DRP024V060W1NZ

DRP024V060W1NZ

  • 厂商:

    DELTA(台达)

  • 封装:

    -

  • 描述:

    AC/DC CONVERTER 24V 60W

  • 数据手册
  • 价格&库存
DRP024V060W1NZ 数据手册
TECHNICAL DATASHEET CliQ II DIN Rail Power Supply 24 V 60 W 1 Phase, NEC Class 2 / DRP024V060W1N□ Highlights & Features • • • • • • • • Universal AC input voltage range Power will not de-rate for the entire input voltage range UL 1310 safety approval NEC Class 2 and Limited Power Source (LPS) approvals Conforms to harmonic current IEC/EN 61000-3-2, Class A Conformal coating on PCBAs to protect against common dust and chemical pollutants Hazardous Locations approval for ATEX and Class I, Div 2 (DRP024V060W1NY) Certified according to IEC/EN/UL 62368-1 Safety Standards CB Certified for worldwide use Model Number: DRP024V060W1N☐ Unit Weight: 0.33 kg (0.73 lb) Dimensions (L x W x D): 120.6 x 32 x 119.3 mm (4.75 x 1.26 x 4.70 inch) General Description Delta’s CliQ II DIN rail power supply series with UL 1310 and NEC Class 2 approvals offers start-of-the-art designs made to withstand harsh industrial environments. The rugged plastic case is both shock and vibration resistant according to IEC 60068-2 and adheres to IP20 protection level. The products can be used in general industrial applications, especially for dry indoor condition with the advantage of lower wiring costs for a system due to its compliance with NEC Class 2 requirements. The NEC (National Electrical Code) is a North American standard, which is regarded as a law in most North American states. The NEC describes the installation of electric conductors and equipment within or on buildings. The Class 2 power units can operate over a wide temperature range of -25°C to +80°C (Cold Start at -40°C). The products also feature universal AC input voltage range from 85 Vac to 264 Vac and the power will not de-rate throughout the entire range. Another great feature is the conformal coating on the PCBA, which allows selected models to be certified to ATEX and Class I, Div 2 for use in hazardous locations. Model Information CliQ II DIN Rail Power Supply Model Number Input Voltage Range Rated Output Voltage Rated Output Current DRP024V060W1N☐ 85-264 Vac (120-375 Vdc) 24 Vdc 2.50 A Model Numbering DR P 024V DIN Rail Power Supply Output Voltage Output Power 1 060W 1 N □ Single Phase NEC Class 2 Y - Plastic Case, with Class I, Div 2 and ATEX Z - Plastic Case, without Class I, Div 2 and ATEX All parameters are specified at 25°C ambient and AC input unless otherwise indicated. www.DeltaPSU.com (June 2021, Rev. 08) TECHNICAL DATASHEET CliQ II DIN Rail Power Supply 24 V 60 W 1 Phase, NEC Class 2 / DRP024V060W1N□ Specifications Input Ratings / Characteristics Nominal Input Voltage 100-240 Vac Input Voltage Range 85-264 Vac Nominal Input Frequency 50-60 Hz Input Frequency Range 47-63 Hz DC Input Voltage Range* 120-375 Vdc Input Current < 1.50A @ 115 Vac, < 0.80A @ 230 Vac Efficiency at 100% Load > 89.0% @ 115 Vac & 230 Vac Max Power Dissipation 0% load 100% load < 0.4 W @ 115 Vac, < 0.9 W @ 230 Vac < 7.4 W @ 115 Vac & 230 Vac Max Inrush Current (Cold Start) < 40 A @ 115 Vac, < 80 A @ 230 Vac Leakage Current < 0.5 mA @ 240 Vac *Fulfills test conditions for this range. DC input safety approval can be obtained upon request. Output Ratings / Characteristics** Nominal Output Voltage 24 Vdc Factory Set Point Tolerance 24 Vdc ± 2% Output Voltage Adjustment Range 22-28 Vdc Output Current 2.50 A (60 W Max.) Output Power 60 W Line Regulation < 0.5% (@ 85-264 Vac input, 100% load) Load Regulation < 1.0% (@ 85-264 Vac input, 0-100% load) PARD*** (20 MHz) < 240 mVpp Rise Time < 100 ms @ nominal input (100% load) Start-up Time < 3,000 ms @ nominal input (100% load) Hold-up Time > 20 ms @ 115 Vac, > 125 ms @ 230 Vac (100% load) Dynamic Response (Overshoot & Undershoot O/P Voltage) ± 5% @ 85-264 Vac input, 0-100% load (Slew Rate: 0.1 A/μs, 50% duty cycle @ 5 Hz to 1 KHz) Start-up with Capacitive Loads 8,000 µF Max **For power de-rating from 50°C to 80°C, see power de-rating on page 3. ***PARD is measured with an AC coupling mode, 5 cm wires, and in parallel with 0.1 μF ceramic capacitor & 47 μF electrolytic capacitor. 