0
登录后你可以
  • 下载海量资料
  • 学习在线课程
  • 观看技术视频
  • 写文章/发帖/加入社区
会员中心
创作中心
发布
  • 发文章

  • 发资料

  • 发帖

  • 提问

  • 发视频

创作活动
DRP-24V48W1AZ

DRP-24V48W1AZ

  • 厂商:

    DELTA(台达)

  • 封装:

    -

  • 描述:

    AC/DC CONVERTER 24V 48W

  • 数据手册
  • 价格&库存
DRP-24V48W1AZ 数据手册
TECHNICAL DATASHEET CliQ DIN Rail Power Supply 24V 48W 1 Phase / DRP-24V48W1AZ Highlights & Features • • • • • • • Universal AC input voltage range Power will not de-rate for the entire input voltage range Rugged and compact design (Vibration 5 G, Shock 30 G) Conforms to harmonics current IEC/EN 61000-3-2, Class A Wide operating temperature range -20°C to 70°C Overvoltage / Overcurrent / Over Temperature / Short Circuit Protections Certified according to IEC/EN/UL 62368-1 Safety Standards CB Certified for worldwide use Model Number: DRP-24V48W1AZ Unit Weight: 0.22 kg (0.49 lb) Dimensions (L x W x D): 100 x 32 x 100.6 mm (3.94 x 1.26 x 3.96 inch) General Description The DRP-24V48W1AZ has a power rating of 48W with 24V output voltage. Its rugged plastic casing has a compact body at only 32 mm wide and operates within a wide temperature range from -20°C to 70°C. Like its CliQ predecessors, the DRP-24V48W1AZ comes with universal AC input and complies with major industrial standards like UL 508 (Safety for Industrial Control Equipment), EMI according to EN 55011 (Industrial, scientific and medical (ISM) radio-frequency equipment) and EMS according to EN 61000-6-2 (Immunity for industrial environments). For broader application compatibility, the product is also certified for ITE (Information Technology Equipment) standard according to IEC/EN/UL 60950-1 and IEC/EN/UL 62368-1 Audio/video, Information and Communication Technology Equipment. Model Information CliQ DIN Rail Power Supply Model Number Input Voltage Range Rated Output Voltage Rated Output Current DRP-24V48W1AZ 85-264 Vac (120-375 Vdc) 24 Vdc 2.00 A Model Numbering DR P‒ 24V 48W 1 A Z DIN Rail Power Supply Output Voltage Output Power Single Phase CliQ Series Plastic Case 1 All parameters are specified at 25°C ambient and AC input unless otherwise indicated. www.DeltaPSU.com (September 2021, Rev. 06) TECHNICAL DATASHEET CliQ DIN Rail Power Supply 24V 48W 1 Phase / DRP-24V48W1AZ Specifications Input Ratings / Characteristics Nominal Input Voltage 100-240 Vac Input Voltage Range 85-264 Vac Nominal Input Frequency 50-60 Hz Input Frequency Range 47-63 Hz Nominal DC Input Voltage 125-250 Vdc DC Input Voltage Range* 120-375 Vdc Input Current < 1.40 A @ 115 Vac, < 0.70 A @ 230 Vac Efficiency at 100% Load > 87.0% @ 115 Vac & 230 Vac Max Power Dissipation 0% load 100% load < 0.3 W @ 115 Vac & < 0.5 W @ 230 Vac < 7.0 W @ 115 Vac & 230 Vac Max Inrush Current (Cold Start) < 28 A @ 115 Vac, < 56 A @ 230 Vac Leakage Current < 1 mA @ 240 Vac *Fulfills tested conditions Output Ratings / Characteristics** Nominal Output Voltage 24 Vdc Factory Set Point Tolerance 24 Vdc ± 1% Output Voltage Adjustment Range 22-26 Vdc Output Current 2.00 A (48 W max.) Output Power 48 W Line Regulation < 1.0% (@ 85-264 Vac input, 100% load) Load Regulation < 1.0% (@ 85-264 Vac input, 0-100% load) PARD*** (20 MHz) < 480 mVpp Rise Time < 50 ms @ nominal input (100% load) Start-up Time < 3,000 ms @ nominal input (100% load) Hold-up Time Dynamic Response (Overshoot & Undershoot O/P Voltage) > 10 ms @ 115 Vac, > 60 ms @ 230 Vac (100% load) ± 5% @ 85-264 Vac input, 10-100% load (Slew Rate: 0.1 A/μs, 50% duty cycle @ 5 Hz to 1 KHz) Start-up with Capacitive Loads 1,000 µF Max **For power de-rating from 50°C to 70°C, see power de-rating on page 3. ***PARD is measured with an AC coupling mode, 5 cm wires, and in parallel with 0.1 μF ceramic capacitor. 