Green
MURS140 - MURS160
1.0A SURFACE MOUNT SUPER-FAST RECTIFIER
Features
• • • • • • Glass Passivated Die Construction Super-Fast Recovery Time For High Efficiency Surge Overload Rating to 35A Peak Ideally Suited for Automated Assembly Lead Free Finish/RoHS Compliant (Note 1) Green Molding Compound (No Halogen and Antimony) (Note 2)
Mechanical Data
• • • • • • • • • Case: SMB Case Material: Molded Plastic. UL Flammability Classification Rating 94V-0 Moisture Sensitivity: Level 1 per J-STD-020 Terminals: Solder Plated Terminal - Solderable per MIL-STD202, Method 208 Lead Free Plating (Matte Tin Finish). Polarity: Cathode Band or Cathode Notch Marking Information: See Page 3 Ordering Information: See Page 3 Weight: 0.093 grams (approximate)
Top View
Bottom View
Maximum Ratings
@TA = 25°C unless otherwise specified
Single phase, half wave, 60Hz, resistive or inductive load. For capacitance load, derate current by 20%. Characteristic Peak Repetitive Reverse Voltage Working Peak Reverse Voltage DC Blocking Voltage (Note 7) RMS Reverse Voltage Average Rectified Output Current @ TT = 135°C Non-Repetitive Peak Forward Surge Current 8.3ms Single Half Sine-Wave Superimposed on Rated Load
Symbol VRRM VRWM VR VR(RMS) IO IFSM
MURS140 400 283 1.0 35
MURS160 600 424
Unit V V A A
Thermal Characteristics
Characteristic Typical Thermal Resistance, Junction to Terminal (Note 3) Operating Temperature Range Storage Temperature Range Symbol RθJT TJ TSTG Value 15 -55 to +150 -55 to +175 Unit °C/W °C °C
Electrical Characteristics
Characteristic Forward Voltage Peak Reverse Current at Rated DC Blocking Voltage (Note 7) Reverse Recovery Time (Note 5) Forward Recovery Time (Note 6) Typical Total Capacitance (Note 4)
Notes:
@TA = 25°C unless otherwise specified Symbol @ IF = 1.0A, TJ = 25°C @ IF = 1.0A, TJ = 150°C @ TA = 25°C @ TA = 150°C VFM IRM trr tf r CT Value 1.25 1.05 5.0 150 50 50 10 Unit V μA ns ns pF
1. EU Directive 2002/95/EC (RoHS). All applicable RoHS exemptions applied, see EU Directive 2002/95/EC Annex Notes. 2. Product manufactured with Data Code 0924 (week 24, 2009) and newer are built with Green Molding Compound. 3. Unit mounted on PC board with 5.0 mm2 (0.013 mm thick) copper pads as heat sink. 4. Measured at 1.0MHz and applied reverse voltage of 4V DC. 5. Measured with IF = 0.5A, IR = 1.0A, Irr = 0.25A. See Figure 5. 6. Measured with IF = 1.0A, di/dt = 100A/μs, Duty Cycle ≤ 2.0%. 7. Short duration pulse test used to minimize self-heating effect.
MURS140 - MURS160
Document number: DS30130 Rev. 10 - 2
1 of 4 www.diodes.com
September 2010
© Diodes Incorporated
MURS140 - MURS160
IO, AVERAGE FORWARD CURRENT (A)
Single Phase Half Wave 60Hz Resistive or Inductive Load
0 0 20 40 60 80 100 120 140 160 TT, TERMINAL TEMPERATURE (°C) Fig. 1 Forward Current Derating Curve
IFSM, PEAK FORWARD SURGE CURRENT (A)
Fig. 2 Typical Forward Characteristics
30
IR, REVERSE CURRENT (mA)
20
1.0
10
Pulse Width 8.3ms Single Half-Sine-Wave
0 1 2 5 10 20 50 100
0 20 40 120 140
NUMBER OF CYCLES AT 60Hz Fig. 3 Surge Current Derating Curve
VR, REVERSE VOLTAGE (V) Fig. 4 Typical Reverse Characteristics
MURS140 - MURS160
Document number: DS30130 Rev. 10 - 2
2 of 4 www.diodes.com
September 2010
© Diodes Incorporated
MURS140 - MURS160 Ordering Information (Note 8)
Part Number MURS140-13-F MURS160-13-F
Notes:
