Delta Compact Modular
Mid-range PLC
AS Series
Flexible, Smart, Friendly - The Best Choice
for a Controller of Automated Equipment
AS Series
The AS Series Compact Modular Mid-range PLC is a high performance multi-purpose
controller designed for all kinds of automated equipment. It features Delta's selfdeveloped 32-bit SoC CPUs for enhanced execution speed (40k steps / ms) and
supports up to 32 extension modules or up to 1,024 inputs / outputs. The AS series
provides accurate positioning control for up to 8 axes via CANopen motion network
and 6 axes via pulse control ( 200 kHz ). It is widely used in diverse automated
equipment such as electronics manufacturing, labeling, food packaging, and textile
machines.
The AS Series Controller is equipped with CANopen and EtherNet/IP network
communication for high-speed data transmission. The professional yet simple editing
software ISPSoft delivers quick hardware and network configuration with
built-in function blocks for different industries. It also provides multi-layer password
protection for enhanced system security.
The AS Series adopts a rackless design and patented DIN rail clips for fast vertical
module installation. The simple shape and dark gray exterior of the AS series help
resist stains and dirt in harsh industrial environments.
1
High Efficiency Computing
03
- Advanced CPU performance
- Optimized execution efficiency
- Optimized I/O update rate
- Permanent data backup, no battery required
Accurate Axis Control
05
- Delta CANopen positioning control
- Simple control instructions
- High-speed pulse positioning control
- High-speed counter
Simple Installation
07
- Easy installation process
- Convenient grounding protection
- Screwless installation procedure
- Loose-proof clip-type terminal block
Industrial Network Solution
09
- EtherNet/IP solution
- Remote I/O solution
- Serial communication solution
Programming and Diagnosis Functions
15
- Modular programming structure
- Convenient editing environment
- Easy hardware configuration and parameter setting
- Complete setting tools
- Multiple password protection
Models and Specifications
22
- Model name explanation
- CPU
- AS Series I/O modules
- High-density modules and accessories
- Dimensions
- Ordering information
2
High Efficiency Computing
Delta's self-developed AS Series CPU provides 32-bit high-performance
computing. As the core of a high-efficiency controller, it helps increase
productivity and adaptability to demanding equipment.
Advanced CPU Performance
■
High speed execution up to 40k steps / ms
(Condition: 40 % LD instruction / 60% MOV instruction)
▪ Max. number of inputs / outputs: 1,024
▪ Program capacity: 128k steps
▪ Data registers: 60k words
LD instruction
25 ns
MOV instruction
0.15 μs
▪ Max. extension ability: 32 modules
3
Floating point
operation instruction
1.6 μs
Trigonometric
function instruction
3.5 μs
Optimized Execution Efficiency
■
General Scanning Method
■
Standard simplex scanning which
sequentially goes through instructions by
fixed schedule operation (e.g. I/O update).
AS Series Scanning Method
Fixed schedule operations will be automatically
processed by CPU background program when
scanning starts. It significantly enhances
execution speed.
It significantly affects overall execution
speed.
Program
Program
Out
In
Program
1 scan time
Out
In
Out
1 scan time
In
1 scan time
Program
Out
Program
Out
In
1 scan time
In
1 scan time
Optimized I/O updates
■
Common in the industry:
PLC module bus update via
serial communication
■
▪ General serial communication: the signal is
sequentially sent from the 1st module to the
last module. The more modules the longer
I/O update time it takes.
0.1 ms
CPU #1
#2
#3
#4
#5
#6
AS Series:
PLC module bus update via
parallel communication
▪ Industrial communication: the signal is sent
via parallel communication. The I/O update
time is not significantly prolonged even with
more modules.
Industrial communication bus greatly
enhances stability and speed.
0.1 ms*n
#n
CPU
The more modules, the slower
update speed
0.1 ms
#1
#2
#3
#4
#5
#6
0.1 ms
#n
Industrial communication bus greatly
enhances stability and speed
Note: The real updating performance will be different by different
extension modules.