2 All parameters are specified at 25°C ambient and AC input unless otherwise indicated. www.DeltaPSU.com (September 2021, Rev. 06) TECHNICAL DATASHEET CliQ DIN Rail Power Supply 24V 48W 1 Phase / DRP-24V48W1AZ Mechanical Case Cover / Chassis Plastic Dimensions (L x W x D) 100 x 32 x 100.6 mm (3.94 x 1.26 x 3.96 inch) Unit Weight 0.22 kg (0.49 lb) Indicator Green LED Cooling System Terminal DC OK Convection Input / Output 5 Pins (Rated 300 V/15 A) Wire AWG 20-14 Mounting Rail Standard TS35 DIN Rail in accordance with EN 60715 Noise (1 Meter from power supply) Sound Pressure Level (SPL) < 25 dBA Environment Surrounding Air Temperature Power De-rating Operating -20°C to +70°C Storage -25°C to +85°C Vertical Mounting Operating Humidity -20°C to -10°C de-rate power by 1% / °C, -10°C to 0°C de-rate power by 2% / °C, > 50°C de-rate power by 2.5% / °C 5 to 95% RH (Non-Condensing) Operating Altitude 0 to 2,000 Meters (6,560 ft) Horizontal Mounting Shock Test Non-Operating IEC 60068-2-27, 30 G (300 m/S² for a duration of 18 ms, 1 times per direction, 2 times in total Vibration Non-Operating IEC 60068-2-6, 10 Hz to 150 Hz @ 50 m/S² (5 G peak); 90 min per axis for all X, Y, Z direction Bump Test Operating IEC 60068-2-29, Half Sine Wave: 10 G for a duration of 11 ms, 1,000 times per direction, 6,000 times in total Over Voltage Category III Pollution Degree 2 According to IEC/EN 62477-1 / EN 60204-1 (clearance and creepage distances) Protections Overvoltage < 32.4 V, SELV Output, Latch Mode Overload / Overcurrent > 105~180% of rated load current, Hiccup Mode, Non-Latching (Auto-Recovery) Over Temperature < 75°C Surrounding Air Temperature @ 100% load, Latch Mode Short Circuit Hiccup Mode, Non-Latching (Auto-Recovery when the fault is removed) Internal Fuse at L pin T3.15AH Protection Against Shock Class I with PE* connection *PE: Primary Earth Reliability Data MTBF > 500,000 hrs. as per Telcordia SR-332 I/P: 115 Vac, O/P: 100% load, Ta: 25°C Expected Cap Life Time 10 years (115 Vac & 230 Vac, 50% load @ 40°C) 3 All parameters are specified at 25°C ambient and AC input unless otherwise indicated. www.DeltaPSU.com (September 2021, Rev. 06) TECHNICAL DATASHEET CliQ DIN Rail Power Supply 24V 48W 1 Phase / DRP-24V48W1AZ Safety Standards / Directives Electrical Equipment of Machines EN 60204-1 (over voltage category III) Electrical Equipment for Use in Electrical Power Installations IEC/EN/BS EN 62477-1 Safety Entry Low Voltage SELV (IEC 60950-1) Electrical Safety SIQ Bauart UL/cUL recognized CB Scheme UKCA Industrial Control Equipment UL/cUL listed CSA EN 62368-1 UL 60950-1 and CSA C22.2 No. 60950-1 (File No. E191395) UL 62368-1 and CSA C22.2 No. 62368-1 (File No. E191395) IEC 60950-1, IEC 62368-1 BS EN 62368-1 UL 508 and CSA C22.2 No. 107.1-01 (File No. E315355) CSA C22.2 No. 107.1-01 (File No. 181564) CCC GB9254, GB17625.1 and GB4943.1 仅适用于海拔 2000m 以下地区安全使用 CE In conformance with EMC Directive 2014/30/EU and Low Voltage Directive 2014/35/EU UKCA In conformance with Electrical Equipment (Safety) Regulations 2016 No. 1011 and The Electromagnetic Compatibility Regulations 2016 No. 1091 3.0 KVac Galvanic Isolation 4 Input to Output Input to Ground 1.5 KVac Output to Ground 0.5 KVac All parameters are specified at 25°C ambient and AC input unless otherwise indicated. www.DeltaPSU.com (September 2021, Rev. 06) TECHNICAL DATASHEET CliQ DIN Rail Power Supply 24V 48W 1 Phase / DRP-24V48W1AZ EMC Emissions (CE & RE) Generic Standards: CISPR32, EN/BS EN 55032, KN 32 CISPR11, EN/BS EN 55011, FCC Title 47: Class B Immunity Generic Standards: EN/BS EN 55024, KN 35, EN/BS EN 