Product Data Sheet 8506 VW-691
The engineer's choice
Product Data Sheet 8506 VW-691
8506 VW-691
INDEX
1
General ...................................................................................................................................................................... 3
2
Mechanics ................................................................................................................................................................. 3
2.1
2.2
3
Operating Data ......................................................................................................................................................... 5
3.1
3.2
3.3
3.4
3.5
4
GENERAL ............................................................................................................................................................ 8
CLIMATIC REQUIREMENTS*) .................................................................................................................................. 8
Safety ........................................................................................................................................................................ 9
5.1
5.2
6
ELECTRICAL OPERATING DATA ............................................................................................................................. 5
OPERATING DATA - ELECTRICAL INTERFACE -OUTPUT ........................................................................................... 6
ELECTRICAL FEATURES........................................................................................................................................ 6
AERODYNAMIC..................................................................................................................................................... 6
SOUND DATA ....................................................................................................................................................... 7
Environment ............................................................................................................................................................. 8
4.1
4.2
5
GENERAL ............................................................................................................................................................ 3
CONNECTIONS ..................................................................................................................................................... 4
ELECTRICAL SAFETY ............................................................................................................................................ 9
APPROVAL TESTS ................................................................................................................................................ 9
Reliability .................................................................................................................................................................. 9
6.1
GENERAL ............................................................................................................................................................ 9
11/05/2014
page 2 of 10
Product Data Sheet 8506 VW-691
1
General
Fan type
Rotational direction looking at rotor
Airflow direction
Bearing system
Mounting position
Balancing grade
2
Mechanics
2.1
General
Width
Height
Depth
Diameter
Weight
Housing material
Impeller material
Max. torque when mounted across both mounting
flanges
Screw size
Fan
clockwise
Air outlet over struts
Ball bearing
any
2,5
80,0 mm
80,0 mm
38,0 mm
0,0 mm
0,490 kg
Metal
Metal
wire outlet corner: 50 Ncm
remaining corners: 120 Ncm
ISO 4762 - M4 degreased, without an additional
brace and without washer
11/05/2014
page 3 of 10
Product Data Sheet 8506 VW-691
2.2
Connections
Electrical connection
Length of lead wire
Wires
L = 1.530,0 mm
+- 20,0 mm
Tolerance
see drawing
Length of tube
Tolerance
Wire gauge (AWG)
Insulation diameter
Plug
Contact
Wire 1
Wire 2
18
2,06 mm
see drawing
see drawing
Colour
black
white
Operation
L
N
11/05/2014
page 4 of 10
Product Data Sheet 8506 VW-691
3
Operating Data
3.1
Electrical Operating Data
Measurement
conditions:
Normal air density = 1,2 kg/m3; Temperature 23°C +/- 3°C; Motor axis horizontal;warm-up
time before measuring 5 minutes (unless otherwise specified).
In the intake and outlet area should not be any solid obstruction within 0,5 m.
∆p = 0: corresp. to free air flow (see section 3.4)
I:
corresp. to RMS line current
Features
Condition
Symbol
Frequency
∆p = 0
f
Nominal voltage
∆p = 0
UN
∆p = 0
P
Values
50 Hz
115,0 V
+- 10,0 %
60 Hz
115,0 V
+- 10,0 %
12,0 W
11,0 W
+ 5,0 %
- 10,0 %
2.800 1/min
+- 3,0 %
+ 5,0 %
- 10,0 %
3.300 1/min
+- 3,0 %
Tolerance
Power consumption
Tolerance
Speed
Tolerance
∆p = 0
n
11/05/2014
page 5 of 10
Product Data Sheet 8506 VW-691
3.2
Operating Data - Electrical Interface -Output
Tacho type
3.3
None
Electrical Features
Locked rotor protection
Locked rotor current at Un
3.4
Impedance
Aerodynamic
Measurement
conditions:
Measured with a double chamber intake rig acc. to DIN EN ISO 5801.
Normal air density = 1,2 kg/m3; Temperature 23°C +/- 3°C;
In the intake and outlet area should not be any solid obstruction within 0,5 m.
The information is only valid under the specified test conditions and may be changed by the
installation conditions. If there are deviations from the standard test conditions, the
characteristic values must be checked under the installed conditions.
a.) Operation condition:
2.800 1/min at free air flow
Max. free-air flow (∆p = 0 / = max.)
