SPECIFICATION FOR APPROVAL
Customer :
Description : DC FAN
Customer Part No. NA
Delta Model No. : THD2348MU-00
Sample Issue No. :
Sample Issue Date : OCT.23.20209
REV. :
REV. :
00
PLEASE SEND ONE COPY OF THIS SPECIFICAITON BACK AFTER
YOU SIGNED APPROVAL FOR PRODUCTION PRE-ARRANGMENT.
APPROVED BY:
DATE
:
DELTA ELECTRONICS, INC.
TAOYUAN PLANT
252, SHANGYING ROAD, GUISHAN INDUSTRIAL ZONE,
TAOYUAN CITY 33341, TAIWAN
TEL:886-(0)3-3591968
FAX:886-(0)3-3591991
*** SAMPLE HISTORY***
CUSTOMER:
CUSTOMER P/N:
DELTA MODEL:
THD2348MU-00
REV.
DESCRIPTION
00
ISSUE SPEC
DRAWN
周子斌
DAVID.CHOU
10/23'20
CHECKED
ME
EE
周子斌
張家豪
DAVID.CHOU JAIHO.CHANG
10/23'20
10/23'20
CE
---
APPROVED
ISSUE
DATE
李健銘
JASON.LEE
謝清森
SEN.HSIEH
10/23'20
10/23'20
DELTA ELECTRONICS, INC.
252, SHANGYING ROAD, GUISHAN INDUSTRIAL ZONE,
TAOYUAN CITY 33341, TAIWAN
TEL : 886-(0)3-3591968
FAX : 886-(0)3-3591991
STATEMENT OF DEVIATION
■ NONE
□ DESCRIPTION:
DELTA ELECTRONICS, INC.
252, SHANGYING ROAD, GUISHAN INDUSTRIAL ZONE,
TAOYUAN CITY 33341, TAIWAN
TEL : 886-(0)3-3591968
FAX : 886-(0)3-3591991
Specification For Approval
Customer :
Description :
DC FAN
Customer P/N :
Delta model no. :
rev. :
THD2348MU-00
Delta Safety Model No.:
Sample revision. :
00
Issue no.:
Sample issue date :
OCT.23.2020
Quantity :
THD2348MU-00
1. SCOPE:
THIS SPECIFICATION DEFINES THE ELECTRICAL AND MECHANICAL
CHARACTERISTICS OF THE DC BRUSHLESS AXIAL FLOW FAN.
2. CHARACTERS:
ITEM
RATED VOLTAGE
OPERATION VOLTAGE
INPUT CURRENT(AVG.)
DESCRIPTION
48.0 VDC
36.0-60.0 VDC
3.75 (4.79 MAX.) A
( SAFETY CURRENT ON LABEL : 5.88A)
INPUT POWER(AVG.)
SPEED
MAX. AIR FLOW
(AT ZERO STATIC PRESSURE)
MAX. AIR PRESSURE
(AT ZERO AIRFLOW)
ACOUSTICAL NOISE (AVG.)
INSULATION TYPE
INSULATION STRENGTH
DIELECTRIC STRENGTH
180.0 (230.00 MAX.) W
5000 +10% RPM
25.909 (MIN. 23.319) M3 /MIN.
915.00 (MIN. 823.5) CFM
58.20 (MIN. 47.142) mmH2O
2.291(MIN. 1.856) inchH2O
70.0 (MAX. 74.0) dB-A
UL: CLASS A
10 MEG OHM MIN. AT 500 VDC
(BETWEEN FRAME AND (+) TERMINAL)
5 mA MAX. AT 500 VAC 50/60 Hz ONE MINUTE,
(BETWEEN FRAME AND (+) TERMINAL)
(continued)
PAGE 1
PART NO:
DELTA MODEL:
THD2348MU-00
LIFE EXPECTANCE (L10)
AT LABEL VOLTAGE
70,000 HOURS CONTINOUS OPERATION AT 40 °C
WITH 15 ~ 65 %RH.
ROTATION
CLOCKWISE VIEW FROM NAME PLATE SIDE
LOCKED CURRENT SHUT DOWN
THE CURRENT WILL SHUT DOWN WHEN ROTOR
LOCKED AND FIXED.
NOTES:
1. ALL READINGS ARE MEASURED AFTER STABLY WARMING UP
THROUGH 10 MINUTES.
2. STANDARD AIR PROPERTY IS AIR AT (Td) 25°C TEMPERATURE, (RH) 65%
RELATIVE HUMIDITY , AND (Pb) 760 mmHg BAROMETRIC PRESSURE.
3. THE VALUES WRITTEN IN PARENS , ( ), ARE LIMITED SPEC.
4. ACOUSTICAL NOISE MEASURING CONDITION:
NOISE IS MEASURED AT RATED VOLTAGE IN FREE AIR IN ANECHOIC
CHAMBER WITH B & K SOUND LEVEL METER WITH MICROPHONE AT
A DISTANCE OF ONE METER FROM THE FAN INTAKE.
