0
登录后你可以
  • 下载海量资料
  • 学习在线课程
  • 观看技术视频
  • 写文章/发帖/加入社区
会员中心
创作中心
发布
  • 发文章

  • 发资料

  • 发帖

  • 提问

  • 发视频

创作活动
HET200PB

HET200PB

  • 厂商:

    DELTA(台达)

  • 封装:

    Module

  • 描述:

    Air to Air Thermoelectric Assembly 200W 48V

  • 数据手册
  • 价格&库存
HET200PB 数据手册
Specification For Approval Customer : Description : Thermal Electric Cooling 200W Customer part no : Delta model no : Sample issue no : Sample issue date : Rev. : Rev. : HET200PB 03 JUN .21.2013 Modify history Rev. Description Drawn Approved Issue Date Nick Wang Diamond Chen 2012/1/18 Ted.Tu Diamond Chen 2012/12/12 00 ISSUE SPEC 01 Adding 2-4 & 6 02 Modify the noise. Nick Wang Diamond Chen 2013/4/16 03 Add the safety trademark Nick Wang Diamond Chen 2013/06/21 Please send one copy of this specification back after you signed approval for production pre-arrangement Approved by : Date : DELTA ELECTRONICS, INC. 252, SHANG YING ROAD, KUEI SAN TAOYUAN HSIEN 333, TAIWAN, R. O. C. Page 1 TEL : 886-(0)3-3591968 FAX : 886-(0)3-3591991 *** SAMPLE HISTORY*** CUSTOMER: CUSTOMER P/N: DELTA MODEL : HET200PB REV. DESCRIPTION DRAWN CHECKED ME EE 汪則鑫 1/18'12 涂雅森 1/18'12 CE ------ APPROVED 00 ISSUE SPEC 汪則鑫 1/18'12 01 Adding 2-4 & 6. 涂雅森 12/12'12 汪則鑫 12/12'12 涂雅森 12/12'12 ------ 陳李龍 12/12'12 12/12'12 02 Modify the noise 03 Add the safety trademark. 汪則鑫 4/16'13 汪則鑫 6/21'13 汪則鑫 4/16'13 汪則鑫 6/21'13 PAGE 1 OF 1 涂雅森 4/16'13 涂雅森 6/21'13 陳李龍 1/18'12 ISSUE DATE 1/18'12 ------ 陳李龍 4/16'13 ------ 陳李龍 6/21'13 4/16'13 6/21'13 History-000 Table of content 1. Description --------------------------------------------------------------------------------- 4 1-1. General description --------------------------------------------------------------- 4 1-2. 1-3. 1-4. 1-5. Main feature & model number --------------------------------------------------4 Dimension --------------------------------------------------------------------------- 5 Maintenance ------------------------------------------------------------------------ 7 Thermal path & Airflow baffle --------------------------------------------------- 8 2. Electrical specification ------------------------------------------------------------------ 9 2-1. Indicator & connector ------------------------------------------------------------- 9 2-2. Cooling Performance VS Temperature Difference ------------------------- 9 2-3. TEC work temperature range---------------------------------------------------- 9 2-4. Interface------------------------------------------------------------------------------- 10 3. Environmental condition --------------------------------------------------------------- 11 3-1. Operating temperature ----------------------------------------------------------- 11 3-2. Storage temperature -------------------------------------------------------------- 11 3-3. Humidity ------------------------------------------------------------------------------ 11 3-4. Protection rating -------------------------------------------------------------------- 11 3-5. MTBF---------------------------------------------------------------------------------- 11 4. Certified safety --------------------------------------------------------------------------- 12 4-1. UL , CUL, TUV, CE 5. User cable------ --------------------------------------------------------------------------- 12 5-1. Power cable 5-2. Alarm cable Page 2 Specification for approval Customer : Description : Thermal Electric Cooling 200W Customer P/N : Rev. : Delta model no. : HET200PB Rev. : 03 Sample revision : Issue no. : Sample issue date : Quantity : Page 3 sets Part no. : Delta model no. : HET200PB 1. Description 1-1. General description : The Thermal Electric Cooling (TEC) is designed for direct air to air heat removal in the cabinet. It is easy to be installed in the cabinet (recommended on the door of the cabinet) with the nuts. The internal and external air circulation loops of the TEC Module are separated to prevent the entry of dust, humidity and dirt. The unit conforms to IP55 protection rating on the external air circuit. 1-2. Main feature (Operating 48VDC at 25 ゚ C) Model Number Main feature Unit HET200PB Outline dimension mm 400 H x 180 W x 208 D Weight Kg 9.0 ± 0.5 Cooling capacity (△ △T =0 ℃) W 200 Heating capacity @-40 ゚ C W 225 Rated voltage VDC 48 (TYP.) Operating voltage range VDC 40~56 Rated Current A 6.7 (TYP.) Rated Consumption W 321.6 Operating temperature °C -40~55 Internal airflow rate 100 (TYP.) cfm External airflow rate 120 (TYP.) Acoustic noise at 1M : dB-A 61.0 dB-A(Typ.) (Sound pressure) Co o l in g a nd he a ti n g c apac it y i s f or in te r n a l s i de . Page 4 64.0(Max.) Part no. : Delta model no. : HET200PB 1-3. Dimension 1-3-1 Drawing (1) Material : case aluminum sheet , t=1.5mm (2) Finish : Power paint 75~120um, (3) Color : RAL 7032 (4) Dimension tolerance: X.X [X.XX] : ± 1.0mm [0.04”] X.XX [X.XXX] : ± 0.3mm [0.012”] Page 5 Part no. : Delta model no. : HET200PB 1-3-2 Mounting panel cutout : : : Page 6 Part no. : Delta model no. : HET200PB 1-4. Maintenance 1-4-1. Be sure to disconnect power supply before disassembly TEC module from customer cabinet. 