0
登录后你可以
  • 下载海量资料
  • 学习在线课程
  • 观看技术视频
  • 写文章/发帖/加入社区
会员中心
创作中心
发布
  • 发文章

  • 发资料

  • 发帖

  • 提问

  • 发视频

创作活动
A2E200-AH86-75

A2E200-AH86-75

  • 厂商:

    EBMPAPST(依必安派特)

  • 封装:

    插件

  • 描述:

    风扇 管轴式 115VAC 圆形 - 197mm 直径 滚珠 4 根引线 - QC 插座(2),环形端子(1),引线(1)

  • 数据手册
  • 价格&库存
A2E200-AH86-75 数据手册
A2E200-AH86-75 Operating instructions ebm-papst Mulfingen GmbH & Co. KG Bachmühle 2 D-74673 Mulfingen Phone +49 (0) 7938 81-0 Fax +49 (0) 7938 81-110 info1@de.ebmpapst.com www.ebmpapst.com 1. SAFETY REGULATIONS AND INFORMATION Read these operating instructions carefully before starting work on the device. Observe the following warnings to prevent malfunctions or danger to persons. These operating instructions are to be regarded as part of the device. The device is only to be sold or passed on together with the operating instructions. These operating instructions may be duplicated and distributed to inform about potential dangers and their prevention. Translation of the original operating instructions CONTENTS 1. SAFETY REGULATIONS AND INFORMATION 1 1.1 Hazard levels for warnings 1.2 Staff qualifications 1.3 Basic safety rules 1.4 Voltage 1.5 Safety and protective features 1.6 Mechanical movement 1.7 Emissions 1.8 Hot surface 1.9 Transport 1.10 Storage 1 1 1 1 2 2 2 2 2 2 2. INTENDED USE 3 3. TECHNICAL DATA 4 3.1 Product drawing 3.2 Nominal data 3.3 Technical description 3.4 Mounting data 3.5 Transport and storage conditions 4 5 5 5 5 4. CONNECTION AND STARTUP 6 4.1 Mechanical connection 4.2 Electrical connection 4.3 Connecting the cables 4.4 Connection diagram 4.5 Checking connections 4.6 Switching on the device 4.7 Switching off the device 6 6 7 8 9 9 9 1.2 Staff qualifications 5. MAINTENANCE, MALFUNCTIONS, POSSIBLE CAUSES AND REMEDIES 9 1.3 Basic safety rules 5.1 Cleaning 5.2 Safety inspection 5.3 Disposal 10 10 10 1.1 Hazard levels for warnings These operating instructions use the following hazard levels to indicate potentially hazardous situations and important safety regulations: DANGER Indicates an imminently hazardous situation which will result in death or serious injury if the specified actions are not taken. Compliance with the instructions is imperative. WARNING Indicates a potentially hazardous situation which can result in death or serious injury if the specified actions are not taken. Exercise extreme caution while working. CAUTION Indicates a potentially hazardous situation which can result in minor or moderate injury or damage to property if the specified actions are not taken. NOTE A potentially harmful situation can occur and, if not avoided, can lead to property damage. The device may only be transported, unpacked, installed, operated, maintained and otherwise used by suitably qualified, trained and authorized technical staff. Only authorized specialists are permitted to install the device, to carry out a test run and to perform work on the electrical installation. The safety hazards associated with the device must be assessed again following installation in the final product. The locally applicable industrial safety regulations are always to be observed when working on the device. Keep the workplace clean and tidy. Untidiness in the work area increases the risk of accidents. Note the following when working on the device: ; Do not perform any modifications, additions or conversions on the device without the approval of ebm-papst. 1.4 Voltage ; Check the device's electrical equipment at regular intervals; see Chapter 5.2 Safety inspection. ; Replace loose connections and defective cables immediately. DANGER Electrically charged device Risk of electric shock → When working on an electrically charged device, stand on a rubber mat. Item no. 16023-5-9970 · ENU · Change 202174 · Approved 2018-12-27 · Page 1 / 11 ebm-papst Mulfingen GmbH & Co. KG · Bachmühle 2 · D-74673 Mulfingen · Phone +49 (0) 7938 81-0 · Fax +49 (0) 7938 81-110 · info1@de.ebmpapst.com · www.ebmpapst.com A2E200-AH86-75 Operating instructions CAUTION Electric charge on capacitor after device is switched off Electric shock, risk of injury → Discharge the capacitors before working on the device. WARNING Live terminals and connections