2 All parameters are specified at 25°C ambient and AC input unless otherwise indicated. www.DeltaPSU.com (June 2021, Rev. 08) TECHNICAL DATASHEET CliQ II DIN Rail Power Supply 24 V 60 W 1 Phase, NEC Class 2 / DRP024V060W1N□ Mechanical Case Cover / Chassis Plastic Dimensions (L x W x D) 120.6 x 32 x 119.3 mm (4.75 x 1.26 x 4.70 inch) Unit Weight 0.33 kg (0.73 lb) Indicator Green LED Cooling System Terminal Wire DC OK Convection Input 3 Pins (Rated 300 V / 30 A) Output 2 Pins (Rated 300 V / 30 A) Input / Output AWG 20-10 Mounting Rail Standard TS35 DIN Rail in accordance with EN 60715 Noise (1 Meter from power supply) Sound Pressure Level (SPL) < 40 dBA Environment Surrounding Air Temperature Operating Storage Power De-rating -25°C to +80°C (Cold Start at -40°C) -40°C to +85°C Vertical Mounting > 50°C de-rate power by 2.5% / °C, > 70°C de-rate power by 4% / °C Horizontal Mounting > 50°C de-rate power by 2.5% / °C, > 70°C de-rate power by 4% / °C Operating Humidity 5 to 95% RH (Non-Condensing) Operating Altitude 0 to 2,500 Meters (8,200 ft.) Shock Test Non-Operating IEC 60068-2-27, 30 G (300 m/S²) for a duration of 18 ms, 1 time per direction, 2 times in total Vibration Non-Operating IEC 60068-2-6, 10 Hz to 500 Hz @ 30 m/S² (3 G peak); 60 min per axis for all X, Y, Z direction Bump Test Operating IEC 60068-2-29, Half Sine Wave: 10 G for a duration of 11 ms, 1,000 times per direction, 6,000 times in total Over Voltage Category III Pollution Degree 2 According to IEC/EN 62477-1 / EN 60204-1 (clearance and creepage distances) and IEC 62103 (safety part) Protections Overvoltage < 32V, ±10%, SELV Output, Hiccup Mode, Non-Latching (Auto-Recovery) Overload / Overcurrent > 110-150% of rated load current, Hiccup Mode, Non-Latching (Auto-Recovery) Over Temperature < 80°C Surrounding Air Temperature @ 100% load, Non-Latching (Auto-Recovery) Short Circuit Hiccup Mode, Non-Latching (Auto-Recovery when the fault is removed) Internal Fuse at L pin T 3.15 A H Degree of Protection IP20 Protection Against Shock Class I with PE* connection *PE: Primary Earth 3 All parameters are specified at 25°C ambient and AC input unless otherwise indicated. www.DeltaPSU.com (June 2021, Rev. 08) TECHNICAL DATASHEET CliQ II DIN Rail Power Supply 24 V 60 W 1 Phase, NEC Class 2 / DRP024V060W1N□ Reliability Data MTBF > 800,000 hrs. as per Telcordia SR-332 I/P: 115 Vac & 230 Vac, O/P: 100% load, Ta: 25°C Expected Cap Life Time 10 years (115 Vac & 230 Vac, 50% load @ 40°C) Safety Standards / Directives Electrical Equipment of Machines EN/BS EN 60204-1 (over voltage category III) Electrical Equipment for use in Electrical Power Installations IEC/EN/BS 62477-1 / IEC 62103 Safety Entry Low Voltage SELV (IEC 60950-1) Electrical Safety SIQ Bauart UL/cUL recognized CB Scheme UKCA Industrial Control Equipment UL/cUL listed CSA Hazardous Location / ATEX (For DRP024V060W1NY) cCSAus ATEX Class 2 Power Supply UL/cUL recognized CE UL 60950-1 and CSA C22.2 No. 60950-1 (File No. E191395) UL 62368-1 and CSA C22.2 No. 62368-1 (File No. E191395) IEC 60950-1, IEC 62368-1, Limited Power Source (LPS) BS EN 62368-1 UL 508 and CSA C22.2 No. 107.1-01 (File No. E315355) CSA C22.2 No. 107.1-01 (File No. 181564) CSA C22.2 No. 213-M1987, ANSI / ISA 12.12.01:2007 [Class I, Division 2, Group A, B, C, D T4, Ta= -25°C to +80°C (> +50°C derating)] EN 60079-0:2009, EN 60079-15:2010 [ II 3G Ex nA nC IIC T4 Gc, Ta= -25°C to +80°C (> +50°C derating)] Certificate No. EPS 12 ATEX 1 491 X UL 1310 and CSA C22.2 No. 223 (File No. E350883) In conformance with EMC Directive 2014/30/EU and Low Voltage Directive 2014/35/EU UKCA Galvanic Isolation 4 EN 62368-1 Input to Output For DRP024V060W1NY: In conformance with Equipment for explosive atmospheres (ATEX) directive 2014/34/EU In conformance with Electrical Equipment (Safety) Regulations 2016 No. 1011 and The Electromagnetic Compatibility Regulations 2016 No. 1091 4.0 KVac