Model Name: FHS-A6025B00
DELTA ELECTRONICS, INC.
Application:
• Intel Nehalem Socket 1366 2U
• Xeon (45nm) E5500/L5500
CPU sequence
Pictures
Thermal & Mechanical Spec.:
• Thermal performance for 80W CPU
• HSK Assembly Weight: 500 g (ref.)
• Clipping Force: 16 Kgf (ref.)
θca (℃/W)
1. Heat Sink
Type: Extrude HSK
Material: Aluminum A6063 or Equivalent.
Dimension: 90*90*64 mm
2. Thermal interface material 2
Material: Dow Corning TC-5630 or Equivalent.
3. Fan
Thermal Performance Curve
(60x60x25 mm with PWM Control)
0.38
60.00
Rated Voltage: 12 V
0.36
55.00
Life Time:
0.34
50.00
Two ball bearing 80000 hrs
Connector:
0.32
45.00
a. Lead wire: UL 1061 AWG#26
0.30
40.00
pin 1: black wire--------(-)
0.28
35.00
pin 2: yellow wire----------(+)
3000
4000
5000
6000
7000
THERMAL RESISTANCE
pin 3: green wire---------(F00)
Speed (rpm)
Noise
pin 4: blue wire------------(PWM)
* All readings are typical values at rated voltage.
b. Housing: Molex 47054-1000 or equivalent
c. Terminal: Molex 2759T 08-50-0113 or equivalent
Noise (dBA)
Component Specification:
* Specifications are subject to change without notice
DELTA ELECTRONICS, INC.
252, Shang Ying Road, Kuei San
TAOYUAN SHIEN 333,
TAIWAN,R.O.C.
TEL: 886-3-3591968 EXT 2073
FAX: 886-3-3591991
DELTA PRODUCTS CORPORATION
4405 CUSHING PARKWAY
FREMONT, CA 94538, U.S.A.
TEL: 1-510-668-5100
FAX: 1-510-668-0680
DELTA ELECTRONICS(JAPAN), INC.
DELTA SHIBADAIMON BLDG.
2-1-14 SHIBADAIMON, MINATO-KU,
TOKYO, 105-0012, JAPAN
TEL: 81-3-5733-1111
FAX: 81-3-5733-1211
DELTA ELECTRONICS EUROPE LTD.
2 YOUNG PLACE
KELVIN INDUSTRIAL ESTATE
EAST KILBRIDE, GLASGOW G75 OTD, U.K.
TEL: 44-1355-588888
FAX: 44-1355-588889
Date: 27-Apr-07
Delta Electronics Corp.
APPROVAL SHEET
Customer Name .:
Model Name.:
COOLER
Delta Part No.:
FHS-A6025B00
Customer Part No.:
Spec Issue Date .:
Spec Revision :
12/31/2015
02
PLEASE SEND ONE COPY OF THIS SPECIFICATION BACK AFTER YOU
SIGNED APPROVAL FOR PRODUCTION PRE-ARRANGMENT.
Approved By:
Date:
Approval
Form No.︰tMP—D029
Check
Designer
Form Rev.︰00
Delta Electronics Corp.
REV.
Description
Drawn
00
ISSUE SPEC
Skyler-Huang01/05’10
01
1. CHANGE THE FAN P/N FROM
3620927211 TO 3620936511
2. CHANGE THE FAN LABEL
P/N FROM 3266498200 TO
3266800400
3. CORRECT THE FAN LABEL
Checked
01/05’10
Approved
Issue
Date
01/05’10
Skyler-Huang07/24’13
07/24’13
07/24’13
12/31’15
12/31’15
12/31’15
MATERIAL&CARTON SIZE
4. CHANGE SCREW
P/N FROM 3105464700 TO
3534205600
02
Change TIM from TC-1996 to
TC-5630
Description:
SAMPLE REVISION CODE LIST
Part No.
REV
DELTA MODEL :
FHS-A6025B00
Form No.︰tMP—D029
TOTAL 24 PAGE
02
Form Rev.︰00
Delta Electronics Corp.
CONTENTS
Item
Element Description
Page
1
Specification
5
2
Print
6
3
Packing Plan
12
4
Fan
15
Form No.︰tMP—D029
Note
Form Rev.︰00
Delta Electronics Corp.