even with device switched off Electric shock → Wait five minutes after disconnecting the voltage at all poles before opening the device. CAUTION In the event of a fault, the rotor and the impeller will be energized The rotor and the impeller have basic insulation. → Do not touch the rotor and impeller once installed. CAUTION The motor restarts automatically when operating voltage is applied, e.g. after a power failure. Risk of injury → Keep out of the device's danger zone. → When working on the device, switch off the line voltage and ensure that it cannot be switched back on. → Wait until the device comes to a stop. 1.5 Safety and protective features DANGER Guard missing and guard not functioning Without a guard, hands may become caught up in the device during operation for example, resulting in serious injury. Loose parts or items of clothing could be drawn in. → The device is a built-in component. As the owner, you are responsible for ensuring that the device is adequately safeguarded.# Operate the device only with a fixed protective device and guard grill. → Stop the device immediately if a protective device is found to be missing or ineffective. 1.7 Emissions WARNING Depending on the installation and operating conditions, the sound pressure level may exceed 70 dB(A). Risk of noise-induced hearing loss → Take appropriate technical safety measures. → Protect operating personnel with appropriate safety equipment such as hearing protection. → Also observe the requirements of local agencies. 1.8 Hot surface CAUTION High temperature on motor housing Risk of burns → Ensure sufficient protection against accidental contact. 1.9 Transport NOTE Transporting the device → Transport the device in its original packaging only. → Secure the device so it cannot slip, e.g. by using a lashing strip. 1.10 Storage ; Store the device, partially or fully assembled, in a dry place, protected against the weather and free from vibration, in the original packaging in a clean environment. ; Protect the device against environmental effects and dirt until final installation. ; We recommend storing the device for no longer than one year in order to guarantee trouble-free operation and the longest possible service life. ; Even devices explicitly intended for outdoor use are to be stored as described prior to commissioning. ; Maintain the storage temperature, see Chapter 3.5 Transport and storage conditions. Translation of the original operating instructions 1.6 Mechanical movement DANGER Rotating device Risk of injury to body parts coming into contact with the rotor or the impeller. → Secure the device against accidental contact. → Before working on the system/machine, wait until all parts have come to a standstill. WARNING Rotating device Long hair and dangling items of clothing, jewelry and the like can become entangled and be pulled into the device. Injuries can result. → Do not wear any loose-fitting or dangling clothing or jewelry while working on rotating parts. → Protect long hair with a cap. Item no. 16023-5-9970 · ENU · Change 202174 · Approved 2018-12-27 · Page 2 / 11 ebm-papst Mulfingen GmbH & Co. KG · Bachmühle 2 · D-74673 Mulfingen · Phone +49 (0) 7938 81-0 · Fax +49 (0) 7938 81-110 · info1@de.ebmpapst.com · www.ebmpapst.com A2E200-AH86-75 Operating instructions 2. INTENDED USE The device is exclusively designed as a built-in device for conveying air according to its technical data. Any other usage above and beyond this does not conform with the intended purpose and constitutes misuse of the device. Customer equipment must be capable of withstanding the mechanical and thermal stresses that can arise from this product. This applies for the entire service life of the equipment in which this product is installed. Intended use also includes ● Using the device solely outside of the EU. ● Conveying air at an ambient air pressure between 800 mbar and 1050 mbar. ● Using the device within the permitted ambient temperature range; see Chapter 3.5 Transport and storage conditions and Chapter 3.2 Nominal data. ● Operating the device with all protective devices. ● Following the operating instructions. Improper use Translation of the original