W D AHRTU-DNET-5A 110 40 103 AHRTU-PFBS-5A 110 40 103 W W D RTU-PFBS D RTU-PFBS RUN RUN NET NET 1 x16 Node Address 0 x16 H H Motion Control Module RTU Module Model Name H AHRTU-ETHN-5A W 110 40 W D 103 Model Name H W D AH04HC-5A 110 35 103 W D MS MS NS NS IO IO D 1 x16 H IP Address 192.168.1.X 0 H x16 Link X1 Ack Link X2 Ack Motion Control Module Motion Control Module Model Name H W D AH02HC-5A 110 35 103 W Model Name H W D AH05PM-5A 110 35 103 D D W H H Motion Control Module Model Name Motion Control Modules H W D AH20MC-5A 110 35 103 AH10PM-5A 110 35 103 AH08EMC-5A 110 35 103 AH15PM-5A 110 35 103 AH10EMC-5A 110 35 103 AH20EMC-5A 110 35 103 W Model Name W D H H 25 H W D D External Terminal Modules Dummy Module Model Name H W D Model Name H W AHASP01-5A 110 35 103 UB-10-OR16A 87 113 UB-10-OR16B 87 113 W D ASP01 H External Terminal Modules External Terminal Modules Model Name H W Model Name H W UB-10-ID32A 87 113 UB-10-OR32A 87 215 UB-10-OT32A 87 113 UB-10-OR32B 87 215 External Terminal Modules External Terminal Modules Model Name H W UB-10-ID32B 87 113 UB-10-OT32B 87 113 26 Model Name H W UB-10-IO16C 87 125 UB-10-IO22C 87 125 UB-10-IO24C 87 157 UB-10-IO34C 87 157 Dimensions Dimensions are in m Cables (HDC) Model Name L Model Name L Model Name L AHACAB06-5A 0.6 AHACABA5-5A 15.0 AHACABG0-5A 70.0 AHACAB10-5A 1.0 AHACABB0-5A 20.0 AHACABH0-5A 80.0 AHACAB15-5A 1.5 AHACABC0-5A 30.0 AHACABJ0-5A 90.0 AHACAB30-5A 3.0 AHACABD0-5A 40.0 AHACABK0-5A 100.0 AHACAB50-5A 5.0 AHACABE0-5A 50.0 UC-ET010-13B 1.0 AHACABA0-5A 10.0 AHACABF0-5A 60.0 UC-ET010-15B 1.0 L Cable (MIL) Cable (MIL) Model Name L Model Name L UC-ET010-24B 1.0 UC-ET010-24D 1.0 UC-ET020-24B 2.0 UC-ET020-24D 2.0 UC-ET030-24B 3.0 UC-ET030-24D 3.0 L L Cables (RJ45) Model Name L Model Name L Model Name L UC-CMC003-01A 0.3 UC-EMC003-02A 0.3 UC-EMC003-02B 0.3 UC-CMC005-01A 0.5 UC-EMC005-02A 0.5 UC-EMC005-02B 0.5 UC-CMC010-01A 1.0 UC-EMC010-02A 1.0 UC-EMC010-02B 1.0 UC-CMC015-01A 1.5 UC-CMC020-01A 2.0 UC-EMC020-02A 2.0 UC-EMC020-02B 2.0 UC-CMC030-01A 3.0 UC-EMC030-02B 3.0 UC-CMC050-01A 5.0 UC-EMC050-02A 5.0 UC-EMC050-02B 5.0 UC-CMC100-01A 10.0 UC-EMC100-02A 10.0 UC-EMC100-02B 10.0 UC-CMC200-01A 20.0 UC-EMC200-02A 20.0 8 L 8 1 1 27 Cable (DB37) Cables (Fiber Optic) Model Name L Model Name L UC-ET010-33B 1.0 UC-FB010-01A 1.0 UC-FB030-01A 3.0 UC-FB010-02A 1.0 UC-FB030-02A 3.0 L Cable (MIL) Model Name L UC-ET010-24A 1.0 A1 B1 A2 B2 Cable (MIL) Model Name L UC-ET010-24C 1.0 L 500±10 28 L B B L Dimensions Dimensions are in m CANopen Distribution Box CANopen Distribution Box Model Name H W Model Name H W TAP-CN01 87 66.5 TAP-CN03 87 66.5 W W H H CANopen Distribution Box Fiber Optics Modules for Backplanes Model Name H W Model Name H W D TAP-CN02 87 96.5 AHAADP01EF-5A 86.5 48 20.2 AHAADP02EF-5A 86.5 48 20.2 W H H W 29 D Accessory Selection for High-density Modules Model Name AH32AM10N-5B UC-ET010-33B UB-10-ID32B 32AM10N 0 1 2 3 5 4 7 6 8 9 10 11 12 13 14 15 0 1 8 9 10 11 12 13 14 15 2 3 5 4 7 6 24VDC 5mA Model Name AH32AM10N-5C UC-ET010-24A UB-10-ID32A 32AM10N 0 1 8 9 10 11 12 13 14 15 0 1 2 3 8 9 10 11 12 13 14 15 2 3 4 4 5 6 5 7 7 6 UC-ET010-24B / UC-ET020-24B / UC-ET030-24B 24VDC 5mA Model Name AH64AM10N-5C UC-ET010-24A UB-10-ID32A 64AM10N 1 2 8 0 9 10 0 1 2 3 8 9 10 3 0 4 5 6 7 11 12 13 14 15 4 5 6 7 11 12 13 14 15 -3 4 -7 UC-ET010-24B / UC-ET020-24B / UC-ET030-24B 24VDC 5mA 30 x2 Accessory Selection for High-density Modules Model Name AH32AN02T-5B UC-ET010-33B 1 UB-10-OR32A (for relay output) 32AN02T 2 0 1 8 9 10 11 12 13 14 15 3 4 4 5 6 7 1 9 10 11 12 13 14 15 2 3 5 0 8 6 7 OR 2 UB-10-OT32B (for transistor output) 1 UB-10-OR32B (for relay output) 12~24VDC 0.1A Model Name AH32AN02P-5B UC-ET010-33B 32AN02P OR 2 12~24VDC 0.1A 31 UB-10-OT32B (for transistor output) Model Name AH32AN02T-5C 32AN02T 0 1 8 9 10 11 12 13 14 15 2 0 1 8 9 10 11 12 13 14 15 2 3 3 4 4 5 5 6 6 7 A-1 UC-ET010-24C A-2 UC-ET010-24D /  UC-ET020-24D / UC-ET030-24D UB-10-OR16A (for relay output) 7 OR 12~24VDC 0.1A B-1 UC-ET010-24A B-2 UC-ET010-24B /  UC-ET020-24B / UC-ET030-24B A-1 UC-ET010-24C A-2 UC-ET010-24D /  UC-ET020-24D / UC-ET030-24D   UB-10-OT32A (for transistor output) Model Name AH32AN02P-5C 32AN02P 0 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 0 1 8 9 10 11 12 13 14 15 2 3 4 5 6 UB-10-OR16B (for relay output) 7 OR 12~24VDC 0.1A B-1 UC-ET010-24A B-2 UC-ET010-24B /  UC-ET020-24B / UC-ET030-24B 32 UB-10-OT32A (for transistor output) Accessory Selection for High-density Modules Model Name AH64AN02T-5C A-1 UC-ET010-24C  A-2 UC-ET010-24D /  UC-ET020-24D / UC-ET030-24D 64AN02T 0 1 2 8 9 10 0 1 2 8 9 10 3 4 5 6 7 11 12 13 14 15 3 4 5 6 UB-10-OR16A (for relay output) x2 7 11 12 13 14 15 4 -7 0- 3 OR B-1 UC-ET010-24A B-2 UC-ET010-24B /  