Input to Ground 1.5 KVac Output to Ground 1.5 KVac All parameters are specified at 25°C ambient and AC input unless otherwise indicated. www.DeltaPSU.com (June 2021, Rev. 08) TECHNICAL DATASHEET CliQ II DIN Rail Power Supply 24 V 60 W 1 Phase, NEC Class 2 / DRP024V060W1N□ EMC Emissions (CE & RE) Generic Standards: CISPR 32, EN/BS EN 55032, CISPR 11, EN/BS EN 55011, FCC Title 47: Class B Component Power Supply for General Use EN/BS EN 61204-3 Immunity Generic Standards: EN/BS EN 55024, EN/BS EN 61000-6-2 Electrostatic Discharge IEC 61000-4-2 Level 4 Criteria A1) Air Discharge: 15 kV Contact Discharge: 8 kV Radiated Field IEC 61000-4-3 Level 3 Criteria A1) 80 MHz-1 GHz, 10 V/M, 80% modulation (1 kHz) Electrical Fast Transient / Burst IEC 61000-4-4 Level 3 Criteria A1) 2 kV Surge IEC 61000-4-5 Level 3 Criteria A1) Common Mode2): 2 kV Differential Mode3): 2 kV Conducted IEC 61000-4-6 Level 3 Criteria A1) 150 kHz-80 MHz, 10 Vrms Power Frequency Magnetic Fields IEC 61000-4-8 Criteria A1) 10 A/Meter Voltage Dips and Interruptions IEC 61000-4-11 100% dip; 1 cycle (20 ms); Self Recoverable Low Energy Pulse Test (Ring Wave) IEC 61000-4-12 Harmonic Current Emission Level 3 Criteria A1) Common Mode2): 2 kV Differential Mode3): 1 kV IEC/EN/BS EN 61000-3-2, Class A Voltage Fluctuation and Flicker IEC/EN/BS EN 61000-3-3 1) Criteria A: Normal performance within the specification limits 2) Asymmetrical: Common mode (Line to earth) 3) Symmetrical: Differential mode (Line to line) 5 All parameters are specified at 25°C ambient and AC input unless otherwise indicated. www.DeltaPSU.com (June 2021, Rev. 08) TECHNICAL DATASHEET CliQ II DIN Rail Power Supply 24 V 60 W 1 Phase, NEC Class 2 / DRP024V060W1N□ Block Diagram 6 All parameters are specified at 25°C ambient and AC input unless otherwise indicated. www.DeltaPSU.com (June 2021, Rev. 08) TECHNICAL DATASHEET CliQ II DIN Rail Power Supply 24 V 60 W 1 Phase, NEC Class 2 / DRP024V060W1N□ Device Description 1) 2) 3) 4) 5) Input terminal block connector Output terminal block connector DC Voltage adjustment potentiometer DC OK control LED (Green) Universal mounting rail system Dimensions L x W x D: 120.6 x 32 x 119.3 mm (4.75 x 1.26 x 4.70 inch) 7 All parameters are specified at 25°C ambient and AC input unless otherwise indicated. www.DeltaPSU.com (June 2021, Rev. 08) TECHNICAL DATASHEET CliQ II DIN Rail Power Supply 24 V 60 W 1 Phase, NEC Class 2 / DRP024V060W1N□ Engineering Data Output Load De-rating VS Surrounding Air Temperature Note 1. 2. 3. Fig. 1 De-rating for Vertical and Horizontal Mounting Orientation > 50°C de-rate power by 2.5% / °C, > 70°C de-rate power by 4% / °C 4. 5. Power supply components may degrade, or be damaged, when the power supply is continuously used outside the shaded region, refer to the graph shown in Fig. 1. If the output capacity is not reduced when surrounding air temperature exceeds its specification as defined on Page 3 under “Environment”, the device will run into Over Temperature Protection. When activated, the output voltage will go into bouncing mode and will recover when the surrounding air temperature is lowered or the load is reduced as far as necessary to keep the device in working condition. In order for the device to function in the manner intended, it is also necessary to keep a safety distance as recommended in the safety instructions while the device is in operation. Depending on the surrounding air temperature and output load delivered by the power supply, the device can be very hot! If the device has to be mounted in any other orientation, please contact info@deltapsu.com for more details. Output Load De-rating VS Input Voltage  8 No output power de-rating across the entire input voltage range All parameters are specified at 25°C ambient and AC input unless otherwise indicated. www.DeltaPSU.com (June 2021, Rev. 08) TECHNICAL DATASHEET CliQ II DIN Rail Power Supply 24 V 60 W 1 Phase, NEC Class 2 / DRP024V060W1N□ Assembly & Installation The power supply unit (PSU) can be mounted on 35 mm DIN rails in accordance with EN 60715. The device should be installed with input terminal block at the bottom. Each device is delivered ready to install. Mounting Dismounting Fig. 2.1 Mounting Fig. 2.2 Dismounting Snap on the DIN rail as shown in Fig. 2.1: 1. Tilt the unit upwards and insert it onto the DIN rail. 2. Push downwards until stopped. 