AC axial fan
A2E300-AC47-01
straight blades (A series)
ebm-papst Mulfingen GmbH & Co. KG
Bachmühle 2 · D-74673 Mulfingen
Phone +49 7938 81-0
Fax +49 7938 81-110
info1@de.ebmpapst.com
www.ebmpapst.com
Limited partnership · Headquarters Mulfingen
Amtsgericht (court of registration) Stuttgart · HRA 590344
General partner Elektrobau Mulfingen GmbH · Headquarters Mulfingen
Amtsgericht (court of registration) Stuttgart · HRB 590142
Nominal data
Type
A2E300-AC47-01
Motor
M2E068-EC
Phase
1~
1~
1~
1~
Nominal voltage
VAC
230
230
230
230
Frequency
Hz
50
60
60
60
Method of obtaining data
fa
fa
fa
fa
Valid for approval/standard
CE
CE
UL
CSA
Speed (rpm)
min-1
2650
2900
2900
2900
Power consumption
W
140
190
200
200
Current draw
A
0.62
0.83
0.88
0.88
Capacitor
µF
5
5
5
5
Capacitor voltage
VDB
400
400
400
400
Capacitor standard
S0 (CE)
S0 (CE)
UL
UL
Max. back pressure
Pa
150
150
150
150
Max. back pressure
in. wg
0.6
0.6
0.6
0.6
Min. ambient temperature
°C
-25
-25
-25
-25
Max. ambient temperature
°C
55
50
50
50
ml = Max. load · me = Max. efficiency · fa = Free air · cs = Customer specification · ce = Customer equipment
Subject to change
Data according to Commission Regulation (EU) 327/2011 (prEN 17166)
01 Overall efficiency ηes
%
Actual
Req. 2015
32.2
28.7
09 Power consumption Pe
kW
0.16
02 Measurement category
A
09 Air flow qv
m³/h
1760
03 Efficiency category
Static
09 Pressure increase pfs
Pa
107
10 Speed (rpm) n
min-1
2575
04 Efficiency grade N
43.5
05 Variable speed drive
No
40
11 Specific ratio*
1.00
* Specific ratio = 1 + p / 100 000 Pa
Data obtained at optimum efficiency level.
fs
The efficiency values displayed for achieving conformity with the Ecodesign Regulation EU 327/2011 has been reached with defined air duct components (e.g. inlet rings).
The dimensions must be requested from ebm-papst. If other air conduction geometries are used on the installation side, the ebm-papst evaluation loses its validity/the conformity must be confirmed again.
The product does not fall within the scope of Regulation (EU) 2019/1781 due to the exception specified in Article 2 (2a) (motors completely integrated into a product).
LU-199188
Item no. 11071-5-9980 · ENU · Change 270821 · Approved 2022-10-27 · Page 1 / 5
ebm-papst Mulfingen GmbH & Co. KG · Bachmühle 2 · D-74673 Mulfingen · Phone +49 (0) 7938 81-0 · Fax +49 (0) 7938 81-110 · info1@de.ebmpapst.com · www.ebmpapst.com
AC axial fan
A2E300-AC47-01
straight blades (A series)
Technical description
Weight
2.57 kg
Size
300 mm
Motor size
68
Rotor surface
Painted black
Blade material
Sheet steel, painted black
Number of blades
5
Airflow direction
V
Direction of rotation
Counterclockwise, viewed toward rotor
Degree of protection
IP44; installation- and position-dependent as per EN 60034-5
Insulation class
"B"
Moisture (F) / Environmental (H)
protection class
H1
Max. permitted ambient temp.
for motor (transport/storage)
+80 °C
Min. permitted ambient temp. for
motor (transport/storage)
-40 °C
Installation position
Shaft horizontal or rotor on bottom; rotor on top on request
Condensation drainage holes
On rotor side
Mode
S1
Motor bearing
Ball bearing
Touch current according to IEC
60990 (measuring circuit Fig. 4,
TN system)
< 0.75 mA
Motor protection
Thermal overload protector (TOP) internally connected
With cable
Variable
Protection class assignment
I; If a protective earth is connected by the customer
This component for installation may have several local protection classes. This
information relates to this component’s basic design.
The final protection class is based on the component’s intended installation and
connection.