Max. static pressure (∆p = max. / =0)
Frequency: 50 Hz
44,0 m3/h
43 Pa
b.) Operation condition:
3.300 1/min at free air flow
Max. free-air flow (∆p = 0 / = max.)
Max. static pressure (∆p = max. / =0)
Frequency: 60 Hz
53,0 m3/h
60 Pa
11/05/2014
page 6 of 10
Product Data Sheet 8506 VW-691
3.5
Sound Data
Measurement
conditions:
Sound pressure level: 1 Meter distance between microphone and the air intake.
Sound power level: Acc. to DIN 45635 part 38 (ISO 10302)
Measured in a semianchoic chamber with a background noise level of Lp(A) < 5 dB(A)
For further measurement conditions see section 3.4
a.) Operation condition:
2.800 1/min at free air flow
Optimal operating point
Sound power level at the optimal operating
point
Sound pressure level at free air flow,
measured in rubber bands
b.) Operation condition:
3.300 1/min at free air flow
Frequency: 50 Hz
38,0 m3/h @ 7 Pa
4,8 bel(A)
31,0 dB(A)
Frequency: 60 Hz
Optimal operating point
46,0 m3/h @ 10 Pa
Sound power level at the optimal operating
point
Sound pressure level at free air flow,
measured in rubber bands
5,2 bel(A)
35,0 dB(A)
11/05/2014
page 7 of 10
Product Data Sheet 8506 VW-691
4
Environment
4.1
General
Min. permitted ambient temperature TU min.
Max. permitted ambient temperature TU max.
Min. permitted storage temperature TL min.
Max. permitted storage temperature TL max.
4.2
-40 °C / 50 Hz
-40 °C / 60 Hz
90 °C / 50 Hz
95 °C / 60 Hz
-40 °C
100 °C
Climatic requirements*)
Humidity requirements
Water exposure
Radiation exposure
Dust requirements
Salt fog requirements
Harmful gas requirements
humid heat, constant; according to DIN EN 60068-278, 14 days
None
None
None
None
None
*) Permittet application area:
The product is intended for use in sheltered rooms with controlled temperature and controlled humidity. Directly
exposure to water must be avoided.
Pollution degree 1 (according DIN EN 60664-1)
There is either no pollution or it occurs only dry, non-conductive pollution. The pollution has no negative impact.
11/05/2014
page 8 of 10
Product Data Sheet 8506 VW-691
5
Safety
5.1
Electrical Safety
Dielectric strength
DIN EN 60950 (VDE 0805) and DIN EN 60335 (VDE
0700)
A.) Type test
Measuring conditions: After 48h of storage at 95%
R.H. and 25°C.
No arcing or breakdown is allowed!
All connections together to ground.
B.) Routine test
Measuring conditions: At indoor climate.
No arcing or breakdown is allowed!
All connections together to ground.
Isolation resistance
Measuring conditions: After 48h of storage at 95%
R.H. and 25°C measured with U=500 VDC for 1 min.
clearance / creepage distance
Protection class
5.2
1000 VAC / 1 Min.
1500 VAC / 1 Sec.
RI > 50 MOhm
2,0 mm / 1,1 mm
I
Approval Tests
CE
UL
Yes
Yes / UL507, Electric Fans
Yes / Approval acc. to EN 60950 (VDE 0805) - Information
technology equipment
Yes / C22.2 No. 113 Fans and Ventilators
Yes / GB 12350 Safety Requirements for small Power Motors
VDE
CSA
CCC
The approval tests are observed to:
U approval max.: 115 V / f: 60 Hz @ TU approval max.: 95 °C
6
Reliability
6.1
General
Life expectancy L10 at TU = 40 °C
Life expectancy L10 at TU max.
52.500 h / 50 Hz
55.000 h / 60 Hz
15.000 h / 50 Hz
15.000 h / 60 Hz
11/05/2014
page 9 of 10
很抱歉,暂时无法提供与“8506VW-691”相匹配的价格&库存,您可以联系我们找货
免费人工找货- 国内价格 香港价格
- 1+443.795451+53.03074
- 10+423.8087210+50.64246
- 国内价格
- 2+356.62412
- 50+336.14196