4656EZU

4656EZU

  • 厂商:

    EBMPAPST(依必安派特)

  • 封装:

  • 描述:

    风扇 管轴式 230VAC 圆形 - 109mm 直径 滚珠 83.6 CFM(2.34m³/min) 2 引线

  • 数据手册
  • 价格&库存
4656EZU 数据手册
product specification 9244014007 4656 EZU Customer specification: No Version: 1.0 Created: 22.12.2011 INDEX 1 General ...................................................................................................................................................................... 2 2 Mechanics ................................................................................................................................................................. 2 2.1 2.2 2.3 3 Operating Data ......................................................................................................................................................... 4 3.1 3.2 3.3 3.4 3.5 4 General ............................................................................................................................................................... 7 Climatic requirements ......................................................................................................................................... 7 Mechanical requirements .................................................................................................................................... 8 EMC .................................................................................................................................................................... 8 Safety ........................................................................................................................................................................ 8 5.1 5.2 6 Electrical Operating Data .................................................................................................................................... 4 Operating Data - Electrical Interface -Output ..................................................................................................... 4 Electrical Features .............................................................................................................................................. 5 Aerodynamic ....................................................................................................................................................... 5 Sound Data ......................................................................................................................................................... 7 Environment ............................................................................................................................................................. 7 4.1 4.2 4.3 4.4 5 General ............................................................................................................................................................... 2 Motor ................................................................................................................................................................... 2 Connections ........................................................................................................................................................ 3 Electrical Safety .................................................................................................................................................. 8 Approval Tests .................................................................................................................................................... 8 Reliability .................................................................................................................................................................. 8 6.1 6.2 General ............................................................................................................................................................... 9 Additional Data.................................................................................................................................................... 9 Special features according to QMH 2-5.4.7 and company standard 1-23.00 have the following definitions: "A" : Product features or process parameters which influence the safety of a product or the compliance of legal requirements. (Must not necessary verified and documented 100%. Standards and legal requirements must be considered.) "FK" : Product features or process parameters which influence the fit and function of a product or which have to be controlled or documented for some other reasons (e.g. Customer requirements). page 1 of 9 product specification 9244014007 1 General Fan type Rotational direction looking at rotor Airflow direction Bearing system Lubrication Mounting position Tolerance Balancing grade Impeller weight 2 Mechanics 2.1 General Width Height Depth Diameter Weight Surface protection Housing material Impeller material 2.2 Fan without chassis clockwise Air outlet over flange Ball bearing see sectional drawing of the bearing any 2,5 FK FK FK 0,0 mm 0,0 mm 39,0 mm 108,0 mm 0,380 kg see single part drawing of the housing, flange and impeller Metal Motor Type of motor Diameter of the motor Height of the motor Operating mode Insulation material class Shaded pole motor-extern rotor 40,0 mm 14,0 mm Continuous duty F page 2 of 9 product specification 9244014007 2.3 Connections Electrical connection Length of lead wire Wires 375,0 mm +- 10,0 mm Tolerance see drawing Length of tube Tolerance Wire gauge (AWG) Insulation diameter Plug Contact Wire 1 Wire 2 18 2,06 mm see drawing see drawing Colour black black Operation L N page 3 of 9 product specification 9244014007 3 Operating Data 3.1 Electrical Operating Data For checking purposes the electrical data can be specified without an intake nozzle / aperture plate as well. For this the data have to defined by the appropriate