0
登录后你可以
  • 下载海量资料
  • 学习在线课程
  • 观看技术视频
  • 写文章/发帖/加入社区
会员中心
创作中心
发布
  • 发文章

  • 发资料

  • 发帖

  • 提问

  • 发视频

创作活动
B40SR12424CC

B40SR12424CC

  • 厂商:

    DELTA(台达)

  • 封装:

  • 描述:

    DC/DC CONVERTER 12.4V 298W

  • 数据手册
  • 价格&库存
B40SR12424CC 数据手册
B40SR12424A/B/C/D 12V Output DC/DC Converter, Box Type Package FEATURES  Wide input voltage range, 18~60V  200W Output @ 18V~27V Vin range  300W Output @ 27~60V Vin range  Full Load Efficiency up to 88.3% @48Vin  Intergrated fuse holder (option)  Parallel Connection of multiple units  Box type package with metal base plate  Package Dimension: 190.0x76.0x44.0mm (7.48”x2.99”x1.73”)  Operating Temperature Range - 40°C to +75°C  Input Reverse Polarity Protection  Minimized Inrush current  Input UVLO, Output OCL, Short circuit protection, OVP, OTP  Enable on/off (option)  2250VDC Isolation  IP67 protection for selective model  RoHs Compliant  ISO 9001, ISO 14001 certified manufacturing facility  UL60950  CE Mark  EMC compatible: EN12895, CISPR11 ClassA  Electrical transient conduction: ISO7637-2 The B40SR12424, a wide input voltage range of 18~60V, and single isolated output converter, is the latest product offering from a world leader in power systems technology and manufacturing ― Delta Electronics, Inc. Such box type DCDC converter can provide 300W (200W at Vin < 27V), 12.4V regulated DC output voltage with full load efficiency up to 88.3% @48Vin; The B40SR12424 offers input UVLO, output over current limit, short circuit, output over voltage, over temperature, and input reverse polarity protections, It has an option for intergrated fuse holder and enable on/off function. It also has parallel function; and allows a wide operating temperature range of –40°C to +75°C. With creative design technology and optimization of component placement, this converter possess outstanding electrical and thermal performance, as well as high reliability under extrmely harsh operating conditions. The B40SR12424 meet IP67 protection (refer to “water protection level” specification). Input Characteristics Item Condition Continuous Input Voltage Max Input voltage Min. Typ. Max. Unit 18 48 60 VDC 80 VDC 10 minutes, normal operating Input Under-Voltage Lockout, Turn-On Voltage Threshold 16 17 18 VDC Input Under-Voltage Lockout, Turn-Off Voltage Threshold 14 15 16 VDC 1 2 3 VDC Vin=18V, 100% Load 12.6 13.1 A Vin=24V 85 110 mA Vin=48V 40 70 mA Vin=48V, enable off (C version) 8 Lockout Hysteresis Voltage Maximum Input Current No-Load Input Current Off converter input current 15 mA 0.2 A Max Reverse Polarity Input Voltage 60 VDC Max Inrush current 10 A Reflected input ripple current Internal Input Fuse DS_B40SR12424_10082021 Vin=48V, Vpp Ø 6.35mm*31.75mm 250V/30A Fast-acting fuse E-mail: dcdc@deltaww.com http://www.deltaww.com/dcdc P1 Output Characteristics Item Operating Output Current Range Output Voltage Set Point Output Voltage Ripple and Noise, Output Current Limit Current share accuracy Start-up time(start _up time by Vin) Start-up time(start _up time by Enable) Rise time Output Voltage Protection Conditions Vin=18V~27V Vin=27V~60V Vin=24V,36V,48V, Io=0 Vin=24V, Io=16A Vin=36V,48V, Io=24A Vin=36V, 48V, peak to peak, 20MHz bandwidth RMS Vin=24V, Io=16A peak to peak, 20MHz bandwidth RMS,Vin=24V, Io=16A Vin=24V Vin=36V, 48V Vin=36V, 48V, 24A for each module Vin=48V,full load Vin=48V,full load (for C) General Characteristics Isolation Voltage, Isolation Resistance, Input to Output Isolation Capacitance, Input to Output Switching Frequency MTBF Weight DS_B40SR12424_10082021 16.5 25 13 Vin=24V, 8A to 12A load dynamic, 0.1A/us slew rate Output Voltage Current Transient, positive Vin=36V,48V, 12A to 18A load dynamic, and nagetive voltage step 0.1A/us slew rate Maximum Output Capacitance ESR>10mohm Output overshoot Efficiency @ 100% Load(16A) Vin=24V Efficiency @ 100% Load(24A) Vin=36V Efficiency @ 100% Load(24A) Vin=48V Efficiency @ 60% Load(9.6A) Vin=24V Efficiency @ 60% Load(14.4A) Vin=36V Efficiency @ 60% Load(14.4A) Vin=48V Item Min. 0 0 12.4 12.13 12.0 Conditions Input to Output, Input to Case Ouput to Case Typ. 12.6 12.33 12.2 Max. 16 24 12.8 12.53 12.4 Unit A A V V V 100 160 mV 35 50 mV 60 90 mV 20 18.5 28 6 750 250 30 15 30 20.5 31 10 900 350 50 17 mV A A % mS mS mS V 100 150 mV 100 150 mV 5000 3 µF % % % % % % % Max. 2250 550 Unit VDC VDC MΩ pF KHz Mhours g 86.8 86.5 86.3 87.6 87.8 87.3 88.8 88.5 88.3 89.6 89.8 89.3 Min. Typ. 10 Ta=25ºC, 80%load 6000 175 0.7 900 E-mail: dcdc@deltaww.com http://www.deltaww.com/dcdc P2 Environmental Specifications Parameter Storage Temperature Range Operating Temperature Range Over Temperature Protection Humidity (non condensing) Water Protection Level Vibration Shock Emission Immunity ESD Conditions Ambient Temperature NTC Temperature For model P/N with suffix B IEC 60068-2-6 IEC 60068-2-27 EN12895 EN12895, EN61000-4-3 EN12895, EN61000-4-2 Min. -40 -40 Max. +125 +75 118 Unit ℃ ℃ ℃ % rel. H 95 IP67 10G/15~200HZ/3 PLANES 50G 3 PLANES 30-1000MHz 34-45dBuV/m 10V/m /27-1000MHz AM; 10V/m /900MHz PM Direct: ±2KV ±4KV; Air: ±2KV ±4KV ±8KV Notes 1 2 Specifications typical at Ta=+25℃, nominal input voltage and rated full load output current unless otherwise noted. Specifications are subject to change without notice. ELECTRICAL CURVES Figure 1: Efficiency vs. Output current @ Vin=24V,36V,48V DS_B40SR12424_10082021 Figure 2: Loss vs. Output current @ Vin=24V,36V,48V E-mail: dcdc@deltaww.com http://www.deltaww.com/dcdc P3 ELECTRICAL CURVES Figure 3: Dynamic response to load step 12A~18A with 0.1A/uS slew rate at 48Vin CH1:VOUT, 100mV/div, 500uS/div Figure 4: Vout start up with Vin on at 48Vin,24A Iout, TOP: VIN, 20V/div, 200mS/div BOTTOM: VOUT, 5V/div, 200mS/div Figure 5: Output ripple & noise at 48Vin, 24A Iout CH1: VOUT, 50mV/div, 5uS/div Figure 6: Output over voltage protection at 48Vin, 24A Iout CH1: VOUT, 10V/div, 50mS/div Figure 7: Input current vs. Input voltage @ Vin=18V~27V, 200W; Vin=27V~60V, 300W Figure 8: Output voltage vs. Output current OCL Performance DS_B40SR12424_10082021 E-mail: dcdc@deltaww.com http://www.deltaww.com/dcdc P4 ELECTRICAL CURVES (continous) Figure 9: Output voltage vs. Output current @Vin=48V. Droop function. Figure 10: Current share accuracy vs. Total output current 2 in parallel. Figure 11: Inrush current @ Vin=48V CH1:Iin, 2A/div, 200nS/div Max current 2.7A, I2t=1.24E-7 A²S DS_B40SR12424_10082021 E-mail: dcdc@deltaww.com http://www.deltaww.com/dcdc P5 FEATURES DESCRIPTIONS Output Over-Current Limit and Short Protection The modules include internal output over-current limit (OCL) and short circuit protection (SCP) circuits, the OCL set point is lower than that of the SCP; The response of SCP circuit is much fast than that of the OCL circuit. The slowly increase of the output current will let module enter OCL protection when the current exceeds the OCL set point, while the fast increase of the output current will let module enter SCP when the current exceeds the SCP set point. When the modules enter OCL protection, the output voltage will decrease while the output current is kept constant, the output voltage will soft start to set point when the overload condition is removed. The module will enter hiccup mode when it triggers the SCP set point. The module will try to restart after shutdown. If the overload condition still exists, the module will shut down again. This restart trial will continue until the overload condition is removed. Output Over-Voltage Protection The power module includes an internal output over-voltage protection (OVP) circuit, which monitors the voltage on the output terminals. If