UC-ET020-24B / UC-ET030-24B UB-10-OT32A (for transistor output) x2 12~24VDC 0.1mA Model Name H64AN02P-5C 64AN02P 0 1 2 8 9 10 0 1 2 8 9 10 3 4 5 6 7 A-1 UC-ET010-24C A-2 UC-ET010-24D /  UC-ET020-24D / UC-ET030-24D  11 12 13 14 15 3 4 5 6 UB-10-OR16B (for relay output) x2 7 11 12 13 14 15 0-3 4- 7 OR B-1 UC-ET010-24A   B-2 UC-ET010-24B /  UC-ET020-24B / UC-ET030-24B  12~24VDC 0.1mA 33 UB-10-OT32A (for transistor output) x2 Model Name AH04HC-5A UC-ET010-13B AH10PM-5A UC-ET010-15B UB-10-IO16C Model Name 34 UB-10-IO24C Accessory Selection for High-density Modules Model Name AH15PM-5A UC-ET010-15B UB-10-IO34C 15 Model Name AH20MC-5A UC-ET010-13B UB-10-IO16C Model Name AH08EMC-5A AH10EMC-5A AH20EMC-5A UC-ET010-13B 10EMC RUN ERROR ETH CN1 EtherCAT STOP RUN Ethernet EtherCAT Micro SD 35 UB-10-IO22C Ordering Information CPU Modules Model Local I/O points Program capacity Data register D / L / B (note) AHCPU 500-RS2 768 32k steps (128 KB) 16k / 16k / 512k words 128 0 0.1 2 w 768 48k steps (196 KB) 24k / 24k / 512k words 512 0 0.02 2.9 w 32k / 32k / 1,024k words 256 1 0.1 2w  AHCPU 501-RS2 AHCPU 64k steps 1,280 (256 KB)  510-RS2 LD Power Function Extension execution consumption blocks backplane speed (μs) (Internal) Specifications ▪▪Built-in RS-232 / 422 / 485 multi-modes communication port x 2 (RS-232: 115.2 kbps /  RS-422 / 485: 921.6 kbps) ▪▪Built-in SD card slot (supports max. 2 GB for AHCPU5_0 or 32 GB for AHCPU5_1) ▪▪Built-in Mini-USB programming port AHCPU 96k steps 1,280 (384 KB) 511-RS2 48k / 48k / 1,024k words 1,024 1 0.02 2.9 w ▪▪System diagnosis /  status light  /  online editing and debug functions ▪▪PLC Link automatic data exchange function ▪▪Modbus RTU / ASCII AHCPU 128k steps 64k / 64k / 2,048k 2,304 (512 KB) words 520-RS2 512 3 0.1 2 w ▪▪LD / SFC / FBD / IL / ST languages ▪▪256 interrupts (Timed / IO / External /  Low voltage / Communication) ▪▪2,048 timers and counters AHCPU 521-RS2 192k steps 2,304 (768 KB) 96k / 96k / 2,048k words ▪▪No battery required 2,048 3 0.02 2.9 w ▪▪RTC function (max. 30 days after power off) ▪▪CPU RAM / ROM capacity AHCPU5_0: 32 MB / 8 MB AHCPU5_1: 128 MB / 128 MB AHCPU 256k steps 64k / 64k / 4,096k 4,352 (1 MB) words 530-RS2 1,024 7 0.1 2 w 384k steps 128k / 128k / 4,096k AHCPU 4,352 (1.5 MB) words 531-RS2 4,096 7 0.02 2.9 w Note: Data Register B is for the use of function blocks. 36 ▪▪CPU clock AHCPU5_0: 133 MHz AHCPU5_1: 800 MHz Certificates Accessory Selection for High-density Modules CPU Modules Model AHCPU 500-EN AHCPU 501-EN Local Program I/O capacity points Data register D / L / B (note) 768 32k steps (128 KB) 16k / 16k / 512k words 768 48k steps (196 KB) 24k / 24k / 512k words AHCPU 1,280 510-EN 64k steps (256 KB) LD Power Function Extension execution consumption blocks backplane speed (μs) (Internal) 128 512 0 0 0.1 0.02 2 w 2.9 w Specifications ▪▪Built-in RS-232 / 422 / 485 multi-modes communication port x1 (RS-232:115.2 kbps /  RS-422 / 485: 921.6 kbps) ▪▪Built-in Ethernet communication port (100 Mbps) ▪▪Built-in SD card slot (supports max. 2 GB for AHCPU5_0 or 32 GB for AHCPU5_1) ▪▪Built-in Mini-USB programming port 32k / 32k / 1,024k words 256 1 0.1 2 w ▪▪System diagnose /  status light / online editing and debug functions ▪▪PLC Link automatic data exchange function AHCPU 1,280 511-EN AHCPU 2,304 520-EN 96k steps (384 KB) 48k / 48k / 1,024k words 128k steps (512 KB) 64k / 64k / 2,048k words 1,024 512 1 3 0.02 0.1 2.9 w 2 w ▪▪Modbus RTU / ASCII, Modbus TCP ▪▪DNP3 (AHCPU521-DNP only) ▪▪EtherNet/IP (AHCPU5_1-EN only) - Scanner & Adapter mode - Supports I/O connection & explicit message - Connections: TCP = 32 ~ 128; CIP = 64 ~ 256 - RPI: 1 ~ 1,000ms - 250 words / connection ▪▪LD / SFC / FBD / IL / ST languages AHCPU 5212,304 EN / DNP (note 2) 192k steps (768 KB) 96k / 96k / 2,048k words ▪▪256 interrupts (Timed / IO / External /  Low voltage / Communication) 2,048 3 0.02 2.9 w ▪▪2,048 timers and counters ▪▪No battery required ▪▪RTC function (max. 30 days after power off) AHCPU 4,352 530-EN AHCPU 4,352 531-EN 256k steps (1MB) 64k / 64k / 4,096k words 384k 128k / 128k / 4,096k steps words (1.5 MB) 1,024 7 0.1 2 w ▪▪NTP network time correction function ▪▪WEB / E-mail / IP Filter function ▪▪CPU RAM / ROM capacity AHCPU5_0: 32 MB / 8 MB AHCPU5_1: 128 MB / 128 MB 4096, 7 Note 1 : Data Register B is for the use of function blocks. Note 2 : Please contact our distributors for release date. 37 0.02 2.9 w ▪▪CPU clock AHCPU5_0: 133 MHz AHCPU5_1: 800 MHz Certificates Redundant CPU Modules Model Local Data LD Power Program Function Extension I/O register D / L / B execution consumption capacity blocks backplane points (note) speed (μs) (Internal) Specifications ▪▪Built-in RS-232 / 485 multi-modes communication port x1 (RS-232:115.2 