3. Press against the bottom front side for locking. 4. Shake the unit slightly to ensure that it is secured. To uninstall, pull or slide down the latch with screw driver as shown in Fig. 2.2. Then slide the power supply unit (PSU) in the opposite direction, release the latch and pull out the power supply unit (PSU) from the rail. In accordance to EN 60950 / UL 60950 and EN 62368 / UL 62368, flexible cables require ferrules. Use appropriate copper cables designed to sustain operating temperature of: 1. 60°C, 60°C / 75°C for USA 2. At least 75°C for ambient not exceeding 60°C, and 90°C for ambient exceeding 60°C for Canada. 9 All parameters are specified at 25°C ambient and AC input unless otherwise indicated. www.DeltaPSU.com (June 2021, Rev. 08) TECHNICAL DATASHEET CliQ II DIN Rail Power Supply 24 V 60 W 1 Phase, NEC Class 2 / DRP024V060W1N□ Safety Instructions Horizontal Mounting  Vertical Mounting • ALWAYS switch mains of input power OFF before connecting and disconnecting the input voltage to the unit. If mains are not turned OFF, there is risk of explosion / severe damage. To guarantee sufficient convection cooling, keep a distance of 50 mm (1.97 inch) above and below the device as well as a lateral distance of 20 mm (0.79 inch) to other units. Note that the enclosure of the device can become very hot depending on the surrounding air temperature and load of the power supply. Risk of burns! Only plug in and unplug connectors when power is turned off! DO NOT insert any objects into the unit. Hazardous voltages may be present for up to 5 minutes after the input mains voltage is disconnected. Do not touch the unit during this time. The power supplies are built in units and must be installed in a cabinet or room (condensation free environment and indoor location) that is relatively free of conductive contaminants. CAUTION: “For use in a controlled environment”. • • • • • • •  For DRP024V060W1NY: • The power supplies unit must be installed in an IP54 enclosure or cabinet in the final installation. The enclosure or cabinet must comply with EN 60079-0 or EN 60079-15. • Warning: Explosion Hazard - Substitution of components may impair suitability for Class I, Division 2. • Warning: Explosion Hazard - Do not disconnect equipment or adjust potentiometer unless the power has been switched off or the area is known to be non-hazardous. 10 All parameters are specified at 25°C ambient and AC input unless otherwise indicated. www.DeltaPSU.com (June 2021, Rev. 08) TECHNICAL DATASHEET CliQ II DIN Rail Power Supply 24 V 60 W 1 Phase, NEC Class 2 / DRP024V060W1N□ Functions  Graph illustrating the Start-up Time, Rise Time, and Hold-up Time Start-up Time The time required for the output voltage to reach 90% of its final steady state set value, after the input voltage is applied. Rise Time The time required for the output voltage to change from 10% to 90% of its final steady state set value. Hold-up Time Time between the collapse of the AC input voltage, and the output falling to 95% of its steady state set value. Inrush Current Dynamic Response Inrush current is the peak, instantaneous, input current measured and, occurs when the input voltage is first applied. For AC input voltages, the maximum peak value of inrush current will occur during the first half cycle of the applied AC voltage. This peak value decreases exponentially during subsequent cycles of AC voltage. The power supply output voltage will remains within ±5% of its steady state value, when subjected to a dynamic load from 0 to 100% of its rated current.  