61000-6-2 Electrostatic Discharge IEC 61000-4-2 Level 3 Criteria A1) Air Discharge: 8 kV Contact Discharge: 6 kV Radiated Field IEC 61000-4-3 Level 3 Criteria A1) 80 MHz-1 GHz, 10 V/M, 80% modulation (1 KHz) 1.4 GHz-2 GHz, 3 V/M, 80% modulation (1 KHz) 2 GHz-2.7 GHz, 1 V/M, 80% modulation (1 KHz) Electrical Fast Transient / Burst IEC 61000-4-4 Level 3 Criteria A1) 2 kV Surge IEC 61000-4-5 Level 3 Criteria A1) Common Mode2): 2 kV Differential Mode3): 1 kV Conducted IEC 61000-4-6 Level 3 Criteria A1) 150 kHz-80 MHz, 10 Vrms Power Frequency Magnetic Fields IEC 61000-4-8 Criteria A1) 30 A/Meter Voltage Dips and Interruptions IEC 61000-4-11 100% dip; 1 cycle (20 ms); Self Recoverable Low Energy Pulse Test (Ring Wave) IEC 61000-4-12 Level 3 Criteria A1) Common Mode2): 2 kV Differential Mode3): 1 kV Harmonic Current Emission IEC/EN/BS EN 61000-3-2, Class A Voltage Fluctuation and Flicker IEC/EN/BS EN 61000-3-3 1) Criteria A: Normal performance within the specification limits 2) Asymmetrical: Common mode (Line to earth) 3) Symmetrical: Differential mode (Line to line) 5 All parameters are specified at 25°C ambient and AC input unless otherwise indicated. www.DeltaPSU.com (September 2021, Rev. 06) TECHNICAL DATASHEET CliQ DIN Rail Power Supply 24V 48W 1 Phase / DRP-24V48W1AZ Block Diagram Device Description 1) 2) 3) 4) 6 Input & Output terminal block connector DC Voltage adjustment potentiometer DC OK control LED (Green) Universal mounting rail system All parameters are specified at 25°C ambient and AC input unless otherwise indicated. www.DeltaPSU.com (September 2021, Rev. 06) TECHNICAL DATASHEET CliQ DIN Rail Power Supply 24V 48W 1 Phase / DRP-24V48W1AZ Dimensions L x W x D: 100 x 32 x 100.6 mm (3.94 x 1.26 x 3.96 inch) Engineering Data Output Load De-rating VS Surrounding Air Temperature Note 1. 2. 3. 4. Fig. 1 7 De-rating for Vertical and Horizontal Mounting Orientation -20°C to -10°C de-rate power by 1% / °C, -10°C to 0°C de-rate power by 2% / °C, > 50°C de-rate power by 2.5% / °C 5. Power supply components may degrade, or be damaged, when the power supply is continuously used outside the shaded region, refer to the graph shown in Fig. 1. If the output capacity is not reduced when the surrounding air temperature exceeds its specification as defined on Page 3 under “Environment”, the device may run into Over Temperature Protection. When activated, the output voltage will go into latch-off mode until the component temperature cools down and the AC power is recycled. In order for the device to function in the manner intended, it is also necessary to keep a safety distance as recommended in the safety instructions while the device is in operation. Depending on the surrounding air temperature and output load delivered by the power supply, the device can be very hot! If the device has to be mounted in any other orientation, please contact info@deltapsu.com for more details. All parameters are specified at 25°C ambient and AC input unless otherwise indicated. www.DeltaPSU.com (September 2021, Rev. 06) TECHNICAL DATASHEET CliQ DIN Rail Power Supply 24V 48W 1 Phase / DRP-24V48W1AZ Output Load De-rating VS Input Voltage  No output power de-rating across the entire input voltage range Assembly & Installation The power supply unit (PSU) can be mounted on 35 mm DIN rails in accordance with EN60715. For Vertical Mounting, the device should be installed with input terminal block at the bottom. For Horizontal Mounting, the device should be installed with input terminal block on the left side. Each device is delivered ready to install. Mounting Snap on the DIN rail as shown on the left: 1. Pull the unit’s DIN rail latch OUT. 2. Tilt the unit slightly upwards, hook the top end onto the DIN rail and push downwards until stopped. 