1. SPECIFICATION
Characters
Item
Scope
Description
THIS SPECIFICATION DEFINES THE ELECTRICAL AND
MECHANICAL CHARACTERISTICS OF THE FAN HEATSINK
INTEL CPU COOLER
Application
Specification
a: Thermal Resistance 0.306 (℃/W) (REF.)
500 g (REF.)
b: total weight
16 kgf (REF.)
c: clip force
BOM
Item
Part Name
1
FAN
2
HEATSINK
3
Material
Part NO.
Q’TY
PBT
3620936511
1
AL6063
3346423400
1
FAN SCREW
SUS
3109183100
2
4
SCREW
SUS
3534205600
4
5
LABEL
PP OR PET
3266800400
1
6
TIM
DOW TC-5630
4021107300
0.2g
7
SPRING
SWPA
3461809700
4
8
E-CLIP
S20C
3110262800
4
9
CAP
SUS303
3462384700
4
Form No.︰tMP—D029
Remark
Rev02
Form Rev.︰00
Delta Electronics Corp.
2. PRINT
Assembly Drawing
Parts Drawing
Form No.︰tMP—D029
Form Rev.︰00
Delta Electronics Corp.
3. PACKING PLAN
Packing Specification
Form No.︰tMP—D029
Form Rev.︰00
Delta Electronics Corp.
4. FAN
Fan Specification
Form No.︰tMP—D029
Form Rev.︰00
SPECIFICATION FOR APPROVAL
Customer
_TMPBU____
Description
DC FAN
Part No.
__
3620936511
REV.
______
Delta Model No. __AFB0612DH-BC01 __ REV. _ 01
Sample Issue No.
Sample Issue Date _AUG.13.2012
PLEASE SEND ONE COPY OF THIS SPECIFICAITON BACK
AFTER YOU SIGNED APPROVAL FOR PRODUCTION PREARRANGMENT.
APPROVED BY:
DATE
:
DELTA ELECTRONICS, INC.
TAOYUAN PLANT
252, SHANG YING ROAD, KUEI SAN INDUSTRIAL ZONE TAOYUAN
SHIEN, TAIWAN, R.O.C.
TEL:886-(0)3-3591968
FAX:886-(0)3-3591991
Application Notice
1. Delta will not guarantee the performance of the products if the application condition
falls outside the parameters set forth in the specification.
2. A written request should be submitted to Delta prior to approval if deviation from
this specification is required.
3. Please exercise caution when handling fans. Damage may be caused when pressure is
applied to the impeller, if the fans are handled by the lead wires, or if the fan was
hard-dropped to the production floor.
4. Except as pertains to some special designs, there is no guarantee that the products will
be free from any such safety problems or failures as caused by the introduction of
powder, droplets of water or encroachment of insect into the hub.
5. The above-mentioned conditions are representative of some unique examples and viewed
as the first point of reference prior to all other information.
6. It is very important to establish the correct polarity before connecting the fan to the
power source. Positive (+) and Negative (-). Damage may be caused to the fans if
connection is with reverse polarity, if there is no foolproof method to protect against
such error specifically mentioned in this spec.
7. Delta fans without special protection are not suitable where any corrosive fluids are
introduced to their environment.
8. Please ensure all fans are stored according to the storage temperature limits specified.
Do not store fans in a high humidity environment. We highly recommend performance
testing is conducted before shipping, if the fans have been stored over 6 months.
9. Not all fans are provided with the Lock Rotor Protection feature. If you impair the
rotation of the impeller for the fans that do not have this function, the performance
of those fans will lead to failure.
10. Please be cautious when mounting the fan. Incorrect mounting of fans may cause
excess resonance, vibration and subsequent noise.
11. It is important to consider safety when testing the fans. A suitable fan guard should be
fitted to the fan to guard against any potential for personal injury.
12. Except where specifically stated, all tests are carried out at room (ambient) temperature
and relative humidity conditions of 25oC, 65% RH. The test value is only for fan
performance itself.
13. Be certain to connect an “ 4.7µF or greater” capacitor to the fan externally when
the application calls for using multiple fans in parallel, to avoid any unstable power.
Doc. No: FMBG-ES Form 001 Rev. 0001
Date: June 24, 2009
很抱歉,暂时无法提供与“FHS-A6025B00”相匹配的价格&库存,您可以联系我们找货