Product Data Sheet # 6248 NI
Product Data Sheet # 6248 NI
# 6248 NI
INDEX
1
General ...................................................................................................................................................................... 3
2
Mechanics ................................................................................................................................................................. 3
2.1
2.2
3
Operating Data ......................................................................................................................................................... 5
3.1
3.2
3.3
3.4
3.5
3.6
4
General .............................................................................................................................................................. 9
Climatic requirements*) ..................................................................................................................................... 9
Safety ...................................................................................................................................................................... 10
5.1
5.2
6
Operating Data - Electrical Interface - Input ...................................................................................................... 5
Electrical Operating Data .................................................................................................................................. 6
Operating Data - Electrical Interface -Output .................................................................................................... 7
Electrical Features ............................................................................................................................................. 7
Aerodynamic...................................................................................................................................................... 8
Sound Data........................................................................................................................................................ 9
Environment ............................................................................................................................................................. 9
4.1
4.2
5
General .............................................................................................................................................................. 3
Connections....................................................................................................................................................... 3
Electrical Safety ............................................................................................................................................... 10
Approval Tests ................................................................................................................................................ 10
Reliability ................................................................................................................................................................ 10
6.1
General ............................................................................................................................................................ 10
02/12/2015
page 2 of 11
Product Data Sheet # 6248 NI
1
General
Fan type
Rotational direction looking at rotor
Airflow direction
Bearing system
Mounting position
2
Mechanics
2.1
General
Depth
Diameter
Weight
Housing material
Impeller material
Max. torque when mounted across both mounting
flanges
Screw size
2.2
Fan
counterclockwise
Air outlet over struts
Ball bearing
any
51,0 mm
172,0 mm
0,780 kg
Metal
Plastic
wire outlet corner: 600 Ncm
remaining corners: 600 Ncm
ISO 4762 - M4 degreased, without an additional
brace and without washer
Connections
Electrical connection
Length of lead wire
Plug
Tolerance
Wire gauge (AWG)
Insulation diameter
Contact
see drawing
02/12/2015
page 3 of 11
Product Data Sheet # 6248 NI
02/12/2015
page 4 of 11
Product Data Sheet # 6248 NI
3
Operating Data
3.1
Operating Data - Electrical Interface - Input
Control input
Internal Temperature Sensor
Features
Characteristics
Schematics
02/12/2015
page 5 of 11
Product Data Sheet # 6248 NI
3.2
Electrical Operating Data
Measurement
conditions:
∆p = 0:
I:
Name
TU 0001
NTC 0001
Normal air density = 1,2 kg/m3; Temperature 23°C +/- 3°C; Motor axis horizontal;warm-up
time before measuring 5 minutes (unless otherwise specified).In the intake and outlet area
should not be any solid obstruction within 0,5 m.
corresp. to free air flow (see section 3.5)
corresp. to arithm. mean current value
Condition
TU: >= 50 °C
Features
Voltage range
Nominal voltage
Power consumption
Condition
∆p = 0
∆p = 0
∆p = 0
Tolerance
TU / NTC
0001
∆p = 0
Current consumption
Tolerance
Speed
Tolerance
TU / NTC
0001
∆p = 0
TU / NTC
0001
Symbol
U
UN
P
I
n
Values
28,0 V
60,0 V
4,5 W
+- 15,0 %
48,0 V
16,0 W
+- 15,0 %
21,0 W
+- 15,0 %
160 mA
+- 15,0 %
335 mA
+- 15,0 %
350 mA
+- 15,0 %
2.150 1/min
+- 10,0 %
3.400 1/min
+- 8,0 %
3.820 1/min
+- 10,0 %
Starting current
consumption
Inrush current
= 50 °C or broken Sensor.
02/12/2015
page 6 of 11
Product Data Sheet # 6248 NI
Name
TU 0002
NTC 0002
Condition
TU: = 50 °C
Optimal operating point
285,0 m3/h @ 58 Pa
Sound power level at the optimal operating
point
Sound pressure level at free air flow,
measured in rubber bands
6,1 bel(A)
4
Environment
4.1
General
Min. permitted ambient temperature TU min.
Max. permitted ambient temperature TU max.
Min. permitted storage temperature TL min.
Max. permitted storage temperature TL max.
4.2
55,0 dB(A)
-10 °C
72 °C
-40 °C
80 °C
Climatic requirements*)
Humidity requirements
Water exposure
Dust requirements
Salt fog requirements
humid heat, constant; according to DIN EN 60068-278, 14 days
None
None
None
*) Permittet application area:
The product is intended for use in sheltered rooms with controlled temperature and controlled humidity. Directly
exposure to water must be avoided.
Pollution degree 1 (according DIN EN 60664-1)
There is either no pollution or it occurs only dry, non-conductive pollution. The pollution has no negative impact.
02/12/2015
page 9 of 11
Product Data Sheet # 6248 NI
5
Safety
5.1
Electrical Safety
Dielectric strength
DIN EN 60950 (VDE 0805) and DIN EN 60335 (VDE
0700)
A.) Type test
Measuring conditions: After 48h of storage at 95%
R.H. and 25°C.
No arcing or breakdown is allowed!
All connections together to ground.
B.) Routine test
Measuring conditions: At indoor climate.
No arcing or breakdown is allowed!
All connections together to ground.
Isolation resistance
Measuring conditions: After 48h of storage at 95%
R.H. and 25°C measured with U=500 VDC for 1 min.
clearance / creepage distance
Protection class
5.2
CE
EAC
UL
VDE
CSA
CCC
500 VAC / 1 Min.
500 VAC / 1 Sec.
RI > 10 MOhm
1,0 mm / 1,5 mm
III
Approval Tests
EC Declaration of Conformity
Eurasian Conformity
Underwriters Laboratories
Association for Electrical, Electronic and Information
Technologies
Canadian Standards Association
China Compulsory Certification
6
Reliability
6.1
General
Life expectancy L10 at TU = 40 °C
Life expectancy L10 at TU max.
Life expectancy L10 IPC (40 °C)
No
Yes
Yes / UL507, Electric Fans
Yes / Approval acc. to EN 60950 (VDE 0805) - Information
technology equipment
Yes / CSA audited by UL according to C22.2 No. 113 Fans
and Ventilators
Yes / GB 12350 Safety Requirements for small Power Motors
75.000 h
35.000 h
127.500 h
02/12/2015
page 10 of 11
很抱歉,暂时无法提供与“6248NI”相匹配的价格&库存,您可以联系我们找货