operating instructions In particular, operating the device in the following ways is prohibited and could be hazardous: ● Operating the device in an unbalanced state, e.g. due to dirt deposits or ice formation. ● Resonant operation, operation with severe vibration. This also includes vibration transmitted to the fan from the customer installation. ● Operation in medical equipment with a life-sustaining or life-support function. ● Conveying solids in the flow medium. ● Painting the device ● Connections (e.g. screws) coming loose during operation. ● Conveying air that contains abrasive particles. ● Conveying highly corrosive air, e.g. salt spray. Exception: devices designed for salt spray and correspondingly protected. ● Conveying air with high dust content, e.g. suctioning off sawdust. ● Operating the device close to flammable materials or components. ● Operating the device in an explosive atmosphere. ● Using the device as a safety component or to perform safety-related functions. ● Operation with completely or partially disassembled or manipulated protective devices. ● In addition, all applications not listed among the intended uses. Item no. 16023-5-9970 · ENU · Change 202174 · Approved 2018-12-27 · Page 3 / 11 ebm-papst Mulfingen GmbH & Co. KG · Bachmühle 2 · D-74673 Mulfingen · Phone +49 (0) 7938 81-0 · Fax +49 (0) 7938 81-110 · info1@de.ebmpapst.com · www.ebmpapst.com A2E200-AH86-75 Operating instructions 3. TECHNICAL DATA 3.1 Product drawing All dimensions in mm. Airflow direction "V" Max. clearance for screw 5 mm Cable PFA AWG18, 1x lead tip, 2x fully insulated flat push-on receptacle, 1x insulated ring terminal Translation of the original operating instructions 1 2 3 Item no. 16023-5-9970 · ENU · Change 202174 · Approved 2018-12-27 · Page 4 / 11 ebm-papst Mulfingen GmbH & Co. KG · Bachmühle 2 · D-74673 Mulfingen · Phone +49 (0) 7938 81-0 · Fax +49 (0) 7938 81-110 · info1@de.ebmpapst.com · www.ebmpapst.com Operating instructions A2E200-AH86-75 3.2 Nominal data Motor M2E068-BF Phase Nominal voltage / VAC Frequency / Hz 1~ 115 60 1~ 115 60 Method of obtaining data Valid for approval/ standard Speed (rpm) / min-1 Power consumption / W Current draw / A Capacitor / µF Capacitor voltage / VDB Max. back pressure / Pa Min. ambient temperature / °C Max. ambient temperature / °C fa fa CE UL 2700 81 0.7 5 220 90 -25 2700 85 0.72 5 220 90 -25 70 70 Subject to change 3.3 Technical description Translation of the original operating instructions Insulation class Moisture (F) / Environmental (H) protection class Installation position Condensation drainage holes Mode Motor bearing Touch current according to IEC 60990 (measuring circuit Fig. 4, TN system) Motor protection with cable Protection class Conformity with standards Approval ; Use the device in accordance with its degree of protection. Information on surface quality The surfaces of the products conform to the generally applicable industrial standard. The surface quality may change during the production period. This has no effect on strength, dimensional stability and dimensional accuracy. The color pigments in the paints used perceptibly react to UV light over the course of time. This does not however in any way affect the technical properties of the products. The product is to be protected against UV radiation to prevent the formation of patches and fading. Changes in color are not a reason for complaint and are not covered by the warranty. 3.4 Mounting data Strength class of screws 8.8 For screw clearance, see Chapter 3.1 Product drawing ml = Max. load · me = Max. efficiency · fa = Free air cs = Customer specification · ce = Customer equipment Weight Size Motor size Rotor surface Blade material Number of blades Airflow direction Direction of rotation Degree of protection With regard to cyclic speed loads, note that the rotating parts of the device are designed for a maximum of one million load cycles. If you have special questions, consult ebm-papst for support. 1.32 kg 200 mm 68 Painted black Sheet steel, painted black 9 V Counterclockwise, viewed toward rotor IP44; installation- and position-dependent as per EN 60034-5 "B" H1 ; Secure the screws against unintentional loosening (e.g. use selflocking screws). Any further mounting data required can be taken from the product drawing or Section Chapter 4.1 Mechanical connection. 