PAGE 2
PART NO:
DELTA MODEL:
THD2348MU-00-5
3.MECHANICAL:
3-1. DIMENSIONS--------------------------------------------------- SEE DIMENSIONS DRAWING
3-2. FRAME------------------------------------------------------------------------------------ ALUMINUM
3-3. IMPELLER--------- PLASTIC BLACK UL: 94V-0(SECONDARY MATERIALS NOT ALLOWED)
3-4. BEARING SYSTEM----------------------------------------------------------- TWO BALL BEARINGS
3-5. WEIGHT---------------------------------------------------------------------------------------- 1600 GRAMS
3-6. ROTOR WEIGHT---------------------------------------------------------------------------- 530 GRAMS
3-7. SALT FOG TEST COMPLY----------------------------------------------------------------------- GR487
3-8. INGRESS PROTECTION RATING-------------------------------------------------------------IP55
4. ENVIRONMENTAL:
4-1. OPERATING TEMPERATURE------------------------------- -25 TO +70 DEGREE C
4-2. STORAGE TEMPERATURE---------------------------------- -40 TO +75 DEGREE C
4-3. OPERATING HUMIDITY---------------------------------------------------- 5 TO 90 % RH
4-3-1. OPERATING HUMIDITY AT 40 °C ----------------------------------- 5 TO 95 % RH
4-4. STORAGE HUMIDITY------------------------------------------------------ 5 TO 95 % RH
5. PROTECTION:
5-1. LOCKED ROTOR PROTECTION
IMPEDANCE OF MOTOR WINDING PROTECTS MOTOR FROM FIRE IN 96
HOURS OF LOCKED ROTOR CONDITION AT THE RATED VOLTAGE.
5-2. POLARITY PROTECTION
BE CAPABLE OF WITHSTANDING IF REVERSE CONNECTION FOR POSITIVE
AND NEGATIVE LEADS.
6. RE OZONE DEPLETING SUBSTANCES:
6-1. NO CONTAINING PBBs, PBBOs, CFCs, PBBEs, PBDPEs AND HCFCs.
7. PRODUCTION LOCATION
7-1. PRODUCTS WILL BE PRODUCED IN CHINA OR THAILAND .
PAGE 3
PART NO:
DELTA MODEL:
THD2348MU-00
8. P & Q CURVE:
*TEST CONDITION: INPUT VOLTAGE-----OPERATION VOLTAGE
TEMPERATURE-----ROOM TEMPERATURE
HUMIDITY-----65%RH
PAGE 4
PART NO:
DELTA MODEL:
THD2348MU-00
9. DIMENSION DRAWING:
PAGE 5
PART NO:
DELTA MODEL:
THD2348MU-00
10. FREQUENCY GENERATOR (FG) SIGNAL:
1. OUTPUT CIRCUIT - OPEN COLLECTOR MODE:
PAGE 6
PART NO:
DELTA MODEL:
THD2348MU-00
11. PWM CONTROL SIGNAL: (AT 48VDC ; 25 DEGREE C)
*THE PREFERRED OPERATING POINT FOR THE FAN IS 1KHz.
*THE FREQUENCY FOR CONTROL SIGNAL OF THE FAN SHALL BE
ABLE TO ACCEPT A 600Hz~30KHz.
*AT 100% DUTY CYCLE & 48VDC, THE ROTOR WILL SPIN AT MAXIMUM SPEED.
*AT 0% DUTY CYCLE & 48VDC, THE ROTOR WILL STOP.
*WITH CONTROL SIGNAL LEAD DISCONNECTED,THE FAN WILL SPIN
AT MAXIMUM SPEED.
*AT 48VDC 1KHz 30% DUTY CYCLE, THE FAN WILL BE ABLE TO START
FROM A DEAD STOP .
12. SPEED VS PWM CONTROL SIGNAL: (AT 48VDC & F=1KHz & TEMP=25 DEG.C)
13. PWM CONTROL LEAD WIRE INPUT IMPEDANCE:
PAGE 7
PART NO:
DELTA MODEL: THD2348MU-00
Fan Characteristics Informations for Reference
5. FRAME TYPE OF SCREW TORQUE
Application Notice
1. Delta will not guarantee the performance of the products if the application condition
falls outside the parameters set forth in the specification.
2. A written request should be submitted to Delta prior to approval if deviation from
this specification is required.
3. Please exercise caution when handling fans. Damage may be caused when pressure is
applied to the impeller, if the fans are handled by the lead wires, or if the fan was
hard-dropped to the production floor.
4. Except as pertains to some special designs, there is no guarantee that the products will
be free from any such safety problems or failures as caused by the introduction of
powder, droplets of water or encroachment of insect into the hub.
5. The above-mentioned conditions are representative of some unique examples and viewed
as the first point of reference prior to all other information.
6. It is very important to establish the correct polarity before connecting the fan to the
power source. Positive (+) and Negative (-). Damage may be caused to the fans if
connection is with reverse polarity, if there is no foolproof method to protect against
such error specifically mentioned in this spec.
7. Delta fans without special protection are not suitable where any corrosive fluids are
introduced to their environment.
8. Please ensure all fans are stored according to the storage temperature limits specified.
Do not store fans in a high humidity environment. We highly recommend performance
testing is conducted before shipping, if the fans have been stored over 6 months.
9. Not all fans are provided with the Lock Rotor Protection feature. If you impair the
rotation of the impeller for the fans that do not have this function, the performance
of those fans will lead to failure.
10. Please be cautious when mounting the fan. Incorrect mounting of fans may cause
excess resonance, vibration and subsequent noise.
11. It is important to consider safety when testing the fans. A suitable fan guard should be
fitted to the fan to guard against any potential for personal injury.
12. Except where specifically stated, all tests are carried out at room (ambient) temperature
and relative humidity conditions of 25oC, 65% RH. The test value is only for fan
performance itself.
13. Be certain to connect an “ 4.7µF or greater” capacitor to the fan externally when
the application calls for using multiple fans in parallel, to avoid any unstable power.
很抱歉,暂时无法提供与“THD2348MU-00”相匹配的价格&库存,您可以联系我们找货