Permanent data backup, no battery required
■
Non-volatile memory material
for data backup
■
PLC power off
PLC programs
permanent backup
Latched area
permanent backup
Lithium button battery for Real
Time Clock (RTC) function
Install general
CR 1620
battery
4
PLC power off
RTC
keeps accurate time
Accurate Axis Control Positioning Control Solution
CANopen
DS301
Motion control of max. 8
Delta AC Servo Drives ASDA-A2 Series
■
Positioning control - Delta's CANopen Control
▪ Delivers up to 8-axis CANopen positioning
control with AS-FCOPM communication card
▪ Fast positioning configuration in one initialization
instruction without building CANopen data exchange table
▪ Batch download programmable servo drive
parameters avoids risk of loss
▪ Axis control by instructions provides easy maintenance
and high PLC program readability
■
CANopen
DS301
Controls up to 8
AC Servo Drive
ASDA-A2 Series
Simple control instructions for AC Servo Drive ASDA-A2 Series
▪ Initialization: INITC
▪ Relative positioning: DRVIC
▪ Read and write parameter: COPRW
▪ Acceleration and deceleration: CASD
▪ Constant speed control: PLSVC
▪ Absolute positioning: DRVAC
▪ Start / Stop: ASDON
▪ Homing: ZRNC
ASDA-A2 back and forth motion control in 4 steps
No software required
Without looking up parameters
M0
CASD
M1615
ASDON
M1640
M1
M1615
K1
M1640
DDRVAC
K1
D2
INITC
K1
Step 1 - Initialization
K3000
K9000
Step 2 - Acceleration and deceleration
K1
K1
Step 3 - Start
RST
M0
D0
5
Step 4 - Back and forth
Dynamic modification of
next speed and position.
Pulse
Motion control of max. 6
Delta AC Servo Drives ASDA-B2 Series
■
Positioning control - high-speed pulse
▪ AS332T-A / AS332P-A transistor CPU: 6 axes (or 12 channels) 200 kHz
▪ AS324MT-A differential CPU: 2 axes 4 MHz + 4 axes 200 kHz
▪ Supports positioning planning table for fast positioning planning and path simulation
▪ Choose any given 2 axes for linear and arc interpolation
* Note: Please refer to the product specification section (P.23)
for more information on CPU models
■
AC Servo Drive
ASDA-B2 Series
High-speed counter
▪ Real-time high precision monitoring:
AS332T-A / AS332P-A transistor CPU: 6 channels 200 kHz
AS324MT-A differential CPU: 2 channels 4 MHz / 4 channels 200 kHz
▪ Up to 16 external input interrupts
▪ High-speed counter setting tools
* Note: Please refer to the product specification section (P.23)
for more information on CPU models
Encoder
EH
One-time setup,
easy configuration
Regular
photoelectric sensor
PS-R
6
Flat-type
photoelectric sensor
PS-F
Simple Installation
■
Easy installation design
▪ Space-saving design suitable for installation in control panels
Wiring duct
H:88 mm
Wiring duct
■
Rackless Din-rail
installation
Robust slot and clip interlocking design
De
lta
's
pa
ten
t
▪ Delta patented design
■
1
Fast disassembly
▪ Release the clip ring to easily take
out the module from the front
without moving adjacent modules
2
■
Simple installation process
▪ Press the clip rings and push the module to the desired position until hearing a "click"
to finish installation
Push
7
■
Convenient grounding protection
▪ Install on Din-rail: CPU module and expansion modules can be installed directly on Din-rail
without backplane
▪ Install with screw: pull out the installation clip ring and directly install it on the panel
▪ Both methods are equipped
with ground protection
Ground protection
Top clip ring
■ Screwless
Back clip ring
and time-saving installation
Time-saving installation
Complete I/O wiring in 1 second
■
Robust Loose-proof spring clamp terminal block
▪ The AS Series adopts the full-covered
▪ In commonly used spring clamp terminal
spring clamp design that enhances the
clamping force. When the wire is
pulled-out (red arrow) and the spring
moves up (green arrow), a downward
force is generated (blue arrow) to clamp
the wire.
blocks, the clamping force is determined by
the spring material, which decreases with
the aging of the spring.
The green arrow is the clamping force, and the
red arrow is the pull-out force.
