Product Data Sheet 412 JHHU
The engineer's choice
Product Data Sheet 412 JHHU
412 JHHU
INDEX
1
General ...................................................................................................................................................................... 3
2
Mechanics ................................................................................................................................................................. 3
2.1
2.2
3
Operating Data .......................................................................................................................................................... 4
3.1
3.2
3.3
3.4
3.5
3.6
4
General .............................................................................................................................................................. 7
Climatic requirements*)...................................................................................................................................... 7
Safety ......................................................................................................................................................................... 9
5.1
5.2
6
Operating Data - Electrical Interface - Input ...................................................................................................... 4
Electrical Operating Data ................................................................................................................................... 5
Operating Data - Electrical Interface -Output .................................................................................................... 5
Electrical Features ............................................................................................................................................. 5
Aerodynamic ...................................................................................................................................................... 7
Sound Data ........................................................................................................................................................ 7
Environment .............................................................................................................................................................. 7
4.1
4.2
5
General .............................................................................................................................................................. 3
Connections ....................................................................................................................................................... 3
Electrical Safety ................................................................................................................................................. 9
Approval Tests ................................................................................................................................................... 9
Reliability ................................................................................................................................................................... 9
6.1
General .............................................................................................................................................................. 9
5/7/2012
page 2 of 10
Product Data Sheet 412 JHHU
1
General
Fan type
Rotational direction looking at rotor
Airflow direction
Bearing system
Mounting position
2
Mechanics
2.1
General
Width
Height
Depth
Weight
Housing material
Impeller material
Max. torque when mounted across both mounting
flanges
Screw size
2.2
Fan
counterclockwise
Air outlet over struts
Ball bearing
any
40,0 mm
40,0 mm
25,0 mm
0,050 kg
Plastic
Plastic
wire outlet corner: 60 Ncm
remaining corners: 60 Ncm
ISO 4762 - M3 degreased, without an additional
brace and without washer
Connections
Electrical connection
Length of lead wire
Wires
310 mm
+- 10,0 mm
Tolerance
Wire gauge (AWG)
Insulation diameter
Wire 1
Wire 2
26
1,35 mm
Colour
red
blue
Operation
+ UB
- GND
5/7/2012
page 3 of 10
Product Data Sheet 412 JHHU
3
Operating Data
3.1
Operating Data - Electrical Interface - Input
Control input
None
5/7/2012
page 4 of 10
Product Data Sheet 412 JHHU
3.2
Electrical Operating Data
Measurement
conditions:
Normal air density = 1,2 kg/m3; Temperature 23°C +/- 3°C; Motor axis horizontal;warm-up
time before measuring 5 minutes (unless otherwise specified).In the intake and outlet area
should not be any solid obstruction within 0,5 m.
∆p = 0:
I:
corresp. to free air flow (see section 3.5)
corresp. to arithm. mean current value
Features
Voltage range
Nominal voltage
Power consumption
Condition
∆p = 0
∆p = 0
∆p = 0
Tolerance
Current consumption
Tolerance
Speed
Tolerance
Symbol
U
UN
Values
8,0 V
13,5 V
P
1,5 W
+- 20,0 %
12,0 V
3,2 W
+- 20,0 %
I
190 mA
+- 20,0 %
270 mA
+- 20,0 %
310 mA
+- 20,0 %
8.500 1/min
+- 15,0 %
13.000 1/min
n
13.800 1/min
+- 15,0 %
0001
∆p = 0
0001
∆p = 0
0001
+ 10 %
Starting current
consumption
3.3
- 15 %
2.100 mA
Operating Data - Electrical Interface -Output
Tacho type
None
Alarm type
None
3.4
4,2 W
+- 20,0 %
Electrical Features
Electronic function
Reversed polarity protection
Max. residual current at Un
Locked rotor protection
Locked rotor current at Un
Clock signal t3/t4 at locked rotor
None
Rectifying diode
IF 10 MOhm
1,0 mm / 1,2 mm
III
Approval Tests
CE
UL
VDE
Yes
Yes
Yes / Approval acc. to EN 60950 (VDE 0805) - Information
technology equipment
Yes / C22.2 No. 113 Fans and Ventilators
No
CSA
CCC
The approval tests are observed to:
Maximal permitted operating voltage (see section 3.1) and max. permitted ambient temperature TU max.
6
Reliability
6.1
General
Life expectancy L10 at TU = 40 °C
Life expectancy L10 at TU max.
Life expectancy L10 Delta (40 °C)
57.500 h
35.000 h