0
登录后你可以
  • 下载海量资料
  • 学习在线课程
  • 观看技术视频
  • 写文章/发帖/加入社区
会员中心
创作中心
发布
  • 发文章

  • 发资料

  • 发帖

  • 提问

  • 发视频

创作活动
A2E300-AC47-01

A2E300-AC47-01

  • 厂商:

    EBMPAPST(依必安派特)

  • 封装:

    插件

  • 描述:

    风扇 管轴式 230VAC 圆形 - 300mm 直径 滚珠 1437.2 CFM(40.24m³/min) 4 引线

  • 数据手册
  • 价格&库存
A2E300-AC47-01 数据手册
AC axial fan A2E300-AC47-01 straight blades (A series) ebm-papst Mulfingen GmbH & Co. KG Bachmühle 2 · D-74673 Mulfingen Phone +49 7938 81-0 Fax +49 7938 81-110 info1@de.ebmpapst.com www.ebmpapst.com Limited partnership · Headquarters Mulfingen Amtsgericht (court of registration) Stuttgart · HRA 590344 General partner Elektrobau Mulfingen GmbH · Headquarters Mulfingen Amtsgericht (court of registration) Stuttgart · HRB 590142 Nominal data Type A2E300-AC47-01 Motor M2E068-EC Phase 1~ 1~ 1~ 1~ Nominal voltage VAC 230 230 230 230 Frequency Hz 50 60 60 60 Method of obtaining data fa fa fa fa Valid for approval/standard CE CE UL CSA Speed (rpm) min-1 2650 2900 2900 2900 Power consumption W 140 190 200 200 Current draw A 0.62 0.83 0.88 0.88 Capacitor µF 5 5 5 5 Capacitor voltage VDB 400 400 400 400 Capacitor standard S0 (CE) S0 (CE) UL UL Max. back pressure Pa 150 150 150 150 Max. back pressure in. wg 0.6 0.6 0.6 0.6 Min. ambient temperature °C -25 -25 -25 -25 Max. ambient temperature °C 55 50 50 50 ml = Max. load · me = Max. efficiency · fa = Free air · cs = Customer specification · ce = Customer equipment Subject to change Data according to Commission Regulation (EU) 327/2011 (prEN 17166) 01 Overall efficiency ηes % Actual Req. 2015 32.2 28.7 09 Power consumption Pe kW 0.16 02 Measurement category A 09 Air flow qv m³/h 1760 03 Efficiency category Static 09 Pressure increase pfs Pa 107 10 Speed (rpm) n min-1 2575 04 Efficiency grade N 43.5 05 Variable speed drive No 40 11 Specific ratio* 1.00 * Specific ratio = 1 + p / 100 000 Pa Data obtained at optimum efficiency level. fs The efficiency values displayed for achieving conformity with the Ecodesign Regulation EU 327/2011 has been reached with defined air duct components (e.g. inlet rings). The dimensions must be requested from ebm-papst. If other air conduction geometries are used on the installation side, the ebm-papst evaluation loses its validity/the conformity must be confirmed again. The product does not fall within the scope of Regulation (EU) 2019/1781 due to the exception specified in Article 2 (2a) (motors completely integrated into a product). LU-199188 Item no. 11071-5-9980 · ENU · Change 270821 · Approved 2022-10-27 · Page 1 / 5 ebm-papst Mulfingen GmbH & Co. KG · Bachmühle 2 · D-74673 Mulfingen · Phone +49 (0) 7938 81-0 · Fax +49 (0) 7938 81-110 · info1@de.ebmpapst.com · www.ebmpapst.com AC axial fan A2E300-AC47-01 straight blades (A series) Technical description Weight 2.57 kg Size 300 mm Motor size 68 Rotor surface Painted black Blade material Sheet steel, painted black Number of blades 5 Airflow direction V Direction of rotation Counterclockwise, viewed toward rotor Degree of protection IP44; installation- and position-dependent as per EN 60034-5 Insulation class "B" Moisture (F) / Environmental (H) protection class H1 Max. permitted ambient temp. for motor (transport/storage) +80 °C Min. permitted ambient temp. for motor (transport/storage) -40 °C Installation position Shaft horizontal or rotor on bottom; rotor on top on request Condensation drainage holes On rotor side Mode S1 Motor bearing Ball bearing Touch current according to IEC 60990 (measuring circuit Fig. 4, TN system) < 0.75 mA Motor protection Thermal overload protector (TOP) internally connected With cable Variable Protection class assignment I; If a protective earth is connected by the customer This component for installation may have several local protection