this voltage exceeds the OVP set point, the module will shut down, and then restart after a fixed delay time (hiccup mode), please refer to figure8 for detail. Over-Temperature Protection The over-temperature protection consists of circuitry that provides protection from thermal damage. If the temperature exceeds the preset temperature threshold the module will shut down, and all components will not exceed their absolute maximum temperature ratings. The module will restart after the temperature is within specification. Remote On/Off B40SR12424C has Enable control function. This Enable PIN is designed on the primary side of converter, the converter will turn on when the Enable PIN connected to VIN+, and turn off when the Enable PIN connected to VIN- or floating. Figure 12: suggested Enable connection Input Reverse Voltage Protection The input reverse voltage protection is provided by a diode on the input line, the standoff voltage for the reverse protection shall be no less than -60V. DS_B40SR12424_10082021 E-mail: dcdc@deltaww.com http://www.deltaww.com/dcdc P6 DESIGN CONSIDERATIONS Parallel connection of multiple units Two units’ parallel operation is verified, please contact Delta if more than two units need to be paralleled. While parallelling multiple units, the impedance of the cables from unit to junction point of each unit should be within ±5% of each other. Figure 13: suggested parallel connections EMC 80 80 70 70 60 60 50 50 Level in dB米V/ Level in dB米V/ The converter has the internal EMI filters and meet the EMC standards EN12895 30-1000MHz 34-45dBuV/m. The test result is showed as below Conditions: Vin=48V, Io=24A, 10m measure distance 40 30 20 10 0 30M 40 30 20 10 50 60 80 100M 200 300 400 500 Figure 14: test result (Vertical) 800 1G 0 30M 50 60 80 100M 200 300 400 500 800 1G Figure 15: test result (Horizontal) Fuse replacement For the versions with the intergratted the fuse holder, when the fuse needs to be replaced, it can be taked down in an anticlockwise direction by slotted type screwdrivers. Recommended fuse replacement P/N: Littlefuse 0314030.MXP DS_B40SR12424_10082021 E-mail: dcdc@deltaww.com http://www.deltaww.com/dcdc P7 THERMAL CONSIDERATION The thermal curve (Figure17~19) is based on a 250x300x5mm AL table, shown as below figure. Figure 16: Thermal consideration THERMAL CURVE Figure 17: Output Current vs. Ambient temperature @Vin=24V DS_B40SR12424_10082021 E-mail: dcdc@deltaww.com http://www.deltaww.com/dcdc P8 THERMAL CURVE DS_B40SR12424_10082021 Figure 18: Output Current vs. Ambient temperature @ Vin=36V Figure 19: Output Current vs. Ambient temperature @ Vin=48V E-mail: dcdc@deltaww.com http://www.deltaww.com/dcdc P9 THERMAL CONSIDERATION The following figure shows the location to monitor the temperature of base plate. Before customer decides to use this DCDC converter, a thermal evaluation need to be did to make sure the temperature of base plate is lower than that read from below thermal curves (Figure21~23 base on different input voltage). Figure 20: Thermal consideration THERMAL CURVE Figure 21: Output Current vs. Base Plate temperature @Vin=24V DS_B40SR12424_10082021 E-mail: dcdc@deltaww.com http://www.deltaww.com/dcdc P10 THERMAL CURVE DS_B40SR12424_10082021 Figure 22: Output Current vs. Base Table temperature @ Vin=36V Figure 23: Output Current vs. Base Table temperature @ Vin=48V E-mail: dcdc@deltaww.com http://www.deltaww.com/dcdc P11 Mechanical Drawing Mechanical Dimensions Pin Connections Pin Function Description 1 OUTPUT - 2 OUTPUT + 3 INPUT - 4 INPUT +  All dimensions in mm (inches)  Tolerance:X.X±0.5 (X.XX±0.02)  Connector: MOLEX MINI-FIT SrTM Header X.XX±0.25 ( X.XXX±0.010) (MOLEX P/N :42819-4213) B40SR12424A Pin Function Description 1 OUTPUT - 2 OUTPUT + 3 INPUT - 4 INPUT +  All dimensions in mm (inches)  Tolerance:X.X±0.5 (X.XX±0.02)  Connector: MOLEX MINI-FIT SrTM Header X.XX±0.25 ( X.XXX±0.010) (MOLEX P/N :42819-4213)  B40SR12424AC DS_B40SR12424_10082021 Connector kit : Housing: 42816-0412 Terminal: 42815-0042 E-mail: dcdc@deltaww.com http://www.deltaww.com/dcdc P12 Mechanical Drawing Mechanical Dimensions Pin Connections Pin Function Description 1 OUTPUT - 2 OUTPUT + 3 INPUT - 4 INPUT +  All dimensions in mm (inches)  Tolerance:X.X±0.5 (X.XX±0.02)  Connector: Deutsch DTP Receptacles X.XX±0.25 ( X.XXX±0.010) B40SR12424B (DEUTSCH P/N :DTP04-4P) Pin Function Description 1 OUTPUT - 2 OUTPUT + 3 INPUT - 4 INPUT +  All dimensions in mm (inches)  Tolerance:X.X±0.5 (X.XX±0.02)  Connector: Deutsch DTP Receptacles X.XX±0.25 ( X.XXX±0.010) (DEUTSCH P/N :DTP04-4P)  B40SR12424BC DS_B40SR12424_10082021 Connector kit : Housing: DTP06-4S Wedge lock: WP-4S Terminal: 0462-203-12141 E-mail: dcdc@deltaww.com http://www.deltaww.com/dcdc P13 Mechanical Drawing Mechanical Dimensions Pin Connections Pin Function Description 1 OUTPUT - 2 OUTPUT + 3 INPUT - 4 INPUT + 5 ENABLE  All dimensions in mm (inches)  Tolerance:X.X±0.5 (X.XX±0.02) X.XX±0.25 ( X.XXX±0.010)  Connector: MOLEX MINI-FIT SrTM Header (MOLEX P/N :42819-5213) B40SR12424C Pin Function Description 1 OUTPUT - 2 OUTPUT + 3 INPUT - 4 INPUT + 5 ENABLE  All dimensions in mm (inches)  Tolerance:X.X±0.5 (X.XX±0.02)  Connector: MOLEX MINI-FIT SrTM Header X.XX±0.25 ( X.XXX±0.010) (MOLEX P/N :42819-5213)  B40SR12424CC DS_B40SR12424_10082021 Connector kit : Housing: 42816-0512 Terminal: 42815-0042 E-mail: dcdc@deltaww.com http://www.deltaww.com/dcdc P14 Mechanical Drawing Mechanical Dimensions Pin Connections Pin Function Description 1 OUTPUT - 2 OUTPUT + 3 INPUT - 4 INPUT +  All dimensions in mm (inches)  Tolerance:X.X±0.5 (X.XX±0.02) X.XX±0.25 ( X.XXX±0.010)  Connector: MOLEX MINI-FIT SrTM Header (MOLEX P/N :42819-4213) B40SR12424D Pin Function Description 1 OUTPUT - 2 OUTPUT + 3 INPUT - 4 INPUT +  All dimensions in mm (inches)  Tolerance:X.X±0.5 (X.XX±0.02) X.XX±0.25 ( X.XXX±0.010)  Connector: MOLEX MINI-FIT SrTM Header (MOLEX P/N :42819-4213)  B40SR12424DC DS_B40SR12424_10082021 Connector kit : Housing: 42816-0412 Terminal: 42815-0042 E-mail: dcdc@deltaww.com http://www.deltaww.com/dcdc P15 Part Numbering System B Form Factor BBox 40 S R 124 24 A C Input Voltage Number of Outputs Product Series Output Voltage Output Current Option Code Option Fitting 40 18V~60V SSingle RRegular 124 12.4V 24 24A With Built-in fuse holder Enable pin Sealed connector & fuse holder Connector Kit A YES NO NO 1xhousing+ 4 terminals B YES NO YES 1xhousing+ 4 terminals C NO YES NO 1xhousing+ 5 terminals D NO NO NO 1xhousing+ 4 terminals Model List Input Voltage Range B40SR12424(A\B\C\D) Input 18V~60V EFF @48VIN 100% LOAD Output 13.1A 12.4V CONTACT: www.deltaww.com/dcdc Email: dcdc@deltaww.com USA: Telephone: East Coast: 978-656-3993 West Coast: 510-668-5100 Fax: (978) 656 3964 Europe: Phone: +31-20-655-0967 Fax: +31-20-655-0999 24A 88.3% Asia & the rest of world: Telephone: +886 3 4526107 ext 6220~6226 Fax: +886 3 4513485 WARRANTY Delta offers a two (2) years limited warranty. Complete warranty information is listed on our web site or is available upon request from Delta. Information furnished by Delta is believed to be accurate and reliable. However, no responsibility is assumed by Delta for its use, nor for any infringements of patents or other rights of third parties, which may result from its use. No license is granted by implication or otherwise under any patent or patent rights of Delta. Delta reserves the right to revise these specifications at any time, without notice. DS_B40SR12424_10082021 E-mail: dcdc@deltaww.com http://www.deltaww.com/dcdc P16
B40SR12424CC 价格&库存

很抱歉,暂时无法提供与“B40SR12424CC”相匹配的价格&库存,您可以联系我们找货

免费人工找货