kbps /  RS-485: 921.6 kbps) ▪▪Built-in Ethernet communication port (100 Mbps) ▪▪Built-in micro SD slot (supports max. 32 GB) ▪▪Built-in Mini-USB programming port ▪▪System diagnosis / status light / online editing and debug functions ▪▪PLC Link automatic data exchange function ▪▪Modbus RTU / ASCII, Modbus TCP AHCPU 560-EN2 4,352 1M steps 256 k / 256 k / 4,096 k (4 MB) words 4,096 7 0.02 4.5 w ▪▪EtherNet/IP - Scanner & Adapter mode - Supports I/O connection & explicit message - Connections: TCP = 128; CIP = 256 - RPI: 1 ~ 1,000 ms - 250 words / connection ▪▪LD / SFC / FBD / IL / ST languages ▪▪256 interrupts (Time d / IO / External /  Low voltage / Communication) ▪▪Redundant mode only supports timed interrupt ▪▪2,048 timers and counters ▪▪No battery required ▪▪RTC function (max. 30 days after power off) ▪▪NTP network time correction function ▪▪WEB / E-mail / IP Filter function ▪▪Supports redundant system - CPU switch-over time: 20 ms - Built-in sync. function and no specific sync. module required (needs fiber optic module) ▪▪CPU RAM/ROM capacity: 256 MB / 128 MB ▪▪CPU clock: 1 GHz 38 Certificates Ordering Information Power Supply Modules Model Power input Output AHPS05-5A 100 ~ 240 VAC 50 / 60Hz 60W AHPS15-5A 24 VDC 36W Specifications Certificates ▪▪Power supply for the modules on the racks ▪▪LED power indicator ▪▪Provides external DC power abnormal signal detection input and triggered interrupt function Main Backplanes Model Slot Power consumption (Internal) AHBP04M1-5A 4 0.01 w AHBP06M1-5A 6 0.01 w AHBP08M1-5A 8 0.01 w AHBP12M1-5A 12 0.01 w AHBP04MR1-5A 4 0.2 w AHBP06MR1-5A 6 0.2 w AHBP08MR1-5A 8 0.2 w AHBP00M2-5A 0 1.41 w AHBP03M2-5A 3 1.41 w AHBP05M2-5A 5 1.41 w AHBP07M2-5A 7 1.41w Specifications Certificates ▪▪Supports CPU modules ▪▪Supports remote I/O communication modules (RTU) ▪▪Built-in communication port for extension backplanes ▪▪Slot spaces are not occupied by Power / CPU / RTU modules ▪▪Supports redundant power (AHBPxxMR1-5A only) ▪▪Supports AHxxEMC-5A installed on CPU slot only (Do not support CPU / RTU modules) ▪▪Built-in serial communication port ▪▪Slot spaces are not occupied by Power / CPU ▪▪No need to install AH power modules (AHBP00M2-5A only) Extension Backplanes Model Slot Power consumption (Internal) AHBP06E1-5A 6 1.41 w AHBP08E1-5A 8 1.41 w Specifications ▪▪For main backplane extension ▪▪Built-in communication port for extension backplanes ▪▪Slot spaces are not occupied by power modules AHBP06ER1-5A AHBP08ER1-5A 6 1 w 8 1 w ▪▪Supports redundant ext. ports (AHBPxxER1-5A only) ▪▪Supports redundant power (AHBPxxER1-5A only) 39 Certificates Digital I/O Modules (Input) Model Points Signals Terminal block type Power consumption (Internal /  External) Accessories (optional) AH16AM10N-5A 16 24 VDC 5 mA JIS removable terminal block 0.1 w / 1.9 w - AH16AM30N-5A 16 120 ~ 240 VAC 4.5 ~ 9 mA JIS removable terminal block 0.1 w / - - 32 24 VDC 5 mA EU removable terminal block 0.2 w / 3.8 w AH32 AM10N-5A ▪▪Hot-swapping function - ▪▪Individual LED status indicator 32 24 VDC 5 mA DB37 0.2 w / 3.8 w AH32 AM10N-5C 32 24 VDC 5 mA MIL 0.2 w / 3.8 w 24 VDC 3.2 mA MIL 64 Certificates ▪▪PNP / NPN mixed mode design AH32AM10N-5B AH64AM10N-5C Specifications 0.2 w / 4.9 w UC-ET010-33B  UB-10-ID32B  UC-ET010-24A UC-ET010-24B UC-ET020-24B ▪▪PNP / NPN mixed mode design UC-ET030-24B UB-10-ID32A ▪▪Hot-swapping function ▪▪Individual LED status indicator (32 points) ▪▪PNP / NPN mixed mode design ▪▪Hot-swapping function ▪▪Individual LED status indicator ▪▪I/O interuuption function AH16AR10N-5A 16 JIS removable terminal block 24 VDC 5 mA 0.5 w / 1.9 w ▪▪Rising / falling-edge trigger modes - ▪▪Signal time-delay setting for 0.1 / 0.5 / 3 / 15 / 20 ms ▪▪Provides user-defined option for signal time-delay setting (Unit: 0.1ms) Digital I/O Modules (Mixed) Model Inputs Outputs Input signals Output signals Terminal block type Power consumption (Internal /  External) AH16 AP11R5A 8 8 24 VDC 5 mA Relay 240 VAC /  24 VDC 2 A JIS removable terminal block 1.1 w / - 8 24 VDC 5 mA NPN (Sink) 12 ~ 24 VDC 0.5A JIS removable terminal block 24 VDC 5 mA PNP (Source) 12 ~ 24 VDC 0.5A JIS removable terminal block AH16 AP11T-5A AH16 AP11P5A 8 8 8 Specifications ▪▪PNP /  NPN mixed mode design ▪▪Hot-swapping function 40 0.2 w / 0.2 w 0.2 w / 0.2 w ▪▪Individual LED status indicator ▪▪Supports keep-last-value function when CPU shuts down Certificates Ordering Information Digital I/O Modules (Output) Model Points Signals Terminal block type Power consumption (Internal /  External) Accessories (optional) AH16 AN01R5A 16 Relay 240 VAC / 24 VDC 2 A JIS removable terminal block 2.1 w / - - AH16 AN01T5A 16 NPN (Sink) 12 ~ 24 VDC 0.5A JIS removable terminal block 0.2 w / 0.4 w - AH16 AN01P5A 16 PNP (Source) 12 ~ 24 VDC 0.5A JIS removable terminal block 0.2 w / 0.4 w - AH16 AN01S5A 16 TRIAC 120 / 240 VAC 0.5A JIS removable terminal block 0.6 w / - - AH32 AN02T5A 32 NPN (Sink) 12 ~ 24 VDC 0.1 A EU removable terminal block 0.4 w / 0.8 w - AH32 AN02P5A 32 PNP (Source) 12 ~ 24 VDC 0.1 A EU removable terminal block 0.4 w / 0.8 w AH32 AN02T5B 32 NPN (Sink) 12 ~ 24 VDC 0.1 A DB37 0.4 w / 0.8 w UC-ET010-33B UB-10-OR32A UB-10-OT32B AH32 AN02P5B 32 PNP (Source) 12 ~ 24 VDC 0.1 A DB37 0.4 w / 0.8 w UC-ET010-33B UB-10-OR32B UB-10-OT32B 32 NPN (Sink) 12 ~ 24 VDC 0.1 A 0.4 w / 0.8 w UC-ET010-24A UC-ET010-24B UC-ET020-24B UC-ET030-24B UC-ET010-24C UC-ET010-24D UC-ET020-24D UC-ET030-24D UB-10-OR16A UB-10-OT32A 32 PNP (Source) 12 ~ 24 VDC 0.1 A 0.4 w / 0.8 w UC-ET010-24A UC-ET010-24B UC-ET020-24B UC-ET030-24B UC-ET010-24C UC-ET010-24D UC-ET020-24D UC-ET030-24D UB-10-OR16B UB-10-OT32A 64 NPN (Sink) 12 ~ 24 VDC 0.1 A 0.6 w / 1.5 w UC-ET010-24A UC-ET010-24B UC-ET020-24B UC-ET030-24B UC-ET010-24C UC-ET010-24D UC-ET020-24D UC-ET030-24D ▪▪Hot-swapping function UB-10-OR16A ▪▪Individual LED status UB-10-OT32A 0.6 w / 1.5 w UC-ET010-24A UC-ET010-24B UC-ET020-24B UC-ET030-24B UC-ET010-24C UC-ET010-24D ▪▪Supports keep-last-value function when CPU shuts UC-ET020-24D down UC-ET030-24D UB-10-OR16B UB-10-OT32A AH32 AN02T5C AH32 AN02P5C AH64 AN02T5C AH64 AN02P5C 64 PNP (Source) 12 ~ 24 VDC 0.1 A Specifications ▪▪Hot-swapping function ▪▪Individual LED status indicator MIL MIL MIL MIL ▪▪Supports keep-last-value function when CPU shuts down - 41 indicator (32 points) Certificates Analog I/O Modules (Input) Model Channels Signals Terminal block type Power consumption (Internal /  External) AH04 AD5A 4 0 / 1 V ~ 5 V, ±5 V, 0 V ~ 10 V, ±10 V 0 / 4 mA ~ 20 mA ±20 mA JIS removable terminal block 0.35 w / 1 w AH08 AD5A 8 0 / 1 V ~ 5 V, ±5 V, 0 V ~ 10 V, ±10 V 0 / 4 mA ~ 20 mA, ±20 mA EU removable terminal block 1.5 w / - AH08 AD5B 8 0 / 1 V ~ 5 V, ±5 V, 0 V ~ 10 V, ±10 V JIS removable terminal block 1.9 w / - 0 / 4 mA ~ 20 mA, ±20 mA JIS removable terminal block Specifications Certificates ▪▪Hardware resolution: 16-bit ▪▪Conversion time: 150 µs / channel ▪▪Base error (ambient temp.): Voltage mode ±0.1% Current mode ±0.1% ▪▪Base error (full temp. range): Voltage mode ±0.45% Current mode ±0.2% ▪▪Linearity error (ambient temp.): Voltage mode ±0.07% Current mode ±0.05% ▪▪Linearity error (full temp. range): Voltage mode ±0.12% Current mode ±0.23% ▪▪Hot-swapping function ▪▪Isolated signal design AH08 AD5C 8 ▪▪Diagnosis function 1.6 w / - ▪▪Module status LED indicator ▪▪Supports interrupt function Analog I/O Modules (Output) Power consumption (Internal /  External) Model Channels Signals Terminal block type AH04DA5A 4 0 / 1 V ~ 5 V, ±5 V, 0 V ~ 10 V, ±10 V 0 / 4 mA ~ 20 mA JIS removable terminal block 0.34 w / 2.6 w AH08DA5A 8 0 / 1 V ~ 5 V, ±5 V, 0 V ~ 10 V, ±10 V 0 / 4 mA ~ 20 mA EU removable terminal block 1 w / 5 w AH08DA5B 8 0 / 1 V ~ 5 V, ±5 V, 0 V ~ 10 V, ±10 V JIS removable terminal block 0.25 w / 2.2 w Specifications Certificates ▪▪Hardware resolution: 16-bit ▪▪Conversion time: 150 µs / channel ▪▪Base error (ambient temp.): Voltage mode ±0.02% Current mode ±0.06% ▪▪Base error (full temp. range): Voltage mode ±0.04% Current mode ±0.07% ▪▪Linearity error (ambient temp.): Voltage mode ±0.004% Current mode ±0.01% ▪▪Linearity error (full temp. range): Voltage mode ±0.004% Current mode ±0.01% ▪▪Hot-swapping function AH08DA5C 8 0 / 4 mA ~ 20 mA JIS removable terminal block ▪▪Isolated signal design 0.25 w / 3.7 w ▪▪Diagnosis function ▪▪Module status LED indicator ▪▪Supports interrupt function ▪▪Supports keep-last-value function when CPU shuts down Analog I/O Modules (Mixed) Model AH06XA5A Channels Inputs: 4 Outputs: 2 Signals Input: 0 / 1 V ~ 5 V, ±5 V, 0 V ~ 10 V, ±10 V 0 / 4 mA ~ 20 mA, ±20 mA Terminal block type Power consumption (Internal /  External) Specifications ▪▪Hardware resolution: 16-bit ▪▪Conversion time: 150 μs / channel ▪▪Input accuracy: same as AH04 AD-5A ▪▪Output accuracy: same as AH04DA-5A JIS removable terminal block 0.34 w / 1.4 w ▪▪Hot-swapping function ▪▪Isolated signal design ▪▪Diagnosis function Output: 0 / 1 V ~ 5 V, ±5 V, 0 V ~ 10 V, ±10 V 0 / 4 mA ~ 20 mA ▪▪Module status LED indicator ▪▪Supports interrupt function ▪▪Supports keep-last-value function when CPU shuts down 42 Certificates Ordering Information Temperature Measurement Modules Model Channels Signals Resolution Conversion time Terminal block type 4 (2 / 3 / 4-wire RTD input) Pt100, Pt1000, Ni100, Ni1000, 0 Ω ~ 300 Ω 0.1 ºC / 0.1 ºF 0.1% (0 Ω ~ 300 Ω) 2 / 4-wire: 150 ms / channel 3-wire: 300 ms / channel JIS removable terminal block AH04PT-5A Power consumption (Internal /  External) Specifications Certificates 