product specification 9244014007
4656 EZU
Customer specification: No
Version: 1.0
Created: 22.12.2011
INDEX
1
General ...................................................................................................................................................................... 2
2
Mechanics ................................................................................................................................................................. 2
2.1
2.2
2.3
3
Operating Data ......................................................................................................................................................... 4
3.1
3.2
3.3
3.4
3.5
4
General ............................................................................................................................................................... 7
Climatic requirements ......................................................................................................................................... 7
Mechanical requirements .................................................................................................................................... 8
EMC .................................................................................................................................................................... 8
Safety ........................................................................................................................................................................ 8
5.1
5.2
6
Electrical Operating Data .................................................................................................................................... 4
Operating Data - Electrical Interface -Output ..................................................................................................... 4
Electrical Features .............................................................................................................................................. 5
Aerodynamic ....................................................................................................................................................... 5
Sound Data ......................................................................................................................................................... 7
Environment ............................................................................................................................................................. 7
4.1
4.2
4.3
4.4
5
General ............................................................................................................................................................... 2
Motor ................................................................................................................................................................... 2
Connections ........................................................................................................................................................ 3
Electrical Safety .................................................................................................................................................. 8
Approval Tests .................................................................................................................................................... 8
Reliability .................................................................................................................................................................. 8
6.1
6.2
General ............................................................................................................................................................... 9
Additional Data.................................................................................................................................................... 9
Special features according to QMH 2-5.4.7 and company standard 1-23.00 have the following definitions:
"A" : Product features or process parameters which influence the safety of a product or the compliance of legal
requirements. (Must not necessary verified and documented 100%. Standards and legal requirements must be
considered.)
"FK" : Product features or process parameters which influence the fit and function of a product or which have to be
controlled or documented for some other reasons (e.g. Customer requirements).
page 1 of 9
product specification 9244014007
1
General
Fan type
Rotational direction looking at rotor
Airflow direction
Bearing system
Lubrication
Mounting position
Tolerance
Balancing grade
Impeller weight
2
Mechanics
2.1
General
Width
Height
Depth
Diameter
Weight
Surface protection
Housing material
Impeller material
2.2
Fan without chassis
clockwise
Air outlet over flange
Ball bearing
see sectional drawing of the bearing
any
2,5
FK
FK
FK
0,0 mm
0,0 mm
39,0 mm
108,0 mm
0,380 kg
see single part drawing of the housing, flange and
impeller
Metal
Motor
Type of motor
Diameter of the motor
Height of the motor
Operating mode
Insulation material class
Shaded pole motor-extern rotor
40,0 mm
14,0 mm
Continuous duty
F
page 2 of 9
product specification 9244014007
2.3
Connections
Electrical connection
Length of lead wire
Wires
375,0 mm
+- 10,0 mm
Tolerance
see drawing
Length of tube
Tolerance
Wire gauge (AWG)
Insulation diameter
Plug
Contact
Wire 1
Wire 2
18
2,06 mm
see drawing
see drawing
Colour
black
black
Operation
L
N
page 3 of 9
product specification 9244014007
3
Operating Data
3.1
Electrical Operating Data
For checking purposes the electrical data can be specified without an intake nozzle / aperture plate as well. For this
the data have to defined by the appropriate quality assurance.
*) Attention: Marked values are "FK" features
Electrical Operating Date with intake nozzel (For checking purposes)
Measurement
Normal air density = 1,2 kg/m3; Temperature 23°C +/- 3°C; Motor axis horizontal; warm-up
conditions:
time before measuring 5 minutes (unless otherwise specified).
In the intake and outlet area should not be any solid obstruction within 0,5 m.
Measurement setup:
Measured with an aperture plate
Aperture plate diameter:
109 mm
Distance between mounting traverse and 20,5 mm
aperture plate:
∆p = 0: corresp. to free air flow (see section 3.4)
I:
corresp. to RMS line current
Features
Frequency
Nominal voltage
Condition
∆p = 0
Symbol
f
∆p = 0
UN
Tolerance
Power consumption
Tolerance
Values
50 Hz
230,0 V
+ 6,0 %
∆p = 0
P
- 10,0 %
19,0 W
+- 10,0 %
∆p = 0
I
115 mA *)
+- 10,0 %
105 mA *)
+- 10,0 %
∆p = 0
n
2.600 1/min *)
+- 3,0 %
2.950 1/min *)
+- 3,0 %
Current consumption
Tolerance
Speed
Tolerance
60 Hz
230,0 V
+ 6,0 %
- 10,0 %
18,0 W
+- 10,0 %
*) Attention: Marked values are "FK" features
3.2
Operating Data - Electrical Interface -Output
Tacho type
None
page 4 of 9
product specification 9244014007
3.3
Electrical Features
Locked rotor protection
Locked rotor current at Un
3.4
Impedance
A
Aerodynamic
Measurement
conditions:
Measured with a double chamber intake rig acc. to DIN EN ISO 5801.