3. Position the bottom front end against the DIN rail. 4. Push the unit’s latch DIN rail IN to lock. Dismounting To uninstall: 1. Pull the unit’s DIN rail latch OUT. 2. Tilt the bottom part of the unit out. 3. Push the unit up and pull out from the DIN rail. In accordance to EN 60950 / UL 60950 and EN 62368 / UL 62368, flexible cables require ferrules. Use appropriate copper cables designed to sustain operating temperature of at least 75°C or more to fulfill UL requirements. For stranded wires it is recommended to use suitable lug to crimp wires. 8 All parameters are specified at 25°C ambient and AC input unless otherwise indicated. www.DeltaPSU.com (September 2021, Rev. 06) TECHNICAL DATASHEET CliQ DIN Rail Power Supply 24V 48W 1 Phase / DRP-24V48W1AZ Safety Instructions  • • • • • • • • • • 9 Vertical Mounting  Horizontal Mounting ALWAYS switch mains of input power OFF before connecting and disconnecting the input voltage to the unit. If mains are not turned OFF, there is risk of explosion / severe damage. To guarantee sufficient convection cooling, please refer to the following instructions to ensure sufficient clearance around the device. Vertical Mounting: 50 mm (1.97 inch) above and below the device as well as a lateral distance of 20 mm (0.79 inch) to other units. Horizontal Mounting: 50 mm (1.97 inch) above and below the device as well as a lateral distance of 50 mm (1.97 inch) to other units. Note that the enclosure of the device can become very hot depending on the surrounding air temperature and load of the power supply. Risk of burns! The main power must be turned off before connecting or disconnecting wires to the terminals! DO NOT insert any objects into the unit. Hazardous voltages may be present for up to 5 minutes after the input mains voltage is disconnected. Do not touch the unit during this time. The power supplies unit should be installed in minimum IP54 rated enclosure. The power supplies are built in units and must be installed in a cabinet or room (condensation free environment and indoor location) that is relatively free of conductive contaminants. All parameters are specified at 25°C ambient and AC input unless otherwise indicated. www.DeltaPSU.com (September 2021, Rev. 06) TECHNICAL DATASHEET CliQ DIN Rail Power Supply 24V 48W 1 Phase / DRP-24V48W1AZ Functions  Graph illustrating the Start-up Time, Rise Time, and Hold-up Time Start-up Time The time required for the output voltage to reach 90% of its final steady state set value, after the input voltage is applied. Rise Time The time required for the output voltage to change from 10% to 90% of its final steady state set value. Hold-up Time Time between the collapse of the AC input voltage, and the output falling to 95% of its steady state set value. Inrush Current Dynamic Response Inrush current is the peak, instantaneous, input current measured and, occurs when the input voltage is first applied. For AC input voltages, the maximum peak value of inrush current will occur during the first half cycle of the applied AC voltage. This peak value decreases exponentially during subsequent cycles of AC voltage. The power supply output voltage will remains within ±5% of its steady state value, when subjected to a dynamic load from 10% to 100% of its rated current. 