8
Industrial Network Solution
EtherNet/IP Solution
The open industrial Ethernet communication protocol
for real-time control and data collection
▪ Max. connectable slave stations: 32
▪ Max. data transmission: 500 bytes / connection
▪ Performance: slave station data update in 1 scan time
PLC (Built-in EtherNet/IP)
AS300
Industrial Wireless AP / Client
DVW Series
Compact Motor Drive
M300 Series
■
Generic Motor Drive
C Series
Other brand
EtherNet/IP equipment
Flexible network system configuration
• Supports star, linear network topology for fast
expansion and management on production lines
• Compatible with IT network. No independent
network or IT technician required
One cable, one network
• Complete Delta EtherNet/IP solution connects
different equipment via Ethernet cable and
simplify cable preparation
Control
layer
• Replaces traditional 3-layer industrial
network structure with seamless connection
via 100 MB high-speed network
Equipment
layer
■
Linear
Information
layer
• Combines with Delta IES solution to construct IoT
for more automation applications and industrial 4.0
upgrades
• Complete industrial network diagnosis for
shortened debug time
9
Star
DIACloud
Industrial 3G
Cloud Router
DX-2100
Industrial Ethernet Cloud Router
DX-2300
SCADA System Software
DIAView
Energy Management System Software
DIAEnergie
IoT & Industrial Ethernet
Industrial Ethernet Switches
DVS Series
▪ DIACloud platform connection
▪ Redundancy ring recovery time < 20 ms
▪ Industrial class EMC testing
Gigabit Fiber Ring
■
Software integration
• Consistent data exchange
interfaceshortens learning time with fast
system configuration
AS300
EDS
Parameter editing
• Provides Delta equipment parameterlist
for quick parameter matching without
looking into detailed manual
Data exchange
Network topology
• EDS File provides quick connection with
EtherNet/IP products of other brands
■
M300 Series
Accurate data update
• Provides real-time cyclic and acyclic
data transmission and define data
priority between equipment
C Series
Other brand
EtherNet/IP
equipment
Modbus TCP
EtherNet/IP
Fluctuated update frequency
Stable update frequency
-F 60.00
• Establishes multiple CIP links and
define different register priority with
one piece of equipment
-F 60.00
5 ms
10 ms
• Executes data update based on user
RPI. Updates all slave station data in
one scan time
5 ms
5 ms
5 ms
6 ms
• 70% better stability compared with
traditional Modbus TCP
Achieve 70% stability
10
EtherNet/IP Software EIP Builder
Visualized Network
Mapping
▪ Direct network planning
Data Exchange Table
▪ Data exchange via table blanks
filling. PLC programing is not
required
Visualized
Product List
▪ Visualized equipment
selection
Network Mapping
Diagnosis
Data Input / Output
Corresponding Table
IP Management
Function
▪ Real-time network status
▪ Preset data exchange on
corresponding parameters
▪ Connecting equipment editing
on corresponding parameters
▪ Configure all IP address of
all EtherNet/IP products
Parameter List
Data Exchange
Diagnosis
Equipment
Description
Management Function
and device indicators
display
▪ Built-in parameter list of
Delta's products
▪ Data exchange status and error
codes
11
Remote I/O Solution
CANopen Remote I/O
●
●
●
CANopen communication card
AS-FCOPM
Max quantity of RIO stations: 15 stations
Max quantity of IO modules (CPU right
side + RIO (SCM) right side): 32 modules
▪ Max DIO points: 1,024 points
▪ Max quantity of AIO modules: 16 modules
▪ Max quantity of communication modules:
4 modules (Only installed on CPU right side)
▪ Max quantity of IO modules installed on
RIO (SCM) right side: 8 modules
* Note: The AS300 CPU requires this
function card for CANopen remote
I/O communication
AS CPU
SCM module
AS00SCM-A
}
}
}
}
AS-FCOPM can only be installed in slot 2
of the CPU and SCM
▪ When a CPU is installed as AS-FCOPM
in slot 2, then slot 1 can be used to install
another function card except AS-FCOPM
▪ When SCM is working in RIO (RTU) mode,
then slot 1 is disabled
RTU mode
1st station
2nd station
3rd station
15th station
Hardware Configuration
I/O Without Planning
▪ Hardware parameter
▪ Auto-mapping with I/O addresses in CPU
(X,Y, and D)
complete planning
DIO
Visualized I/O Structure
▪ Direct I/O planning
AIO
I/O Product List
▪ Product description and specification
12
Serial Communication Solution
Modbus
●
●
Max. connectable stations: 32
Max. distance: 1.2 Km
RS-232
communication card
AS-F232
AS CPU
Extension
Mode
UD Link
●
●
■
Communication
Extension Module
AS00SCM-A
Max. instructions: 1,000
Max. communication
speed:300 bps ~ 230kbps
RS-422
communication card
AS-F422
Slim PLC
DVP Series
Generic AC
Motor Drive
C Series
Temperature
Controller
DTK Series
RS-485
communication card
AS-F485
SCARA Robot
DRS40L Series
Power Meter
DPM-C530
Other Equipment
Modbus Mode
▪ Easy data exchange configuration
Compact Modular
Mid-range PLC
AS PLC
Creating
Table
Standard Type PLC
DVP-ES2 Series
On-site deployment
ISPSoft Data Exchange Table
Generic AC
Motor Drive
C Series
13
Temperature
Controller
DTK Series
Power Meter
DPM-C530
■
Real-time history log diagnosis
▪ AS00SCM stores 2k bytes history log.
