3412N/37GV
DC Axial Fan
25mm low profile fan with alarm output. The
DC drive employs an electronically commutated external rotor motor with high efficiency. An highly integrated IC implements
electronic motor commutation and the control
functions of the fan. Drive electronics are
completely integrated into the fan hub.
Features
General Data
•
Nominal voltage
V DC
12
Voltage range
V DC
8 .... 12,6
•
•
•
•
•
Electronical protection against reverse polarity, locked rotor, and overloading.
°C
30
50
Nominal speed
min-1
1600
2700
Integrated alarm output signal when
fan speed decreases alarm trip
speed.
Max. airflow
m3/h
50
84
Max. airflow
CFM
29,4
49,4
Electrical connection via 4 leads,
310mm, AWG24
Noise free air
dB(A)
16
32
Current consumption
mA
130
205
Power consumption
W
1,55
2,5
Perm. Ambient temperature
°C
-20 ... +65
Service life (40 °C)
h
70.000
Service life (70°C)
h
40.000
Air exhaust over struts. Rotational
direction CCW looking at rotor.
Extremely low EMI.
Speed control by temperature sensor
(temp.1=30°C; temp.2=50°C)
Temperature control
at max. voltage
Patents granted or applied for.
Approvals
UL, CSA, VDE
Fan housing / impeller
PBTP / PA
Bearing system
Mass
All data are mean values at nominal voltage.
ebm-papst St. Georgen GmbH & Co KG
Page 1 / 2
Sleeve bearings
g
100
Subject to technical change.
3412N_37GV.DOC
06.03.2008
Electrical connection
Operating voltage U(+) according to
admissible voltage range. Alarm supply voltage Uba ≤ 30V.
All voltages related to „Ground“.
(External pull-up resistor (Ra ) is
needed.
red
Temp.U(+)
blue
0V Ground
control
white
Ra
Isink
Uba
Ua
Uba
Isource
Temperature control
Alarm Circuit
This fan is equipped with an integrated alarm circuit producing a continuous output signal Ua for monitoring fan speed. At proper operation in
the nominal voltage range the alarm
output is a „high“ level.
When speed decreases below limit
speed nG = 0rpm, e.g. by high friction torques, locked rotor condition,
or low operating voltage, a „low“ level
output will occur.
When speed recovers, the alarm signal goes back to „high“, i.e. alarm is
non-latched.
Technical Data
Designation
Test condition
Alarm output voltage
Alarm signal level
Ua Low n = nG
Value
Uba
30V DC
n > nG
„High“
n < nG
„Low“
Isink = 2 mA
Ua High n > nG
Leakage current n > nG
Symbol
Uba = 30V
UaL
≤ 0,4V DC
UaH
Uba
Isink
max. 15µA
Max. sink current
Isink
10 mA
Alarm delay time
t2
none
Signal rise and
tr, tf
min. 0,5 V/µs
fall time Ua
(Stand. TTL)
Alarm trip speed
trÖLow-High-Flanke
nG
tfÖHigh-Low-
<
Alarm Diagram
Speed
0rpm
<
<
*
<
Alarm
supply
voltage
Alarm
signal
ebm-papst St. Georgen GmbH & Co KG
Page 2 / 2
<
3412N_37GV.DOC
06.03.2008