50% duty cycle / 5Hz to 1KHz External Input Protection Device The unit is protected at the L pin, with an internal fuse that cannot be replaced. The power supply has been tested and approved on 20 A (UL) and 16 A (IEC) branch circuits without additional protection device. An external protection device is only required if the supplying branch has an ampacity greater than above. Thus, if an external protective device is necessary, or, utilized, please refer a minimum value of 16 A B- or 8 A C- characteristic breaker. 11 All parameters are specified at 25°C ambient and AC input unless otherwise indicated. www.DeltaPSU.com (June 2021, Rev. 08) TECHNICAL DATASHEET CliQ II DIN Rail Power Supply 24 V 60 W 1 Phase, NEC Class 2 / DRP024V060W1N□ Overload & Overcurrent Protections (Auto-Recovery) Overvoltage Protection (Auto-Recovery) The power supply’s Overload (OLP) and Overcurrent (OCP) Protections will be activated when output current (IO) exceeds its specification as defined on Page 3 under “Protections”. In such occurrence, the output voltage (VO) will start to droop and once the power supply has reached its maximum power limit, the protection is activated and the power supply will go into “Hiccup mode” (AutoRecovery). The power supply will recover once the fault condition of the OLP and OCP is removed and IO is back within the specifications. The power supply’s overvoltage circuit will be activated when its internal feedback circuit fails. The output voltage shall not exceed its specifications defined on Page 3 under “Protections”. Over Temperature Protection (Auto-Recovery) It is not recommended to prolong the duration of IO when it is less than OLP/OCP point, but greater than 100%, since it may cause damage to the PSU. As described in load de-rating section, the power supply also has Over Temperature Protection (OTP). In the event of a higher operating temperature at 100% load, the power supply will run into OTP when the operating temperature is beyond what is recommended in the de-rating graph. When activated, the output voltage will go into bouncing mode until the temperature drops to its normal operating temperature as recommended in the de-rating graph. Short Circuit Protection (Auto-Recovery) The power supply’s output OLP/OCP function also provides protection against short circuits. When a short circuit is applied, the output current will operate in “Hiccup mode”, as shown in the illustration in the OLP/OCP section on this page. The power supply will return to normal operation after the short circuit is removed. 12 All parameters are specified at 25°C ambient and AC input unless otherwise indicated. www.DeltaPSU.com (June 2021, Rev. 08) TECHNICAL DATASHEET CliQ II DIN Rail Power Supply 24 V 60 W 1 Phase, NEC Class 2 / DRP024V060W1N□ Operating Mode  Redundant Operation In order to ensure proper redundant operation for the power supply unit (PSU), the output voltage difference between the two units must be kept at 0.45~0.50 V for 24 V supplies. Follow simple steps given below to set them up for the redundant operation: Step 1. Measure output voltage of PSU 1 and PSU 2. If PSU 1 is the master unit, then VO of PSU 1 must be higher than PSU 2. In order to set the output voltage, individually connect the power supply to 50% of rated load at any line voltage from 85264 Vac, and set the PSU 1 and PSU 2 output voltage. Step 2. Connect the power supply units PSU 1 and PSU 2 to Vin 1 & Vin 2, respectively, of the DRR-20N (or 20 A) module shown on the diagram on the right. Step 3. Connect the system load from Vout. Please note that output voltage Vout from DRR module will be = VO (output voltage of power supply) – Vdrop* (in DRR module). **The Signal GND in the DRR module is for the built-in LED and DC OK signals. The Output GND terminals from the two PSU’s do not need to be connected to the Signal GND terminal. Fig. 3 Redundant Operation Connection Diagram Fig. 4 Parallel Operation Connection Diagram *Vdrop will vary from 0.60 V to 0.90 V (Typical 0.65 V) depending on the load current and surrounding air temperature.  