SCMSoft directly displays the log for
real-time communication status
monitoring with no additional
monitoring software required
■
即時歷史紀錄診斷
一鍵上傳SCMSoft通訊紀錄,Max: 2k bytes
UD Link Mode (User-defined)
▪ Easy connection to end equipment of special communication protocols
Traditional programming structure
Connection to end equipment of special
communication protocols
Instruction receiving, accessing, editing,
transmitting, sequence control
- Editing the transmitting / receiving packets via SCMSoft.
Format exchange and checksum calculation via
AS00SCM
- Packet content auto-combination for logic control in PLC,
reducing PLC program complexity
- Max. 1,000 transmitting / receiving packets
??
Instruction execution
sequence planning
User-defined communication
format editing
14
Programming and
Diagnosis Functions
ISPSoft IEC Programming Software
Easy operation greatly enhances efficiency
Data Tracer / Logger
COMMGR
HWCONFIG
▪ Data log and time-sequential
▪ Communication interface
▪ Hardware configuration
analysis
manager
Positioning Planning
Tool
and parameter setting
EIP Builder
▪ EtherNet/IP network
configuration
▪ Table-structured position planning
CARD Utility
CANopen Builder
▪ Data backup tool
▪ CANopen network
configuration
15
Modular Program Structure
■
Traditional program structure
■
Errors are often found in large-scale
programs under a traditional structure.
It's hard to debug with increased
maintenance cost.
Modular program structure
Programming organization unit
(POU) enables easy management
in large-scale programs with high
development efficiency.
Step 1
▪ Main program (Cyclic)
.
.
Step 1
.
.
Step 2
.
.
Step 2
.
.
Different programming units are
jointly developed by different engineers,
enhancing development efficiency
Step 3
.
.
Step 3
.
.
▪ Pause execution of POUs
Temporarily stop the function of certain
POU for debug and maintenance
▪ Interrupt subprogram
Step 4
.
.
Step 4
.
.
▪ General subprogram
FB A
SubprogramA
.
.
.
.
Subprogram B
FB B
.
.
■
▪ Joint development
.
.
▪ Individual encryption
POU can be encrypted individually to
protect know-how and intellectual
property
Modular Program Structure
▪ Task manager
Display
panel of task
manager
Plan the execution sequence of POUs and define the nature of the
tasks (cyclical or interruptive)
▪ POU management
Manage all POUs via project tree and support POU import / export for
joint development or other uses
▪ User library
Built-in variety of Delta developed FBs. Users can add frequently used
FBs to the library for future use.
16
Convenient Programming
▪ User-defined data type
▪ On-line programming / update
In addition to basic data types, users
can define structures and enumerations
for flexible programming
Supports program editing in monitoring
mode and program updates during
equipment operation for convenient
debugging and maintenance
▪ Debugging mode
Supports breakpoints, single step
execution and other functions to
enhance debugging efficiency
Various Programming Languages
▪ Support multiple programming languages in the same project
▪ Ladder Diagram (LD)
▪ Structured Text (ST)
ISPSoft provides a programming interface with the
widely used LD language for faster programming
Similar programming method to advanced programming
language C or PASCAL. ST provides more convenient
editing for complicated
expression
▪ Continuous Function Chart (CFC)
▪ Sequential Function Chart (SFC)
CFC provides more advanced applications than FBD.