3.5 Transport and storage conditions Max. permitted ambient temp. for motor (transport/ storage) Min. permitted ambient temp. for motor (transport/ storage) + 80 °C - 40 °C Shaft horizontal or rotor on top; rotor on bottom on request On rotor side S1 Ball bearing < 0.75 mA Thermal overload protector (TOP) internally connected Variable I (with customer connection of protective earth) EN 60335-1; CE UL 1004-3; CSA C22.2 No. 77 Item no. 16023-5-9970 · ENU · Change 202174 · Approved 2018-12-27 · Page 5 / 11 ebm-papst Mulfingen GmbH & Co. KG · Bachmühle 2 · D-74673 Mulfingen · Phone +49 (0) 7938 81-0 · Fax +49 (0) 7938 81-110 · info1@de.ebmpapst.com · www.ebmpapst.com A2E200-AH86-75 Operating instructions 4. CONNECTION AND STARTUP 4.1 Mechanical connection CAUTION Cutting and crushing hazard when removing fan from packaging → Carefully remove the device from its packaging, grasping it by only the blades near the hub. Strictly avoid shocks. → Wear safety shoes and cut-resistant safety gloves. NOTE Damage to the device from vibration Bearing damage, shorter service life → The fan must not be subjected to force or excessive vibration from sections of the installation. → If the fan is connected to air ducts, the connection should be isolated from vibration, e.g. using compensators or similar elements. → Ensure stress-free attachment of the fan to the substructure. ; Check the device for transport damage. Damaged devices are not to be installed. ; Install the undamaged device in accordance with your application. CAUTION Possible damage to the device If the device slips during installation, serious damage can result. → Ensure that the device is securely positioned at its place of installation until all fastening screws have been tightened. ● The fan must not be strained on fastening. 4.2 Electrical connection DANGER Voltage on the device Electric shock → Always connect a protective earth first. Translation of the original operating instructions → Check the protective earth. DANGER Faulty insulation Risk of fatal injury from electric shock → Use only cables that meet the specified installation regulations for voltage, current, insulation material, capacity, etc. → Route cables so that they cannot be touched by any rotating parts. CAUTION Voltage The fan is a built-in component and has no disconnecting switch. → Only connect the fan to circuits that can be switched off with an all-pole disconnection switch. → When working on the fan, secure the system/machine in which the fan is installed so as to prevent it from being switched back on. NOTE Water ingress into wires or cables Water ingress at the customer end of the cable can damage the device. → Make sure the end of the cable is connected in a dry environment. Only connect the device to circuits that can be switched off with an all-pole disconnection switch. 4.2.1 Requirements ; Check whether the information on the nameplate matches the connection data. ; If the motor run capacitor was not installed by ebm-papst, check whether the information on the motor run capacitor matches the information on the nameplate. ; Before connecting the device, make sure the power supply matches the device voltage. ; Only use cables designed for the current level indicated on the nameplate. For determining the cross-section, note the sizing criteria according to EN 61800-5-1. The protective earth must have a cross-section equal to or greater than that of the phase conductor. We recommend the use of 105 °C cables. Ensure that the minimum cable cross-section is at least AWG 26 / 0.13 mm². Protective earth contact resistance according to EN 60335 Compliance with the resistance specifications according to EN 60335 for the protective earth connection circuit must be verified in the end application. Depending on the installation situation, it may be necessary to connect an additional protective earth conductor by way of the extra protective earth terminal provided on the device. 