10  50% duty cycle / 5 Hz to 1 KHz All parameters are specified at 25°C ambient and AC input unless otherwise indicated. www.DeltaPSU.com (September 2021, Rev. 06) TECHNICAL DATASHEET CliQ DIN Rail Power Supply 24V 48W 1 Phase / DRP-24V48W1AZ Overload & Overcurrent Protections (Auto-Recovery) Overvoltage Protection (Auto-Recovery) The power supply’s Overload (OLP) and Overcurrent (OCP) Protections will be activated when output current exceeds 105~180% of IO (Max load). In such occurrence, the VO will start to droop and once the power supply has reached its maximum power limit, the protection is activated and the power supply will go into “Hiccup mode” (Auto-Recovery). The power supply will recover once the fault condition of the OLP and OCP is removed and IO is back within the specifications. The power supply’s overvoltage circuit will be activated when its internal feedback circuit fails. The output voltage shall not exceed its specifications defined on Page 3 under “Protections”. Over Temperature Protection (Auto-Recovery) Additionally, if the IO is 100% for a prolong period of time (depending on the load), the Over Temperature Protection (OTP) will be activated due to high temperature on critical components. The power supply will then go into “Latch mode” until the PSU cools down and the AC power is recycled. As mentioned, the power supply also has Over Temperature Protection (OTP). This is activated when the overload condition persists for an extended duration and the output current is below the overload trigger point but >100% load. In the event of a higher operating condition at 100% load, the power supply will run into OTP when the surrounding air temperature is >75°C. When activated, the output voltage will go into latch-off mode until the component temperature cools down and the AC power is recycled. Short Circuit Protection (Auto-Recovery) The power supply’s output OLP/OCP function also provides protection against short circuits. When a short circuit is applied, the output current will operate in “Hiccup mode”, as shown in the illustration in the OLP/OCP section on this page. The power supply will return to normal operation after the short circuit is removed. External Input Protection Device The unit is protected at the L pin, with an internal fuse that cannot be replaced. The power supply has been tested and approved on 20 A (UL) and 16 A (IEC) branch circuits without additional protection device. An external protection device is only required if the supplying branch has an ampacity greater than above. Thus, if an external protective device is necessary, or, utilized, please refer a minimum value of 10 A B- or 6 A C- characteristic breaker. 11 All parameters are specified at 25°C ambient and AC input unless otherwise indicated. www.DeltaPSU.com (September 2021, Rev. 06) TECHNICAL DATASHEET CliQ DIN Rail Power Supply 24V 48W 1 Phase / DRP-24V48W1AZ Operating Mode  Redundant Operation In order to ensure proper redundant operation for the power supply unit (PSU), the output voltage difference between the two units must be kept at 0.45~0.50 V for 24 V supplies. Follow simple steps given below to set them up for the redundant operation: Step 1. Measure output voltage of PSU 1 and PSU 2. If PSU 1 is the master unit, then VO of PSU 1 must be higher than PSU 2. In order to set the output voltage, individually connect the power supply to 50% of rated load at any line voltage from 85-264 Vac, and set the PSU 1 and PSU 2 output voltage. Step 2. Connect the power supply units PSU 1 and PSU 2 to Vin 1 & Vin 2, respectively, of the DRR-20N (or 20A) module shown on the diagram on the right. Step 3. Connect the system load from Vout. Please note that output voltage Vout from DRR module will be = VO (output voltage of power supply) – Vdrop* (in DRR module). **The Signal GND in the DRR module is for the built-in LED and DC OK signals. The Output GND terminals from the two PSU’s do not need to be connected to the Signal GND terminal. Fig. 2 Redundant Operation Connection Diagram Fig. 3 Parallel Operation Connection Diagram *Vdrop will vary from 0.60V to 0.90V (Typical 0.65V) depending on the load current and surrounding air temperature.  