SPECIFICATION FOR APPROVAL
Customer :
Description : DC FAN
Customer Part No. :
Delta Model No. : THB1248CE
Sample Issue No. :
Sample Issue Date : APR.19 2016
REV. :
REV. :
00
PLEASE SEND ONE COPY OF THIS SPECIFICAITON BACK AFTER
YOU SIGNED APPROVAL FOR PRODUCTION PRE-ARRANGMENT.
APPROVED BY:
DATE
:
DELTA ELECTRONICS, INC.
TAOYUAN PLANT
252, SHANG YING ROAD, KUEI SAN INDUSTRIAL ZONE
TAOYUAN SHIEN, TAIWAN, R.O.C.
TEL:886-(0)3-3591968
FAX:886-(0)3-3591991
*** SAMPLE HISTORY***
CUSTOMER: STD.
CUSTOMER P/N: N.A
DELTA MODEL : THB1248CE
REV.
DESCRIPTION
00 ISSUE SPEC
01
CHECKED
ME
EE
劉文彬07/13'09 劉文彬07/13'09 楊坤昇07/13'09
DRAWN
CHANGE THE MIN PRESSURE MIN TO
劉文彬05/28'10
42.48 mmH2O ( 1.672 inchH2)
APPROVED
ISSUE
DATE
張楯成08/24'09
8/24'09
劉文彬05/28'10
楊坤昇05/28'10
---
張楯成05/28'10 05/31'10
劉文彬03/10'11
楊坤昇03/11'11
--
張楯成03/11'11 03/11'11
劉文彬03/15'11
楊坤昇03/15'11
---
張楯成08/09'11 08/09'11
劉文彬09/01'11
黃清彰09/01'11
---
陳建樺 09/01''11 09/01'11
楊朝富 11/10'15 楊朝富 11/10'15 謝宗融 11/10'15
---
張楯成 11/10'15 11/10'15
謝宗融 04/19'16 楊朝富 04/19'16 謝宗融 04/19'16
---
張楯成 04/19'16 04/19'16
CHANGE THE SPEED RANGE TO 7800+/10% & ADD THE SAFETY MARK &
02 CHANGE THE LENGTH OF WIRE STRIP
劉文彬03/10'11
&CHANGE THE MATERIAL OF FRAME
TO ALUMINUN AND WEIGHT
CURRECT THE LABEL MARK AND WIRE
03
劉文彬03/15'11
STRIP
04
CHANEGE WIRE STRIP TO 1007 #24 AND
劉文彬09/01'11
CHANGE TUBE P/N
05
CHANGE WIRE LENGTH FROM 260mm
TO 275mm
06 ADD PWM INTERFACE CIRCUIT
CE
-----
PAGE 2 OF 14
History-000
Delta Electronics, Inc.
No.252, Shanying Rd., Guishan Dist.,
Taoyuan City 333, Taiwan (R.O.C.)
TEL : 886-(0)3-3591968
FAX : 886-(0)3-3591991
STATEMENT OF DEVIATION
■ NONE
□ DESCRIPTION:
Delta Electronics, Inc.
No.252, Shanying Rd., Guishan Dist.,
Taoyuan City 333, Taiwan (R.O.C.)
TEL : 886-(0)3-3591968
FAX : 886-(0)3-3591991
Specification For Approval
Customer :
Description :
DC FAN
Customer P/N :
Delta model no. :
rev. :
THB1248CE
Sample revision. :
06
Sample issue date :
Delta Safety Model No.: THB1248CE
Issue no.:
Quantity :
1. SCOPE:
THIS SPECIFICATION DEFINES THE ELECTRICAL AND MECHANICAL
CHARACTERISTICS OF THE DC BRUSHLESS AXIAL FLOW FAN.
2. CHARACTERS:
ITEM
RATED VOLTAGE
OPERATION VOLTAGE
INPUT CURRENT (AVG.)
DESCRIPTION
48 VDC
36.0 - 60.0 VDC
0.95 (MAX. 1.14) A
SAFETY CURRENT ON LABEL : 1.14A
INPUT POWER(AVG)
SPEED
45.6 (MAX. 54.72) W
7800 ± 10% R.P.M.
3
MAX. AIR FLOW
(AT ZERO STATIC PRESSURE)
7.360 (MIN. 6.624) M /MIN.