Parallel Operation The power supply units (PSUs) can also be used for parallel operation in order to increase the output power. The difference in output voltage between the two units must be kept to within 25 mV of each other. This difference must be verified with the same output load connected independently to each unit. Parameters such as EMI, inrush current, leakage current, PARD, start up time will be different from those on the datasheet, when two units are connected in parallel. The user will need to verify that any differences will still allow the two power supplies connected in parallel will work properly in their product/application. 13 All parameters are specified at 25°C ambient and AC input unless otherwise indicated. www.DeltaPSU.com (June 2021, Rev. 08) TECHNICAL DATASHEET CliQ II DIN Rail Power Supply 24 V 60 W 1 Phase, NEC Class 2 / DRP024V060W1N□ Fig. 5  DC Input Operation Connection Diagram DC Input Operation Step 1. Use a battery or similar DC source. Step 2. Connect +pole to L and -pole to N. Step 3. Connect the PE terminal to an earth wire or to the machine ground. Fig. 6  2 of 3 Phase System Input Operation Connection Diagram 2 of 3 Phase System Input Operation Delta's CliQ II can use on 2 of 3 phase system. Please refer to the following step. Step 1. The input voltage applied from Line to Neutral is below the maximum rated input. The input voltage shall be below 240 Vac +10%. Step 2. The external protector is needed on N (Neutral) input line to secure a safety. N line does not have internal fuse protection. An appropriate fuse or circuit breaker should be connected in series with N input line connection like the following. 14 All parameters are specified at 25°C ambient and AC input unless otherwise indicated. www.DeltaPSU.com (June 2021, Rev. 08) TECHNICAL DATASHEET CliQ II DIN Rail Power Supply 24 V 60 W 1 Phase, NEC Class 2 / DRP024V060W1N□ Others Conformal Coating The Protective Coating Technology Delta Electronics Group has designed the perfect dipping technique which penetrates everywhere including under device, and prevents leakage. The conformal coating dipping can be applied to PCBAs or circuit board. The coating preserves the performance of precision electronic primarily by preventing ionizable contaminants such as salt from reaching circuit nodes, where the material slumps around sharp edges. This can be a problem especially in highly conversing atmosphere. Attention Delta provides all information in the datasheets on an “AS IS” basis and does not offer any kind of warranty through the information for using the product. In the event of any discrepancy between the information in the catalog and datasheets, the datasheets shall prevail (please refer to www.DeltaPSU.com for the latest datasheets information). Delta shall have no liability of indemnification for any claim or action arising from any error for the provided information in the datasheets. Customer shall take its responsibility for evaluation of using the product before placing an order with Delta. Delta reserves the right to make changes to the information described in the datasheets without notice. Manufacturer and Authorized Representatives Information Manufacturer Thailand Delta Electronics (Thailand) PCL. 909 Pattana 1 Rd., Muang, Samutprakarn, 10280 Thailand Taiwan Delta Electronics, Inc. 3 Tungyuan Road, Chungli Industrial Zone, Taoyuan County 32063, Taiwan Authorized Representatives The Netherlands Delta Greentech (Netherlands) B.V. Zandsteen 15, 2132 MZ Hoofddorp, The Netherlands 15 United Kingdom Delta Electronics Europe Limited 1 Redwood Court, Peel Park Campus, East Kilbride, Glasgow, G74 5PF, United Kingdom All parameters are specified at 25°C ambient and AC input unless otherwise indicated. www.DeltaPSU.com (June 2021, Rev. 08)
DRP024V060W1NZ 价格&库存

很抱歉,暂时无法提供与“DRP024V060W1NZ”相匹配的价格&库存,您可以联系我们找货

免费人工找货
DRP024V060W1NZ
    •  国内价格 香港价格
    • 1+374.962371+46.52376
    • 24+345.3316224+42.84730
    • 48+325.5992948+40.39900
    • 72+315.7328472+39.17481
    • 120+295.99994120+36.72643
    • 264+271.33336264+33.66591

    库存:409