Parallel Operation The power supply units (PSUs) can also be used for parallel operation in order to increase the output power. The difference in output voltage between the two units must be kept to within 25mV of each other. This difference must be verified with the same output load connected independently to each unit. Parameters such as EMI, inrush current, leakage current, PARD, start up time will be different from those on the datasheet, when two units are connected in parallel. The user will need to verify that any differences will still allow the two power supplies connected in parallel will work properly in their product/application. 12 All parameters are specified at 25°C ambient and AC input unless otherwise indicated. www.DeltaPSU.com (September 2021, Rev. 06) TECHNICAL DATASHEET CliQ DIN Rail Power Supply 24V 48W 1 Phase / DRP-24V48W1AZ Fig. 4  DC Input Operation Connection Diagram DC Input Operation Step 1. Use a battery or similar DC source. Step 2. Connect +pole to L and -pole to N. Step 3. Connect the PE terminal to an earth wire or to the machine ground. Fig. 5  2 of 3 Phase System Input Operation Connection Diagram 2 of 3 Phase System Input Operation Delta's CliQ can use on 2 of 3 phase system. Please refer to the following step. Step 1. The input voltage applied from Line to Neutral is below the maximum rated input. The input voltage shall be below 240 Vac +10%. Step 2. The external protector is needed on N (Neutral) input line to secure a safety. N line does not have internal fuse protection. An appropriate fuse or circuit breaker should be connected in series with N input line connection like the following. 13 All parameters are specified at 25°C ambient and AC input unless otherwise indicated. www.DeltaPSU.com (September 2021, Rev. 06) TECHNICAL DATASHEET CliQ DIN Rail Power Supply 24V 48W 1 Phase / DRP-24V48W1AZ Others Attention Delta provides all information in the datasheets on an “AS IS” basis and does not offer any kind of warranty through the information for using the product. In the event of any discrepancy between the information in the catalog and datasheets, the datasheets shall prevail (please refer to www.DeltaPSU.com for the latest datasheets information). Delta shall have no liability of indemnification for any claim or action arising from any error for the provided information in the datasheets. Customer shall take its responsibility for evaluation of using the product before placing an order with Delta. Delta reserves the right to make changes to the information described in the datasheets without notice. Manufacturer and Authorized Representatives Information Manufacturer Thailand Delta Electronics (Thailand) PCL. 909 Pattana 1 Rd., Muang, Samutprakarn, 10280 Thailand Taiwan Delta Electronics, Inc. 3 Tungyuan Road, Chungli Industrial Zone, Taoyuan County 32063, Taiwan Authorized Representatives The Netherlands Delta Greentech (Netherlands) B.V. Zandsteen 15, 2132 MZ Hoofddorp, The Netherlands 14 United Kingdom Delta Electronics Europe Limited 1 Redwood Court, Peel Park Campus, East Kilbride, Glasgow, G74 5PF, United Kingdom All parameters are specified at 25°C ambient and AC input unless otherwise indicated. www.DeltaPSU.com (September 2021, Rev. 06)
DRP-24V48W1AZ 价格&库存

很抱歉,暂时无法提供与“DRP-24V48W1AZ”相匹配的价格&库存,您可以联系我们找货

免费人工找货