Specification For Approval
Customer :
Description :
Thermal Electric Cooling 200W
Customer part no :
Delta model no :
Sample issue no :
Sample issue date :
Rev. :
Rev. :
HET200PB
03
JUN .21.2013
Modify history
Rev.
Description
Drawn
Approved
Issue Date
Nick Wang
Diamond Chen
2012/1/18
Ted.Tu
Diamond Chen
2012/12/12
00
ISSUE SPEC
01
Adding 2-4 & 6
02
Modify the noise.
Nick Wang
Diamond Chen
2013/4/16
03
Add the safety trademark
Nick Wang
Diamond Chen
2013/06/21
Please send one copy of this specification back after you
signed approval for production pre-arrangement
Approved by :
Date :
DELTA ELECTRONICS, INC.
252, SHANG YING ROAD, KUEI SAN
TAOYUAN HSIEN 333, TAIWAN, R. O. C.
Page 1
TEL : 886-(0)3-3591968
FAX : 886-(0)3-3591991
*** SAMPLE HISTORY***
CUSTOMER:
CUSTOMER P/N:
DELTA MODEL : HET200PB
REV.
DESCRIPTION
DRAWN
CHECKED
ME
EE
汪則鑫 1/18'12 涂雅森 1/18'12
CE
------
APPROVED
00 ISSUE SPEC
汪則鑫 1/18'12
01 Adding 2-4 & 6.
涂雅森 12/12'12 汪則鑫 12/12'12 涂雅森 12/12'12 ------ 陳李龍 12/12'12 12/12'12
02 Modify the noise
03 Add the safety trademark.
汪則鑫 4/16'13
汪則鑫 6/21'13
汪則鑫 4/16'13
汪則鑫 6/21'13
PAGE 1 OF 1
涂雅森 4/16'13
涂雅森 6/21'13
陳李龍 1/18'12
ISSUE
DATE
1/18'12
------ 陳李龍 4/16'13
------ 陳李龍 6/21'13
4/16'13
6/21'13
History-000
Table of content
1. Description --------------------------------------------------------------------------------- 4
1-1. General description --------------------------------------------------------------- 4
1-2.
1-3.
1-4.
1-5.
Main feature & model number --------------------------------------------------4
Dimension --------------------------------------------------------------------------- 5
Maintenance ------------------------------------------------------------------------ 7
Thermal path & Airflow baffle --------------------------------------------------- 8
2. Electrical specification ------------------------------------------------------------------ 9
2-1. Indicator & connector ------------------------------------------------------------- 9
2-2. Cooling Performance VS Temperature Difference ------------------------- 9
2-3. TEC work temperature range---------------------------------------------------- 9
2-4. Interface------------------------------------------------------------------------------- 10
3. Environmental condition --------------------------------------------------------------- 11
3-1. Operating temperature ----------------------------------------------------------- 11
3-2. Storage temperature -------------------------------------------------------------- 11
3-3. Humidity ------------------------------------------------------------------------------ 11
3-4. Protection rating -------------------------------------------------------------------- 11
3-5. MTBF---------------------------------------------------------------------------------- 11
4. Certified safety --------------------------------------------------------------------------- 12
4-1. UL , CUL, TUV, CE
5. User cable------ --------------------------------------------------------------------------- 12
5-1. Power cable
5-2. Alarm cable
Page 2
Specification for approval
Customer :
Description : Thermal Electric Cooling 200W
Customer P/N :
Rev. :
Delta model no. : HET200PB
Rev. : 03
Sample revision :
Issue no. :
Sample issue date :
Quantity :
Page 3
sets
Part no. :
Delta model no. : HET200PB
1. Description
1-1. General description :
The Thermal Electric Cooling (TEC) is designed for direct air to air heat
removal in the cabinet. It is easy to be installed in the cabinet
(recommended on the door of the cabinet) with the nuts.
The internal and external air circulation loops of the TEC Module are
separated to prevent the entry of dust, humidity and dirt. The unit conforms
to IP55 protection rating on the external air circuit.
1-2. Main feature (Operating 48VDC at 25 ゚ C)
Model Number
Main feature
Unit
HET200PB
Outline dimension
mm
400 H x 180 W x 208 D
Weight
Kg
9.0 ± 0.5
Cooling capacity (△
△T =0 ℃)
W
200
Heating capacity @-40 ゚ C
W
225
Rated voltage
VDC
48 (TYP.)
Operating voltage range
VDC
40~56
Rated Current
A
6.7 (TYP.)
Rated Consumption
W
321.6
Operating temperature
°C
-40~55
Internal airflow rate
100 (TYP.)
cfm
External airflow rate
120 (TYP.)
Acoustic noise at 1M :
dB-A
61.0 dB-A(Typ.)
(Sound pressure)
Co o l in g a nd he a ti n g c apac it y i s f or in te r n a l s i de .
Page 4
64.0(Max.)
Part no. :
Delta model no. : HET200PB
1-3. Dimension
1-3-1 Drawing
(1) Material : case aluminum sheet , t=1.5mm
(2) Finish : Power paint 75~120um,
(3) Color : RAL 7032
(4) Dimension tolerance:
X.X [X.XX] : ± 1.0mm [0.04”]
X.XX [X.XXX] : ± 0.3mm [0.012”]
Page 5
Part no. :
Delta model no. : HET200PB
1-3-2 Mounting panel cutout
:
:
:
Page 6
Part no. :
Delta model no. : HET200PB
1-4. Maintenance
1-4-1. Be sure to disconnect power supply before disassembly TEC
module from customer cabinet.