Conformity with standards
EN 60335-1; CE
Approval
CCC; EAC
Item no. 11071-5-9980 · ENU · Change 270821 · Approved 2022-10-27 · Page 2 / 5
ebm-papst Mulfingen GmbH & Co. KG · Bachmühle 2 · D-74673 Mulfingen · Phone +49 (0) 7938 81-0 · Fax +49 (0) 7938 81-110 · info1@de.ebmpapst.com · www.ebmpapst.com
AC axial fan
A2E300-AC47-01
straight blades (A series)
Product drawing
1
Cable PVC 4G 0.5 mm², 4x crimped splices
2
Direction of air flow "V"
Connection diagram
U1
blue
PE
green/yellow
Z
brown
U2
black
Item no. 11071-5-9980 · ENU · Change 270821 · Approved 2022-10-27 · Page 3 / 5
ebm-papst Mulfingen GmbH & Co. KG · Bachmühle 2 · D-74673 Mulfingen · Phone +49 (0) 7938 81-0 · Fax +49 (0) 7938 81-110 · info1@de.ebmpapst.com · www.ebmpapst.com
AC axial fan
A2E300-AC47-01
straight blades (A series)
120
in. wg
0.5
Pa
Curves: Air performance 50 Hz
4
ρ = 1.15 kg/m³ ± 2 %
Measurement: LU-66600-1
0.4
100
Air performance measured according to ISO
5801 installation category A. For detailed
information on the measurement setup,
contact ebm-papst. Intake sound level:
Sound power level according to ISO 13347 /
sound pressure level measured at 1 m
distance from fan axis. The values given are
valid under the specified measuring
conditions and may vary due to conditions of
installation. For deviations from the standard
configuration, the parameters have to be
checked on the installed unit.
3
0.3
80
0.2
60
2
0.1
40
pfs
20
0
qv
200
400
400
600
800
800
1200
1000
1600
1
1200
1400
2000
2400
cfm
m³/h
Measured values
Wired
U
f
n
Pe
I
qV
pfs
qV
pfs
V
Hz
min-1
W
A
m3/h
Pa
cfm
in. wg
1
1~
230
50
2650
140
0.62
2435
0
1435
0.00
2
1~
230
50
2610
151
0.66
2175
40
1280
0.16
3
1~
230
50
2580
158
0.69
1855
80
1090
0.32
4
1~
230
50
2565
161
0.70
1300
120
765
0.48
Wired = Wiring · U = Voltage · f = Frequency · n = Speed (rpm) · Pe = Power consumption · I = Current draw · qV = Air flow · pfs = Pressure increase
Item no. 11071-5-9980 · ENU · Change 270821 · Approved 2022-10-27 · Page 4 / 5
ebm-papst Mulfingen GmbH & Co. KG · Bachmühle 2 · D-74673 Mulfingen · Phone +49 (0) 7938 81-0 · Fax +49 (0) 7938 81-110 · info1@de.ebmpapst.com · www.ebmpapst.com
AC axial fan
A2E300-AC47-01
straight blades (A series)
120
in. wg
4
0.5
Pa
Curves: Air performance 60 Hz
ρ = 1.15 kg/m³ ± 2 %
Measurement: LU-66601-1
0.4
100
Air performance measured according to ISO
5801 installation category A. For detailed
information on the measurement setup,
contact ebm-papst. Intake sound level:
Sound power level according to ISO 13347 /
sound pressure level measured at 1 m
distance from fan axis. The values given are
valid under the specified measuring
conditions and may vary due to conditions of
installation. For deviations from the standard
configuration, the parameters have to be
checked on the installed unit.
3
0.3
80
60
0.2
2
0.1
40
pfs
20
0
400
qv
500
800
1000
1
1200
1500
2000
2500
cfm
m³/h
Measured values
Wired
U
f
n
Pe
I
qV
pfs
qV
pfs
V
Hz
min-1
W
A
m3/h
Pa
cfm
in. wg
1
1~
230
60
2900
190
0.83
2700
0
1590
0.00
2
1~
230
60
2860
205
0.90
2370
50
1395
0.20
3
1~
230
60
2800
213
0.93
2035
90
1195
0.36
4
1~
230
60
2750
218
0.95
1550
130
915
0.52
Wired = Wiring · U = Voltage · f = Frequency · n = Speed (rpm) · Pe = Power consumption · I = Current draw · qV = Air flow · pfs = Pressure increase
Item no. 11071-5-9980 · ENU · Change 270821 · Approved 2022-10-27 · Page 5 / 5
ebm-papst Mulfingen GmbH & Co. KG · Bachmühle 2 · D-74673 Mulfingen · Phone +49 (0) 7938 81-0 · Fax +49 (0) 7938 81-110 · info1@de.ebmpapst.com · www.ebmpapst.com
很抱歉,暂时无法提供与“A2E300-AC47-01”相匹配的价格&库存,您可以联系我们找货
免费人工找货