It supports data feedback, direct display of data stream
and execution sequence for motion control and
sequence-centered application
Direct and easy expression
for the steps in flow charts
for applications that require
process control
Note: ISPSoft V3.01 supports CFC language
17
Easy Hardware Configuration and
Parameter Setting
HWCONFIG
▪ Graphic panel for module configuration
Easy configuration based on connecting equipment
scanning for quick setup
▪ I/O listing
Direct display for corresponding device addresses
after configuration
▪ Parameter setting
Fast parameter setting on controller and modules
without manual reference or programming
Note: Fill the table to configure module parameters quickly.
From / To instruction is not required for module initialization.
▪ Module configuration method
▪ Smart module configuration
Supports an advanced planning tool for
a variety of network modules
Scan the actual
equipment setup
18
Complete Diagnosis Tools for Quick and Effective
System Monitoring
Real-time
Data Logger / Tracer
Stable
Precise
▪ Real-time monitoring:
High-speed tracer for fast sampling within 1 scanning cycle
▪ Stable logging:
Long-time data logger savings of up to 32,768 data records, which can be
transferred to SD card
▪ Precise data capture:
Supports a variety of sampling intervals and trigger modes
▪ Convenient comparison:
Multiple data logs in various data formats can be recorded at the same time
▪ Efficient data analysis:
Supports trend display, scaling, arrangement, merge and measurement
Real-time Module Monitoring
R
E
PS
■ Visualized
32AM 32AM 32AN 32AN
monitoring
Direct monitoring interface provides real-time status
on modules via LED indicators
■ Module
comparison
Real-time inspection of actual module settings to
ensure consistency
■ Error
logs
Immediate inquiry for error messages and logs of
abnormal modules
■ Module
information
Provides model name and version of current modules
19
Convenient Software Wizards for
Effortless Planning
Position planning table
▪ 2D simulation
Intuitive 2D track simulation without complicated calculation
for real-time path planning
▪ Path list
Multiple combinations for positioning modes and tracks
Fast path planning via table-structured planning
▪ Axis parameter setting
Intuitive configuration interface for easy axis
parameter setting without manual reference
■ High-speed
One-time setting
counter setting tool
Counter index will display corresponding
contact point, device and counter
specification once the counting mode
is chosen. Fast planning without manual
reference for enhanced development
efficiency.
■ Data
backup tool - CARD Utility
Friendly guidance interface for easy data backup and restore on programs, parameters
and devices
Various backup and restore methods for
flexible management and operation
Data backup to PC
32GB
20
Data backup to SD card
Multiple Security Protection for Programs
and Data
■
Security: provides 6 types of program protection for data safety
▪ 16-digit password protection on main program
▪ 16-digit password protection on FBs
▪ Access denial mechanism on error login
▪ Data upload protection function
▪ Verification between Project (Programmimg ID) and CPU (PLC ID)
Customer A
Customer B
Program
Downloading
Program
Downloading
Setting Programming
ID in the project
Equipment
Developer
Programming ID to protect
the intellectual property of
equipment developers
Buy AS PLC from
equipment developer
Buy AS PLC from the
market
With the same PLC ID
specified by
the equipment developer
With different PLC ID
▪ Prevention of direct copy from IC
Download
IC duplication prohibited
21
Model Name Explanation
CPU Module
AS332T-A
AS
3
Series
32
Model
T
IO Pts.
-
A
Output type
Type
3: 300
00: None
24: 24 Pts.
N: None
R: Relay
2: 200
18: 18 Pts.
28: 28 Pts.
T: NPN
MT: NPN+Diff.
20: 20 Pts.
32: 32 Pts.
P: PNP
【300 CPU】
A: HDC terminal
B: EU terminal
【200 CPU】
A: Basic
Digital I/O Module
AS08AM10N-A
AS
08
AM
Series
IO Pts.
Classification
0
1
N
Function
-
08: 8 Pts.
AM: Digital input
0: No input
0: No output
N: No output
16: 16 Pts.
AN: Digital output
1: DC input (24 V)
1: 0.5 A transistor / 2 A relay output
T: NPN
32: 32 Pts.
AP: Digital input / output
2: 0.1 A transistor output
P: PNP
64: 64 Pts.