4.2.2 Voltage control NOTE Current overshoots may occur if speed control is implemented by transformers or electronic voltage regulators (e.g. phase control). Depending on the type of installation of the device, noise and vibration may also occur in the case of phase control. Vibration can lead to bearing damage and thus premature failure. Heating-up of the motor when using voltage control must be checked by the customer following installation in the end device. 4.2.3 Variable frequency drive Please use a variable frequency drive only after consultation with ebmpapst. For operation with variable frequency drives, install sinusoidal filters that work on all poles (phase-phase and phase-ground) between the drive and the motor. During operation with variable frequency drives, an all-pole sine filter protects the motor against high-voltage transients that can destroy the coil insulation system, and against harmful bearing currents. Heating-up of the motor when using a variable frequency drive must be checked by the customer following installation in the end device. Item no. 16023-5-9970 · ENU · Change 202174 · Approved 2018-12-27 · Page 6 / 11 ebm-papst Mulfingen GmbH & Co. KG · Bachmühle 2 · D-74673 Mulfingen · Phone +49 (0) 7938 81-0 · Fax +49 (0) 7938 81-110 · info1@de.ebmpapst.com · www.ebmpapst.com A2E200-AH86-75 Operating instructions 4.3 Connecting the cables The device has external leads. ; First connect the "PE" (protective earth). ● Connect the cables according to your application. When doing so, observe Chapter 4.4 Connection diagram. 4.3.1 Cable routing Water must be prevented from reaching the cable exit along the cable. NOTE Damage caused by moisture penetration. Moisture can penetrate into the terminal box if water is constantly present at the cable glands. → To prevent the constant accumulation of water at the cable glands, the cable should be routed in a U-shaped loop wherever possible. → If this is not possible, a drip edge can be produced by fitting a cable tie directly in front of the cable gland for example. Fans installed upright Translation of the original operating instructions Fig. 1: Cable routing for fans installed upright. The cables must always be routed downward. Item no. 16023-5-9970 · ENU · Change 202174 · Approved 2018-12-27 · Page 7 / 11 ebm-papst Mulfingen GmbH & Co. KG · Bachmühle 2 · D-74673 Mulfingen · Phone +49 (0) 7938 81-0 · Fax +49 (0) 7938 81-110 · info1@de.ebmpapst.com · www.ebmpapst.com A2E200-AH86-75 Operating instructions 4.4 Connection diagram blue brown black green/yellow Translation of the original operating instructions U1 Z U2 PE Item no. 16023-5-9970 · ENU · Change 202174 · Approved 2018-12-27 · Page 8 / 11 ebm-papst Mulfingen GmbH & Co. KG · Bachmühle 2 · D-74673 Mulfingen · Phone +49 (0) 7938 81-0 · Fax +49 (0) 7938 81-110 · info1@de.ebmpapst.com · www.ebmpapst.com A2E200-AH86-75 Operating instructions 4.5 Checking connections ; Ensure isolation from supply (all phases). ; Make sure a restart is impossible ; Check the cables for proper fit. 4.6 Switching on the device The device may only be switched on if it has been installed properly and in accordance with its intended use, including the required safety mechanisms and professional electrical hookup. This also applies for devices which have already been equipped with plugs and terminals or similar connectors by the customer. WARNING Hot motor housing Risk of fire → Ensure that no combustible or flammable materials are located close to the fan. ; Before switching on, check the device for visible external damage and make sure the protective devices are functional. ; Check the fan's air flow paths for foreign matter and remove any foreign matter found. ; Apply the nominal supply voltage. NOTE Damage to the device from vibration Bearing damage, shorter service life → Low-vibration operation of the fan must be ensured over the entire speed control range. → Severe vibration can arise for instance from inexpert handling, transportation damage and resultant imbalance or be caused by component or structural resonance. 