0
登录后你可以
  • 下载海量资料
  • 学习在线课程
  • 观看技术视频
  • 写文章/发帖/加入社区
创作中心
发布
  • 发文章

  • 发资料

  • 发帖

  • 提问

  • 发视频

创作活动
4606ZWU-879

4606ZWU-879

  • 厂商:

    EBMPAPST(依必安派特)

  • 封装:

    -

  • 描述:

    FAN AXIAL 119X38MM 115VAC WIRE

  • 数据手册
  • 价格&库存
4606ZWU-879 数据手册
Product Data Sheet 4606 ZWU-879 The engineer's choice Product Data Sheet 4606 ZWU-879 4606 ZWU-879 INDEX 1 General ....................................................................................................................................................................... 3 2 Mechanics .................................................................................................................................................................. 3 2.1 2.2 3 Operating Data .......................................................................................................................................................... 5 3.1 3.2 3.3 3.4 3.5 4 GENERAL ............................................................................................................................................................. 8 CLIMATIC REQUIREMENTS*)................................................................................................................................... 8 Safety ......................................................................................................................................................................... 9 5.1 5.2 6 ELECTRICAL OPERATING DATA.............................................................................................................................. 5 OPERATING DATA - ELECTRICAL INTERFACE -OUTPUT ........................................................................................... 6 ELECTRICAL FEATURES ........................................................................................................................................ 6 AERODYNAMIC ..................................................................................................................................................... 6 SOUND DATA ....................................................................................................................................................... 7 Environment .............................................................................................................................................................. 8 4.1 4.2 5 GENERAL ............................................................................................................................................................. 3 CONNECTIONS...................................................................................................................................................... 4 ELECTRICAL SAFETY............................................................................................................................................. 9 APPROVAL TESTS ................................................................................................................................................. 9 Reliability ................................................................................................................................................................... 9 6.1 GENERAL ............................................................................................................................................................. 9 07/15/2014 page 2 of 10 Product Data Sheet 4606 ZWU-879 1 General Fan type Rotational direction looking at rotor Airflow direction Bearing system Mounting position Balancing grade 2 Mechanics 2.1 General Width Height Depth Diameter Weight Housing material Impeller material Max. torque when mounted across both mounting flanges Screw size Fan clockwise Air outlet over struts Ball bearing any 2,5 119,0 mm 119,0 mm 38,0 mm 0,0 mm 0,540 kg Metal Metal wire outlet corner: 120 Ncm remaining corners: 350 Ncm ISO 4762 - M4 degreased, without an additional brace and without washer 07/15/2014 page 3 of 10 Product Data Sheet 4606 ZWU-879 2.2 Connections Electrical connection Length of lead wire Wires L = 770,0 mm +- 10,0 mm Tolerance see drawing Length of tube Tolerance Wire gauge (AWG) Insulation diameter Plug Contact Wire 1 Wire 2 20 1,77 mm see drawing see drawing Colour white white Operation L N 07/15/2014 page 4 of 10 Product Data Sheet 4606 ZWU-879 3 Operating Data 3.1 Electrical Operating Data Measurement conditions: Normal air density = 1,2 kg/m3; Temperature 23°C +/- 3°C; Motor axis horizontal;warm-up time before measuring 5 minutes (unless otherwise specified). In the intake and outlet area should not be any solid obstruction within 0,5 m. ∆p = 0: corresp. to free air flow (see section 3.4) I: corresp. to RMS line current Features Condition Symbol Frequency ∆p = 0 f Nominal voltage ∆p = 0 UN ∆p = 0 P 19,0 W +- 10,0 % 17,0 W +- 10,0 % ∆p = 0 n 2.650 1/min +- 3,0 % 3.100 1/min +- 3,0 % Tolerance Power consumption Tolerance Speed Tolerance Values 50 Hz 115,0 V +- 10,0 % 07/15/2014 60 Hz 115,0 V +- 10,0 % page 5 of 10 Product Data Sheet 4606 ZWU-879 3.2 Operating Data - Electrical Interface -Output Tacho type 3.3 None Electrical Features Locked rotor protection Locked rotor current at Un 3.4 Impedance Aerodynamic Measurement conditions: Measured with a double chamber intake rig acc. to DIN EN ISO 5801. Normal air density = 1,2 kg/m3; Temperature 23°C +/- 3°C; In the intake and outlet area should not be any solid obstruction within 0,5 m. The information is only valid under the specified test conditions and may be changed by the installation conditions. If there are deviations from the standard test conditions, the characteristic values must be checked under the installed conditions. a.) Operation condition: 2.650 1/min at free air flow Max. free-air flow (∆p = 0 / = max.) Max. static pressure (∆p = max. / =0) b.) Operation condition: 3.100 1/min at free air flow Max. free-air flow (∆p = 0 / = max.) Max. static pressure (∆p = max. / =0) Frequency: 50 Hz 152,0 m3/h 70 Pa Frequency: 60 Hz 180,0 m3/h 80 Pa 07/15/2014 page 6 of 10 Product Data Sheet 4606 ZWU-879 3.5 Sound Data Measurement conditions: Sound pressure level: 1 Meter distance between microphone and the air intake. Sound power level: Acc. to DIN 45635 part 38 (ISO 10302) Measured in a semianchoic chamber with a background noise level of Lp(A) < 5 dB(A) For further measurement conditions see section 3.4 a.) Operation condition: 2.650 1/min at free air flow Frequency: 50 Hz Optimal operating point 130,0 m3/h @ 15 Pa Sound power level at the optimal operating point Sound pressure level at free air flow, measured in rubber bands 5,1 bel(A) b.) Operation condition: 3.100 1/min at free air flow 37,0 dB(A) Frequency: 60 Hz Optimal operating point 148,0 m3/h @ 20 Pa Sound power level at the optimal operating point Sound pressure level at free air flow, measured in rubber bands 5,5 bel(A) 42,0 dB(A) 07/15/2014 page 7 of 10 Product Data Sheet 4606 ZWU-879 4 Environment 4.1 General Min. permitted ambient temperature TU min. Max. permitted ambient temperature TU max. Min. permitted storage temperature TL min. Max. permitted storage temperature TL max. 4.2 -40 °C / 50 Hz -40 °C / 60 Hz 70 °C / 50 Hz 80 °C / 60 Hz -40 °C 100 °C Climatic requirements*) IP-protection type (certified) Humidity requirements IP 55 **) humid temperature, cyclic; according to DIN EN 60068-2-38, 10 cycle and condensation water check; according to DIN EN ISO 6270-2, 14 days Salt fog requirements None *) Permittet application area: The product is for the use in partial sheltered rooms or open, roofed areas. Direct exposure to water is allowed provided that this does not prevent the normal operation. Saline ambient conditions must be avoided. Pollution degree 3 (according DIN EN 60664-1) It occurs conductive pollution or dry non-conductive pollution which becomes conductive due to condensation. **) The specification of the IP protection refers to the conditions mentioned in certification of the fan. The above mentioned short description of the protection scope is not final. For detailed information of the respective protection scope and definitions, see certification as well as DIN EN 60529 (protection by housings) and ISO 20653 (for vehicles) with the letter K. Short description of the IP-protection type: Solid particle Protection: Protected against dust. Protection against deliberate contact: Protected against contact to hazardous parts with a wire. Protection against water: Protected against water jets. 07/15/2014 page 8 of 10 Product Data Sheet 4606 ZWU-879 5 Safety 5.1 Electrical Safety Dielectric strength DIN EN 60950 (VDE 0805) and DIN EN 60335 (VDE 0700) A.) Type test Measuring conditions: After 48h of storage at 95% R.H. and 25°C. No arcing or breakdown is allowed! All connections together to ground. B.) Routine test Measuring conditions: At indoor climate. No arcing or breakdown is allowed! All connections together to ground. Isolation resistance Measuring conditions: After 48h of storage at 95% R.H. and 25°C measured with U=500 VDC for 1 min. clearance / creepage distance Protection class 5.2 1000 VAC / 1 Min. 1500 VAC / 1 Sec. RI > 50 MOhm 2,0 mm / 1,1 mm I Approval Tests CE UL Yes Yes / UL507, Electric Fans Yes / Approval acc. to EN 60950 (VDE 0805) - Information technology equipment Yes / C22.2 No. 113 Fans and Ventilators Yes / GB 12350 Safety Requirements for small Power Motors VDE CSA CCC The approval tests are observed to: U approval max.: 115 V / f: 60 Hz @ TU approval max.: 85 °C 6 Reliability 6.1 General Life expectancy L10 at TU = 40 °C Life expectancy L10 at TU max. 37.500 h / 50 Hz 17.500 h / 50 Hz 07/15/2014 page 9 of 10
4606ZWU-879 价格&库存

很抱歉,暂时无法提供与“4606ZWU-879”相匹配的价格&库存,您可以联系我们找货

免费人工找货
4606ZWU-879
    •  国内价格
    • 1+815.80417
    • 50+716.67958
    • 150+564.92246

    库存:236