quality assurance. *) Attention: Marked values are "FK" features Electrical Operating Date with intake nozzel (For checking purposes) Measurement Normal air density = 1,2 kg/m3; Temperature 23°C +/- 3°C; Motor axis horizontal; warm-up conditions: time before measuring 5 minutes (unless otherwise specified). In the intake and outlet area should not be any solid obstruction within 0,5 m. Measurement setup: Measured with an aperture plate Aperture plate diameter: 109 mm Distance between mounting traverse and 20,5 mm aperture plate: ∆p = 0: corresp. to free air flow (see section 3.4) I: corresp. to RMS line current Features Frequency Nominal voltage Condition ∆p = 0 Symbol f ∆p = 0 UN Tolerance Power consumption Tolerance Values 50 Hz 230,0 V + 6,0 % ∆p = 0 P - 10,0 % 19,0 W +- 10,0 % ∆p = 0 I 115 mA *) +- 10,0 % 105 mA *) +- 10,0 % ∆p = 0 n 2.600 1/min *) +- 3,0 % 2.950 1/min *) +- 3,0 % Current consumption Tolerance Speed Tolerance 60 Hz 230,0 V + 6,0 % - 10,0 % 18,0 W +- 10,0 % *) Attention: Marked values are "FK" features 3.2 Operating Data - Electrical Interface -Output Tacho type None page 4 of 9 product specification 9244014007 3.3 Electrical Features Locked rotor protection Locked rotor current at Un 3.4 Impedance A Aerodynamic Measurement conditions: Measured with a double chamber intake rig acc. to DIN EN ISO 5801. Normal air density = 1,2 kg/m3; Temperature 23°C +/- 3°C; In the intake and outlet area should not be any solid obstruction within 0,5 m. Measurement setup: Measured with an aperture plate Aperture plate diameter: 109 mm Distance between mounting traverse and 20,5 mm aperture plate: a.) Operation condition: 2.600 1/min at free air flow Max. free-air flow (∆p = 0 / = max.) Max. static pressure (∆p = max. / =0) b.) Operation condition: 2.950 1/min at free air flow Max. free-air flow (∆p = 0 / = max.) Max. static pressure (∆p = max. / =0) Frequency: 50 Hz 124,0 m3/h 72 Pa FK FK Frequency: 60 Hz 142,0 m3/h 77 Pa FK FK page 5 of 9 product specification 9244014007 Measured with Traverse, 4000 TZ series. Nozzle is set at middle of the rotor. page 6 of 9 product specification 9244014007 3.5 Sound Data Measurement conditions: Sound pressure level: 1 Meter distance between microphone and the air intake. Sound power level: Acc. to DIN 45635 part 38 (ISO 10302) Measured in a semianchoic chamber with a background noise level of Lp(A) < 5 dB(A) For further measurement conditions see section 3.4 a.) Operation condition: 2.600 1/min at free air flow Frequency: 50 Hz Optimal operating point Sound power level at the optimal operating point Sound pressure level at free air flow, measured in rubber bands b.) Operation condition: 2.950 1/min at free air flow 39,0 dB(A) Frequency: 60 Hz Optimal operating point Sound power level at the optimal operating point Sound pressure level at free air flow, measured in rubber bands 42,0 dB(A) Measured with Traverse, 4000 TZ series. 4 Environment 4.1 General Min. permitted ambient temperature TU min. Max. permitted ambient temperature TU max. Min. permitted storage temperature TL min. Max. permitted storage temperature TL max. -40 °C / 50 Hz -40 °C / 60 Hz 65 °C / 50 Hz 70 °C / 60 Hz -40 °C 80 °C To meet the same ambient temperatures as for conventional fan casings, a good thermal connection between flange and customer application should be ensured. 4.2 Climatic requirements*) Humidity requirements humid temperature, cyclic; according to DIN EN 60068-2-38, 10 cycle and condensation water check; according to DIN EN ISO 6270-2, 14 days Water exposure Splash water check IPX4; according to DIN EN 60529 VDE 0470, not certified Solar radiation; according to DIN EN 60068-2-5 Dust check IP5X; according to DIN EN 60529 VDE 0470, not certified Radiation exposure Dust requirements page 7 of 9 product specification 9244014007 Salt fog requirements Harmful gas requirements None None *) Permittet application area: The product is for the use in partial sheltered rooms or open, roofed areas. Directly exposure to water is allowed in so far as this doesn´t prevent the normal operation. Saline ambient conditions must be avoid. Pollution degree 3 (according DIN EN 60664-1) It occurs conductive pollution or dry non-conductive pollution occurs that becomes conductive due to condensation. 4.3 Mechanical requirements Please require severity levels and specification parameters from the responsible development departmentsEMC not specified 5 Safety 5.1 Electrical Safety Dielectric strength DIN EN 60950 (VDE 0805) and DIN EN 60335 (VDE 0700) A.) Type test Measuring conditions: After 48h of storage at 95% R.H. and 25°C. No arcing or breakdown is allowed! All connections together to ground. B.) Routine test Measuring conditions: At indoor climate. No arcing or breakdown is allowed! All connections together to ground. Isolation resistance Measuring conditions: After 48h of storage at 95% R.H. and 25°C measured with U=500 VDC for 1 min. Air and leakage distances Protection class 5.2 1500 VAC / 1 Min. 1500 VAC / 1 Sec. A RI > 50 MOhm 2,0 mm / 1,8 mm I Approval Tests CE UL Yes Yes / UL507, Electric Fans Yes / Approval acc. to EN 60950 (VDE 0805) - Information technology equipment No Yes / GB 12350 Safety Requirements for small Power Motors VDE CSA CCC The approval tests are observed to: U approval max.: 230 V / f: 60 Hz @ TU approval max.: 65 °C 6 Reliability page 8 of 9 product specification 9244014007 6.1 General Life expectancy L10 at TU = 40 °C Life expectancy L10 at TU max. Life expectancy L10 acc. to IPC 9591 at TU = 40 °C 6.2 37.500 h / 50 Hz 15.000 h / 50 Hz / 50 Hz Additional Data not specified page 9 of 9
4656EZU 价格&库存

很抱歉,暂时无法提供与“4656EZU”相匹配的价格&库存,您可以联系我们找货

免费人工找货
4656EZU
  •  国内价格 香港价格
  • 1+781.208641+93.80867
  • 10+702.1180810+84.31136
  • 25+692.2257125+83.12347
  • 50+647.7252450+77.77979
  • 100+632.89236100+75.99864

库存:8