Max.
570 m /h
DC axial fans
3
119 x 38 mm
– Possible special versions:
Housing: Die-cast aluminum
(See chapter DC fans - specials)
Impeller: GRP1) (PA)
- Speed signal
Direction of air flow: Intake over struts
- Go / NoGo alarm
Direction of rotation: Clockwise, looking
- Alarm with speed limit
towards rotor
- External temperature sensor
Connection:
Via single wires AWG 18, 20 or
- Internal temperature sensor
AWG 22, TR 64, speed signal
- PWM control input (standard)
and control input AWG 22
- Analog control input
Highlights:
Highly efficient and smoothly
- Moisture protection
operating 3-phase fan drive
- Salt spray protection
Housing with grounding lug for
screw M4 x 8 (Torx)
Weight:
425 g
– Material:
–
–
–
–
–
m3/h
cfm
VDC
VDC
4114 N/2 H7P
500
294
24
16...30
76
8.5
90
9 500
-20...+75
57 500 / 25 000
97 500
4114 N/2 H8P
570
336
24
16...30
78
8.9
120
11 000
-20...+75
55 000 / 22 500
92 500
4118 N/2 H7P
500
294
48
36...60*
76
8.5
90
9 500
-20...+75
57 500 / 25 000
97 500
4118 N/2 H8P
570
336
48
36...60*
78
8.9
120
11 000
-20...+75
55 000 / 22 500
92 500
Subject to change
* 36...72 VDC on request.
dB(A) Bel(A)
Speed control range from 500 rpm-1 up to maximum nominal speed.
Standstill at 0% PWM, maximum speed if control cable is interrupted.
To attain the specified service life, an external capacitor must be wired
between the plus and minus strands. Please note the wiring suggestion on page 16.
** Power consumption at free air flow, these values can be significantly higher in the operating point.
** Power consumption - in operation
Fan type
optimum
operating range (W)
4114 NH7P
100
4114 NH8P
160
4118 NH7P
100
4118 NH8P
160
Tin-p
la
Air performance measured according to: ISO 5801.
Installation category A, without contact protection.
Noise: Total sound power level LWA ISO 103002
measured on a hemisphere with a radius of 2 m.
Sound pressure level LpA measured at 1 m distance
from fan axis.
The values given are applicable only under the specified
measuring conditions and may differ depending on the
installation conditions.
In the event of deviation from the standard configuration,
the parameters must be checked after installation!
For detailed information see
http://www.ebmpapst.com/general conditions
62
Finger guards
from p. 242
ted
Hours
Hours
Curve
Life expectancy L10IPC
(40 °C) see page 17
Service life L10 (Tmax)
ebm-papst standard
Type
Nominal data
2016-01
Service life L10 (40 °C)
ebm-papst standard
Temperature range
Power consumption**
Nominal speed
Sintec sleeve bearings
Ball bearings
Sound power level
°C
Voltage range
rpm-1
Nominal voltage
Watts
Air flow
/
Air flow
Series 4100 N
High Performance
Sound pressure level
1) Fiberglass-reinforced plastic
¿
¡
¿
¡
很抱歉,暂时无法提供与“4114N/2H8P”相匹配的价格&库存,您可以联系我们找货
免费人工找货- 国内价格
- 1+1536.63366
- 5+1466.76599
- 国内价格
- 1+1421.96036
- 5+1392.09971
- 10+1349.44019
- 25+1316.72410
- 50+1288.28104