product specification 8830 VW
8830 VW
Customer specification: No
Version: 1.0
Created: 12.01.2012
INDEX
1
General ....................................................................................................................................................................... 2
2
Mechanics ................................................................................................................................................................... 2
2.1
2.2
3
Operating Data............................................................................................................................................................ 3
3.1
3.2
3.3
3.4
3.5
4
GENERAL ............................................................................................................................................................. 6
CLIMATIC REQUIREMENTS*)................................................................................................................................... 6
Safety .......................................................................................................................................................................... 6
5.1
5.2
6
ELECTRICAL OPERATING DATA .............................................................................................................................. 3
OPERATING DATA - ELECTRICAL INTERFACE -OUTPUT ............................................................................................. 3
ELECTRICAL FEATURES ......................................................................................................................................... 4
AERODYNAMIC ..................................................................................................................................................... 4
SOUND DATA ....................................................................................................................................................... 5
Environment ............................................................................................................................................................... 6
4.1
4.2
5
GENERAL ............................................................................................................................................................. 2
CONNECTIONS ...................................................................................................................................................... 2
ELECTRICAL SAFETY ............................................................................................................................................. 6
APPROVAL TESTS .................................................................................................................................................. 7
Reliability .................................................................................................................................................................... 7
6.1
GENERAL ............................................................................................................................................................. 7
Special features according to QMH 2-5.4.7 and company standard 1-23.00 have the following definitions:
"A" : Product features or process parameters which influence the safety of a product or the compliance of legal
requirements. (Must not necessary verified and documented 100%. Standards and legal requirements must be
considered.)
"FK" : Product features or process parameters which influence the fit and function of a product or which have to be
controlled or documented for some other reasons (e.g. Customer requirements).
page 1 of 7
product specification 8830 VW
1
General
Fan type
Rotational direction looking at rotor
Airflow direction
Bearing system
Mounting position
Tolerance
Balancing grade
2
Fan
clockwise
Air outlet over struts
Sleeve bearing
any
FK
FK
2,5
FK
Mechanics
2.1
General
Width
Height
Depth
Weight
Housing material
Impeller material
Max. torque when mounted across both mounting
flanges
Screw size
2.2
Connections
Electrical connection
Length of lead wire
80,0 mm
80,0 mm
38,0 mm
0,490 kg
Metal
Metal
wire outlet corner: 50 Ncm
remaining corners: 120 Ncm
ISO 4762 - M4 degreased, without an additional
brace and without washer
Wires
310,0 mm
+- 10,0 mm
Tolerance
see drawing
Length of tube
Tolerance
Wire gauge (AWG)
Insulation diameter
Wire 1
Wire 2
18
2,06 mm
Colour
black
black
Operation
L
N
page 2 of 7
product specification 8830 VW
3
Operating Data
3.1
Electrical Operating Data
Measurement
conditions:
Normal air density = 1,2 kg/m3; Temperature 23°C +/- 3°C; Motor axis horizontal;warm-up
time before measuring 5 minutes (unless otherwise specified).
In the intake and outlet area should not be any solid obstruction within 0,5 m.
∆p = 0: corresp. to free air flow (see section 3.4)
I:
corresp. to RMS line current
Features
Frequency
Nominal voltage
Condition
∆p = 0
Symbol
f
∆p = 0
UN
∆p = 0
P
Tolerance
Power consumption
Tolerance
Current consumption
Tolerance
∆p = 0
∆p = 0
60 Hz
115,0 V
+- 10,0 %
9,0 W
8,0 W
+ 5,0 %
- 10,0 %
100 mA *)
+ 5,0 %
- 10,0 %
100 mA *)
+ 5,0 %
- 10,0 %
1.750 1/min *)
+- 10,0 %
+ 5,0 %
- 10,0 %
1.950 1/min *)
+- 10,0 %
I
Speed
Tolerance
Values
50 Hz
115,0 V
+- 10,0 %
n
*) Attention: Marked values are "FK" features
3.2
Operating Data - Electrical Interface -Output
Tacho type
None
page 3 of 7
product specification 8830 VW
3.3
Electrical Features
Locked rotor protection
Locked rotor current at Un
3.4
Impedance
A
Aerodynamic
Measurement
conditions:
Measured with a double chamber intake rig acc. to DIN EN ISO 5801.