1-4-2. Please refer to Delta authorized engineers for TEC module
component replacement service, no allow unauthorized personnel
to repair the unit.
1-4-3. If the replacement by user himself is necessary, please refer to the
exploded drawing shown as previous page and below description
for disassembly.
External fan: Disassemble mounting screw of external fan via screw
driver & pull out the connector.
Internal fan: Disassemble mounting screw of internal fan via screw
Driver & pull out the connector.
Controller: Need to disassemble internal fan first , then pull-out all
cable connection on controller , take off mounting screw
of controller finally .
TEC device: Due to TEC device have waterproof sealant protection
and thermal conductive compound with heat-sink, please
kindly ship back to Delta for replacement.
Page 7
Part no. :
Delta model no. : HET200PB
1-5. Thermal path and airflow baffle
The thermal exchange path is shown in the figure below.
Page 8
Part no. :
Delta model no. : HET200PB
2. Electrical specification
2-1. Indicator & connector
Connector " -48V VDC " mate with JWT C4201WR0-2*3PNL
2-2. Cooling Performance VS Temperature Difference
2-3. TEC work temperature range
HET200PB has two work status, cooling and heating, according to
the cabinet internal temperature (detect by on-board NTC).
Page 9
Part no. :
Delta model no. : HET200PB
2-4. Interface
LED "FAN"
(Green) : Fan normal
(Red) : Fan failed
(Blink Green) : Fan normal in test process
(Blink Red) : Fan failed in test process
LED "TEC" *
(Green) : TEC normal
(Red) : TEC failed
(Blink green) : TEC normal in test process
(Blink red) : TEC failed in test process or sensor failed
LED "STATUS"
(Green) : HET200PB work in cooling mode
(Red) : HET200PB work in heating mode
(Dark): HET200PB TEC function OFF
CLEAN/TEST
There is a auto test button on HET200PB, user can press this button to run
HET200PB heating and cooling process, the process is about 7~8 mints. User can
turn off this function by pressing this button again.
*:HET200PB will detect internal fan income air temperature and sink surface
temperature, It will compare two temperature to determine TEC is normal or
not.
Page 10
Part no. :
Delta model no. : HET200PB
Alarm dry contact:
Pin to pin “Open”:
Normal
Pin to pin “Close”:
Fan , TEC or sensor failed
Connector "Alarm"
Pin to Pin ----- MAX. ( ± 75VDC ) 50mA
3. Environmental conditions
3-1. Operating temperature :
-40°C ~ +55°C ( 14°F ~ 149°F)
3-2. Storage temperature :
-40°C ~ +65°C (-40°F ~ 149°F)
3-3. Humidity
External air circuit: 0 ~ 100% RH
Internal air circuit: 0 ~ 90% RH, Non-condensing
3-4. Protection rating
IP55 (IEC60529) on external side with mounting on door.
3-5. MTBF
Fan lifetime is expected to have a minimum L10 life of 80,000 hours
continuous operation at 40°C with 15 ~ 65%RH at 48 voltage
Page 11
Part no. :
Delta model no. : HET200PB
4. Certified safety
4-1. UL , CUL, TUV, CE
5. User cable
Each HET200PB will provide 2 cables with shipment.
5-1 Power cable
5-2 Alarm cable
Page 12
Application Notice
1. Delta will not guarantee the performance of the products if the application condition
falls outside the parameters set forth in the specification.
2. A written request should be submitted to Delta prior to approval if deviation from
this specification is required.
3. Please exercise caution when handling fans. Damage may be caused when pressure is
applied to the impeller, if the fans are handled by the lead wires, or if the fan was
hard-dropped to the production floor.
4. Except as pertains to some special designs, there is no guarantee that the products will
be free from any such safety problems or failures as caused by the introduction of
powder, droplets of water or encroachment of insect into the hub.
5. The above-mentioned conditions are representative of some unique examples and viewed
as the first point of reference prior to all other information.
6. It is very important to establish the correct polarity before connecting the fan to the
power source. Positive (+) and Negative (-). Damage may be caused to the fans if
connection is with reverse polarity, if there is no foolproof method to protect against
such error specifically mentioned in this spec.
7. Delta fans without special protection are not suitable where any corrosive fluids are
introduced to their environment.
8. Please ensure all fans are stored according to the storage temperature limits specified.
Do not store fans in a high humidity environment. We highly recommend performance
testing is conducted before shipping, if the fans have been stored over 6 months.
9. Not all fans are provided with the Lock Rotor Protection feature. If you impair the
rotation of the impeller for the fans that do not have this function, the performance
of those fans will lead to failure.
10. Please be cautious when mounting the fan. Incorrect mounting of fans may cause
excess resonance, vibration and subsequent noise.
11. It is important to consider safety when testing the fans. A suitable fan guard should be
fitted to the fan to guard against any potential for personal injury.
12. Except where specifically stated, all tests are carried out at room (ambient) temperature
and relative humidity conditions of 25oC, 65% RH. The test value is only for fan
performance itself.
13. Be certain to connect an “ 4.7µF or greater” capacitor to the fan externally when
the application calls for using multiple fans in parallel, to avoid any unstable power.
Doc. No: FMBG-ES Form 001 Rev. 0001
Date: June 24, 2009
很抱歉,暂时无法提供与“HET200PB”相匹配的价格&库存,您可以联系我们找货
免费人工找货