2w / ▪▪Effective resolution: 16-bit ▪▪Accuracy: ±0.6% (Full Scale) AH04TC-5A 4 Thermocouple input J,K,R,S,T,E,N, ±150 mV 0.1 ºC / 0.1 ºF JIS removable terminal block 200 ms / channel 1.5w / - ▪▪Supports hot-swapping function ▪▪Signal isolated design ▪▪Diagnosis function ▪▪PID function AH08TC-5A AH08PTG5A 8 8 Thermocouple input J,K,R,S,T,E,N, ±150 mV 0.1 ºC / 0.1 ºF (2 / 3 / 4-wire TD input) Pt100, Pt1000, Ni100, Ni1000, 0 Ω ~ 300 Ω 2 / 4-wire: 20 ms 0.1 ºC / 0.1 ºF (fast)   ~  100 ms 0.1% (normal) / channel (0 Ω ~ 300 Ω) 3-wire: 200 ms / channel JIS removable terminal block 200 ms / channel EU removable terminal block ▪▪Module status LED indicator 1.5w / - ▪▪Supports interrupt function ▪▪Supports disconnection detection function ▪▪Fully isolated channel design (AH08PTG-5A) 0.7w / 4w Remote I/O Modules Model Po wer consumption (Internal /  External) Specifications ▪▪DeviceNet remote I/O module AHRTU-DNET5A AHRTU-PFBS5A 0.75 w / 0.72 w 1.9 w / - ▪▪Installing on the main backplane required ▪▪Supports max. speed of 1 Mbps ▪▪Supports AH DIO modules, AIO modules, temperature measurement modules, and the serial communication module AH10SCM ▪▪Module status LED indicator ▪▪Supports 7 extension backplanes ▪▪Max. speed: 12 Mbps ▪▪Diagnosis function ▪▪Supports AH digital I/O modules, analog I/O modules, temperature measurement modules ▪▪Module status LED indicator ▪▪EtherNet/IP remote I/O module ▪▪Supports I/O connection & explicit message ▪▪Connections: TCP=48 ; CIP=96 2.2 w /  - ▪▪Diagnosis function ▪▪PROFIBUS-DP remote I/O module ▪▪Installs on main backplane AHRTU-ETHN5A ▪▪Supports up to 7 extension racks ▪▪Configurable I/O capacity: 122  words for input / 122  words for output ▪▪Installed on main backplane ▪▪Supports 7 extension backplanes ▪▪Diagnosis function ▪▪RPI: 1 ~ 1,000ms ▪▪Module status LED indicator ▪▪PPS: 10,000 ▪▪2 Ethernet ports (switch function) ▪▪250 words / connection ▪▪Supports AH digital I/O modules, analog I/O modules, temperature measurement modules 43 ▪▪Configurable I/O capacity: 234 words IN ; 234 words OUT Certificates Network Modules Model Power consumption (Internal /  External) Specifications ▪▪SNMP / E-mail / IP Filter function ▪▪Ethernet communication module (Master / Slave) AH10EN5A 1.6 w / - Certificates ▪▪EtherNet/IP ▪▪100 Mbps communication port × 2 (switch function available) - Scanner & Adapter mode - Supports I/O connection & explicit message ▪▪Ether Link function - Connections: TCP = 64 ; CIP = 64 ▪▪Modbus TCP function - RPI: 1 ~ 1,000ms ▪▪Automatic data exchange function - PPS: 6,400 ▪▪NTP network time correction function - 250 words / connection ▪▪Ethernet communication module (Master / Slave) AH15EN5A 1.6 w / - ▪▪100 Mbps communication port × 2 (switch function available) ▪▪SNMP / E-mail / IP Filter function ▪▪Supports IEC60870 ▪▪Ether Link function ▪▪Modbus TCP function ▪▪Automatic data exchange function ▪▪NTP network time correction function ▪▪Serial communication module (Master / Slave) AH10SCM5A 1.2 w / - ▪▪Full isolation design in power & signal circuits ▪▪Built-in RS-422 / RS-485 with communication port × 2 (multiple modes, 460.8 Kbps) ▪▪Supports user defined communication format (UD Link) ▪▪Modbus RTU / ASCII function available ▪▪Supports PLC Link function ▪▪Supports automatic data exchange function ▪▪Serial communication module (Master / Slave) AH15SCM5A 1w / - ▪▪Full isolation design in power & signal circuits ▪▪Supports BACnet Slave function ▪▪Built-in RS-232 with communication port × 2 (multiple modes, 460.8 Kbps) ▪▪Supports PLC Link function AH10DNET5A ▪▪DeviceNet communication module (Master / Slave) 0.9 w / 0.72 w ▪▪Connects up to 63 slave stations in master mode ▪▪Supports max. speed of 1 Mbps ▪▪Switchable between master and slave modes ▪▪Connects up to 124 slaves ▪▪PROFIBUS-DP master module AH10PFBM5A AH10PFBS5A 2 w / - ▪▪Configurable I/O capacity: 2880 words for input / 2880 words for output ▪▪Supports DPV0 / DPV1 ▪▪Max. speed: 12 Mbps ▪▪PROFIBUS-DP slave module 1 w / - ▪▪Configurable I/O capacity: 100 words for input / 100 words for output ▪▪Supports DPV0 ▪▪Max. speed: 12 Mbps ▪▪CANopen module (Master / Slave) AH10COPM5A 1 w / - ▪▪RIO capacity in master mode: 490 words IN / OUT ▪▪Max. speed: 1 Mbps ▪▪Connects up to 100 slaves in master mode 44 ▪▪Supports hot-swapping function ▪▪Diagnosis function ▪▪Module status LED indicator Ordering Information Motion Control Modules Model Channels   /  Axes  Terminal block type AH02HC-5A 2 EU removable terminal block Power Accessories consumption (optional) (Internal) 2.4 w - Specifications ▪▪High speed counter ▪▪200 kHz input ▪▪UD / PD / AB / 4 AB modes ▪▪Supports interrupt function AH04HC-5A 4 HDC 2.4 w UC-ET010-13B ▪▪High speed counter UB-10-IO16C ▪▪Hot-swapping function ▪▪Diagnosis function ▪▪Module status LED indicator ▪▪Pulse train motion control module AH05PM-5A 2 EU removable terminal block 2.7 w - ▪▪Supports 1MHz output ▪▪Supports 2-axis linear interpolation, 2-axis arc interpolation ▪▪Pulse train motion control module ▪▪Supports 1MHz output (4 axes) 200 kHz output (2 axes) AH10PM-5A 6 HDC 2.7 w UC-ET010-15B ▪▪Supports 2 ~ 6-axis linear interpolation, 2-axis arc interpolation and 3-axis UB-10-IO24C helical interpolation ▪▪Built in Ethernet communication port ▪▪Supports Micro SD card ▪▪Pulse type motion control module ▪▪Supports 1MHz output AH15PM-5A 4 HDC 2.7 w ▪▪Supports 2 ~ 4-axis linear interpolation, UC-ET010-15B 2-axis arc interpolation, 3-axis helical interpolation UB-10-IO34C ▪▪Built-in Ethernet communication port ▪▪Supports Micro SD card ▪▪Supports limit switch (LSP /  LSN) input ▪▪CPU execution speed: LD instruction @ 0.13 μs ▪▪Program capacity: 64k steps ▪▪Data register: D=10k words / W=64k words ▪▪Supports UD / PD / AB / 4 AB input modes ▪▪Built-in Mini USB programming communication port ▪▪Independent programming, program download and execution available ▪▪Hot-swapping function ▪▪Diagnosis function ▪▪Module status LED indicator ▪▪DMCNET communication motion control module (10 Mbps) AH20MC5A ▪▪Min. synchronization time at 12 axes is 1ms 12 HDC 3 w UC-ET010-13B ▪▪Supports 2 ~ 6-axis linear interpolation, UB-10-IO16C 2-axis arc interpolation and 3-axis helical interpolation ▪▪Built in Ethernet communication port ▪▪Supports Micro SD card AH08EMC5A AH10EMC5A ▪▪EtherCAT communication motion control (100 Mbps) 8 ▪▪Min. synchronization time at 8 / 16 / 32 axes is 0.5 / 1 / 2 ms ▪▪Supports 2 ~ 6-axis linear interpolation, 2-axis arc interpolation and 3-axis helical interpolation ▪▪Built in Ethernet communication port 16 HDC AH20EMC5A 3.3 w ▪▪Supports Micro SD card UC-ET010-13B UB-10-IO22C ▪▪Supports EtherNet/IP - Adapter mode - Supports I/O connection & explicit message - Connections: TCP = 16 ; CIP = 32 - RPI: 2 ~ 1,000 ms - PPS: 3,200 - 250 words / connection 32 ▪▪CPU execution speed: LD instruction @ 0.08 μs Note: Supports DIO (except interrupt module), AIO, EMC, MC, PM, HC, COPM and SCM modules. 45 ▪▪Program capacity: 256k steps ▪▪Data register: D=64k words / L=64k words ▪▪Supports UD / PD / AB / 4 AB input modes ▪▪Built-in Mini USB programming communication port ▪▪Hot-swapping function ▪▪Diagnosis function ▪▪Module status LED indicator ▪▪Supports installation on CPU slot of motion backplane and working as CPU (Note) ▪▪Max. quantity of FB instance is 4096 Certificates Software Software Model License Descriptions Compatible Products ISPSoft [V3] - Free PLC programming software AH series , DVP series PLCs COMMGR [V1] - Free Communication management software AH series , DVP series PLCs PMSoft [V2] - Free Motion control programming software AH series , DVP series motion controllers DCISoft [V1] - Free Ethernet configuration software AH series Ethernet / serial communication modules, DVP series built-in Ethernet PLCs, DVP series Ethernet / serial communication modules, IFD series Ethernet modules, CMC series Ethernet cards for Delta motor drives DeviceNet Builder [V2] - Free DeviceNet configuration software AH series DeviceNet modules, DVP series DeviceNet modules, CMC series DeviceNet cards for Delta motor drives CANopen Builder [V2] - Free CANopen configuration software AH series CANopen modules, DVP series built-in CANopen PLCs, DVP series CANopen modules, DVP10MC motion controller SYCON.net [V1] - Free PROFIBUS DP configuration software AH series PROFIBUS DP modules Delta OPC [V1] HASP-20OPC01 Hardware license (USB) Delta OPC server AH series PLCs ECAT Builder [V1] - Free EtherCAT configuration software AH series , DVP series PLCs EIP Builder [V1] - Free EtherNet/IP configuration software AH series , DVP series PLCs 46 Ordering Information Accessories Products Descriptions Models AHACAB06-5A Extension cable for connecting extension backplane Cables I/O extension cable for connecting external terminal modules Specifications Applicable Modules 0.6 m AHACAB10-5A 1.0 m AHACAB15-5A 1.5 m AHACAB30-5A 3.0 m AHBP04M1-5A  AHACAB50-5A 5.0 m AHBP06M1-5A   AHACABA0-5A 10.0 m AHBP08M1-5A  AHACABA5-5A 15.0 m AHBP12M1-5A  AHACABB0-5A 20.0 m AHACABC0-5A 30.0 m AHACABD0-5A 40.0 m AHACABE0-5A 50.0 m AHACABF0-5A 60.0 m AHBP06ER1-5A AHACABG0-5A 70.0 m AHBP08ER1-5A AHBP06E1-5A   AHBP08E1-5A AHBP04MR1-5A AHBP06MR1-5A AHBP08MR1-5A AHACABH0-5A 80.0 m AHACABJ0-5A 90.0 m AHACABK0-5A 100.0 m UC-ET010-24A 1.0 m / MIL UC-ET010-24B 1.0 m / MIL (Shielded) UC-ET020-24B 2.0 m / MIL (Shielded) UC-ET030-24B 3.0 m / MIL (Shielded) UC-ET010-24C 1.0 m / MIL AH32 AN02T-5C  UC-ET010-24D 1.0 m / MIL (Shielded) AH32 AN02P-5C  UC-ET020-24D 2.0 m / MIL (Shielded) AH64 AN02T-5C  UC-ET030-24D 3.0 m / MIL (Shielded) AH32 AM10N-5C  AH32 AN02T-5C  AH32 AN02P-5C   AH64 AM10N-5C   AH64 AN02T-5C  AH64 AN02P-5C AH64 AN02P-5C AH32 AM10N-5B   UC-ET010-33B 1.0 m / DB37 AH32 AN02T-5B  AH32 AN02P-5B AH04HC-5A  AH20MC-5A  UC-ET010-13B 1.0 m / HDC AH08EMC-5A AH10EMC-5A AH20EMC-5A UC-ET010-15B 1.0 m / HDC UC-DN01Z-01A(Note) 305.0 m (Thick / Trunk Cable) Note: - Ordering unit: meter - Not available in Taiwan AH15PM-5A AH10COPM-5A   AH10DNET-5A   AHRTU-DNET-5A   CANopen / DeviceNet cables CANopen / DeviceNet / DMCNET cables AH10PM-5A   UC-DN01Z-02A(Note) 305.0 m (Thin / Drop Cable) UC-CMC003-01A 0.3 m / RJ45 UC-CMC005-01A 0.5 m / RJ45 UC-CMC010-01A 1.0 m / RJ45 UC-CMC015-01A 1.5 m / RJ45 UC-CMC020-01A 2.0 m / RJ45 UC-CMC030-01A 3.0 m / RJ45 UC-CMC050-01A 5.0 m / RJ45 UC-CMC100-01A 10.0 m / RJ45 UC-CMC200-01A 20.0 m / RJ45 47 TAP-CN01   TAP-CN02  TAP-CN03 AH20MC-5A   TAP-CN03 Certificates Accessories Products Descriptions EtherCAT cables (ETG approved) Cables EtherCAT cables Fiber optic cables For digital input modules For digital output modules External terminal modules For motion control modules Models Specifications UC-EMC003-02A 0.3 m / RJ45 UC-EMC005-02A 0.5 m / RJ45 UC-EMC010-02A 1.0 m / RJ45 UC-EMC020-02A 2.0 m / RJ45 UC-EMC050-02A 5.0 m / RJ45 UC-EMC100-02A 10.0 m / RJ45 UC-EMC200-02A 20.0 m / RJ45 UC-EMC003-02B 0.3 m / RJ45 UC-EMC005-02B 0.5 m / RJ45 UC-EMC010-02B 1.0 m / RJ45 UC-EMC020-02B 2.0 m / RJ45 UC-EMC030-02B 3.0 m / RJ45 UC-EMC050-02B 5.0 m / RJ45 Applicable Modules AH08EMC-5A AH10EMC-5A AH20EMC-5A UC-EMC100-02B 10.0 m / RJ45 UC-FB010-01A 1.0m / single-mode / LC connector UC-FB030-01A 3.0m / single-mode / LC connector UC-FB010-02A 1.0m / multi-mode / LC connector UC-FB030-02A 3.0m / multi-mode / LC connector UB-10-ID32 A MIL AH32 AM10N-5C   AH64 AM10N-5C UB-10-ID32B DB37 AH32 AM10N-5B UB-10-OR16 A 16 points relay output (240 VAC / 24 VDC, 2 A) MIL AH32 AN02T-5C  AH64 AN02T-5C UB-10-OR16B 16 points relay output (240 VAC / 24 VDC, 2 A) MIL AH32 AN02P-5C  AH64 AN02P-5C UB-10-OR32 A 32 points relay output (240 VAC / 24 VDC, 2 A) DB37 AH32 AN02T-5B UB-10-OR32B 32 points relay output (240 VAC / 24 VDC, 2 A) DB37 AH32 AN02P-5B UB-10-OT32 A Transistor output MIL AH32 AN02T-5C AH32 AN02P-5C AH64 AN02T-5C AH64 AN02P-5C UB-10-OT32B Transistor output DB37 AH32 AN02T-5B AH32 AN02P-5B UB-10-IO16C HDC AH04HC-5A AH20MC-5A UB-10-IO22C HDC AH08EMC-5A AH10EMC-5A AH20EMC-5A UB-10-IO24C HDC AH10PM-5A UB-10-IO34C HDC AH15PM-5A 48 AHCPU560-EN2 Certificates Ordering Information Accessories Products Terminal resistors Distribution box Dummy modules DIN rail Fiber optics modules for backplanes Descriptions DMCNET terminal resistors (RJ45) Models Specifications ASD-TR-DM0008 CANopen / DeviceNet terminal TAP-TR01 resistors (RJ45) CANopen /  DeviceNet distribution Box TAP-CN01 1 for 2 TAP-CN02 1 for 4 TAP-CN03 1 for 4 (RJ45) To protect empty slots AHASP01-5A Used on DIN rail for rack installation AHADINADP1-5A Used for backplane extension via fiber optics AHAADP01EF-5A (installs at the backplane's lower extension port) ▪▪Optical fiber connector: SC ▪▪Supported optical fiber types: multi- modes, 62.5 / 125 μm or 50 / 125 μm ▪▪Optical fiber  max. length: 2 km Used for backplane extension via fiber optics AHAADP02EF-5A (installs at the backplane's upper extension port) ▪▪Connector: LC ▪▪Fiber optics: Multi-mode ▪▪Max. cable length: 2 km ▪▪Operation temperature: …MMF: -5 ~ 70 ºC …MMFT: -40 ~ 85 ºC LCP-100MMFT Used for redundant CPU LCP-100SMF30 LCP-100SMF30T LCP-100SMF60 LCP-100SMF60T Memory card SD card: 1 GB AHBP04M1-5A  AHBP06M1-5A  AHBP08M1-5A AHBP12M1-5A  AHBP06E1-5A  AHBP08E1-5A AHBP04MR1-5A AHBP06MR1-5A AHBP08MR1-5A AHBP06ER1-5A AHBP08ER1-5A AHBP06E1-5A  AHBP08E1-5A AHBP06ER1-5A AHBP08ER1-5A LCP-100MMF FE SFP Fiber Transceiver Applicable Modules ▪▪Connector: LC ▪▪Fiber optics: Single-mode ▪▪Max. cable length: 30 km ▪▪Operation temperature: …F30: -5 ~ 70 ºC …F30T: -40 ~ 85 ºC ▪▪Connector: LC ▪▪Fiber optics: Single-mode ▪▪Max. cable length: 60 km ▪▪Operation temperature: …F60: -5 ~ 70 ºC …F60T: -40 ~ 85 ºC ▪▪Capacity: 1 GB ▪▪Overwrite: 10,000 times ▪▪Speed (Read / Write) : Max. 18 / 15 MB / s ▪▪Operation temperature: -40 ~ 85 ºC FMC-SD001G 49 AHCPU560-EN2 AHCPU5x0-RS2 / EN AHCPU5x1-RS2  / EN / DNP (AHCPU560-EN2 excluded) Certificates Specification Information General Modules Item Specifications ▪▪Temperature: -20 ~ 60 ºC Operating Conditions ▪▪Relative Humidity: 5 ~ 95% (Non-Condensing) ▪▪IP Rating: IP20 Storage Conditions ▪▪Temperature: -40 ~ 70 ºC ▪▪Relative Humidity: 5 ~ 95% (Non-Condensing) Certificates Ethernet Connection Information Model AHCPU500 / 510 / 520 / 530-EN AHCPU501/ 511 / 521 / 531-EN AHCPU560-EN2 Modbus (Server) Modbus (Client) EtherNet/IP (TCP) EtherNet/IP (CIP) DNP3 DNP3 Spec. 32 16 / 32 / 64 / 128 - - - - - 10,000 events DNP3 level 4, Secure Authentication v5 48 / 64 / 96 /160 /160 (Note) 16 / 32 / 64 /128 / 128 16 / 32 / 64 / 128 / 128 32 / 64 / 128 / 256 / 256 AHCPU521-DNP 96 64 - - Ethernet: 32 (Serial: 16) AH08 / 10 / 20EMC-5A 32 128 16 32 - - AH10EN-5A 128 64 64 64 - - - - 48 96 - - AHRTU-ETHN-5A Note: Firmware version is v2.02 and higher. 