1-4-2. Please refer to Delta authorized engineers for TEC module component replacement service, no allow unauthorized personnel to repair the unit. 1-4-3. If the replacement by user himself is necessary, please refer to the exploded drawing shown as previous page and below description for disassembly. External fan: Disassemble mounting screw of external fan via screw driver & pull out the connector. Internal fan: Disassemble mounting screw of internal fan via screw Driver & pull out the connector. Controller: Need to disassemble internal fan first , then pull-out all cable connection on controller , take off mounting screw of controller finally . TEC device: Due to TEC device have waterproof sealant protection and thermal conductive compound with heat-sink, please kindly ship back to Delta for replacement. Page 7 Part no. : Delta model no. : HET200PB 1-5. Thermal path and airflow baffle The thermal exchange path is shown in the figure below. Page 8 Part no. : Delta model no. : HET200PB 2. Electrical specification 2-1. Indicator & connector Connector " -48V VDC " mate with JWT C4201WR0-2*3PNL 2-2. Cooling Performance VS Temperature Difference 2-3. TEC work temperature range HET200PB has two work status, cooling and heating, according to the cabinet internal temperature (detect by on-board NTC). Page 9 Part no. : Delta model no. : HET200PB 2-4. Interface LED "FAN" (Green) : Fan normal (Red) : Fan failed (Blink Green) : Fan normal in test process (Blink Red) : Fan failed in test process LED "TEC" * (Green) : TEC normal (Red) : TEC failed (Blink green) : TEC normal in test process (Blink red) : TEC failed in test process or sensor failed LED "STATUS" (Green) : HET200PB work in cooling mode (Red) : HET200PB work in heating mode (Dark): HET200PB TEC function OFF CLEAN/TEST There is a auto test button on HET200PB, user can press this button to run HET200PB heating and cooling process, the process is about 7~8 mints. User can turn off this function by pressing this button again. *:HET200PB will detect internal fan income air temperature and sink surface temperature, It will compare two temperature to determine TEC is normal or not. Page 10 Part no. : Delta model no. : HET200PB Alarm dry contact: Pin to pin “Open”: Normal Pin to pin “Close”: Fan , TEC or sensor failed Connector "Alarm" Pin to Pin ----- MAX. ( ± 75VDC ) 50mA 3. Environmental conditions 3-1. Operating temperature : -40°C ~ +55°C ( 14°F ~ 149°F) 3-2. Storage temperature : -40°C ~ +65°C (-40°F ~ 149°F) 3-3. Humidity External air circuit: 0 ~ 100% RH Internal air circuit: 0 ~ 90% RH, Non-condensing 3-4. Protection rating IP55 (IEC60529) on external side with mounting on door. 3-5. MTBF Fan lifetime is expected to have a minimum L10 life of 80,000 hours continuous operation at 40°C with 15 ~ 65%RH at 48 voltage Page 11 Part no. : Delta model no. : HET200PB 4. Certified safety 4-1. UL , CUL, TUV, CE 5. User cable Each HET200PB will provide 2 cables with shipment. 5-1 Power cable 5-2 Alarm cable Page 12 Application Notice 1. Delta will not guarantee the performance of the products if the application condition falls outside the parameters set forth in the specification. 2. A written request should be submitted to Delta prior to approval if deviation from this specification is required. 3. Please exercise caution when handling fans. Damage may be caused when pressure is applied to the impeller, if the fans are handled by the lead wires, or if the fan was hard-dropped to the production floor. 4. Except as pertains to some special designs, there is no guarantee that the products will be free from any such safety problems or failures as caused by the introduction of powder, droplets of water or encroachment of insect into the hub. 5. The above-mentioned conditions are representative of some unique examples and viewed as the first point of reference prior to all other information. 6. It is very important to establish the correct polarity before connecting the fan to the power source. Positive (+) and Negative (-). Damage may be caused to the fans if connection is with reverse polarity, if there is no foolproof method to protect against such error specifically mentioned in this spec. 7. Delta fans without special protection are not suitable where any corrosive fluids are introduced to their environment. 8. Please ensure all fans are stored according to the storage temperature limits specified. Do not store fans in a high humidity environment. We highly recommend performance testing is conducted before shipping, if the fans have been stored over 6 months. 9. Not all fans are provided with the Lock Rotor Protection feature. If you impair the rotation of the impeller for the fans that do not have this function, the performance of those fans will lead to failure. 10. Please be cautious when mounting the fan. Incorrect mounting of fans may cause excess resonance, vibration and subsequent noise. 11. It is important to consider safety when testing the fans. A suitable fan guard should be fitted to the fan to guard against any potential for personal injury. 12. Except where specifically stated, all tests are carried out at room (ambient) temperature and relative humidity conditions of 25oC, 65% RH. The test value is only for fan performance itself. 13. Be certain to connect an “ 4.7µF or greater” capacitor to the fan externally when the application calls for using multiple fans in parallel, to avoid any unstable power. Doc. No: FMBG-ES Form 001 Rev. 0001 Date: June 24, 2009
HET200PB 价格&库存

很抱歉,暂时无法提供与“HET200PB”相匹配的价格&库存,您可以联系我们找货

免费人工找货