A: Basic
Motion Module
AS04AD-A
AS02PU-A
04
Series
Type
R: Relay
Analog I/O Module
AS
A
Output type
AD
IO Channels
A
AS
Type
Series
-
Classification
02
PU
IO Channels
04: 4-channel
AD: Analog input
A: Voltage / Current
02: 2-channel
06: 6-channel
DA: Analog output
B: Voltage
04: 4-channel
08: 8-channel
XA: Analog input / output
C: Current
Temperature & Load Cell Module
A
-
Classification
Type
PU:
Pulse-train output
A: Basic
Communication Module
AS04RTD-A
AS00SCM-A
AS
04
RTD
Series
IO Channels
Classification
A
AS
00
SCM
Type
Series
Function
Classification
-
02: 2-channel
RTD: Platinum resistance thermometer
04: 4-channel
TC: Thermocouple
06: 6-channe
LC: Load cell
A: Basic
-
00: Basement
SCM: Serial
01: Basic
DENT: DeviceNet
A
Function
A: Basic
08: 8-channel
Function Card
Power Supply Module
AS-F232
AS-PS02
AS
Series
-
F
Classification
F: Function card
232
AS
Function
Series
232: RS-232
2AD: 2-channel analog input
422: RS-422
2DA: 2-channel analog output
485: RS-485
EN02: Ethernet
COPM: CANopen
PFN02: PROFINET
22
-
PS
Classification
PS: Power supply
02
Function
02: AC Input (100 ~ 240 V)
02A: AC Input (100 ~ 240 V) +
DC Output (24 V, 0.5 A)
Product Models and
Specifications
AS Series CPU module
High- density I/O expansion accessories
- AS300 CPU
- AS200 CPU
- UC-ET010-24D
- UB-10-ID16A
Power supply module
- AS-PS02
- AS-PS02A
AS Series
programming software
H: 88mm
D: 78mm
USB
- ISPSoft 3.0
Ethernet
RS-485
Delta Industrial
Ethernet Solutions
IES Series
RS-485 ports x 2
- Serial communication port
CPU Module
Function card x 2
I/O modules
- AS-F232
- AS-F422
- AS-F485
- AS-F2AD
- AS-F2DA
- AS-FCOPM
- Digital I/O module
- Analog I/O module
- Industrial network module
*1: Needs CANopen function card
AS300 CPU
AS300 Series CPU standard specification
Program capacity
128k steps
Basic instruction
25 ns
USB / RS-485 x 2 / EtherNet
Micro
SD Card
Model
Built-in I/O
High speed output
High speed input
AS332T-A
AS332P-A
16DI / 16DO
6 axes 200 kHz
pulse output
6 channels 200 kHz
high-speed counters
AS324MT-A
(Differential)
12DI / 12DO
2 axes + 4 axes 200 kHz
pulse output
2 channels + 4 channels
200 kHz high-speed counters
AS320T-B
AS320P-B
8DI / 12DO
6 axes 200 kHz
pulse output
4 channels 200 kHz
high-speed counters
AS300N-A
-
-
-
AS200 CPU
I/O capability: 1,024
Expansion modules: 32
Function card x 2
EtherNet/IP
Modbus
CANopen
remote I/O(*1)
CANopen DS301
Position Control(*1)
AS200 Series CPU standard specification
Program capacity
64k steps
Basic instruction
25 ns
I/O capability: 1,024
Expansion modules: 32
USB / RS-485 x
2 / EtherNet / CANopen
Micro
SD Card
EtherNet/IP, Modbus
CANopen remote I/O
CANopen DS301
Position Control
Model
Built-in I/O
High speed output
High speed input
AS228T-A
AS228P-A
AS228R-A
16DI / 12DO
6 axes 200 kHz
pulse output
4 channels 200 kHz
high-speed counters
AS218TX-A
AS218PX-A
AS218RX-A
8DI / 6DO
2AI / 2AO
3 axes 200 kHz
pulse output
4 channels 200 kHz
high-speed counters
Power Supply AS-PS02
Power Supply AS-PS02A
Input
100 VAC ~ 240 VAC
Input
100 VAC ~ 240 VAC
24 VDC, 2 A
(for internal bus)