5. MAINTENANCE, MALFUNCTIONS, POSSIBLE CAUSES AND REMEDIES Do not perform any repairs on your device. Send the device to ebmpapst for repair or replacement. WARNING Live terminals and connections even with device switched off Electric shock → Wait five minutes after disconnecting the voltage at all poles before opening the device. CAUTION Electric charge on capacitor after device is switched off Electric shock, risk of injury → Discharge the capacitors before working on the device. CAUTION The motor restarts automatically when operating voltage is applied, e.g. after a power failure. Risk of injury → Keep out of the device's danger zone. → When working on the device, switch off the line voltage and ensure that it cannot be switched back on. → Wait until the device comes to a stop. If the device is out of use for some time, e.g. when in storage, we recommend switching it on for at least two hours to allow any condensation to evaporate and to move the bearings. Malfunction/fault Impeller not running smoothly → Speed ranges with excessively high vibration levels and possibly resonant frequencies must be determined in the course of fan commissioning. → Either run through the resonant range as quickly as possible with speed control or find another remedy. Translation of the original operating instructions → Operation with excessively high vibration levels can lead to premature failure. Motor not turning 4.7 Switching off the device ; Disconnect the device from the power supply at the supply line's main switch. ; When disconnecting, be sure to disconnect the ground connection last. Motor overtemperature Possible cause Imbalance in rotating parts Possible remedy Clean the device; replace it if imbalance persists after cleaning. Make sure no weight clips are removed during cleaning. Mechanical blockage Switch off, isolate from supply and remove mechanical blockage. Line voltage faulty Check line voltage, restore power supply. Faulty connection Isolate from supply, correct connection; see connection diagram. Thermal overload Allow motor to cool protector activated off, locate and rectify cause of error, release restart lockout if necessary Impermissible point of Check point of operation operation Ambient temperature Reduce ambient too high temperature if possible Deficient cooling Improve cooling Item no. 16023-5-9970 · ENU · Change 202174 · Approved 2018-12-27 · Page 9 / 11 ebm-papst Mulfingen GmbH & Co. KG · Bachmühle 2 · D-74673 Mulfingen · Phone +49 (0) 7938 81-0 · Fax +49 (0) 7938 81-110 · info1@de.ebmpapst.com · www.ebmpapst.com A2E200-AH86-75 Operating instructions In the event of further malfunctions, contact ebm-papst. 5.1 Cleaning To ensure a long service life, check the fans regularly for proper operation and soiling. The frequency of checking is to be adapted accordingly depending on the degree of soiling. DANGER Risk of injury from rotating fan. → Only clean when not in motion. Interrupt the power supply, secure against renewed switch-on. Secure against start-up, prevent air flow. ; Dirt deposits on the motor housing can cause overheating of the motor. ; Soiling of the impeller can cause vibration that will shorten the service life of the fan. Fastening the cables Fastening the protective earth terminal Insulation of cables for damage Condensation drainage holes for clogging, where necessary Welds for crack formation Abnormal bearing noise Fasten Visual inspection At least every 6 months Replace cables Visual inspection At least every 6 months Open holes Visual inspection At least every 6 months acoustic At least every 6 months Replace device Fasten Replace device ; Severe vibration can destroy the fan. 5.3 Disposal ; In such cases, switch off the fan immediately and clean it. For ebm-papst, environmental protection and resource preservation are top priority corporate goals. ebm-papst operates an environmental management system which is certified in accordance with ISO 14001 and rigorously implemented around the world on the basis of German standards. Right from the development stage, ecological design, technical safety and health protection are fixed criteria. The following section contains recommendations for ecological disposal of the product and its components. ; The preferred method of cleaning is dry cleaning, e.g. using compressed air. ; Do not use aggressive cleaning agents! NOTE Damage to the device during cleaning Malfunction possible → Do not clean the device using a water jet or high-pressure cleaner. → Do not use any acid, alkali or solvent-basedcleaning agents. 