262 (MIN. 235.80) CFM
MAX. AIR PRESSURE
(AT ZERO AIRFLOW)
51.44 (MIN. 41.67) mmH2O
2.025 (MIN. 1.640) inchH2O
ACOUSTICAL NOISE (AVG.)
INSULATION TYPE
CURRENT ON LABEL
70.0 (MAX 73.0) dB-A
UL: CLASS A
1.14A
(continued)
PAGE 1
PART NO:
DELTA MODEL:
THB1248CE
INSULATION STRENGT
DIELECTRIC STRENGTH
10 MEG OHM MIN. AT 500 VDC
(BETWEEN FRAME AND (+) TERMINAL)
5 mA MAX. AT 500 VAC 50/60 Hz ONE
MINUTE, (BETWEEN FRAME AND (+)
TERMINAL)
EXTERNAL COVER
LIFE EXPECTANCE (L10)
(AT LABEL VOLTAGE)
OPEN TYPE
70,000 HOURS CONTINUOUS OPERATION AT
40 °C WITH 15 ~ 65 %RH.
CLOCKWISE VIEW
FROM NAME PLATE SIDE
ROTATION
LOCKED CURRENT SHUT DOWN
LEAD WIRE
THE CURRENT WILL SHUT DOWN, WHEN
ROTOR LOCKED AND FIXED.
UL 1007 AWG #24
BLACK WIRE NEGATIVE(-)
RED WIRE POSITIVE(+)
BLUE WIRE FREQUENCY(F00 )
YELLOW WIRE SPEED CONTROL(PWM)
NOTES:
1. ALL READINGS ARE MEASURED AFTER STABLY WARMING UP
THROUGH 10 MINUTES.
2. STANDARD AIR PROPERTY IS AIR AT (Td) 25°C TEMPERATURE, (RH) 65%
RELATIVE HUMIDITY , AND (Pb) 760 mmHg BAROMETRIC PRESSURE.
3. THE VALUES WRITTEN IN PARENS , ( ), ARE LIMITED SPEC.
4. ACOUSTICAL NOISE MEASURING CONDITION:
PAGE 2
PART NO:
DELTA MODEL:
THB1248CE
3.MECHANICAL:
3-1. DIMENSIONS-------------------------------------------- SEE DIMENSIONS DRAWING
3-2. FRAME--------------------------------------------------------------- DIE-CAST ALUMINUM
3-3. IMPELLER-------------------------------------------------------------- PLASTIC UL: 94V-0
3-4. BEARING SYSTEM---------------------------------------------- TWO BALL BEARINGS
3-5. WEIGHT----------------------------------------------------------------------------- 415 GRAMS
4. ENVIRONMENTAL:
4-1. OPERATING TEMPERATURE------------------------------- -10 TO +70 DEGREE C
4-2. STORAGE TEMPERATURE---------------------------------- -40 TO +70 DEGREE C
4-3. OPERATING HUMIDITY---------------------------------------------------- 5 TO 90 % RH
4-4. STORAGE HUMIDITY------------------------------------------------------- 5 TO 90 % RH
5. PROTECTION:
5-1. LOCKED ROTOR PROTECTION
IMPEDANCE OF MOTOR WINDING PROTECTS MOTOR FROM FIRE IN
96 HOURS OF LOCKED ROTOR CONDITION AT THE RATED VOLTAGE.
5-2. POLARITY PROTECTION
BE CAPABLE OF WITHSTANDING IF REVERSE CONNECTION FOR
POSITIVE AND NEGATIVE LEADS.
6. RE OZONE DEPLETING SUBSTANCES:
6-1. NO CONTAINING PBBs, PBBOs, CFCs, PBBEs, PBDPEs AND HCFCs.
7. PRODUCTION LOCATION
7-1. PRODUCTS WILL BE PRODUCED IN CHINA OR THAILAND.
