FM-9038LM-5AN
IR Receiver Modules for Remote Control Systems
Description
The FM-9038LM-5AN is remote control receiver modules. Pin diode and receiver IC are assembled on one module. Small-sized, light-weight, and low current consumption. modules have been achieved by using resin mold. The demodulated output signal can directly be decoded by a microprocessor. The main benefit is the reliable function even in disturbed ambient and the protection against uncontrolled output pulses.
Features
Supply Voltage Range: 2.7V to 6.5V TTL and CMOS compatibility Photo detector and preamplifier in one package. Internal filter for PCM frequency Open collector output (built-in Pull-up resistor(40K) Output active low Enhanced Immunity against all kinds of disturbance light No occurrence of disturbance pulses at output pin within nominal conditions. Short settling time after power On.( below 1msec) Meet RoHS
Application Circuit
47~100Ω
IR Receiver Module VCC
VCC
47uf
VOUT
Transmitter
MCU
R-C filter recommended to suppress power supply disturbances. R-C filter should be connected closely between VCC pin and GND pin.
IC
GND
GND
Block Diagram
Ordering Info.(carrier frequencies)
Type
FM-9032LM-5AN FM-9036LM-5AN FM-9038LM-5AN FM-9040LM-5AN FM-9056LM-5AN
Carrier Frequency (fo) 32.7 K 36.7 K 37.9 K 40.0 K 56.7 K
光電企業有限公司
November 2006 Rev 1.3
FM-9038LM-5AN
Absolute Maximum Ratings
Parameter Supply Voltage Output Voltage Output Current Operating Temperature Storage Temperature Soldering Temperature Symbol VCC VOUT IOUT Topr Tstg Tsd Ratings 7.0 0.2 ~Vcc 2.5 -20 ~ +80 -30 ~ +85 260℃, Max 5 sec
(Ta = 25℃)
Unit V V mA ℃ ℃ ℃
Electro-optical Characteristics
Parameter Supply Voltage Supply Current Max input current Output Voltage Peak Wave Length Symbol Vcc ICC IIN Voh Vol Min. 2.7 0.8 0.5 Vcc-0.5 ±0˚ Arrival Distance L ±30˚ ±45˚ Max. Voltage Gain Internal Pull-up Resistor BPF Bandwidth BPF frequency Output Pulse width Av Rpul fbw fc Tpw 70 36 -3.5 450 Typ. 5.0 1.0 1.0 0.2 940 15 10 7 76 40 3.5 fo 600 Max. 6.5 1.3 1.5 0.4 82 44 +3.5 750 Unit V mA mA V V nm m m m dB ㏀ kHz % ㎲
(Ta = 25℃)
No input signal Vin=0 Vcc=5V
λp
Fig. 1,2,3 fin=37.9kHz Vin=30㎶pp
fin=37.9kHz Vin=30㎶pp
Fig. 1,2,6
光電企業有限公司
November 2006 Rev 1.3
FM-9038LM-5AN
[ Fig.1 ] Data Signal diagram Data Word t Pause
enlarge
Carrier Frequency : fo
t Burst
(Output pulse)
t Gap
t Gap : Signal gap time between two burst in pulses of carrier. Minimum Gap Time ≧ 300us t Burst : Length of a burst in pulses of the carrier frequency. Minimum Burst ≧ 300us t pause : Data pause between two data words. Minimum Data PauseTime ≧ 20ms
[ Fig.2 ] Transmitter
10K
VCC VOUT
S/Transmitter
PD
100uf
10K
30㎝
GND
※ The specifications shall be satisfied under the following conditions. The standard transmitter shall be specified of the burst wave form adjusted to VOUT 200mVp-p upon Po measuring circuit Standard Transmitter [ Fig.3 ] Test condition of arrival distance
Vout
osc
Transmitter GND Vcc : Indicates horizontal and vertical directions [ Measurement condition for arrival distance ]
☞ Ambient light source : Detecting surface illumination shall be irradiate 200±50Lux
under ordinary white fluorescence lamp without high frequency lighting
光電企業有限公司
November 2006 Rev 1.3
FM-9038LM-5AN
Electrical/Optical Characteristics
[ Fig.4 ] Supply Current vs. Voltage
2.5
[ Fig.5 ] Sensitivity vs. Supply Voltage
100 Relative Sensitivity(% ) 80 60 40 20 0
Supply Current(㎃)
2.0 1.5 1.0 0.5 0.0 2.5 3.0 3.5 4.0 4.5 5.0 5.5 6.0 6.5
2.5
3.0
3.5
4.0
4.5
5.0
5.5
6.0
6.5
Supply Voltage(V)
Supply Voltage(V)
[ Fig.6 ] Output Pulse Width vs. Distance
900
[ Fig.7 ] Directivity (Horizontal/Vertical)
0˚ 20˚ 40˚ Relative Radiant(˚)
Output Pulse Width(㎲)
800 700 600 500 400 300 0 4 8 12 16 20 24 28
80 60 40 20 0 Relative Sensitivity(%)
100 90
60˚
V H
80˚
Transmission Distance(m)
[ Fig.8 ] BPF Fc Curve
BPF fc 1.2
ESD Test Results
Parameter
1 Relative responsiv ity 0.8 0.6 0.4 0.2 0 0.5 0.6 0.7 0.8 0.9 1 1.1 1.2 1.3 f/fo Relative Frequency 1.4 1.5
Conditions C=200㎊ R=0Ω C=100pf R=1.5KΩ
Specification Min ±200V
Results >±200V
Machine Model Human Body Model
Min ±2000V
>±2000V
光電企業有限公司
November 2006 Rev 1.3
FM-9038LM-5AN
光電企業有限公司
November 2006 Rev 1.3
FM-9038LM-5AN
◆ Recommended Soldering Condition Flow Soldering Condition 2. Recommendation Flow Soldering condition Temp & Time
光電企業有限公司
November 2006 Rev 1.3
FM-9038LM-5AN
1. Packing unit for Remote control module
Package Transfer mold Type Device Packing Method Poly Bag Units / Tube 200 Poly Bag/ Inner Box Partial Max Devices / Max Inner Box / Shipment of Inner Box Outer Box Outer Box
5 1000 10 * Inner Box # 1 * Inner Box # 1 * Outer Box # 2 * Outer Box # 3 (unit : mm) Inner Box #1 with Opto-Sensor Logo (170*240*65) Outer Box #2 with Opto-Sensor Logo (365*360*270) Outer Box #3 with Opto-Sensor Logo (385*750*300)
2. Packing method
1) Input max 200 units to one Poly bag and label should be attached middle of it. Antistatic Vinyl
2) Input 5 poly bags to one inner box and label should be attached as below. Label #1
3) Input 10 inner boxes to outer box.
4) Input 2 outer boxes into Box #3.
光電企業有限公司
November 2006 Rev 1.3
很抱歉,暂时无法提供与“FM-9040LM-5AN”相匹配的价格&库存,您可以联系我们找货
免费人工找货