50 Industrial Automation Headquarters Delta Electronics, Inc. Taoyuan Technology Center No.18, Xinglong Rd., Taoyuan District, Taoyuan City 33068, Taiwan TEL: 886-3-362-6301 / FAX: 886-3-371-6301 Asia EMEA No.182 Minyu Rd., Pudong Shanghai, P.R.C. Post code : 201209 TEL: 86-21-6872-3988 / FAX: 86-21-6872-3996 Customer Service: 400-820-9595 Sales: Sales.IA.EMEA@deltaww.com Marketing: Marketing.IA.EMEA@deltaww.com Technical Support: iatechnicalsupport@deltaww.com Customer Support: Customer-Support@deltaww.com Service: Service.IA.emea@deltaww.com TEL: +31(0)40 800 3900 Delta Electronics (Shanghai) Co., Ltd. Delta Electronics (Japan), Inc. Tokyo Office Industrial Automation Sales Department 2-1-14 Shibadaimon, Minato-ku Tokyo, Japan 105-0012 TEL: 81-3-5733-1155 / FAX: 81-3-5733-1255 Delta Electronics (Korea), Inc. Seoul Office 1511, 219, Gasan Digital 1-Ro., Geumcheon-gu, Seoul, 08501 South Korea TEL: 82-2-515-5305 / FAX: 82-2-515-5302 Headquarters: Delta Electronics (Netherlands) B.V. BENELUX: Delta Electronics (Netherlands) B.V. De Witbogt 20, 5652 AG Eindhoven, The Netherlands Mail: Sales.IA.Benelux@deltaww.com TEL: +31(0)40 800 3900 DACH: Delta Electronics (Netherlands) B.V. Coesterweg 45, D-59494 Soest, Germany Mail: Sales.IA.DACH@deltaww.com TEL: +49(0)2921 987 0 France: Delta Electronics (France) S.A. 4 Kaki Bukit Avenue 1, #05-04, Singapore 417939 TEL: 65-6747-5155 / FAX: 65-6744-9228 ZI du bois Challand 2, 15 rue des Pyrénées, Lisses, 91090 Evry Cedex, France Mail: Sales.IA.FR@deltaww.com TEL: +33(0)1 69 77 82 60 Delta Electronics (India) Pvt. Ltd. Iberia: Delta Electronics Solutions (Spain) S.L.U Delta Electronics (Thailand) PCL. Carrer Llacuna 166, 08018 Barcelona, Spain Mail: Sales.IA.Iberia@deltaww.com Delta Energy Systems (Singapore) Pte Ltd. Plot No.43, Sector 35, HSIIDC Gurgaon, PIN 122001, Haryana, India TEL: 91-124-4874900 / FAX : 91-124-4874945 909 Soi 9, Moo 4, Bangpoo Industrial Estate (E.P.Z), Pattana 1 Rd., T.Phraksa, A.Muang, Samutprakarn 10280, Thailand TEL: 66-2709-2800 / FAX : 662-709-2827 Delta Electronics (Australia) Pty Ltd. Unit 20-21/45 Normanby Rd., Notting Hill Vic 3168, Australia TEL: 61-3-9543-3720 Americas Delta Electronics (Americas) Ltd. Raleigh Office P.O. Box 12173, 5101 Davis Drive, Research Triangle Park, NC 27709, U.S.A. TEL: 1-919-767-3813 / FAX: 1-919-767-3969 Delta Electronics Brazil São Paulo Sales Office Rua Itapeva, 26 - 3°, andar Edificio Itapeva, One - Bela Vista 01332-000 - São Paulo - SP - Brazil TEL: 55-12-3932-2300 / FAX: 55-12-3932-237 Delta Electronics International Mexico S.A. de C.V. Mexico Office Gustavo Baz No. 309 Edificio E PB 103 Colonia La Loma, CP 54060 Tlalnepantla, Estado de México TEL: 52-55-3603-9200 Ctra. De Villaverde a Vallecas, 265 1º Dcha Ed. Hormigueras – P.I. de Vallecas 28031 Madrid TEL: +34(0)91 223 74 20 Italy: Delta Electronics (Italy) S.r.l. Via Meda 2–22060 Novedrate(CO) Piazza Grazioli 18 00186 Roma Italy Mail: Sales.IA.Italy@deltaww.com TEL: +39 039 8900365 Russia: Delta Energy System LLC Vereyskaya Plaza II, office 112 Vereyskaya str. 17 121357 Moscow Russia Mail: Sales.IA.RU@deltaww.com TEL: +7 495 644 3240 Turkey: Delta Greentech Elektronik San. Ltd. Sti. (Turkey) Şerifali Mah. Hendem Cad. Kule Sok. No:16-A 34775 Ümraniye – İstanbul Mail: Sales.IA.Turkey@deltaww.com TEL: + 90 216 499 9910 GCC: Delta Energy Systems AG (Dubai BR) P.O. Box 185668, Gate 7, 3rd Floor, Hamarain Centre Dubai, United Arab Emirates Mail: Sales.IA.MEA@deltaww.com TEL: +971(0)4 2690148 Egypt + North Africa: Delta Electronics Unit 318, 3rd Floor, Trivium Business Complex, North 90 street, New Cairo, Cairo, Egypt Mail: Sales.IA.MEA@deltaww.com *We reserve the right to change the information in this catalogue without prior notice. DELTA_IA-PLC_AH_C_EN_20200813
AHACAB50-5A
物料型号: - AH系列PLC,包括不同的CPU型号,如AHCPU500-RS2、AHCPU501-RS2等,以及多种输入输出模块和扩展背板。

器件简介: - AH系列PLC是新一代的中型PLC,提供高级应用的自动化解决方案。它具有模块化的硬件结构、高级功能和高度集成的软件。

引脚分配: - 引脚分配信息详细描述了各模块的输入输出点数和类型,例如DIO模块有16点、32点、64点等不同配置。

参数特性: - 包括处理器类型(32位处理器和实时操作系统RTOS)、I/O点数、程序容量、数据寄存器大小、执行速度等。

功能详解: - 描述了AH系列PLC的高级功能,如热插拔、冗余和运动控制功能,以及支持的编程语言和网络配置。

应用信息: - 展示了AH系列PLC在大型工业机械、建筑材料加工、织布机械等不同领域的应用案例。

封装信息: - 提供了CPU模块、背板、网络模块等的尺寸信息,以及电源模块、数字I/O模块、模拟I/O模块等的详细规格。
AHACAB50-5A 价格&库存

很抱歉,暂时无法提供与“AHACAB50-5A”相匹配的价格&库存,您可以联系我们找货

免费人工找货