classes. This information relates to this component’s basic design. The final protection class is based on the component’s intended installation and connection. Conformity with standards EN 60335-1; CE Approval CCC; EAC Item no. 11071-5-9980 · ENU · Change 270821 · Approved 2022-10-27 · Page 2 / 5 ebm-papst Mulfingen GmbH & Co. KG · Bachmühle 2 · D-74673 Mulfingen · Phone +49 (0) 7938 81-0 · Fax +49 (0) 7938 81-110 · info1@de.ebmpapst.com · www.ebmpapst.com AC axial fan A2E300-AC47-01 straight blades (A series) Product drawing 1 Cable PVC 4G 0.5 mm², 4x crimped splices 2 Direction of air flow "V" Connection diagram U1 blue PE green/yellow Z brown U2 black Item no. 11071-5-9980 · ENU · Change 270821 · Approved 2022-10-27 · Page 3 / 5 ebm-papst Mulfingen GmbH & Co. KG · Bachmühle 2 · D-74673 Mulfingen · Phone +49 (0) 7938 81-0 · Fax +49 (0) 7938 81-110 · info1@de.ebmpapst.com · www.ebmpapst.com AC axial fan A2E300-AC47-01 straight blades (A series) 120 in. wg 0.5 Pa Curves: Air performance 50 Hz 4 ρ = 1.15 kg/m³ ± 2 % Measurement: LU-66600-1 0.4 100 Air performance measured according to ISO 5801 installation category A. For detailed information on the measurement setup, contact ebm-papst. Intake sound level: Sound power level according to ISO 13347 / sound pressure level measured at 1 m distance from fan axis. The values given are valid under the specified measuring conditions and may vary due to conditions of installation. For deviations from the standard configuration, the parameters have to be checked on the installed unit. 3 0.3 80 0.2 60 2 0.1 40 pfs 20 0 qv 200 400 400 600 800 800 1200 1000 1600 1 1200 1400 2000 2400 cfm m³/h Measured values Wired U f n Pe I qV pfs qV pfs V Hz min-1 W A m3/h Pa cfm in. wg 1 1~ 230 50 2650 140 0.62 2435 0 1435 0.00 2 1~ 230 50 2610 151 0.66 2175 40 1280 0.16 3 1~ 230 50 2580 158 0.69 1855 80 1090 0.32 4 1~ 230 50 2565 161 0.70 1300 120 765 0.48 Wired = Wiring · U = Voltage · f = Frequency · n = Speed (rpm) · Pe = Power consumption · I = Current draw · qV = Air flow · pfs = Pressure increase Item no. 11071-5-9980 · ENU · Change 270821 · Approved 2022-10-27 · Page 4 / 5 ebm-papst Mulfingen GmbH & Co. KG · Bachmühle 2 · D-74673 Mulfingen · Phone +49 (0) 7938 81-0 · Fax +49 (0) 7938 81-110 · info1@de.ebmpapst.com · www.ebmpapst.com AC axial fan A2E300-AC47-01 straight blades (A series) 120 in. wg 4 0.5 Pa Curves: Air performance 60 Hz ρ = 1.15 kg/m³ ± 2 % Measurement: LU-66601-1 0.4 100 Air performance measured according to ISO 5801 installation category A. For detailed information on the measurement setup, contact ebm-papst. Intake sound level: Sound power level according to ISO 13347 / sound pressure level measured at 1 m distance from fan axis. The values given are valid under the specified measuring conditions and may vary due to conditions of installation. For deviations from the standard configuration, the parameters have to be checked on the installed unit. 3 0.3 80 60 0.2 2 0.1 40 pfs 20 0 400 qv 500 800 1000 1 1200 1500 2000 2500 cfm m³/h Measured values Wired U f n Pe I qV pfs qV pfs V Hz min-1 W A m3/h Pa cfm in. wg 1 1~ 230 60 2900 190 0.83 2700 0 1590 0.00 2 1~ 230 60 2860 205 0.90 2370 50 1395 0.20 3 1~ 230 60 2800 213 0.93 2035 90 1195 0.36 4 1~ 230 60 2750 218 0.95 1550 130 915 0.52 Wired = Wiring · U = Voltage · f = Frequency · n = Speed (rpm) · Pe = Power consumption · I = Current draw · qV = Air flow · pfs = Pressure increase Item no. 11071-5-9980 · ENU · Change 270821 · Approved 2022-10-27 · Page 5 / 5 ebm-papst Mulfingen GmbH & Co. KG · Bachmühle 2 · D-74673 Mulfingen · Phone +49 (0) 7938 81-0 · Fax +49 (0) 7938 81-110 · info1@de.ebmpapst.com · www.ebmpapst.com
A2E300-AC47-01 价格&库存

很抱歉,暂时无法提供与“A2E300-AC47-01”相匹配的价格&库存,您可以联系我们找货

免费人工找货