Normal air density = 1,2 kg/m3; Temperature 23°C +/- 3°C;
In the intake and outlet area should not be any solid obstruction within 0,5 m.
Measurement setup:
Measured with an aperture plate
Aperture plate diameter:
109 mm
Distance between mounting traverse and 20,5 mm
aperture plate:
a.) Operation condition:
2.600 1/min at free air flow
Max. free-air flow (∆p = 0 / = max.)
Max. static pressure (∆p = max. / =0)
b.) Operation condition:
2.950 1/min at free air flow
Max. free-air flow (∆p = 0 / = max.)
Max. static pressure (∆p = max. / =0)
Frequency: 50 Hz
124,0 m3/h
72 Pa
FK
FK
Frequency: 60 Hz
142,0 m3/h
77 Pa
FK
FK
page 5 of 9
product specification 9244014007
Measured with Traverse, 4000 TZ series. Nozzle is set at middle of the rotor.
page 6 of 9
product specification 9244014007
3.5
Sound Data
Measurement
conditions:
Sound pressure level: 1 Meter distance between microphone and the air intake.
Sound power level: Acc. to DIN 45635 part 38 (ISO 10302)
Measured in a semianchoic chamber with a background noise level of Lp(A) < 5 dB(A)
For further measurement conditions see section 3.4
a.) Operation condition:
2.600 1/min at free air flow
Frequency: 50 Hz
Optimal operating point
Sound power level at the optimal operating
point
Sound pressure level at free air flow,
measured in rubber bands
b.) Operation condition:
2.950 1/min at free air flow
39,0 dB(A)
Frequency: 60 Hz
Optimal operating point
Sound power level at the optimal operating
point
Sound pressure level at free air flow,
measured in rubber bands
42,0 dB(A)
Measured with Traverse, 4000 TZ series.
4
Environment
4.1
General
Min. permitted ambient temperature TU min.
Max. permitted ambient temperature TU max.
Min. permitted storage temperature TL min.
Max. permitted storage temperature TL max.
-40 °C / 50 Hz
-40 °C / 60 Hz
65 °C / 50 Hz
70 °C / 60 Hz
-40 °C
80 °C
To meet the same ambient temperatures as for conventional fan casings, a good thermal connection between flange
and customer application should be ensured.
4.2
Climatic requirements*)
Humidity requirements
humid temperature, cyclic; according to DIN EN
60068-2-38, 10 cycle and condensation water
check; according to DIN EN ISO 6270-2, 14 days
Water exposure
Splash water check IPX4; according to DIN EN
60529 VDE 0470, not certified
Solar radiation; according to DIN EN 60068-2-5
Dust check IP5X; according to DIN EN 60529 VDE
0470, not certified
Radiation exposure
Dust requirements
page 7 of 9
product specification 9244014007
Salt fog requirements
Harmful gas requirements
None
None
*) Permittet application area:
The product is for the use in partial sheltered rooms or open, roofed areas. Directly exposure to water is allowed in so
far as this doesn´t prevent the normal operation. Saline ambient conditions must be avoid.
Pollution degree 3 (according DIN EN 60664-1)
It occurs conductive pollution or dry non-conductive pollution occurs that becomes conductive due to condensation.
4.3
Mechanical requirements
Please require severity levels and specification parameters from the responsible development departmentsEMC
not specified
5
Safety
5.1
Electrical Safety
Dielectric strength
DIN EN 60950 (VDE 0805) and DIN EN 60335 (VDE
0700)
A.) Type test
Measuring conditions: After 48h of storage at 95%
R.H. and 25°C.
No arcing or breakdown is allowed!
All connections together to ground.
B.) Routine test
Measuring conditions: At indoor climate.
No arcing or breakdown is allowed!
All connections together to ground.
Isolation resistance
Measuring conditions: After 48h of storage at 95%
R.H. and 25°C measured with U=500 VDC for 1 min.
Air and leakage distances
Protection class
5.2
1500 VAC / 1 Min.
1500 VAC / 1 Sec.
A
RI > 50 MOhm
2,0 mm / 1,8 mm
I
Approval Tests
CE
UL
Yes
Yes / UL507, Electric Fans
Yes / Approval acc. to EN 60950 (VDE 0805) - Information
technology equipment
No
Yes / GB 12350 Safety Requirements for small Power Motors
VDE
CSA
CCC
The approval tests are observed to:
U approval max.: 230 V / f: 60 Hz @ TU approval max.: 65 °C
6
Reliability
page 8 of 9
product specification 9244014007
6.1
General
Life expectancy L10 at TU = 40 °C
Life expectancy L10 at TU max.
Life expectancy L10 acc. to IPC 9591 at TU = 40 °C
6.2
37.500 h / 50 Hz
15.000 h / 50 Hz
/ 50 Hz
Additional Data
not specified
page 9 of 9