Product Data Sheet AC 3200 JHU
The engineer's choice
Product Data Sheet AC 3200 JHU
AC 3200 JHU
INDEX
1
General ...................................................................................................................................................................... 3
2
Mechanics ................................................................................................................................................................. 3
2.1
2.2
3
Operating Data ......................................................................................................................................................... 5
3.1
3.2
3.3
3.4
3.5
3.6
4
General .............................................................................................................................................................. 8
Climatic requirements*) ..................................................................................................................................... 8
Safety ........................................................................................................................................................................ 9
5.1
5.2
6
Operating Data - Electrical Interface - Input ...................................................................................................... 5
Electrical Operating Data .................................................................................................................................. 5
Operating Data - Electrical Interface -Output .................................................................................................... 5
Electrical Features ............................................................................................................................................. 6
Aerodynamic...................................................................................................................................................... 6
Sound Data........................................................................................................................................................ 8
Environment ............................................................................................................................................................. 8
4.1
4.2
5
General .............................................................................................................................................................. 3
Connections....................................................................................................................................................... 4
Electrical Safety ................................................................................................................................................. 9
Approval Tests .................................................................................................................................................. 9
Reliability .................................................................................................................................................................. 9
6.1
General .............................................................................................................................................................. 9
11/25/2014
page 2 of 10
Product Data Sheet AC 3200 JHU
1
General
Fan type
Rotational direction looking at rotor
Airflow direction
Bearing system
Mounting position
2
Mechanics
2.1
General
Width
Height
Depth
Diameter
Weight
Housing material
Impeller material
Fan
counterclockwise
Air outlet over struts
Ball bearing
any
92,0 mm
92,0 mm
72,0 mm
0,0 mm
0,325 kg
Plastic
Plastic
11/25/2014
page 3 of 10
Product Data Sheet AC 3200 JHU
2.2
Connections
Electrical connection
Length of lead wire
Wires
L = 450 mm
+- 10,0 mm
Tolerance
Length of tube
Tolerance
Wire gauge (AWG)
Insulation diameter
Plug
Contact
Wire 1
Wire 2
S = 15 mm
+- 5 mm
22
see drawing
see drawing
Colour
black
black
Operation
L1
L2
11/25/2014
page 4 of 10
Product Data Sheet AC 3200 JHU
3
Operating Data
3.1
Operating Data - Electrical Interface - Input
External voltage supply for input and output signals must be SELV conform.
Control input
3.2
Electrical Operating Data
Features
Voltage range
Nominal voltage
Frequency
Power consumption
Tolerance
Speed
Tolerance
3.3
None
Condition
∆p = 0
∆p = 0
∆p = 0
Symbol
U
UN
f
Values
85 V
∆p = 0
P
12 W
+- 20 %
∆p = 0
n
6.800 1/min
+- 10 %
265 V
115 V / 230 V
115 V / 230 V
50 Hz
12 W
+- 20 %
12 W
+- 25 %
60 Hz
12 W
+- 22,5 %
6.800 1/min
+- 10 %
6.800 1/min
+- 10 %
6.800 1/min
+- 10 %
Operating Data - Electrical Interface -Output
External voltage supply for input and output signals must be SELV conform.
Tacho type
None
Alarm type
None
11/25/2014
page 5 of 10
Product Data Sheet AC 3200 JHU
3.4
Electrical Features
Electronic function
Locked rotor protection
Clock signal t3/t4 at locked rotor
3.5
None
Auto restart
Typical: 0,5 s / 11 s
Aerodynamic
Measurement
conditions:
Measured with a double chamber intake rig acc. to DIN EN ISO 5801.
Normal air density = 1,2 kg/m3; Temperature 23°C +/- 3°C;
In the intake and outlet area should not be any solid obstruction within 0,5 m.
The information is only valid under the specified test conditions and may be changed by the
installation conditions. If there are deviations from the standard test conditions, the
characteristic values must be checked under the installed conditions.
a) Operation condition:
6.800 1/min at free air flow
Frequency: 50 Hz
Max. free-air flow (∆p = 0 / = max.)
Max. static pressure (∆p = max. / =0)
b) Operation condition:
6.800 1/min at free air flow
Max. free-air flow (∆p = 0 / = max.)