5.3.1 Country-specific legal requirements NOTE Country-specific legal requirements Always observe the applicable country-specific legal regulations with regard to the disposal of products or waste occurring in the various phases of the life cycle. The corresponding disposal standards are also to be heeded. → Do not use any pointed or sharp-edged objects for cleaning ; Completely remove any cleaning agents used. ; If severe corrosion is visible on load-bearing or rotating parts, switch off the device immediately and replace it. ; Repair of load-bearing or rotating parts is not permitted! ; Operate the fan for 2 hours at maximum speed so that any water that has ingressed can evaporate. ; If cleaning does not eliminate vibrations, the fan may need to be rebalanced. To have it rebalanced, contact ebm-papst. Translation of the original operating instructions Visual inspection At least every 6 months Visual inspection At least every 6 months ; The fan is equipped with maintenance-free ball bearings. The lifetime lubrication of the ball bearings is designed for a service life of 40,000 hours. 5.3.2 Disassembly Disassembly of the product must be performed or supervised by qualified personnel with the appropriate technical knowledge. The product is to be disassembled into suitable components for disposal employing standard procedures for motors. WARNING Heavy parts of the product may drop off. Some of the product components are heavy. These components could drop off during disassembly. This can result in fatal or serious injury and material damage. ; If bearing replacement is necessary after that period, contact ebmpapst. ; Adapt the maintenance intervals to the actual level of dust exposure. 5.2 Safety inspection What to check Contact protection cover for intactness or damage Device for damage to blades and housing How to check How often Visual inspection At least every 6 months Visual inspection At least every 6 months → Secure components before unfastening to stop them falling. 5.3.3 Component disposal What action? Repair or replacement of device Replacement of device The products are mostly made of steel, copper, aluminum and plastic. Metallic materials are generally considered to be fully recyclable. Separate the components for recycling into the following categories: ● Steel and iron ● Aluminum ● Non-ferrous metal, e.g. motor windings ● Plastics, particularly with brominated flame retardants, in accordance with marking ● Insulating materials ● Cables and wires ● Electronic scrap, e.g. circuit boards Item no. 16023-5-9970 · ENU · Change 202174 · Approved 2018-12-27 · Page 10 / 11 ebm-papst Mulfingen GmbH & Co. KG · Bachmühle 2 · D-74673 Mulfingen · Phone +49 (0) 7938 81-0 · Fax +49 (0) 7938 81-110 · info1@de.ebmpapst.com · www.ebmpapst.com A2E200-AH86-75 Operating instructions Only ferrite magnets and not rare earth magnets are used in external rotor motors from ebm-papst Mulfingen GmbH & Co. KG. ; Ferrite magnets can be disposed of in the same way as normal iron and steel. Electrical insulating materials on the product, in cables and wires are made of similar materials and are therefore to be treated in the same manner. The materials concerned are as follows: ● Miscellaneous insulators used in the terminal box ● Power cables ● Cables for internal wiring ● Electrolytic capacitors Dispose of electronic components employing the proper procedures for electronic scrap. Translation of the original operating instructions → Please contact ebm-papst for any other questions on disposal. Item no. 16023-5-9970 · ENU · Change 202174 · Approved 2018-12-27 · Page 11 / 11 ebm-papst Mulfingen GmbH & Co. KG · Bachmühle 2 · D-74673 Mulfingen · Phone +49 (0) 7938 81-0 · Fax +49 (0) 7938 81-110 · info1@de.ebmpapst.com · www.ebmpapst.com
A2E200-AH86-75 价格&库存

很抱歉,暂时无法提供与“A2E200-AH86-75”相匹配的价格&库存,您可以联系我们找货

免费人工找货
A2E200-AH86-75
  •  国内价格 香港价格
  • 1+1953.219821+234.54548
  • 10+1799.0385610+216.03117
  • 25+1683.3865925+202.14352
  • 50+1657.6842550+199.05714

库存:5