Normal air density = 1,2 kg/m3; Temperature 23°C +/- 3°C;
In the intake and outlet area should not be any solid obstruction within 0,5 m.
a.) Operation condition:
1.750 1/min at free air flow
Max. free-air flow (∆p = 0 / = max.)
Max. static pressure (∆p = max. / =0)
b.) Operation condition:
1.950 1/min at free air flow
Max. free-air flow (∆p = 0 / = max.)
Max. static pressure (∆p = max. / =0)
Frequency: 50 Hz
27,0 m3/h
16 Pa
FK
FK
Frequency: 60 Hz
31,0 m3/h
18 Pa
FK
FK
page 4 of 7
product specification 8830 VW
3.5
Sound Data
Measurement
conditions:
Sound pressure level: 1 Meter distance between microphone and the air intake.
Sound power level: Acc. to DIN 45635 part 38 (ISO 10302)
Measured in a semianchoic chamber with a background noise level of Lp(A) < 5 dB(A)
For further measurement conditions see section 3.4
a.) Operation condition:
1.750 1/min at free air flow
Frequency: 50 Hz
Optimal operating point
27,0 m3/h @ 0 Pa
Sound power level at the optimal operating
point
Sound pressure level at free air flow,
measured in rubber bands
3,7 bel(A)
b.) Operation condition:
1.950 1/min at free air flow
16,0 dB(A)
Frequency: 60 Hz
Optimal operating point
31,0 m3/h @ 0 Pa
Sound power level at the optimal operating
point
Sound pressure level at free air flow,
measured in rubber bands
3,8 bel(A)
19,0 dB(A)
page 5 of 7
product specification 8830 VW
4
Environment
4.1
General
Min. permitted ambient temperature TU min.
Max. permitted ambient temperature TU max.
Min. permitted storage temperature TL min.
Max. permitted storage temperature TL max.
4.2
-10 °C / 50 Hz
-10 °C / 60 Hz
80 °C / 50 Hz
80 °C / 60 Hz
-40 °C
80 °C
Climatic requirements*)
Humidity requirements
humid heat, constant; according to DIN EN 60068-278, 14 days
None
None
None
None
None
Water exposure
Radiation exposure
Dust requirements
Salt fog requirements
Harmful gas requirements
*) Permittet application area:
The product is intended for use in sheltered rooms with controlled temperature and controlled humidity. Directly
exposure to water must be avoided.
Pollution degree 1 (according DIN EN 60664-1)
There is either no pollution or it occurs only dry, non-conductive pollution. The pollution has no negative impact.Safety
5.1
Electrical Safety
Dielectric strength
DIN EN 60950 (VDE 0805) and DIN EN 60335 (VDE
0700)
A.) Type test
Measuring conditions: After 48h of storage at 95%
R.H. and 25°C.
No arcing or breakdown is allowed!
All connections together to ground.
B.) Routine test
Measuring conditions: At indoor climate.
No arcing or breakdown is allowed!
All connections together to ground.
Isolation resistance
Measuring conditions: After 48h of storage at 95%
R.H. and 25°C measured with U=500 VDC for 1 min.
Air and leakage distances
Protection class
1000 VAC / 1 Min.
1500 VAC / 1 Sec.
A
RI > 50 MOhm
2,0 mm / 1,1 mm
I
page 6 of 7
product specification 8830 VW
5.2
Approval Tests
CE
UL
Yes
Yes / UL507, Electric Fans
Yes / Approval acc. to EN 60950 (VDE 0805) - Information
technology equipment
Yes / C22.2 No. 113-M1984 Fans and Ventilators
Yes / GB 12350 Safety Requirements for small Power Motors
VDE
CSA
CCC
The approval tests are observed to:
U approval max.: 115 V / f: 50 and 60 Hz @ TU approval max.: 80 °C
6
Reliability
6.1
General
Life expectancy L10 at TU = 40 °C
Life expectancy L10 at TU max.
Life expectancy L10 acc. to IPC 9591 at TU = 40 °C
60.000 h / 50 Hz
62.500 h / 60 Hz
25.000 h / 50 Hz
25.000 h / 60 Hz
/ 50 Hz
/ 60 Hz
page 7 of 7