Max. static pressure (∆p = max. / =0)
Nominal voltage: 115 V / 230 V
144,0 m3/h
260 Pa
Frequency: 60 Hz
Nominal voltage: 115 V / 230 V
144,0 m3/h
260 Pa
11/25/2014
page 6 of 10
Product Data Sheet AC 3200 JHU
11/25/2014
page 7 of 10
Product Data Sheet AC 3200 JHU
3.6
Sound Data
Measurement
conditions:
Sound pressure level: 1 Meter distance between microphone and the air intake.
Sound power level: Acc. to DIN 45635 part 38 (ISO 10302)
Measured in a semianchoic chamber with a background noise level of Lp(A) < 5 dB(A)
For further measurement conditions see section 3.4
a) Operation condition:
6.800 1/min at free air flow
Frequency: 50 Hz
Optimal operating point
92,0 m3/h @ 100 Pa
Sound power level at the optimal operating
point
Sound pressure level at free air flow,
measured in rubber bands
6,4 bel(A)
b) Operation condition:
6.800 1/min at free air flow
55,0 dB(A)
Frequency: 60 Hz
Optimal operating point
92,0 m3/h @ 100 Pa
Sound power level at the optimal operating
point
Sound pressure level at free air flow,
measured in rubber bands
6,4 bel(A)
4
Environment
4.1
General
Min. permitted ambient temperature TU min.
Max. permitted ambient temperature TU max.
Min. permitted storage temperature TL min.
Max. permitted storage temperature TL max.
4.2
Nominal voltage: 115 V / 230 V
Nominal voltage: 115 V / 230 V
55,0 dB(A)
-20 °C
70 °C
-40 °C
80 °C
Climatic requirements*)
IP-protection type (certified)
Humidity requirements
IP 65 (for fan only, not for connector if applicable) **)
humid temperature, cyclic; according to DIN EN
60068-2-38, 10 cycle and condensation water
check; according to DIN EN ISO 6270-2, 14 days
Radiation exposure
Salt fog requirements
Harmful gas requirements
Solar radiation; according to DIN EN 60068-2-5
None
None
*) Permittet application area:
The product is for the use in partial sheltered rooms or open, roofed areas. Direct exposure to water is allowed
provided that this does not prevent the normal operation. Saline ambient conditions must be avoided.
Pollution degree 3 (according DIN EN 60664-1)
It occurs conductive pollution or dry non-conductive pollution which becomes conductive due to condensation.
11/25/2014
page 8 of 10
Product Data Sheet AC 3200 JHU
**) The specification of the IP protection refers to the conditions mentioned in certification of the fan. The above
mentioned short description of the protection scope is not final. For detailed information of the respective protection
scope and definitions, see certification as well as DIN EN 60529 (protection by housings) and ISO 20653 (for vehicles)
with the letter K.
Short description of the IP-protection type:
Solid particle Protection: Dust tight.
Protection against deliberate contact: Protected against contact to hazardous parts with a wire.
Protection against water: Protected against water jets.
5
Safety
5.1
Electrical Safety
A verification of thermal conditions (normal and abnormal operation) as well as the protection against electric shock,
ingress of solid foreign objects and water has to be done in conjuction with the appliance.
Test voltage HV type test
Unit test voltage
Time type test HV
Insulation resistance
Protection class
5.2
1500 V
VAC
1s
RI > 10 MOhm
built-in fan
Approval Tests
CE
UL
VDE
CSA
CCC
Yes
Yes
Yes
Yes
Yes
According to the guidelines on the application of Directive 2006/95/EC, chapter III: Scope of the "low voltage" directive,
paragraph: Are "components" included in the scope? the following has to be applied:
However, some types of electrical devices, designed and manufactured for being uses as basic components to be
incorporated into other electrical equipment, are such that their safety to a very large extent depends on how they are
integrated into the final product and the overall characteristics of the final product. These basic components include
electronic and certain other components.
Taking into account these objectives of the "Low Voltage" Directive, such basic components, the safety of which can
only, to a very large extend, be assessed taking into account, how they are incorporated and for which a risk
assessment cannot be undertaken, then they are not covered as such by the Directive. In particular, they must not be
CE marked unless covered by other Community legislation that requires CE marking.
6
Reliability
6.1
General
Life expectancy L10 at TU = 40 °C
Life expectancy L10 at TU max.
70.000 h
35.000 h
11/25/2014
page 9 of 10