Case SMB SMB
Packaging 3000/Tape & Reel 3000/Tape & Reel
8. For packaging details, go to our website at http://www.diodes.com.
Marking Information
U1xB = Product type marking code U1GB = MURS140 U1JB = MURS160 = Manufacturers’ code marking YWW = Date code marking Y = Last digit of year (ex: 2 for 2002) WW = Week code (01 to 53)
YWW U1xB
Package Outline Dimensions
B
SMB Dim Min Max A 3.30 3.94 B 4.06 4.57 C 1.96 2.21 D 0.15 0.31 E 5.00 5.59 G 0.05 0.20 H 0.76 1.52 J 2.00 2.50 All Dimensions in mm
A
C
D
J
H
G E
Suggested Pad Layout
SMB Value (in mm) Dimensions Z 6.7 G 1.8 X 2.3 2.5 Y 4.3 C
MURS140 - MURS160
Document number: DS30130 Rev. 10 - 2
3 of 4 www.diodes.com
September 2010
© Diodes Incorporated
MURS140 - MURS160
IMPORTANT NOTICE DIODES INCORPORATED MAKES NO WARRANTY OF ANY KIND, EXPRESS OR IMPLIED, WITH REGARDS TO THIS DOCUMENT, INCLUDING, BUT NOT LIMITED TO, THE IMPLIED WARRANTIES OF MERCHANTABILITY AND FITNESS FOR A PARTICULAR PURPOSE (AND THEIR EQUIVALENTS UNDER THE LAWS OF ANY JURISDICTION). Diodes Incorporated and its subsidiaries reserve the right to make modifications, enhancements, improvements, corrections or other changes without further notice to this document and any product described herein. Diodes Incorporated does not assume any liability arising out of the application or use of this document or any product described herein; neither does Diodes Incorporated convey any license under its patent or trademark rights, nor the rights of others. Any Customer or user of this document or products described herein in such applications shall assume all risks of such use and will agree to hold Diodes Incorporated and all the companies whose products are represented on Diodes Incorporated website, harmless against all damages. Diodes Incorporated does not warrant or accept any liability whatsoever in respect of any products purchased through unauthorized sales channel. Should Customers purchase or use Diodes Incorporated products for any unintended or unauthorized application, Customers shall indemnify and hold Diodes Incorporated and its representatives harmless against all claims, damages, expenses, and attorney fees arising out of, directly or indirectly, any claim of personal injury or death associated with such unintended or unauthorized application. Products described herein may be covered by one or more United States, international or foreign patents pending. Product names and markings noted herein may also be covered by one or more United States, international or foreign trademarks. LIFE SUPPORT Diodes Incorporated products are specifically not authorized for use as critical components in life support devices or systems without the express written approval of the Chief Executive Officer of Diodes Incorporated. As used herein: A. Life support devices or systems are devices or systems which: 1. are intended to implant into the body, or 2. support or sustain life and whose failure to perform when properly used in accordance with instructions for use provided in the labeling can be reasonably expected to result in significant injury to the user. B. A critical component is any component in a life support device or system whose failure to perform can be reasonably expected to cause the failure of the life support device or to affect its safety or effectiveness.
Customers represent that they have all necessary expertise in the safety and regulatory ramifications of their life support devices or systems, and acknowledge and agree that they are solely responsible for all legal, regulatory and safety-related requirements concerning their products and any use of Diodes Incorporated products in such safety-critical, life support devices or systems, notwithstanding any devices- or systems-related information or support that may be provided by Diodes Incorporated. Further, Customers must fully indemnify Diodes Incorporated and its representatives against any damages arising out of the use of Diodes Incorporated products in such safety-critical, life support devices or systems. Copyright © 2010, Diodes Incorporated www.diodes.com
MURS140 - MURS160
Document number: DS30130 Rev. 10 - 2
4 of 4 www.diodes.com
September 2010
© Diodes Incorporated