24 VDC, 1.5 A (for internal bus)
24 VDC, 0.5 A (for external I/O)
23
Product Specifications
Model
AS332T-A
AS332P-A
AS324MT-A
AS320T-B
AS320P-B
LD Instruction
25 ns
MOV Instruction
0.15 μs
Elementary
Arithmetic
for Integer
0.92 μs ~ 1.02 μs
Elementary
Arithmetic
for Floating Point
1.69 ~ 1.85 μs
Program Capacity
Memory
Capacity
Data (D)
128k steps
64k words (user parameter storage)
Function Card
The CPUs support up to 2 function cards
Max. Extension Modules
CPU Built-in Differential
Inputs / Outputs
Bit Devices
-
32 modules (max. 16 analog modules / 4 communication modules)
Max. Number of Inputs / Outputs
Inputs / Outputs
64k steps
64k words (including 30k user-defined, 30k software configuration and 4k special registers)
Extension (FR)
CPU Built-in Inputs / Outputs
AS218TX-A
AS218PX-A
AS218RX-A
Ladder Diagram (LD), Structured Text (ST), Continuous Function Chart (CFC),
Sequential Function Chart (SFC)
Programming Languages
Instruction
Processing
Speed
AS228T-A
AS228P-A
AS228R-A
AS300N-A
1,024 points (input & output)
16DI / 16DO
12DI / 12DO
-
4 Inputs + 4
Outputs
8DI / 12DO
-
16DI / 12DO
8DI / 6DO,
2AI / 2AO
-
X
1,024 inputs (X0.0 ~ X63.15)
Y
1,024 outputs (Y0.0 ~ Y63.15)
M
8,192 bits (M0 ~ M8191)
S
2,048 bits (S0 ~ S2047)
Timer
T
512 (T0 ~ T511)
16-bit Counter
C
512 (C0 ~ C511)
32-bit Counter
HC
256 (HC0 ~ HC255)
Pulse Output
Open
collector:
Open collector:
Open collector:
4 axes, 200 kHz
6 axes, 200 kHz
6 axes, 200 kHz
Differential:
2 axes, 4 MHz
-
Open collector:
6 axes, 200 kHz
Open collector:
3 axes, 200 kHz
High-Speed Counter
General:
6 CHs, 200 kHz
General:
4 CHs, 200 kHz
Differential:
2 CHs, 4 MHz
General:
4 CHs, 200 kHz
-
General:
4 CHs, 200 kHz
General:
4 CHs, 200 kHz
DO Type
AS332T-A: NPN
Diff. / NPN
AS332P-A: PNP
AS320T-B: NPN
AS320P-B: PNP
-
AS218TX-A: NPN
AS228T-A: NPN
AS218PX-A: PNP
AS228P-A: PNP
AS218RX-A:
AS228R-A: Relay
Relay
Built-in Communication Port
USB, Ethernet, RS-485 x2
USB, Ethernet, RS-485 x2, CANopen
Communication Protocol
Modbus, Modbus TCP, EtherNet/IP, CANopen
(requires a CANopen function card)
Modbus, Modbus TCP, EtherNet/IP,
CANopen
Ethernet Connection Resource
Modbus (Client / Server): 32 / 32
EtherNet/IP (CIP): 32
Modbus (Client / Server): 16 / 16
EtherNet/IP (CIP): 16
24
Product Specifications
AS332T-A
AS332P-A
Model
Data Backup
(Without Battery)
AS324MT-A
Program
Latched Area
AS228T-A
AS228P-A
AS228R-A
MRAM, no rewriting limit
Max. 64 points
PDO Data Capacity
Max. 2,000 bytes (Read & Write)
PDO Data Capacity
Max. 8 PDO (Read & Write); Max. 8 bytes for each PDO
(Host)
(Slave)
Real-time Clock (RTC)
General Lithium button battery (CR1620)
Self-Diagnosis Function
diagnoses CPU errors, built-in memory errors, and more
AS-PS02 / AS-PS02A
Rated Input
Current
AS300N-A
Flash ROM, rewritable up to 100,000 times
Connectable Salve
Stations
CANopen
DS301
AS320T-B
AS320P-B
110 VAC ~ 240 VAC (±10%)
CPU
24 VDC (±10%)
Extension modules
Electrical and Environmental Specifications
Item
Internal
Power
Consumption
Specifications
CPU
150 mA
Extension
Module
Digital relay output