PAGE 3
PART NO:
DELTA MODEL:
THB1248CE
8. P & Q CURVE:
*TEST CONDITION: INPUT VOLTAGE-----OPERATION VOLTAGE
TEMPERATURE-----ROOM TEMPERATURE
HUMIDITY-----65%RH
PAGE 4
PART NO:
DELTA MODEL:
THB1248CE
9. DIMENSION DRAWING:
LABEL:
NOTES:
1. LEAD WIRE UL1007 AWG#24
BLACK WIRE ---- (-)
RED WIRE ---- (+)
YELLOW WIRE ---- (PWM)
BLUE WIRE ---- (F00)
2. TUBE: T4*0.55 105°C 600V BLACK UL, CSA APPROVED.
(DELTA P/N: 3227100800)
3.THIS PRODUCT IS ROHS COMPLIANT
PAGE 5
PART NO:
DELTA MODEL:
THB1248CE
10. FREQUENCY GENERATOR (FG) SIGNAL:
1. OUTPUT CIRCUIT - OPEN COLLECTOR MODE:
2. SPECIFICATION:
VCE(sat)= 0.5V MAX.
IC= 10mA MAX.
VFG = 60.0V MAX
R ≧ VFG /Ic
3. FREQUENCY GENERATOR WAVEFORM:
PULSES PER ROTAION
N=R.P.M
TS=60/N(SEC)
*VOLTAGE LEVEL AFTER BLADE LOCKED
*4 POLES
PAGE 6
PART NO:
DELTA MODEL:
THB1248CE
11. PWM CONTROL SIGNAL: (AT 48VDC ; 25 DEGREE C)
SIGNAL VOLTAGE RANGE: 0~10VDC
PWM SIGNAL WITH 5 VDC TTL OR CMOS LEVELS. THE PREFERRED
OPERATING POINT FOR THE FAN IS 20k HZ, AND DUTY CYCLE
FORM 0% TO 100%.
● AT 100% DUTY CYCLE,THE ROTOR WILL SPIN AT MAXIMUM SPEED.
● AT 0% DUTY CYCLE,THE ROTOR WILL STOP.
● WITH CONTROL SIGNAL LEAD DISCONNECTED,THE FAN WILL SPIN
AT MAXIMUM SPEED.
●
12. SPEED VS PWM CONTROL SIGNAL: (AT RATED VOLTAGE ; 25 DEGREE C
; PWM SIGNAL WITH 5 VDC TTL OR CMOS LEVELS & 20 KHZ)
DUTY CYCLE (%) SPEED R.P.M (REF.)CURRENT (A) T.Y.P.
100
7800±10%
0.95
50
4500±10%
0.30
0
0
0.01
13.PWM INPUT CIRCUIT
PAGE 7
Application Notice
1. Delta will not guarantee the performance of the products if the application condition
falls outside the parameters set forth in the specification.
2. A written request should be submitted to Delta prior to approval if deviation from
this specification is required.
3. Please exercise caution when handling fans. Damage may be caused when pressure is
applied to the impeller, if the fans are handled by the lead wires, or if the fan was
hard-dropped to the production floor.
4. Except as pertains to some special designs, there is no guarantee that the products will
be free from any such safety problems or failures as caused by the introduction of
powder, droplets of water or encroachment of insect into the hub.
5. The above-mentioned conditions are representative of some unique examples and viewed
as the first point of reference prior to all other information.
6. It is very important to establish the correct polarity before connecting the fan to the
power source. Positive (+) and Negative (-). Damage may be caused to the fans if
connection is with reverse polarity, if there is no foolproof method to protect against
such error specifically mentioned in this spec.
7. Delta fans without special protection are not suitable where any corrosive fluids are
introduced to their environment.
8. Please ensure all fans are stored according to the storage temperature limits specified.
Do not store fans in a high humidity environment. We highly recommend performance
testing is conducted before shipping, if the fans have been stored over 6 months.
9. Not all fans are provided with the Lock Rotor Protection feature. If you impair the
rotation of the impeller for the fans that do not have this function, the performance
of those fans will lead to failure.
10. Please be cautious when mounting the fan. Incorrect mounting of fans may cause
excess resonance, vibration and subsequent noise.
11. It is important to consider safety when testing the fans. A suitable fan guard should be
fitted to the fan to guard against any potential for personal injury.
12. Except where specifically stated, all tests are carried out at room (ambient) temperature
and relative humidity conditions of 25oC, 65% RH. The test value is only for fan
performance itself.
13. Be certain to connect an “ 4.7µF or greater” capacitor to the fan externally when
the application calls for using multiple fans in parallel, to avoid any unstable power.
Doc. No: FMBG-ES Form 001 Rev. 0001
Date: June 24, 2009
很抱歉,暂时无法提供与“THB1248CE”相匹配的价格&库存,您可以联系我们找货
免费人工找货