8314/19H
DC Axial Fan
80mm axial fan with high air flow. The
DC drive employs an electronically
commutated external rotor motor with
high efficiency. Drive electronics is completely integrated into the fan hub. The
air flow and noise level can be controlled
by varying the supply voltage range.
General Data
Nominal voltage
V DC
24
Features
Voltage range
V DC
12 ... 26.5
•
Nominal speed
rpm
5000 (+/- 7,5 %)
•
•
•
Electronic protection against locking or overload.
3
Max. flow rate
m /h
80
Electronic reverse polarity protection. Fan starts only with correct
polarity.
Max. flow rate
CFM
47
Noise free air
dB(A)
48
Alarm output signal type /19; high
on fail; for details please refer to
alarm specification attached.
Noise in optimum operating range
bels
6.2
mA
270
Power consumtion
W
6.4
Permanent ambient temperature
°C
-20 ... +65
Service life (65 °C)
h
37.500
Service life (40 °C)
h
70.000
Current consumption
Electrical connection via 3 leads
AWG 22, TR64, 310mm long,
stripped and tinned ends (red =
+24V; black = GND; yellow =
alarm)
at max. voltage
Patents granted or applied for.
Approvals
UL, VDE, CSA
Fan housing / impeller
PBTP / PA 6.6
Bearing system
Mass
kg
All data are mean values at nominal conditions.
0
5
10
15
Ball bearings
0,170
Subject to change without notice
x10-3m 3/s
140
Druckerhöhung
pf
Pa
100
80
60
40
20
0
0
10
20
30
40
50
Volumenstrom V
ebm-papst St. Georgen GmbH & Co KG
60
3
m /h 80
8314_19H.doc
24.11.2009
Alarm Signal Output:
U (+)
ISource
U
a
ISink
U
R
ba
a
GND
U (+)
Ua
Uba
GND
Ra
=
=
=
=
=
Supply Voltage (+)
Alarm Signal
Alarm Supply Voltage
Ground (-)
External Pull up-Resistor
n > nG
Ra =
n> nG
Ub a - Ua L
Isin k
n> nG
n
U/min
n< nG
blockiert
n= 0 U/m in
t
U(+ )
Volt
t
Ua
Volt
t
Technical Data
Designation
Alarm Circuit
This fan is equipped with an integrated
alarm circuit producing a continuous
output signal Ua for monitoring fan
speed. At proper operation in the nominal voltage range the alarm output is a
„low“ level.
When speed decreases below limit
speed nG = 1500rpm (+/-100rpm), e.g.
by high friction torque, locked rotor
condition, or low operating voltage, a
„high“ level output will occur.
When speed recovers, the alarm signal
goes back to „low“, i.e. alarm is nonlatched.
Test condition
Symbol
Value
Alarm output voltage
Uba max
60 V DC
Max. sink current
Isink max
20 mA
Ua L
≤ 0,3 V
Ua H
≤ 60 V
Ua = 60 V
Isink
max. 15µA
at start up only
t2
< 15 s +/- 1s
Signal rise and fall time
Ua
tr, tf
min.0,5V/µs
(Stand TTL)
Alarm trip speed
nG
Output voltage “Low”
nnG
Leakage current
n>nG
Alarm delay time
1500pm
+/- 100rpm
trÎLow-High
ebm-papst St. Georgen GmbH & Co KG
tf Î High-Low
Alarm Signal suppressed at start-up
8314_19H.doc
24.11.2009